Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D98-0260 - BON MARCHE - WOMEN'S DEPARTMENT
D98 -0260 500 Southcenter Mall ion Marche City of Tukwila t (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9086 Address: 500 SOUTHCENTER MALL Suite No: Location: Category: ARET Type: DEVPERM Zoning: TUC Const Type: II -N Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: .0 South: .0 Sewer: N/A Slopes: N Contractor License No: PUGETSB099PD OCCUPANT OWNER CONTRACTOR CONTACT Permit No: Status: Issued: Expires: D98 -0260 ISSUED 09/29/1998 03/28/1999 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERS /AFA East: .0 West: .0 Streams: BON MARCHE 500 SOUTHCENTER MALL, TUKWILA WA 98188 BON MARCHE Phone: (503) 579 -7083 C/0 FEDERATED DEPT STORES, 7 WEST SEVENTH ST, CINCINNATI OH 4520 PUGET SOUND BUILDERS Phone: 206 251 -1661 18852 72ND AVENUE SOUTH, KENT, WA 98032 JAY LIKNESS 18852 72 AV S, KENT WA 98032 *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REMODEL OF INTERIOR WOMEN'S WEAR SPACE. WOMEN'S LOUNGE MODIFIED. NEW CARPET INSTALLED. LIGHTING REVISED AT PERIMETER. **************************************************** * * * * * * * * * * * * * *' * * * * * * * * * * * * * * ** Construction Valuation: $ 65,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No: Size(in):: .00 Flood Control Zone: Hauling: Start Time: End Time: Land Altering: Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time: End Time: Sanitary Side Sewer: No:. Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 1,239.94 ********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *j ********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Phone: 425 -251 -1661 Private: Public: Permit Center Authorized Signature: Date: o...9 -1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. ,,I am authorized to sign for and obtain this development p 't. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 500 SOUTHCENTER MALL 'Permit No: D98-0260 Suite: Tenant: Status: ISSUED Type: DEVPERM Applied': 0713111998 Parcel #: 262304-9086 issued: 09/29/1998 kft**A**kk***OrAk*k***A*Ork.A***k**k*k*****kkAkk****k*****kkk******kkkkk******k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the jukwila Building Division. Electrical permits shall .be obta)ned-throuah the Washington State Division of Labor and Industries-andAll electrical work will be inspected by that agency (2486B30). 3. All permits. inspection .records, and approved plans shall be available at the Job site prior to the start of any-con- struction. These documents are to be maintained and avail- able until final inspection approval is aranted. 4. All construction to be done in conformance with approved . plans and requirements of the Uniform Building Code (199-7 Edition) as amended, Uniform Mechanical Code (1991 Edition), and WaShinaton State Energy Code (1997 Edition) ". 5. Validity of Permit, The issuance of a permit or approval of plans,, specifications, and computations shall not be con:- strued to be a permit for or an approval of, any viola,tion\ of .any of the provisions of the building code or of any other ordinance of the.jurisdiction, No permit presuminvto give authority to violate or cancel the provisions of 'this code sha11 be valid. CITY OF TUKWILA Permit Center "'" 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 ommere! 'enant Im_provemenl ter atio err11t 3li•cation Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Narne/Tenant: Bon Marche at Southcenter Mall Value of Constr ction: -� ,--26- CCO Site Address: City State /Zip: .;c :; Southcenter tn•,c,.rt_ Tij. wi 1 a 9818 Tax Parcel Number: 2@-2:__ --i7r<: Phone: 513 579 7382 Property Owner: Federated Department Stores, Inc. Street Address: City State /Zip: 7 West Seventh St. Cincinnati, OH 45202 Fax #: Phone: ; 425 251 1661 Contractor: Puget Sound Builders Street Address: City State /Zip: 18852 - 72nd Ave So. Kent, WA 98032 Fax #: 425 251 1658 Architect: William Polk Associates Phone: 206 622 8443 Street Address: City State /Zip: 1120 Post Alley Seattle, WA 98101 Fax #: • 206 622 8031 Phone: 425 820 1542 Engineer: Interface Engineering Street Address: City State /Zip: 12020 113th Ave NE Kirkland, WA 9803 Fax #: 425 820 1628 Contact Person: l� `� / �� f�i t°S/' (/2g,/) \/ P2 Street Address: t/ City State /Zip: ', s S Fax #: ,z -25/ --/65-k 2 ^ e • e , iti/Q %? 2— Description of work to be done: Remodel of interior women's wear space. Women's lounge modified. New carpet installed. Lighting revised at perimeter. Existing use: ® Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: a Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School/College/University ❑ Other Will there be a change of use? ❑ yes El no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes a no Existing fire protection features: %® sprinklers ® automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 26 5, 0 0 0 S F existing Area of Construction: (sq. ft.) 6, 000 S F Will there be storage of flammable /combustible hazardous material in the building? ❑ yes © no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: ❑ Land Altering 0 Cut cubic ydss.