HomeMy WebLinkAboutPermit D98-0285 - ECLIPSE ENGINEERING - WALLS AND FINISHESD98 -0285 375 Corporate Dr. Eclipse Engineering City of Tukwila r (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9075 Address: 375 CORPORATE DR S Suite No: Location: Category: AOFF Type: DEVPERM Zoning: TUC Pe -mit No: D98 -0285 Status: ISSUED Issued: 08/29/1998 Expires: 02/25/1999 Const Type: V -N Occupancy: OFFICE Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: SPRINKLERS Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: N Streams: Contractor License No: SGACO * *084BS OCCUPANT ECLIPSE ENGINEERING 375 CORPORATE DR S, TUKWILA WA 98188 OWNER LOWE NORTHWEST INVESTOR Phone: 206 575 -2120 600 UNIVERSITY ST #2820, SEATTLE WA 98101 CONTACT DAVID KEHLE Phone: 206 -433 -8997 12720 GATEWAY DR, SUITE 116, SEATTLE WA 98168 CONTRACTOR SGA CORPORATION Phone: 206 778 -2191 6414 204TH STREET S.W. #200, LYNNWOOD, WA 98036 **************************************************** * * * * * * * * * *. * * * * * * * * * * * * * * * * * * ** Permit Description: REMOVE EXISTING NON- BEARING WALLS, CONSTRUCT NEW TENANT WALLS AND FINISHES. i*************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 21,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: No: Size(in): .00 Flood Control Zone: Hauling: Start Time: End Time: Land Altering: .Cut: Fill: Landscape Irrigation: Moving Oversized Load: Start Time: End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: Public: ***********************.***•************************** * * *'* * * * * * * * * * * * * * * * * * ** * * * * *** TOTAL DEVELOPMENT PERMIT FEES: $ 557.66 ************************************** } k*********** * * * ** * * * * * * * * * * * * * * * * * * * * * * * * ** 171-(,e4.- Permit Center Authorized Signature: 1A6L_ Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the perf•rmance of work. I am authorized to sign for and obtain this developmen •lrmit. /� Signatur / ' ArAijk /� O Date: S 3I -g8 Print Name: I+'l.Q 45 7Jaj/frw This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKNILA Address: 375 CORPORATE DR S Suite: Tenant: Type: DEYP[RM Purcel #: 262304-9075 Permit No 098-;285 Status: ZSSVED Applied: 08/2171S92 IssueUt 08/29/1998 1,*^At'tAa**a+A&+++^+/+****a**AAA*f**^*A**.4-AA**+/++****�+x+*«+�k^++*Ik* Permit Conditions: 1. No uhanges wi)/ be made to the plans unless approved by the Architect or Engineer and the Tukuija Uuildinq Division. 2. L|ertr1cal yhsll:be'obtained .thr.ough the Washington State Division of yLaburand Industries and �al6l elpctrical work will be �ospec ted by`that agency (24}8-630 S. Plumbing permit, obtained`througi the- le-Ki np County Dep,a'tmenk „of. POblic Hgalth. Plumbinq�wil1��be inspecte:that aQency', includjnp all pas pjpinq'���` (296'47 .' � • - ' 4^ All mecha/1io,a1 work •hall be.`und+p seuarate pei.mft \issued` by the City'of •. All pmite, inspection',`ref.:!urds, �nd spprovec|Ip)w � h avai iible/.at the.iub site. Prior to the start f`any ' struCtion.'`These' doCuNents ere. to he 0aintained'and inspedton approval, is granted. 6. An h \w'n8 Yin grid and -light fixture. iOstal7ati"n req re d to mee t l ateral b raci ng requ iremen t s f �r. � e i� Sm d Zone:3. ` 7. Partition walls.attac ed tV ceili08 grid m6st he lateraTl- br@ded if over eight (�) f��t in len��M. C. /\T1 'c0nstructiVn,.t0 be done, fn conformance-with approve plans and. requirements of the UMiform`BOldin0 COdeM.,997 Edition) as amended; Uniform MethuniCal' Cod� (l�97 E�ft '�' and`Mashjn8tonState Energy Code ( g7 Edition} 9- ValiditvOf`P8rmit. The o plans,,�speoifivatiuns, l ' � 5trued' to he a permit f t � of 6n .