Loading...
HomeMy WebLinkAboutPermit D98-0225 - SOUTHCENTER MALL - RAINFOREST CAFE - PARTITIONS REMOVALD98 -0225 290. Southcenter Mall Rainforest Cafe City of Tukwila WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9023 Address: 290 SOUTHCENTER MALL Suite No: Location: Category: ACOM Type: DEVPERM Zoning: Const Type: II -N Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: Contractor License No: PCLCOSI099NW Permit Center Authorized Signature:_ DEVELOPMENT PERMIT .0 South: .0 East: .0 West: .0 Sewer: TUKWILA Slopes: N Streams: Permit No: Status: Issued: Expires: Date: (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 D98 -0225 ISSUED 09/04/1998 03/03/1999 Occupancy: STORE UBC: 1994 Fire Protection: SPRINKLERED OCCUPANT RAINFOREST CAFE 633 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT PHYLLIS ROOT 275 118 AV SE #105, BELLEVUE WA CONTRACTOR P C L CONSTRUCTION SRVC INC Phone: 425- 454 -8020 PO BOX 52868, BELLEVUE WA 98015 *************************************** k********* k*** k * *** ** * * * * * * * * * * * * * * *k * *k ***** Permit Description: INTERIOR TENANT IMPROVMENTS - REMOVAL OF PARTITION WALLS BETWEEN FIVE TENANT•SPACES (278 SOUTHCENTER MALL - WOMENS WORLD, 284 SOUTHCENTER MALL - MARIPOSA, 290 SOUTHCENTER MALL - GENE JUAREZ, 294 SOUTHCENTER MALL - AS SEEN ON TV AND 296 SOUTHCENTER MALL - HIGH AND MIGHTY) TO CREATE. ONE NEW TENANT SPACE FOR THE RAINFOREST CAFE. *********************** k***************************** *k * * * * * * * * * * * * * ** * * * * * * * * * * * * ** Construction Valuation: $ 70,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ , 1,159.09 ********* * * * * * * * *k*** ** ** * * * * * * * * * * * *k ** ************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date : 9-4-95 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the prov ion of an other state or local laws regulating construction or the perfor'.nce of,/ I am authorized to sign for and obtain this development 4.(20e This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUICWILA Address 290 SOUTHCENTEP MALL to Tenant Type.' EIEVPERM Parcel. #: :262304 -90.23 ** **•k* *** ******: * * *** Status: 'ISSUED Appl.iod:. 06/29/1998 Issued: 09/04/1998 * *' *•k•k *•k* * * *•k•k k•k•k *•k * *•k k *•k•k * *•k•kk•k k k•k *•k * k k* *•k•k *N•k•1e k k•k k * ** Permit Oond i to co 1 Na changes wi 11 be made to the plans unless approved bv' the .. `Architect or Engin;eer' and th.e Tukwila Buiidi:ng Division.' All p ermits ectio.r , ;recordst arid a':ppiroved plans Shall 'available at the i`ob°s.i,:te ° ior to the st "art;,o.f.anv con- struction.• These ^svcume.nts to. be mainta•lneiikand avai.l- able until fit {a'l i'nspe t,i ar pro `Al1 constructzan to,be done:. "iris info "rrmancej with `= e Droved {. 1 h 4 3 { ?.f !� flans and Jrheoc i i r eme nts of the 11,1 ov m Bu i l d;i riq ti0 Editier), "aA%ainendetki Un itor{m'Me harii'xca3l :code `(i 97r Ed:i.,t'ion): and Washington Stacte Ener gv co (1997 Etiitiotik 4, 4 : , '� Val d i the of P e'i;m i t . The i ss s a pel- m it,: o R.,,tit va }tis plans= sDeclfi;Caitiens anklYfOOmputati,ons sha11 not becon tr ued/to be . " permit f=ur, ut an approval of anv viola ici of anv{ of the provisions of 'the building ro or .of airib 0t he"rY o rdinance 'of: the iurisdl : No uermit aresu+tri "r?r�. to :g iveFauthoriti to violate or- cancel the provisions of ,i r f r `codef "be vali ci° 7 , • ;; 5 tFj • �, ? ,t �,, 'El 4: tr;ical a rmlts ,shall be' obt,a�ind' e throw h the