Permit D98-0243 - BOEING #21-01 - OFFICE
D98 -0243 3417 So. 120th Pl. Boeing #21 -01 City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 102304 -9069 Address: 3417 S 120 PL Suite No: Location: Category: AMFG Type: DEVPERM Zoning: MIC /L Permit No: Status: Issued: Expires: Const Type: Occupancy: Gas /Elec.: UBC: Units: 001 Fire Protection: Setbacks: North: .0 South: .0 East: .0 West: Water: 125 Sewer: VAL VUE Wetlands: Slopes: Y Streams: Contractor License No: BOEINC*294ML OCCUPANT OWNER CONTRACTOR CONTACT BOEING #21 -01 3417 S 120 PL, TUKWILA WA 98188 THE BOEING COMPANY PO BOX 3707 M/S 1F -09, SEATTLE WA BOEING COMPANY PO BOX 3707, M/S IF -09, SEATTLE, WA 98124 GARY TALLER PO BOX 3707 M/S 46 -87, SEATTLE WA 98124 k*************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: PROVIDE 16'0" W X 17'0" L OFFICE WITH 9'0" CAPPED CEILING. PROVIDE DOOR, FRAME AND HARDWARE. k********************************************•******* * * * * * ** * ** * ** * * *** * *** * * * * * **** Construction Valuation: $ 2,300.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N k*************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 141.86 k********************************** * * * * * * *4c.* * * * * * * * *** * * * * * * * * ** D98 -0243 ISSUED 07/20/1998 01/16/1999 Not in table. 1997 SPRINKLERS /AFA .0 Phone: 206 - 544 -2975 End Time: Fill.: Permit Center Authorized Signature: * * * * * * * * * * * * * * ** Date: " 2.0-- I hereby certify that I have read and exa1lined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of wor am authorized to sign for and obtain this development permit Signature: Print Name: Date: 7- �o-'/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 3417 S 120 PL Permit No: D98 -0243 Suite: Tenant: Status: ISSUED Type: DEVPERM Applied: ied: 07/ 07/1998 Parcel #: 102304-9069 Issued: 07/20/1998 4, kk•4*: k; 4• k•*• k• kk• kk*• k*• k*k•. 4; H•*• 4• kkk• k; k• k• k. k• k• k• k• 4• k• 4• k• k*, 4* •k.4 *•k *•k*.44•k*•kk•k•k•k•k *k• 4•k•*•k•kk:4•*•kk•4k•k•k Permit Condition_.: 1. No changes, will be made to the plans. unles • approved by the Architect or Engineer and th.e.Tuk:a,il;a Building Divis•ion. 2. Ai 1 mechanical wor ha 1 1 be un.t er- :se Grate permit issued by the City of Tuicwi la:.'k. Provide mechanical ''.vent•.i.lation to the new office ea.:i =h a cordance: with,the Washington 'State Ventilation ;and 'Indoor, Ai.r.•, Oual ity..Code, fSec.:tiorf,,304 Table 3 -4. Installation of .aid vSten shall b-p a. reouirerent of final 1r1spect'iori aoorova1 . 3 All permits. inspection iorr records.' and approved-,plans Shall be avai lab,le at - the:.,job site prior to the stmt struct;ion. These documents are to• be ma intained and.•ava:i':1- 3L le until final inspection approval is granted. 4. All . on trut -t i on to be done in conformance with approved plant and-requirements1 and-requirements of tti,e.Unitorm Building r.nde Edition. a.. amended, Uniturrn Mechanical Code (19' 4 Ed1ti.on and. Washin +ton 'state EnerQv.Cude 0994 Edition) . 5. PartitiLn walls attached to ceiling •grici:must be laterr l.ly bracced it over eight (te) teet in,.. length, 6. Validity of Permit.. The issuance uance. of as permit or approval o plan., sutcitication.. and conrputat,icns shall not be con - strued to be a permit for, or. an' appro'v'al of, any violation of any of the• proviSions of the bu.i.ldina code or ot, ar,v .,,. other or"dinante of the urisdictiof: .No permit presuming; to' 00 :authority to violate or cancel the provisions.'