` f �h provisions f the :building �' ��w � Pr0v � 0n5 � � g V f any other Ordinance .of the iurisdittion. 41(5`0' i t ,preSumini0o give authOrity.t.0, vimlate or cancel the provisionSof node ShaT i . - !b� valid. 10' VEN}lLA|ID on �D FOR ALL ROOMS AND �PA� NEW OR EXISTING'IWILDINGS IN CONFORMANCE WITH THE UNIFORM' BUILDING COD� E 4/��H i S7 VENTIL D INDOOR AIR QUALITY,HCODE, �`*� �n �m���w� *�c' *n CITY OF TUKWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ School /College /University ❑ Other ■ arehouse ❑Hospital P4 office Value of Construct If yes, extent of change: (Attach additional sheet if necessary) Site Address: L O' ''1 -1 ���;' +' �1 City Stet /1p. Tax FrcJ Num er: Property Ownerl�4, rr ae Phone: /ra a 4 iC ) n' Str-- •dr-..s: City to e/ '• Fax #: Contractor: Phone: Street Address: City State /Zip: Fax #: ArcMc :ip lot, � 401.,,,i, Phone: x d, j' 611 ,(,�,(� ,G� 3 Str -et ■ ∎ dres CI ate '• Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: aril Phone:A�y MI/ Stra i i_ e��1 Wtaft Fax #: Mel . Description of work to be done: ir -''wil I4 :s ''H' 0-4 Ill' .Ifs / ��' tAirtutfi WHO -1E401 4 1 bWO r11419-1t Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ School /College /University ❑ Other ■ arehouse ❑Hospital P4 office Will there be a change of use? in yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes no Existing fire protection features: A sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: IlL o &'Z existing Area of Construction: (sq. ft.) i^.'-p [w Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING::: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent it Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: • Date application expires: 2 .-2-(-qci CTPERMIT.DOC 1/29/97 SASE SIGN BACK:ORAPPLICATION FO. Applicatl n ken by: (initials) AL4 COMMERCIALIMU1.74F, YT�'NANT I�1pROVEMEIIYT /AL 7,�A T►ON PERMIT ApPLlC,4TIOM5, `' • . IGI BE SUBMITTED WIiH THE FOTLi7WING, . • . ALL DRAWINGtS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL,ENGINEER OR CIVIL ENGINEER i-- ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN r' BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Complete Legal Description Er ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Fo . : usiness Declaration required (Form H -10). Four 4) se f working drawings (five(5) sets for structural work), which include : ❑ lSite Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements i'ipe 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions • NO &E 4. Location of driveways, parking, loading & service areas t4J4 5. Recycle collection location and area calculations (change of use only) 14/At 6. Location and screening of outdoor storage (change of use only) drla 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries fA 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 1, 0` 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved til 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) tAik 11. Location and gross floor area of existing structure with dimensions and setback ( 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ 1Floor plan: show location of tenant