-.qq ❑ Sanitary Side Sewer If: t� ❑ Storm Drainage ❑ Street Use ❑ ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling Size(s): 0 Fill cubic yds. Sewer Main Extension Water Main Extension 0 Deduct Est. quantity: ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Applic; Lion taken by: (Initials) CTPERMIT.DOC 1/29/97 `PLEASE:SIGN :BACK OF APPLICATION.FOR L COMMERC/AVMULTPFAMILY.TENANT IMPROVpaENT. /ALTERATIgN PERMIT APpLICA.TIONS . MUST BE SUBMITTED .WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN r BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N //1 SUBMITTED ❑ ❑ Complete Legal Description El El Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). lJ Floor plan: show location of tenant space with proposed use of each room labeled fiOverall building floor plan witty adjacent tenant use; identify tenant space use and Location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ X❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". ❑ Vicinity Map showing location of site ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. Indicate proposed construction of tenant space or addition and watts being demolished ❑ ❑ Construction details Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGEN Signature: IL Print name: AMF,)/j`] 1,1J4X Address • at. i 1 i t�C"r CTPI_:RMIT.DOC 1/29/97 Date: r)/ 1 J;: s Prone. C� #: ,, � ,{ City /State /Zip i OA— Fax 114- fivacia *+*****�**+^*+***+***+++ra**a*a+**+.++*+*+*aA**a“^k**A*A*^+0.**.+ CITY OF TUKNILA, NA ` ' ' ' • TRANSMIT ***a*+***++**+k**+x*******+*a***a***«aa+**a*******+*******++***+ TRANSMIT Numiier: R9700839'Amount: ` 753.25:09/29/98 Payment Method: CHFCK Nntatjon: PUGET SOUND BiDR. Init: BLH Permit No: D98-026O Type: DEVPERN DEVELOPMENT 'PERMIT ` Parcel No: 262304-9086 Site Address: 500 SOU7HCENTEH MALL 'Total 1 �39 94 l Fees� This Payment 753.25 Total ALL Plot's: � 11239.94 ` '- Balance: ` �`� .00 ' +**0***^****^*****^a*+*a+a**++a*+***********a**+^+***«*a4******* Account Code Description � ��' � Amount 000/322.100 BUILDING, - NOHRES : ' ' �`` `748.75 000/386.904 STATE BUILDING SURCHARGE', ' 4.50 ' ` ` __'. . 6258 09/30'9717 . 753"25:���'� `` ' x+A*^+***A**A*++*+A+**+++**++A**+A+a*++�*+A*A+4*+A+4+++Ak«*a*^**� -ITY or TUKNILA. NA ' ' ` � , �� T R A@SMI1�! N.x*+**A*`***+*+A*A+AA A+++***A++*AA+**++*+++A++**1:^+*A+ hit* ^++****'` TRANSMIT Numher: R9700803 Amount: 486.69 O7/31/98 09:08 Pavment Method: CHECK Not�tion:�pU0ET SOUND 8U[L Trrit: BLH Permit No; D98-026O Type: DEVPEkM DEVELUPMENTPEKMIT Parcel No: 262304-9086 Site Address: 500 SOUTHCENTEH MALL 2 � . Total Fees: . 1, 39 .94� This Payment 486.69 Total ALL Pmts: '� `� 486.69'�'' Balance: `/53"25 �aA++^+^a*++*****++*++A+A**'AaA*«^+-fiA*+A+*a*1W***4*+*+a'A**i6***� ' ' Ack,ount Code Description �` ' '�. Amount 000/345,830 ` PLAN CHECK~.NONRES � ' '��' 486.69'`'' 4280 08/04 9717 TOTAL: ` 486"69 `.�.� • INSRIEC "ION REC( ) Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd #1QQ; Tukwila, WA 9818 1 ,,,-..,7:-• ,r ^,7•••-• ....n.,-. ! 'NV) "")A, PERMIT NO. (206)431 -3670 Project: s ,,A-/p hype pection• Adds 5 ` ` Date ca e : .71 ci CI S c 'n tructions: k � (3 �.(A j t; A `"' �O /0\11,Li .Date wanted: z C1 P.m. Reque ,zA „6"ss - Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe ro / Dat n $47.0+ REINSPECTION FEE REQUIRED. Prior to inspect on, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: . ,rn'A-ofFR.' ye.r,rrvlwrocx,. ;aq .4^! g.r.t op,79zgr::.tnzy?F" pp.., i.i`�'.`t"NVZ sF ((�`gy's.. a' 'W:,'n1:;..ra.yr„n.rT+. -, a.1` � .;L=ii Yt�� •rya /;}.. i% INSPEC NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 INSPECTION REr RD Retain a copy with, eermit Ms-021P0 PERMIT NO. (206).431 -3670 Project h l "av c x Type-ti -5 t do jj `� ��� Address: ov So1,(Gcc��(c.„, 1 k �p Date called: 0 [° Special instruction : 1 l C 0 c �>� /,. i f �c,f.° v f � a - , 2: 3° r ' ' (42 -) 2 5 (- 166 1 Date wanted: a.m. 16 (S 9 C p;mi Reque �t r: ,^ Phone No.: Q (�() 3 96.85q(3 e Approved per applicable codes. COMMENTS: ova Corrections required prior to approval. P1 $42.00 REINSPECTION " E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: Pne vacs IN ECTION NO. • _ I INSPECTION R RD Retain a copy wit .',,eermit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 PERMIT NO, (206) 431 -3670 Project: rV Zr I - rYt �rQ Type of inspection:f r( (M{ v.( ► t Addre : _ s c �,k Date called: t o/ .� Special instructions: 11`3 F Date wanted: /_ Requester: Li-2_ a f r one ` of c2 015/ _Rde: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector. Date: /O �3. 1--1 $42.00 REINSPECt16N , E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ;:. C City of Tukwila Fire Department John W Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Thomas P. Keefe, Fire Chief Permit No. . 