-of th:i`s code sha i,1 be valid. GIT ` Q TI'f,�111LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 JOB 7152.71b-oo Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: // BLDG . ' t.J OI BOEING l Value Construction: I z, 5ca co Site Address: City State /Zip: 3 �►7 S. /�o , Tax Parcel Number: ro_ log 301-1 - 9067 Property Owner: THE BOEING COMPANY Phone: Street Address:p.o. BOX 3707 M/S 46 -87 SEATTLEi;y t 71,4Fax #: Contact Person: GARY TALLER /6T,r' L Li P : g e-44 -2975 itek,.6,554 /E6 Street Address: Cit�yy St to /Zip: P.O. BOX 3707 MIS 46 -87 SEATTLE, WA 98i2'+ Fax #: 206- 544 -2854 0C. \tel Phone: Street Address: City State /Zip: Fax it: Architect: G. K;11 cr Phone: .206- Gs-S- zLil86 Street Address: City State /Zip: Fax ft: Engineer: Phone: Street Address: City State /Zip: Fax #: Description of work to be done: ?ROvWWE l(o'•o "W x /7'.o "D oFFicr✓ WITH q..0' 1-1 e-AePEZ c.Erl -1g . 1"12- oUlbL Dc—, ►!.1 -'t6 4t4D NAIL') wrip.E. . Existing use: ❑ Retail Restaurant ❑ Church Llf Manufacturing ❑ School /College /University Cl Multi- family ,❑y Warehouse ❑Hospital ❑ Motel /Hotel G Office ❑ Other Proposed use: ❑ Retail El Restaurant ❑ Church L/ Manufacturing ❑ School /College /University ❑ Multi - family ❑ Warehouse CI Hospital ❑ Motel /Hotel f3rOffice ❑ Other Will there be a change of use? ❑ yes 'no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 'no Existing fire protection features: /sprinklers V automatic fire alarm ❑ none ❑ other (specify) t0 Building Square Feet: y &,0 AI existing Area of Construction: (sq. ft.) 3Qt -, in Will there be storage of flammable /combustible hazardous material In the building? ❑ yes o' no Attach list•of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS;SITE/CIVIL;PLAN'REVIEW'OF THE+FOLLOWING:'` (Additional reviews may be determined :by the'Public Works Department):' .':. ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Flood Control Zone ❑ Land Altering 0 Cut cubic yds. Cl Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt It: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Hauling 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale application accepted: C'rl'ERMIT.DOC 7/9/96 Date application explres: /-7-r9' Appllcat aken by: (Initials) ;L :C.OIVIMERCIAL/MULTI=F . L.Y.TENANT IMPROVEMENT /AL ATION.:PERMIT.APPLICATIONS • MUST.BE SUBMITTED WITH-.THE.rou.owING: • • AI.;CDRAININGS'TO. BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN i' BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description • . _ • ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale . 2 a. *Property lines, dimensions, setbacks, names of adjae"ht roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas • 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non- Residential Energy Code Date shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizingthe agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT ! HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A UTHOR! ^,- . Signature: [M - ,_ � Date: 7, 7.. ?$ Print name: GARY TAL R Phone:206 -544 -2975 Fax 11:206-5411--28511. Address P -n- BOX 3707 M/S 46 -87 City /State /Zip SEATTLE, WA 98124 CTPERMIT.DOC 7/9/96 City of Tukwila Fire Department John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Proj ect Name S)Ni)e.'