Loading...
HomeMy WebLinkAboutPermit D98-0242 - SPIDER STAGING - STORAGE RACKSD98 -0242 i 365 Upland Dr. Spider Staging City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 883650 -0070 Address: 365 UPLAND DR Suite No: Location: Category: AWSE Type: DEVPERM Zoning: TUC Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Contractor License No: NORTHSCO24DT OCCUPANT OWNER CONTRACTOR CONTACT Permit No: Status: Issued: Expires: D98 -0242 ISSUED 07/16/1998 01/12/1999 Occupancy: WAREHOUSE UBC: 1997 Fire Protection: SPRINKLERS East: .0 West: .0 SPIDER STAGING 365 UPLAND DR, TUKWILA WA 98188 BOEING OREGON MESABI TRUST 1325 - FOURTH AVE., SEATTLE WA 98101 NORTHERN STEEL COMPANY 22257 WEST VALLEY HY, KENT WA 98032 CAREY FERGUSON 22257 WEST VALLEY HY, KENT WA 98032 *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL PALLET STORAGE RACK IN TWO PHASES. *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 488.36 :*************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Streams: Phone: 206 - 575 -1671 Phone: 206 - 575 -1671 End Time: Fill: Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development per it. Signature:__ _ Date:__ Print Name:Gti!g �✓ �,��� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 365 UPLAND CSR. Suite: Tenant: Type: DEVPERM Parcel #: 383650 -0070 Permit. No: D98-0242 Status: ISSUED Applied: 07/07/1998 Issued: 07/16/1998 . k•kk•kk•k•k•k•k * *•k*•*•k•k•k* ****•k•k•k*k*•k*•k ***•* **•k*•k*•k•k*•b'k**•*•k*k*•kkk. ***k*k ****"kk*•k** Permit Conditions: 1. No changes wi 1 i be; made to the plans, unless approved by the Architect or Engineer and the Tukwila .Building Division. 2. All permits. inspection :records,.' °.and.•a;t;Proved plans shall be available at the job site prior to the start of any con- struction. These ;documents <ar•e toAle maintained-.and avail able until final inspection approval is granted.'.': 3. All construction to ,:be done in conformance with aiipr,oved plans and requirements of the Uniform Building: Code; (1994 Edition):as amended. Uniforth Mechanica-1.Code: (1994,Edition). and Washington State Energy. Code (1994 Edition).'';:. 4. Validity of Permit The issuance. of a permit, of '..aporova1 Fiat plans, specifications, and computations shall not .be;, con strued to be a permit tor•, or an .approval ot, any v;ioia,tionk,, of any of,the i,rovisions of the :,bu i Iding code or :of ,any ... others ordinance of the, jurisdiction. No permit presurni,fg give-.authority to violate or cancel "the provisions ot::th=is code _,__l, , CITY OF TUIO'OILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 mmercia OR_STAFF;USE :DNLY Project Number: Permit Number: Pele-10420 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ilication Project Name/Tenant: Existing use: ❑ Retail ❑ Restaurant ❑ Multi - family . Warehouse El Hospital ❑ Church ❑ Manufacturing El Motel /Hotel ,to Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ,0 Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel fa Office ❑ School /College /University ❑ Other Value of Construction: o-e Site Address: d �3�: -'5- (),() (c. -� i J „City