Loading...
HomeMy WebLinkAboutPermit D98-0264 - THINGS REMEMBERED - TENANT IMPROVEMENTD98 -0264 905 Southcenter Mall Things Remembered City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9004 Address: 905 SOUTHCENTER MALL Suite No: Location: Category: ARET Type: DEVPERM Zoning: Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Contractor License No: GRICECI024PF Permit No: Status: Issued: Expires: D98 -0264 ISSUED 10/06/1998 04/04/1999 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERS East: .0 West: .0 Streams: OCCUPANT THINGS REMEMBERED 905 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT TIM SCHENK Phone: 800- 541 -0821 ELDER JONES, INC, 1120 E 80 ST, BLOOMINGTON MN 55420 CONTRACTOR GRICE CONSTRUCTION INC Phone: 925 941 -6339 2460 CHERRY HILLS DR, LAFAYETTE CA 94549 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INTERIOR TENANT IMPROVEMENT. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 40,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: •Size(in): .00 Flood Control Zone: N Hauling: N Start. Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 900.04 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:` I hereby certify that I have read and ex.amilOrd this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. AU52.22__ Date: ,0`VACISs The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature:_ ?lb6l�v�� Date:jt9' _yy Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ( CITY OF TUKWILA Address: 90S SOUTHCENTER MALL Permit No: D98-0264 Suite: Tenant: Status: ISSUED Type: DEVPERM Applied: 08/03/1998 Parcel #: 262304-9004 Issued: 10/06/1998 kq,k***-k**********.***-0.A***AA****A4,*******4(**A***********.k*****.w****** Permit Conditions: 1, No changes will be made to the plans unless approved by the Architect or Engineer andtherTpkwilaBuilding Division. Plumbing permits shal.Lbeobtained:throilgh the Seattle-King County Department of.Public Health. Plumbing •will be inspected by that agency, including all gas piping (296-4722). 3. Electrical permits shall be obtained -through the Washington State Division of Labor and Industries and all..elettOcal work win be inspected by that aciency (248-6630). 4. All mechanical work shall be'-under separate permit issued by the City :of Tukwila. All permits, inspection records, and approved plans'shall±be avaijable at the job siteprior to the start of any_cion7 struCtion, '.These documents are to be maintained'andsaVall7T able'-.until final insOection approval is granted. Any. new ceiling grid and light fixtUre installation is required to meet lateral bracing reqUirements for Seismit. Zone 3. , . 7. Partition walls attached tO,Tceiling grid must be laterallv braced if over eight (3) feet in length_ , - 8. All...construction to he dune in conforMance with approved plans and requirements of the Uniform Building Code:(1997_, Edition) as amended, -Uniform Mechanical Code (1997 Edition) and.'MashinatonState Energy Code (1997 Edition). 9. Any exposed insulations backing•material:shall have a_Flamei: Spread Rating of 2' or less, and material. shall bear-i.dent fication Showing the fire performanevratingthereof. 10, Validity_of Permit. The issuance ofya permtt'or approval/H:6f plans, specifications, and computations Shall nut be con: strued toibe a permit for, or an approval of, anyviolatOn of any at the pr ov,isions Of _the building code or of 091:/ other or'dinance of the jurisdiCtion. No permit presiiiiiThg to give authority to violate or cancel the provisionsdf'this code shall beAral.ld. 1 CITY OF TUKWILA Permit Center ' 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 R.:S.TAFF:USE ONL. Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: H IN �� Zr/(t fixl t✓ t,: 7.p Value of Construction: oz., 4-0, 0 ----• Tax Parcel Number: - /! �G, 23 0 el- -.o6 `y" Phone: Site Address: : ' ' ` " - -- ci yt Cs :It-City State /Zip: 547% C.v f -. C- F MJ rT N Lit L i � (� l t- 4.'.l. LP A. Property Owner: P161. 46.17-0 t~ . .jACV ts ' &- gt.)Up iniG • Street Address: City State/Zip: 7 L54 Z E r z, hG .- . C i. 0 I-i Fax #: Existing fire protection features:rinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Contractor: '� t� ID l5 r- ‘--.F.,(---ft:- cfrcD Phone: Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 pa er indicating quantities & Material Safety Data Sheets Street Address: City State /Zip: Fax #: Architect: C. G. ),o Ct4-L_ucia /1.1-26.0-1 7-'c Phone: 6i'7x — z- t-5 – 6 Street Address: City State /Zip: t 5 -4- P z-c - / It C.61ZiZo LL rPrt). rg Fax #: Engineer: L/ �0 /�� JS00(� /GuLl/�tZtv( ):� Phone: 6 a z -G 26 _ 5 q5 3 Street Address: City State /Zip: Z 13 o I - /u. L.1.77E Piz' CSI -I-ci .01 x� AZ P1 507-/-2 Fax #: (oa 2- - 67 8 -- a 530 -4 Contact Person: *I/ tiI '--;Gi- 1-/ ,O14- — E.A.-D5,-(2 Jon)g-S !) aU G Phone: )---dot -54i ---o $ z / Street Address: City State /Zip: 11 20 E , & ) 714. fir. F 3 c L)v,vt /r e : ,44) ' .4 z o Fax #: 61.Z- g s - I9 o l Description of work to be done: j eivt o LIJit c_. )G y-!S T i'- / /-' Tnn(2. t0 R Tr. iuj,�.v 3' ). ifRDuldi44,� ' _ ,a Cif wi ��.) Ic IS �, 24( Existing use: Lo -etail ❑ Restaurant ❑ Multi- family ❑ Warehouse ElHospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other . Proposed use:etail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes 0/no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes ❑ no Existing fire protection features:rinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 1 .s (e' existing Area of Construction: (sq. ft.) 13 9 -' Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 pa er indicating quantities & Material Safety Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: Additional reviews ma be determined b the Public Works De.artment ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: 0 Cut ❑ Land Altering ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Water Meter /Exempt #: ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Flood Control Zone Size(s): cubic yds. 0 Fill cubic yds. ❑ Sewer Main Extension ❑ Street Use ❑ Water Main Extension Size(s): 0 Deduct Size(s): Size(s): ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shal be extended more than once. Dale application accepted: —18 Date application expires: Applicglion taken by: (initials) CTPERMIT.DOC 1/29/97 .P.LEASE:SIGN BAG (OF. APPLICATIONTQRIUI. .COMMERC/AUMULTI -PA Y•TENA'NTIMP, ROVEMENT /A. LT 'ATION PERMIT APPLICATIONS. MUST BE:SUBMITTED: WITH-THE FOLLOWING:; ALL DRAWINGS TCI BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include ❑ ® Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ® Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ® Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non- Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application . and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTO RIZED A ENT: Signature: J Date: ":2 3) Print name: ,Am.rs pvIL4 Tr ,dI ?140T IT Phone: � 4z - f�bs-4'II )v Fax #: Address -- I6 3 1 SG TH- 4.v re Ai.t, �� Cit / e /Zi y c- ouu5i " i 7 CTPERMIT.DOC 1/29/97 PVAIT47.MLIcTAT4,, 4,**********4.*************A" **•** CITY OF TUKWILA. WA *A**A**+*.A*********: TRANSMIT Number: R9700842 Amount: 547.25 101.0G/98 44.112?; Payment Methodt CHECK Notation: ORICE CONST f(pP ***********A*******A.*********A*... TRANSMIT Permit No: D9B-0264 Type: DEYPERM DEVELOPMENT PERMIT Parcel No: 262304-9004 Site Address: 905 SOUTHCENTER MALL Total Fees: 900.04 Thi P1ymjit 547.25 Totzd ALL Pmts: 900.0i Balance: ,v, . *iti,A*1%*********4-Ah*Il*A*ii***********AA4A1.7 Description Amour: BUILDING - NONRES 42.?=-., STATE BUILDING SURCHARGE 4.r;P: ic ir . *.** ACCOUTI*A0e, 000/322..100 000/3U4A;61“-VP , CITY OF TUKWILA RECEIPT PW DCD 547.25 CHECK 547.25 10/07/98 10 08:28 0097 6512 f.S12 10/07 '2710 TOTAL 547.25 ltic41,44—A*A**.A4.,1A4*A*.AA.A.A4*AA*4P-*AAW*-,%i**#4**Ikk***0**Ak4,***A*;k1C4 L1TY OF TUKWILA. WO rizoi4smiT .t.AAALA*4-*AtAtt*AA4-*A*1‘4,-AA.0,-A0,47%4:1*.4*0*ItAi4lkiA44,*k*k0AA*kAA*W4A** TRANSMIT Number: B9700204 Amount: 392.79 08/03/98 10:04 Payment Method: CHECK. fttaLlom: ELDER-.10NES BIJI Permil Mini: D98-0264 TvEle: DEVPLPM DEVELOPMENI PER1II1 Parcel No 262304-9004 5ste Arldretxs: 707 SOUTHCEN1ER MOLL Total Feet 900.04 11,1;s-4 Pavmemt 252.79 Total ALL Pmts: 352.79 Balance: 547.25 **A*A*A4v**71**A'Aiokkit**s1.***kl,43***A.kit4*******AA*A.