Washington S tate D l i e on' of Lab�t,jand In'tiva "tr ies� and. :el wai��l wi l i be °'i nspected by a tha 'agencv (2',4 Projec e/Tenant: �� �7 Ca Pe tD°v/110 LEA ) 'J Value of Construction: , 1 , ia �, 00 0 Site Address: ,. State /Zip: rte, /0 U /1 eZifg, -. /f � Proposed use: etail Restaurant ❑ Multi- family ❑Warehouse ❑Hospital Church ❑ Manufacturing ❑ Motel/Hotel ❑ Office ❑ School/College/University ❑ Other Tax Parcel Number: .goo a3 Di/ 9cx0 Pro�ert� O er: X"Pi 1.1 Y�c� r-pa � o, )11 t'.. t'.. p Will there be rack storage? ❑yes ❑ no Phone: . �l 87/ q Q Str Address: �f/�S r,� c / / tid� h4 4 L ape ,, , " / �C�y,,St � //5 Fax #: Contractor: // t CoH rucfrc7*-7 Co,-LA ' •0S 4 7-2(c_ Phone: KZ S 5 'ygOZo Street Address: ,, State /Zip: 7'� 1 �h e .S. e• /os P %w 7& Fax #: n5 vs-v- 5-9a Architect / 4 c- t��P�t r r .P S/ �? �PrrJrC�PS �, Phone: 2/lo 2 7l Z'ar):" Street Address: / State /Zip: A5 C C 1h :1 V C %ae � .2 � e7 4/(/ Fax #: Engineer: Phone: ress: City State /Zip: Street Add Fax #: Contact P e // S �� Phone: g5 / Street Address: y City State /Zip: al75 /IS" /e 5- /d5 &/ ' 9,p0D " Fax ft: / Yz.s «ss/ Sr , Description of work to be done: Refry/0 a' ( I reo ern° - _ ` ..4. - f" n (_ e . A1 - JL e /cQ4 r✓ LEA ) 'J 1 Q I e 51 x SP CO , "' a C ps! I'-. C74, O 4-2 Existing use: ra .'etail ❑ Restaurant i ■ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ Sch /College /Univers' y ❑ Other Proposed use: etail Restaurant ❑ Multi- family ❑Warehouse ❑Hospital Church ❑ Manufacturing ❑ Motel/Hotel ❑ Office ❑ School/College/University ❑ Other Will there be a change of use? 4_Dyes ❑ no If yes, extent of change: (Attach additional sheet if necessary) F174 / / 1p S /4 .1 1 rQ K A Will there be rack storage? ❑yes ❑ no Existing fire protection features: sprinklers ❑ automatic fire alarm El none ❑ other (specify) Building Square Feet: existing fAteg of ; Construction: (sq. ft.) >(o� S/ c7 ' ..nrwoY.nSix ..,.. Will there be storage of flammable /combustible hazardous material in the building? ❑ yes Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TU "WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: El Land Altering 0 Cut ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): ❑ Miscellaneous CTPERMIT.DOC 1/29/97 APPLICANT REQUEST FOR PUBLIC WORKSSITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) Size(s): cubic yds. 0 Fill cubic yds. ❑ Sewer Main Extension ❑ Water Main Extension 0 Deduct Est. quantity: ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. • Date applicatioq acce e1 r Date yca; t/on lr qs Appllcaflon t ken (initials) AT7 - PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER 0 • A HO - ZED SENT: Signature: Da Print name //S O O o e A} Z C F Z P "- 21' Address / ) z r 5 2 4 -` CitYl,Sray zdAt 9, p, o - ALL COMMERCIAUMULTI -FA Y TENANT IMPROVEMENT /ALT' ATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER Y ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant looation(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions • 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use, only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY TIM HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY E LAW9 OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTI'I:KMIT.VOC 1/29/97 CITY OF TUKWILA. NA -IRANSMTV TRANSMIT Number: R9700825 Amount: 704.25 09/04/98 10:08 Payment Method: CHECK Notation: PCL CONSTRUCTION Init: BLH, Permit No D90-0225 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 262304-9023 Site Address: • 290 SOUTHCENCER MALL Total FeeE: 1.159.09 lhis-.Payment 704.25 Total ALL Pmts: 1:159.09 Balance: .00 1% h*****A0ri Account Code Description Amount 000/322.100 BUILDING - NONRES 699.75 000/306.904 Sr9TE BUILDING SUR-041440E 4.50 5402=09/08 /7i7. TOTAL, .704.2 1 1; ;'r k•kk 4 ,1, •A •k :% * * . * 4 A.:1 • • k • ! • : A * * * i r k • k k A . A . 