92 - Project Name AO ■-1 A44 h Address -S C>3 0-7f fr■ Cr, /1/1,, 1/ Suite # Retain current inspection schedule Needs shift inspection -7( Approved without correction notice Approved with correction notice issued Sprinklers: ///// Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: 1,1,46 r/90 1-4/J1/ Authorized SignAure Date //- 3 FINALAPP.FRM 11111.011/ Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax 575-4439 FEv PLAN REVIEW /ROUT ACTIVITY NUMBER: D98 -0260 DATE: 7 -31 -98 PROJECT NAME: BON MARCIIE XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter Revision After Permit Is Issued DEPARTMENTS: u ildin Division S -Z `11 iKSl i /0/o Fire revention tructuraLN' Pla 'BSI g Division PL.)rfiit Cocirdirlor DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete n Incomplete DUE DATE: 8-4-98 Not Applicable n Comments: TUES /THURS ROUTING: Please Route n No further Review Required Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) n REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 9 -1 -98 Approved Approved with Conditions n Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved Approved with Conditions El Not Approved (attach comments) REVIEWERS INITIALS: DATE: \PR- ROUTE.DOC 6/98 City of Tukwila Fire Department Fire Department Review Control #D98 -0260 (510) John W. Rants, Mayor Re: The Bon - 500 Southcenter Mall Dear Sir: Thomas P. Keefe, Fire Chief August 12, 1998 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phones (206) S75-4404 • Fax (206) 5754439 r• City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1003.5) 3. Maintain sprinkler coverage per N.F.P.A. 13. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 3 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of . such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 4 Yours truly, 5 (o John W. Rants, Mayor The Tukwila Fire Prevention Bureau cc: TFD file ncd Thomas P. Keefe, Fire Chief Headquarters Station: 444Andover Park East • Tukwila, Washington 98188 • Phone (206) S75-4404 Far (206) 575 -4439 'REGISTERED AS PROVIDED BY LAW AS A: :. REGISTRATION NUMBER ..; ; .• ' ... EXPIRATION DATE. • ; ,.F.5F �'T •t. V E. D #T';E': 14.1 • 47.9.1. 18.8';5.2 D' AVE 5 KEN '• VA . 98032 SIGNATURE Mc'IT- OF LABOR AND INDUSTRIES �� 1 LMUUltT ',LMOOirr f WOMENS LOUNGE FITTI G ROOM SEFDEMBLI-T49N- IDWGS -- - SE€- DEMOLITION -DEMOLITION- MS_ I SAND FINISH DRAWINGS . AND FINISH DRAWINGS I3 19 (I) 2l 22 23 24 25 24' -0" r I 1 li 1- I'll -05, - r � r - � II ♦ err i Ir / I nh�/ I I �Irtll�, /0-,.• .'► '� �� ` �� + � � f /lil O % 41,0; i ce' r , . /i /� %t� II r I� I H I .. r - d � / � / �f � fora ;A � , 7 H S // i. 7C1 II I I � i � l f _ 4,/ ltll Ili �� % l P. .e I�� '� � Ai I MO IOC � / � c�rr� �� -k- -I ,A10. c r o /A,/ , INSTALL NEY1 CARPET r �� J _ ��� �� � + %���� �y T �_= � • �4q �. /�/ �� / r 2 ���-_ i� it I � � % / �� �ir FOR AREAS OTED AI Iii, .yza / oiE. zz 1 . 4,,,, W LLS AND " W /� CEILING DROP. � DEMOLISH � LIB REMOVE VAL NCE LIGHTS. INSTALL TR K LIGHTING A ROUND PE ( ME TER. _SE DEMDLI ON DG � � d � �, / FOR A REAS OT WS. ED _ -_ i � - _ . , . y � �� ®���� �` � � ' . I` : ;H w „ m : = -- or SYMBOLS D98 - ate 75' INTERIOR ELEVATION INDICATOR EMOLIron KEY NOTES CONSTRUOSON ly DETAIL INDICATOR p-t FINISH INDICATOR S E C O N D FLOOR P L A N IIIIIII1111 SCALE WALL LEGEND NEW FULL HEIGHT WALLS (VARIES) :TASTING WALLS TO REMAIN WALLS TO BE DEMOLISHED JL-LJ AREA NOT IN SCOPE OF WORK II • • • AREA IN SCOPE OF WORK 1 - DRAWING INDEX 30x42 sheets 0 - 1 1 -1 1-3 COVER SHEET GENERAL NOTES PARTITION 4 DEMOLITION PLAN FLOOR FINISH PLAN CEILING 4 LIGHTING PLAN DETAILS INTERIOR ELEVATIONS STANDARD LOCATIONS CODE INFORMATION ZONING: OCCUPANCY: PROJECT TYPE: CONSTRUCTION TYPE: AREA OF IMPROVEMENT: CONSTRUCTION COST: SPRINKLER SYSTEM: MECHANICAL SYSTEM: ELECTRICAL SYSTEM: The Bon Marche M- DEPARTMENT STORE Tenant Improvement Type 0 -N sprinkled 5000 square feet $65000. 00 Existing, fully sprinkled modification Incidental to the work as noted on plans, bidder design (modify existing as required In areas of drop ceiling) Existing system Modification Incidental to the work 40 noted on plans bidder design Existing, modify lighting to new layout as noted on plans, bidder design STRUCTURAL: TAX PARCEL No.: GOVERNING AGENCY: No structural work 262304 -5086 City or Tukwila Department of Community Development Building Division 6300 Southcenter Boulevard Tukwila WA 58188 tel: 206. 431. 3610 fax: 206, 431.3665 SEPARATE PERMIT REQUIRED FOR: ❑ !(PNCHANICAL ELECTRICAL 0 PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION sua;act to -- Novas e.t.a the violation of any .- ao0 or u,MleDe. 0.0.51 of commix, 0 or °80:°74 Pblla 00.0051135 0 No FILE COPY htVSJIUIV NO CHANGES SHALL BE t L TO THE COPE OF WORK WIT WITHasT PRIOR 4' ,VOL OF BU f" -sic PROJECT DIRECTORY SITE ADDRESS: (AMER: ARCHITECT: GENERAL. CONTRACTOR The Son Marche 500 Southcenter hall Tukwila, Washington 98188 Contact: t e206 656. 6001 fax 205. 555. 6001 Federated Department Stores Inc- 1 West Seventh 5t. Cincinnati, Ohio 45202 C ontact: t 1 513 5191382 Fax: INTERIOR DESIGN The Bon Marche Third Avenue and Pine Street Seattle Washington 98181 Contact Tamryn Bendix tel: 206. 506.1142 fax 205.505.1140 William Polk Associates 100 Post Alley Seattle, Washington 98101 Contact. Eric Barritt tel 206. 522. 8443 fax: 205. 522. 8031 Puget Sound Builders 18852 - 12 Avenue, 5. Kent, Washington 95032 Contact: tel: 425. 