Loading...
HomeMy WebLinkAboutPermit D98-0218 - CONCENTRA - OFFICE AND TELECOMMUNICATINS WIRINGD98-0218 • 545 Andover Pk. W. Concentra THIS CERTIFICATE ISSUED *eURSUAN,T rTO, THE R ,F TION 109 OF THE UNIFORM BUILDING CODE ,CEPTI T AT �TtiE TIME r; ''F 'I�'S`SUAUrE THIS' '' TRUCTUBE; WAS IN COMPLIANCE WI =TH THE, �VAP'I1lUS ORG`'I'NANW UE jTHET CIT BUILDING CONSTRUCTION OR USE rAN L L °APPLICABLE, CITY t FIRE CODES. FOR', THE FOLLOWING: O+.ccu t: CONI ENTRA' Bui 1dina Add ess: 545 ANDOVER F�ar�c i #:2 31175:; ';"Owner <'`LOWE NORTHWEST INVESTOR;; Uc .ur. ncAi: iFF:I' • CERTIFICATE OF OCCUPANCY CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD. SUITE 100 TUl WILA. WASHINGTON 93138 ` FRAME IW..'6WALL OFFICE COUSTRUCT.ION COMt,�j ICATrON'a< I,RING. ( _____ ......=====„„„.„ City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9075 Permit No: D98 -0218 Address: 545 ANDOVER PK W Status: ISSUED Suite No: 109 Issued: 07/09/1998 Location: BUILDING #1, SUITE #109 Expires: 12/27/1998 Category: AOFF Type: DEVPERM Zoning: TUC Const Type: V -N Occupancy: OFFICE Gas /Elec.: UBC: 1994 Units: 001 Fire Protection: SPRINKLER Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: N Streams: Contractor License No: SGACO * *084BS OCCUPANT CONCENTRA 545 ANDOVER PK W, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTRACTOR SGA CORPORATION Phone: 206 778 -2191 6414 204TH STREET S.W. #200, LYNNWOOD, WA 98036 CONTACT MARK BARBIERI Phone: 206 -623 -0200 600 UNIVERSITY, STE 2820, SEATTLE WA 98101 r**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: FRAME IN WALLS, OFFICE CONSTRUCTION, TELE- COMMUNICATIONS WIRING. r **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 15,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 375.34 Permit Center Authorized Signature: � _ .� Date: / k******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the perf• *i - nc -co ork. I am authorized to sign for and obtain this developme C 1 "7 �; Signature:_ Print Name: a c L-. .G 1 DEVELOPMENT PERMIT (206) 431 -3670 *********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUK:.WILA Address: 545 ANDOVER PK. W Permit No:. 098 -0218 Suite: Tenant: Status: ISSUED Type: DEVPERM Applied: 06/22/1998 Parcel #: 262304 -9075 Issued: 07/09/1998 ******* k***• k k*• k• k***************• k**• k• k****• k**• kk* k• k**• k• kk *•kk *•kk*•k•k•k * Permit Conditions: 1. No chanties will be made to the plans unless, approved by the Architect or Engineer and the Tu}wil,a Division. 2. Electrical permits; cha1:,1 be ta b�inei t hrough the Washington` State Division al „.La or. 3 ari'd""Industri e 5 an'dw ail ,, e Iectr•ical work w i l l be insDeuft+e'd by ,.that aoencv (248= 3. Al 1 mechan i ca,1":'wOr: she 11 'be.'; undeOseuarate, nerrni t issued by tr the City of/TuE,W7is 4. All per mit; ', f 'inspeotion.'record.. . and`'approv „prlan�. l : be available . at the fob site,:: prftir to” the ,tar t: anv c`an struct ion These , t1ocuments 'are .,to be ma in.ta•ined `and avai.1 - ' able 0'01 final i nspecti ari s abprrova,l ' i is granted ,.,tu 5. Any n gr,, and 'light tikture installa required ,to meet "lateral1 bracing requirements for Se;i'srni Par ' tion al is attached to ,scei l inq must be braced 11 over eight (8) feet in 1.enath. 7. Anv ,exposed insulations backing maternal Thal l have a (=Lame` S p r ead Rat;t ri'a of: -,25 or <l e ss '' and rnat�er a l ° sh;i 1 1 . bear dent i yii f icat ion showing- -the t,i, e ; ''c erfar mance;;a'rat_ina thereof : `� ;' ' j ` 8. Al I.. construction to be d ne':'In conf,ormari.ce..with' approved plans and s' l rene,nts of. the,, Un1i t•o',rm 'Building Code (199 Edition) as amendeed. Uniforni Mecha.ni`ca1, Code (1994 ,,Editiloii and Washi,n ton State 'Eneray Code 1 (1994 it.i.on). 9. Val i�di tv ,ofz' Permit. The • issuance of ` a p mi't. or aloor,aval o plan,`, Specifications, and compUtations, shal,1 not,ybe ccan - , s.truedt to, be. a permit tor. or an ap.nroval ofanv vio.1 tiun;,,” of anyof the provisions of the''build,irig code' tit' of .any, other°. ordinance of, the iurisdictiori:-, ( NO p r'nij presurning'to give a uthority, t,o Violate or cancel the pr ov th1 code shat , be vall id 10. There sha,1 1 be no; occupancy,. of this , t,enant spat of 9� until, =., t-he e final insc,t h been compl e:ted by the Tukwila B 1';1�''ding, Inspector, 11. VENTILATION IS;REWUIRED FOR" ALL, NEW RbOMS AND SRA E' OF NEW OR EXISTING BUILDING'' IN CONFORMANCE� WITH THE .U1',IFORM BUILDING CODE AND "'THE>;::WASHINGTON STATE.,.fVEN`;TILATION ANTI INDOOR AIR QUALITY CODE'. +. I�HAP<.TER �l _' X. ,,1�t Site Address: 6-715. /`i'Ot e, nek 5 4- P/€9"/ Value of Construction: $ / 3! oo& Project Name/Tenant: Co h Cek .4.. Assessor Account No.: Z 4 Z 3,01 9,07-5" (interior) 0 Other: Type of Work: Tenant Improvement 0 Demolition Describe work to be done: .41.,m , .� ()as G V 4 tex �-. - 04& 4,4nA , up,- u 1 ex Phone No.: Building Type: y-- // - Z. 516,- .. WOexO 'F'ro & Sp- �,_ _ r .� Building Use (office, warehouse, etc.): 0 le - t_c Nature of Occupancy (printing, manufacturing, etc.): el /K Will there be a change in use? 4 No 0 Yes If "yes ", explain: WA State Contractor's License No.: S &I4- Gp Square Footage - Entire Building: / y sdr.) Construction Area: / SOO Tenant Space: / do Will there be storage or use of flammable, combustible or hazardous materials in the building? Irilo 0 Yes If "yes ", explain: Architect: Ng s Property Owner: LitsqLre 4.)0 1. y ' rtive6 lebo■ PlIVateAt Phone No.: zeg 623 e zoe Address: ,;,�, s e zrzo City /State/Zip: S 044- %/0/ / Contractor5M 1,,.4.n Print Name: Uji cd . it_ rC/` ; Phone No.: Z m t Address: ` Li r y %jy' 5 7 1 5w 4/ tee City /State /Zip City /State /Zip: 01 Sd3‘ WA State Contractor's License No.: S &I4- Gp 0s+i 3 s Expiration Date: 6.q I Architect: Ng s Phone No.: ite5 Ze 3 SS'S Address: / // , , /J je.S, City/State/Zip: _ .' "k/o�m WA State Architect's License No.: 2.26 I/ Expiration Date: / Z • / / hereby certify that I have read and examined this application and I am author'zed and Blanket Permit Agreement No. and know the same to be true anc correct, to apply for and obtain this permit. , Signature:11 +1_ Organization: 14 q r` Print Name: Uji cd . it_ rC/` ; Phone No.: C Z Z te Address: y) tAMI S�� City /State /Zip kyf{— g670 DESCRIPTION AMOUNT RCPT # DATE Building Permit Fee 14 q r` Jop7Q� &-2.2.