4 . •k : A • * 4 k it •4 :t• k. k h •A •k A;* * k :A ".h k 4 * ;l :A: -.k . -k* ��• =Vr A CITY OF T'UKW1LA. WA :. 1 R(.r11a3MI:T, kk.A* It �S.1 It .fr *k:4 Irk Ale*3...4Ak.1, * *4 AAA tk•k.hA*A4'A TRANSMIT Number R97.007ti18.,Amo.ur ! t, `.454x84" 06/21 i4 ,■7.., Pavinq.elt' •Mel ;hod i ":CHLCI; Notatiort.. P•CL 'GO.N5T t nit.: K.JP ' : . POrmit No D98-0223 TVU DEV DEVIL OP.i4EU'I PEI 4I'F Par`Ce1' No:: . 62.304 -9023 8it'e Addrels:� 'x;3:3 SOU"IHC1 N•IER I4ALL Total Fens l.115:11:;. 4. 0.3: This - Pavmerit 4�,4 . t;a .0 To1 ALL . Pmta r 45 X14: • —Oil Ance. •7.04 25.::. kk• AdA* kkaA * *k•k'kkkkA•4`4k*.AkA4.k•A1, Alai•k“*• kit* 4* ictocAk : k *'k4,of•4.0•k kik!r4 „— Account. Code 000/345.830 • Des•cr i q't ion ::.;A n04 PLAN CHECK 7 MONRES. 45,4 FiZc Ft _ c 9, pec ion: .,• rtsif2. 5 , Ceid-ey- ... .: ,.. Specirinstructions: Date anr14_ l 0( 0 Requ.q Phone: fLog INSPECTION RECO( Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 0;a5 PERMIT NO. (206)431-3670 proved per applicable codes. El Corrections required prior to approval. COMMENTS: tOL r77 02tt OP /Lire-416e p 0 $4 .00 REINSPECTION FEE REQUIRED. Prior to in4)ec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • Receipt No: Date: COMMENTS: Ty a of ns ection: � '' M(tt PO /1',,1 T� 4 • 7 b ou t [ 0" T ^ 0k'��.-C/1,Aiv t' r /vE-- �1 G'( fr PIE- { / ts PedE7o.esso 1)E4tAQ L t 7?(-( si.ittiLb B .. .1-JQo0 B4 2- (A X99' w,. ate. -- C'c9 -AiS rA/c_ .1 a.m. P.m. Re t • rT S n4 -77/.1 ,rte - - ew.-7x mc,rx? ,Lco 1 .. 4 , P ..a. `" - I F.��� Ty a of ns ection: � '' M(tt PO /1',,1 : 72d��res ; ,� ^ AI f se. ` �✓ Date called: Special instructions: Date w nt d: � � a.m. P.m. Re t • Phone: • �: INSPECTION NO. INSPECTION REC ? Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd #100, Tjkwila, WA 98188 !8 -©zzr PERMIT NO. (206)431 -3670 pproved per applicable codes. 0 Corrections required prior to approval. MI $47.01 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Address :; o Sc m A / 1 Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: FINALAPP.FRM Authorized Signature City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name /? IMFor 6 C4 F� • Retain current inspection schedule Needs shift inspection G Approved without correction notice Approved with correction notice issued Rev. 2/19/98 Permit No.. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Date Suite # T.F.D. Form P.P. 85. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Date: Tue, 30 Jun 98 9:29:26 -0600 To: <KPETERSON @CI.TUKWILA.WA.US> From: "PAROOT" <paroot @pcl.ca> Reply -To: <paroot @pcl.ca> Errors -to: <paroot @pcl.ca> Subject: RAIN FOREST CAFE DEMO. X- Incognito -SN: 1121 X- Incognito- Version: 4.11.23 TENANT TENANT SPACE ADDRESS HIGH & MIGHTY G 704 296 SOUTHCENTER MALL AS SEEN ON TV G 708 294 SOUTHCENTER MALL GENE JUAREZ G 712 290 SOUTHCENTER MALL MARIPOSA G 716 284 SOUTHCENTER MALL WOMEN'S WORLD G 720 278 SOUTHCENTER MALL THANKS FOR YOUR HELP. PHYLLIS ROOT PCL CONSTRUCTION SERVICES, INC. 425 454 8020 PAROOT, 09:29 AN 6/30/98 , RAIN FOREST CAFE DEMO PER YOUR REQUEST, ATTACHED ARE THE ADDRESSES FOR THE TENANT. SPACES