■ NrNb k Thomas P. Keefe, Fire Chief Permit No. Dcli3-- 624-2) Address 3A S 9L1 Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM C:-1:24kM) Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 ^++;.*^+kx*4-+aA*):+*IkA4.+^*“*1-5*k+7‘+1%4+^*A'W**A*��*.**++ CITY OF Tu|NILA. NA TRANSMIT h*+++“ *.A+ *^*^*++A a*a+***+**++++aa*^* TRANSMIT 'Number: R9700796 Amount: � � 4.:!;0 07/20!98 10:03 Pavment Method: CASH Notation: BOEING init: TKF ----_-_--..—'--_-_�-_-------^---.---_----`�'-_,` • Permit No: D98-0243 Tyoe: D[VPERM ,DEVELOPMENT P[RMIT Parcel No: 102304-9069 � Site Address: S43,7 S 120 PL ' Total Fees: ` 141-88 \ This Payment ` 4,5O Total ALL pmts: • , '`�141.86 ' Oalancet ^OO *+ / �« AA ^++ +A 4*+ ^*A +*A A++ *++o +ha a+*+^+�vA k^**++**+�+*A***�a+++a*+ • Account Code Deycript1on Amount�� 000/386.904 STATE BUILDING SURCHARGE ' 3814 07/20 9717 TOTAL � '_^ '-.. ' 4°50 ,+kk++*-A+++**+*+**A+*+**+A+*+A++*+**+*A+*+*A++*+++**++4*++4+4**+ -ITY OF TUK ILA. NA TRANSMIT' ,*+*+A+*+*+*A*A+*k***++*+++++a+»+*f++*kA**k***A*k*+++A*****++** TrANSMIT Number: R9700793 Amount: 137~36 O7/07/98 14:59 Pavmant Method: CASH Notation: THE BOEING CONPA Jnit: 8LH Pormit No: D98-0243 Type: DEVPERM DEVELOPMENT PERMIT' Parcel No: 102304-9069 Site Address: 3417 S 120 PL Total Fees': : 127,36: This Payment 137.36 Total ALL Pmts: ' 137.36 " Ua]ance: ^Aa^*Aa+A*+^**+++****I'+AA-*+*+�+�*+*^+***�+^*�+++A*+�*** Account Code De°criotion � ��� `�� `Aount 000/322.100 BUILDING — NONRES 0O0/345.830 PLAN CHECK - NONR[S ' ..07/87 9717 TOTAL • •".", ,. - w;:S. •;..'' {'!'`x°tx a �� �t: "'s^::"i r' v<= R n � ::[^; F3 ^+: t�� ;t •: .. - r;J: - - z r, „. - INSPECTION RECOD Retain a copy with pi, tit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 PERMIT NO. —(206)-43 670 Project: e9 ! _Of Type of inspeion z".-- Address 7 Date called: Specia Instructions: �J- /2.P•_ Date wanted: Crl Requester: Phytne No.: 2-U4 -c/ / — ; /e/L j4., Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector Da7 if g $4'+'r `EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: ;. r.Y'7,7'7r. 'M==" "',," "- ;o-" :117. rv':M7._ 1,giu:i'i .W?.a'�"•a CyA;;Vr`rq.W- c�..'R+,,. ,. err,:• 1, m�....: H• r.^. ta,,.: r' h' y;.:. r�.^ tur '- .y,'..�.s:Y :ti,:ixr.^r.:•...�p INSPECTION NO. INSPECTION REC( `zD Retain a copy with Pt.—,nit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 1*- 02/0 PERMIT NO. (206) 431 -3670 Project: /L 0 �4/ 0/_O/ Type of inspection: r� 3. 141& (' Address:"— 3/ _ Jai �zc� v Date called: g /Z4/s,> Specialliinstruc ions: U �" jj►Lfli) �i �� Date wanted: Vzg �1 �' p.m. LQ Requester: Phone .• Ph Noa4, -9q1 -37V z- Approved per applicable codes. COMMENTS: iy,K. Corrections required prior to approval. 5 , Inspector: Add $42.00 REINSPECTION F Y' REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: Receipt No.: Date: uY({aTvxti•:"7:Sw ... N+' t4ii lR:IigFlifiiiy`.�/i5T'�or. ""'� . rte_" "!v."'+.1.1 •_ . . INSPE TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 INSPECTION RECP''D Retain a copy with 1L.'nit Project: & n r7/— 4( Type of inspection: 6rrifri-1I Address - i j 26 f� Date called: Special instructions: b1)—€ a Date wanted: T' !� 4`� a.mi p.m. Requester:. Phone No.: L.9 5 S , 2_6 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7/ 064)8 cfi,--Avtiz-da Inspector: Date:��� $42.00. REINSPECTION 'EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: ?