-10 Plan Check Fee f L O. 09 f Building Surcharge 4 6 TOTAL SIS 34 (0-22 -lf, CITY CS rUKWILA t Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Tenant Improvement Application PLAN REVIEW 1)401 NUMBER: 8 -0218 APPLICATION MUST BE FILLED OUT COMPLETELY Blanket Permit q7-_00-z_ _ g P ,. Agreement No.: / FEES for staff use onl Will there be ANY structural work? (7 No 0 Yes If "yes ", describe: See reverse side of application for specific plan submittal requirements and information. Date application accepted: 6-Z2 - Date application expires: /Z -ZZ- IS GENERAL INFORMATION 1 This tenant improvement application may be submitted for non - structural interior construction which Is authorized under an existing approved blanket permit agreement. It is the responsibility of the applicant to be aware and comply with all the terms and conditions as set forth in the agreement. The work is limited to that shown on the plans as submitted with this application, and such work is limited to non- structural interior construction only. The following work is not covered under the blanket permit process and separate approvals, permits and inspections are obtained through the applicable agencies. ELECTRICAL - Department of Labor and Industries (248 -6630) PLUMBING /GAS PIPING - King County Health Departm t2te !22 r f. FIRE PROTECTION - City of Tukwila Fire Department (5V-4400 +'� `• MECHANICAL - City of Tukwila Permit Center (431 -3670) RACK STORAGE - City of Tukwila Permit Center (431 -3670) BUILDING PERMIT APPLICATION Application Submittal - Application and plans must be complete in order to be accepted for plan review. Make sure to fill out the application completely and follow the plans submittal checklist which follows. Handouts are available at the Permit Center which provide more in -depth detail on preparing the submittal. Authorized Agent - The applicant must be an authorized agent as identified in the Blanket Permit. Fees - The permit fees are based on valuation of construction as declared by the applicant on the application, and shall include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision by the Building Official to insure compliance with current fee schedules. To obtain a fee schedule, contact the Permit Center at 431 -3670. SUBMITTAL CHECKLIST I ❑ Completed Building Permit Application ❑ Attachment #1 - Architects Statement ❑ Three (3) sets of construction drawings, which include: ❑ Site Plan, showing: O Building location on property O Adjoining public rights -of -way O Parking layout O Location of tenant space or area of work within building O Overall dimensions of building O Overall dimensions of tenant space, or area or work O Name of each common wall tenant(s) and type of business or occupancy ❑ Floor plan of entire floor or tenant space that the work is taking place, showing: O Tenant space layout with use of each room labeled O All exit doors, corridors and egress patterns O All new walls, existing walls and proposed walls (provide construction key) O All other proposed construction ❑ Construction details O Construction key O Cross sections showing wall construction and method of attachment, floor and ceiling O Reflected ceiling plan (if applicable) ❑ Miscellaneous O 6" x 8" blank space provided on lower right hand corner of each page of plans (for use by the plan checker) O Title block on each sheet, identifying: • Project name • Company job number (if applicable) • Site address • Blanket permit agreement number • Architect, address and phone number O Each sheet of plans stamped by a Washington State licensed architect O Minimum sheet size 18" x 24" O Plans must be drawn to scale and clearly dimensioned Drawings shall be prints which are clearly readable (original pencil or highlighted drawings are not acceptable.) ❑ Permit Fees (plan check fee, building permit fee and state building surcharge) Project .i, ' 7P/'- :en: • Type of 'nsctio - .. - �.� Date ca : • - Special instructions: .: •r, Date wanted: 1 - A G 1 g CD p.m, Requester: Phone No.: � i• > ' t':3f".pt.-AYr,r; r z;- 'rt7vswj:1 zz,- F4r .f:: icrT ..., INSPECTION RECD ' ) Retain a copy with p .sit ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 J Approved per applicable codes. PERMIT NO. (206) 431 -3670 • Corrections required prior to approval. Inspector: I (/ Date: $42.0 REINSPECTION E REQ I� must Prior to inspection, fee pi p m be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project Type f ip ection: Addre : / 2�,� /� �' S I7/'li �v2r l�C Date called: 711, ecia( jnstrs: a _pk _ - tv .u?.Q CaQ,Q Gw Am 4o . .: Date wanted: 7 16/98 , 1& Request / • • WW(l -t-- .. . Phgn 0 ) q69 — V 7a ! � 'i ?''ti 1.`.x yy a N K ." . 7 oc4Pt'x"&'to5taw4t3 �. ifr,' ,i MN Approved per applicable codes. I Receipt No.: INSPECTION RECO T Retain a copy with p ..0 92 r 2, / PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670. COMMENTS: I Inspector: c A C Date: I / ��r FT $42,00 RE NSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Corrections required prior to approval. Date: Project _ 14771 Type of inspectiOn: Ad Jo, 194 w,s4r Date called: 0 0 0 /0 Special instructions: Date wanted: 7/12/91 • P.m. Requ . , , IAA ee_iefr Phone No.. 7 30 — RoS I7 Approved per applicable codes. • =w22 t :"..74*(""t -4‘4Vgb" 4 INSPECTION RECOrl Retain a copy with p&-hit INSPETIN NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I I Lea-oaig PERMIT NO. (206) 431-3670 Corrections required prior to approval. COMMENTS: I Receipt No.: Date: Date: • 1 $42.00 REINSPECTIO FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Projec NrICC�,ri ir� T y of in ect n s, ,,02, ' .. Addr : 5 /j uer p Date ca ed: .J Special instructions: Date wanted: p �� 9��t� a.m. p.m. • Requ ter; e. W f Phone 06 96 9 4/ ?- r �1;::. �� 'W1z�'Ai'y:'c'..x'n.'i't+l'+�' r�" �k'.^, �', L' r'' 2�, ��'? �! �!' ��► h' rC�". tl;: k;"�a.� xk}^"*�'T':�'i`�':i�c.� � :i'.':�� >a.