*AA*• Account Code 000/345.830 • Descrlotion: . PLAN CHECK,- NO'1RES n 352.79 4272 08/04 7717 . TOTAL.. 352.79.— INSPECTION RECOPF) Retain a copy with pi. .iit INSPECT! S. NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 3670 Proje • ! T pe of inspecti : Addres • ( rl�� H ( Date called: p'` ,` Specia instructions: r, • 30 ' Date wanted: // /i3 9 a�T0 r% `' ,g Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 620 ,50, // Inspector; Date :ijA /g-F ri $42.06 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No.: Date: cu •ire"',. (1) INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 9818 INSPECTION RECO Retain a copy with p PERMIT NO. (206) 431 -3670 Project: -7 'rhrrk s ive,., Type of inspection: r e(S. 7",a -r Ce.< / Address: ` Date called: 8 Special instructions: late want O a.m. Req�l��t lei' A Phone No.: Approved per applicable codes. Corrections required prior to approval. -CQMMENTS: Inspector: Date// 7 9 $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: l' • c2 INSPECTION NO. INSPECTION RECOP ) Retain a copy with piLJit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Proje Type of inspection:. Addre isvuti, Date called Special instructions: Date wanted: 02� `�� a.m._ p.m. Requester. Phone No.: '2,0 to '3 - f ( r Approved per applicable codes. Corrections required prior to approval. COMMENTS: e://ei, �pF"GrT (27(9& t 2k Inspect Dateiv i $42.0s'EINSPECTION FEE REQUIRED. be paid at 6300 Southcenter Blvd., Suite,1,k0. Prior to inspection, fee must Ca I to schedule reinspection. Receipt No.: Date: - - � -i• .. :'r'� %� i z`,' �x-' T= � `r- 'a•.p��``:'ti ✓_- ;a�RxK•�re.a: ;s'i':fr }'�%S?!n".'�^T�Yi;ji =;dFiF is INSPECTION NO. I.NSP,ECTION RECD )Retain a copy with pit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tuk ila, WA 98188 0a6 PERMIT NO. (206) 431 -3670 Project noi S vt�tp ` Type of inspection: r N Address. — ,rte / Gt �"r a Date called: / O t 1 Date wanted: . `0 /z. z____ a. . Special instruction • Requester: \CV \./ G( A A Phone No.: ( 3 5 ( ) c / Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: .ii: 4)4,51 $42.00 EINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No.: Date: INSPECTION RECD Retain a copy with p . it CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 �� -COGS' PERMIT NO. (206) 431 -3670 Project: ,::... r o7,=y:. �.. Type of inspe n: Address: , Med f /Date called. Po Special instructions: l .S RQlriP Date wanted: � '0" �� Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Po J A? 4--r-1---;--27 )--j ---., 4,. 7e24.-- J _ _..._, / Inspector: Date: �12 -f3 $42.00 REINSPECTIO(V FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: City of Tukwila Fire Department John W Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM • Thomas P. Keefe, Fire Chief Permit No. >13- 0 (/ • 4)913-; ‘.496 Project Name 7/4/At 5 :P& 14-, /3 tell OD Address g"?.-,C2 dr71, // Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorii6d Signature FINALAPP.FRM Rev. 2/19/98 �7798 ate T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 PLAN EW/C�frdCopq Nci SLIP ACTIVITY NUMBER: PROJECT NAME: D98 -0264 THINGS REMEMBERED DATE: 10 -28 -98 Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # %% Revision # 2 After Permit Is Issued DEPARTMENTS: Bu in_ Division rubl c WorCC � ❑ Fire Prevention Structural /1 ❑ fa- Planning Division n Permit Coordinator It DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Incomplete LI Comments: DUE DATE: 10 -29 -98 Not Applicable ❑ TUES /THURS ROUTING: Please Route n No further Review Required Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions El DUE DATE: 11 -26 -98 Not Approved (attach comments) LI REVIEWERS INITIALS: DATE. CORRECTION DETERMINATION: DUE DATE: Approved n Approved with Conditions El Not Approved (attach comments) n REVIEWERS INITIALS: DATE: \PR- ROUTE.DOC 6/98 Peni PLAN REVI /ROUTI N 1 ACTIVITY NUMBER: D98 -0264 DATE: 10- 16 -98. PROJECT. NAME: THINGS REMEMBERED Original Plan Submittal Response to Correction Letter. # Response to Incomplete Letter XX Revision # , 1 After Permit Is Issued DEPARTMENTS: Bung Division Fire Prevention 4 ' /0- K� u•lic Wor s Structural Planni g Division ❑ Permit- DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Comments: DUE DATE: 10 -20 -98 Incomplete Not Applicable ❑ TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 11 -17 -98 Approved n Approved with Conditions Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions n Not Approved (attach comments) REVIEWERS INITIALS: DATE: \PR- ROUTE.DOC 6/98 PLA 1V REVIEW OUT�SLIP ACTIVITY NUMBER: D98 -0264 DATE: 8 -3 -98 PROJECT NAME: THINGS REMEMBERED XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter Revision After Permit Is Issued DEPARTMENTS: Dkig Division jg Fire revention 1)ife gtr(2 trut ( n DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete n Incomplete n Comments: Planning Di Permit Coordinator DUE DATE: 8 -4 -98 Not Applicable TUES /THURS ROUTING: Please Route n No further Review Required Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) n REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Ei Approved with Conditions DUE DATE: 9 -1 -98 Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved n Approved with Conditions El Not Approved (attach comments) REVIEWERS INITIALS: DATE: \PR- ROUTE.DOC 6/98 CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard„ Tukwila, WA 98188 Telephone: (206) 431 -3670 DATE: l -2.4g - PLAN CHECK/PERMIT NUMBER: 09 S ' 0 2(4 PROJECT NAME: (A-< 5 :_4/L e%ne6YEb. PROJECT ADDRESS: �. �L(_�f � )`r 6 1 x-u_.. (6) CONTACT PERSON: "1 AO Aid PHONE: ( .2Z) V53 .C//8" REVISION SUMMARY: W/q-t', - -77(r2(9-ic (- CY C/c 070D i 7-7) SHEET NUMBER(S) ) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: CITY USE ONLY RECEIVED CITY OF TUKWILA OCT 2 8 1998 PERMIT CENTER QIite& C 4 Bldg: Planning; ire P,. ublicWorks REVISION NO53119196 CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard,'Tukwila, WA 98188 Telephone: (206) 431 -3670 DATE: (( /- `/0 PLAN CHECK/PERMIT NUMBER: ,&95- OZv7' PROJECT NAME: Olt /04.5 4:-'71/ PROJECT ADDRESS: 9O r7f(f-AfTb- i4-'Gt. CONTACT PERSON: R42 v/ ,V'/U Vgeva PHONE: -2Drp 133 5715 REVISION SUMMARY: 41(/J57 p476.0" AO 4705(D,d (S 'FM) 738-7 4/20o efe 740* /6 SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: RECEIVED CITY OF TUKWILA OCT 1 6 1998 PERMIT CENTER CITY USE ONLY. Bldg. Planning;. Fire Pubhc;:Works RVISION NU. 3/19/96 City of Tukwila Fire Department Fire Department Review Control ##D98 -0264 (510) John W. Rants, Mayor Thomas P. Keefe, Fire Chief August 12, 1998 Re: Things Remembered - 405 Southcenter Mall Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575- -4404 • Fax (206) 575- -4439 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1003.5) 3. Maintain sprinkler coverage per N.F.P.A. 13. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Page number 3 Thomas P. Keefe, Fire Chief Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 4. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) 5. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 6. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .575-4404 • Fax (206) 5754439 City of Tukwila John W Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 4 Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 5754439 REGISTRATION VERIFICATION ' . ij ' 8 00 00 w CC I- C) en >0 0 ci-J= —J PERMIT CENTER ' U U KB Design Group, Inc. o 7 cb 113 West Jersey Ave. • Pitman, NJ 08071 609/589 -3110 STORE CONCEPT fax 609/589 -1770 SPECIFICATIONS G GENERAL NOTES G GENERAL NOTES F FIRE RATING LEGEND TE NT H FURNISHED I INSTALLED G h / !^ EXISTING LANDLORD INV N21 LANDLORD TEN AN T 1. C CLG TILE U USG. C CLP55 A (0 -25) ) )ASTM E 84) -S -1788 • 2 D DRYWALL U U.S.G. 1 1 HOUR ASSEMBLY U U.L. �'U465 4 4 < <OEHLER, RESIDE • CARROL (972) 245 —E Oi. 1 PRAL REQUI IS H 3. C CLG GRID U U.S.G. N N/A ( (AST C 635) R 1. PERMITS AND F • • L L R ---- -+ • N/A W 4. 