space with proposed use of each room labeled ❑ Pr Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of �-1 any hazardous materials; dimensions of proposed tenant space. U Vicinity Map showing location of site T ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. I-1 cr Indicate proposed construction of tenant space or addition and walls being demolished ❑ , Er Construction details a ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Er Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. Ft ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). a ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. a ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ' 1, W•RIZED AGENT: Signature: �AIR_Sr Date: MEM i ... ■:may %6•_1 ► a01 ;� Print nam 9 to , Phone4..3.'� Address 17_ T k i- , VO . r,'110 City /State /Zip CTPERMIT.DOC 1/29/97 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECQr O Retain a copy with p. . nit v 9c5 -0 Zo PERMIT NO. (206) 431 -3670 Protect: s Type • ' nspection: Da . / 7 A- 75s: (o Poe-Ar Special instructs ns: 1 Date wan d: C7 f y� a.m. p.m. Requester: Phone No.: proved per applicable codes. Corrections required prior to approval. Date; 9,6 /It r $42.00'REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECQ''D Retain a copy with p‘._,init INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Mk- 10.2k-s-- PERMIT NO. (206) 431-3670 Proj Pri oi se Eii3i n , Type of inspec • n: F, Pt Address: 3 75 0 orporak br S. Date called: io IF(lq Special instructior1s: . Date wante f d: 1019 qi a.m. P.m. Requrrij Ph5leorn:CW g- S!' Approved per applicable codes. orrections required prior to approval. COMMENTS: 17_,Co)g-r.6 ,r-/u/di4ze_ Inspe Date: 1i7 r $42.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: {25 INSPECTION NO. INSPECTION RECO9 Retain a copy with pd,_1it CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 028 PERMIT NO. (206) 431-3670 / - 5--••4‘ Project: r Gt Type of inspectiorq_ i 1 Address: 3 7 _. e-ei br i Date called: Special instructions: 1 7 0 t Date wanted: - Xrirl: /0 21 Requester: N° • Phone 2— Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector Date: $42.00 REINSPECTIONVPEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: •1'rj �:i.'t4CJ"`�'- K�n�:.�.. _ , y...." m. ��� ;,�4�:��.^,.��c',,�..:;ftT^;zN .r.. w::s -.,q^; •y1•, -. .. : INSPECI'ION RECD Retain a copy with pit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Project: e e1/6// Alf Type nsp tion t,....r (c) L--e i I ( Address: r Date called: �G Special instructions: Date wanted: 7-36-2r as, Requester: Gob Caa. P one flo.: w,/ G„ 5,,..5._3G Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7,0 Ci(-4 1,37 I- itD , • 1,12'e ocI h 1,-;-7,0 4-7 / Inspector* Date: $42(DD- REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 v a ., -. ;3:. -y ._...-- .— ....--- �.- �.•:�r v�csc1: zs-...:¢ mr'...,... �, �rr�je.., �. Sa ?a,^,.- �C'�-n4:i!k.rc...,�r+�., c� INSPECTION REC Retain a copy with P. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 DqP-62Es-- PERMIT NO. (206) 431 -3670 Project: Type of inspectign�r A j� Addreseo / Q Date called: C ` / r, %/Zf/ - Special instructio . . Date wanted: a.m. Requester: Bo 1 Phone No 6 'L ---S' 5 ar Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: id- ( Date: G` 2 -- 1 1 $42.00 t INSPECTION F€ REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.. Receipt No.: Date: t•' {rcs.