THAT WILL BE PART OF THE DEMOLITION. HAVE YOU HAD A CHANCE TO DETERMINE HOW LONG THE REVIEW PROCESS WILL. TAKE ON THIS PROJECT. Printed for Tukwila Community Development Building <tukbldge.... Dqg. OL7$ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D Oas DATE: 62 12-qi qSf PROJECT NAME: -- P10 I n-V-oiFE5T Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter Revision After Permit Is Issued DEPARTMENTS: �t7it'Ping Division ❑ L/11 TUES /THURS ROUTING: CORRECTION DETERMINATION: \ PR•ROUTE.DOC 6/98 510 Fie Prevention f Sfruct a l l q ,tfd DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: Complete 0 Incomplete ❑ Comments: Please Route ❑ Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions 0 REVIEWERS INITIALS: ms Planning Division ❑ Permit Coordinator II Not Applicable 0 No further Review Required DATE: DUE DATE: 8// 7/ Not Approved (attach comments) 0 DATE: DUE DATE: Approved ❑ Approved with Conditions ❑ A Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: tV Dear Sir: City of Tukwila Fire Department Fire Department Review Control #D98 -0225 (510) Re: Rainforest Cafe - 290 Southcenter Mall July 21, 1998 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 2. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 3. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phones (206) 5754404 • Fax (206) S754439 City of Tukwila John W Rants Mayor Fire Department Thomas P. Keefe, Fire Chief Ala The Tukwila Fire Prevention Bureau. cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (200) S754404 • Fax (206) 57.544.39 • ; ,,,...' • • • • ... • - *. - CONST CONT GENERAL REG I ST . # EXP. DATE i CC01 PCLCOSI099NW 06/01/1999 EFFECTIVE DATE 08/16/1991 P C L.CONSTRUCTION'SRVC INC • PO BOX 52868 • 1 BELLEVUE WA . .98015 ... 2868 . . Signatu Issued by DEPARTMENT OF LABOR AND INDUSTRIES . • • • I. GENERAL NOTES I. THE CONTRACT AGREEMENT. INSTRUCTIONS TO BIDDERS, AND THESE DRAWINGS SHALL BE A PART OF THE CONTRACT DOC- UMENTS AND ARE TO BE THOROUGHLY REVIEWED BY TIE CONTRACTOR AND SUBCONTRACTORS PRIOR TO BID SUBMITTAL. 2. UNLESS OTHERWISE STATED IN THE INSTRUCTIONS TO BIDDERS. THE CONTRACTOR SHALL PAY FOR ALL PERMIT FEES, INSPECTION FEES, ETC. NECESSARY FOR THE TOTAL COMPLETION OF THE WORK AS SHOWN ON THESE DRAWINGS. 3 THE CONTRACTOR AND SUBCONTRACTORS SHALL VISIT THE JOB SITE DURING THE PREPARATION OF THE BIDS AND SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY INCONSIST- ENCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE PROJECT COORDINATOR PRIOR TO THE CONTRACTORS BID SUBMITTAL. 4. ANY EXISTING FIRE PROTECTION OR ENUNCIATOR SYSTEM (1.E.. SPRINKLERS, SMOKE DETECTORS, ALARMS, ETC. ) MUST REMAIN OPERATIONAL AT ALL TIMES UNLESS OTHERWISE APPROVED IN ADVANCE BY TIE SHOPPING CENTER MANAGER. ( SEE RULES AND REGULATIONS NOTE H4. I 5. PRIOR TO BEGINNING ANY DEMOLITION OF TIE STOREFRONT AREA, THE CONTRACTOR SHALL ENSURE THAT THE STOREFRONT BAR- RICADE IS MOVED OUT APPROX. FOUR FEET INTO THE MALL. THE BARRICADE SHALL BE CONSTRUCTED AIRTIGHT WITH VISOUEEN ON THE SIDES OF THE BARRICADE TO PREVENT DUST FROM ENTERING THE MALL AND ADJOINING TENANT SPACES IN ACCORDANCE WITH THE DRAWINGS AND THE DIRECTION OF THE MALL MANAGER. 6. THE CONTRACTOR SHALL PAINT ALL NEW EXPOSED ELECTRICAL EQUIPMENT, CONDUIT. PIPING, ETC. ON TI-E OUTSIDE OF THE BUILDING TO MATCH EXISTING. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY LIGHTING AND OTER TEMPORARY UTILITIES AND SERVICES NEC- ESSARY FOR TIE COMPLETION OF THE WORK. 8. ARCHITECTS STAMP- THE ARCHITECT'S STAMP AND SIGNATURE IS VALID ONLY FOR THE ORIGINAL DATE ON THE DRAWINGS. ALL REVISIONS MUST BE INITIALED BY THE ARCHITECT TO MAKE ANY REVISIONS VALID. 9. THE ARCHITECT SIGNING THESE DRAWINGS HAS NOT INSPECTED THE PREMISES SHOWN HEREON TO DETERMINE THE PRESENCE OR ABSENCE OF ASBESTOS OR OTHER HAZARDOUS MATERIAL AND ASSUMES NO LIABILITY WITH THE RESPECT TO THE DETECTION AND / OR ABATEMENT OF SUCH MATERIALS. II. PRECONSTR. REQUIREMENTS I. PRIOR TO STARTING THE WORK, THE CONTRACTOR SHALL ARRANGE A PRE CONSTRUCTION MEETING BETWEEN TIE SHOPPING CENTER MANAGER AND THE CONTRACTOR'S SUPERINTENDENT AT THE SHOPPING CENTER OFFICES TO REVIEW TIE RULES AND REGLLAT- ICNS, DRAWINGS, AND THE CONSTRUCTION SCI- EDLLE. IN ADDITION, THE FOLLOWING MUST BE IN TIE POSSESSION OF TIE SHOPPING CENTER MANAGER BEFORE ANY WORK CAN REGIN- A. A COMPLETE LIST OF CONTRACTORS, SUBCONTRACTORS, AND SUPPLIERS TO BE USED. B. A COPY OF SAD-1 OF THE LOCAL AND STATE BUILDING PERMITS ( IF REQUIRED ) AND ANY ADDITIONAL PERMITS AS MAY BE REQUIRED BY THE GOVERNING AUTHORITIES, C. CERTIFICATES EVIDENCING TIE REQUIRED INSURANCE COVER- AGES AS SET FORTH IN THE RULES AND REGULATIONS NOTE n6. D. PERFORMANCE, LABOR AND MATERIAL PAYMENT BONDS AS SET FORTH IN TIE RULES AND REGULATIONS NOTE 41, III. RULES AND REGULATIONS I. BONDING REQUIREMENTS- TIE CONTRACTOR SHALL SECURE, PAY FOR, AND MAINTAIN A PERFORMANCE AND LABOR AND MATERIAL PAYMENT BOND IN TIE FORM OF AIA DOCUMENT A -311, FEBRUARY 1970 EDITION, IN AN AMOUNT EQUAL TO THE COST OF WORK OR TO THE TOTAL CONTRACT PRICE ( MAHIC -EVER IS THE GREATER ) AND SHALL NAME- SOUTHCENTER JOINT VENTURE, AND THC- RICHARD E. JACOBS GROUP AS AN ADDITIONAL BENEFICIARY AND SHALL BE ISSUED BY A SURETY COMPANY AUTHORIZED TO WRITE BONDS FOR THE US. GOVERNMENT FOR NO LESS THAN $2,500,000.00 2. PROTECTION OF PROPERTY- THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROVIDING THE NECESSARY RAMPS, CHUTES, COVERINGS, ETC. AS NECESSARY TO PROTECT THE PUBLIC, TIE SHOPPING CENTER, AND ANY ADJACENT TENANT PROPERTY FROM DAMAGE. SUCH DAMAGE MAY INCLUDE MERCHANDISE, FLRNITLRE AND FIX- TURES, AS WELL AS EXISTING CONSTRUCTION. ANY AND ALL REPAIR OF DAMAGE TO PROPERTY WILL BE PERFORMED AS DIRECTED BY THE PROJECT COORDINATOR AND AT THE EXPENSE OF CONTRACTOR. 3 SITE ACCESS, MATERIAL DELIVERY AND PARKING- THE CONTRACTOR SMALL BE RESPONSIBLE TO COORDINATE ALL MATERIAL DELIVERIES FOR TIE WORK. ALL DELIVERIES SHALL BE MADE THROUGH THE SERVICE DOOR OF THE TENANT SPACE IN WHICH THE WORK IS BEING PERFORMED VIA TIE ADJACENT TRUCK DOCK AND / OR SERVICE CORRIDOR. AT NO TIME WILL THE TRANSPORTATION OR DELIVERY OF MATERIALS BE ALLOWED EITHER IN OR ACROSS THE MALL PUBLIC AREA WITHOUT TIE EXPRESS WRITTEN CONSENT OF THE SHOPPING CENTER MANAGER. SPECIFIC AREAS HAVE SEEN DESIGNATED BY THE SHOPPING CENTER MANAGER FOR PARKING. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT ALL EMPLOYEES WORKING UNDER THE CONTRACT USE THE DESIGNATED PARKING AREAS. THERE WILL BE NO CONSTR- UCTION TRAILERS ALLOWED ON THE SITE. NO PARKING WILL BE ALLOWED IN ANY OF THE DRIVEWAYS, FIRE LANES, AND TRUCK DOCKS EXCEPT FOR LOADING AND UNLOADING. WORK AREA AND STORAGE- TIE CONTRACTOR'S WORK AREA WILL BE RESTRICTED TO THE TENANT SPACE IN WHICH THE WORK IS BEING PERFORMED. NO STORAGE OR WORK AREAS WILL BE ALLOWED IN THE ADJACENT TENANT SPACES. AT NO TIME ARE TIE SERVICE CORRIDORS OR TRUCK DOCKS TO BE USED AS A STORAGE OR WORK AREA. 5. TRAFFIC CONTROL- THE CONTRACTOR