3. TEMPORARY ELECTRIC N • . ._,__ - 6 ' 3 FLOOR FINISHES 02 SITE WORK P • _ _ -_ _ _ • 4 1. DEMOLITION • 1. C CARPET M MANN'TON A AVG. DENSITY -A 183 ( (WEER #513/ASTM E 662 -79) , 2. SAW CUT SLAB • 2. V V,C. TILE A ARMSTRONG C CRITICAL RADIENT FLUX ( (ASTM E 648 & E 662) a a ° 03 CONCRETE SLAB _._ - -_ r • - • _ - - - r F A ARCHITECT'S GENERAL• NOTE r / f 2. VAPOR BARRIER • WALL FINISHES ' FLAME F FUEL. S SMOKE L LAMINATE TESTS BASED • SPECIFICATIONS PRIOR TO COMMENCING ANY WORK. WE ACCEPT NO OFI FOR •' - 4. _ _ _ _ E _ _ I - 1 • 2 1. E DEMISING WALLS R 2. P PAINT S SHER WIL. 1 10 7 70 1 10 S 3 L LAMINATE I ILSONART 5 5 - - 5 5 U UNBONDED L 4. L LAMINATE W WILSONART 7 75 - - 2 20 B BONDED TO "DURAFIAKE" 3 S 5 P PART. BD. D DURAFLAKE 2 20 1 1 1 15 w 05. CARPENTRY A 6. W - B 1. BUILT -IN BASE • • O O E 2. BOARD AND BATTENS • • C • • • • B DOOR SCHEDULE I 4. ` 1 06. DOORS W NO D DESCRIPTION G 1. STOREFRONT ROLLING GRILLE • • • • ti 2. STOCKROOM DOOR 1 _ __-I A I•l I O GRILLE D 3. _TOILET ROOM DOOR _ _ _ 5. - _ -_ _ _ _ • i _ - ' • r, n l I i i y£ MUNICIPALITIES L LANDLORD 2. TAPING & SPA • • A 3. FLOORS A 1 •1•j oI .,T •',•I SNOISIA31 •I1.1 •1• •I• CLIENT Things Remembered LOCATION STORE # 840 SOUTHCENTER MALL SPACE # 572 TUKWILA, WA SO. 1T.; 1,396 SINGLE LEVEL ■ DWG. TITLE GENERAL NOTES & SPECIFICATIONS CARPET VINYL COMPOSITION TILE 2',2 ACOUSTICAL PANEL 2',4' ACOUSTICAL PANEL PAINTED SHEETROCK_ CERAMIC TILE FLO01 WOOD FLOORING COVE BASE STOREFRONT BASE PAINTED SHEETRO STOREFRONT PAN • C 141* COLOR & FINISH SCHEDULE CODE MATERIAL DESCRIPTION & SPECIFICATIONS ❑A PAINT FORMULAS - CUSTOM COLOR © PAINT SHERWIN WILLIAMS SW1183— "PLAZA SURE' (EGG SHELL) PALM SHERWIN WILLIAMS #5W1354 — "WHITE WOOL" (GLOSS) ❑D HIPLAM PIONITE #AV731 -6 SUEDE "CELEDON IMPRESSION' VINYL J.M. LYNNE #OVW4523 — 'OVERTURE" VINYL J.M. LYNNE #2401 —SN — "SIENA SEASHELL" TILE 12' X 12" 'KASHMIR CITAPRA' QUARRY TILE Q TILE 16" X 16" IMAGE CERAMIC TILE — #8050 "GRASS" O WOOD PERGO SKU #PF4000 —I — "GAO" ❑K CARPET MPNNINGTON COMMERCIAL CARPET #CARTHHEE -26 "NAUTCA" DETAIL: PERIMETER WALL SOFFIT SCALE: i " =1 -0" (ROUGH OPENING) SEE PLAN FOR LOCATION OF HINGE DETAIL: T RU DOOR OPENING SCALE: I- 1/2 " =1' -0" 54' LAY IN CEILING BY T,G.C. TOILET ROOM ELEVATIONS PAINT ALL EXPOSED SURFACES OF 5/8" TYPE X" SHEETROCK (T &S) ON 3 -5/8' METAL STUDS FRAME AS REQUIRED SUPPLIED AND INSTALLED BY PREFINISHED RIBBON BOARD SUPPLIED BY F.C., INSTALLED BY T.C.C. STAGGARD FLUORESCENT STRIP LIGHT SUPPLIED BY TENANT, INSTALLED BY T.E.C. •1 REFINISHED FASCIA BOARD SUPPLIED BY F.C., INSTALLED I I BY T.G.C. TOILET TISSUE DISPENSER Q 0 O U ^ - C ° cb _ o Z 2 g 0. • O o • a a V U . 0 o C U O W � a o 4 ) H 0 CO W 0 U O RE Au!, I) .4 1738 vERMITCENTER 98107—Al A A NOT TO SCALE LAY —IN CEILING AT T.G.0 RIBBON BOARD 5/8" SHEETROCK ON 3 -5/8" METAL SOLOS BY T.G.C. SECTION THRU SOFFIT z S DETAIL: ® SERVICE ISLAND SCALE: 1 " -1' -0" 3/4" NON —COMB PLYWOOD OVER 5/8' SHEETROCK N� 3 5/8 20ggA. MT'L STUDS AT 12 "a.c. 5/8" TYPE "X S.R CL'G AT 7' -6" LE.F. PAINTED 51 BY T.C.C. SECTION THR DETAIL: TOILET ROOM U DECK TOILET TISSUE DISPENSER WALL MOUNTED MIRROR PLUMBING CHASE WALL NOTE: MOUNT TOWEL DISPENSER w /TOWEL ACCESS AT 48" A.F.F. MAX. WALL MOUNTED MIRROR REQUIRED CLEARANCES INDICATED BY DOTTED UNE /DIMENSIONS. SERVICE ISLAND LAY —IN CEILING AT 8' -6" A.F.F. BY T.G.C. TRACK LIGHTING SUPPLIED BY TENANT IN, BY T.G.C. CERAMIC TILE DETAIL: TILE TO CARPET TRANSITION STRIP SCALE: 1 " =1' -0" — 3/4" NON —COMB PLYWOOD BY T.G.C. 2x4 WOOD STUDS O FRONT & BACK. I' -3 I/O" DETAIL: B LT N T BA E SCALE: 1— I/2 " =1' -0" 2x3 CENTER BRACING (TYP.) OAK BASE SUPPLIED & INSTALLED BY TENANT TENANT'S GLUE — DOWN CARPET CCA INSTALLER TO GLUE DOWN CARPET BASE. DO NOT STAPLE. 3/16' ZINC TRANSITION STRIP SUP'L & INSTL BY T.G.C. FLASH PATCH & WOOD BLOCKING AS REQUIRED TO INSURE A SMOOTH & EVEN TRANSITION BY T.G.C. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIII6 4 CARPET SUP'L AND INST'L BY TENANT ONCRETE SLAB METAL "L" ANGLE TRANSITION STRIP OAK WOOD FLOORING T.G.C. TO PROVIDE SHIM AS REQUIRED FROM 1/8" TO 0 -0" AS SHOWN. DETAIL: WOOD TO CARPET TRANSITION STRIP TOILET ROOM SHALL CONFORM TO ALL ACCESSIBILITY REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA) INCLUDING BUT NOT LIMITED TO: 1. WATER CLOSET SEAT HEIGHT - 17" TO 19" A.F.F. 2. CENTERLINE OF WATER CLOSET — 18" FROM SIDE WALL. 3. GRAB BAR BEHIND WATER CLOSET — 36' LONG, 33" TO 36" A.F.F. 4. GRAB BAR O SIDE OF WATER CLOSET — 42" LONG, 33" TO 36" A.F.F. 5. GRAB BAR DIAMETER — 1 1/4" TO 1 1/2" 6. SPACE BETWEEN WALL AND GRAB BAR — 1 I/O" 7. TOILET PAPER DISPENSER — 36" MAX. FROM REAR WALL. 19" MIN. AF.F. 8. KNEE CLEARANCE O LAO — APRON 29" MIN. HEIGHT, 8' MIN, DEPTH. 9. LAO DEPTH — 17" MIN. 10. LAO HOT WATER AND DRAIN PIPES INSULATED WHERE EXPOSED. 11. LAO RIM SURFACE — 34" A.F.F. MAX. 12. MIRROR BOTTOM EDGE — 40' MAX. A.F.F. 13. INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE MOUNTED ON THE EXTERIOR OF THE TOILET ROOM DOOR. 14 . PRIVACY LOCK SHALL HAVE LEVER HARDWARE HANDLES. CI('f LII IIiYYLIU AUG 2 22 23 COLOR & FINISH SCHEDULE CODE MATERIAL DESCRIPTION & SPECIFICATIONS ❑A PANT QUINSTONE INDUSTRIES - CUSTOM COLOR EB PANT SHERWIN WILLIAMS #SW1183- "PLAZA SUITE' (EGG SHELL) © PANT SHERWIN WILLIAMS #SW1354 - "WHITE WOOL" (GLOSS) Q HIPLAM PIONTE #AV231 -8 SUEDE 'CELEDON IMPRESSION' I]E MIEN. J.M. LYNNE #OVR4523 - 'OVERTURE' © VINYL J.M. LYNNE #2401 -SN - 'SIENA SEASHELL' © TILE 12' X 12' 'KASHMIR CRAPRA' QUARRY TILE ❑H TILE 16" X 16" IMAGE CERAMIC TIE - #8050 `GRASS' ❑J WOOD PERGO SKU #PF4000 -1 "0A(" �K CARPET MANNINGTON COMMERCIAL CARPET #CARTHHEE -26 'NAUTICA" LANDLORD'S NEUTRAL PIER 3/4' TH. METAL TREE GRATE, 3' DIAN. I TREE LANDLORD'S NEUTRAL PIER ®CERAMIC TILE 'GRASS' — SUP'L BY TENANT, INSTL BY T.G.C. HOW WINDS ROLLING GRILLE OPENING SHOW WINDOW T 1 SIGN PANEL SUP'L BY TENANT, INST'L BY T.G.C. (SEE SIGN MFR'S SHOP DRAWINGS FOR DETAILS.) SCALES 3 /8'=1' -O' I L 3 LEASE LINE TO LEASE LINE STOREFRONT ELEVATION L L. I DEMIS NG WAIL FINISHED KEYSTONE SUP'L BY TENANT, INST'L BY T.C.C. LNE OF SOF R AB VE 0 EWOOD FLOORING SUP'L & INST'L BY T.G.C. FROM EDGE OF TILE THROUGH STORE AS SHOWN. FLOOR & CERAM C TILE. • 5 SHOW WINDO STOREFRONT PLAN SCALES 3/8'=1' -0' ROLLING GRILLE OPENING DEMISING WALL TO DEMISING WALL CARPET T TLL &� INST'L BY T.G.C. SHOW WINDOW LANDLORD'S BULKHEAD DqB-orto4 FNISHED ENTRANCE ARCH SUP'L BY TENANT, INST'E BY T.G.C. HANGING LOW VOLTAGE PENDANT LIGHT FIXTURES. BOTTOM O 8' -0" A.F.F. SUPPLIED BY TENANT, INSTALLED BY T.E.C. FINISHED SHOW WINDOW ARCH SUP'L BY TENANT, INST'L BY T.G.C. PANTED CROWN MOULDING SUP BY F.C. & INST'L BY T.C.C. PANTED COLUMNS (TYPICAL ALL SIDES) PANTED MOULDINGS BY T.G.C. ROLLING GRILLE SUPPLIED & INSTALLED BY TENANT 1/2' THK. CLEAR PLATE TEMPERED GLASS SUP'L & INST'L BY T.G.C. 4 "H. SHOW WINDOW SIGNAGE SUP'L BY TENANT, INST'L BY T.G.C. ®FINISHED BASE SUP'L T.C.C BT TENANT, INST'L BY SHEETROCK C EILING 12' -O' A.F. BY T.G.C. ©QUARRY TILE SUP'L BY TENANT, INST'L BY T.G.C. ION rill — ___.. (! " T 1 I UII...i.11.k REE FlNISHED MOLDED BASE K" P'L BY TENANT, INST'L BY A., T.C.C. I/ T TEMP GLAS SUP & INST'L BY ERED T.C.CAS.— L ri A-- PA 3/' NON- COMBUSTABLE PLYWOOD ON 5 8" TH. TYPE "5 SHEETROCK T &S ON 3 -5 8 25 ga. METAL STUD E AS REVD.) SUP L & INST'L BY T.C.C. TOP OF CROWN MOULDING 8 7' -6' A.F.E. �©PAMFD COI LIMNS RY A E.G.. INST'L BY T.C.C. NON -COMB SOLID BLOCKING EG NON- & B ST'L T.C.C. LO IN G'0.) OE ROLLING GRILLE — =. r OOD FL RING TRANSITION STRIP 4-3/4" MARBLE PLAQUE, I' X 5' ( "ENGRAVE THIS EVENT') RO LANG GRILLE S PPORT POSTS & GRI LE SUP'L & I ST'LBY TENANT. • PANTED MOLDED BASE SUP'L BY TENANT, INST'L BY T.C.C. GI SUP'LL &INST'L EDEMCECRED SCALE' 1'=1' -0' • ID CARPET T.C.C. TO PATCH & REPAIR EXIST DEMISING PARTITION AS REVD & PREPARE TO RECEIVE NEW FINISHES. 1=I NYL WALLCOVERING SUP'L BY TENANT, INST'L BY T.G.C. (SEE INTERIOR ELEVATION D /F1) 1 SHEETROCK CEILING O 12 12' -0' -0" A.F.F. BY T.G.C. —� LINE OF SOFFIT ABOVE 1G' -4" A.F.F. BY T.O.C. — DA PAM SIDEWAL SUP'L & INST'L BY T.G.C. ['CERAMIC TILE "GRASS" STOREFRONT PLAN DETAIL SIGN PANEL / 'A LEASE LINE / -g QUARRY TILE SHOW WINDOW ROLLING GRILLE OPENING LEASE LINE TO LEASE LINE GENERAL CONSTRUCTION NOTES IALL EXPOSED MARBLE TILE EDGES ARE TO BE POLISHED. 