Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D98-0191 - METROPOLITAN HARDWOOD - WALL
D98 -0191 1130 Industry Dr. Metropolitan Hardwood City of Tukwila i. Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 252304 -9071 Address: 1130 INDUSTRY DR Suite No: Location: Category: AWSE Type: DEVPERM Zoning: CM Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: W Contractor License No: PAULSBRO44JJ METROPOLITAN HARDWOOD 1130 INDUSTRY DR, TUKWILA WA 98188 PACIFIC GULF PROPERTIES 631 STRANDER BLVD, TUKWILA WA 98188 PAUL STEPHENS 22401 100 AV SE, KENT WA 98031 PAUL STEPHENS BLDG & PLUMBING 22401 100 AV SE, KENT WA 98031 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: 60 LF NEW NON- STRUCTURAL WALL. **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 1,600.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time:: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 89.06 r******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** OCCUPANT OWNER CONTACT CONTRACTOR Permit Center Authorized Signature:_ Signature WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. DEVELOPMENT PERMIT Fire .0 South: .0 East: Sewer: TUKWILA Slopes: Y Permit No: Status: Issued: Expires: Occupancy: UBC: Protection: .0 West: Streams: 2 Phone: (206)575 -0765 Phone: 206 650 -4475 Phone: 206 - 650 -4475 Size(in): .00 End Time: Fill: (206) 431 -3670 D98 -0191 ISSUED 06/17/1998 12/14/1998 WAREHOUSE 1994 AFA .0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development emit. Date: Z-/ � Print Name:_44W4__S4gb This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 1330 INDUSTRY: DR Suite. Tenant: Status: ISSUED Tune : DEVPERM APp l i ed : 0603: 1993 Parte1 #: 252304 -9071 • Issued: 06/17%1 •k• k*: k****.• k**' k' k• k- k• k•k*****• k*** k**• k• k******: k* k; kk k******* k• k*• k kkk ^k•k *•k`•k *'k*"•k Perini :t Conditions: 1 . No chanueS " wi 11 be. made to the .plans unless approved ;Tukwila 'Building Division. 'Electrical permits Sha11 be5ahta.itrei t1liquoh" `the..Washington: 'state Division of Labo and 'tndustr ies anti X4¢1 electrical w�: rk wi 11 be :ins.07ege d b t aoei cy ('4248' } Al 1 mechen i £ha 41 be; Cinder' seuar ,te per.hi'' " issued , 1)9: the Ci tat Tu a�i la.. ))SL : wia • 4r Pl umlr' ua pei,m°its t, h :a1 1„ Lie _ obte ned tt 1e, i 7rira` . County DeD,, rtment Hof., pub ir`'Mecbi "th`: ' 4 Paumb inc i wi l,�t•;.. in :liet:ted by that,acencyv in,c,l,udinc( all gas piDing� (296-4,7 . 5'. 'All pet rit. in .pection;:riectrds. a +d approved' Dlar st;sha avai laikh'l the `mob n i or to the start of ; any con tr u ` e f ] . ) on w ' f Thee documents \ar a rto be ma i rita inett an ,a-va h 1 efiun na`1 ins va -i . i s gran • A l tyCbniSt r uc tton to 6'e" `d one;'`:,xn • •conf r :mance wi th appr °V*, p1 rl.s "a C-'e tlui renents''o the,Unitor?m Ruiw1 C ode; (1994 :_ s Ed as amended, tin 1 ti ni lit } echanie'al Code (1 E tii ; tion a�};ci �Ja h�ngton ,';3 tat;e Ener a t 1' 4 Eciition) { r, `Jal °o' Peissuance of a °t5 ritrit r ..aDLIroval pl'ans". S pec.. i t�;i.cat i ons,', +• ,and comput i o oni ohm l 1 . not be "con �r to °"be ,,a permit" to,r. •an approval of any, :vjolat,tl n of al ?v of ; pr ovi>oions -or g` or• arty others or °dliia of the iurisdic +un No' mit presunrina' aive,i: au ~ {itv`,,to violate or car,uel: the r . -p 6vi Qn'sr ' t"'t trs 1 code: hal�i';.be vat i�d• r j S • t ;` • Project Name/Tenant: IY1 LTAr)pm._i - -v4 ikA IDWoop Existing use: ❑ Retail ❑ Restaurant ❑ Multi - family aWarehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel P Office ❑ School /College /University ❑ Other Value of Construction: /6 Tax Parcel Number: ,,Zs - qv7 / -05 Site Address: City State /Zip: tI3D Ir6DL1.51 RV PR) LIE - fl)1;k0/..