SHALL BE RESPONSIBLE TO TO CCO ODTTE PUBLIC AL O HE COMPLETION O TTHE WWO WERE PROTECT- TECT- ION BARRICADES AND REROUTING MUST FIRST BE APPROVED BY THE SHOPPING CENTER MANAGER. Vie-o225 INSURANCE REQUIREMENTS - THE CONTRACTOR SHALL CARRY WORKMANS COMPENSATION INSURANCE COMPLYING WITH STATE LAWS PERTAINING TO THE WORK. COMPREI- ENSIVE PUBLIC LIABILITY AND PROPERTY DAMAGE INSURANCE AND COMPREHENSIVE AUTO- MOBILE LIABILITY AND PROPERTY DAMAGE INSURANCE COVERING THE CONTRACTOR AND ITS SUBCONTRACTOR'S OPERATIONS DURING THIS CONTRACT. SAID POLICIES ARE TO BE FOR THE MIN- IMUM LIMITS OF $1,000,000,00 FOR PERSONAL INJURY AND $500.00000 FOR PROPERTY DAMAGE AND SHALL NAME SOUTHCENTER JOINT VENTURE, AND THE RICHARD E. JACOBS GROUP AS ADDITIONAL INSUREDS. CERTIFICATES SHALL BE DELIVERED TO THE SHOPPING CENTER MANAGER PRIOR TO THE COMMENCEMENT OF WORK AND SHALL BE SO NOTED THAT SUCH INSURANCE SHALL NOT BE CANCELED OR MATERIALLY CHANGED EXCEPT UPON TEN (10 ) DAYS PRIOR WRITTEN NOTIFICATION. SECURITY AND AFTER HOURS WORK- IT SHALL BE THE CONTRACTORS SOLE RESPONSIBILITY AND LIABILITY FOR THE SECURITY OF ANY MATERIALS AND / OR EQUIPMENT RELATED TO TIE W^RK. SINCE TIE SHOPPING CENTER EMPLOYS SECURITY PERSONNEL TO PROTECT THE SHOPPING CENTER PROPERTY, IT WILL BE NECESSARY TO REGISTER ANY CONSTRUCTION PERSONAL WORKING AFTER HOURS WITH THE SHOPPING CENTER MANAGER, TIE CONTRACTOR SHALL PROVIDE THE SHOPPING CENTER MANAGER WITH TI-E NAME OF ANY PERSONNEL WORKING AFTER HOURS AS WELL AS A PHONE NUMBER AT WHICH TIE CONTRACTOR'S SUPERINTENDENT MAY BE REACHED DURING THE AFTER HOURS. THE SHOPPING CENTER MANAGER WILL THEN GIVE THIS INFORMATION TO THE SECURITY SUPERVISOR. AFTER HOURS, ANY INDIVIDUALS FOLND IN THE WORK AREA NOT REGISTERED WITH SECURITY WILL BE REMOVED FROM TIE WORK AREA AND THE SITE. 8. SAFETY- THE SHOPPING CENTER MANAGER MAY STOP ANY WORK AND THE CONTRACTOR WILL CORRECT ANY ITEM WHICH MAY, IN TIE SHOPPING CENTER MANAGER'S OPINION, CAUSE INJURY OR HARM TO, TIE PUBLIC OR SHOPPING CENTER PROPERTY AND THE CONTRACTOR SHALL BE FULLY LIBEL FOR ANY COSTS OF DAMAGE OR DELAY AS A RESULT OF SUCH ACTION 9. SIGNAGE- THE CONTRACTOR IS NOT PERMITTED TO POST ANY COMPANY NAME OR SIGN ON THE STOREFRONT TEMPORARY BARRICADE OR BUILDING EXTERIOR, HOWEVER, THE CONTRACTOR SHALL POST ALL SIGNAGE AS REQUIRED BY THE SHOPPING CENTER MANAGER FOR PUBLIC SAFETY OR GENERAL WARNING, 10. BELOW GRADE CONSTRUCTION - PRIOR TO BEGINNING ANY BELOW GRADE CONSTRUCTION WORK, THE CONTRACTOR SHALL VERIFY TIE LOCATION OP ANY UNDERGROUND UTILITY SERVICES. ANY DAMAGE TO EXISTING UNDERGROUND SERVICES WILL BE REPAIRED AS DIRECTED BY THE PROJECT COORDINATOR AND CHARGED TO THE CONTRACTOR. II. INTERRUPTION OF UTILITY SERVICES- THE SHOPPING CENTER MAN- AGER MUST BE NOTIFIED AT LEAST 72 HOURS PRIOR TO ANY MODIFICATION TO UTILITY SERVICES THAT WILL TEMPORARILY INTERRUPT TIE SERVICES TO OTHER TENANTS OR TO THE SHOPPING CENTER. 12, NOISY CONSTRUCTION - THE SHOPPING CENTER MANAGER HAS EST - ABLISHEDWORKINIG HOURS WHEN TIE CONTRACTOR MAY PERFORM 'NOISY CONSTRUCTION'. ( CHECK WITH TI-E SHOPPING CENTER MANAGER FOR THESE RESTRICTED HOURS I TI-E SHOPPING CENTER MANAGER RESERVES THE RIGHT TO ORDER AN IMMEDIATE HALT TO ANY WORK THAT IS, IN THE SHOPPING CENTER MANAGER'S OPINION, DISRUPTIVE TO THE NORMAL OPERAT- ION OF TIE ADJACENT TENANTS AND / OR THE SHOPPING CENTER. 