€rn4t (wrd C,u PLAN REVIEW/ROUTIN E SLIP ACTIVITY NUMBER: D98 -0243 DATE: 7 -7 -98 PROJECT NAME: BOEING //21 -01 XX Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision After Permit Is Issued DEPARTMENTS: D ivision Ei 1-61-618 F3tis` '/A s Fire revention PlariDivision Structural n Permit oordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 7 -9 -98 Complete n Comments: Incomplete Not Applicable TUES /THURS ROUTING: Please Route No further Review Required Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) n REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 8 -6 -98 Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved n Approved with Conditions 0 Not Approved (attach comments) n REVIEWERS INITIALS: DATE: \PR•ROUTE.DOC 6/98 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Fire Department Review . Control # 2618-624,3 Re: T.I. at .l�.P�4 kLei *d --01 Dear Sir: �' i2a ?1 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area.. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1-6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with ,a sign stating, "Fire Extinguisher ", with an. arrow pointing to.the unit. (NFPA 10, 1-6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly.:: inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the. service. (NFPA 10, 4 -3, 4 -4 and 4-4.3) Every six years dry chemical and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief halon type fire extinguishers shall be emptied and ' subjected to the applicable fecharge procedures. (NFPA 10,4-4.1) If the required monthly and yearly inspections of the fire extinguishers) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel.. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area. or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the .direction 'of egress. (UBC 1013 1) When two or more exits from a story are required and when two or "more exits from a room or an area are Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 3 John W. Rants, Mayor Thomas P. Keefe, Fire Chief required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Internally illuminated exit signs shall have both bulbs working at all times.. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1•.3.2.1) 7. Maintain hose station coverage per City Ordinance, #1742 and N.F.P.A. 14. Addition /relocation of walls or . partitions may require relocating and /or adding hose stations. 8. An approved hose station requires plans review.. (Plans must be submitted to the Fire Marshal for .approval prior to installation.) (City Ordinance #1742) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 4 John W. Rants, Mayor Thomas P. Keefe, Fire Chief 9. All new sprinkler systems and all modifications to existing sprinkler systems shall lave fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau.' No work shall commence until a fire department permit has been obtained. (City. Ordinance #1742) (UPC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required .fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire. resistive Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Far (206) 575-4439 City of Tukwila Fire Department Page number 5 John W. Rants, Mayor Thomas P. Keefe, Fire Chief requirements based on type of construction, draft stop partitions and roof coverings shall be-maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted'on the building and shall be plainly visible and legible. from the street. Numbers shall contrast with their background. (UFC. 901.4.4) In order to. provide you with the fastest police and fire protection under emergency conditions, please . post your suite, room or .apartment number in a conspicuous place near the main -entry door. Numbers shall contrast with their background. .