State /Zip: . a') , Tax Parcel Number: / 1 883c,,so -oo70 _ Property Owner: - Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on se•arate 8 1/2 ��,,77 in the building? ❑ yes :t�.r no X 11 .a•er indicatin• • uantities & Material Safet Data Sheets Phone:. `. Street Address: (-- ° City State /Zip: Fax #: f V o ' , / �r 1� J i 40 / Phone: ,-) v , , -5 -7,"5 /C Y-1 Street Address: ,,P- 5`7 iii VA -462.7 Yi 2 City Stag /Zip: C. 1t-/ 11-2/1 • >le6- Fax #: � 06, S" �j . 673D 6 Architect: / l / Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #l: Contact Person: �— K : k . if--P ke t� -Cc— : n .1'1 Phone: ? S 3 /L?/ X ,),) / Street Address: .125- w : L 4.,. , , ,,� -a..- r,..? City State /Zip: . 6 Y...2 Fax #: CDC) o 5:7 � " O 6 Description of woo k to be done: /a-- Existing use: ❑ Retail ❑ Restaurant ❑ Multi - family . Warehouse El Hospital ❑ Church ❑ Manufacturing El Motel /Hotel ,to Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ,0 Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel fa Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes 11 no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? J. yes ❑ no Existing fire protection features: gil. sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 0 fi(') existing Area of Construction: (sq. ft.) Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on se•arate 8 1/2 ��,,77 in the building? ❑ yes :t�.r no X 11 .a•er indicatin• • uantities & Material Safet Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: ❑ Land Altering 0 Cut ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Water Meter /Exempt #: ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Flood Control Zone Size(s): cubic yds. 0 Fill cubic yds. ❑ Sewer Main Extension ❑ Street Use ❑ Water Main Extension Size(s): 0 Deduct Size(s): Size(s): Est. quantity: ❑ Miscellaneous ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale application accepted: CTPERMIT.DOC 1/29/97 Date application expires: Appl taken by: (initials) .PLEASE, SIGN BACKOF'APP4ICATION:FC?RM COMMEI. CIAL MULTI -F ILY TENANT IMPROVEMENT' 4L ° ATION'PERMIT APPLICATIONS.: 'MUST BE SUBMITTED WITH THE :FOLL•OWING:... :: • All DRAWINGS T&BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ✓ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ✓ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Complete Legal Description 71 ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ J71 Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ El Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. rr ❑ Indicate proposed construction of tenant space or addition and walls being demolished tJ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ® Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent if the applicant is other than the owner, registered architectengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal i HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW 7R OR AUTHORIZED AGENT: Signature: - Date: )- — 7- M. Print name: r7t Fax #: Address.70 7 71} (4_4 A ci City /State /Zip 16:444_ t.,4 7i63� CTPERMIT.DOC 1/29/97 , • +++A*+k+A*A++A**+**.