251. 1551 fax: 424.251.1658 CITY OF (11114UA N "lO',f0 SE 0 9 1950r GENERAL NOTES I. ALL CON(',; RUCTION SHALL COMPLY WITH THE FOLLOWING CODES (LATEST 43150 S3 1591 UNIFORM BUILDING CODE 1555 NATIONAL ELECTRICAL CODE AND WASHINTON STATE ENERGY CODE UNIFORM FIRE COPE BULLETIN' 13 UNIFORM MECHANICAL CODE AND LOCAL CODES AND ORDINANCES WHICH ARE MORE STRINGENT. 2. GENERAL CONTRACTOR SHALL INSPECT SITE AND VERIFY ALL CONDITIONS AND DIMENSIONS BEFORE STARTING WORK NOTIFY STORE PLANING OF ANY DISCREPANCIES. DO NOT ALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS 0HCLLN 021 THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY STORE PLANNING IF ANT DISCREPANCIES ARE FOUND. 3. CONTRA40R5 DUTIES SHALL INCLUDE: A KROVIDE AND PAY FOR I - LABOR MATERIALS AND 055 PMENT. 2 - TOOLS CONSTRUCTION AND MACHINERY. 3 - OTHER FACILITIE5 AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE 505C UNDER THIS CONTRACT. 5. I1 EOURE AND PAT FOR ALL PERMITS, LICENSES AND FEES. O. f AY ALL REQUIRED TAXES AND LABOR D. GIVE WRITTEN NOTICE OF CHANGES OR SUBSTITUTIONS IN ADVANCE FOR APPROVAL. ` E. ,p.L DESIGN CHANGES TO BE APPROVED. BY STORE PLANNING. WCR: WITHOUT WRITTEN APPROVAL MAY BE ASKED TO BE CHANGED 'AT NO EXPENSE TO THE OWNER 4. GENERAL, IS RESPONSIBLE FOR THE PROPER 00002 NATION OF WORK �0F ALL TRADES AND TO INSURE THAT ALL FLOORING, WALLS, OPENINGS, LIGHTING,IVEENTS, GRILLES, SPRINKLERS, CONDUITS, AND PIPING ARE PROVIDED FOR AND PROPE�RLLY INSTALLED AND PROPERLY LOCATED. 5. UMENEVEI FEASIBLE, CONCEAL ALL ELECTRICAL AND MECHANICAL ITEMS IN NEW CONSTRUCTION. COORDINATE ALL EXPOSED ITEMS WITH STORE PLANNING. ■ 6. VERIFY DEPTH AND LOCATIONS OF EXISTING FRAMING. PROVIDE ADDITIONAL BLOCKING 43 REQUIRED. PATCH AND REPAIR WOW TO MATCH 401411NG ADJACENT SURFACES. PATCH All SURFACES DAMAGED OR DISFIGURED. BY WORK CINDER THIS CONTRACT: INCLUD1N0 HOLES LEFT BY THE REMOVAL OF EXISTING ITEMS OR EQUIPMENT. FINISH ALL EXPOSED SURFACES. '1. WHERE WALLS ARE NOTED TO BE REMOVED, PATCH ALL ADJACENT SURFACES, WALLS 041LING, AND FLOORS AS REQUIRED PER FINISH SCHEDULE. B. CONTRACTOR TO PROVIDE DUST BARRIER DURING DEMOLITION AND OONSTRNCTICN 5 CO 15.110TOR 15 RESPONSIBLE FOR THE DAILY CLEAN UP AND REMOVAL OF DEBRIS BEFORE I;EAVING J00 01TE. 10, OQNTRAOTOR 15 TO SUBMIT °A5- BUILT. DRAWINGS OP ALL MODIFICATIONS TO HVAC, MECHANICAL, ELECTRICAL, SPRINKLERS, AND PARTITIONS 10 THE BON MARCHE STORE PLANI4k DEPARTMENT UPON COMPLETION OF THIS JOB. 11. CONTRACTOR TO PROVIDE (3) THREE SAMPLES OF EACH PAINT. AND FINISH MATERIALS AS AS SPECIFIED. ALL SAMPLES TO BE REVIEWED AND APPROVED BY MORE PLANING. 12. PROVID SHOP DRAWINGS OF ALL PERIMETER FREESTANDING AND MISC. 011570M FIX- TURES, PRIOR TO FABRICATION FOR REVIEW AND APPROVAL BY STORE PLANNING, 13, CONTRACTOR AND SUBCONTRACTOR TO COMPLY. WITH THE BON MARCHE STORE SECURITT POLICY 14. ITEMS 555010ED ON 51416 PROJECT SHALL BE ORDERED WITHIN TWO WEEKS OF THE BID AWARD TO MEET CONSTRICTION EXPENSE PUE TO UNTIMELY DELAYS AND SELECTION OF ALTERNATES SHALL NOT BE TO THE.OINER - ' 15. 41L DESIGN CH45pE0 TO BE REVIEWED AND APPROVED BY STORE PLANING. ANY WORK PERFOR1ED WITHOUT APPROVAL MAT BE ASKED TO BE CHANGED AT NO EXPENSE TO OWNER 16. 5440 INTENT OF THE DRAWINGS 15 TO SHOW GENERAL SCOPE OF THE WORK METHODS. AND MATERIALS NOT EXPLICITLY IMPLIED ARE MENDED TO BE CONTRACTOR DESIGNED WITH METH053, MATERIALS, AND PROCEEDURES SUBMITTED TO OWNER PRIOR TO START OF WoRC IN SPECIFIC THE AREA 11ac wof� .. THE BON MARCHE STORE PLANNING THIRD & PINE, 7th FLOOR SEATTLE, WA 98181 206-508-7201 0 � J FILE NAME: 9001 ems, NOTED DRAWN 01, 0.0, DATE: JULY 1990 0000180 ITYOPTUIQY UL31199O _1 PERMIT OENTER J J c Q i 0.D 5 :. to J • it! - cA � z O • Q W N U Q N z - tU O w zz - • 4 LU t) Lu Z 111 U O N 4 v 0 O - w U c() ,,,e-4 .11" 1 0 4... /. 4 4 1 ' 1 LMUUltT ',LMOOirr f WOMENS LOUNGE FITTI G ROOM SEFDEMBLI-T49N- IDWGS -- - SE€- DEMOLITION -DEMOLITION- MS_ I SAND FINISH DRAWINGS . AND FINISH DRAWINGS I3 19 (I) 2l 22 23 24 25 24' -0" r I 1 li 1- I'll -05, - r � r - � II ♦ err i Ir / I nh�/ I I �Irtll�, /0-,.• .'► '� �� ` �� + � � f /lil O % 41,0; i ce' r , . /i /� %t� II r I� I H I .. r - d � / � / �f � fora ;A � , 7 H S // i. 7C1 II I I � i � l f _ 4,/ ltll Ili �� % l P. .e I�� '� � Ai I MO IOC � / � c�rr� �� -k- -I ,A10. c r o /A,/ , INSTALL NEY1 CARPET r �� J _ ��� �� � + %���� �y T �_= � • �4q �. /�/ �� / r 2 ���-_ i� it I � � % / �� �ir FOR AREAS OTED AI Iii, .yza / oiE. zz 1 . 4,,,, W LLS AND " W /� CEILING DROP. � DEMOLISH � LIB REMOVE VAL NCE LIGHTS. INSTALL TR K LIGHTING A ROUND PE ( ME TER. _SE DEMDLI ON DG � � d � �, / FOR A REAS OT WS. ED _ -_ i � - _ . , . y � �� ®���� �` � � ' . I` : ;H w „ m : = -- or SYMBOLS D98 - ate 75' INTERIOR ELEVATION INDICATOR EMOLIron KEY NOTES CONSTRUOSON ly DETAIL INDICATOR p-t FINISH INDICATOR S E C O N D FLOOR P L A N IIIIIII1111 SCALE WALL LEGEND NEW FULL HEIGHT WALLS (VARIES) :TASTING WALLS TO REMAIN WALLS TO BE DEMOLISHED JL-LJ AREA NOT IN SCOPE OF WORK II • • • AREA IN SCOPE OF WORK 1 - DRAWING INDEX 30x42 sheets 0 - 1 1 -1 1-3 COVER SHEET GENERAL NOTES PARTITION 4 DEMOLITION PLAN FLOOR FINISH PLAN CEILING 4 LIGHTING PLAN DETAILS INTERIOR ELEVATIONS STANDARD LOCATIONS CODE INFORMATION ZONING: OCCUPANCY: PROJECT TYPE: CONSTRUCTION TYPE: AREA OF IMPROVEMENT: CONSTRUCTION COST: SPRINKLER SYSTEM: MECHANICAL SYSTEM: ELECTRICAL SYSTEM: The Bon Marche M- DEPARTMENT STORE Tenant Improvement Type 0 -N sprinkled 5000 square feet $65000. 