-A /NA ' ? ?/kY/ Property Owner: r, 41' / FI L- 66I1-1: ?FP tz' - g_77 ,5 /jJ C . Will there be rack storage? ❑ yes 71. no Phone: D 6 - S 75 7� S Building Square Feet: 7 �O o existing Street Address: / (c ( 5 iTP ni /Paz_ 73I.. V/ 7 G i0/ City State /Zip: u1/47 elf /5f Fax #: ,2 v L - 5 0 7; Contractor: ''7 /7 - ft/ pc {: c,,/ Phone: ZG - 6s0-_ c, 97s Street Address: ZL 'o / 1L7 t/I v -C z . Wit, ti/Lt . City State /Zip: 9,9 Fax #: 2S17 - ..C S 7 S Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Cogtact Person: /` ./A:// c/ • i! // , ;wwi Phone: • Street Address: f 1 . 1 Y r ) r / .S T k P. /; lata• /90,7; City State /Zip: Fax #: Description of work to be done: 6 U L F NEW tl ok 5 7Ruertil Gl e- Gf/1-ta_ Existing use: ❑ Retail ❑ Restaurant ❑ Multi - family aWarehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel P Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family 74 Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ® Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes 4 no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 71. no Existing fire protection features: ❑ sprinklers 7_ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 7 �O o existing Area of Construction: (sq. ft.) ('O Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. CTPERMIT.DOC 1/29/97 APPLICANT REQUEST FOR PUBLIC WORKS; SITE /CIVIL:PLANFREVIEW'OF THE FOLLOWIN (Additional reviews may be defermined:by the:Public Works Departmen ''' <' ':: ❑ Flood Control Zone ❑ Hauling ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #t: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #t: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s)• ❑ Water Meter Temp # Size(s): Est. quantity: gal ❑ Miscellaneous Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale application accepted: ()- 5-1'6 Dale application expires: Appllcajlo aken by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AUTHORIZED AGENT: Signature: ` - " 6 ' J . " /! -1C: Date: s b S jC1� I Print nam ©. ,1 {k ll 1 I f1 t_.l bl) C' IC v 5 7 s-.„ U �4, S-- F ..0 n • 5 ? S ' 6 ?2/ Address (� 3 / 7 i ` t �/ � , c= "�2 /-5.4 Vl� City /State /Zip i _rciv.. kl ? /r(8",) ALL COMMERCIAL/MULTI-WILY TENANT IMPROVEMENT /A RATION PERMIT APPLICATIONS A4 T BE SUBMITTED WITH THE FO OWING: ➢ , ALL DRAVI/I(�iIGS T6 BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STJWCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN );> BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ 0 Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ y Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ © Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ W Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ in Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of itl Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) El Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 Pe rmit o D9R-011. Ivbe: DEVPERM DEVELOPMENT PERMIT Parcel No: 25230967i SiteAd.dress.: - 1130 INDUSTRY DR foti Fees: - 13q 0(, This Pavment 55.75 Totel ALL Pmt Balance: - 00 4 ****4.,‘k4.8**A*18.4**.otitoi.,8,8A4.****..,8*.k.Ai-AA.44.ii„,8AA,84***.akAl,A*-4.**Aly* . . • Account Code . Description Amount: 000/322,100 BUILDINCI- NO • 51 25 000/366.904 STATE BUILDING • „. • : CITY OF:TUKWILA.' NA * TRANSMIT Numberl R97.00780 Amourtt. 