+a:; ; ^-,(` ., •=':7.,•'.'�?„"" s. 3:.,," �ai7.:'; �r ::r.•;yP,)T...'':'�;^'•u.::?`n .k��;;;i %7n. wi,�:v I INSPECT II ti NO. INSPECTION REC Retain a copy with .tit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 PERMIT NO. (206) 431 -3670 Project: - Type of inspection: �{ y� Address: � Date called: n rke Special instructions: �`" ]r (.�- Lt_. �j/ Date wanted: /y j� a co Y �U %" �P.m1 Requester: ac b Phone N`91_3r+ Approved per applicable codes. Corrections required prior to approval. COMIC111ENTS: Inspector: Date: [ 1 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .,. . :^';•r!r."TT' %� >i,'.1„`r7.i•4 s;'�, �nr .r�j� ?'mCY'4'fi',.r4w�i4:; " ;:t t nr�§%Y�'Sx'w:.a-- .'1iM"' rvrrnrr+•, -.o ■ INSPECTION RECQ Retain a copy with pb.. it INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Project: /i 944\ Type of inspection: Address: 37 0-0 ' r- r-. Date called: //?/? iU Special instructions• -�//�/�� Date wanted: a.m. p.m. Requester: (3c...th) Phone �oc - s 3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: C_GtL. e!4_,/ cr // Inspector: ! A Date9v� - V 1 $42. 0 REINSPECTION EE REQUIRED. Prior to inspection,( fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: City of Tukwila Fire Department John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name &64-- P &; ,Af('I 'A/ale/A( er? Address 375 C az. s• Thomas P. Keefe, Fire Chief Permit No. Dw Retain current inspection schedule Needs shift inspection Suite # VApproved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM Rev. 2/19/98 Dat /Oa T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • .Phone: (206) 57574404 • Fax (206).575-4439 +*A*it+� *a�A*++*+4***A*.**ic*+*ait*^**k*�a*a+*-AW**A.A6*+4+++**+* :ICY OF TUKNILA, NA � � ' � TRANSMIT` +A*****A+A*++***A*Aa*A***Wa^+`a**A****a***.A*a******a*A+*k+ TRANSMIT Number: R9700821 Amount: 339.75 08/29/98 16:00 Payment Method: CHECK Notation: DAVID KEHLE ARCH Init: BLH ` Permit No: D98-0285 Type: DEVpERM DEVELOPMENT PERMIT Parcel Not 262304-9075 Site Address: 375 CORPORAlE DR S Total Fees: ` � 557,66 This Payment 339.75 , Total ALL Pmts: '' .557-66 Balance: . � �� ,00� + * � \*****�****�***kA**�****kA**�v(�+*�+* "***^+^�*+�*���,�+ +�a*++ a � Account Cod'? 000/322.100 000/386.904 Descpiption BUILDING - NONRES STATE BUILDING SURG1fARGE Amount '355.35' • 5262709/09 718,80 ,. T'.'377".:"Tr(.'-t,"r:t4F-77,.:F.'rr:77.Tfr7'77rr.'qrfr.7:',.7rf:77F,'Ffr"r7r777,777:7,727 : ' . A . _ 1.. **A **A 4 * *A * * A* * *** * A * *** * ** * * * * A * 4. A * * * **** ***A *A A** A *A * *4 L'JTY Or TUKWILA'. WA : - * ¼ * * A * * A *k*. * A * * A * A * * A * A * ¼k ¼ * * * A. A * * ¼ * A * * ¼k TRANSMIT Number: U9700815 'Amount: - 217.94 08/21198 Payment Methodt CHECK Notation:. DAVID ICEHLE1 ARCH Init tJ ' • Permit Ncz-,D58 Type:'DEVPERM DEVELOPMENT PERMI. Paroel 262304-9075 Site AddreSa.: 87'6 CORPORATE DR 8 Total Fee 537 t. This Payment 217.91 Total'ALL:Pmts: 717. t) 1: s: ..