++A+A7+***********^+++*A**+4+k* � lRANSM�T. ITV OF TUKNILA. 4[A ` ` �� ` � � � ,� ' ^++++a++A***�+*+4+*+++«****a++*+***++***+****a4*+^+**A+A***+ TRONSMIT Number: R9700795Amount: . 297.75 07/16/98 14:15 Payment Method: 3336 Notationa NORTHERN STEEL Init: TICE Permit No: D98~0242 Tvpe: DEVPE8N DEVELOPMENT PERMIT Parcel No: 883650-0070 � Site Addre‘l:s: 365 UPLAND DR • Total Fees: 488~36 This Pavment '297.7' .Total ALL Tints: 488.36 • Balance: �' ` *kA�*+*�4**^a�**�**o+*a��*,+A+a*+*aA�++*a*+«+o*A*+4�+***** Account Code 000/322.100 000/386.904 -Descrjotion � BUILDING - KDNRE8 STATE BUILDING SURCHARGE` Amount � 293.25 4.50 :'.TT Y OF TUKVIlLA WA _ TRANSMIT *A***A*Akk***A**Ai:****A*************A*****4**A*A*A*A*.A***46(***** TRANSMIT Number': R9700792 Amummt: .190.61 07/07/98 14:45 Pavment Method: CHECK Notation: NORTHEMSTEEL init: 4304 Permit No: D93-0242 "Fvoe:. DEVPERM DEVELOPMtNT Parcel No: 883650-0070. Site Addreset .365 IJPLAND.D11. Total.Fee5: 483AG This:, Pavmemt 190.61 Total. ALL Pmts:: 190.61 .. .'' a'alancei:. ..2.93.25:' Account Cpde oescr ij) t i on •, ' - Amount 000/345.830 PLAN CHECK, - NOMRES ' 3520 .07/09 717 13, T 1.90,61 h' K INSPECTION RECORD - t. Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 3670 Project: V !- /� v'f�l� _Type of inspectidC C Date called: '4 „ ) /// Address: v Special instructions: Datewanted:0_4 0 t2 CC77 m. Requester: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: CAI Date: Fl $42.00 REIN$PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: ,,.v,,,t- .c�.- t�,.ras��rr«'S ' �' r., m..-: �c. ��TS ;..:x•..^+axs;;f...;n,�m -b••x r.,-, Tn. , +-v,.���:�rv�.�,T- ay..:..✓t��r �J INSPECTION NO. INSPECTION RECORD r� Retain a copy with permit . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,' Tukwila, WA 9818 PERMIT NO. (206) 431 -3670 Project: Type of inspection: 4 Addreg-7 Date called: S !al instrucjibbns: Date wanted ^°. � � a.m. p.m. Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .., ';L; '; ��^ .�l :.T"S:'^'_.. �2i< ., < <'t[: :"..:'��: �'��•.:'L: ;A�i .. .,, '*, +_,•R':.r, �". !'J"i<'.';.K•.,.:< INSPECTION RECORD Retain a copy with permi INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Project: S. , n S/' - C-V...Q4c 6 cal< Type of inspectio : e� __, 4/) Address c "2" C c Ct.. -tw C Date called: g z.- Special instructions: �/ �•j c r a.m. Date wanted: G1 i P.m. .m. Requester: ,� *`f e, Phone No.: • ,e7, Approved per applicable codes. Corrections required prior to approval. COMMENTS: $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188�J \� (206) 431 -3670 INSPECTION RECORD � Retain a copy with permit k.... Zt(2 PERMIT NO. Project: s4_,_ Type of inspection: AC � ! , Address: / / s � / CL' Date called: Special instructions: ;9 ��� / Date wanted: 7 _�� aaTm: Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7/�5c / 0 Inspector: Date: 72g-r5 $42.00 REINSPECTION WEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: l City of Tukwila Fire Department John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name "l r)f)( /'Vc Address 2(C 5 („,� ) LA/Al) • 1)/2• Retain current inspection schedule