�;;�% INSPECTION REC Retain a copy with p INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. jgrj Corrections required prior to approval. COMMENTS:. n'e-ePe 4 -- 14,4 I Inspector: Date: Dq B oar.? PERMIT NO. (206) 431 -3670 r $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. L Receipt No.: Date: Project: ( cn e �n act Type of inspection: " N�t J l,z Liji Address: ~� 545 rAnc)o \ IIC W. Date called: [o•39 Special instructions: Date wanted: (0 - 3v' ! � a. �p•m• J Requester: Phone No.: L)5 8 to L VOS b "'^ ..t F kp —r rl" Lbw'% ?a*rs.! ! ,:rWR,,.. , " F 1tik "4'1%�fi7"�' .t INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: I Inspector: I Receipt No.: INSPECTION REC Retain a copy with pi Date. PERMIT NO. (206) 431 -3670 Corrections required prior to approval. [- 1 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: S' + 5 (" Type of inspe r `t t f i 13G Ad5sej Ali i zo f lc Ote called: (0 ar9...., Special instructions: Date wanted: art' a.m. -- ` � o�, Phollne�'N�, (. qv,' 1-7), pproved per applicable codes. INSPECTION REC Retain a copy with p INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. pi $42.00 REINSPECTION ! E REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [Receipt No.: Date: City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Project Name At e &/V I kA"" Address -SL/ t"1 PW Retain current inspection schedule X Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: �f. Authorized Signature FINALAPP.FRM aY7'; Yb It 1' ?�L y'� }J4 T`�'•J'` �ba t'••Y,e ' F "' ;�r .r '' f v Ya •• -$ +•w; ii � a 7 .P S7�" w'Sr•,` �3• iN+ �z/ S• 4ri' y�'" �* p���" 1 �'�.�^' v 'rl'`t'�N' S ��i� y l`.'� . TUKWILA 'FIRE DEPARTMENT FINAL APPROVAL FORM n Approved without correction notice Approved with correction notice issued Permit No. - b 9p- Cz ;/ U Suite # 7/) % e. T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57SS4404 • Fax (206) 5754439 4 c **A, * *.A. **-4 A.** ** II* :it tk 47 •;1/4—A—A-41—k k * •OrtIr * -IF is A.*** 4t4s tk 4c 4k CITY OF TUKWILA. WA TRANS:NTT • ****..gr ./.A•kticikleit.i...4•A*4—,Altlic*/141;4—kAlt*.Js*A****A***A*A—A*4 TRANSMIT 'Number : R970070-4 Amount: ',":%75.34 06/22/98. ; • • Payment Method: CI4ECK Notation: LOWI ENTERPRISES Ini Permit ,••No. D96-021/.3 Type: DEVPER14 DEVELOPMENT P,ERMt T • Parcel No 262304-9075 • • ite Address: 545 ANDOVER PK W , Location: BUII.DING #1. FL90Rt 170k.a.1 ‘z1 37., 34 .• This Payment 375 .,34 ota1 LL Pmts: • 375.34: c1s Dal ance: o• 44,N * * * * *.* '44,1).A * i41.,14A. * * * * 'A161744* •A is * * tl Account Code Descri at ion Amokint • 000/322.100 BUILDING — NONRES 224.75 000 /345.830 PLAN CHECK - NONRES 146.09 • 000/3E16.904 STATE BUILDING SURCHARGE 4.50 3.109 06/23 9717 TOTAL. 375.34 • Is any part of the work proposed under this application include structural work of affect structural components of the building? 0 Yes Or No If yes, has the structural work been authorized by the Tukwila Building Official to be included in this application? 0 Yes 0 No Does the proposed work comply with the requirements of Chapter 10 of the Uniform Building Code (1994 Edition)? (' Yes 0 No If no, please explain: Will any special inspections be required per Chapter 17 of the Uniform Building Code (1994 Edition)? 0 Yes Who If yes, list specific inspections: As a result of this proposal, does the parking meet the requirements of the Tukwila Zoning Code parking requirements? er Yes 0 No If no, please explain deficiency: Architect/Engineer Stamp: Architect/Engineer Signature: k\i Print Name: lb H • 5wA I 2364 A :,. vc STATE OE WASHINGTON ED G ii CT Firm Name: NW Business Phone: 'l (p • 223 • 50 33 Street Address: III 50 • JJ0 •"(. City /State/Zip: ' A T1( LA- • 41801 PLAN REVIEW NO.: • O24 PROJECT NAME/ TENANT: GOKICAKITRA JOB NO Y BLANKET PERMIT all. eta 5 P AGREEMENT NO.: SITE ADDRESS: 545 pAP$ W , Q Y OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Agreement Tenant Improvement Application Attachment 1 - Architects Statement App b octi: "X" REQUIRED INSPECTIONS DATE APPROVED INSPECT INITIALS PLANS DATE DATE(S) CORRECTION NOTICE ISSUED y 1. Framing 2. Insulation 3. Suspended Ceiling 4. Wallboard Fastening DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. CITY gr TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 ( Blanket Permit Agreement Tenant Improvement Temporary Inspection Card Plan Review No.: p/$. ova Blanket Permit Agreement No.: q-- Date Issued: 10, -ZZ,S Project Name /Job No.: Site Address: A-aptikew CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (431 -3670) (Have Plan Review number, Blanket Permit Agreement number, project name and site address ready) CONTRACTOR /APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. INSPECTIONS 1. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION - After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 25 and Table 25G). 5. PLAN CHECK INSPECTION - Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work may not proceed until the City Inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. • Construction will not proceed past required inspections. • The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. • Construction may not deviate from that shown on the plans as submitted at time of application. • All corrections shall be made within three (3) days of notification by Building Inspector. • No more than 30 days shall elapse between the last required inspection and the "Building Final." • Unauthorized occupancy and /or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. • The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. • The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: Electrical Department of Labor and Industries (248 -6630) Plumbing /Gas Piping King County Health Department (296 -4722) Fire Protection City of Tukwila Fire Department (575 -4404) Mechanical City of Tukwila Permit Center (431 -3670) Rack Storage City of Tukwila Permit Center (431 -3670) THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. DEPARTMENTS: 13 !r Nik z IferOUTI DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Incomplete ❑ Comments: TUES /THURS ROUTING: DATE: 6 -22 -98 ACTIVITY NUMBER: D98 -0218 PROJECT NAME: CONCENTRA XX Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision After Permit Is Issued SIZ 011 Icing Division Fire Prevention, Plann g Division Ppbsc Vi ❑ Structural L_1 Permit oordinator Please Route ❑ No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) LIP DUE DATE: 6 - 23 - 98 Not Applicable ❑ REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 7 - 21 - 98 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) 0 REVIEWERS INITIALS: DATE: \PR•ROUTE.DOC 6/98 City of Tukwila Fire Department Fire Department Review Control #D98 -0218 (512) June 30, 1998 Re: Concentra - 545 Andover Park West, Suite #109 Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1 Maintain fire extinguisher coverage throughout. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1- 1212.8) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) John W. Rants, Mayor Thomas P. Keefe, Fire Chief 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Plane: (206) 575.4404 • Fax (206) 5754439 C City of Tukwila Fire Department Page number 2 Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Local U.L. central station supervision is required. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Preventi Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax, (206) 575.4439 • 98036-5973 • 5 Abbreviations Angl Angle woo obe ipprox v Architectural �r° A Belding 91ky Blocking Tim Beam 9/S Budding Slondard 9sml Basement Cab 1abine1 cr, e,rNlnuon Clem or 1emence linen ne Dos Closet of CCP Corm, Chong eProposal Column Concrete Co Construction cant continuous Contr Contractor Cape Coordinate Carpet CT Ceramic Tile Del Detail Dia Diameter Dim 00 n o Dow, m Door Doug Drawing Rost To Each EL Elevation (Height) Elea Electric Pm Deviation (dew) Elevator En Enamel Eq Equal Exist Ex,sMg TF Factory finish fn `.nosh Flr low Fluor Fluarezcenl Plc Fumi n d by owner In /Ho by Coniraclor Foal /Feet FTC furnished by Tenant Installed by s r Turn Furnish /fumi0hingmings Go Gouge Golly Govan zed G Gass /G Ring G Cwsu We Board 1 cw w Care woad Hd Hard H Hardware antal Hollow HI Height Me of HVAC Healing, Ventilating, Air Conditioning Inch con andescnl include nso Insulation nstl Installation Junction eon Joint Kilden mina!" F Lineal Feral I9 Lighting at Material ech Mechanical tl Medium NEZ Mezzanine Manufacturer sc Miscellaneous Itl ounted II Mounted H North /A Not Applicable NIC Not in Contract NO Number ) Nom Non Comb Non Combustible NTS Not to Scale Oc On Center Opng Opening Opp Opposite Ong Orignal Perm Permanent Pl Perpendicular Plat P -Lam Plastic Laminate Plwtl Plywood Pol Pesned PR Pair Prop Properly PI Paint Rad RD ResNNnt Base f, Refrigerator Reid Reinforcing Req'd Req"i Rev Revision/Reverse Rm Room RO Rough Opening Rub Rubber South Schad schedule SCW 5ol0 Core Wood Seal Sealant Sect Section Sht Sheet Sim 5imlar SM Sheet Metal 5q Square Sld Sl ro da SU Steel ed Slg 500 Storage 0 Now Suspended Td Telephone Temp Tempered Rol mo Thermostat Typ Typical Mar Varies Vol 16,1 Composition Oe Wen Veneer Vert Vertim Vim Yny( WM Covering 05 west/Watt/Width Mth 0 010 O At Wall mn v ing cod woad U.N.0 Unless Noted Otherwise Door Schedule n0013 ,yOOR DOOR DOOR SOMBER SIN (W % Hr) T.. _ TYPE .NCWRE MATT RINISH•MAT'O FINISH REIAA1145 100 !'% MATCH EXIST H 3/4' 1 C FIR -I SONO ST -1 I WOOD . ST -1 RATED DOOR /RELITE /FRAME_ 101 3 MATCH EXIST. HI i 13/4 A 1 HW 2 SCROD ST -1 !WOOD ST -I l 102 3'X MATCH EXIST HT I 3 /a" B Hw 2 SCWO /GLASS 1ST - !WOOD ST-1 03 3'X MATCH CXIST. HT. 13/ 4" A HW 2 SCROD !ST-I WOOD 1 I ST -I .._.___- ..- ._...._____. K r 4 Sx MATCH EXIST. HT_ 1_3/4" B Hw 2 ' SCWD /GLASS 1ST -1 .WOOD 1sT -1 105 3x MATCH EXIST. HT. I -3/4' 1 B HW -2 SCWD /GLASS ST-1 WOOD ',ST -1 10 3'% MATCH EXIST HT I + -3/4' I A HW -3 :SCROD/GLASS T -1 WOOD ST - ST-1 WOOD '. ST-I I08 3'X MATCH EXIST. HT. 1 r -3/4" A HW -2 SCWP /CLASS 5T -I ..10000 ST -I Hardware No. Description W -3 Hardware General Notes: General Notes T Refer to basic building specifications requirements and standards Ix existing shell and core construction. 2. Ed the purposes of this work the following definitions oPPIY Owner'. Lowe E nterprises Ns,hwesl, Inc. Contractor: Manager Ran Creene Architect: T2 Arcmte: NeBJ 3. All work shall conform to applicable current Federal, Stole and Local Codes. the Contractor is to provide for all required notification of and coordination with City and State agencies. and provide reimPed permits for individual trade contractor. All tests and inspections associated with obtaining approvals to proceed with and complete the work shall be paid for by the Contract 4. The 'intent of the Contract Documents „ to include all labor and materials, equipment and transportation necessary 0r reasonably inferable as being necessary for the execution of the work. By submitting a proposal, the Contractor represents that 110100gh examination of the site and all existing conditions and limitations have been made and that the Contract Documents have been examined in complete detail, and Mal it is determined beyond doubt That the drawings, specifications and existing conditions are sufficient, adequate and satisfactory for adn0lments at no added expense to the owner. Where 00th moor construction of the work. Where minor adjustments to the work sort' for the purposes of fabrication and installation are f of res0ulians of l o between he within We intent of the Contract Documents, ms, the Contractor shall make such adjustments affect functional or aesthetic design of the work, they shall be submitted to the Owner in writing for renew and approval. 5. The Contract, shall coordinate all 000001ians with the Owner, including area for work, materials storage, access to and from the work. special conditions or noisy work, timing of work. interruption of mechanical and 0ectrical services and relocation of existing equipment. cosewo3, fixtures, fittings, lc. Noisy or disruptive work shall be scheduled at least one (1) week in adwnce of the time work is to commence. 6. All work shall be performed in accordance with the highest standard of workmanship in general and with such standards as are specified. Symbols IOTA ^ Door Na. Elevation Key Section Key Detail Key 1 101 ROOM NO. Revision Key 000R FRAME er " L tens <yle f'3ssape Se - Pr B L It hinges silencers, , � p , pet o floor stop ss required _ xeveisi yl Stgi ale Locf set _ i Hr 0 '5 butt hinges, le .errs. .0311 bumper or foot st as efix e1. Project Contacts: Amy Sparks Project Manger NBBJ III South Jackson Street Seattle, We 98104 Tone: (200)621 -2246 0001 (206)621 -2301 D98 -o218 d dog Stand •d Woe ono finish.) Fin. Maicn Existing Match Existing F(LS: 5 O l(RS A, F D AL L ! i'1 `TAR ink 15 TO BE REPLACED AS REQ'D To FEET ADA AND BIFL. E ACCESSiBiLiTY : EQU''0 'dilif!TS. Ccntractar shall adhere to all building standards. Any ranges to some shall be submitted to Architect in writing for approml. 8. Contractor shall submit samples of all finishes of such size and nun0Ser that they represent a reasonable distribution of color mnges and pattern prior to installation for Owner's 005100al. 000lractor shall provide shop drawings and product data To Owner's approval on all special items requiring custom fabrication. 