00 Existing, fully sprinkled modification Incidental to the work as noted on plans, bidder design (modify existing as required In areas of drop ceiling) Existing system Modification Incidental to the work 40 noted on plans bidder design Existing, modify lighting to new layout as noted on plans, bidder design STRUCTURAL: TAX PARCEL No.: GOVERNING AGENCY: No structural work 262304 -5086 City or Tukwila Department of Community Development Building Division 6300 Southcenter Boulevard Tukwila WA 58188 tel: 206. 431. 3610 fax: 206, 431.3665 SEPARATE PERMIT REQUIRED FOR: ❑ !(PNCHANICAL ELECTRICAL 0 PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION sua;act to -- Novas e.t.a the violation of any .- ao0 or u,MleDe. 0.0.51 of commix, 0 or °80:°74 Pblla 00.0051135 0 No FILE COPY htVSJIUIV NO CHANGES SHALL BE t L TO THE COPE OF WORK WIT WITHasT PRIOR 4' ,VOL OF BU f" -sic PROJECT DIRECTORY SITE ADDRESS: (AMER: ARCHITECT: GENERAL. CONTRACTOR The Son Marche 500 Southcenter hall Tukwila, Washington 98188 Contact: t e206 656. 6001 fax 205. 555. 6001 Federated Department Stores Inc- 1 West Seventh 5t. Cincinnati, Ohio 45202 C ontact: t 1 513 5191382 Fax: INTERIOR DESIGN The Bon Marche Third Avenue and Pine Street Seattle Washington 98181 Contact Tamryn Bendix tel: 206. 506.1142 fax 205.505.1140 William Polk Associates 100 Post Alley Seattle, Washington 98101 Contact. Eric Barritt tel 206. 522. 8443 fax: 205. 522. 8031 Puget Sound Builders 18852 - 12 Avenue, 5. Kent, Washington 95032 Contact: tel: 425. 251. 1551 fax: 424.251.1658 CITY OF (11114UA N "lO',f0 SE 0 9 1950r GENERAL NOTES I. ALL CON(',; RUCTION SHALL COMPLY WITH THE FOLLOWING CODES (LATEST 43150 S3 1591 UNIFORM BUILDING CODE 1555 NATIONAL ELECTRICAL CODE AND WASHINTON STATE ENERGY CODE UNIFORM FIRE COPE BULLETIN' 13 UNIFORM MECHANICAL CODE AND LOCAL CODES AND ORDINANCES WHICH ARE MORE STRINGENT. 2. GENERAL CONTRACTOR SHALL INSPECT SITE AND VERIFY ALL CONDITIONS AND DIMENSIONS BEFORE STARTING WORK NOTIFY STORE PLANING OF ANY DISCREPANCIES. DO NOT ALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS 0HCLLN 021 THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY STORE PLANNING IF ANT DISCREPANCIES ARE FOUND. 3. CONTRA40R5 DUTIES SHALL INCLUDE: A KROVIDE AND PAY FOR I - LABOR MATERIALS AND 055 PMENT. 2 - TOOLS CONSTRUCTION AND MACHINERY. 3 - OTHER FACILITIE5 AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE 505C UNDER THIS CONTRACT. 5. I1 EOURE AND PAT FOR ALL PERMITS, LICENSES AND FEES. O. f AY ALL REQUIRED TAXES AND LABOR D. GIVE WRITTEN NOTICE OF CHANGES OR SUBSTITUTIONS IN ADVANCE FOR APPROVAL. ` E. ,p.L DESIGN CHANGES TO BE APPROVED. BY STORE PLANNING. WCR: WITHOUT WRITTEN APPROVAL MAY BE ASKED TO BE CHANGED 'AT NO EXPENSE TO THE OWNER 4. GENERAL, IS RESPONSIBLE FOR THE PROPER 00002 NATION OF WORK �0F ALL TRADES AND TO INSURE THAT ALL FLOORING, WALLS, OPENINGS, LIGHTING,IVEENTS, GRILLES, SPRINKLERS, CONDUITS, AND PIPING ARE PROVIDED FOR AND PROPE�RLLY INSTALLED AND PROPERLY LOCATED. 5. UMENEVEI FEASIBLE, CONCEAL ALL ELECTRICAL AND MECHANICAL ITEMS IN NEW CONSTRUCTION. COORDINATE ALL EXPOSED ITEMS WITH STORE PLANNING. ■ 6. VERIFY DEPTH AND LOCATIONS OF EXISTING FRAMING. PROVIDE ADDITIONAL BLOCKING 43 REQUIRED. PATCH AND REPAIR WOW TO MATCH 401411NG ADJACENT SURFACES. PATCH All SURFACES DAMAGED OR DISFIGURED. BY WORK CINDER THIS CONTRACT: INCLUD1N0 HOLES LEFT BY THE REMOVAL OF EXISTING ITEMS OR EQUIPMENT. FINISH ALL EXPOSED SURFACES. '1. WHERE WALLS ARE NOTED TO BE REMOVED, PATCH ALL ADJACENT SURFACES, WALLS 041LING, AND FLOORS AS REQUIRED PER FINISH SCHEDULE. B. CONTRACTOR TO PROVIDE DUST BARRIER DURING DEMOLITION AND OONSTRNCTICN 5 CO 15.110TOR 15 RESPONSIBLE FOR THE DAILY CLEAN UP AND REMOVAL OF DEBRIS BEFORE I;EAVING J00 01TE. 10, OQNTRAOTOR 15 TO SUBMIT °A5- BUILT. DRAWINGS OP ALL MODIFICATIONS TO HVAC, MECHANICAL, ELECTRICAL, SPRINKLERS, AND PARTITIONS 10 THE BON MARCHE STORE PLANI4k DEPARTMENT UPON COMPLETION OF THIS JOB. 11. CONTRACTOR TO PROVIDE (3) THREE SAMPLES OF EACH PAINT. AND FINISH MATERIALS AS AS SPECIFIED. ALL SAMPLES TO BE REVIEWED AND APPROVED BY MORE PLANING. 12. PROVID SHOP DRAWINGS OF ALL PERIMETER FREESTANDING AND MISC. 011570M FIX- TURES, PRIOR TO FABRICATION FOR REVIEW AND APPROVAL BY STORE PLANNING, 13, CONTRACTOR AND SUBCONTRACTOR TO COMPLY. WITH THE BON MARCHE STORE SECURITT POLICY 14. ITEMS 555010ED ON 51416 PROJECT SHALL BE ORDERED WITHIN TWO WEEKS OF THE BID AWARD TO MEET CONSTRICTION EXPENSE PUE TO UNTIMELY DELAYS AND SELECTION OF ALTERNATES SHALL NOT BE TO THE.OINER - ' 15. 41L DESIGN CH45pE0 TO BE REVIEWED AND APPROVED BY STORE PLANING. ANY WORK PERFOR1ED WITHOUT APPROVAL MAT BE ASKED TO BE CHANGED AT NO EXPENSE TO OWNER 16. 