(UFC 901.4.4) Contact The Tukwila Fire Prevention'Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only. special fire permits may be necessary depending on- "detailed description of intended use. Any overlooked hazardous condition and /or violation:of the 'adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 6 Yours truly, John W. Rants, Mayor The Tukwila Fire Prevention Bureau cc: TFD file ncd Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 e Fax (206) 575-4439 Page 2 Facilities Focals 1- 9604- DBW98052 May 14, 1998 1- 9604- DBW98052 To: Distribution List Subject: 1998 Washington State Contractor's License for The Boeing Company Enclosed is a copy of the Washington State Contractor's License for 1998. This license expires on January 1, 1999. Please contact me if you have any questions. 91/4- D. B. eigelt 1 -9604, 1F-09 ,206) 655 -4535 Enclosure E Detach And Display Certificate DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ",REGISTRATION NUMBER CC01; •,".- BOE1NTC *94ML 01/01/.1999: EFFECTIVE ;DATE: 07/13/1971 BOEING COMPANY, THE PO BOX 3707 MAIL STOP IF -09 SEATTLE WA 98124 -2207 F625"0524)po Is/97) Detach And Display CerlitiL.IIL C RECEIVED ITY OF TUKWILA MAY 1 5 1998 PERMIT CENTER VICINITY MAP I AREA MAP GENERAL NOTES DRAWING INDEX % - KING cow', FROM DOWNTOWN SEATTLE %:D❑ CR R 'ATE �/ L 14_01 0 I 5 BLDG. 21-01 ADDRESS: 3417 SO. 120TH PLACE TUKWILLA, WA. (EAST MARGINAL WAY CORPORATE PARK) E BE SITE ODURING OF RUCTION. DO REVIEWED PROCEED STAMPED WITH CONSTRUCTION UWIT MUST WITHOUT ABOVT. MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO GARY TALLER AT BUILDING 9 -51.2 COLUMN N /1, AFTER COMPLETION OF THIS CONSTRUCTION. SHEET N0. DF .WING 'r:' 0. SHEET TITLE REVISION N0. DATE AO 21 -01 -A0 TITLE SHEET SUBTITLE S�• TITLE SHEET •�r�'�' 07.08.98 1Fl01 21 O1 1A0? EXITING PLAN B 07.08.98 1A11 21- 01 -1A11 FLOOR PLAN D 07.08.98 A508 21- 01 -A509 SECTIONS AND DETAILS ORIG 07.08.98 GMM ( -1-0Ay 07.08.98 - APPROVED BY DEPT. DATE J BDRKS 09.13.95 j. * \ 900 t. Nµ�fUM ' \\ A1 I T PROJECT CHECKED 4 'S''' 'S''' ,� \\ _ ^ � \� J PROJECT CHECKLIST APPROVED JOB NO. 157080 21 -02 , - - -� 21 -01 CHECK BOX ® THESE DRAWINGS CONFORM TO THE 1997 U.B.C., U.F.C., U.P.C., AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. E] ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. El BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS ® 2. TENANT IMPROVEMENT (NON- STRUCTURAL): ®4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS CI 3. MECHANICAL, 4 COMPLETE SETS. 111 4. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS. 63 BRIEF PROJECT NARRATIVE PROVIDE AN OFFICE AREA 16 -0" WIDE x 17' -0 LONG WITH A 9' 0" HIGH CAPPED CEILING COMPLETE. PROVIDE DOOR, FRAME AND HARDWARE COMPLETE. U 9 0` / , q , a � T � �i !!� F � ��� %' / 99 �y IXIT I — \ I V j 21-0.3 I I I 'I I 'I O ` DWG No. 21 -01 -Al .