55 75 0 Pavment Method: 42HECK Notation :PAUL STEPHENS '.. AA:4:k *:b*41:*kA** •AkA** *A*A** , A: F• A: 4hk k• A•kk +k k4#k•k•k•AkA4•Ak:4k•kfi* * *4 **• {e. CITY Or TUKWILA. .WA TRAN"Nl•1' :P :± kk Aki,k A• hAk. A.AJ.* A k• A• hA• k, bAkk: kk " F: A• kkkAk *k*i c. A: 4kk k: l: lek *Ak*1- 41A•4k•k TRANSMIT Number: P970077 Amount: 33.31. 0t; /03/U1 08:38 Pavment Method: CHECK Notation: .PAUL STEPHENS Init: 13t H P,ei mit NJo:. 098 -0191 Tvpe: t}EVPERM DEVELOPMENT PERi4I't;. Parcel No: 252304 -907i. Site 'Address: • 1130 INDUSTRY DR .t•.otal ..eesw :.100 This. Parvment ' 33w,31 Total taLL' Pmts: '`3341,'. .8 a.l anoe : ";5.;75 :.• k• kA* tk . AA' AA• bAAkAA1 a .A•AA•k-A.kAA'k % *:A•Ato kA** A. 42t *IVies1t*Ik.AitA•.lhkVie•kfi, . Account . Code I?esarl ot.•i on Amau'nt 0a0/345.Y830 PLAN CFIECK .- NONRES 33.3J. .. ject: i ce A • ! %( T se of • section. 11 AO .." _ .. . � ,�� Special instructions : \ / W�/t... w 'L / `( Date =IsI�J/ r Re•r er: l . o l i ./— / 'r7 r 4 ' INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF Tt1KWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9 PERMIT NO. 431 -3670 COMMENTS: �c+ Approved per applicable codes. Corrections required prior to approval. v $47.00 REINSPECTION r REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: Receipt No: P o ect: (( j e`kY U AG vC\Wd19 el Type of Inspec 'on: r l vNtn ddress: r Date called: Special instructions: Calk -.∎ { 5 j� f Q vl VQ 5 r 1 1�c; s-e rwAt 1 T' Date wanted: D-060 . •--7) Requester } Tayl Phone: c )_Glo- to SO- 1 -1 1 r,S INSPECTION NO. Approved per applicable codes. Receipt No: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: 1 $47.00 REINSPECTION F trEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. Date: INSPECTI.N NO. CITY OF TUKWILA BUILDING DIVISION 6300. Southcenter Blvd., #100, Tukwila, WA 9818 P � RPft tax0 AfIcr lt J ) o'CJ UJ - cam( `- Special- ,instructions: COMMENTS: Inspector: [l $42.00 EINSPECTItIN be paid at 6300 Southcent f Receipt No.: F r INSPECTION RECORD Retain a copy with permit Ty e of i spection: ice# A Date called: Date wanted: (206) 431 -3670 Co 0?), Request Phre, k (066 L A4 /5 Approved per applicable codes. I l Corrections required prior to approval. Date: 23- REDYJIRED, Prior to inspection, fee must Ivd., Suite 100. Call to schedule reinspection, Date: PrpjM.a 74a °t_dt J000jype of inl;pecHop;, L 113GV v, Acittm r U ,` . /' Date called: „ ici Special�:insttr 1 Date wanted: • { �/.1�11. � Re uJ - � 1.� Ph o GI ' -75 1 INSPECTION RECORD -C' ` (� I Retain a copy with permit dr $� �� L 1 . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 PERMIT NO. (206) 431 -3670 ig ...Approved per applicable codes. COMMENTS: l I Inspecto Corrections required prior to approval. Date: 6P.7 F - 1 $42.00 REINSPECTI ' FEE • ECUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. I Receipt No.: Date: Project / v 4 &v/ o/4 1 1 T of inspect • nY ° Ad ess. //30 _ I. .-17 ,AL, Date call- .. "Speciai,,i{tstructions: Date wanted: Requester: Phone No.: zo INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 1 Approved per applicable codes. X] Corrections required prior to approval. COMMENTS: ,.(4/1111.41 $42.0 a REINSPECTIO ' FEE REQUIRED. Inspector: INSPECTION RECORD Retain a copy with permit be paid at 6300 Southcenter Blvd., Suite 100. Date: CJ9:5 9/ PERMIT NO. GHCa�ta2!4{F.�yrl� {GL�s,;�r�?"} (206) 431 -3670 Prior to inspection, fee must CaII to schedule reinspection, Receipt No.: Date: Fir YPe of innti A ,,,, AfG opoulI //79, zt ooT A / ijoi j �, al - , �/� f _ Date called: 1 . 