Loading...
HomeMy WebLinkAboutPermit D98-0303 - MAGNOLIA HI-FI AND VIDEO - CEILING AND SOFFITSD98 -0303 16600 Southcenter Parkway. Magnolia Hi -Fi and Video City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9137 Address: 16600 SOUTHCENTER PY Suite No: Location: Category: ARET Type: DEVPERM Zoning: Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: .0 South: Sewer: Slopes: Permit No: Status: Issued: Expires: D98 -0303 ISSUED 09/30/1998 03/29/1999 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERS /AFA .0 East: .0 West: .0 TUKWILA N Streams: Contractor License No: TMCON *195VC OCCUPANT MAGNOLIA HI -FI AND VIDEO 16600 SOUTHCENTER PY, TUKWILA WA 98188 OWNER CAPITAL & COUNTIES USA INC Phone: 415 421 -5100 101 CALIFORNIA ST #2525, SAN FRANCISCO CA 94111 CONTACT LARRY CROSS Phone: 206 - 285 -4300 701 DEXTER AV N, SEATTLE WA 98105 CONTRACTOR T M CONSTRUCTION CO PO BOX 20820, SEATTLE WA 98102 * * * **** ** * * ** * ** * * * * * * * ** k************************** * * * * * * * * * * * * * * *** * *** * * * * * * * * *, Permit Description: INSTALLATION AND ALTERATION OF EXISTING SUSPENDED CEILING /SOFFITS TO MATCH EXISTING ADJACENT SUSPENDED CEILING. **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *, Construction Valuation: $ 25,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N . Moving Oversized Load: N Start Time: End 'Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N . Street Use: N Water Main Extension: N Private: N Public: N *************************************************.**** * * *• * * * * * * * * * * * * * * * * * * * * * * * * * *, TOTAL DEVELOPMENT PERMIT FEES: $ 650.06 *************************** * * * * * * * * * * ** * * * * *• * * * * * * * * * * *** * * * * * * * * * * * * * * * * * * * * * * *, Permit Center Authorized Signature:��Lt�- y -�.�.� Date: 9P'2C1—�� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature:___ �_ i s__ Date: 9 -2s Print Name: _'2t A) � G This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 16600 SOUTHCENTER F'Y Permit No D98-0303 Suite: Tenant: Status: ISSUED .Type: DEVPERM Applied: 09/03/1998 Parcel #: 262304-9137 Issued:. 09/30/1998 ************************************-k**************1(*********************** Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and theJukwi:la_Building Division. Electrical permits sha.1.0e::'ob0)ned.t6:toaa11 the Washinaton State Division of Labor and IndustrieS-and:Tall elect rical work will be insetted by that agency (24.8=66'.30:-:. All permits, Inspection records, and approved plans shall be available at the job site'pridr:.t0 the start :Of any,00n- .struction„:,,These,documents are to he maintinedand.:avail- able untily.final inSpection approval' is,granteth 4. All construction to be done in:conformance,,with plans and reabirements of the'liniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997.,EditiOn),., and WaSbington State EnerciV.:Code (1997 EditionY. . Validity Of -Permit. -The issuance of a permit orapProVal OT plans speCificationsand cOMputations shall not be oOn strqfed tLI be a permit for -o an approval of, any violation of ',any of the,provitlensof.the bui:idfng code or of.,,any., other ordinanbe of theiurisdictio)!J . No O mi t presuMing0.6 giVeauthority.:to violate or cancel the provision. ot this code shall be valid .. • CITY OF TUK'IIILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: 1\A Ac; Kip Ll4_ Ni-f l 2. NlD, rr) Value of Construction: 26,000 Site Address: �- City State /Zip: 1(c (c O() �, K 'i�Ca�i' I L.