- Balance: - , A****A*A***-AAA*A4c***A**A*A*****A*AAAAAA:*****A******Iikit4******* Account 'Code' Description 000/245.830 PLAN CHECK— NONRES 217 'J CITY OF TUKWILA RECEIPT PW DCD 217.91 CHECK 217.91 08/24/98 19: 16:53 0097 5005 SEP 21 '98 1217 D KEHL . ARCHITECT f JI` } .._ _ _• _ — • -•• P. 1/1 - - PIT LI! S. david architect September 21, 1998 City of Tukwila 6200 Southcenter Blvd. Tukwila, Washington 98188 Attn: Mr. Dave Larson Inspector Re: Eclipse Engineering Permit #D980285 Dear Dave, post -1t• Fax Note At the request of the field superintendent,1Bob Waage of SGA.Corporation, it is acceptable to change the stud gauge on.the• % heightwalls.from 204a. to 25 ga. Sincerely, cc-1*mA- /14-- David Kettle DK/mt cc: Bob Waage at9733uat9-21 12720 GATEWAY. DRIVE, SUITE 116 (206) 433 -8997 SEATTLE, WA 98168 FAX (206) 246 -8369 IP ACTIVITY NUMBER: D98 -0285 DATE: 8 -21 -98 PROJECT NAME: ECLIPSE ENGINEERING XX Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision After Permit Is Issued DEPARTMENTS: BJ din Division Public orks Fire 1 revention Pla g Division Ave_ Structural U Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 8-25 -98 Complete Incomplete Not Applicable n Comments: TUES /THURS ROUTING: Please Route n No further Review Required Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) n REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 9 -22 -98 Approved Approved with Conditions Not Approved (attach comments) n REVIEWERS INITIALS: DATE: IINIONIMI•111•1! CORRECTION DETERMINATION: DUE DATE: Approved • Approved with Conditions Not Approved (attach comments) n REVIEWERS INITIALS: DATE: \PR-ROUTE.DOC 6/95 City of Tukwila Fire Department Fire Department Review Control #D98 -0285 (512) John W. Rants, Mayor Thomas P. Keefe, Fire Chief August 26, 1998 Re: Eclipse Engineering - 375 Corporate Drive South, Suite #100 Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1- 1212.8) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone.. (206) 575-44D4 • Fax (206) .575-4439 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fin? Chief require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of • such condition or violation. Headquarters Station: 444Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575 -4439 City �f Tukwila Fire Department Page number 3 Yours truly; John W. Rants, Mayor The Tukwila Fire Prevention Bureau cc: TFD file ncd. Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 57$-4404 • Fax (206) 575-4439 1,62.5.052.00u (v971 REGISTERED AS PROVIDED.-SY.LAW AS A• DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGISTRATION NUMBER ±CCD1 -,SGACO *:*:084BS •.01/10/19;99. O�k"FECT3trE DATE:: 01,/10/4:992... S G A CORPORATION • 6414 204TH ST SW 200 'LYNNWOOD WA 98036 -5973 Eli And Lisp ;a). CtIli(cat I REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGISTRATION NUMBER CC01 SGACO* *084BS 01/10/1999 EFFECTIVE DATE 01/10/1992 S G A CORPORATION 6414 204TH ST SW 200 LYNNWO WA 98036-5973.y Signal e • ros.02.00 6:'971 // P1 DEPARTMENT OF LABOR AND INDUSTJ Please Remove And Sian Identification Card Before Placing In Billfold FILE COPY SECOND FLOOR KEY PLAN TYPICAL INTERIOR FINISH KORTRON OR PLASTIC LAMINATE WIRE PULLS 25 D' LUNCH ROOM COUNTER IPASATE PERMIT NTF1'JIRED FOR: MECHANICAL LECTRICAL ❑ PLUMBING CAS PIP/P/C D iHe ()MGM D'1& Oi67" SUSPENDED CEILING REFRIG. I SINK GR SFI L- .:s - CI=O > . --L DRAWERS WMETAL. x GUIDES RUDDER EASE 4 PLASTIC LAMINATE BACKSPLASH AND COUNTER TOP PLASTIC LAMINATED FACED FLUSH OVERLAY CABINETS W /ADJUSTABLE SHELVES C EXISTING / DEMO PLAN 5' 10' IT 25' 35' SCALE I/O" • I' -0" LEGAL DESCRIPTION THAT PORTION OF THE EAST HALF OF THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST U.N. IN KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS' BEGINNING AT THE NORTHEAST CORNER OF SAID