1/2' TEMPERED PLATE GLASS SUPPLIED & INSTALLED BY T.C.C. BUTT -JOINT GAP SHALL NOT EXCEED 1/8' MAX. SEAL GLAZING WITH APPROVED GLAZING SEALANT TOP AND BOTTOM w/ POLISHED EDGES. (TYPICAL) I ALL WOOD CORNERS ARE TO BE MITERED. SIGN MANUFACTURER TO SUBMIT SIGN SHOP DRAWINGS I TO LANDLORD FOR APPROVAL I T.G.C. TO CONSTRUCT A STOREFRONT BARRICADE AS PER I LANDLORD CRITERIA. ALL GLAZING WORK SHALL BE PERFORMED IN ACCORDANCE WITH "CODE DE FEDERAL REGULATIONS - COMMERCIAL PRAC- TICED - -SUB- CHAPTER B OF CONSUMER PRODUCT SAFETY ACT REGULATIONS' PART 1201 "SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS" STOREFRONT MUST BE TOTALLY SELF SUPPORTING. T.G.C. TO PROVIDE NONCOMBUSTIBLE BEAM TO SUPPORT STOREFRONT CONSTRUCTION IF REQUIRED. ANY ATTACHMENT TO DEMISING WALLS, FREIZE BOARD CONSTRUCTION OR ROOF STRUCTURE SHALL BE FOR LATERAL STABILITY ONLY. DO NOT SUPPORT FROM LANDLORD'S SOFFIT, ROOF FRAME OR COLUMNS. T.C.C. TO SUPPLY & INSTALL CRL AMC - 180 CLEAR ACRYLIC, SQUARE GLASS CUPS 0 STOREFRONT SHOW WINDOW GLAZING BUTT JOINTS. CITY (I (LECQILA AIY'HG'J(N ALL& 2J 00 0 m 8 0 a L5 y„ U 2 CffY"� DRAWNNG N0. ARIA B 5 1510 PERMITCEIRER 98107 -A2 COLOR & FINISH SCHEDULE CODE MATERIAL DESCRIPTION & SPECIFICATIONS ❑A PNNT QUINSTONE INDUSTRIES — CUSTOM COLOR PAINT SHERWIN WILLIAMS #SW1183 — "PLAZA SUITE' (EGG SHELL) E PANT SHERWIN WILLIAMS #SW1354 — 'WHITE WOOL' (GLOSS) E HIPLAM PIONRE #AV731 -6 SUEDE 'CELEDON IMPRESSION" E VINYL J.M. LYNNE #DVW4523 — "OVERTURE' © VINYL J.M. LYNNE #2401 —SN — 'SIENA SEASHELL" E TILE 12" X 12" "KASIIMIR CRAPRA' QUARRY TILE E TILE 16" X 16" IMAGE CERAMIC TILE #8050 "GRASS" E W OOD PERGO SKU #PF4000 -1 'OAK" ❑K CARPET MANNINGTON COMMERCIAL CARPET #CARTHNEE -28 "NAUTICA" DIAGONAL BRACING USING 3 5/8" 16 9o. METAL STUDS 48" 0, SUP L & INST'L BY T.G.C RECESSED HI HAT LIGHT FIXTURE SUP'L BY TENANT, INSTALLED BY T.E.C. SALES AREA SHEETROCK CL'G SUP'L & INST'L BY T.C.C. 0 12' -0" AFF. 5/8' TYPE "X" SHEETROCK (T &S) ON 3 5/8" 20 ga. METAL STUDS. (FRAME AS REO'D.) SUP'L & INST'L BY T.G.C. SALES AREA LAY —IN '•••••• CL'S SUFI. & INST'L BY T.G.C. ® 10' -6" A.F.F. DE VINYL WALLCOVERING SUP'L BY F.C.. INTEL BY T.G.C. NON -COMB. WOOD BLOCKLIN AS REQUIRED BY T.C.C. DA PANT UNDERSIDE OF A S UP'L & INST'L BY T.G.C. RCH METAL GLAZING CHARNEL SUP'L & NST'L HANGING LOW VOLTAGE PENDANT LIGHT FIXTURE SUP'L BY TENANT. / IC INSYL BY T.G.C. BOTTOM OF LIGHT O B' -0' A.F.F. QB PANTED W000 CROWN M OULDING SUP'L & INST'L BY T.C. 1/2' TH EA PLATE TEMPERED GLASS SU P'L CLR & INST'L BY T.C.C. LEASE LINE EXIST'S NEUTRAL PIER ▪ PAINTED COLUMN (TYPICAL ALL SIDES) BY T.G.C. E PANTED 3/4" W000 MOULDING SUP'L & INST BY T.C.C. (TYP. ALL SIDES.) (FINISHED MOLDED BASE 6' H. SUP'L BY TENANT. INST'L BY T.G.C. (TYP. BOTH SIDES.) DK CARPET SUPPLIED & INSTALLED BY TENANT 2 d" / / SECTION THRU SHOW WINDOW EXISTING k- LANDLORD BULKHEAD L — 1 ENTF CL'G 2 27 OFA I AREA SHEETROCK SUP'L k INST'L BY 0 11', 1/2" A.F.F. IED MOLDED STONE SUP'L NANT. INST'L SY T.G.C.. IED SHOW WINDOW ARCH SUP'L NANT, INST'L BY T.C.C. D*oz�4 EXISTING LANKLORO BULKHEAD EXISTING LANDLORD PROJECTION DA FINISHED KEYSTONE GAOL BO TENANT, INSFL BY TG.L. DA FINISHED E RIRANCE AR SUP'L BY TENAN INST'L BY T .G.C. SIGN PANEL SUP'L BY TENANT. INSTALLED BY T.C.C. LEASE LINE EXIST'G NEUTRAL PIER © PANTED COLUMN (TYPICAL ALL SIDES) BY T.G.C. DB AINT 3ED W000 MOULTING SUP'L & 3/4 I S1'L BY T.C.C. (ttP. ALL SIDES.) (( FINISHED MOLDED BASE 6' H. SUP'L BY TENANT. INSYL BY T.G.C. (TYP. BOTH SIDES.) EXISTING CONCRETE SLAB TO REMAIN J 5/8" TYPE "X" SHEETROCK (T &S) ON 3 5/8' 20 ga. METAL STUDS. (FRAME AS REVD.) SUP'L & INST'L BY T.G.C. I r • SECTION THRU GRILLE OPENING SELF S ROLLING GRILLE ASSEMBLY SUP'L & INST'L BY TENANT. DIAL NAL BRACING USING 3 5 /B" 16 9a. METAL STUDS 48" o.c. SUP L & INST'L BY T.C.C. RECESSED HI HAT LIGHT FIXTURE SUP'L BY TENANT, INST'L BY T.E.C. SHEETROCK CEILING SUPPLIED & INSTALLED BY T.G.C. 0 12' -0" GRILLE POST BEYOND TO EXTEND TO & BE BRACED TO STRUCTURE ABOVE FOR LATERAL SUPPORT ONLY. (DO NOT WELD) -SALES AREA LAY -IN CL'G SUPPLIED & INSTALLED BY T.G.C, 0 10' -8" A.F.F. DE VINYL WALLCOVERING UP BY TENANT, INST'L BV S T. QB PAINTED WOOD CROWN MOULDING SUP'L & INST'L BY T.C.C. CENTERLINE OF ROLLING GRILLE LINE OF ROLLING GRILLE GUIDE QK CARPET SUPPLIED & INSTALLED BY TENANT GENERAL CONSTRUCTION NOTES [ALL EXPOSED MARBLE TILE EDGES ARE TO BE POLISHED. 1/2" TEMPERED PLATE GLASS SUPPLIED & INSTALLED BY T.G.C. BUTT —JOINT GAP SHALL NOT EXCEED 1/8" MAX. SEAL GLAZING WITH APPROVED GLAZING SEALANT TOP AND BOTTOM w/ POLISHED EDGES. (TYPICAL) [ALL WOOD CORNERS ARE TO BE MITERED. SIGN MANUFACTURER TO SUBMIT SIGN SHOP DRAWINGS TO LANDLORD FOR APPROVAL 1 T .G.C. TO CONSTRUCT A STOREFRONT BARRICADE AS PER LANDLORD CRITERIA. ALL GLAZING WORK SHALL BE PERFORMED IN ACCORDANCE WITH CODE OF FEDERAL REGULATIONS- COMMERCAL PRAC- TICES-I6- SUB - CHAPTER B OF CONSUMER PRODUCT SAFETY ACT REGULATIONS" PART 1201 "SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS' STOREFRONT MUST BE TOTALLY SELF SUPPORRNG. T.G.C. TO PROVIDE NONCOMBUSTIBLE BEAM TO SUPPORT STOREFRONT CONSTRUCTION IF REQUIRED. ANY ATTACHMENT TO DEMISING WALLS, FROZE BOARD CONSTRUCTION OR ROOF STRUCTURE SHALL BE FOR LATERAL STABILITY ONLY. DO NOT SUPPORT FROM LANDLORD'S SOFFIT. ROOF FRAME OR COLUMNS. WY UP NiUSW. M'L AUG 2 5 1T)3 U � W� N I& U " 0 Qo (0 0 LL Q N CL W U or J • , • N W N W Q O N N Y Ya a i + U o f C 0 2 w g ' z p E E [ m ' V, 0 O 0 m � 2 m "0 C> A- w Q O 2 Q O Z he G pBo g ,.dig DRAW°'G MO .cuL G 3 1998 ftrIETS COLOR & FINISH ON & SPECIFICATIONS pA PLANT QUINSTONE INDUSTRIES - CUSTOM COLOR PLANT SHERWIN WILUAMS BSW I 155- "CHAPEL STONE" (EGO SHELL) PONT SHERWIN WILLIAMS #SWI354 -'MITE WOOL" (EGG SHELL) E HIPWA FORMICA #721 - "DESERT RAWHIDE" ❑E win_ J.M. LYNNE #0N64523 - "OVERTURE" OF VI NYL J.M. LYNNE #2401-SN - "SIENA SEASHELL" ❑O TILE 1 2" X 12" "KASHMIR CRAPRA" QUARRY TILE O TILE 18" X 18" "CRASS" TILE IMAGE CERAMIC TILE ❑J WOOD PERGO SKUBPF4000 -1 - " ON( " CARPET QUEEN CARPET BAITOWNE 30 - "SHAW( TEAL" #203 r ob . ... ■ •111■7 ®C411111111•1111111I l ool E ICI °0�s_ �__I 1�- J -" F c1 ELEVATiON SCALE: 1/4 " =1' -O" SCALE: 1/4 " =I " -0" ELEVATION SCALE 1/4 "=1' -0" 4 . -0 . BASE BAS SALES AREA SHEETROCK CEILING BY T.C.C. O 12' -0" A.F F. WALL MOUNTED RIBBON BOARD AND SIGNAGE BOWS SUP'L BY TENANT & INST'L BY T.G.C. SALES AREA LAY -IN CEILING SUP'L & INST'L BY T.C.C. O 10' - 8" A.F.F. PREFINISHE BOARD & BATTENS w/ STANDARD BRACKETS & SHELVES SUP'L BY F.C., INST'L BY T.G.C. STACK TABLES STACK TABLES LINE OF TOILET ROOM DECK AT B' -0" A.F.F. • MP MP ■ ■': Mai L BOX 40" X 30" L IGHT BO 40" Y. 30 7©C- S %Mr I Aft WALL MOUNTED RIBBON BOARD AND SIGNAGE BOWS SUP'L BY TENANT & INST'L BY T.G.C n ._ g rp III p■ 7 ►� ail ... 1 art VIP I .Il LEI i N •=1■111=1f LINE OF 1/2" TEMPERED GLASS SHOW WINDOW E I INE CENTERLINE OF sip TOP OF MOULDING t v- iii■ 1VI 5'I1� - • STACK TABLES STACK TABLES BASE DISPLAY TABLE ler ;\I KEY I 8080 36" 30" A .F.F. Ts PLAY BLE IIIIIKIEZEUEI ENE SALES AREA - CARPET FLOORING E - WOOD BASE - LAY -IN CEILING 0 10' - B" OFF. STACK TABLES 3/4 DW'* 36" A.F. Fl. 3 I n 42" ETAGERE BASE 0 e 54" ETAGERE ( 0 0 "�TU � BASE BAS FIXTURE FLOOR PLAN BASE SERVICE ISLAND - CARPET FLOORING KE - LAY -IN CEILING AT B' -6" A.F.F L�J � - VINYL WALLS BASE / BASE / / BASE / BASE BASE STOCKROOM CEILING SUP'L & INSTALLED BY T.G.C. O 12' -0" OF.F. -WALL MOUNTED WALL SCONCE SUP'L.BY TENANT, INST. BY T.E.C. LOCATION OF ELECTRIC PANEL AND GEAR REFER TO DWG. El & E2 SCARCE ISLAND CEILING SUP'L & INST'L BY T.G.C. SERVICE IS FIXTURES SUP'L BY F. C . , INST'L BY T.C.C. BASE BASE BASE BASE / 4 r r- A NEW HANDICAPPED TOILET ROOM - V.C. TILE FLOOR - SHEETROCK CEILING AT 1' -6" AF.F. - 4" VINYL BASE TYP. ALL WALLS) -C -ICJYAINT ALL WALLS ELEVATION SCALE: 1/4 " ..1' -0" TOP OF MO ® ]' -fi" A.F.F. ROLLING GRILLE SUP'L & INSTALLED BY TENANT ELEVATION FS SCALE: 1/4 • =1' -0" F ILLER FACE PANEL SUP'L BY F.C., INST'L BY T.G.C. -SALES AREA LAY -IN CEILING SUPPLIED & INSTALLED O 10' -6" A.F.F. BY T.G.C. BASE CABINETS UP'L BY F.C., INST'L BY T G.C. 4 "h. MAPLE BASE UP'L BY F.C., INSYL BY T.G.C. SALES AREA SHEETROCK CEILING SUP'L & INSYL O 10' -8" A.F.F. BY T.G.C. T.G.C. TO SUP'L AND INST'L CLEAR PLASRC CORNER GUARDS ON ALL COLUMN EDGES & EXPOSED CORNERS (WHEN APPLICABLE. T.G.C. TO INSTALL FLOOR MERCHANDISERS IN SUCH A I WAY AS TO MAINTAIN A 36" CLEAR ACCESS. 4" HIGH MAPLE BASE IS SUP'L BY FC INST'L BY T.G.C. ON FACE OF BUILT -IN BASE & ON ALL EXPOSED WALL AREAS. NOTE - RIBBONS & BOWS SUP'L & INST'L BY F.C. . 