&I ILi., _1> Ji Tax Parcel Number: 2.6 Z3o y - i'i 31 Property Owner: �tAL Pf�-,T -T` �xl I NC- Phone: Street Address: City State /Zip: 1n1 (JLw CIA =� / -20i1L 275, To .��v t .� Fax #: Phone: , Area of Construction: (sq. ft.) 1 ) 7 Cjc)�y Contractor: r j Ia M1. `.i%J�.6; KACj L.)I) c'o , Street Address: City State /Zip: Fax #: Architect: (<7,,//:,\14-1r-' l� `'� - c Co - Phone: . eie-c5, L� 6 Street Address:CityState/Zip: Fax #: Engineer: NA Phone: Street Address: City State /Zip: Fax #: Contact Person: /� n `; _ y�' %) �, y {� 1AT.A�1- (-4.c ' / 4��F t N) e_y1,6 -OL 1�,11l('' \' Phone: lJ / r /_,06,-. L ` -✓ I-)Wl Street Address: __ 1 City State /Zip: Fax #: ascription of work to be done: Description LktlD ►J . 1 j M10 tO , - [5,1- c ll'' . Cpl J ) , ' /Ai T , v -0-1 :. ST, A. AV- > ..'. _ ) - Existing use: a Retail ❑Restaurant ❑ Multi family ❑Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑Office ❑ School /College /University ❑ Other Proposed use: Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑Other Will there be a change of use? ❑ yes �no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes �no Existing fire protection features: .� sprinklers Prautomatic fire alarm ❑ none ❑ other (specify) Building Square Feet: C, )28'2) --2T-- existing , Area of Construction: (sq. ft.) 1 ) 7 Cjc)�y �}= Will there be storage of flammable /combustible hazardous material in the building? El yes dcl no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shal be extended more than once. Date application accepted: x[ // Dale application expires: Applic i taken by: (initials) CTPERMIT.DOC 1/29/97 LEASE'SIGN. BACK.OF APPLICATION-FC •L COMMERCIALJMUL:TI ILY TENANT IMPROVEMENT /AL. RATION PERMIT APPL/CATIbNS' MUST BE SUBMITTED-WITH THE FOLLOW.ING'. A'LL IIRAWINdS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED NIA SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ® Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Properly lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ®1I ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR-AUTHORIZED AG , Signature: L� Date:c _ b . J U ft v Print name: j uu) c_____ \rt PQnn 265-1-1350 Fax #: 1,64 0,6 8S vs1 ) q / Address /C)I - A y;n} t GTAT City /State /Zip CTPIiiRMIT.DOC 1 /29/97 • • ++++A++++**k+A+**a+*A*+**+*f+A+*+++N****A**A*+Ik+**+*+*+*a*+++**+ [I\Y OF lUK#ILA. NA . TRANSMIT ^hA+*A+*oa++++**++**A**+++**A+*****+++*+a******A++*+**+A+*+a+A** TRANSMIT Number: R9700839 Amount: 395.75 09/30/9B:10:29. Payment Method: 13714 Notation: OLYMPIC ASGOC • InitT-TKF Permit No D98-0303 Type: DEVPEHM DEVELOPMENT PERMIT Parcel No 262304-9137 Site Address: 16�O0 SOUTHCENTEK ' . ' Total fees: 650~06 This Payment 395.75 Total ALL Pmts: 650.06� : • Billancpn - .00 ^**Ai:*«++A*+*�aItA*++*Aa***ic***+***1%+^*A*«aA+**a****a+*A**+++*a+ Account Code 000/322.100 000/386.904 ` Description DUILDING - NONRES STATE BUILDING SURCHARGE ^ Amount'� � 3g1.25' 5 6288 09/30 9717� � TOTAL.' 395"75 .`,� ` � � +��*�*+*x*�A****+*�*«***Ata�^aa�*�*+a*+**h�*+***.