- E .in p;1 C15B ss ozeow LOT / • G s vg pENG ACCESS • v v / j Q _ \ \ I I I \ I I I ` CODE SUMMARY ■ \ \ // A EXIT LAND USE C( DE M-HP CODE REFER( 1994 U.B.C. U.F.. ., U.P.C., AND THE WAC ADAPTED OR AMENDED BY LOCAL ORDINANCES COMPLIANCE WITH CITY OF TUKWILA ZONING 1 (FACTORY) NO CHANGED CONSTRUE IO1 ` TYPE V B -1 SPRINKLER LOCATION ON PROPERTY SEPARATION 90 FEET (3- SIDES) FLOOR AREA ;ACTUAL) BUILDING FOOTPRINT (98,000 SF) ABATE PERMIT SEPARATE RE - ED FOR: 51 ' CH FOR: P -: ELECTRICAL ❑ PLUMBING qS PIPING CITY OF TUKWILA BUILDING DIVISION \ ` 21 -05 ` `` \ 157—, IXR ' I , 11 i / ' illik, � I Jr 0 599 EAST MARGINAL WAY TUKWILA \ / 57 900 I I �- c I III I II \ � I„ - �� I : I I III ! ii �\ I BUILDING HIT - :HT: 26 1/2" FLOOR TO PLATE STORIES: 1 OCCUPANT L( AD: NO CHANGE FIRE PROTEC 'ONS FULLY AUTOMATIC, WET PIPE SEISMIC ZONE 3 FIRE ZONE 3 PARKING PRG TIDED 73 PARKING RE i'!IRED 725 CITY OF TUK4H CA FILE COPY FROM KENT &AUBU - \ I understand that the Plan Check a;.prc:_L^ a:s s U $QLGI rA and omlastons and apprvd of lens does not authain V violation of an P y adopted code or canna Aaoetpt of contractors copy of emoted per (� , /� a � CORPORATE PARK 99 - --, \ ' \ N NO SCALE EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE- TACOMA AIRPORT I PROJECT\\ SITE N s c , ) it: I 8 NO SCALE DEVELOPMENTAL CENTER Date 7_gv /5 r_ ` / , LL Permit No. ,e4 APPROVED JUL 1 s 199 V NO L D •,. RECEIVED FL Clr:: 1.7,FON CITY OF TUKWILA JUT. -71991 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN EDDIE P. DUARTE DATE - 12.13.91 SUBTITLE S�• TITLE SHEET •�r�'�' v I C./ We. I✓ CURRENT REVISION SYMBOL 782718 -00 — SHEET DATE 07.08.98 - I IR TEST VAN Jj' -00 GMM 02.11.98 CHECKED J.BURKS 09.13.95 - ENCLOSE NW CORNER ADL J #782718 -00 GMM ( -1-0Ay 07.08.98 APPROVED BY DEPT. DATE J BDRKS 09.13.95 TITLE BUILDING ®0 ' 7' ARCHITECTURAL MASTER D.C. A1 CHECKED APPROVED JOB NO. 157080 COMP NO. APPROVED DWG No. 21 -01 -Al os roJE 1 NG ]FORMATO SACH & DEFESE SYSTEMS IBUII _ORO 2 d -0S ENC_OSE NW CORNER AD_ (,4782718-00) BOEING DEVELOPMENTAL CENTER 3417 S. 120TH PLACE TUKWILA, WASHINGTON 98108 SYM A IR TEST VAN ENCLOSE NW CORNER ADL REVISION DB - oZ46 J #775108 -00 J4782718 -00 BY GMM GMM APPROVED DATE 02.11 98 07.08.98 SYM REVISION PLAN SCALE: 1 "= 30' -0" APPROVED DATE .0erizE4fAr ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED. BY DEPT. DATE DRAWN M.DITTMER CHECKED ENGINEER CHECKED APPROVED APPROVED DATE 04.10.93 SUBTITLE TITLE EXITING PLAN BUILDING 21 -01.1 ARCHITECTURAL MASTER, CCOL'A -L/1 -8 CITY OR T0KVALX APPROVEO JUL 1 6 1838 LEGEND: EXIT PATHWAY GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE BUILDING HAS BEEN CONDUCTED AND NO ASBESTOS CONTAINING MATERAL WAS WAS DISCOVERED WITHIN THIS BUILDING. CONSTRUCTION NOTES: RECEIVED CITY OF TUKWILA JUL 1998 PERMIT CENTER CURRENT REVISION 782718 -00 DWG NO. SMBOL SHEE 1AO1 JOB N0. 727680 -00 21 01 -1A01 DATE 02.11.98 COMP NO. D.C. -I SYM REVISION PM &PT PICK -UPS B WALL BEHIND AUTOCLAVE WALL BEHIND AUTOCLAVE (REVISION ENCLOSE NW CORNER ADL 11D2 J#901424 -15 Jf`901424 -19 J4901421 -19 J4782718 -00 BY APPROVED 71T 71T 71T GMM DATE 02.06.92 03.06.92 04.20.92 07.08.98 SY 1A11, A200 . WALL ANCHOR ' ABOVE 1A11 A200 J REVISION LL FLOOR PLAN SCALE: 1/8 "= 1' -0" APPROVED DATE ACCEPTABILITY THIS DESIGN AND /OR SPECIECATION IS APPROVED PPP.CVED BY DEPT. DATE oRAwN EDDIE P. DUARTE CHECKED N HECKED APPROVED ,PFROVED DA, SUDTITLF. 01.06.92 TD LE FLOOR PLAN BUILDING 21-0 ARCHITECTURAL MASTER COL D -C/ 1 -5 CONSTRUCTION NOTES: REMOVE EXISTING 5' -0" HIGH PARTITION COMPLETE. SEND TO SURPLUS. 2 'CONSTRUCT OFFICE COMPLETE. SEE SHEET A508. CITY US TUN IU RPPRQU'AD _E END: JUL 1 6 1998 GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE BUILDING HAS BEEN CONDUCTED AND NO ASBESTOS CONTAINING IAATERIAL WAS DISCOVERED WITHIN THIS BUILDING. INSTALL DOOR FRAME, DOOR AND HARDWARE COMPLETE INCLUDING UNICAN, CLOSER, SMOKE SEAL, HINGES, BUMPER, KICKPLATE AND DOOR BOTTOM (DOOR 11F1). 