7 jf r ' Date wanted: p.m. R `?a s er: � L 5p,us Ph • &)4,5o h/ 75 10 COMMENTS: Receipt No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. "%+ 7� T. esi�S ^...Nci�'Ftia¢.teV+�s'y�.oari �p,�e�rl ems .;srvd >iivrnM�:�',tir..vtivcn..' INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. Date: VI? -0191 PERMIT NO. (206) 431 -3670 $42.00 REINSPECTIO " FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, CaII to schedule reinspection. C , 7.7-MT,MM-MM trWMPTAMAirr --: '11C P 7! 24MR757 . 07,; City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Proj ect Name /4 e-fvo ez,/ ;44 // 61 4 Address Retain current inspection schedule Needs shift inspection x Approved without correction notice Approved with correction notice issued Sprinklers: / Fire Alarm: / Hood & Duct: / Halon: / Monitor: Pre-Fire: Permits: Authorized Sign ture FINALAPP .FRM re I Rev. 2/19/98 • Permit No. DY4?-o/ gi •. . • Suite # fi p Date T.F.D. Form F.P. 85 Headquarters Station; 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 .. . . CITY OF TUKWILA APPROVED JUN 1 2 199 As Nom ESUILDNG DM .db N OP db q RECEIVED TY OF TUKWILA a iv PERMIT CENTER 0 EXSTING ROOF bTRUGTURE Move N3t1 SLIP JOINT NEW 1 - HOUR LbREEMAKD GELLING ASSEMBLY NEW 3V2 METAL STUDS 24" OG. SOUND BAIT INSULATION 5/8" TYPE X GWB I- HOUR FIRE-RATED I /4" RAWL PINS 32" O.C. "7- VINYL COVE I3A5E OUSTING CARPET' / ISrING CONG0.ETE F1-001t. A- WALL SECTION DEVIL DEVIL EXISTING ROOF STRUCTURE ABOVE EXISTING GW8 /rRAtA1N6 CEILING ASSEMBLY NEW 3 U2" METAL STUDS 2A "O.C. Sant BATT INSULATION 5 /e" TYPE X GWB V4'' RAWL PIIJS 31 O.C. VINYL GONE BASE IF APPUGA8LE' XISTIKIG CARPET IF' APPuc,ildLE FXISTIIYi CONCRETE FLmR WALL SECTION DETAIL SLALC I /4 I'6" EXISTING ROOF STRUCTURE AEGVE g NEW SLIP JOINT w AIv 3 112" METAL STUDS 24" O.C. w15/t3" GWB BDTH SIDESz W ABOVE EY15TING WALL ASSEMBLY c.) 1 EXISTING 3 /2 METAL STUDS 24" O.C. 5 /B" TYPE x GW6 VINYL COVE EASE I A 9 PLIGAgLE EXISTING CARPET IF APPILABLE EXISTING CONCRETE FLOCK WALL SECTION DETAIL YALE i4"-re SCALE: DATE: 1 APPROVED BY: U PAcIFis GULF 8D.SNE35 PARk. WALL SECT)ON DETAIL DRAWN BY REVISED DRAWING NUMBER IRON ROD YPC STAMPED :T 8409" "LS 8271" 6=2510'37" R = 397.24 A =174.56 CI3 =N 14'22'47 "E C = 173.15 • 1 .8 ASPHALT 51.0 120 120 12.0 0 SITUATED• IN: THE BOtOTHEAST:' :.QuARTER'.OF SECTION; 26. AND :, THE:• SOUTHWEST '. . QUARTER SECTION. 25, •TOWNSHIP :23 :NORTH; RA■GE:4• EAST WILLAMETTE MERIDIAN, CITY OF TUKWILA, ,KING :COIJNTY,:WASHINGTON,•AND BEING DESCRIBED . AS 'FOLLOWS :. BEGINNING AT A POtNT WHICH.IS SOUTH 01'47'28 ";' WEST, A.•DISTANCE : .OF 1340.68 FEET AND NORTH 88,'1 "•WEST,' PARALLEL .WITH : AND 2.1.00 :FEET•.SOUTI•l 'OF •THE CENTERLINE OFP- 17•. DRAINAGE. CHANNEL. A: FROM :THE' EAST QUARTER 'CORNER OF . SAID: SECTION: 26 °AND.THE•.WEST•• :QUARTER CORNER:OF SAID SECTION • 25 • AND RUNNING,THENCE :,•SOUTH ; 8812'32 ",:.'EAST; - PARALLEL WITH AND.. . 21 :00 FEET SOUTH•OF, :'SA10'CENTERL•UNE'.OF P -17. DRAINING'CHANNEL.A DISTANCE OF. 710.00 FEET. TO , A POINT;.. THENCE• •0tr47 :28" 667.59 FEET TO.A POINT ON THE.NORTH LINE OF THAT PARCEL RECORDED AUGUST••18, 1965.' . UNDER AUDITOR'S •FILE .NO: :THENCE NORTH.• 88'12'32."•, •WEST, ON • SAID. • NORTH LINE A DISTANCE •OF 769.01• FEET TO. A• P.OINT;'THENCE. LEAVING • SAID. NORTH • LINE 'AND . RUNNING 'NORTH, 26'58'05': EAST, A. DISTANCE OF•.60.00,•FEET TO.: THE • BEGINNING OF.A.TANGENT 397.24 FOOT RADIUS CIJR1/E LEFT; THENCE :ON SAID.CURVE THROUGH A CENTRAL ANGLE, OF. 25.)O' 7',•(THE;'LONG'CHORD. •OF ,WHICH• BEARS .' NORTH • 1422'47 "'. EAST; A'.DISTANCE OF•:1•7.3.15 FEET) AN ARC DISTANCE OF 174.56 FEET.; THENCE 'NORTH 01 ° 47'28' EAST;'A DISTANCE•OF .OF ..453.35 FEET TO THE POINT OF BEGINNING, CONTAINING 10.979 ACRES MORE OR.LESS. BASIS OF BEARING BEING. THE CENTERLINE.: OF :' STRANDER BLVD. PER ;SURVEY NO 8704029002, 0 L D G 5 30 . 