^+,+Aa+4*+«+^��� :IT/ OF TUXNILA, NA' . ' ` � ' . ' ,``' `� TRANSMIT'` ���/*A,A*A*+*+++x*+A�*A+*+*+A**k*++***IA*4*a*A��+�**+a++*+�*: TRANSMIT Number: R970O826 Amount: 354.31 09/O8/98:16:03.: Payment Method: CHECK Notation: OLYMPIC ASSUCIAT Init: DLH • Permit No: D98-0303 Type: DEVPERM .DEVELOPMENT PERMIT' Parcel No: 262304-9137 Site Address: 16600 SOUTHCENTER PY. • Total Fees: ` 254.31 Total ALL Pmts: This Payment Account Code 000/345.830 650.06 254.31' �Bm1unce: • • 395^75.' a:A**` Description ` �' '. ''Amount . ' PLAN CHECK - iNONHES ' ' ` �'� , 254,31 ' � � � �� 254.31 _- ! - 09/10 . | .� TOTAL � INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 i8 INSPECTION RECORD Retain a copy with perI Pc(i-o3a3 PERMIT NO. (206) 431 -3670 Proi�c�t: VIac-fa. f-r'1 F 64 v ; A Ty•e gfriinnspe io u Address. I ' (a bo Se-1, .� 0/ Da : Special instructions: Date wanj d / �/ !� �/ QD .m. Requ er: , 111 r^ , C 0 )I VI J 02,1t. Phone .aoc X86 ~339c �►�� 4 pproved per applicable codes. ' s7� War Corrections required prior o approval. COMMENTS $42.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECOR'-i•1 Retain a copy with o3Q3 PERMIT NO. 206) 431-3670 Project:87,42.Th_ Type of Inspection . Fly, Date cilleil; , ,14 fi UP -,/ 10 Addrertio 00 s,01.46 eavtater goy Special instructions: . Date wirletlqqg a.m. C15-Fri- Requester., r rosii-A-31eV PhQne No (aQ .5--is-os- i riy, eis4-3.9 Approved per applicable codes. '.Corrections required prior to approval. 6/ COMMENTS: A (.- / /-L/4 -6_, /e-ea 7)64€97- 00 CoryzA E_Le. 7 (.7„40-->e------"q i7( (9 77 alA/i-e--- 6 /iz6 (,_if, 70,„ ---K/c/C,cr7,(5,(1' , 14 / , Date: pi $42.0 r REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORrs Retain a copy with per -..1 1)95-.66 3 ` PERMIT NO. (206) 431 -3670 Projects 4& 7 4 /-%1 f 1 Type of inspection: Adv&� Sc. /0,4-,-e-e47, // , Date called: Special instructions: Date wanted: A G f0 / / a.m. p.m. Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: &i: G.e55 r I $42.00 REINSPECTION FEE REQUIRED: Prior to i spection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project Address City of Tukwila Fire Department r r• t :777 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Thomas P. Keefe, Fire Chief Permit No. 51!)- 03°3 Name icily-)0 (1c, \,..k\ (.0(9C) CY_A-11"\ C-sz Y‘ Suite # Q. Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: 510 (02N\11216. Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: [206) 575-4404 • Fax (206) 575-4439 1994 Washin•t. State Nonrecllential Ener. Co4Com•liance Form Lighting Summary: '994'.yasmngton irate Nonresiaent171 E'ergy :Jae Camphorate ,-o,mS -SUM Aonl 1994 Project Info Project Address es ,/t F( .,n # u.,, LA Date �� CD r��,.,� For Building Department Use rY t AT / .mac L.. t c if rt,t)f AS_e-pDC_ C .c-t fr1MfI2y • , • Applicant Name: [ OLyypr Applicant Address .�e, Applicant Phone (2r ,) 2_6 -V 3 Project Description ❑ New Building ❑ Addition ❑ Alteration Compliance Option ❑ Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over) Indicate Prescriptive 8 LPA spaces clearly on plans ) Alteration Exceptions (check appropriate box) ❑ No changes are being made to the lighting ❑ Less than 60 % of the fixtures are new. and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) Location (floanroom no.) Occupancy Descnption Allowed , per R' " Area in ft2 Allowed x Area ' Watts Proposed • _ !� - d. 0.2 W /ft2 Open Parking 0.2 W /ft2 Outdoor Areas .._ 0.2 W /ft2 — Bldg. (by facade) 0.25 W /ft2 Bldg 1by perm) E.