'PAINT ALL WALLS, CEILING, DOOR FRAME, DOOR AND TRIM WORK AT OFFICE (INTERIOR /EXTERIOR). MATCH EXISTING. FABRICATE AND INSTALL FOUR (4) CAUTION SIGNS (10 "W x 7 " H) AT ROOF OF ROOM-(SOUTH /EAST EDGE). CAUTION SIGNS TO READ: "NO ACCESS NO STORAGE ALLOWED" ©ALIGN FACE OF WALL WITH EXISTING FACE OF WALL. INSTALL CARPET SQUARES, BASE (BOTH SIDES OF WALL) AND A CARPET EDGE AT THE DOOR COMPLETE. CONTACT MARK KOWALSKI (425- 477 -3861) FOR CARPET SQUARES. 1A10 1A11 1Al2 1A13 IA14 I 1A15 KEY PLAN! SCAL A: NONE DWG NO D..C. 21 -01 -18.11 RECEIVED CITY OF TUKWILA ,1 I.iL "' ! 1998 PERMIT CENTER DATE 07.08.98 SYM REYSION BY APPROVED DATE WALL - SECTION (TYP) SCALE: 1 "= 1' -0" REVISION 1A11� A508 APPROVED DATE 6 1/4 (R -19) BATT INSULATION — CONTINUOUS PLYWOOD — 3 4" T &G UNDERLAYMENT FIRE RETARDANT ATTACH WITH 10 x 1 1/2" LONG SELF TAPPING SCREWS AT 6" O.C. AT EDGES AND 1' -0" O.C. IN FIELD IF PLYWOOD 8" x 16 GA CEE JOISTS AT 2' -0" O.C. ATTACH WITH #10 x 1 1/4" LONG SELF TAPPING SCREWS ALIGN WITH WALL STUDS — 1" x 6" WOOD TRIM -- CONTINUOUS 8" x 16 GA TD TRACK AT PERIMETER — CONTINUOUS ATTACH WITH #10 x 1 1/4" LC;NG SELF TAPPING SCREWS NOTE: FOR FRAMING T) EXISTING WALL AT WEST END SEE DETAIL / A TE A5D8 3 5/8" x 18 GA TLI f7L iCK — CONTINUOUS ATTACH WITH #10 x 1/4" LONG SELF TAPPING SCREWS 5/8" TYPE 'X' GYPSUM WALLBOARD ATTACH WITH #6 x 1 1/4" LONG DRYWALL SELF TAPPING SCREWS AT 6' 0.C. AT EDGES AND 1' -0" O.C. IN FIELD OF GYPSUM WALLBOARD 5/8" TYPE 'X' GYPSUM WALLBOARD BOTH SIDES ATTACH WITH #6 x i 1/4" LONG DRYWALL SELF TAPPING SCREWS AT 6' O.C. AT EDGES AND 1' -0" O.C. IN FIELD OF GYPSUM WALLBOARD 3 1/2" (R -11) BATT INSULATION — CONTINUOUS 3 5/8" x 18 GA CEE STUDS AT 2' -0" O.C. WITH STUD BRACING AT 5' -0" O.C. (CHANNEL — 1 1/2" x 16 GA AND CLIP — 1 1/2" x 1 1/2" x 16 GA x 3 3/8" LONG) ATTACH WITH #10 x 1/4" LONG SELF TAPPING SCREWS FRAME AROUND SUPPLY AND RETURN DUCTS SEE MECHANICAL DRAWINGS FOR LOCATION 4" RUBBER BASE — BOTH SIDES 3 5/8" x 18 GA TO TRACK — CONTINUOUS HILTI — HIT ANCHOR 1/4" DIAMETER x 1 1/4 LONG AT 2' -0" O.C. EXISTING CONCRETE SLAB WALL SECTION SCALE: 3 1' -0" DRAWN ACCEPTABILITY G.MILLER THIS DESIGN AND /OR C SPECIFICATION IS APPROVED 116-lo APPROVED BY DEPT. DATE G.MILLER DATE 07.08.98 CHECKED APPROVED APPROVED SUBTITLE TITLE SECTIONS AND DETAILS E!UILDIN+G 21 -01 r� ( A 1A11 A508 A508 LEGEND: ARCHITECTURAL MASTER COL. D.C. GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE BUILDING HAS BEEN CONDUCTED AND NO ASBESTOS CONTAINING MATERIAL WAS DISCOVERED WITHIN THIS BUILDING. CONSTRUCTION NOTES: .___ -- — 8" x 16 GA TO TRACK — CONTINUOUS j 2 x 2 x 16 CA x 6" LONG ANGLE CLIP (BRIDGE CLIP) (A- ) #12 -14 x 2" LONG SELF TAPPING SCREWS AT 2" O.C. TRACK TO EXISTING STUD) 8" x 16 GA CEE JOISTS AT 2' -0" O.C. 3) #10 -16 x 1 1/2" LONG SELF TAPPING SCREWS AT 2" O.C. (CLIP ANGLE TO JOIST) (3)#10-16 x 1 1/2" LONG SELF TAPPING SCREWS AT 2" O.C. (CLIP ANGLE TO TRACK) #10-16 x 1" LONG SELF TAPPING SCREWS (TRACK TO JOIST) TYPICAL AT TOP AND BOTTOM EXISTING WALL: 5/8" TYPE 'X' GYPSUM WALLBOARD BOTH SIDES OVER 6' x 18 GA METAL STUDS AT 2' -0" O.C. WITH 6" BATT INSULATION CITY OF TUKWILA APPROVED JUL 1619SD CLRRENI PEA ^SiO� SHEET A508 JOB N0. 782718 -00 DOS NO. 21- 01 —A508 REIVED CITY OCEF TUKWILA JUl. - 7 1D98 PERMIT CENTER DATE COMP NO.