9. Final cleaning at substantial completion shall include cleaning of all fished woad and glass surfaces: dusting of all horizontal surfaces vacuuming of all carpeted areas and removal of any spats, stains, sPdis etc., any surface incurred during the conslruclim period. 1a Condition and use shall be the respon0,5 ity of the GC. Job site shall be maintained in o dean and orderly fashion. Debris and trash for all trades and contractors under GC control and for those under direct contract with owner shall be removed daily. GC shall coordinate deliveries, inspections, site Mslls far all trades and contractors as required. 11. Contractor is to verify all dimensions and conditions on site and notify Owner in writing of any dbvepondes. Contractor is not to scale off drow',ngs. 12. Contractor shell provide 18-gouge sheet metal backing in partitions for all wall- mounted fixtures and devices unless indicated otherwise an the drawings. 13. All flows should be level and not vary more than 1/4' in 10' -0 The Contractor shall be responsible for correcting any conditions Mat do not meet this standard. IN Floor finish transitions shall occur under doors, unless shown or noted otherwise. 15. All materials indicated to match existing shall ON so with respect to size, shape, color, texture, pattern, quality and method of 10010101100 insofar os proclicable and shall be approved by the Owner before use. N. RI fireproofing disturbed during demo :ition or construction shall be replaced to match original fire protection levels. Ric Anderson Ace President Lowe Enterprises Northwest, Inc. One Union Square 600 University Street, Suite 282D Seattle, WA 98101 Phan, (206)623 -0200 Fax: (206)623 -0800 Ron M. Greene Chief Engineer Lowe Enterprises Northwest, Inc. Phone: (206)515 -2120 For (200)555 -1198 iI oar Types ° TYPICAL OFFICE SCW DOOR - MATCH EXIST. WOOD DOOR HT. 8' -3" - MATCH EXIST. DETAILS U.N.O. Door (Ty a i l III II 6 TYP. 1 -0 DOOR WIDTH DOOR WIDTH IA. Protect 501000nd, whether passersby. accuponts of existing building or visitors to the site Iran harm and i05ry. Carefully muintry Ind protect monuments. bench marks and Their eHrence paint from being destroyed or disturbed; replace as needed. 18. Existing work damaged as a result of work done under this Contract shall be repaired to original condition and finished to match adjacent 0nishes, subject to Owner's 000,04 Cl no additional cost to Owner. All replacement materials required to match existing materials shall 00 se with respect to type. po len, texturr., size, shape, color and method of installation insofar as practicable, and shall Me approved by Inc Architect and Owner prior to installation. Existing maleri0s 0150 ore to be removed may be used for the patching, but only with express approval of the Architect and Owner. 19. All existing mechanical and electrical equipment and services disrupted or removed during construction shall be restored and replaced unless noted otherwise. (Mere existing plumbing fixtures are removed, cap the supply vent and drains above the ceiling and below the floor. and patch openings. Remove fittings from walls and patch openings to accommodate the new required Orion. 20. Installation of mechanical, electrical and structural 050101ns wll require opening of some existing walls, ceilings or loin cavities. The Contractor she be respansble for the repair of these openings to match existing, except where noted otherwise. Fill all hales and voids in floors, walls and celmg which result from inslallotion of work, and removal of 'tug materials and equipment requnred by this Contract. Patched areas shall match the motedol0, fnfahes, and levels adjacent, orshol1 be put in Me proper 00003)0 to receive the O5sh indicated. 21_ Shop drawings shall be submitted to architect (4 copies) for review. Shop drawings enhance these specifications: approval of shop drawings shall not release contractor of respnsiNily for as specified. 22. Warranty shall be extended for all consimclion components and equipment and installations included in this work for o minimum of 1 year from dote of substantial completion. Scope of Work Z SCOPE OF WORK 1 01 , 30 O TYPICAL NON -RATED OFFICE DOOR W /RELITE. MATCH EXISTING DOOR HT. 8' -3 Standards .N.0.) MIN_ AT PUSH SIDE IF DOOR HAS / CLOSER NORTH TYP DOOR 100TH 23. Openings required for new work Mot penetrates existing structure shall be coordinated with Owner prior to commencing the work. Any opening over 2" in diameter shall be reviewed and approved by Owner. Through existing Boor structure or walls, or masonry walls, 011 round hales shall be core drilled with o d,00Ond drill and oil rectangular openings shall be cut with o diamond In no case shall any structural member be cut. Use carbide - lipped drills far gypsum wallboard partitions. Keep overcalling to a minimum. Maintain continuity and integrity of fie separation at all limes. Grout around conduits passing Through concrete walls and (hors and masonry wails. Make patches with neat, trimmed edges; match adj:cenl existing work. 24. Contractor shall provide hoar leveling as may be required 01 sliding doors, relines without base, cabinet work, and auto: locations requiring level substrate. Feather changes in devotion over sufficient area to limit 110000on slope to I/O ' per foal. 25. Motvlols. orl1cles; devices and products ore specified in Me documents by reference to the building standards, by listing acceptable manufacturers or products. by requiring compliance ith referenced standards, or by performance spedncations. For items specified by name, select any product named. For those specified by reference standards or by performance specifications select any product meeting or exceeding specified criteria. For approval Cl an item nal specified, submit required submittals, providing complete back -up informot,on for purposes of evaluation. mere building standard items are coned far, no substitute wiil be accepted. 26. Contractor shall provide for all work required to maintain compliance with Local Fire Code. Provide for all required shop drawings and approvals. All devices shall match existing systems. Contractor is responsible far providing Me alarm system audibility. 