►J1>�l�*J _ [ ?, Note for building exterior, choose either the facade area or the penmeter method. but not both) To Allowed Watts " From Table 15 -1 (aver) - document all exceptions taken from footnotes Total Allowed Watts t32,.5—, Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Intenor) Location (floor/room no.) Fixture Description Descnption Number of Fixtures Area in ft2 (or If for penmeter) Watts/ Fixture Watts Proposed 0.2 W /ft2 Open Parking 0.2 W /ft2 Outdoor Areas .._ 0.2 W /ft2 — Bldg. (by facade) 0.25 W /ft2 Bldg 1by perm) E.►J1>�l�*J _ [ ?, Note for building exterior, choose either the facade area or the penmeter method. but not both) To Allowed Watts /e... 1 a a IMW4 4iNci!- ♦ ) . A . i IIMMI111 Total Proposed Watts may not exceed Total Allowed • a s for Interior Total Proposed Watts Maximum Allowed Lighting Wattage (Exterior) Location Descnption Allowed Watts per ft2 or per If Area in ft2 (or If for penmeter) Allowed Watts x ft2 (or x If) Covered Parking 0.2 W /ft2 Open Parking 0.2 W /ft2 Outdoor Areas .._ 0.2 W /ft2 — Bldg. (by facade) 0.25 W /ft2 Bldg 1by perm) 7 5 W/If Note for building exterior, choose either the facade area or the penmeter method. but not both) To Allowed Watts Proposed Li hting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) Location Fixture Descnption Number of Fixtures Watts/ Fixture Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Proposed Wattsq,�j C4966." (tce 1994 Washin•t, State Nonresidential Ener. Code Com•Iiance Form Lghting.::Summary '994 ',tr aSntngton State Nontevacetut E -ergy :ooe ComouanCe , ornis April 199.4 Project Info Protect Address LE_><LA 14 I - I Tibt Llt LA F. l�f Allowed Watts per ft2 " Area in ft2 Date (,)n { 0 ^yy_� For Building / Department Use il015l A • •. A -_ -. a A i7 0 �. 4 a - - Applicant Name: t q lb ,r i VApr� "C. ^(:. l ' 1c"")(7-2 n t1E Applicant Address Applicant Phone C 1( l 2- Eer __q e,6) Project Description ❑ New Building ❑ Addition Alteration Compliance Option Prescnptive ❑ Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over) Indicate Prescriptive 8 LPA spaces clearly on plans ) Alteration Exceptions (check appropnate box) ❑ No changes are being made to the lighting - Less than 60 % of the fixtures are new. and installed lighting wattage Is not being increased Maximum Allowed Listing Wattage (Interior) Location (floor/room no.) Occupancy Descnption Allowed Watts per ft2 " Area in ft2 Allowed x Area B -_ -. a 11111M11111111 lll11110=.111l12=i ti i7 0 �. 4 a - - ---- - - - - -- - j�Jt�t•ttrt►r- C Total Proposed Watts may not exceed Total Allowed Watts tor Extenor Total Proposed Watts — From Table 15 -1 (over) - document all exceptions taken from footnotes Total Allowed Watts '5z 6—v Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Intenor) Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed B -_ -. a 11111M11111111 lll11110=.111l12=i ti i7 0 �. 