13. TRASH REMOVAL- ALL TRASH WILL BE CONFINED TO TIE TENANT SPACE IN WHICH THE WORK IS BEING PERFORMED ( OR OTHERWISE AS DIRECTED BY THE SHOPPING CENTER MANAGER 1 AND REMOVED AT THE ENO OF EACH AND EVERY DAY BY THE CONTRACTOR, ANY TRASH FOLND IN THE SERVICE CORRIDORS, TRUCK DOCKS, ADJACENT TENANT SPACES, AND / OR PUBLIC AREAS WILL BE REMOVED BY THE SHOPPING CENTER MANAGER AND BILLED TO THE CONTRACTOR AT A RATE OF $50,00 PER MAN HOUR PLUS EQUIP- MENT COSTS. ( ANY TRASH DLMPSTER LOCATION MUST FIRST RECEIVE TI-E PRIOR APPROVAL OF THE SHOPPING CENTER MGR, UNDER NO CIRCUMSTANCES ASE THE SHOPPING CENTER TRASH COMPACTORS TO BE USED BY THE CONTRACTOR, 14. SPRINKLER SYSTEM - THE CONTRACTOR MUST NOTIFY THE SHOPPING CENTER MANAGER AT LEAST 48 HOLRS IN ADVANCE OF MAKING ANY MODIFICATION TO THE EXISTING FIRE PROTECTION SYSTEMS. NO SHOPPING CENTER SPRINKLER SYSTEM WILL BE LEFT DRAINED OVER NIGHT. ALL SPRINKLERS WILL BE CHARGED AND OPERATIONAL WFEN TIE WORKERS LEAVE FOR 7IB NIGHT. IN THE EVENT THAT THE WORK REQUIRES A MODIFICATION TO THE EXISTING FIRE PROTECTION SYSTEM, THE CONTRACTOR SHALL BE REQUIRED TO OBTAIN THE OWNERS FIRE INSURANCE UNDERWRITER'S APPROVAL PRIOR TO PERFORMING SUCH MODIFICATION, TO OBTAIN APPROVAL, SUBMIT SEVEN BLUE LINE PRINTS OF SHOP DRAWINGS TO- FACTORY MJRIAL DISTRICT OFFICE TI-E PLAZA CENTER BUILDING, SUITE 1105 10900 NE. 8TH STREET BELLEVUE, WASHINGTON 98004 TELE' ( 206 1 454 -3951 INDEX NO' 78849.18 AND ONE ADDITIONAL BLUE LINE PRINT TO THE PROJECT COORDIN- ATOR. AFTER RECEIVING PROTECTION MJTUAL'S APPROVAL, FORWARD ONE REPRODUCIBLE SEPIA OF THE APPROVED DESIGN AND TWO BLUE LINE PRINTS BEARING TFE APPROVAL STAMP OF TI-E PROJECT COORDINATOR. 15. AMERICANS WITH DISABILITIES ACT - TENANTS SHALL BE RESPON- SIBLE FOR MEETING ALL CURRENT DESIGN CRITERIA AS IT RELATES TO 71-E 'AMERICANS WITH DISABILITIES ACT', LATEST EDITION. 16. THE CONTRACTOR IS RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, AND SEQUENCE OF CONSTRUCTION, AS WELL AS FOR TIE SAFETY OF THE WORKERS. 17. TIE ARCHITECTS BASIC SERVICES SHALL NOT INCLUDE THE CONSTRUCTION PHASE SERVICES. THE OWNER SHALL BE RESPON- SIBLE FOR INTERPRETING THE CONTRACT DOCUMENTS, REVIEWING SUBMITTALS, CERTIFYING PAYMENTS TO TIE CONTRACTOR AND RESPONSIBILITY CONTRACTOR'S IISCINGGCORRECTING TI MITI ERRORS, INCONSISTENCIES, OR OMISSIONS. 18. LIEN WAIVERS AND AFFIDAVITS- THE CONTRACTOR WILL BE REQUIRED TO SUBMIT THE FOLLOWING ITEMS AT THE END OF CONSTRUCTION ( FORMS ARE AVAILABLE FROM THE LANDLORD I- A. AN ORIGINAL NOTARIZED 'GE NERAL CONTRACTORS AFFIDAVIT AND FINAL WAIVER OF LIEN' B. TI-E ORIGINAL SIGNED AND NOTARIZED 'SUBCONTRACTORS AFFIDAVIT AND WAIVER OF LIEN' FOR EACH CONTRACTOR. 19. CONCRETE- CONCRETE MUST BE SAW -CUT OR CORE-DRILLED ( NO JACK - HAMMERING OR BREAKING OF CONCRETE IS PERMITTED ) PRIOR APPROVAL MUST BE OBTAINED FROM LANDLORD PRIOR TO PENETRATING ANY STRUCTURAL OR STRUCTURALLY REINFORCED CONCRETE 20. BELOW GRADE CONSTRUCTION - PRIOR TO BEGINNING ANY BELOW GRADE CONSTRUCTION WORK, THE CONTRACTOR MUST MEET WITH THE LANDLORD TO REVIEW THE LOCATIONS OF ANY UNDERGROUND UTILITY SERVICES THAT MAY BE LOCATED IN TI-E PREMISES. ANY BELOW GRADE CONSTRUCTION MUST BE INSPECTED BY THE LANDLORD PRIOR TO BACKFILLINIG. 21. LANDLORD INSPECTIONS- THE TENANT'S CONSTRUCTION WORK WILL BE OBSERVED PERIODICALLY BY TIE LANDLORD TO VERIFY THAT THE WORK IS BEING CONSTRUCTED AS SET FORTH IN THE TENANT'S LEASE, TENANT MANUAL, TYPICAL TENANT DRAWINGS, AND LAND- LORD APPROVED TENANT DRAWINGS, 22, TEMPORARY TOILET- IT WILL BE THE RESPONSIBILITY OF THE CON- TRACTOR TO PROVIDE ADEQUATE TOILET FACILITIES FOR ALL EMPLOYEES WORKING WITHIN TI-E PREMISES TIE SHOPPING CENTER TOILET FACILITIES WILL NOT BE AVAILABLE FOR CONTRACTORS USE UNLESS SPECIFICALLY AUTHORIZED BY THE LANDLORD, THE LOCATION FOR A TEMPORARY TOILET SHALL BE APPROVED BY THE LANDLORD. 