Needs shift inspection Thomas P. Keefe, Fire Chief Permit No. -i%U Suite # X Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: / Permits: J Authori ze`d Signature ((-1 f./4 471, D 67/5/9 e FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 BY /7- CHKD. BY DATE DATE- ag ATE PROJECT PWW"i :7..4 +14 U SHEET NO. / OF 7 -ru ica.)1 (.4.t ,WA JOB NO. 9770 P 4-cL3 Fa% S OE -' ST L,. A TUw314.13 lJ Ar \I = (7, S. c0,1' t .i. W T2kri!SV_ - &R.ArcD _ i ' 4.0 .4 ■• as vrt -s ;- e> akAga✓J. / �.M.r,4 � y ,126G0 a <S G /S'r 6; t l�'+ Ca = ©. 33 Sas A4 .c. loci& 3 A-,14 Sou_ pg.csrti.g. Sc Like t o& eL. r-'i1- RA t c DC LcA . "rR -k.15 V . 7) CR- 20 TA-u- 4-L A-Ots AiU ,�u� Sf UA-L Vr = 0,/339 W = .1339► °5R 2.10 j.40(o e )15..2 6$ kj .. Z4(.33 k'" 44 - ¢t sees (1- z 4,e)14- T V z v.1a�` %Cow• f' (t '' S •ZS14 At COMP EXPIRES. 7 /14/0 0 J Pc. ZJI.ZG14 I # # 1.0A-0 11# L6/ El- v&I Ly ' /r,.. = D . Z ai @ 240 T Z 0,5514 V . P, )4- / cat .2- V2 x 414" /4 1-r KA) IK 604:75 ax x.716 x o.M.* ).30k VA . 2 k /. 34 . o.87S f 3.221c gLol 3`' +s) ft71 -84 s ?A' �r c� 4 6 2.7 w 014.6 -t3T SPeci 1 S-P Ec-rc o . a.7 G (nIA-24) ek rn, 4 _ /.4-oC /312.44.,e = 5' 4.8g" 139.4C& (' 2.03 ISR4 ces s t4- GA iYt3 (k-L(r) = ) 3 5.74 - ei'Pr y. _37.85 ,.• 1- 0 RECEIVED CITY OF TUKWILA - 7 1998 PERMIT CENTER 6.84 -I Cie. Lc)) ?, 24 1-. r $.24.0.2339, 4/3 3,)tr(c• 7 P.: BY 67k, DATE r - 9g. PROJECT SHEET NO. .2. OF CHKD. BY DATE JOB NO. 9x70 5kst- pL14ref ca-6 5.0tL ; m4 tAo Pe_ : l 1.24 4 ktt- J ? 7 18 /a,, _ z( z a . 402 cam: kft,.ow -Fr a • 3 CG 413 a ) , 0 if- 4.Z $f L ft At - 4.19Z (2.0) b. 70f- 4'"/" /Z01 -6 3 9.366" F �'ri ru,k- f - 3l� -" _ 4 3 5647picr v4- / S 4.4-%•71 60.5 tii 2S'o Pr? l C•-Ai Gam& A2t64/ -. -. /14 I° P.515' k'/, 9.5 5 = ca.) L l Ia- L. trz '�'A = I • s 4/3 2# o kSrrr q a 9,)7? 2. a4- 23,856" .5.0u- 6/1.44. Ab = 2-71P.6 x_ 50.856 7)44 5.969 ff P = 2.0= A. 11.94" La+a G •t D 2 : 4I r ( 4 4 .4.4 4 1 W Lra Lcko L )Ec.4 ,Its fit Sr C TlCAt. 11g- 2.o/2 + D.Lb = �. o I.LW,[ -t. - 1/�, o.1052 k1 = . /OS Z. 4 x I• 100/ 2, z �, 23/ k/ 4.( r� y . 023 14. Fz = 046 k er3 s- , 06I 4 Ft. , 093 2084 5.11 o,2311- S. D (L) U) ,QN a 4? - 4 .0/1 _ 4G 4= k . 23 )4. • = 23 m46. (2.10 /2.) t4-4/ T $ • 9 Srt- U) ?. A 4.e hub s s G.41,.7"1 CA-c- u- $ .r Afa Uhf 4.0¢ .. 14e4 = A. ¢3 k als I•J c, A. 241 •10 i Y lo.A$1 . ego M = SbS ± .. 2..(.ss Al) . 2'. '3 IL- _.._ 'k e .k o. ' RECEIVED CITY OF TUKWILA �.� __ .7 _1998 PERMIT CENTER BY 3 Tk- DATE 7- 9 8 PROJECT SHEET NO. OF CHKD. BY DATE JOB NO. 9170 /5.2 J. y � W Tbk /5,15 L CoGun+ -.'I3 9. S4 0.80 > .6 /4' row- R4.4j,c _ _Awe- /4:.20 co_C u i$ J 93 3 T Sx = 0,64-$ A• 0 5.3g k " ,� 8, 19 k- -s! . b FY _ 30 ks,: Q'a 15,94 G,s..2.40 .0014O3n4 re 33.k - S>zs re.r. = 6 4.9 g- atpkgtec A/ Fa rp s- 3.1 t 3 7.7 4 tom' � olx 6'.21( -6w/frip 17, 4-a *4-2 .3/ i' 27 dk 4 11, 3 00 1442 est, A. 8 r ` RECEIVED 1. 