EAST HALF WHICH IS NORTH 88005'42' WEST ALONG THE NORTH LINE OF SAID SOUTHEAST QUARTER A DISTANCE OF 1,339.34 FEET FROM THE NORTHEAST CORNER OF SAID SOUTHEAST QUARTER; THENCE SOUTH 01047'29' WEST ALONG THE EAST LINE. OF SAID EAST HALF A DISTANCE OF 1,322.34 FEET TO THE SOUTHEAST CORNER THEREOF; DISTANCE OF 659.35 FEET TO THE WEST LINE OF THE LAST 659.34 FEET OF SAID EAST HALF; THENCE NORTH 01047'29' EAST ALONG SAID WEST LINE A DISTANCE OF 1,320, 30 FEET TO TIE NORTH LINE OF SAID EAST HALF; THENCE SOUTH 88005'42' EAST ALONG SAID NORTH LINE A DISTANCE OF 659.34 FEET TO THE POINT OF BEGINNING; EXCEPT THE EAST 30 FEET THEREOF FOR ROAD[ ALSO EXCEPT RAILROAD TRACKAGE AS RESERVED BY UNION PACIFIC RAILROAD COMPANY AS DISCLOSED BY DEED RECORDED UNDER RECORDING NO. 7607070502; ALSO EXCEPT THAT PORTION OF SAID SUBDIVISION DESCRIBED AS FOLLOWS BEGINNING AT A POINT ON THE WESTERLY MARGIN O ANDOVER PARK VEST, WHICH POINT BEARS NORTH 88005'42' WEST 1,369.34 FEET ALONG THE NORTHERLY LINE OF SAID SOUTHEAST QUARTER, AND. SOUTH 01047'29' WEST 451.30 FEET ALONG SAID WESTERLY MARGIN OF ANDOVER PARK WEST FROM THE NORTHEAST CORNER OF SAID SOUTHEAST QUARTER; THENCE FROM SAID POINT OF BEGINNING LEAVING SAID WESTERLY MARGIN, TANGENT TO THE PRECEDING COURSE, ALONG THE ARC O A CURVE TO THE RIGHT HATING A RADIUS OF 50,000 FEET AND A CENTRAL ANGLE OF 90006'49' AN ARC LENGTH OF 78.64 FEET TO A POINT ON A LINE THAT IS PARALLEL TD AND 501.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST QUARTER; THENCE ALONG SAID PARALLEL LINE NORTH 88o05'42' WEST 326.76 FEET; THENCE LEAVING LAST SAID PARALLEL LINE TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 15,00 FEET AND A CENTRAL ANGLE OF 54045'56', AN ARC DISTANCE OF 14.34 FEET TO A POINT O REVERSE CURVATURE, THENCE TANGENT TO THE PRECEDING CRAVE ALONG THE ABC OF A CURVE TO THE LEFT,'. HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 2R9o3I'52' AN ARC DISTANCE OF 252.66 FEET TO A POINT O REVERSE CURVATURE) THENCE TANGENT TO THE PRECEDING CURVE ALONG' THE ARC OF A CURVE TO THE RIGHT, HAVING A RADIUS OF 15.00 FEET, AND A CENTRAL ANGLE OF 54045'56', AN ARC LENGTH O 14,34 FEET TO A LINE THAT IS PARALLEL TO AND 546.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST QUARTER; THENCE ALONG SAID PARALLEL LINE SOUTH 88005'42' EAST 327.05 FEET; THENCE LEAVING SAID PARALLEL LINE, TANGENT TO THE PRECEDING COURSE, ALONG. THE ARC OF A CURSE TO THE RIGHT, HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 89053'11', AN ARC LENGTH OF 78.44 FEET TO A POINT ON THE WESTERLY MARGIN OF ANDOVER PARK WEST; THENCE ALONG SAID WESTERLY MARGIN NORTH 01047'29' EAST 145.00 FEET TO HIE POINT OF BEGINNING; • ALSO EXCEPT THAT PORTION MORE PARTICULARLY DESCRIBED AS FOLLOWS' BEGINNING AT A POINT ON THE WESTERLY MARGIN OF ANDOVER PARK VEST WHICH POINT BEARS NORTH 88005'42' VEST 1,369.34 FEET ALONG THE QUARTER AND SOUTH 01047'29' WEST NORTHERLY T Y LINE OF SAID SOUTHEAST 97733 .330 0 FEET ALONG SAID WESTERLY MARGIN OF ANDOVER PARK VEST FROM THE NORTHEAST CORNER IF SAID SOUTHEAST QUARTER; THENCE. FROM SAID POINT OF BEGINNING LEAVING SAID WESTERLY MARGIN, TANGENT TO THE PRECEDING COURSE, ALONG THE ARCH OF A CURVE TO THE RIGHT HAVING A RADI6 ' OF 50.00 FEET AND A CENTRAL ANGLE OF 90006'49', AN ARC LENGTH OF 78.64 FEET. TO A POINT ON A LINE THAT IS PARALLEL TO AND 1,023.40 FEET SOUTHERLY OF THE NORTHERLY LINE SF SAID