0 Ll otk LOCATION OF WORK UNITS G -704 TO 0-720. SEARS KEY LOCATOR PLAN SCALE NO SCALE DWG. NO. TS -I SCOPE OF WORK 5310 Pe JCPENNEY RENSLO AO ILL 5 -4 -98 OB NUMBER: DA TC 5 -26 -98 SC_G712T MALL AND PROJECT NAME PROJECT CONTACTS I. PROJECT COORDINATOR' 2. ARCHITECTURAL COORDINATOR' 3. MECH AND ELECT ENGINEER 4. SHOPPING CENTER MANAGER' 5, MALL MAINTENANCE DIRECTOR' SOUTHCENTER MALL COMBINE UNITS G -704 THRI UNITS G -720 INTO UNIT G-712 THE "SCOPE OF WORK" FOR THIS PROJECT SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING ITEMS' 0 PROVIDE CONSTRUCTION BARRICADE ACROSS STOREFRONT AS DIRECTED BY THE MALL MANAGER AND PROJECT COORDINATOR. 02 PROVIDE DEMOLITION OF THE PREMISES AS SHOWN AND AS REQUIRED TO DEVELOP A SHELL SPACE FOR FUTURE TENANT. BRAD SANDERS RUDY PLASKO BYERS- STECKLOW MIKE_ HANSEN JERE WESTLOTORN DRAWING INDEX TITLE SHEET, GENERAL NOTES, KEY PLAN, DETAIL DEMOLITION FLOOR PLAN CI ° II LLI C:7 JI =1=_I �7 11; il IC 1 JIIL /30 1008 ( 440 ) 892 -2705 ( 440 ) 871-4800 ( 216 ) 781 -7800 ( 206 ) 246-0423 1 206 ) 246 -0423 MERVYN'S SED CITY OFTD JUN 291998 PERMIT RENTER REVISIONS W H Luz Z J Q (I)c 11.1 111 L - Ui 1 1 I-- C9 C TS -1 0 Na SOUTHCENTER C -712 oqc- oaa5 0 f 133'-2' 0 T EXISTING TENANT PROSSER PIANO' TO REMAIN. LNIT G -700 2q8-o225 LNIT 0 -704 DEMO EXISTING BUILDING CON- STRUCTION TO REMAIN, :2. qo 137 -0' EXTENT OF DEMOLITION DEMOLITION FLOOR PLAN SCALE. 1/8W-0* 117.0' OUTLINE OF CANOPY ABOVE CONCRETE WALK TO REMAIN. ALL STEEL COLUMNS AND ADJACENT LNDER FLOOR EXHAUSTER TO REMAIN TYPICAL OF 6. 60 N t —G- 9 N 9 (NIT G -724 O EXTENDED STOREFRONT LEASE LINE. ORIGINAL STOREFRONT LEASE LINE. E MEN TRASH ROOM WOMEN EXTENT OF DEMOLITION IS SHOWN HATCHED OR DASHED ON THE PLAN. ALL STRUCTURAL STEEL AND RELATED FIREPROOFING ( IF ANY ) SHALL REMAIN INTACT, REPAIR ANY DAMAGED AREAS BACK TO ORIGINAL CONSTRUCTION CONDITIONS, LANDLORD'S CONTRACTOR SHALL DEMO OUT ALL EXISTING TENANT CONSTRUCTION INCLUDING STOREFRONTS TO DEVELOP A BUILDING'SIELL' CONDITION. DEMO FLOORS DOWN TO ROUGH CONCRETE, DEMO OUT ALL INTERIOR WALLS AND DEMO PER- IMETER WALLS DOWN TO ROUGH GYPSUM BOARD. DEMO CEILINGS / SOFFITS ( EXCEPT AT SPRINKLER HEADS I. DUCT WORK, PIPING, CONDUIT, ETC. DOWN TO EXPOSED BUILDING STRUCTURE AND BUILDING SYSTEMS / UTILITIES, DEMO CEILINGS / SOFFITS ( EXCEPT AT SPRINKLER HEADS ). DUCT WORK, PIPING, CONDUIT. ETC. DOWN TO EXPOSED BUILDING STRUCTURE AND BUILDING SYSTEMS / UTILITIES. TI-E EXISTING LANDLORD BUILDING STRUCTURE AND BUILDING SYSTEMS / UTILITIES SHALL REMAIN INTACT AND OPERATIONAL INCLUDING FIRE PROTECTION SYSTEMS ( SPRINKLER ), AT ALL TIMES, PATCH BACK / REPAIR ANY DAMAGE THAT MAY BE DONE TO TNT LANDLORD'S BUILDING STRUCTURE AND BUILDING SYSTEMS / BUILDING UTILITIES, UPON COMPLETION OF DEMOLITION, THIS CONTRACTOR TO VERIFY ALL BUILDING SYSTEMS AND RELATED COMPONENTS WITH MALL MANAGEMENT PRIOR TO ANY DEMOLITION. BUILDING SYSTEMS AND COMPONENTS SHALL REMAIN INTACT AND OPERATIONAL AT ALL TIMES LNIT G-728 DEMOLITION NOTES CI;/ 111 IIII(WILN Ppp 0 JUL 30 1900 17Uiil'jIN(', DIV ISI()I`� - CITY OPTUKWILA JUN 2 9 1999 PEWIT centres REVISIONS -J 2 Z 0 Q z W Z U§ " F — // M! S S U 0 CRAYON LI, DAM 5-I -98 SCAM JOU NUMBER. 5 -26-98 CAP c•o PN FILDIAMILI SC_G712 A -1 SOUTHCENTER G -712