27. Mechanical and electrical fixtures, outlets, etc., when shown on the architectural drowfngs, are for location information only 100050nfcal and electrical to be dssfgne0 by others. All circuiting coordination to be by others. Location Map HI0 B C E A- 3 RELIT U ET O TRANDEFdy BLVD ;a i IN L E UPLAND DR. MI DLAN OR TRILA 0 OR VICINITY MAP N. F.S. IV 3/4 i t 7-0 I MAX 1. 0 TYPICAL SCW ENTRY DOOR - 20 mIN. RATED & LABELED. MATCH EXISTING DETAILS U.N.O. 28. Contractor is to provide drawings for Owners and Architect's approval showing locations of all HVAC thermostats. grilles and diffusers, fire and smoke detection devices including sprinklers smoke detectors, fire extinguishers and lire hose cabinets. 29. Any change in light fixture placement due to interference of mechanical or structural components must be approved by the 30. Carpel: Submit layout and seaming drawings showing carpet measurements. Include all plan features and !0000000 where cut- outs are required. Submit samples and complete manufacturer's recommendations and data including certification of cafe compliance. Install in accordance with manufacluis recommendations Provide toeless edge strips Loy with se ms parallel to long dimessi00 of room. Mainlofn direction of pattern and texture. Center under doors. Do not place seams in bone direction in doorways or sewn Clean carpet a'. compd. of work Provide protective covering. Provide all finish accessories. Furnish maintenance information. Return all surplus of practical dimension la owner. Provide for follow-up and warranty services. 31. Prior to start of constructan, CC shall coordinate scheduling of meeting with his project personnel, the bulding/Iandlor0 rep(s). Owner project manager, others for review of project scope, design intent construction quality expected, and final discussion of drawings/ details /questions. NORTH G'0 Legal Description 20121 r IN 'i,^ A WI T.3 1/ X 3/l ' ✓I) l /F. METAL ANIULE STOPS LL JJNID BOTH SIDES. 1 F S 5UII awes AREA nl AMf ONE PANEL NOT TO MELD :.296 SD. INCHES. - -- 3mL0mc STANDARD SIGN AGE 20- MINUTE RATED BUILDING 5 :ANEAR; DOOR PANEL 1,1 45 1NOTE RATED MR /REUSE FRAME 'SSEMB_i (ALL U1 LISTED AND APPROVED (OR 1 -HP PARSIMONI) EUILDIIOL STANDARD PUBLIC CORRIDOR BASE ON CORRIDOR SCE. Index TA -0 COVER SHEET TA -1 CONSTRUCTION PLAN, REFLECTED CEILING PLAN, POWER & COMMUNICATION PLAN, FINISH PLAN TA -2 DETAILS Special Notes 1. The Design Intent for this project is to match existing Building Standard details and Finishes. Field Verify, and notify Owner of discrepancies or conflicts between architecture' detoils and existing conditions prior to construction. eel g ro� na q eieaae.a nth<he a gPz o`r "�i'e`no° n : :s�`1 : "$f 105 V I %df�o� Sec 26, 12 RdE, a VN" ontl bem0 wars portaularly as mlc.w Address: understand that tho Plan Chock applov :lc ::r S' ;_at to errors end omissions and approval of O"N does not suils0W vlulaOon of any of :pled Code Or OfdYialaor Ilsoect M contractor's copy /6{ :. +-.. 11111110011dped. By 11 our � T 1 Date Permit No. Building Code: Construction: Fire Protection: Occupancy Type: PILE COPY Agency Notes 555 Andover Park West Tukwila, Washington 1994 UBC VN Sprinklered B Office SEPARATE PERMIT REQUIRED FOR: arMMECHANICAL C ELECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION NBBJ 111 South Jackson Street Seattle. Washington 48104 (2061 223 -5555 Fax 12061 621 -2300 O R36 -I TERED ' RE Ci ,,,,N LOWE ENTERPRISES NORTHWEST, INC. CONCENTRA Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 MI T Nor � ik 19 -002 -IVA I\b r Sheet (Amber Steel Ms COVER SHEET Scale De AKS Dee 5/17/98 Appoved By RECEIVED CTTY OF TURN /ILA r1 ti H PERMIT CENTE'I Prom SXC alerkw WBP Im NA. 40951 15 No. Name Remarks CPT -1 CARPET TO BE DETERMINED RB -1 BASE TO BE DETERMINED ACT -1 VCT TO BE DETERMINED PT -1 PAINT TO BE DETERMINED ACT - ACT 1 BUILDING STANDARD (EXISTING). PL - -1 LAMINATE TO BE DETERMINL'J Symbol Fixture Watts /Fix. Quantity Total Watts Existing ES/Std. 2x4 Fluorescent fixture. Daybrite Recessed, with 1 1/2" Poracube lens typ. 120 15 1.800 I I 1 ig 161 El/Std. Exit Lignt - - - -- - -- - Existing 2X4 ceiling grid w/ existing 2X4 ceiling file to remains Armstrong Second Look II ACT -1 N/A 101 W atts Allowed: Total Watts Prodded: 15.32 SO.FT. 1.2 WATTS /SO.FT. = 18.38 WATTS Scope of Work: 1,800 watts Note: I. See Detail 7 /TA -2 for Seismic Bracing at Ceiling Grid. Symbol Description Floor MU. EXISTING WALL TD REMAIN North Walls South EXISTING WALL TO BE DEMOLISHED West NEw BLDG STD PARTITION TO ACT, SEE DETAIL 12/TA -2 Remarks 1 ig NEW 5' -0' LOW HEIGHT PARTITION W /WOOD CAP, SEE DETAIL II /TA -2 .�,,._. ,, RB -1 EXISTING PT - -1 No. Hoorn Name Floor MU. Base MU. North Walls South East West Ceiling MU. Remarks 1 ig p en tTee pt -1 RB -1 PT -I PT - -1 PT -1 PT -1 ACT -1 o ALL TINISHCO TO MELT CLASS "A" PRE 101 LUUCU ecom _ - -I RA-1 PT -1 PT -1 PT - 1 PT -1 ACT -1 SPREAD RATING. 10? Oi`i:e I:pt. 1 RB - 1 PT - 1 PT - 1 PT - 1 PT - 1 ACT - 1 :03 Gflice Cpi -I RB -1 PT -i PT -1 PT- -1 PT - 1 ACT - 1 1U4 Office Apt -1 RD-1 P'T -1 PT -1 PT -1 PT -1 ACT -1 :0.0 Off , :e. Opt - 1 RB - 1 PT - 1 PT - 1 PT - 1 PT - 1 ACT - 1 I06 Office Opt- -1 RB -1 PT -1 PT -1 r'T -1 VT - 1 ACT- 1 07 Storage Cpt -1 RE-1 PT -1 PT -1 PT -1 PT -1 ACT -1 08 Conference Rm. Cpt -1 RB -1 PT - -1 PT -1 PT -1 PT -1 ACT -i 'ISDNL INOUR RATED VO CLG ENCLOSURE OMMIIMM ® M e! 11 1 LUNCH KM FLOOR PLAN IA .. 1 I/h = H-1) 1/8 = I - REMOVE EMSRNC CASEWORK rlaINNOI L_Ls2 Ii of F', CE SCOPE OF WORK REFLECTED CEILING PLAN i 44 FEE NORTH 7 Construction Notes: 1. WHERE EXISTING IS RETAINED, CLEAN, PArCH, REPAIR AND FINISH TO BE EQUAL TO NEW CONSTRICTION 2. VERIFY EXISTING CONDITIONS PRIOR TO DEMDUTON AND INFORM ARCHITECT OF ANY ISSUES. DISCREPANCIES. OR CONFLICTS PRIOR TO CONSTRUCTION. 3. ALL FIREPROOFING DISTURBED DURING DEMOLITION SHALL BE REPLACED TO MATCH ORIGINAL FRE PROTECTION LEVELS. MAINTAIN CONTINUITY AND INTEGRITY OF FIRE SEPARATION AT ALL TIMES. 4. PATCH AND REPAIR PARTITIONS AS REQUIRED DUE TO DEMOLITION WORK IN ORDER TO ACCEPT NEW WALL FINISH. 5. PATCH AND REPAIR FLOORS AS REQUIRED DUE TO DEMOLITION WORK. SKIM AND PREP FLOORS AS RNA TO ACCEPT NEW FLOOR FINISH. 6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATION. DETAIL DIMENSIONS TAKE PRECENDCNCE OVER PLAN DIMENSIONS. 7. ALL DIMENSIONS ARE TO FINISHED FACE OF PARTITION. COLUMN. ETC. UNLESS NOTED OTHERWISE. ALL DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF FINISH MATERIALS. 8. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE FINISHED EDGE OF JAMB LINO. 9. REUSE DOORS, REMITS AND HARDWARE FROM EXISTING INVENTORY WHENEVER POSSIBLE. COORDINATE AVAILABLE INVENTORY AND ACCESSIBILTY WITH OWNER. rap VERIFY DIMENSIONS AND CONDITION OF UNITS TO BE REUSED. TOUCH UP STAINED FINISH AS REOO FOR NEW APPEARANCE. NOTIFY OWNER OF DISCREPANCIES PRIOR TO CONSTRUCTION. W. EXISTING HVAC SYSTEM S TO BE MODIFIED AS REQUIRED DUE TO NEW CONSTRUCTION. ALL WORK TO CONFORM TO STANDARDS AND DIRECTIVES AS PROVDED BY OWNER. GENERAL CONTRACTOR TO COORDINATE SCHEDULE OF HVAC WORK REO'D WANNER. COORDINATE NEW THERMOSTAT LOCATIONS W /TENANT AND ARCHITECT PRIOR TO INSTALLATON. 11. ALL PENETRATIONS AT ONE HOUR RATED PARTITIONS SHALL BE SEALED TO HAVE THE SAME PROTECTION LEVEL AS PARTITION. PRUDE AND INSTALL ARE DAMPERS AT HVAC DUCT LOCATIONS. ONE -HOUR FIRE RESISTANCE RATING TO BE MAINTAINED AT ALL TIMES PER ALL APPLICABLE BUILDING CODES AND ORDINANCES. Q. ALL WOOD TO OE TREATED IN ACCORDANCE WITH LOCAL CODES. Q. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. Q. ALL EXISTNG AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL BE FULLY' PACKED AND SEALED IN ACCORDANCE WITH APPLICABLE BUILDING AND FIRE CODES. 15. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL SQUARE AND TRUE. 16. ANY DIMENSION RENSIONS /MODIFICATIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT'S PROJECT MANAGER FOR RENEW AND APPROVAL. REFLECTED CEILING LEGEND CONSTRUCTION PLAN LEGEND DcM-D2.18 Finish Schedule REFLECTED CEILING PLAN NOTES I. CLEARANCES FOR ALL RELATED PLENUM INSTALLATIONS. SHALL BE COORDINATED BY THE GC. 2. REMOVE ACOUSTICAL CEILING TILE THROUGHOUT CONSTRUCTION AREA AND SALVAGE FOR REUSE. REPLACE DAMAGED CEILING TILES WITH NEW TILES TO MATCH EXISTING. 3. CEILING PLANE SHALL BE LEVEL AND TRUE AND IN ALIGNMENT WITH ALL LIGHTING, SPRINKLER, HVAC AND OTHER ELEMENTS INCORPORATED IN ITS CONSTRUCTION. GRID SHALL BE CONTINUOUS THROUGHOUT THE DEMISED AREA. 4. PROVIDE ACCESS CUT -OUT IN GWB AND TRIM AS REO'D FOR ALL LIGHT SWITCHES. PATCH & REPAIR EXISTING GWB AS REQUIRED WHERE LIGHT SWITCHES ARE LOCATED. 5. VERIFY EXISTING LICHT FIXTURE LAYOUT PRIOR TO INSTALLATION. NOTIFY OWNER & ARCHITECT OF FIXTURE LOCATIONS THAT CONFLICT WITH MECHANICAL SYSTEMS, OTHER ELECTRICAL OR STRUCTURE ABOVE PRIOR TO CONSTRUCTION. 6. ALL SWITCHES TO BE LOCATED 5 48 A.F.F. TO CENTER OF SWITCH UNLESS NOTED OTHERWISE. MULTIPLE SWITCHES AT ONE LOCATION BE GANGED TOGETHER AND FINISHED W/ ONE COVERPLATE. LIGHT SWITCHES TO CONTROL FIXTURES WITHIN THE SAME ROOM U.N.O. 7. THE REFLECTED CEILING PLAN INDICATES LIGHT TYPES AND ASSOCIATED ITEMS. COORDINATE CIRCUITING, WIRE LAYOUT AND ADDITIONAL INFORMATION WITH ELECTRICIAN. 8. EXISTING ELECTRICAL LIGHTING FIXTURES TO BE RETAINED FOR REINSTALLATION. PROTECT STORED FIXTURES PROM DAMAGE DURING CONSTRUCTION. 9. CLEAN FIXTURE LENSES, REPLACE DAMAGED LENSES, RELAAP FIXTURES THROUGHOUT AS REQUIRED. ID. FINISH OF ALL NEW SWITCHPLATES TO MATCH EXISTING. II. ALL LIFE SAFETY DEVICES AND EMERGENCY LIGHT FIXTURE LOCATIONS TO COMPLY W/ ALL APPLICABLE CODES AND ORDINANCES. 12. ALL PENETRATIONS AT ONE-HOUR RATED CEILING SHALL BE SEALED TO HAVE THE SAME FIRE PROTECTION LEVEL AS PARTITION. PROVIOE AND INSTALL FIRE DAMPERS AT HVAC DUCT /DEVICE LOCATIONS. ONE -HOUR FIRE RESISTANCE RATING TO BE MAINTAINED AT ALL TIMES PER ALL APPLICABLE BUILDING CODES AND ORDINANCES. 13. PARTITIONS SHALL NOT PENETRATE THE CEILING PLANE EXCEPT WHERE ACOUSTICAL OR FIRE PROTECTION CONSIDERATIONS ARE CALLED FOR (SEE CONSTRUCTION PLANS). ACOUSTICAL CONTRACTOR SHALL COORDINATE WORK WITH CARPENTRY TRADES TO PROVIDE FOR A NEAT, LEVEL USUAL LINE AT THE INTERSECTION OF CEILING AND PARTITIONS. 14. VENTILATION FOR THE ENTIRE TENANT SPACE SHALL MEET THE STANDARDS SET BY THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE FOR THE SPECIFIC OCCUPANCY OF EACH ROOM. 15. ACCESS SHALL BE PROVIDED BY GC AS REQUIRED FOR INSTALLATION AND MAINTENANCE OF MECHANICAL, ELECTRICAL AND OTHER ELEMENTS WITHIN THE CEILING PLENUM AND AS REQUIRED BY CODE. LOCATIONS FOR SPECIAL ACCESS DOORS, HATCHES. ETC. SHALL BE COORDINATED WITH OTHER TRADES AND APPROVED BY OWNER. AS BUILT REFERENCE PLANS SHALL BE PROVIDED. 16, INSPECTION, AS REQUIRED BY LOCAL AUTHORITIES SHALL BE COORDINATED BY THE GC PRIOR TO THE CLOSING OF THE CEILING. 17. SHOP DRAWINGS FOR ALL RELATED TRADES (PLUMBING, SPRINKLER. HVAC) SHALL BE SUBMITTED FOR REVIEW /APPROVAL PRIOR TO MANUFACTURING AND INSTALLATION. A COORDINATED SHOP DRAWING FOR ALL VISUAL CEILING ELEMENTS SHALL BE SUBMITTED. 18. MECHANICAL AND ELECTRICAL CONTRACTORS SHALL COORDINATE WORK WITH ARCHITECTURAL DRAWINGS. ARCHITECTURAL CEILING PLAN SHALL GOVERN WITH RESPECT TO LOCATIONS FOR CEILING PENETRATIONS AS AESTHETIC AND FUNCTIONAL CONSIDERATIONS DICTATE. MECHANICAL DOCUMENTS SHALL TAKE PRECEDENCE WITH RESPECT TO OVERALL SCOPE OF WORK. Materials Legend FYI k® Finish Notes: I. WHERE EXISTING IS RETAINED, CLEAN, PATCH, REPAIR. AND FINISH TO BE EQUAL TO NEW CONSTRUCTION. 2. PATCH AND REPAIR ALL PARTITIONS AS REQUIRED DUE TO DEMOLITION WORK IN ORDER TO ACCEPT NEW WALL FINISH. 3. PATCH AND REPAIR ALL FLOORS DUE TO DEMOLITION WORK. SKIM AND PREP FLOORS AS RESO TO ACCEPT NEW FLOOR FINISHES. 4. ALL PARTITIONS WITHIN THE LIMIT OF WORK, NEW AND EXISTING TL BE PAINTED PT -I (U.N.O.). 5. ALL FINISH MATERIALS TO MEET CLASS "A" FLAME SPREAD RATING. 6. CLOSED CASEWORK AND DRAWERS TO HAVE WHITE MELAMINE INTERIORS OPEN CASEWORK TO HAVE PLASTIC LAMINATE INTERIORS (SEE MATERIALS LEGEND, PL -I) DRAWER EDGES TO HAVE PVC EDGE TO MATCH ADJACENT LAMINATE COLOR. OPEN SHELVING TO MATCH PLASTIC LAMINATE. 7. PROOF RUBBER OR ONTL REDUCER STRIPS AT TRANSITIONS BETWEEN CARPET AND VCT. COLOR TO MATCH CARPET. PROVDE A RANGE OF COLORS TO CHOOSE FROM. Power & Communications Notes: I. ALL WALL MOUNTED OUTLETS SHALL BE S 18" A.F.F. UNLESS NOTED OTHERWISE. HEIGHTS SHALL BE DETERMINED FROM FINISHED FLOOR TO THE CENTERLINE OF COVERPLATE, INSTALLED VERTICALLY GROUNDING POLE AT TOP. 2. INDICATED DIMENSIONS ARE TO CENTER OF THE COVERPLATE: CLUSTERS OF OUTLETS ARE DIMENSIONED TO CENTER OF CLUSTER UNLESS NOTE OTHERWISE. OUTLETS SHOWN ADJACENT TO EACH OTHER SHOULD SHOULD BE PLACED WITH MINIMUM DIMENSION BETWEEN THEM, U.N.O. 3. CONTRACTOR TO COORDINATE ALL WORK RELATED TO EQUIPMENT WITH MANUFACTURERS RECOMMENDATIONS. SPECIFICATIONS, AND INSTRUCTIONS, INCLUDING SPECIAL RECEPTACLE CONFIGURATIONS FOR ALL COPIERS AND PRINTERS. 