4' L EXHIBIT B SITE PLAN BUILDINGS 30 -42 PACIFIC GULF BUSINESS PARK - TUKWILA X 1111111111 111 111111h-- - 91111111111 - --� n r rn p Cl w D -- r � .__17 � G'' ` L. _ .rtr L..+ z CITY OF TUKWILA APPROVED JUN 1 2 1998 AS t1O' BUILDING C11C'1 ON JUN 9199$ PERMIT CENTER X , LANDLORD TENANT [ ti) ' 411 EXHIBIT B SITE PLAN BUILDINGS 30 -42 PACIFIC GULF BUSINESS PARK - TUKWILA X 1111111111 111 111111h-- - 91111111111 - --� n r rn p Cl w D -- r � .__17 � G'' ` L. _ .rtr L..+ z CITY OF TUKWILA APPROVED JUN 1 2 1998 AS t1O' BUILDING C11C'1 ON JUN 9199$ PERMIT CENTER X , LANDLORD TENANT 0 0 O 0 0 0 EXHIBIT B SITE PLAN BUILDINGS 30 -42 PACIFIC GULF BUSINESS PARK - TUKWILA CITY OF TUKWILA APPROVED JUN 1 2 1998 AS NOTED BUILDING DIVISION JUN - 31998 PERMIT CENTER X. , LANDLORD TENANT • it RXIIIBIT A FLOOR PLAN - BUILDING 38 CI TY OF l A JUN ° 31998 P ERMT a TER LANDLORD X TENANT f ; '1Z � �• CITY OF TUKWILA JUN - 3 198 pEpMiT GCNTER RECEIVED ILA January 20, 2000 Paul Stephens 22401 100 Ave SE Kent, WA 98031 1, City of Tukwila Department of Community Development RE: Permit Status D98 -0191 1130 Industry Dr Dear Mr Stephens In reviewing our current permit files, it appears that your permit for a non - structural wall, issued on June 17, 1998, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician CHAR e g - Xc: Permit File No. D98 -0191 Duane Griffin, Building Official Steven M..Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.4313670 • Fax: 206.431.3665 DEPARTMENTS: Bu' iT Division tb c GC/or'f�s [o -h-ct q DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete 0 Incomplete 0 Comments: TUES /THURS ROUTING: Routed by Staff PLAN�RE�V E Coo O TU SLIP 5 (2 Fire Prevention AU)C. (09 ( Structura Please Route 0 REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions REVIEWERS INITIALS: CORRECTION DETERMINATION: Approved 0 Approved with Conditions 0 \PR- ROUTE.DOC 6/98 ACTIVITY NUMBER: PROJECT NAME: XX Original Plan Submittal Response to Correction Letter # D98 -0191 METROPOLITAN HARDWOOD DATE: 6 -3 -98 Response to Incomplete Letter Revision After Permit Is Issued (if routed by staff, make copy to master file and enter into Sierra) PIT -ling Division 0 Permit Cooridinator DUE DATE: 6 -4 -98 Not Applicable ❑ No further Review Required DATE: DUE DATE: 7 -2 -98 Not Approved (attach comments) 0 DATE: DUE DATE: Not Approved (attach comments) 0 REVIEWERS INITIALS: DATE: 1 City of Tukwila Fire Department Fire Department Review Control #D98-0191 (512) Dear Sir: June 10, 1998 Re: Metropolitan Hardwood - 1130 Industry Drive Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) John W. Rants, Mayor Headquarters Station; 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 2 Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1- 1212.8) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112. (UFC 1207.1) 3. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 (7 . City of Tukwila Fire Department Page number 3 Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, . altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, ( The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 PAULSBR044JJ 04 /01/1999 EFFECTIVE DATE 04/11/1996 PAUL STEPHENS BLDG & RMDLNG 22401 100TH AVE SE KENT WA 98031 Signature Issued by DEPARTMENT OF LAl30R AND INDUSTRIES