3dIT Y OF TUKW1LA JUL - 7 1998 PERMIT CENTER L� BRACING SECTION PROPERTIES PREPARED HY P. TTNGEY DATE 10MAY91 DRAWING NO. R-S REVISION NO. I DATE GAGE T in X in I x in4 Sx in3 rx in I y in4 Sy in3 'y in AREA 1n2 16 I .060 1 .4189 .0893 .1190 .62J4 .0379 .0456 .4066 .2297 14 I .075 I .4261 .1081 .1440 .6169 .0464 .0564 .4043 .2839 12 .105 .4405 .1418 .1890 .6041 .0621 .0767 .3999 .3885 10 .125 i .4551 .1706 .2275 .5914 .0764 .0960 .3956 .4878 o° aZ z Oa < LL. CD < cn �z < ° O = az 2 10 9 8 7 6 5 4 3 1 0 f H= 1 1/2 x X t_ T x B= 1 1/4 20 30 40 50 60 LENGTH IN INCHES 70 80 3.3 4.6 0.6 S fl _z .31 a0. .98 Wes. O .65 acn .32 S CEIVEKD�_t�N .66 Nz 3 3EN R 1 1 I 1 1 J 1 1 1 1 I t 1 1 1 1 1 1 1 1 1 1 9 7 5 O_v���� 1 I 1 1 1 1 - �`:01Ga I I "'� 14 • r t I I i 4 G a I��n�� \� 1 1 ���� ►n►RR �� 2 RM • 1 I � �-a• 1 I I 1 1 1 20 30 40 50 60 LENGTH IN INCHES 70 80 3.3 4.6 0.6 S fl _z .31 a0. .98 Wes. O .65 acn .32 S CEIVEKD�_t�N .66 Nz 3 3EN R EMT Ar BEAM SECTION PROPERTIES PREPARED BY P. s. Tingey DRAWING NO. R -1 DATE 14 SEP.'93 REVISION NO. DATE gy MODEL 1' in H in D in IX in4 SX in3 rX in I in4 Sy in3 ry in AREA in2 L8020 .075 2 .75 .2928 .274 .716 .6033 .4133 1.031 .5718 LB030 .075 3 .75 .7604 .4659 1.026 .8786 .6054 1.103 .7218 L8035 .075 3.5 .75 1.1854 .6313 1.223 .9475 .6712 1.093 .7922 LBC30 .075 3 .75 1.3689 .8817 .184 .9403 .6099 .9820 .975 LBC35 .075 3.5 .75 1.951 1.0473 1.363 .9705 .6159 .9614 1.050 LBC40 .075 4 1.5 2.6631 1.2769 1.538 1.105 .7096 .9921 1.125 LBC45 .075 4.5 1.5 3.5073 1.5033 1.709 1.2449 .8025 1.018 1.200 LBC50 .075 5 1.5 4.6437 1.7655 1.908 1.3902 .9029 1.044 1.275 LBC55 .075 5.5 1.5 5.7951 2.0453 2.071 1.5269 .9975 1.238 1.350 LBC55A .105 5.5 1.5 7.7919 2.7571 2.038 2.0719 1.3498 1.051 1.876 LBC60A .105 6 1.5 9.587 3.1421 2.192 2.1979 1.4517 1.049 1.995 LBF356 .060 3.5 1.5 1.2039 .6277 1.274 .7576 .5097 1.011 .7414 L8F354 .075 3.5 1.5 1.4739 .7699 1.267 .9284 .6242 1.006 .9181 L8F404 .075 4 1.5 2.0512 .9481 1.437 1.0635 .7190 1.035 .9931 LBF454 .075 4.5 1.5 2.7526 1.141 1.605 1.1984 .8143 1.059 1.0681 L8F453 .090 4.5 1.5 3.2119 1.333 1.598 1.3985 .9497 1.054 1.2578 RECEIVED CITY OF TUKWILA JUL - 7 1998 PERMIT CENTER eve 1 ' ? -94- • 5771404V, 3- P,74 LMT 4L4cx‘-r momei•IT CA-PAC Ty P1 /r1 frreP is C IOlo 1,4 /7)9 F : 44 kk' COLiJ/•n,+,1 inkrtr 2 )44. 11 ASTM A- 5 7o CPA 50 147M Pim Dimmc -ice C II /3Z PiM AMEN , Tf D=l4 • o. o9 2g I us 1 N & 141-+ R = " 4 f rte. F,rJ MAIL-14 AND us•rNtr ! Pp 1.0 F,,. 1 C401%41,4 W Anrin Mt P F s •O9Zgl x0.4x44.,o 6 ___ 71.0(s 156 c.44. Ora LM t5 AR LEI 20 (14.075 b) (11/32) „o, SA bs = 1.68k 4 (f Comp. 864.4 C b) LM 3o (t : O. /L2 S. ”) CrIWT (6N n, :61/32.) 0.Ib$ <65° 2,3c- P, : J, f ;14- _ X34, k A*40 P z 0.01 G k Ado )-!q I.63 4:75. D.Sbx 2.75+ .o9l xp.7S= /o,Ig 36" MA )0.18x 4/3 = 13.S7 k N jFFir-40k 42 Ice,: oil. 4S 1Ls; dip aa•I k F,4, S S k").' 611 14-i ) r� s CII/3L ) (o.o7s) x 'SS = I.4Z1` 1.41 3 47 t; (11 /3z) �D,105) (5 = 1, t.:DA-Prho C. S Arc L,ti 3o x1.42 /;.4,3 J (13. k" N j 7 ,I• PERMIT CENTER 1.61 1: ah Ow zo 46 4S l‘ z) Lnl 3o C efa -'l 4 s /.,5.