4 a - - ---- - - - - -- - j�Jt�t•ttrt►r- C Total Proposed Watts may not exceed Total Allowed Watts tor Extenor Total Proposed Watts Total Proposed Watts may not exceed Total Allowed Watts for Interior --• Total Proposed Watts & Maximum Allowed Lighting Wattage (Exterior) Location Covered Parking Descnption Open Parking Outdoor Areas Bldg. (by facade) Bldg (by perm') Allowed Watts per ft2 or per If 0.2 W/ft2 0.2 W /ft2 0.2 W/ft2 0.25 W /ft2 7 5 W/tf Area in ft2 (or If for penmeter) Allowed Watts xft2 (or xIf) Note. for building exterior. choose either the facade area or the penmeter method, but not both) Total Allowed Watts Proposed Li htin Wattage (Exterior) (May not exceed Total Allowed Watts for Extent) Location Fixture Description Number of Fixtures Watts/ Fixture P Watts GG�� oP �ff k C Total Proposed Watts may not exceed Total Allowed Watts tor Extenor Total Proposed Watts PL��REV1E �OU�TIN��SLIP ACTIVITY NUMBER: D98 -0303 DATE: 9 -8 -98 PROJECT NAME: MAGNOLIA HI —FI AND VIDEO xx Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter Revision # After Permit Is Issued DEPARTMENTS: 5 Bui inrDivision 1.-10-V6 Public Works YVw F re /OD Prevention Structure ,, j Ll 'vim Planning Division iyo,n Permit Coordinator if DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 9 -10 -98 Complete ljel Incomplete n Not Applicable ❑ Comments: TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 10 -8 -98 Approved Approved with Condition Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: Approved DUE DATE: Approved with Conditions n Not Approved (attach comments) REVIEWERS INITIALS: DATE. \PR•ROUTE.DOC 6/98 City of Tukwila Fire Department Fire Department Review Control #D98 -0303 John W. Rants, Mayor Thomas P. Keefe, Fire Chief September 14, 1998 Re: Magnolia Hi Fi - 16600 Southcenter Parkway Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 ,gam - 052.000 (tU97) Detach And Display Certificate DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 TMCON * *195JG 01/01/1999 EFFECTIVE DATE 04/07/1981 T M CONSTRUCTION CO PO BOX 20820 SEATTLE WA 98102 RECEIVED CITY OF TUKWILA SEP 3 0 1998 PERMIT CENTER - .� Detach Arid Display Certificate N 89 45' 58" W 257.62' SOUTH LINE PARCEL B ' - NORTHLINE PARCEL C gOUT!( LINE P RCEL III NORTH LINE PARCEL IV J NGi N 0 02' E 114.00' - N 89 ° 45' 58 W 321.57' } N 89` 5 2.05 L ✓ °IJ��L�.�. — o l00 < ' -- N 0'14' 02 22.50' N 89 19 W 619.81 NI PI414.02 era, 16 hlu. ^G2G t9 ern e, a i '3 .. VI;CINITY,'MAF GALL. DE OM, 01x15' - u ?9,f(K N!G t.'II (H I -IA.\1 - 'v 6 /KTAI 2 0-1 (0. ;2,2 x 2.5) = To °UIF�90 lo'4I._ ALkIrA��� of SI1'% - , FILE COPY N' U -V.l-4 15 t F> I..' • OK^- 1_4N ,5 Y' 5 0< Af`eA of ''. I, 1,1 e Stii,ott ;c c.:: o c::< omiscionc a9J '0.'J ci dcco not authorize the violation of Cny adcpted code or ordinance. Receipt at contractoria copy of approved RIMS aCmowied By Permit No SEPARFFE r rrrr REQU.RED G.,: r 0 MECHANICAL L✓ ELECTRICAL 0 PLUMBING 0 CAS PIPING CITY OF TUKVV :LA BUILDIN3 DIVISION 0 5- 20 -97 . ti 91s55 EGISTERED CUIT ARC.kIiTECi LAY y .CROSS i E OF 001 MOO Y OF'TUI(WILA APPROVED SEP 16 to h r u 11.1ILIIDING Ci llriSlON CIT DECEIVED SEP - 81998 puorr CBNIER Mso3o3 SITE PLAN STRANDER BLVD (S 164TH ST) N 89 ° 45' 58 W 675.05' SCALE: 1 ° - 30' rceis I a. IL of doun a aJ., 0 , 6LA 1 Y5. recdr.:te oder AeM Ctn9 Na.'79:01806 1 h'�:9 a revision of Short. Plat No. ])- { 30634 A. ..cis d g III , he a ..l - Section 26, ioneship Stitch, 2J fla h a East; A n9 follows) Beginning I P S Street); mid fast parallel et. the ectursent, t lone of of DO.D. feet to on intersection oth tsutn :ors. of mid 5tranhor f000l'earci, and the true point of mg... of the ',sin iosoi Doeo sta.; South thsnce contonuing , sal lel .a„ so is - n -n. a dis tante of MAO feet cu moment. last if, of sate zo the rionterentee Southeast come" of said solidivismn; the., tor. distance ' 0 . hest fait wc maroon, n distance of ..