5440 INTENT OF THE DRAWINGS 15 TO SHOW GENERAL SCOPE OF THE WORK METHODS. AND MATERIALS NOT EXPLICITLY IMPLIED ARE MENDED TO BE CONTRACTOR DESIGNED WITH METH053, MATERIALS, AND PROCEEDURES SUBMITTED TO OWNER PRIOR TO START OF WoRC IN SPECIFIC THE AREA 11ac wof� .. THE BON MARCHE STORE PLANNING THIRD & PINE, 7th FLOOR SEATTLE, WA 98181 206-508-7201 0 � J FILE NAME: 9001 ems, NOTED DRAWN 01, 0.0, DATE: JULY 1990 0000180 ITYOPTUIQY UL31199O _1 PERMIT OENTER J J c Q i 0.D 5 :. to J • it! - cA � z O • Q W N U Q N z - tU O w zz - • 4 LU t) Lu Z 111 U O N 4 v 0 O - w U c() V 4IT C ' I 44, ,t - AI I // 1 At h �j I 1 r .. i MIME • O 1 r*rtiiii'— _ go or= I' 40 !I ' 1 � III �r— IP J pi /�DwFrD ReWw mml ,1 /, +'� ' III 6 /95 I � 194 r� , -- WWBWWO • i / R ' A / r _ ,_z ri I ` : ;y 92 ® 90 I 49 ' ', i 1 1 � ` I a ® I E Ai 'R 8 I ro ZI- O 1 � � 1� IIG -�f : ' z r'a'r o ° i �� - vx° ,,.ELL rrFI raIL _ - -F ',; ® I ® � 1 e��� WA Nlr 'YlFmW WL — W EWrM6 11'11!! T .88 MEV* TM 0 W ,B 2 i l 1 Y Millil -L 9F 11 e ttn segue EfEO PAW E7 t = ro eE P.Nrm m' �� �_.� iin BeWi• I...... SiGBGiG ■ ■ I F-- IFirjr M`J�!! ■�I.��AIIHI •� i / r IY, ,■■,� 1011E .. :7 -- . 1 .Q -- ■.I l I��i z I �p Llrll ' I Y * d loo 40 Adri _._ _._ ._. ' - mikK I ._._. _ 4 . m �.i Ask C ,, I mEE �r ALL IEW OABD� �� 0 22 23 24 V 4IT C ' r- `Il�� -AurarAmeYi 0,2 i MIME • O I Aw cmEr; 1� 96 1 frifiV.WZi /95 I � 194 r� , -- • i j , _ ,_z ` : ;y 92 ® 90 I 49 ai i Ai 'R 8 O 'rnsrEr L ' ® I WA Nlr 'YlFmW WL — W EWrM6 -Z 4: ® 1 1 }m,oc FmlG raH FOxnncro ll II `A I ��1r ttn segue EfEO PAW = ro eE P.Nrm m' J LI ■ ■ 1 _ ' � 1011E .. :7 -- . 1 .Q -- ■.I l I��i z I �p Llrll ' I Q it L® /1111 7- I� / / I� � �ill � I I�.,,fir i�/, � I ._._. _ 4 . m �.i Ask ..._........ �r ALL IEW OABD� �� EMOS1 0 22 0 0 IIIIIIIII Iq�4hl I DEMOLITION - SCOPE OF WORK NEW CONSTRUCTION - SCOPE OF WORK CONSTRUCT NEW WALLS AS NOTED (PROVIDE SLOTTED STANDARDS WHERE NOTED) (NEW WALLS NOTED WITH SOLID FILL LINE) REALIGN SALVAGED FLOOR TILES TO MATCH EXITING TILE PATTERN CONSTRUCT NEW CEILING DROP TO ALIGN WITH EXISTING - REFER TO WALL SECTIONS (31 INSTALL NEW FITTING RM. DOOR IN NEW RR DEMOLISH WALLS IN AREAS NOTED DEMOLISH AND MODIFY CEILING DROPS - REFER TO WALL SECTIONS DEMOLISH EXISTING CARPET IN AREAS NOTED REMOVE EXISTING FLOOR TILES AND SALVAGE FOR NEW AREA DEMOLISH EXISTING VALANCE MD LIGHTING IN AREAS NOTED DEMOLISH EXISTING FITTING RM. WALL PARTITIONS AND DOORS IN AREA NOTED REMOVE EXISTING DOOR MD FRAME IN OFFICE (OFFICE TO BE CONVERTED TO F.R) O PARTITION / DEMOLITION PLAN ECALE I /S" • I' -0" FINISH LEGEND P-i PAINT - BENJAMIN MORE COLOR: WHITE DOVE - EGGSHELL FINISH LOCATION: WALLS MD CEILINGS WHERE NOTED CARPET - HARBINGER STYLE: CHAMPLAIN COLOR: CI-IM-913 EAGLE BAY LOCATION: GENERAL AREA CARPET - MILLIKEN STYLE: 15041/80854 COLOR: TM LOCATION: BORDER 0 RUBBER BASE STYLE: BON MARCHE - STORE PLANNING TO ADVISE PAINT - BENJAMIN MORE - COLOR 905 COLOR: 905 LOCATION: WALLS MD CEILINGS WHERE NOTED FINISH PLAN SCALE I /8" 1.0 NEW NOM AB MitaMOOF LDOW.. CITY OF 10111/119 am10vm SEP 001009 THE BON MARCHE STORE PLANNING THIRD 8 PINE, 7th FLOOR SEATTLE, WA 98181 208.508.7201 11 .1/ 2 WIL MA H. F STALE U OF WISH FILE NAME: B SCALE: NOTED DRAWN BY E DATE: JULY 199e rz CREGISTEREO ARCH1TE6Tl RECENEO CIT'OFTUNWI JUL 3 1 1998 REFLECTED CEILING PLAN LEGEND SYMNX DESCR PBON ,... 0731NG 48' L FLUSH MINDED DOUBLE THE FLUORESCENT OMIT RXIURE - EDSTNIG 48" L FLUSH MOUNTED SINGLE TUBE RUIESCEDT OMIT RXNRE EDSIING 24,24 FLU0I MONIED AL IT UGM 0XD9E MOUNTED TO PLASTER OU GYP. 8I CEID10 ❑ USING NG 2 TO LAY-MI 4124. 0ECESS MOUNTED RUORESCEIT LIGHT FIXTURE wN1ED 00.115 N❑ NEW 24' #P REC63 MOUNTED FLUORESCENT UIR FIXTURE MINTED 10 LAY-WI 0X010 n 0051105 e I RECESSED NON- DRECDCNN. OONBICHT • FOBDNG 8• 4 RECESSED DIRECTIONAL DOMN JGHT , DOSING RU91 MINTED TRACK UNIT UNIT. (LENGTHS VARY) TO BE REMOVED AND REUSED N NEW TRAIL 0011010 LAY UT 16 NEW CONPACF FUIORESCENT WATLWAII / FLOOD - TRACK FIXTURE Q 025100 24' X 48' FLUSH MOUNTED FLUORESCENT DOR FIXTURE r1 DOSING it 5 48' FLUSH MINTED FLUORESCENT LIGHT RXIURE p DOMINO 1Y X 24' FLUSH MOORED FLUORESCENT )UNIT FIXTURE ❑ WSONG 18' X 24' FLUSH MINTED P01005 011 LICHT FIXTURE m DOSING 8' X 10'-0' FLUSH MOUNTED FLUORESIENT LIGHT ROUE • EXISTING ABANDONED 8' 4 RECESSED DORMANT C DOSING 24' 4 RECESSED FLUORESCENT URN FIXTURE NTH 12' TIN MOUNTED TO GDP. BD. CR PLASTER GERBIG pa DOSING FLUSH MINTED SRO DEGREE CAMERA Q EOSINS 22' 4 RUSH MOUNTED A/C WILE ® DOSING 24' 4 RU91 MOWED A/C GRUE • COSTING 12' 4 FUOSI INVITED A/C GRILLE Oil DOSING 20" X 30" FLUSH MONIED A/C GRILLE ul 005TNO IY 5 FLUSH MOUNTED A/C ORME RI COSTING 1122' XX 14' RUSH E OWE ® NMOUNTTE/DCA/C 11W 24 E aTO • DOMING CBLNG MOUNTED SPRINGER HEAD • COSTING FLUSH MOUNTED CEILING TREMOR) W/ GAME EDSTNG FLUSH MOUNTED CUING FAN EXIT COSTING DOT 9GN CONT. TOP TRACK, BRACE TOP OP WALL TO STRICT. ABV., NEW STANDARDS HEIGHTS TO MATCH EXISTING EXISTING WALL CONSTRICTION 20 GA. MTL. STUDS • 24" 00 ALIGN w/ STANDARDS (SEE STANDARDS LOCATIONS ON DOW. I - 5/8" GYP. 00.014 (U SIDE w/ I" SLOTS a Pos. METAL EDGES ON ALL EXPOSED CORNERf 2 NOTE NEW WALL CONSTRUCTION SAME - SEE DIG. I - FOR LOCATIONS INSTALL NEW WALL BASE AS SCHEDULED CONT. BOTTOM TRACK, SECURE TO FLOOR SYSTEM EXISTING FLOOR SYSTO I X 98 -ozcoo PAINT P -1 COLOR • DOVE WHI PAINT P -I5 COLOR - NOT w EXISTING CEILING DROP TO REMAIN NEW CEILING DROPS TO BE 20 GA MTL. STUDS • 24" 00. 