Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D98-0236 - TELECOM LABS - OFFICE SPACE
702 Industry Dr. Telecom Labs, Inc. City of Tukwila ( t ` (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 252304 -9008 Permit No: D98 -0236 Address: 702 INDUSTRY DR Status: ISSUED Suite No: Issued: 07/20/1998 Location: Expires: 01/04/1999 Category: AOFF Type: DEVPERM Zoning: CM Const Type: Occupancy: OFFICE Gas /Elec.: UBC: 1994 Units: 001 Fire Protection: AUTO FIRE ALARM Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: Y Streams: Contractor License No: OCCUPANT TELECOM LABS INC 702 INDUSTRY DR, TUKWILA WA 98032 OWNER SBP GENERAL PARTNERSHIP 617 INDUSTRY DR, TUKWILA WA 98188 CONTACT DOUG GRAHAM Phone: 206 - 575 -9100 647 INDUSTRY DR, TUKWILA WA 98188 r**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REARRANGE OFFICE SPACE. r**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 10,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N a**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 272.21 r*************************************** J************* / * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:_ Signature: Print Name: /' DEVELOPMENT PERMIT I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Date: -- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/'Tenant: .. Lt: c v.0 0,6 S 1 - G Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel el-Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family a Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel aOffice ❑ School /College /University ❑ Other Value of Construction: / 0 K, Site Address: 70 2- /1),9 v 5'T'1L., t- 0 t2. -C. City State /Zip: - tvw� 4 UV ct-d qtr W8" Tax Parcel Number: 2 2 - -0'61:1 Property Owner: / [.4acL4.4cw/) Go ct.41t.Ec.4. 4c. 4.1.44. 5,'1(4 . Phone: Street Address: � /s, ( 7 ( N D LI NT rte[ !) e.4.4 'Pew, c.1 City State /Zip: cuA oi TI r k Fax #: Contractor: Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: .at- G/-4'14a -" Phone: Ze7G Sig q, Street Address: 64 7 (M D v - - :; Tt'j De-1 7U1 4•4 City State /Zip: w4 r ef 8 F Fax #: Z :5 G S75 ?Fa c Description of work to be done: I_`L. 4 .011,0 UT-Pt ce . _5 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel el-Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family a Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel aOffice ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes i❑ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes ®' no Existing fire protection features: ❑ sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: Z `Z existing Area of Construction: (sq. ft.) Zorn Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ® no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUIr'WLA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE.FOLLOWING :' (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous CTPERMIT.DOC 1/29/97 ProjectNunn vi Permit Number: ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Appli taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AUTHORIZED AGENT: Signature: y �, ti Date: 3 .. `t 1S Print name: d (-- G 1 Phone: I '4_4'6-' 5-7 5- fir'" 1 Fax #: Z , t. •5-7 5 ci`ov Address City /St to /Zi ALL COMMERCIAUMULTI -F4 r ILY TENANT IMPROVEMENT /ALT RATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: AIL "on AO 6S TO'BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER D ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN Y BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include • ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CT1'EIMIT.DOC 1/29/97 ..■44 ;A . 4:4 ;),4;4:4v * ** COMMUN DEVELOPMENT 4.*** * **.*.*14, TRA.NSMIT, R97007971.:AMoitn.ton 166..75 07/20/98 i430 • . PaYmerit MethOd•:: CHECK • Nat'at on: ., LAP 8..••3:•NC"....'• Permit No 098-0236: .• Type: DEVF'ERM DEVELOPMENT PERMIT l'ai-cel Nor, 252304-9008 , •.' • . Site Address: 702 INDUS • Total Fees: : '272.21 This Payment; n.1.66.75 Total ALL Pmts; :272.21' l31uce. 00 A*11*164eicir•A**A.