} CD147724t. 4 91k RECEIVED CITY C F TUKWILA JUL 7 1998 "�° COLUMN SECTION PROPERTIES PREPARED BY P.s. Ting ey, DRAWING NO. R -2 DATE 16 JAN.'92 REVISION NO. DATE BY A 15APR'93 PST MODEL t in H in 8 in X in Ix in4 Sx in3 rX in Iy in4 Sy in3 ry in AREA in2 LM 15 .075 3 1.625 .689 .582 .388 1.156 .205 .219 .686 .411 LM 20 .075 3 3 1.435 1.023 .682 1.263 .872 .557 1.165 .618 LM30 .105 3 3 1.45 1.373 .915 1.249 1.164 .752 1.15 .859 LM20/15 '°7175 3 4.625 2.607 1.78 1.187 1.231 2.577 .988 1.481 1.143 LM20 /20 '07 75 3 6 2.714 2.222 1.481 1.268 4.701 1.431 1.84.5 1.349 LM30/15 '1%5 3 4.625 2.789 2.126 1.417 1.23 3.052 1.094 1.473 1.384 LM30 /20'10 75 3 6 2.951 2.568 1.712 1.262 5.45 1.788 1.838 1.590 LM30/30 '10 Q5 3 6 2.707 2.98 1.986 1.256 6.387 1.94 1.839 1.875 J PRAY COLUMN PUNCHED B .87 5 Y 3 13 .67 x .75 x BACK -UP COLUMN UNPUNCHED 1 x B Y Y LM LM / 6 x 1/7 July 17, 1998 City of Tukwila John W Rants, Mayor Department of Community Development Steve Lancaster, Director Northern Steel 22257 West Valley Hwy Kent WA 98032 Re: Permit Number D98 -0242 Spider Staging - 365 Upland Drive Dear Contractor, Please place these documents with the above referenced permit. We failed to give them to you when the permit was issued. Thank you, Tammy Frederick Permit Technician 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 PLA�N� EVIEW /�TIN��LIP ACTIVITY NUMBER: D98 -0242 DATE: 7 -7 -98 PROJECT NAME: SPIDER STAGING XX Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision After Permit Is Issued DEPARTMENTS: 5P Division Public WorkY n Fire Prevention 01, Sfruct ral I l n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete n Incomplete n Comments: DUE DATE: 7 -9 -98 Not Applicable TUES /THURS ROUTING: Please Route n No further Review Required Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) n REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 8 -6 -98 Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved n Approved with Conditions Not Approved (attach comments) n REVIEWERS INITIALS. DATE. \PR- ROUTE.DOC 6/98 City of Tukwila Fire Department Fire Department Review Control # DqS _oz2-. John W Rants, Mayor Thomas P. Keefe, Fire Chief • Re: Rack at 3 (pqj Dear Sir: line attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Storage may not be closer than 36 inches in all directions to ceiling - hung "Space or Unit". heaters. (UFC 1109.2) Storage may not be closer than 18 inches below sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) 2. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) 3. Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA, 231C, 3 -2.3) 4. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the • Building Code requirements for accessibility. (UFC 1204.1) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 John W Rants, Mayor Thomas P. Keefe, Fire Chief 5. Depending on the classification of the commodity being stored and the size of the storage area, smoke vents and curtain boards may be required by Table 81 -A of the Uniform Fire Code. Contact the'Tukwila Fire Prevention Bureau for further information. 6. Depending on the classification of the commodity being stored and the storage height, in -rack sprinklers may be required per N.F.. P.A. 231C. Contact the Tukwila Fire Prevention Bureau for further information. 7. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. 