5/5" GYP. BD. ON (U SIDE (---T-BAR CEILING O WALL SECTION SCALE 1' 1.0" CONT. TOP TRACK, BRACE TOP OF WALL TO STRICT. ABV., XISTING PAINT P -I5 COLOR - 905 PAINT P -I COLOR • DOVE WHITE REMOVE VALANCE LIGHTING AND CLOSE UP OFENING WITH MTL. STOS, AND 5/8" GYPSUM BD. EXISTING DRYWALL TO REMAIN T -BAR CEILING O WALL SECTION SCALE V 1' -0" PAINT P -I COLOR - DOVE WHITE NO DEMOLISH CEILING DROP AND VALANCE LIGHTING REMOVE STUDS AND MAKE GOOD FINISH ON EXISTING DRYWALL CEILING DROP CO 0 EXISTING WALL CONT. TOP TRACK, BRACE TOP OF WALL TO STRJCTURE ABOVE SEE DUCT. ( POP LENGTH OP 8 I FOR PLACEMENT APP. EXG. PARTITION w/ OR w/o RECESSED STANDARDS NEW PURRED OUT WALL TO CEILING I I/2" MTL. SIDS. 20 GA. a 24' 00. ALIGN w/ STANDARDS (SEE STANDARDS LOCATIONS ON DIW.1 -1) 5/8" GYP. BD. ON ID SIDE w/ I" SLOTS • 2 "os. METAL EDGES ON ALL EXPOSED CORNE EXISTING GALL BEHIND INSTALL NEW WALL BASE AS SCHEDULE COIN. BOTT01 TRAGIC, SECURE TO FLOOR SYS EXISTING FLOOR SYST NEW CEILING DROP 20 GA MR. STUDS • 24° O.O. 5/8' GYP. BD. ON (U SIDE W 10 0 C T -BAR CEILING O WALL SECTION SCALE P' 1' -0" mONAPtTDaeuei AA ID :� I I �I �i ■_�■ ■L! / ■■/ ■■ ■' ■■■ ■ LLJ ■!!!!li ■ ■ ■tl� ■ ■■ t�i ■ ■:0 7�jF��■■ /�1 /0 ■I■0II NI►I■/ . AI�I111MOi' i i■■ ■■■■■ ■■■■ 1111111111.610 ■ ■■■■■■ ■■ ■■■ T - I V/■L�■■N011I■■ r - � ►1 / Am mom■O■■,m■/ i S ■g■■■■■■ ''4�mai. s ■.■■ m ■ 1 < O ■ ■ ■ ■U ■■ ■■ ■41 • 'ioiiioi�■•ioiii ■G 0 'H�.�■.■■ ■.■■■■.■fi ® ■C`7 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■■ i ■Li■■ ■ ■ ■o■■■.■■ ■1 ml'i■ ■■ ■■■ ■/+ ■ ■■ 1 tli° m■a■■■.LA■■.i m O ■ ■■o ■■■ ■o■■■ ■o■M ■.e■t eta* E ■■■■rl■■rE ,�toQ*e■i■fiMN 1R miEE7■■■ niN ■ ■l dr'AMILr ■■■■ ■ ■■■.■■ II�1 ■ 1 1 ■i■.I ■ ■ ■ ■ ■■■■ ■ ■ ■ IIU .1I ■■fl■■■ ■o ■ ■■■ ■o■■■`JOL=a ■■i■■■■■■■■■■■■■■■■■■M ■f.■■■.■■■.■■■■■■_■■■ 1 i ■,1 ■ ■ ■ ■u•• ■ ■ ■ ■ ■ ■■ ■■ ■I ■tl7 ■ ■ ■ ■ 7z "n -A' .* M■■ ■ ■■■■■ 1 •11•0u■■o■u ■■■o ■■u■■0 ■A .it.iAi.iiTi.iiii.iAii.ii PR,■■■■MME'EM2m t■■■■E unrommatommillammilmm . /'■■■■■■■u■■'msu■ ■©, ■■larim ■ ■■■■■■ ■memo■ ■i mminumgmest /4P-w■All■mmRl■■ 7 CHIN N■i' . rg5' 9 ■BAR. ■i ■■ /'. ■■i/■ / ■ ■/ /■M/■ ■■■M■ A.■■■.■/a■.■■■ i■►.■■■■ _I■ /.■►■■ I■■■■►/■►/■►■ ■I ■■■M■■■ /■■■ ■I r1.■ /■► /■O /.► ' 0 J ■ /■ ■■■ ��' �' �' ■�■e ■�u■ Dia ' t 1 / tl ■■ ■■■■■= ■ ■ ■ .■i■ ■ ■u ■e■►/ ►E :1 1M0PMh�LA■ ■A■�/ ■■0■■@4'E AIM ■■■ ■s ■/■ /. 4 ' ii' ii■ L�7ig■■ L` i■ 'EM1"'..TREM■.■ ■ ■ ■ ■■■■ ■! ■ ■. ■ ■ ►- , ' Aiy w -�i Y Ng i■tl'Nim'am■■�■ /■■■■ ■ ■EI��ut em i'Li�3 i n� - oFiii■iiEMLA..i■.iENEFiyf►Ai � � .It�1 ■ ■ ■ ■ ■i ■••■M I�"i /. ►I. ■ ■ ■' ,. l lH� I� , � ' - ■a ■ ■ o■ r3 ■■■ ■■KIWI ■ ■■■■■■■■ INIU /EO /'�M ■■i■■■■■IJ �allril•il� ININE�ra��i�■ INEME %NE' ....ammmlammm ■mAm.- �5.momm/ . 11 Y askew= WPMEOVE Aiki awwwwwwwwwwww -- _ �.= POI DENSE G. DEI EXISTING 2'52' LAY - IN CLG. 0 11' -0 ot * AT RECO MU CELNE MP lail PxOREB AO IS FE LONEE TD All I � SECOND FLOOR CEILING PLAN 1111 11/ SCALE I/8" • 1' -0° THE BON MARCHE STORE PLANNING THIRD 8 PINE, 7th FLOOR SEATTLE, WA 98181 208.508.7201 FILE NAME, a80 SCALE: NOTED DRAWN WS E.B. DATE: JULY 1080 REOEMEO )IN OFTUMIYI - UL 3I1990 REGISTERED ARCH M. dDEk STATE OF WASHINGTON J J 2 REMOvE FINS, EXISTING STANDARDS TO REMAIN NEW BOXED WALL REMOVE FINS, VALANCE, AND LIGHTING INSTALL NEW WD. FRAME AND TRIM PANT AS PER BON SPEC. NEW FURRED OUT WALL OVER EXISTING D98 -o2Coo - EXISTING WALL 61 1 68 NEW OPENING r 3 -0" 11 -6 69 I EXISTING , OPENING I NEW WALL NEW WALL RITIIRE FIN (NILO II II II II EQ NEW j CEILING DROP. PAINT P -I - FUTURE FIN // r-MIL.) fA� NEW WALL NEW CEILING DROP. PAINT P -I NEW CEILING DROP. PAINT P -I II ' EXISTING WALL it _IL EQ NEW BOXED COL. NEW STANDARDS NEW BOXED WALL NEW STANDARDS NEW CEILING DROP, PAINT P -I r lm 86 a-I NEW WALL VEW WALL PATCH AND REPAIR r CEILING DROP NEW WALL _ EXISTING WALL NEW STANDARDS — EXISTING CEILING DROP FAINT P -I (T'P.) REMOVE EXISTING VALANCE AND LIGHTING (TYP.) NEW FURRED CUT WALL OVER EXISTING NEW STANDARDS EXISTING STANDARDS TO REMAIN O NEW STANDARD LOCATIONS SCALE I/4" P -0" I S 89 SO EXISTING WALL EXISTING WALL EXISTING WALL PATCH AND REPAIR CEILING DROP. PAINT P -I EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN REMOVE FINS, SHELVES, VALANCE, AND LIGHTING EXISTING STANDARDS TO REMAIN O NEW STANDARD LOCATIONS SCALE 1/4" 1' -0" NEW STANDARDS NEW WALL /1 EXISTING WALL 2'- 0 "J,E4 92 NEW WALL EXISTING OPENING EXIT CORRIDOR 95 19s1 EXISTING WALL 9l EXISTING WALL EXISTING WALL STUDS AVALIBLE WITH BLOTTED INEERETS ON ONE WIDE ONLY SLOTTED INEE E/8' GWB. 3 5/8" STANDARD STUD STANDARD STUD SECTION EXISTING CEILING DROP 94 EXISTING WALL EXISTING CEILING DROP PAINT P -I (TYP.) REMOVE EXISTING VALANCE AND LIGHTING (TYP) REFER TO FINISH PLAN FOR PAINT FINISH (TYP.) EXISTING STANDARDS TO REMAIN NEW RUBBER BASE MP.) EXISTING CEILING DROP PAINT P -I (TM REFER TO FINISH PLAN FOR PAINT FINISH (TYP.) EXISTING STANDARDS TO REMAIN NEW RUBBER BABE ITYP.) EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN CITY OF TIIKWIIA APPROVED SET U 9 1998 AS NO BUILDING OIVIS:ON THE BON MARCHE STORE PLANNING THIRD 8 PINE, 7th FLOOR SEATTLE, WA 98181 208 - 508.7201 FILE NAME: SEO18 SCALE: 1/4'•1'-0" DRAWN BY: E.B. DATE: JULY MO REGISTERED JOro: 457 LA w AL311998 =3 .MIT CENTER g ® �p g p� n 3N� STANDARD LOCATIONS INTERIOR ELEVATIONS I I N III III //// PrIA:FW 7 Aa; o ;Am mimi I 1. _Q12,_012'_Q'2'_Qi2•_Ql ,4 RSHR EM6TYYa BTA1DMID62' -74" OWTRtleTADA e ro I 1'- 0,• �2• xerailal MS° WPM VIS114 YU. ' I - r WALL ] ^ p AD RR. WIN NEW -A6 17.1030E AT14 A I. At21. FN 4 24 0V a RINBFx 4]406 e ry III -- �.J■ EQ 2 - 2' -0 2.