55 BOW RIBBON DET SCALE: 1/2 " =1' -O" O Li E 3 N z J 1 / .3 ao ceZ 0 oad DRAWING 1041 1 3 1 11) 1 98 GIN OF Tfll(4YIU Al'PRO','i 0 AUG 2 5 1023 RIBBON RIBBON(S) BOW(S) • ® ®mp„-miri-- -----� - -1- 01111111111111111111111111111 MEEE " 1111111.1•111111111111111 I mm I■ M►1 ' © E N 'E�■��■■ _. -■'—t w 111111109111101® 11 �► 1 1i11 1 111 1 1111111411 1 1 imarair_proom \ GRID L -20 OF STORE ry \ 3 . _� r L L -2 L 23 L-4 \ T.G.C. TO CHANNEL SLAP. FOR INSTALLATION OF 3/4" CONDUIT BY T.E.C. 1 / BY T.E.C. TYPICAL FLOOR RECEPTL'S CL OF COLUMN L -19 \ 1 11 r -- - -I L -17 1 1 1-24 L -10 L -12 TI - - -`I , - - - - - 1 — I L-- - *� ---- T - L -19 ON A I // JUNCTION BOX FOR WALL SCONCE, INSTALL CLOCK RECEPT L BY T.E.C. MOUNTED AT 8' -0" A.F.F. FOR LIGHT BOX L -2 T.G.C. TO CHANNEL SLAB FOR INSTALLATION OF /4' CONDUIT BY T.E.C. / p na ICI :1 1-- p —_!I I 7 -- T - ri - ` \ - EAR DOOR BELL ABOVE CEILING L -19 1-17 ■ L \, Y -23 4 _L -28 1 -23 L -22 1-26 DUPLEX RECEPTACLE MOUNTED IN SHEETROCK SOFT1T SUP'L. & IN511 BY T.E.C. L -13 L -27 JUNCTION BOX W/ DISCONNECT SWRCH BY T.E.C. LOCATE AS REQUIRED FOR SIGN 1-13 DUPLEX RECEPTACLE MOUNTED IN SHEETROCK SOFFIT SUP'L. & INST. BY T.E.C. L -11 REFLECTED CEILING PLAN SCALE: 1/4 " =1' -0" SCALE: 1/4' =1 -0 L -8 L -14 CLOCK RECEPTACLES MOUNTED 0 6' -0" A.F.F. FOR LIGHT BOXES. VERIFY EXACT LOCATION W/ THINGS REMEMBERED. POWER WIRING PLAN NEW 4 WAY BLOW BIFFUSER W/ WHITE BAKED ENAMEL FINISH 300 CFM EA., 12' X 12' LINE OF HEETROCK SOFFIT 0 TYPICAL SPEAKER SUPPLIED AND INSTALLED BY T.G.C. BY T.E.C. Dqs--07.(04 SALES AREA C 2',(2 SL E WHITE 14 N L ING TILES ON DONN 15/16' WHITE TEE GRID SYSTEM SUPPLIED & INSTALLED BY T.G.C. 0 10' -6" AFF SERVICE ISLAND SERVICE ISLAND CEILING TO BE U.S.G. #893 SANDRIFT CLIMAPLUS 2'x213/4" SL WHITE LAY -IN CEILING TILES ON DONN 15/16" WHITE TEE GRID SYSTEM °JPPLIED AND INSTALLED BY T,G.C. AT 8' -0" A.F.F. 1-8 -8 T.E.C. TO PROVDE JB ABOVE CEILING. FEED DOWN WALL & STUB 0 2' A.F.F. L -16 FOR BACK BAR RECEPTACLES. PLUOMOLO SUP'L BY TENANT, INSYL BY T.E.C. 0 37' A.F.F. TO CENTERLINE. L -15 46 • G.F.I. RECEPT. 0 42' 4110. NEW 4 WAY BLOW DIFFUSER W/ WHITE BAKED ENAMEL FINISH 150 CFM EA, 8' X 8' STOCKROOM CEILING TO BE ARMSTRONG 2'x4' WHITE lAY -IN CEILNG TILES ON EXPOSED WHITE SUSPENSION GRID. SUPPLIED & INSTALLED BY T.G.C. AT 12' -0" A.F.F. SPRINKLER NOTES ALL MODIFICATIONS, ADDITIONS, REPAIRS, OR RELOCATIONS TO THE SPRINKLER SYSTEM REQUIRED FOR THE TENANT'S USE SHALL BE PERFORMED BY THE T.C.C. T.G.C. SHALL SUPPLY LANDLORD WITH (2) COPIES OF THE SPRINKLER SHOP DRAWINGS PRIOR TO INSTALLATION OF TENANT'S SPRINKLER SYSTEM. SPRINKLER CONTRACTOR & SPRINKLER DRAWINGS MUST BE APPROVED BY LANDLORD PRIOR TO START OF SPRINKLER WORK. SPRINKLER HEAD IN LOWER CEILING 0 TOILET ROOM HANDICAPPED TOILET ROOM CEILING TO BE 5/8" TYPE 'X' SHEETROCK (T&S) 0 7' -8- A.F.F. w/ PLYWOOD DECK ABOVE 0 8 -0' AF.F. SUPPLIED & INSTALLED BY T.G.C. 4 — REAR DOOR BELL PUSH BUTTON SUP'L AND INST. BY T.E.C. AT 48" A.F.F. ECEPT'L FOR MUSIC SYSTEM SUP'L AND INST. BY T.E.C. AT 12' AF.0. , EMERGENCY BATTERY U1 SUPPLIED BY TENANT, INSTALLED 6Y T.E.C. 0 9 -0" A.F.F. COMBINATION TOILET ROOM LIGHT & EXHAUST FAN SUPPLJED BY TENANT, INSTALLED BY T.E.C. G.F.I. RECEPT. 0 12' AF.F. FOR INSTANT HOT WATER 0 Q i cn W 02 0 Z Q Z fig z J oz 0- W < F W W� W 01 - 1J3 r3 WO o KC urt F g o G " 5OP TVE WIIA ORAWNIG N0. FUa U S 1'0 PERNTOEHfm 98107 -E1 ELECTRICAL LEGEND SYMBOL DESCRIPTION FURN. INST. DUPLEX RECEPTACLE • 180 WATTS A=12° A 14 EC AFF (MOUNT HORIZ) C =38" AFF TEC TEC IN CASEWOR< ENG/WAVERP(ISOLATED GGROUND) 1000 WATTS FC TEC Q DUPLEX RECEPTACLE IN CASEWORK 180 WATTS FC TEC G . F .I. GROUND - FAULT INTCPTOR DUPLEX RECEPTACLE MEROEUNTED AT 42" A.F.F. 180 WATTS TEC TEC DEDICATED CPTA CLE - HUBBELL #IG5251 SEPERATE NE AND GROUND (IN CASE WORK) 180 WATTS FC TEC #2000 PLUGMOLD STRIP (Mr D ON TOP OF BACK BAR SPLASH) TENANT TEC O FLOOR MW43 BOX 2 AND W /DUP■TCPLEX 2 RECEPTACLE LEER TENANT TEC A JUE 60P gq T A R / C 2 FL /HIR 1 HOUSING 200 AN D LIM28P C -WH TRIM WTH (1) 60 WATTS G TENANT TEC • B JUNG pT HOUS GE 60PR / F L /HIR 120 LAMING AND 260 - WH TRIM WRH (1) 60 WATTS TENANT OFT C JUNG 0PM36/H #qT543WH /WASPS HOUSING AND T446WH TRIM WITH (T) 50 W GE 5 TENANT TEC D JUNG 50 ppTC917 6 /C HO /CG /SP USING 15 AND 444W -WH TRIM WITH (1) 50 WATTS GE G MR1 TENANT TEC ® LIGHTOLIER 31 35 DAPHNE SERIES. POLISHED 40 WATTS BRASS W/ RASTER SHADE. INSTALL 6' OF.F. TENANT TEC LIGHTOLIER #STG240R SHPFI2OSO GAR D 70 WATTS STRIP FLUO / pESCENT ( 24 ", 36 ") w/ F32T8/S P35 TENANT TEC I- - - / " ( MID STAG ( 4 5 8 jffitr OWEA PACK *L(I) CA /SP15 IWMP 50 WATTS TENANT TEC L V O 7 JUNG - ACKMASTE 1 w/ 430 -WH TRACK WMPH T HEAD 50 WATTS ALAD GE SPAS T TENANT TEC H 9 Q Q JUNG TPTCNMRAIE TRACK AR R : 50 WATTS µp1 CE OAR TA R SION BR w/ WAT228 -XED AN TACK HEAD D TCC TENANT TEC 1 1 } DPA TSGBWH ORMER & / GE OSDMRI6 /C /CC /SPAS LAMP WATTS TENANT TEC MII i UG w/ GE F4 HTOUER 0 X /SPX41 NOVSZGPF052 U4120SB RECESSED TROFFER TENANT TEC K T T538 -WH / GE 050 R1S /CC /CG /SP15 TENANT TEC PA T I00A /9 O WEM 6 1200LILAMCF 0 CCFM, 40 6NE5 100 WATTS TENANT TEC SELF POWERED LED EXIT SIGN TENANT TEC SELF POWERED EMERGENCY FLOOD TENANT TEC JB JUNCTION BOX TEC TEC JB JUNCTION BOX FO R STOREFRONT LIT SIGN WITH DISCONNEC SWITCH TEC TEC L INTERMA 9X1471 BR TIME CLOCK FOR STORE TIC OAT SIGN AND SHOW WINDOW LIGHTS T T ENAN TEC ® REAR DOOR PUSH BUTTON AT 4' -O" A.F.F. TEC TEC p , pJ REAR DOOR BELL 1i I'D ABOVE SALES AREA CEILING TEC TEC • TELEPHONE JACK TEC TEC JB PROGR FIXTESS UE. # ? 5846 -11 WEATHERED SOLID BRASS CARRIAGE LIGHT TENANT TEC PLUMBING FIXTURE SCHEDULE T.P.C. TO SUPPLY & INSTALL ITEMS #4 -7, HANDICAPPED TOILET FIXTURES 8: RELATED ITEMS. TENANT TO SUPPLY ITEMS # -3 ; T.P.C. TO INSTALL ITEMS. 1. SURFACE MOUNTED WALL MIRROR 18 "x24" - BRADLEY #700- 18x24. 2. SURFACE MOUNTED SINGLE ROLL TOILET PAPER DISPENSER - BRADLEY #5054. 3. SURFACE MOUNTED ROLL PAPER TOWEL DISPENSER - BRADLEY #2481 -11. 4. INSTANT WATER HEATER "ARISTON" #P105 1200 WATTS 120 V 10 5. 3" FLOOR DRAIN JR SMITH #2010 -A w/ NICKLE FINISH 6. CLEANOUT - JR SMITH 4000 SERIES w/ NICKLE FINISH 7. HANDICAP FIXTUES: A. WATER CLOSET - AMERICAN STANDARD #SPS 2168 "CADET" 17 "H EL 1.6 /PA, VITREOUS CHINA, LOW CONSUMPTION, ELONGATED BOWL. B. LAVATORY - AMERICAN STANDARD #SAS 0124 "COMRADE" WALL HUNG, VITREOUS CHINA W/ 7490 -172H AMARILIS FAUCET W j WRIST BLADE HANDLES. C. GRAB BARS - BRADLEY #800 SERIES WITH ACCESSORIES. NOTE: ALL SINKS MEET NSF STANDARDS. NOTE: T.P.C. TO SEE THAT INSTALLATION OF THE ABOVE TOILET ROOM FIXTURES AND ACCESSORIES MEETS ALL GOVERNING CODES. NOTE: T.P.C. TO PROVIDE AIR CHAMBERS & STOP VALVES AT EACH FIXTURE M1' UP•LY TO BE COPPER W/ INSULATION. CONNECT TO EXIST'G MAIN CW SUPPLY LINE. FIELD VERIFY EXACT POINT OF CONNECTION 4" WASTE LINE. SOIL & WASTE PIPING TO BE CAST IRON. CONNECT TO EXIST'G MAIN WASTE LINE. FIELD VERIFY EXACT POINT OF CONNECTION. VENT PIPING TO BE CAST IRON, GALVANIZED STEEL OR COPPER. PVC NOT ALLOWED WATER METER. INSTALL 12" A.F.F METER SHALL READ IN GALLONS. SCALE: I/4 " =1' -0" PLUMBING FLOOR PLAN SCALE: 1/4' =1' -0" SCALE: 1/4 " =1' -0' 1-1/2" DOMESTIC WATER RISER DIAGRAM I 2" 2' VENT, CONNECT TO EXISTING MAN VENT LINE. FIELD VERIFY EXACT POINT OF CONNECTION. WASTE & VENT RISER DIAGRAM ) ELECTRICAL NOTES t. ELECTRIC METER, IF REO'O, TO BE SUP'L AND INSYL BY T.E.C. (UNLESS OTHERWISE NOTED.) 2. ALL ELECTRIC GEM WITHIN TENANT SPACE (PANEL BOARD, TRANSFORMER, SWITCHES. ETC...) ARE SUP'L BY OWNER, INST'L BY T.E.C. 3. ALL SALES WALL RECEPTACLES TO BE WHTE WOK WHITE COVER PLATES. 4. ALL SAFETY SWITCH DISCONNECTS FOR HMG ROOF TOP ANTS, WHERE REO'D BY LOCAL CODE ARE SUP'L AND INST'L BY F.E.C. 5. T.E.C. TO PROVIDE A REM DOOR BUZZER AT 4' -0" A.F.F. AND DOOR BELL INST'L AS SHOWN ON SHEET 'E1' (WHEN SERVICE DOOR APPLIES.) 6. PERMANENT INTERIOR THONE WIRING, INCLUDING 3/4" E.M.T. AND A MINIMUM OF (4) TWISTED PAIR OF PHONE WIRE IS SUP'" AND INSYL BY T.E.C. 7. ALL ELECTRICAL WITHIN CASH/WRAP IS SUP'L BY F.C., HOOK -UP BY T.E.C. 8. ALL ELECTRICAL WORK AND INSTALLATION TO BE DONE IN A GOOD WORK - MANLIKE MANNER AND SHALL CONFORM TO ALL NATIONAL UNDERWRITERS. STATE AND LOCAL CODES WHERE MPUCABLE. 9. ALL MATERIALS & EQUIPMENT SUBSTITUTED AS "EQUAL" MUST HAVE WRITTEN APPROVAL BY THINGS REMEMBERED BEFORE INSTALLATION. 