SOUTHWEST QUARTER; THENCE ALONG SAID PARALLEL LINE NORTH 88005'42' VEST 326.76 FEET; THENCE. LEAVING LAST. SAID PARALLEL LINE TANGENT TO THE PRECEDING COURSE ALONG THE ARC EF A CARVE TO TIE RIGHT HAVING A RADIUS OF 15,00 FEET AND A CENTRN. ANGLE OF 54045'56', AN ARC DISTANCE OF 14.34 FEET TO A POINT DE REVERSE CURVATURE; THENCE TANGENT TO THE PRECEDING CURVE ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 289031'52', AN ARC DISTANCE OF 252.66 FEET TO A POINT OF REVERSE CURVATUREI THENCE TANGENT TO THE PRECEDING CURVE ALONG THE ARC O A CURVE TO THE RIGHT HAVING A RADIUS OF 15.00 FEET AND A CENTRAL ANGLE OF 54045'56', AN ARC LENGTH OF 14.34 FEET TO A LINE THAT IS PARALLEL TO AND 1,068.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST CARTER; THENCE ALONG SAID PARALLEL LINE SOUTH 88005'42' EAST 327.5 FEET, THENCE LEAVING SAID PARALLEL LINE, TANGENT TD TIE PRECEDING COURSE, ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS CI 50,00 FEET AND A CENTRAL ANGLE OF 89053'11', AN. ARC LENGTH OF 78.44 FEET TO POINT ON THE WESTERLY MARGIN OF ANDOVER PARK WEST; THENCE ALONG SAID WESTERLY MARGIN NORTH 01047'29' EAST 145.00 FEET TO THE POINT OF BEGINNING. GENERAL I tWC-1 LAND USE' C.M. INWST CODE' .C. V/ AMENDMENTS SEISMIC ZONE' 3 FIRE ZONE' III OCCUPANCY' B OFFICE CONSTRUCTION TYPE VN SPRINKLERED PARKING' STANDARD 110 STALLS COMPACT = 2 HANDICAPPED = 2 TOTAL PARKING 114 PARKING RATIO' 1 /150 SF BUILDING' ADDRESS 685 ANDOVER PARK W TAX PARCEL NUMBER' 262304- 9075 -00 .(FOR ENTIRE PARCEL) TENANT. AREA = 2,059.6 S.F. LIGHTING NOTES: LIGHTING IS EXEMPT FROM ENERGY CODE SINCE LESS THAN 602 OF THE FIXTURES ARE NEW AND INSTALLED WATTAGE IS NOT BERG INCREASED. FLOOR PLAN 0' 5' 10' 15' 25' 35' SCALE I/8" • I' -0" ROOM SCHEDULE: (REMOVE EXISTING CARPET V BASE) 1 - 10 FLOOR: WALLS' CEILING' 10 FLOOR WALLS CEILING' DOOR SCHEDULE •I.NO32 CONSTRUCTION TO GTE. BD. CEILING APOVE (WP I0T1) 3 Rs' x 10 GA. a 14' DL. 05/e' TOPS X EACH SIDE I" TTEES_SCRELS s 3' VERTICAL JOINTS 5' OW • FLUOR CEILING TILES AT NTERIEDIATE TRACKS CARPET W /RUBBER BASE GYP. BD. PAINTED SUSPENDED ACOUSTIC - PATCH AND REPAIR REPLACE TILES AND GRIDS AS REQUIRED VET V /RUBBER BASE GYP. BD. PAINTED SUSPENDED ACOUSTIC - PATCH B REPAIR REPLACE TILES AND GRIDS AS REQUIRED Fly DOOR SCHEDULE (NEW DOORS TO HAVE LEVER HANDLES, MATCH EXISTING FINISH AND STYLE, REUSE EXISTING DOORS AND FRAMES) I, 2 NEW OR RE -USED 3'-0' x 7' -0' S.C. WOOD WITH METAL JAMBS, LATCHSETS, SILENCERS, WALLS STOP 3, 4 NEW OR RE -USED 3' - 0' X 7' -0' S C. WOOD WITH METAL JAMB. 5, 6 LOCKSET, SILENCER, WALL STOP, THRESHOLD. OPENINGS, 3' -0' X 7' -0' GYP. BD_ RETIIRNED. EXISTING 3' -0' X 7' -0' S.C. WOOD- 20 MIN RATED HOLLOW METAL FRAME RE -KEY LOCK. WALL SCHEDULE NOTES: 3 I/2' x 25 GA 8 24' 0 W/5/8' GYP. BD EACH SIDE, 3 1/2' x 20 GA 8 24' C.C. V/5/8' GYP BD. EACH SITE "42' A.G.F. 6' x 20 GA P 24' 0 . W/5/8' GYP. BD. EACH SIDE. FULL HEIGHT, SOUND INSULATED DEMISING WALL I) EXISTING BUILDING ENVELOPE IS NOT BEING MODIFIED. HAW.. ZONING AND THRMOSTAT''LOCATIONS 10 BE REVIEWED AND APPROVED BY TENANT AND OWNER. 2) LIGHTING IS BEING RE -USED (AT LEAST 652) AND IS THEREFORE EXEMPT FROM ENERGY CODE REQUIREMENTS. 