-. thence feet a mint of cosset a rcalc.. fees mrough o s of Di 5D' a nistahne of Strander goolivarM ',pence ...II S n t feet to the ime mint :on. nommentation established Sy the 5ith . Me (mho. no .; 2-fi , OM. . o et Man a. fro A. '9 SEA( ■2115 )fi5_. wIF. 61 :4 S13S UrR '1 J' a f PARKWAY SQUARE MAGNOLIA HI—FI TENANT IMPROVEMENT BUILDING .A SOUTHCENTER PARKWAY TUKWILA, WA SITE PLAN 09 -04 -88 - :TI IMPROVEMENTS 00 -00 -00 PERMIT SUBMITTAL 97032 „ r =-tr OL TEM '.QTY COLOR / MOUNT - I - LAMP :., QTY ' COMMENTS 8 -0 k-CC DUO IIINIE OIRC4 T TI¢4CK. UNITE 2 SUSPENDED 6 )0C E 18 *1 G TC SUSP ENDED CEILING, M^1e CN E %18TM. TO RUNNERS IS TIAT, EXISTING R / 4TC4 E s TRdCK9 AND rIYNR , AC-FARE/3 TO NAVE 6 INDEPENDENT DIMMER SWITCH 1- r ex ett4 6' 0 LONG DJO WHITE CIRCUIT TRAN/C d RECESSED 2'X2' R_BDIRESCENT i-IMIIRE. WIT4 2 TUBES 13 UNITE 2 LA - -IN .. STOCK . 2 .L. 141, T - 32 a 20 I HATCH ECISTN. I AA CJ 0 VEI I 3” D. PARABOLIC LOUVERS FLUCR, DGVNLITE 'LTTECASTER` WITH CLEAR Ai-ZAC II1ASP 13 CLEAR ALZ4C 2 RECESSED - L40R =no new ]9 23 LK: ITOLIER (201) 864 -3609 001511E 4ALtX£N 32 NALIX+EN 1 .30L'. 32 AWL 3 � RECESSED hcANDESOEN* T_W I 28 (5 j T' P'E SYSTEFI SNOT.. NEW P /EPEDEn -, AR B Pe N D G ED 1 -RAR E ^ .1lMTPE .CTWALL N SOLN:. ECOM ". EXISTING- '. NC CHANGE I s+ss REGISTERED: ARCHITECT UR l T Ep X CROSS '0SI11NGTON SCOT` S OUNDROOM RELFECTED CEILING & SCALE 1/8" = CEILNCI SC EL.IJLE 1 RID OLCR COLOR - SOURCE 0 :f'ENTS AFF SEE 0400 9 -E 3 500 SC 0D pANT NA DRYWALL A 1 ,1[3I BOUE' w - E ' 111r/ft &. nnI E Y DRTWALL �3 E6PIT - E>C1 - ., sc.PIT PAT+. 1 0 SF:-A`r SFWCE ORE IF LOCKiNC{ CL P RUNNER TO AIN Rl 3.NE$e 9P'LIC o A N TE k2SEE TIONC OF RUNNERS ,SHALLBE 4T4 HED MEC 11NIG4 TNT ER.L CKING. CNNEG IONS..',. 3 OW 4 h OP ?SIVE1 SCtREWS PINS PLATES WI H MENT FGIOTHEf2 4F" ROVED CONNECTORS. ONNE TORS r.QR 2 /.` LOAD OR uL71h1 + E TENSION OR OOMPRESSICT I I"'\ MIJE'" 6© ROUNDS -: EX•5T'4G LIGHTING PLAN ■US I ,. T L.I "EXISTING WAREHOUSE - -NO CHANGE 1 11 I EXISTING WATTAGE = 15,553 WATTS NO 9NCREASE IN EXISTING WATTAGE LI�NTINCT SCHEDULE - '!NO INCRE45E IN iU47TAC2E) LEGEND NEW CEILING C===] SOFFIT TO BE REMOVED LIGHTS TO BE DEMO I NEIL LIGHT FIXTURE TO MATCH EXISTING "IL.NAGLI;f[ NI DEXTER AVE- N. Y.81Tl. -_, WT 98109 20E- 285-- 4300 C M P MAGNOLIA HI -FI & VIDEO 16600 S. CENTER PKWAY TUKWILA, WA .VERT. STRUT E12 ..y'OC. ACOUSTICAL PANEL CONT HORIZ STRUT TO PREVENT SPREADING OR RJNNERS P_NDEC'CELVNG DETAIL AT WALL' HANGER WIRE ALOWI TENSION • ? I 110 2R5 IC 300 WALL TRI giNtsg 45 , EXISTING 42' DEEP TJL ® 36" EXISTING 3 '2 METAL STUD SRACNG TO ROOF DECK EXISTING 1;2' 0.58. PLYWOOD NAILER -i- SUSPENDED TILE CEILING NEW SUSPENDED TILE MATCH L L L CELL ING �TO EXISTING DOM,O SOFFI' 4 I SO I FFIIT REMOVAL I I CITY Of TU6WITA APPROVED TEP I6 135 . E CITY RE OF T U K'AI IIA V IIUI 11 I ,cv 5EP I'. 119 98 PERMITCEMER 4F 11K VPOPwn a arvan' Mm 9.r. W i Uiu Nm m x � W vlp.Ei° N rwr wMaR wlpllFx umnN�tlw f! d 115wcNiLti w2 9_I Re SD+E Tla'' ]a' 9703'2 ✓Uf.BB ' JfSlfi LN4N11 � ' � 144411/ 00 -00 -08 PERMIT, SI18MITTAL . "NUN RNNER HANGER WIRE NOT TO EXCEED REFLECTED CEILING & LIGHTING PLAN