10. NO ROMEO, IX, ETC. IS TO BE USED. 11. T.E.C. TO INST'L EMERGENCY LIGHTING AND EXIT LIGHTS WITH SECONDARY POWER SOURCE, CONNECTED TO EMERGENCY BATTERY UNIT. 12. IDENTIFY ALL EQUIPMENT AND APPARATUS WITH ENGRAVED &J(ELTTE NAMEPLATE OR IMPRESSED, PLASTIC NAME STRIP. . 13. FURNISH A TYPEWRRTEN CIRCUIT DIRECTORY CARD IN ALL UGHRNG AND POWER PANELS. 14. ALL BRANCH WIRING, DEVICES, LIGHTING FIXTURES, CONDUITS, EQUIP- MENT, ETC., SHALL BE GROUNDED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. PROVIDE A COMPLETE EQUIPMENT AND SERVICE GROUNDING SYSTEM. 15. THE CONTRACTOR SHALL COORDINATE MD VERIFY THE ELECTRICAL CHARACTERISTICS, REQUIREMENTS AND LOCATION OR HEATING EQUIP- MENT BEFORE ORDERING AND INSTALUNG ANY SERVICE FOR SAME INDICATED ON ME DRAWINGS. 16. ALL CONDVR SHALL BE RUN CONCEALED IN FINISHED AREAS. ALL CON- DOR UNDER GROUND OR IN CONCRETE SLAB SHALL BE RIGID CONDUIT. ALL OTHER CONDUIT MAY BE THIN WALL ALL OUTLETS SHALL BE FLUSH MOUNTED. ALL CONDUITS SHALL BE RUN PARALLEL WITH AND AT RIGHT ANGLES TO THE BUILDING CONSTRUCTION AND SHALL BE LEVEL 17. GRIT ENGRAVER RECEPTACLE TO BE ISOLATED AND GROUNDED. 18. ALL TELEPHONE ROUGH -IN WIRING AND JACKS TO BE PROVIDED BY T.E.C., FINAL CONNECTION BY TELEPHONE CO./TENANT. 19. P.O.S. REGISTER PHONE JACKS BY TELEPHONE CO./TENANT. 20. T.E.C. SHALL BE RESPONSIBLE FOR REMOVING EXISTING FLUOR- ESCENT LIGHT FIXTURE LENSES SUPPUED WITH FIXTURES AND INSTALL NEW OWNER SUPPLIED 1 1/2 "x1 1/2' LOUVERS. 21. T.E.C. TO PROVIDE FEED FOR FEATURE CASE UGHTNG AT 7' -8" OF,F. LU 100 PAP S.5. ELECTRICAL SERVICE DIAGRAM LANDLORD "LANDLORD'S DISTRIBUTION PANEL TENANT SPACE NEW 120 /2080 'L' PANEL LC.B, 100A 42 CIRC NEW 4 #2 R: ILO!' THAN 1 1 C. BY ALL PANELS TO HAVE BOLT -ON CIRCUIT BREAKERS. ELECTRICAL DATA TABULATION LOAD TYPE PER NEC CONNECTED KW LIGHDNG 5.6 RECEPTACLE 4.7 AIR CONDITIONING WATER HEATING 8.1 1.4 APPLIANCES SIGN 0.8 TOTAL LOAD 21.5 DEMAND FACTOR 125% 100% 100% 100% 100% 125% SUB TOTAL TOTAL LOAD DEMAND KW 7.0 4.7 CONDUCTORS 4 #2 FUSES 100 AMP 8.1 1.4 0.8 23.1 SEE BELOW SERVICE REQUIREMENTS CONDUIT 1 1/4' SWITCH 100 AMP 11 13 15 17 19 21 23 25 27 29 33 35 10 PANEL USE AND /OR AREA SERVED UGHTS- TRACK LIGHTS- TRACK LIGHTS- TRACK MFRS- TRACK UGHTS- SERACE ISLAND LIGHTS- DOWNUGHTS DORIS- WINDOW @ CMROGE LIGHTS- STAGGAR) STRIPS DORIS- STAGGARO SIRES LIGHTS- FEATURE AREAS UGHTS- STOCK ROOM LIGHTS- EXITS, NL & BATTERY LTG/HS-262 RUORESCENTS SIGN SPARE TOTAL LOAD PER PHASE 10,000 WIC BREAKER MINIMU MOUNTING: SURFACE I VOLTAGE. 120/20BV 34 I MAINS: 100A MCB 6 CIR C/B TT' USE AND /OR AREA SEAMED AX 1 500 60 2 2 RECEPTACLE-SOFT!, 3 , 2 RECEPTACLE- FLOOR C/B CIR 360 L 250 360 660 330 60 400 540 360 360 360 9,217 9,735 9,295 fi B 2 10 2 2 I 20 22 24 20 2 7 360 600 1100 TOTAL WATTS - 28 217 4. 20% w 33,880W w 94 RAPS RECEPTACLE- WALL RECEPTACLE- WALL RECEPTACLE- ENGRAVER @ CRT RECEPTACLE- ENGRAVER @ CRT RECEPTACLE- PLUGMOLD RECEPTACLE - SERVICE SAND RECEPTACLES -CASH REGISTER 2x2 fJIO ESLFMS WATER HEATER BAGMAN. DISPLAY TOILET LIGHT, FAN, RECEPTL 28 30 32 34 36 42 r 3 STOCKROOM RECEPD'S EXISTING AIR HANDLER EXISTING DUCT HEATER EXISTING HEAT PUMP • w CONNECT TO TIME CLOCK A = LOCKBREAKER INSTALLED EXISTING HVAC THE EXISTING 'CARRIER' #38TK3042310 HEAT PUMP (208/1/60) WITH ELECTRIC DUCT HEATER TO BE ECONDITIONED AND EUSED. THE MECHANICAL CONTRACTOR SHALL FIELD VERIFY THE CONDITION OF THE EXISTING HVAC SYSTEM THAT SUCH SYSTEM IS FULLY OPERABLE AND IN CONFORMANCE WITH THE LANDLORDS REQUIREMENTS. THIS CONTRACTOR SHALL INCLUDE IN HIS BID THE COST TO REPAIR, UPGRADE OR REPLACE SAME. CONRACTOR SHALL PROVIDE WRITTEN CONFIRMATION TO THE TENANT THAT THE EXISTING HVAC SYSTEM IS FULLY OPERABLE AND WILL MAINTAIN HEATING AND COOUNG TEMPERATUES WITHIN THE LEASED SPACE IN ACCORDANCE WITH THE LANDLORDS REOUIEMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING NEW FLEX DUCT CONNECTIONS, NEW DIFFUSERS AND NEW RETURN AIR GRILLES. CO 5 N C 0 U LIRAMWNNG(##S/ 0 3 1999 98 OO P2 A A A A LU COLOR & FINISH SCHEDULE CODE MATERIAL DESCRIPTION & SPECIFICATIONS ❑A HIPLAM FORMICA #921 "BIRCH [B HIPLAM FORMICA #923 "SURF" 5 /B" TYPE "X' SETROCK (T &5. SIDES ON 3 5/ 8' TA. i69a. METAL HE STUDS O i6 H.H. BOTH SHEETROCK TO RUN FROM CONCRETE SLAB TO 12 -6' A FT. SUPPLIED & INSTALLED BY T -C.C. PAINT SHERWIN WILLIAMS #SW 1093 - "BEIGE SAND" ❑0 PAINT SHERWIN WILLIAMS #SW 1053 - "LIGHT MOVES' QE TILE VERONA MARBLE #80136 "BOTTICINO CLASSICO' © © ❑H Q TiLE GROUT VINYL CARPET BASE PAINT MAPEI MI5 "BONE' J.M. LYNNE #LT -5447 - "LYNLITE" SHAW #38191 'RIVULET" -- SHERWIN WILLIAMS MSW101D 'CRUSHED ICE' INSTA LLED B PP Y INSTAY T.G.C. _ _ _ =_NO FLAILS✓_ pe WALL SCHEDULE WALL SYMBOL WALL TYPE DESCRIPTION VARIES A O EXISTING DEMISNG WL EM T.G.C. O P REPAIR AS REQU AL R TO EADY R FOR AIN. NEW FINISTHESATCH & . T.G.C. TO ENSURE SHEETROCK IS SEALED TIGHT TO DECK ABOVE. B 5 /B" TYPE "X' SETROCK (T &5. SIDES ON 3 5/ 8' TA. i69a. METAL HE STUDS O i6 H.H. BOTH SHEETROCK TO RUN FROM CONCRETE SLAB TO 12 -6' A FT. SUPPLIED & INSTALLED BY T -C.C. 4 " u,,, H unu . C 5 /8" TH. TYPE "X" SHEETROCK (TWO) ON ONE SIDE OF 3 -5 /B" METAL STUD FRAMING. RUN SHEETROCK FROM CONCRETE SLAB TO 10' -B" A.F.F. BY T.C.C. 4 7/8" TX, O EXISTING 5/8" TH. TYPE "X" SHEETROCK (T &5). T.G.C. TO PATCH & REPAIR PARTITIONS READY FOR NEW FINISHES. '0 3 S A l ELEVATION SCALE: 1/4' =1' -0' POP - OUT 5'12'Ii T NO FINISH I 3' -I0�' J 4' - 3�• BUILT -IN BASE NO BASE 00 PAINT TOILET RM. & STOCK- ROOM WALLS BY T.G.C. — STOCKROOM LAY -IN CEILING SUPPLIED & INSTALLED 0 AFT BY T.G.C. 4 H. VINTL WALL BASE SUPPLIED & L ST'L BY T.G.C ELEVATION SCALE: 1/4'=1' -0' 3 -IDS' IL -IN HAS 0 BASE P E A WAL - 31' NO BASE NO FINISH L SOREFRONFFIT AT INE 9' OF -10 " A.FF BT Y TG LINE OF MOULDING ABOVE 0 8' -6' A F F. BY i C C CENTER ROLLING LINE GRILLE MALL TILE FLOOR SUP'L. & INST'L BY T.G.C. FROM LEASE LINE TO BACKSIDE OF COLUMN. 'MOHAVE' OUARRY CAST 6' H. MOLDED BASE SUP'L & INST'L BY T.G.C. —{]G VINYL WALLCOVERING ENTIRE WALL (U.N. O.) SUP'L BY TENANT. INST L BY T.G.C. BUILT -IN BASE BUILT -IN BASE SALES AREA LAY -IN CEILING SUP'I. & INST'L. BY T.G.C. 0 10' -0' A F.F. SALES AREA LAY -IN CEILING SUP'L & INST'L BY T.C.C. ['VINYL WALLCOVERING [I PANT BY T.G.C. BUILT -IN BASE III CONSTRUCTION FLOOR PLAN L� SCALE /40" -WJ VINYL WALLCOVERING ENTIRE ©PANT BY T.G.C. ) ©PANT BY T.C.C. ©VINYL WALLCOVERING ENTIRE WALL (U.N.0.) SUFI BY TENANT, INSTALLED BY T.G.C. NO FINISH 3 -10�' BUILT -IN BASE T.G.C. TO SuP'L & INST'L 4 I /4"H. BUILT -IN BASE W/ El APPLIED TO FACE & 0 ALL EXPOSED RETURNS (CARPET SUPPLIED & INSTALLED BY TENANT) - TYPICAL 40' -08" 1 NOTE: EXISTING CONCRETE SLAB THROUGHOUT TO BE PATCHED & D AS REO'D BY T.G.C. READY FOR OR NEW NEW FLOOR FINISHES. T.G.C. TO REMOVE & DISPOSE OF EXIST'G DOORS & PARTITIONS, BUILD - -OUTS & DISPLAY UNITS. T.G.C. TO CONSTRUCT VALANCE AS SHOWN USING 5/8' TYPE X" SHEETROCK ON Mil STUD FRAMING FROM 7' -0" A.F.F. TO 10' -6" NO BASE - SERVICE ISLAND CASH WRAP SHEET ROCK SOFFIT BY T.G.C. BOTTOM SALES AREA - CARPET FLOORING QH - CARPET BASE QH - LAY -IN CEILING 0 © VINYL WALLCOVERING :PAINT BY T.G.C. _ BUILT -IN BASE BUILT -IN BASE Mk NO FINISFill FLOORING TRANSITION LINE T.G.C. TO SUP'L & INST'L 4 I /4 "H. BUILT -IN BASE W/ QH CARPET APPLIED TO FACE & 0 ALL EXPOSED RETURNS (CARPET SUPPLIED & INSTALLED BY TENANT) - TYPICAL PAINT STOCKROOM WALLS BY TGC STOCKROOM LAY -IN CEILING SUP'L & INST'L BY T.C.C. 0 11' -0" A.F.F. 4' H. VINYL WALL BASE SUPPLIED & INSTALLED BY T.G.0 NO FINISH t a ._ 3 3 3 ' -10 }. NO BASE BUILT -IN b BAS( SERVICE ISUNO - NO BUILT -IN BASE _,bql5-0z40444 0 3 -IO, 4' 3U 31' -10R' Y 4 J• 9 TYPE ©WALL iii o AL �ii�ii i i1 T 11 11 11 iil ►III • TO L. TO FVRR OUT SALES AREA i ■ a DEMISING WALLS TIGHT W/ . LEASE LINE COLUMN PROJECTIONS. . r y L I .1I! JE SA O TSPC WALLS 5 P AINTED FIRE AISLE BY T.G.0 ) 4" VINYL BASE (TYP. ALL WALLS) - {O0,NNT ALL WALLS EXIST'G FIRE ALARM PANEL LOCATION OF EXIST'G & NEW ELECTRICAL PANEL & GEAR LAI >i 0 TELEPHONE EXISTING TOILET ROOM - V.C. TILE FLOOR - SHEETROCK CEILING STOCKROOM - V.C. TILE FLOORING - LAY -IN CEILING 0 - 4" VINYL WALL BASE (TYPICAL ALL WALLS - PAINT ALL WALLS D ELEVATION SCALE: I /4' =1' -O" G VINYL WALLCOVERING THIS AREA SUP'L BY TENANT, INST'L BY T.G.C. TO OF MOULDING 0 8 -6" A.F.F. ROLLING GRI LE SUP'L & INSTALLED BY TENANT. Cn AI ELEVATION SCALE: 1/4'1' -0" CW SALES AREA LAY -IN CEILING SUPPLIED & INSTALLED 0 10' -0' A.F.F. BY T.G.C. BUILT -IN BASE T.G.C. TO PAINT DOOR & FRAME TO MATCH © VINYL. S 6 S SALES AREA SHEETROCK CEILING SUFI & INST'L 0 SERVICE CORRIDOR S GENERAL CONSTRUCTION NOTES T.G.C. TO ENSURE THAT ALL FRAMING AND BLOCKING MATERIALS ARE NON- COMBUSTIBLE. ALL WOOD MUST BE KILN -DRIED TOP QUALITY MILL FINISH WOOD (STAMPED U.L. APPROVED) AND SO LABELLED. EACH BIDDER SHALL EXAMINE THE SITE AND FAMILIARIZE HIMSELF WRH ALL EXISTING CONDITIONS PRIOR TO BIDDING THE JOB. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF A MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR A LACK OF KNOWLEDGE ABOUT EXISTING CONDITIONS. POST SIGN ABOVE OR ADJACENT TO ENTRANCE, 1" HIGH LETTERS ON A CONTRASTING BACKGROUND; 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS.' FOR ILLUMINATED EXIT SIGNS SEE DRAWING El & E2. ALT. S SP HE ACK ETROC LED (T &K (GYP SUM BOARD) TO BE 5 /B" TYPE "X SHEETROCK FIRE TAPED AND THIS STORE EMPLOYS NO MORE THAN (4) EMPLOYEES PER SHIFT. EXIT DOOR TO HAVE CODE APPROVED EXIT DEVICE. SELF- CLOSER, POSITIVE LATCH AND FULL PERIMETER SMOKE SEAL CASKET ON FRAME. DOOR SHALL BE OPERABLE FROM EXITING SIDE WITOUT THE USE OF KEY, SPECIAL KNOWLEGDE OR SPECIAL EFFORT. O .G.0 LOR TO D'S CRITE SUFI & RIA. INST'L STOREFRONT BARRICADE IN ACCORDANCE MRH LAND T.G.0 TO ENSURE COLUMNS ARE SEALED TIGHT TO DECK ABOVE WITH 5 /B" TYPE %" SHEETROCK (T &S). (FRAME AS TIGHT AS POSSIBLE.) FOR STOREFRONT CONSTRUCTION SEE SHEET A2 & A3. GENERAL DEMOLITION NOTES T.G.C. TO REMOVE AND DISCARD ALL EXISTING FLOOR FINISHES. PATCH AND REPAIR AS REO'D. TO PREPARE SLAB TO RECEIVE NEW CARPET & /OR TILE FINISHES. T.C.C. TO REMOVE AND DISCARD EXISTING ELECTRIC EOUIPMENT NOT RELATED TO NEW DESIGN. SEE ET FOR NEW STORE LAYOUT. T.E.C. TO CAP ALI. ELECTRIC FLOOR OUTLETS NOT RELATIVE TO NEW DESIGN. T.G.C. TO TERMINATE ELECTRIC BELOW SLAB AND CAP ANY EXISTING SERVICES NOT RELATIVE TO NEW DESIGN. T.G.C. TO REMOVE AND DISCARD EXISTING STORE FIXTURES. T.G.C. TO REMOVE ALL EXISTING INTERIOR PARTITION CONSTRUCTION SHOWN DASHED ON PLAN. T.G.C. TO REMOVE AND DISCARD ALL EXISTING INTERIOR WALL FINISHES AND TREAT- MENTS. PATCH AND REPAIR SHEETROCK AS REO'O. AND PREPARE SURFACES TO RECEIVE NEW FINISHES T.G.C. TO REMOVE AND DISCARD ALL EXISTING CEILINGS WHICH INCLUDE, BUT IS NOT LIMITED TO, SOFFITS. ALL CEILING TILES & GRID, ETC... T.G.C. TO INSTALL NEW CEILING GRID AND TILES THROUGHOUT SPACE. T.G.C. TO REMOVE AND DISCARD ENTIRE EXISTING STOREFRONT. INCLUDING. BUT NOT LIMITED TO ENTRY DOORS, SILLS, SOFFITS, AND ALL OTHER RELATED CONSTRUCTION AND HARDWARE T.G.C. TO REMOVE AND DISCARD TOILET ROOM & TOILET FIXTURES. T.C.C. TO CAP PLUMBING LINES BELOW SUB. RECEIBED C ITY OFT4,Rcwi Lit I ,If'. .UDR PERMIT CENTER F�VlSiud �� L1 U c O �l n Et U O 0 Q J 90 0 a `,2 W o 0) O E Y Ya a U " U � 5- to C ° v `N nw WULti O aa 2 NNT/T!A DRAWING N0. 98133-Al ©VINYL WALLCOVERING ---{]C PAINT BY T.C.C. _ — - VINYL SUPPLIED WALLCOVERING THIS TENANT. T BY A / \ INSTA LLED B PP Y INSTAY T.G.C. _ _ _ =_NO FLAILS✓_ pe '0 3 S A l ELEVATION SCALE: 1/4' =1' -0' POP - OUT 5'12'Ii T NO FINISH I 3' -I0�' J 4' - 3�• BUILT -IN BASE NO BASE 00 PAINT TOILET RM. & STOCK- ROOM WALLS BY T.G.C. — STOCKROOM LAY -IN CEILING SUPPLIED & INSTALLED 0 AFT BY T.G.C. 4 H. VINTL WALL BASE SUPPLIED & L ST'L BY T.G.C ELEVATION SCALE: 1/4'=1' -0' 3 -IDS' IL -IN HAS 0 BASE P E A WAL - 31' NO BASE NO FINISH L SOREFRONFFIT AT INE 9' OF -10 " A.FF BT Y TG LINE OF MOULDING ABOVE 0 8' -6' A F F. BY i C C CENTER ROLLING LINE GRILLE MALL TILE FLOOR SUP'L. & INST'L BY T.G.C. FROM LEASE LINE TO BACKSIDE OF COLUMN. 'MOHAVE' OUARRY CAST 6' H. MOLDED BASE SUP'L & INST'L BY T.G.C. —{]G VINYL WALLCOVERING ENTIRE WALL (U.N. O.) SUP'L BY TENANT. INST L BY T.G.C. BUILT -IN BASE BUILT -IN BASE SALES AREA LAY -IN CEILING SUP'I. & INST'L. BY T.G.C. 0 10' -0' A F.F. SALES AREA LAY -IN CEILING SUP'L & INST'L BY T.C.C. ['VINYL WALLCOVERING [I PANT BY T.G.C. BUILT -IN BASE III CONSTRUCTION FLOOR PLAN L� SCALE /40" -WJ VINYL WALLCOVERING ENTIRE ©PANT BY T.G.C. ) ©PANT BY T.C.C. ©VINYL WALLCOVERING ENTIRE WALL (U.N.0.) SUFI BY TENANT, INSTALLED BY T.G.C. NO FINISH 3 -10�' BUILT -IN BASE T.G.C. TO SuP'L & INST'L 4 I /4"H. BUILT -IN BASE W/ El APPLIED TO FACE & 0 ALL EXPOSED RETURNS (CARPET SUPPLIED & INSTALLED BY TENANT) - TYPICAL 40' -08" 1 NOTE: EXISTING CONCRETE SLAB THROUGHOUT TO BE PATCHED & D AS REO'D BY T.G.C. READY FOR OR NEW NEW FLOOR FINISHES. T.G.C. TO REMOVE & DISPOSE OF EXIST'G DOORS & PARTITIONS, BUILD - -OUTS & DISPLAY UNITS. T.G.C. TO CONSTRUCT VALANCE AS SHOWN USING 5/8' TYPE X" SHEETROCK ON Mil STUD FRAMING FROM 7' -0" A.F.F. TO 10' -6" NO BASE - SERVICE ISLAND CASH WRAP SHEET ROCK SOFFIT BY T.G.C. BOTTOM SALES AREA - CARPET FLOORING QH - CARPET BASE QH - LAY -IN CEILING 0 © VINYL WALLCOVERING :PAINT BY T.G.C. _ BUILT -IN BASE BUILT -IN BASE Mk NO FINISFill FLOORING TRANSITION LINE T.G.C. TO SUP'L & INST'L 4 I /4 "H. BUILT -IN BASE W/ QH CARPET APPLIED TO FACE & 0 ALL EXPOSED RETURNS (CARPET SUPPLIED & INSTALLED BY TENANT) - TYPICAL PAINT STOCKROOM WALLS BY TGC STOCKROOM LAY -IN CEILING SUP'L & INST'L BY T.C.C. 0 11' -0" A.F.F. 4' H. VINYL WALL BASE SUPPLIED & INSTALLED BY T.G.0 NO FINISH t a ._ 3 3 3 ' -10 }. NO BASE BUILT -IN b BAS( SERVICE ISUNO - NO BUILT -IN BASE _,bql5-0z40444 0 3 -IO, 4' 3U 31' -10R' Y 4 J• 9 TYPE ©WALL iii o AL �ii�ii i i1 T 11 11 11 iil ►III • TO L. TO FVRR OUT SALES AREA i ■ a DEMISING WALLS TIGHT W/ . LEASE LINE COLUMN PROJECTIONS. . r y L I .1I! JE SA O TSPC WALLS 5 P AINTED FIRE AISLE BY T.G.0 ) 4" VINYL BASE (TYP. ALL WALLS) - {O0,NNT ALL WALLS EXIST'G FIRE ALARM PANEL LOCATION OF EXIST'G & NEW ELECTRICAL PANEL & GEAR LAI >i 0 TELEPHONE EXISTING TOILET ROOM - V.C. TILE FLOOR - SHEETROCK CEILING STOCKROOM - V.C. TILE FLOORING - LAY -IN CEILING 0 - 4" VINYL WALL BASE (TYPICAL ALL WALLS - PAINT ALL WALLS D ELEVATION SCALE: I /4' =1' -O" G VINYL WALLCOVERING THIS AREA SUP'L BY TENANT, INST'L BY T.G.C. TO OF MOULDING 0 8 -6" A.F.F. ROLLING GRI LE SUP'L & INSTALLED BY TENANT. Cn AI ELEVATION SCALE: 1/4'1' -0" CW SALES AREA LAY -IN CEILING SUPPLIED & INSTALLED 0 10' -0' A.F.F. BY T.G.C. BUILT -IN BASE T.G.C. TO PAINT DOOR & FRAME TO MATCH © VINYL. S 6 S SALES AREA SHEETROCK CEILING SUFI & INST'L 0 SERVICE CORRIDOR S GENERAL CONSTRUCTION NOTES T.G.C. TO ENSURE THAT ALL FRAMING AND BLOCKING MATERIALS ARE NON- COMBUSTIBLE. ALL WOOD MUST BE KILN -DRIED TOP QUALITY MILL FINISH WOOD (STAMPED U.L. APPROVED) AND SO LABELLED. EACH BIDDER SHALL EXAMINE THE SITE AND FAMILIARIZE HIMSELF WRH ALL EXISTING CONDITIONS PRIOR TO BIDDING THE JOB. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF A MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR A LACK OF KNOWLEDGE ABOUT EXISTING CONDITIONS. POST SIGN ABOVE OR ADJACENT TO ENTRANCE, 1" HIGH LETTERS ON A CONTRASTING BACKGROUND; 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS.' FOR ILLUMINATED EXIT SIGNS SEE DRAWING El & E2. ALT. S SP HE ACK ETROC LED (T &K (GYP SUM BOARD) TO BE 5 /B" TYPE "X SHEETROCK FIRE TAPED AND THIS STORE EMPLOYS NO MORE THAN (4) EMPLOYEES PER SHIFT. EXIT DOOR TO HAVE CODE APPROVED EXIT DEVICE. SELF- CLOSER, POSITIVE LATCH AND FULL PERIMETER SMOKE SEAL CASKET ON FRAME. DOOR SHALL BE OPERABLE FROM EXITING SIDE WITOUT THE USE OF KEY, SPECIAL KNOWLEGDE OR SPECIAL EFFORT. O .G.0 LOR TO D'S CRITE SUFI & RIA. INST'L STOREFRONT BARRICADE IN ACCORDANCE MRH LAND T.G.0 TO ENSURE COLUMNS ARE SEALED TIGHT TO DECK ABOVE WITH 5 /B" TYPE %" SHEETROCK (T &S). (FRAME AS TIGHT AS POSSIBLE.) FOR STOREFRONT CONSTRUCTION SEE SHEET A2 & A3. GENERAL DEMOLITION NOTES T.G.C. TO REMOVE AND DISCARD ALL EXISTING FLOOR FINISHES. PATCH AND REPAIR AS REO'D. TO PREPARE SLAB TO RECEIVE NEW CARPET & /OR TILE FINISHES. T.C.C. TO REMOVE AND DISCARD EXISTING ELECTRIC EOUIPMENT NOT RELATED TO NEW DESIGN. SEE ET FOR NEW STORE LAYOUT. T.E.C. TO CAP ALI. ELECTRIC FLOOR OUTLETS NOT RELATIVE TO NEW DESIGN. T.G.C. TO TERMINATE ELECTRIC BELOW SLAB AND CAP ANY EXISTING SERVICES NOT RELATIVE TO NEW DESIGN. T.G.C. TO REMOVE AND DISCARD EXISTING STORE FIXTURES. T.G.C. TO REMOVE ALL EXISTING INTERIOR PARTITION CONSTRUCTION SHOWN DASHED ON PLAN. T.G.C. TO REMOVE AND DISCARD ALL EXISTING INTERIOR WALL FINISHES AND TREAT- MENTS. PATCH AND REPAIR SHEETROCK AS REO'O. AND PREPARE SURFACES TO RECEIVE NEW FINISHES T.G.C. TO REMOVE AND DISCARD ALL EXISTING CEILINGS WHICH INCLUDE, BUT IS NOT LIMITED TO, SOFFITS. ALL CEILING TILES & GRID, ETC... T.G.C. TO INSTALL NEW CEILING GRID AND TILES THROUGHOUT SPACE. T.G.C. TO REMOVE AND DISCARD ENTIRE EXISTING STOREFRONT. INCLUDING. BUT NOT LIMITED TO ENTRY DOORS, SILLS, SOFFITS, AND ALL OTHER RELATED CONSTRUCTION AND HARDWARE T.G.C. TO REMOVE AND DISCARD TOILET ROOM & TOILET FIXTURES. T.C.C. TO CAP PLUMBING LINES BELOW SUB. RECEIBED C ITY OFT4,Rcwi Lit I ,If'. .UDR PERMIT CENTER F�VlSiud �� L1 U c O �l n Et U O 0 Q J 90 0 a `,2 W o 0) O E Y Ya a U " U � 5- to C ° v `N nw WULti O aa 2 NNT/T!A DRAWING N0. 