*****./t4r**41 ic*.A vie%ti, Accourvt Code Description Amount 000/322.100 BUILDING - NONRES ••••' ••• 1'62.25 000/386.904 STATE BUILDING 3URC1-1•ARGE 4.O , ' ckA *k * *k *A *,1 ** ** * 'CITY 'OF TLi }WILA; W * * *4•* * *; *•k* * *71,4A* TRANSMIT Number: Payment. Method: Permit NC): Parcel 'No: : Site Address: THIS Pavmerit * * * * * *k *•.k *r * *+ * *d. Account Code '000/34l30 , PW DCD 105.46 PW DCD 0.01 CHECK 105.47 07/02/98 19 12:52 0097 3375 • I) e i.Ut i on PLAN CHECK * * **11 * ** h•* *;t*. *•!•• * * ***AA•. *,1 * *A * *, ' TRAIT *.1 * * *4* ** * ** * k.1.* * * ** *'* i?kyl' ** * *A•* * * * * *•* *.1*k *.A.* tik *. *k** * *:1* ** A4 * ** R9.700790 •,Amount:: CHECK Not.atiari: D'i48' 023b . Tvele: DEVPERM • DEVELOPMENT '2 2304• -90.08 702 INDUSTRY 0 5.11 10 Tot * *A *• *A * *A, * *** ** **. 105.46 '0 /3019'8 , :,1 ::1 3 I) & S INTERN TIO 'In it. E3LH PER 14I: Total Fees::. 2?2 21 al AL.L `PmtS g l arlc c w 1(b 7t;: Amaunt HONRES • COMMENTS: Type ic tose � ME-. 1-‘)6 l6SCr,BE... tJn.:( 7U(5 PLe( / r a.-„ifs 4.f7 / )04E y oceetz.6. f 7;o-ic.rs CIA.1B 5-'9 "� [ / Reques r: e_nr M . t' `-► /��f- Phone: MiX t 00 c'ni DA-Al I t Al, f i r P / 6 . eCOYV\. ! S f C.. Type ic tose � Ad s: 02� (DvsTq Date called: Special instructions: Date wan / 60 a.m. p.m. [ / Reques r: e_nr M . t' `-► /��f- Phone: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Zc 43/-36 '70 PERMIT NO. (206)431 -3670 0 Approved per applicable codes. 0 Corrections required prior to approval. 0 $47.00 REINS CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Sout center Blvd., Suite 100. Call to schedule reinspection, Receipt No: Date v� /p Date: Project,. i 1-e tcow. 1.-•ctt9s Type of Inspedion: r • Address: 701 Iv4v5Ary-.Zi Date called: 1 1-3i— 2,000 Special instructions: I Date wanted: .2- 2- _woo Requester r va LOYAKCA 1.1.N Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 0 Approved per applicable codes. COMMENTS: frier bo P'/Ie 1/1/ A /1 1-14'ci friA4-t&■CX) 77,-)26‘-c 9,464e" 4/0 001,041(S 404/zietetb ppi-ei- 4 5, 1 - r A 7o 7 P1))176 El $4700 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: •• 1, \ INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. PERMIT NO. (206)431-3670 • • Project: Type of inspection: Address. Goys - ,�,f / Date called: Tr /per Special instructions: r" Date wanted: �/ �rGu /�,fr a.m. P.m. Requester: / Phone No.: ,./.-.--- _ 9 / 6 C) INSPECTION RECORD U Retain a copy with permit INSPECT! NO, CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. II 'Y :g -oz31.0 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. 'COMMENTS: 4e.- (, 19e4,.0 • 4/,9401 4ivar $42.00'REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection, Receipt No.: Date: r'1I III III 111111111111111111III kT- 11111 iii 1 iiiii 11 ° f�HH+FHIIINNII Tenant : DBA: The Premises and the Building us shown above are approximations. LEASE AGREEMENT EXHIBIT A SITE PLAN Demised Premises: approximately square feel Frontage: approximately lineal feet Maximum Depth: approximately lineal feet 11RC/1. 212 i) o 2-3 (cs -A- 'T'enant's In itials Ia1nd lord 's initials TELECONILABS INC Bill Rambo 6300 Southcenter Boulevard Suite # 100 Tukwila, WA 98188 RE: Permit Status D98 -0236 Dear Mr Rambo: Request that permit D98 -0236 be closed by your department. The intended remodeling was never initiated, partitions under 5'9" were used. Sincerely Daniel R. Minihan TLI, Facilities Project Manager (206)575 -9100 700 Industry Drive, Seattle, Washington 98188 I Tel 206•575.9100 I Fax 2069575.9900 January 20, 2000 Doug Graham 647 Industry Dr Tukwila, WA 98188 Dear Mr Graham: Sincerely, . Ciz of Tukwila Department of Community Development RE: Permit Status D98 -0236 702 Industry Dr In reviewing our current permit files, it appears that your permit for an office rearrange, issued on July 20, 1998, has not received a fmal inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. - Bill Rambo Permit Technician Xc: Permit File No. D98 -0236 Duane Griffin, Building Official Steven M.- Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206.431.3665 ACTIVITY NUMBER: D98 -0236 DATE: 6 -30 -98 PROJECT NAME: TELECOM LABS INC XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter Revision After Permit Is Issued DEPARTMENTS: ing - i 2 c ' PbicWr n � y ek- 1- 7-61,Y uil pp, nu PLAN REVIEW /�OTINUSKIP DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Incomplete ❑ Comments: Fire evention Plan `ni g Division ❑ tructur1I ' ❑ Permit Coordinator qpi DUE DATE: 7 - - 98 Not Applicable ❑ TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 7 -30 -98 Approved ❑ Approved with Conditions \PR•ROUTE.DOC 6/98 Approved ❑ Approved with Conditions❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE. Dear Sir: City of Tukwila Fire Department Fire Department Review Control #D98 -0236 (512) Re: Telecom Labs, Inc. - 702 Industry Drive July 7, 1998. John W. Rants, Mayor Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Local U.L. central station supervision is required: (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 1206) 575.4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number. 2 (City Ordinance #1742) 3. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 4. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) John W Rants, Mayor Thomas P. Keefe, Fire Chief This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Preve ion Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax: (206) 5754439 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON COUNTY OF KING 1. I have made application fora building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. . 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. i t /' 3 , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. VI' -, 0 POD �C n., . AFFCONT.DOC 5/29/96 CITY OF TU 'MLA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 s s. tates as follows: APPLICANT Signed and sworn to before me this day of JA.u7) , la N ARY PUBLIC in and for the State of Washington, County. Name as commissioned: e/- trJl'Y? My commission expires: C 9l residing at H -4 18.27.090 Exemptions. This chapr • shall not apply to: of 1. An authorized representative othe United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT.DOC 5/29/96 of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; . 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. wners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an . electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 11 An owner who contracts for a project with a registered contractor; Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway.projects who have been prequalified as required by t taapter'13 Qf.the Laws of 1961, RCW 47.28.070 with the department of transportation to perform higt•jvyaysdonstruction, reconstruction, or maintenance work. b OFFI SUE I te �v� LOSSY CONFERENCE ROOM OF ICE DOUG Ii" WORK AREA 2 RECEPTION 1> [slt.K - EXISTIMG IZ EXIST UNI -SEX RESTRM. EIRE dl AREA UNI SEX RES WORK AREA 1 ,la 6 EXERCISE RM. RELOCATED JO ST1 DELETED /�* \ RESTRM. `0• r EXIST SW 4 CAB / 1 ti 2 EXISTING MEW 4 1. A EXISTING 1 I d3 c C� c SALES OFFICE It WA HOUSE; S TORAGE RM t ty 7 7 .0 7 D98 -0236 EXPIRED 11 n ■ h Z MIS t4 Z,S 31 TECI4 WORK ROOM © ft. c. ENTRY 3 r —r-1 a �\ r 32 ENTRY V op 6 PAD ,, EXISTING WALLS c:P F TO REMAIN � � r ' 6M NEW WALLS S' I-IT WALLS � � 3 It4SpiacTiON to/ Me 2320 •DQuggi- V-AsrMitt44 St et. col.Amat ug cse ' 26•G. s ` FILE COPY I understand that the Plan Check appra::'s cro subjoct to errors and omissions and approval of plans does not authorise die violation of any tad code or caftan& Hsouipt of contractor's of approved pNJre By Date Permit No. CITY OF TUKWILA APPROVED JUL 1 61993 AS NO1Lli rrAnf._'N i RECEIVED CITY OF ruICWrLA Ji1Pd ■ 0 1998 _RMIT CENTER 5 -16 -98