-Q, EQ • I 1 -1 " 12' -3 i -T 2 B' -1i" ��r� REMOvE FINS, EXISTING STANDARDS TO REMAIN NEW BOXED WALL REMOVE FINS, VALANCE, AND LIGHTING INSTALL NEW WD. FRAME AND TRIM PANT AS PER BON SPEC. NEW FURRED OUT WALL OVER EXISTING D98 -o2Coo - EXISTING WALL 61 1 68 NEW OPENING r 3 -0" 11 -6 69 I EXISTING , OPENING I NEW WALL NEW WALL RITIIRE FIN (NILO II II II II EQ NEW j CEILING DROP. PAINT P -I - FUTURE FIN // r-MIL.) fA� NEW WALL NEW CEILING DROP. PAINT P -I NEW CEILING DROP. PAINT P -I II ' EXISTING WALL it _IL EQ NEW BOXED COL. NEW STANDARDS NEW BOXED WALL NEW STANDARDS NEW CEILING DROP, PAINT P -I r lm 86 a-I NEW WALL VEW WALL PATCH AND REPAIR r CEILING DROP NEW WALL _ EXISTING WALL NEW STANDARDS — EXISTING CEILING DROP FAINT P -I (T'P.) REMOVE EXISTING VALANCE AND LIGHTING (TYP.) NEW FURRED CUT WALL OVER EXISTING NEW STANDARDS EXISTING STANDARDS TO REMAIN O NEW STANDARD LOCATIONS SCALE I/4" P -0" I S 89 SO EXISTING WALL EXISTING WALL EXISTING WALL PATCH AND REPAIR CEILING DROP. PAINT P -I EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN REMOVE FINS, SHELVES, VALANCE, AND LIGHTING EXISTING STANDARDS TO REMAIN O NEW STANDARD LOCATIONS SCALE 1/4" 1' -0" NEW STANDARDS NEW WALL /1 EXISTING WALL 2'- 0 "J,E4 92 NEW WALL EXISTING OPENING EXIT CORRIDOR 95 19s1 EXISTING WALL 9l EXISTING WALL EXISTING WALL STUDS AVALIBLE WITH BLOTTED INEERETS ON ONE WIDE ONLY SLOTTED INEE E/8' GWB. 3 5/8" STANDARD STUD STANDARD STUD SECTION EXISTING CEILING DROP 94 EXISTING WALL EXISTING CEILING DROP PAINT P -I (TYP.) REMOVE EXISTING VALANCE AND LIGHTING (TYP) REFER TO FINISH PLAN FOR PAINT FINISH (TYP.) EXISTING STANDARDS TO REMAIN NEW RUBBER BASE MP.) EXISTING CEILING DROP PAINT P -I (TM REFER TO FINISH PLAN FOR PAINT FINISH (TYP.) EXISTING STANDARDS TO REMAIN NEW RUBBER BABE ITYP.) EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN CITY OF TIIKWIIA APPROVED SET U 9 1998 AS NO BUILDING OIVIS:ON THE BON MARCHE STORE PLANNING THIRD 8 PINE, 7th FLOOR SEATTLE, WA 98181 208 - 508.7201 FILE NAME: SEO18 SCALE: 1/4'•1'-0" DRAWN BY: E.B. DATE: JULY MO REGISTERED JOro: 457 LA w AL311998 =3 .MIT CENTER g ® �p g p� n 3N� STANDARD LOCATIONS INTERIOR ELEVATIONS III III //// PrIA:FW mimi I 1. 1WnC REMOvE FINS, EXISTING STANDARDS TO REMAIN NEW BOXED WALL REMOVE FINS, VALANCE, AND LIGHTING INSTALL NEW WD. FRAME AND TRIM PANT AS PER BON SPEC. NEW FURRED OUT WALL OVER EXISTING D98 -o2Coo - EXISTING WALL 61 1 68 NEW OPENING r 3 -0" 11 -6 69 I EXISTING , OPENING I NEW WALL NEW WALL RITIIRE FIN (NILO II II II II EQ NEW j CEILING DROP. PAINT P -I - FUTURE FIN // r-MIL.) fA� NEW WALL NEW CEILING DROP. PAINT P -I NEW CEILING DROP. PAINT P -I II ' EXISTING WALL it _IL EQ NEW BOXED COL. NEW STANDARDS NEW BOXED WALL NEW STANDARDS NEW CEILING DROP, PAINT P -I r lm 86 a-I NEW WALL VEW WALL PATCH AND REPAIR r CEILING DROP NEW WALL _ EXISTING WALL NEW STANDARDS — EXISTING CEILING DROP FAINT P -I (T'P.) REMOVE EXISTING VALANCE AND LIGHTING (TYP.) NEW FURRED CUT WALL OVER EXISTING NEW STANDARDS EXISTING STANDARDS TO REMAIN O NEW STANDARD LOCATIONS SCALE I/4" P -0" I S 89 SO EXISTING WALL EXISTING WALL EXISTING WALL PATCH AND REPAIR CEILING DROP. PAINT P -I EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN REMOVE FINS, SHELVES, VALANCE, AND LIGHTING EXISTING STANDARDS TO REMAIN O NEW STANDARD LOCATIONS SCALE 1/4" 1' -0" NEW STANDARDS NEW WALL /1 EXISTING WALL 2'- 0 "J,E4 92 NEW WALL EXISTING OPENING EXIT CORRIDOR 95 19s1 EXISTING WALL 9l EXISTING WALL EXISTING WALL STUDS AVALIBLE WITH BLOTTED INEERETS ON ONE WIDE ONLY SLOTTED INEE E/8' GWB. 3 5/8" STANDARD STUD STANDARD STUD SECTION EXISTING CEILING DROP 94 EXISTING WALL EXISTING CEILING DROP PAINT P -I (TYP.) REMOVE EXISTING VALANCE AND LIGHTING (TYP) REFER TO FINISH PLAN FOR PAINT FINISH (TYP.) EXISTING STANDARDS TO REMAIN NEW RUBBER BASE MP.) EXISTING CEILING DROP PAINT P -I (TM REFER TO FINISH PLAN FOR PAINT FINISH (TYP.) EXISTING STANDARDS TO REMAIN NEW RUBBER BABE ITYP.) EXISTING STANDARDS TO REMAIN EXISTING STANDARDS TO REMAIN CITY OF TIIKWIIA APPROVED SET U 9 1998 AS NO BUILDING OIVIS:ON THE BON MARCHE STORE PLANNING THIRD 8 PINE, 7th FLOOR SEATTLE, WA 98181 208 - 508.7201 FILE NAME: SEO18 SCALE: 1/4'•1'-0" DRAWN BY: E.B. DATE: JULY MO REGISTERED JOro: 457 LA w AL311998 =3 .MIT CENTER g ® �p g p� n 3N� STANDARD LOCATIONS INTERIOR ELEVATIONS