98133-Al COLOR & FINISH SCHEDULE CODE MATERIAL DESCRIPTION & SPECIFICATIONS ❑A HIPLAM FORMICA #921 "BIRCH" ❑8 HIPLAM FORMICA #923 "SURF" C PAINT SHERWIN WILLIAMS #SW1093 - "BEIGE SAND" ❑D PAINT SHERWIN WILLIAMS #SW1053 - ° LIGHT MOVES" ❑E TILE VERONA MARBLE ?,'13D136 "BOTTICINO CLASSICO" EF TILE GROUT MAPEI #15 "BONE" © VINYL J.M. LYNNE #LT -5447 - "LYNLITE" EH CARPET BASE SHAW #38191 "RIVULET" �J PAINT SHERWIN WILLIAMS #SW1010 - "CRUSHED ICE" / WALL SCHEDULE , WALL SYMBOL WALL TYPE DESCRIPTION VARIES A EXISTNG MISING W TO EMAIN. .C. TO REPAIR AS DE REQUIRED , READY R FOR NEW T.G FINISHES. PATCH & T.G.C. TO ENSURE SHEETROCK IS SEALED TIGHT TO DECK ABOVE. L C B 5/8" TA. TY "X" SHEETROCK (T &S, BOTH SIDES) ON 3 5/8" 1R9N. PE METAL STUDS ® 16" s.c. SHEETROCK TO RUN FROM CONCRETE SLAB TO 12 -6" A.F.F. SUPPLIED & INSTALLED BY T.G.C. 4 1/4" TH. anminnoi nm m�nilnml � C 5/8" TH. TYPE "X SHEETROCK (T &S) ON ONE SIDE OF 3 -5/8" METAL STUD FRAMING. RUN SHEETROCK FROM CONCRETE SLAB TO 1D' -8" A.F.F. BY T.G.C. 4 7/8" TH. D O EXISTING 5/8" TH. TYPE "X" SHEETROCK (T &S). T.G.C. TO PATCH & REPAIR PARTITIONS READY FOR NEW FINISHES. C e )j VINYL WALLCOVERING > L C < -- - ©PAINT „� BY T.G.C. } ) C © / / kill WALLCOVERING THIS - I / AREA, SUP'L BY TENANT, INSTALLED BY T.G.C. ) ) NO NIS p \ I O FINISH S m � 6"" AEI IUD NO FINISH) f �...' - --�I) 4 -3" BUILT -IN BASE NO BASE ELEVATION SCALE 1/4 " =1' -0" g PAINT TOILET RM. & STOCK- ROOM WALLS BY T.G.C. l STOCKROOM LAY -IN CEILING V/`/ SUPPLIED 0" A. FF & INSTA " T.G.C I . i ' E 4" H. VINYL WALL BASE SUPPLIED & INSTL BY T.G.C. ELEVATION 3' -4 SCALE: 1/4 " =1 -0" 0 BASE BUILT-IN BASE TYPE WALL LEASE LINE LINE OF STOREFRONT SOFFIT AT 9' -10" AF �. BY T.G.C. LINE OF MOULDING ABOVE ® 8' -6" A.F.F. BY T.G.C. CENTERLINE OF O ROLLING GRILLE MALL TILE FLOOR SUP'L. & INST'L BY T.G.C. FROM LEASE LINE TO BACKSIDE OF COLUMN. "MOHAVE" QUARRY CAST 6" H. MOLDED BASE SUP'L & INST'L BY T.G.C. PE A WATYLL 713UILT - d BASE NO BASE -4r SALES AREA LAY -IN CEILING SUP'L & INST'L BY T.G.C. ® 10' -0" A.F.F. ©PAINT BY T.G.0 SALES AREA LAY -IN CEILING SUP'L & INST'L BY T.G.C. C 10' -0" A.F.F. W © VINYL WALLCOVERING �IPANT BY T.G.C. .fl VINYL WALLCOVERING ENTIRE WALL (U.N.O.) SUWL BY TENANT, INSTL BY T.G.C. NO FINISH - ,_ 14' -0" BUILT -IN BASE 3 ?' -10 " CONSTRUCTION L OR PL NN SCALE: i/4 " =1' -O" ©VINYL WALLCOVERING ENTIRE ©VINYL WALLCOVERING ENTIRE WALL (U.N.O.) SUP'L BY TENANT, INSTALLED BY T.G.C. T.G.C. TO FURR OUT SALES AR EA DEMISING WALLS TIGHT WI COLUMN PROJECTIONS. T.G.C. TO CONSTRUCT VALANCE AS SHOWN USING 5/8" TYPE "X" SHEETROCK ON MT'L STUD FRAMING FROM 7' -0" A.F.F. TO 10' -6 LENGTH OF VALANCE 44' -8" 10' -0" NO FINISH _. 31' -10g" BUILT -IN BASE T_G.C. TO SUP'L & INST'L 4 1/4 "H. BUILT -IN BASE W/ ❑H CARPET APPLIED TO FACE & W ALL EXPOSED RETURNS (CARPET SUPPLIED & INSTALLED BY TENANT) - TYPICAL NOTE: EXISTING CONCRETE SLAB THROUGHOUT TO BE PATCHED & REPAIRED AS REQ'D BY T.G.C. READY FOR NEW FLOOR FINISHES. T.G.C. TO REMOVE & DISPOSE OF EXIST'G DOORS & PARTITIONS, BUILD -OUTS & DISPLAY UNITS. - SERVICE ISLAND NO SER BUILT VICE -IN BAS ISLAND E - 58' -0 IC] PAINT BY T.G.C. CASH WRAP SHEET ROCK SOFFIT BY T.G.C. BOTTOM — ® 7-0" A.F.F. NO FINISH 0i" BUILT-IN BASE SALES AREA - CARPET FLOORING E - CARPET BASE E - LAY-IN CEILING 10' -0" A.F.F. © VINYL WALLCOVERING ©PAINT BY T.G.C. BUILT -IN BASE O E WALL 8 TYPE O WALL TYP T.G.C. TO SUP'L & INST'L 4 1/4 "H. BUILT -IN BASE W/ E CARPET APPLIED TO FACE A ®.ALL EXPOSED RETURNS (CARPET SUPPLIED & INSTALLED BY TENANT) - TYPICAL 1' -8 STOCKROOM LAY -IN CEILING SUP'L & INST'L BY T.G.C. ® 11' -0" A.F.F. ®PAINT STOCKROOM & TOILET WALLS BY T.G.C. 4" H. VINYL WALL BASE SUPPLIED & INSTALLED BY T.G.C. _ T >1 NO FINISH 4•-34" I 3' - 10 NO BASE III BUILT -IN BASE r� W „Mb- oz64q# ti 0 ■ii� Ill w ��N 1 11— J_ ' d� ' ippi I ii i- ! off i mmuignmumuy '1.11..1 I I \ 2 2' -0" POP - OUT 2' -3 3 X1 -3 7' -50 BUILT -IN BASE 0' -0 NO BASE 10' -0" 14' -0" FLOORING • i TRANSITION LINE _ C WALL 10' -5g O WALL TYPE TYPE A WALL EXIST'G FIRE ALARM PANEL LOCATION OF EXIST'G & NEW ELECTRICAL PANEL & GEAR PAINTED FIRE AISLE BY T.G.C. EXIST'G TELEPHONE EXISTING TOILET ROOM - V.C. TILE FLOOR - SHEETROCK CEILING AT 7' -6" A.F.F. - 4" VINYL BASE 7YP. ALL WALLS) - D AINT ALL WALLS STOCKROOM - V.C. TILE FLOORING - LAY -IN CEILING 11' -0 A.F.F. - 4 ", VINYL WALL BASE (TYPICAL ALL WALLS - PAINT ALL WALLS LE BUILT -IN BASE ELEVATION SCALE: 1/4"= I '-0" ['VINYL WALLCOVERING THIS AREA SUP'L .BY TENANT, INST'L BY T.G.C. TOP OF MOULDING ® 8 -6" A.F.F. ROLLING GRILLE SUP'L & INSTALLED BY TENANT. ELEVATION SCALE: I/4 " =1' -0" CW —SALES AREA LAY -IN CEILING SUPPLIED & INSTALLED 10' -0" A.F.F. BY T.G.C. BUILT -IN BASE T.G.C. TO PAINT DOOR & FRAME TO MATCH © VINYL. ENTRY AREA SHEETROCK CEILING ® 11' -0 7/8" —SALES AREA LAY -IN CEILING SUP'L & INST'L 10' -0" A.F.F. BY T.G.C. SERVICE CORRIDOR S O GENERAL CONSTRUCTION NOTES T.G.C. TO ENSURE THAT ALL FRAMING AND BLOCKING MATERIALS ARE NON- COMBUSTIBLE. ALL WOOD MUST BE KILN -DRIED TOP QUALITY MILL FINISH WOOD (STAMPED U.L. APPROVED) AND SO LABELLED. EACH BIDDER SHALL EXAMINE THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS PRIOR TO BIDDING THE JOB. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF A MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR A LACK OF KNOWLEDGE ABOUT EXISTING CONDITIONS. POST SIGN ABOVE OR ADJACENT TO ENTRANCE, 1" HIGH LETTERS ON A CONTRASTING BACKGROUND; 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." FOR ILLUMINATED EXIT SIGNS SEE DRAWING El & E2. ALL SHEETROCK (GYPSUM BOARD) TO BE 5/8" TYPE "X" SHEETROCK FIRE TAPED AND SPACKLED (T &S). THIS STORE EMPLOYS NO MORE THAN (4) EMPLOYEES PER SHIFT. EXIT DOOR TO HAVE CODE APPROVED EXIT DEVICE, SELF- CLOSER, POSITIVE LATCH AND FULL PERIMETER SMOKE SEAL GASKET ON FRAME. DOOR SHALL BE OPERABLE FROM EXITING SIDE WITOUT THE USE OF KEY, SPECIAL KNOWLEGDE OR SPECIAL EFFORT. T.G.0 TO SUP'L & INST'L STOREFRONT BARRICADE IN ACCORDANCE WITH LANDLORD'S CRITERIA. T.G.0 TO ENSURE COLUMNS ARE SEALED TIGHT TO DECK ABOVE WITH 5/8" TYPE "X" SHEETROCK (T &S). (FRAME AS TIGHT AS POSSIBLE.) FOR STOREFRONT CONSTRUCTION SEE SHEET AS A A3. GENERAL DEMOLITION NOTES T.G.C. TO REMOVE AND DISCARD ALL EXISTING FLOOR FINISHES. PATCH AND REPAIR AS REVD. TO PREPARE SLAB TO RECEIVE NEW CARPET & /OR TILE FINISHES. T.G.C. TO REMOVE AND DISCARD EXISTING ELECTRIC EQUIPMENT NOT RELATED TO NEW DESIGN. SEE El FOR NEW STORE LAYOUT. T.E.C. TO CAP ALL ELECTRIC FLOOR OUTLETS NOT RELATIVE TO NEW DESIGN. T.G.C. TO TERMINATE ELECTRIC BELOW SLAB AND CAP ANY EXISTING SERVICES NOT RELATIVE TO NEW DESIGN. T.G.C. TO REMOVE AND DISCARD EXISTING STORE FIXTURES. T.G.C. TO REMOVE ALL EXISTING INTERIOR PARTITION CONSTRUCTION SHOWN DASHED ON PLAN. T.G.C. TO REMOVE AND DISCARD ALL EXISTING INTERIOR WALL FINISHES AND TREAT- MENTS. PATCH AND REPAIR SHEETROCK AS REQ'D. AND PREPARE SURFACES TO RECEIVE NEW FINISHES T.G.C. TO REMOVE AND DISCARD ALL EXISTING CEILINGS WHICH INCLUDE, BUT IS NOT LIMITED TO, SOFFITS, ALL CEILING TILES & GRID, ETC... T.G.C. TO INSTALL NEW CEILING GRID AND TILES THROUGHOUT SPACE. T.G.C. TO REMOVE AND DISCARD ENTIRE EXISTING STOREFRONT, INCLUDING, BUT NOT LIMITED TO ENTRY DOORS, SILLS, SOFFITS, AND ALL OTHER RELATED CONSTRUCTION AND HARDWARE T.G.C. TO REMOVE AND DISCARD TOILET ROOM A TOILET FIXTURES. T.G.C. TO CAP PLUMBING LINES BELOW SLAB. V1.O?JD4A REVISION NO Z Q a0 O1 c co O Z w 5 0 0 X Z O 0 ce DC U (O 0 ( 0 i Ln N U C 0 V/ 0 N O O Z C 0 E • 4 3 NI DRAWING NO. 98133 -A1 STORE CONCEPT 1524 PARKSIDE • (972) DO NOT SCALE DRAWINGS OF SALES AR. LAY CLG DRAWN BY R.C.S. LANDLORD BULKHEAD CHECKED BY