8. High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special - hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not .imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 3 Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 5754439 • DEPARTMENT.01; LABOR AND INDUSTRIES I:625.0524M (NI971 1:(25.12-1)1)11 tSit)7 ••••• • • • • • • • REGISTERED AS PROVIDED BY LAW AS CONST CONT .GENERAL # EXP. DATE CCO1.. '1\TORTHSCO24DT 09/01/1998 EFFECTIVE: DATE 103/30/1998 NORTHERN STEEL COMPANY 22257 W VALLEY HWY KENT WA 98032 Duacli And Disvlay Certirkatc REGISTERED AS PROVIDED BY LAW ASI CONST CONT GENERAL REGIST. # EXP. DATE CCO1 NORTHSCO24DT 09/01/1998. EFFECTIVE DATE 03/30/1998 NORTHERN STEEL COMPANY 22257 W VALLEY HWY. • KENT WA 98032 n:uurt Ismied by DEPARTMENT OF LABOR AND INDUSTRIES Please Remove Anc.1 Sign Identification Card Before PIacinzIn Bill Co Id •- v ••• V *mow s ''' : ` 0 0 r I GIRAY/NC NO SpiderStage OA r �a , ? - tP 6-29 -98 f L SPIDER STAGING TULWILLA, WA, NOTE: THIS DRAWING (OR PRINT) IS THE PROPERTY OF OF NORTHERN STEEL, Inc. KENT - WASHINGTON USA, AND SHAL L NOT BE TRACED, PHOTOGRAPHED, PHOTOSTATED OR REPRODUCED IN ANY MANNER NOR USED FOR ANY PURPOSE WHATSOEVER EXCEPT BY WRITTEN PERMISSION OF NORTHERN STEEL, Inc. ROM ROI MN MN MA OM ROA INN WS EOM IRSHIL UI tO>t Ill on In 44I0lf11M1 ORTHERN STEEL, MC K4AOL/NG SPEC/A' 22257 WEST VALLEY HIGHWAY KENT, WASHINGTON 98032 (206) 575 -1671 FA2 : (206) 575 -8506 1(800) 582 -1086 OC COPYRIGHT 1998 w RCA 340JA.'CT 444- -1746c "? C. FERGUSON r1 r U eD C) C_) CD LM20 F' 7 AS NOTED LM30 Dq8-02/01-2 Q CDnfigurntion 375 R 11/ 14 COLUMN STRUT 4 7 A F001 PLATE 8' -0`,9 u 10 0' OR 12' -0' B; figuration 375 R CJ G C C) C) §3 l ` I F 1/8" LM20 U N FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS 3'-8" BRACKET ASSEMBLY AS NOTED 075 THK `LM30 i 0 LBF 404 � C }Configuration STRUCTURAL NOTES 1. RACKS ARE MANUFACTURED BY LODI METAL TECH (LMT) OF LODI, CA 2 MINIMUM YIELD (Fy) ANT ULTIMATE (Fu) STEEL STRENGHTS SHALL BE AS FOLLOWS A) BEAMS AND COLUMNS Fy = 50ksi Fu = 65 ksi B) BRACING STRUTS Fy = 45 ksi Fu = 55 ksi C) BASE PLATES Fy = 36 ksi Fu = 58 ksi 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE 2,000 LBS 4. CONCRETE SLAB IS GIVEN AS 5 1/2" THICK WITH fc' = 2500pss 5. ALLOW. SOIL BEARING IS GIVEN AS 1500 psf FOR GRAVITr LOADS. 6- TIE —DOWN ANCHORS SHALL BE HILTI KWIK BOLTS OR EQUIV. USE 2 -1/2 "0 ,0, 4 1/2" ANCHORS WITH 3" EMBEDMENT PER BASE PLATE. SPECIAL INSPECTION IS NOT REQUIRED 7 POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA DEPICTING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION FIRE PROTECTION NOTES 1. Spinkler density is .39 gpm over 5,600 sa, ft. 2, Head temperature is set at 165 degree. 3. Type of stored product Aluminum and steel conponents. Top of stored product is 22'. No flammable liquids cored in warehouse. EALTING NOTES Exterior doors are .3' swim type with dead bolt and lockig knob that requires no special knowledge to oleraie. EXPIRES 7 /14/00 CITY OF TUKWILA. APPROVED JUL 0 9 1993 nS Ni) x• • I t4 RECEIVED CITY Of 7 JUL - 7 1998 PERMIT CENTER