4. ALL NEW COVER PLATES TO MATCH EXISTING FINISH. 5. CONTRACTOR TO PROVIDE MUDSTRINGS AND PULLSTRINGS. ALL DATA AND PHONE LINES NOT INCLUDED IN CONTRACT. 6. POWER REQUIREMENTS FOR OPEN AREAS CONTAINING SYSTEMS FURNITURE AND WORKSTATIONS, TO BE SUPPLIED AND /OR VERIFIED BY TENANT'S FURNITURE VENDOR. POWER & COMMUNICATIONS LEGEND Writ Mounted Duplex Outlet Wall Mouplex 0n Dedicated unted D Circuit. Outlet Well Mounted 4 -Pk. Outlet Wall Mounted Combinoliorl Data/ Telephone Outlet Wall Mounted Telephone Outlet NBBJ 1U South Jackson Street Seattle, Washington 98104 (2061 223 -5555 Fox (206) 621 -2300 1 REGIST RED A, EHi ECT STATE 0E WASHIna rON LOWE ENTERPRISES NORTHWEST, INC. CONCENTRA Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 6/17/98 SXC PERMIT SET Herber Dare By Description of Ree000 Seel Title Sheet Nnber CONSTRUCTION /FINISH/ POWER /COMMUNICATIONS REFLECTED CEILING PLANS DeNigrAd AKS Drams SXC Dole 6/17/98 Checked WBP AWao.ed By lob Nedw 40951.15 REC e 1 CI I'f OF IU,4WIIACT'OFTUKWILA TI :IAIJVL.J '.lid U 012,0 JUL A U 15 PERMRCENTER L 1 MIN ACT CEILING ICE LINE OF CEIL ,FD METAL EDGE IRO: -- BLOCK SPACER ABOVE & BELOW GRID AT PONT OF CONNECTION (FUN GRID THROUGH) 2 3/4 ACOUSTICAL BAITS — AT SOUND PARTITIONS ONLY EXIST SIRED FLOOR ATTACH CROSS BRACING TO 'LOOK DECK t9/ RAMSET FASTENERS ?YP RESTORE ALL DAMAGED FIRE- PROOFING TO ORIG. FINE RATNG -- CROSS BRACING AT 7' -9" 0.C., 2 I/O ° v 25 GA STEEL STUDS ATTACH NO (3) b6 SET XITL SCREWS ATTACH CROSS BRACING THE SPACER TO RUNNER W /g6 SHT MTL SCREW 5/8" GWB EACH SIDE OF 2 1/0" 25 GA. METAL. STUDS B 24" D.C. CONTINUOUS SIC TRACK ANOIOREE TO FLOOR M 2' -0' O.C. BASE PER FINISH SCHEDULE - -- FINISH FLOOR PER FINISH SCHEDULE ,_I...........'a' _- EXISTING CONCRETE FLOOR SLAB 0 INTERIOR PARTITION (W /BRACING) TO CEILING 10 PARTITION TO MULLION 'GALE 3 = 1 -C" (AT UNSUPPORTED WALLS O SCALE: 3° = I . -0 " GREATER THAN 7' -9" LONG) 13 WORK SURFACE \ , PLASTIC LAMINATE ON 3/4 MILE COUNTER & CENTER SUPPORT. I/4 PARTITION TO WINDOW CENTER DIVIDER O RELITE SILL SCALE. 3' - 1 •0" I l llf :1111 I 11 LOW PARTITION SALE: Not to Scele - EDGE OF INTERIOR SILL BELOW VERIFY Dqg-02_18 EXTERIOR WINDOW SYSTEM CASED BEAD TYPCAL 25 GA MTI STU_ PARTITION (ATTACH GWB TO INBOARD STUD ONLY) 1 SUP .DINT 25 GA. MIL STUD W /CONT. FOAM TAPE (DO NOT ATTACH CWB SLIP JOYT) CASED EEAC BACKER POD & CONTINUOUS CAULK 'D (TYP. EA. SIDE) TYPICAL 25 GA MR. STUD PARTITION (ATTACH GWB TO INBOARD STUD ONLY) I" SUP .:DINT EDGE OF INTERIOR SILL BELOW 25 GA. MIL STUD W /CONT. FOAM TAPE (DO NOT ATTACH GWB) SLIP JOINT) CONTINUOUS GASKET, SELF ADHESIVE EACH SIDE SILICONE SEALANT EACH OE EXT ALUM WOW SYS BY SHELL /CORE STAIN GRADE WOOD CAP ▪ t - G .�.��.�. C ,— STAIN GRADE WOOD TRIM F.T. WD. BLOCKING ATTACH TO TOP CAP FILL FASTENER AND SAND SMOOTH - PREPARE FOR WALL COVERING CONTINUOUS RUNNER 5/8 GYP. BD. BOTH SIDES OVER 2 I /2' METAL STUDS RESILIENT BASE END WALL CONDITION CORRIDOR ` 3 / 4 " _ OFFCE SIDE 2 1/7 STIDS CORRIDOR N OTE N0. 1 _ _ __ _ _ -- 1/4" WIRE GLASS WITH GLAZING GASKET ALL AROUND BOTH SIDES V RELITE @ DOOR JAMB IN 1 -HOUR WALL (2) RELITE JAMB SCALE 3" = 1' -0" SCALE: HALE SIZE NO NO. 2 4 TURNS MIN. WINN I -I/2 TIP. 45 ° MAX. IIP. kurrall FASTEN RUNNERS TO PERIMETER WALL ANGLE AT (2) ADJACENT 5ITSS NOTES: NOTE NO 1 45 "MAX TAP CROSS 'T' 2° MAX TIP VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE 1. LATERAL BRACING CLUSTER: (4) 12 CA. GALV SOFT- ANNEALED MU) STEEL WARES SECURED TO MAIN RUNNER BATHIN 2 OF CROSS ' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12' -0 O.C. X 8' -0' O.C. AND 4' 4' MAX. FROM EACH WALL. ;SAES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. SUSPENSION WIRE: 12 GA. CALM. SOFT- ANNEALED MILD STEEL WIRE ENCASED IN 1/2" DIAM. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4' -0 O.C. MAX. EACH WAY 0 7 SEISMIC BRACING @ CEILING GRID @ ACT NO SCALE MAIN RUNNER 1/2 x 3/4 (LLH) METAL ANGLE STOP ALL AROUND 80TH SIDES - COVER WITH WOOD TRIM STOP AS SHOWY 1/8" X 1/8 REVEAL (TAP.) NON -COMB WOOD BLOCKING 5 /B' TAPE -X GAB EACH SIDE OF 2 1/2 METAL STUDS W 24 O.C. WOOD BASE RESIDENT BASE - - -- CARPET (AS SCHEDULED) I/4" WIRE GLASS WITH GLAZING GASKET ALL AROUND BOTH SIDES I/2 X 3/4 (LLV) METAL ANGLE STOP ALL AROUND BOTH SIDES - COVER WITH WOOD TRIM STOP AS SHOWN 20- MINUTE RATED DOOR LEAF 4o- MINUTE RATED 20 MIN. DOOR AND RELITE FRAME ASSEMBLY - U.L. LISTED AND APPROVED AT I -HOUR PARTITIONS I/8" X 1/8 REVEAL (TIP.) ANAL COMPOSITION TILE (ACT) VINYL REDUCER STRIP ( CTA -XX -C OR EQUAL) COLOR TO MATCH CARPET CARPET CONCRETE SLAB NOTE N0. I RUNNER ENOS AT OPPOSITE WALLS TO FLOAT FREE ON PERIMETER ANGLE DOOR PER SCHEDULE B.S. DOOR /REL IT FRAME - MATCH EXIST DETAILS & FINISH 15/8" NEWEL STOP W/ FOAM ... TAPE BETWEEN STOP & GLASS EA SIDE. ATTACH W/ CSNK. FINISH NAILS. TEMPERED GLASS RELITE - - (REFER TO 000R SCHEDULE) HARDWOOD DOOR STOP. ATTACH W/ CSNK_ FINISH NAILS . FILL HOLES. FINISH TO MATCH EXISTING. DOOR /RELITE JAMB 1t2 11/2" I/2 XISTING FLOOR DE 11/2 3 3/44° (3 DOOR HEAD SCALD HALF SIZE CORRIDOR 0 VINYL COMP. TILE /CARPET TRANSITION O TYPICAL DOOR JAMB SCALE: FULL SIZE NON COMB BLOCKING 25 GA SIC STUDS R. BLK'G 5/8 GWB EA SIDE ACOUSTICAL CEILING TILE ACOUSTICAL CEILING GRID > FOR PARTITION TYPE AND HEIGHT SEE / CONSTRUCTION PLAN & REFERENCE DETAIL 1 /TA -8 OR 2 /TA -8 SHIM AS REQUIRED B.S. DOOR FRAME. ATTACH TO BLOCKING W/ COUNTERSUNK FASTENERS. FILL HOLES. FINISH PER SCHEDULE. B.S. HWD CASING - MATCH EXIST. CONDITIONS FOR REVEAL, FINISH, AND DETAILS DOOR PER SCHEDULE HOC STOP. ATTACH 0/ COUNTERSUNK FINISH NAILS. FILL HOLES. FINISH TO MATCH EXISTING FINISHES BUILDING STANDARD DOOR AND FRAME (0- MIINUT RATED Al I -HOUR 5 /8 ONE EACH SIDE OF 2 I /2 METAL STUDS ®24 O.C. IUL 081..,1 3 NBBJ Ill South Jackson Sneer Seattle. Washington 93104 1206) 223 -5555 FOR (206) 621 -2300 LOWE ENTERPRISES NORTHWEST, INC. CONCENTRA Southcenter Corporate Square 545 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 BUILDING 1 FLOOR 1 RIA►•ll'tT p 1IT No.:* q?- 002 -br^ 1 6/17/98 SXC PERMIT SET N.rtbW Dale By DesWRpr n of Re TI DETAILS ANON Devgned AKS Drown SXC Dare 6/17/98 Checked WBP Approved BY Job nwber 40951.15 Sheol NM,nber OP OF TUKWILA TA-2 A.PPRT14ED RECEIVED CITY OF TUKWILA 11�h PERMIT CENTER