3) LIGHT CIRCUITING SHALL NOT EXCEED 902 OF A 20 AMP CIRCUIT. MULTI LEVEL SWITCHING, WITH IN 12' OF WINDOW VAL.. -- n- Irill irla MIIMIIIIIIIN I -� re irlal ▪ l ► im itir Miltil 11 Pi ER I sue _. Mi N16 Il i a7 1.9=111.111 INIONNINIBISIIII IMIMIIIIIMIIIIIBIIMIIIIIIIIII IIIIIIIWIMELIIIBMIMIMIIIIIII 111101111111MIN NM /I I� CEILING TILES l' x 4' SECCND LOCK TEGIJLAR EDGE • D.P AFT 6 REFLECTED CEILING PLAN 0' 5' 10' 15' SCALE I/O" • I' -0" SCOPE OF WORK REMOVE EXISTING NON - BEARING WALLS, CARPET AND BASE, INSTALL NON- BEARING TENANT WALLS, DOORS, FINISHES, ETC LEGEND l F C F >$i FOUR -PLE/ # DUPLEX OUTLET 15' 35 WALL TELEPHONE AND DATA OUTLET. MJDRIMG. FONTAI'I AND PULL STRING UNLY. C, ID THERMOSTAT Errd ILLUMINATED EXIT SIGN _ 2' X 4' EXISTING LIGHT TO BF REMOVED DR RELOCATES. 1 _:y 2' X 4' EXISTING LIGHT TO REMAIN INDLVIINIA_ OFFICE 2' X 4' NEW LIGHT OR RELOCATED RECESSED LIGHTS TO BE REMOVED 150 VAN'S EACH 0010SE ExISTL0 -H(XIR G/P BD CEILING W'O : LGHTS r I T EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE O' CEILING NEW STEEL STUD WALL WITH SOUND INSULATION FORM ?"AC/ CAULK AT BASE, 2' -0' E S AT OILING WITH SOUND BATTS EXISTING WALL TO BE REMOVED. NEW DOOR EXISTING DOOR EXISTING DOOR TO BE REMOVED RECEIVED CITY OF TUKWILA )alit 'I 1 k99F; PERMIT CENTER • 1 O • 0 N w 'R < 0 0 co ® Lil� ® LD < z Ix w Z a >o cm. • o z 0 • w 2 za I ' z < IU NcoH i TA -1 08/19/98 O8 05 ,, , (:ADF, FCLIP5E x A -01 MATCH EXISTING FINISHES �INTE RI ❑R DOOR JAMB SCALE 1 1/2' = I' -0' NOTE, I. USE IN SEISMIC AREA AS REO'D BY CODE 2. SUPPORTING WIRES TO BE •N GA. • 4' -0" 0/C CONNECTED TO BOTTOM CHORD OF TRUSS WI 1 I/4" EYE SCREWS. EMBED I" MIN. 3. UP TO S' -0" EXISTING JOISTS -- 1 So 0/ SEISMIC BRACING NO SCALE CN -RATED CLG NEW NON- CcI8115TIBLE 3 5 /S• STL. STUDS SAFE AS EXISTS HALL . 5/8" TYPE 'X' GYP BD 150, /D INSIL IF SHCIN CN PLAN/ OOR SECTION INSTALL •2 GA. VERTICAL WIRE CONNECTED TO MAIN RUNNER I TO STRUCTURE ABOVE. INSTALL A SECTION OF I/O" RIGID STEEL CONDUIT W/VERTICAL WIRE RUNNING THRI CENTER OF PIPE. PIPE TO RUN FROM TOP OF TEE TO BOTTOM OF STRUCTURE ABOVE, WRAP END OF VERTICAL WIRE AROUND PIPE BOTTOM. — CROSS RUNNER INSTALL •2 GA. WIRE CROSS BRACING IN EA. PLANE OF MAIN RUNNER 12' -0" 0/C c 45 ANGLE IN BOTH DIRECTIONS WI THE FIRST POINT WITHIN 6' -0 " FROM EA, WALL 2 111' RIBBER BASE • CA " CORRID ❑R SECTION (1 -HOUR) WALL SECTI ❑N / SCALE 3/8' = 1' -0' SECTION I I/2 = 1' -0 EXISTING ROOF DECK- 59WD CAULK PRIOR TO ATTACHAY GYP. BD. \ DEMISING OFFICE WALL SCALE 1 1/2' = I' -0' PANT BLACK—, 5/4° x 1" FILLER BLACK GASKETS V4• EACH SIDE CF FILLER 22' ODE SOND BATTS EA SCE WALL • SOUND WALL MAIN RUNNER � }WALL TO MULLION �/ SCALE. 1 1/2' = P -0' FOR ' HALLS GREATER THAN 8'- D" N w /DT.. OT4CIP .N NTENAECTNi W.ti:.. PROVIDE Ilya, WIRES SPLAYED • 41 TO EYE Y REW • ROOF AND TOP OF WALL CON1. TRIAL 1R /A FLUSH IC TILE �- - -- ACOUSTICAL BLANKET • 501/0 UALL 5/8• GYP. BD 'TYPE 'X' • FIRE RATED WALLS. - -. PCLLDER DRIVEN A`•40R6 • 24 CAULK GYP BD. 'O FLOOR • ALL SOWD AND Nat WALLS DEEP LEG TRACK S_.-'IDN FLOOR W 3 - 1 5/8° SCREWS • 2'- D' O,C DEEP LEG 15 2'. TYP cF ICE WALL FRAMING BEAU ABLATION b' • 20 GA STEEL STUDS • 24"00 FULL HEIGHT W/ DEFLECTION TRACK .HEAD • ROOF 5/S' GTP, BD. EACH SIDE SILL BELOW — DEEP LEG TRACK ATTACH • SILL AND CEILING - DO NOT ATTACH GYP BD TO TRACK STEEL 5710 ATTACH GYP BD. 'EC TI ON Cl/ S UDN END OF PARTIAL HEIGHT WALL SCALE 1 1/2' = /' -0' SECTION RECENEo cmDFTUKw ■GG � 1298 PERMIT CENTER • • 4 O N Ui 0 Q 1 EE N6— O ILI Lui., ®®D hl ▪ Q � cc ®O 0 • ZO Z °W O la ▪ W O: z S ( ▪ LtJ mom— TA— 2