HomeMy WebLinkAboutPermit D98-0306 - PRIMESOURCE CORPD98 -0306
355 Treck Dr.
Primesource Corp.
City of Tukwila t'
(206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
DEVELOPMENT PERMIT
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES,
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
Parcel No: 022340 -0042
Address: 355 TRECK DR
Suite No:
Location:
Category: AWSE
Type: DEVPERM
Zoning: TUC
Const Type: III -N
Gas /Elec.:
Units: 001
Setbacks: North:
Water: N/A
Wetlands:
.0 South: .0
Sewer: N/A
Slopes: N
Contractor License No: JOSEPSS153JD
OCCUPANT
OWNER
CONTRACTOR
CONTACT
ARCHITECT
Permit No:
Status:
Issued:
Expires:
D98 -0306
ISSUED
10/20/1998
04/18/1999
Occupancy: WAREHOUSE
UBC: 1997
Fire Protection: SPRINKLERS
East: .0 West: .0
PRIMESOURCE CORP
355 TRECK DR, TUKWILA WA 98188
PRIMESOURCE CORP
15 TWINBRIDGE DR, PENNSAUKEN NJ 08110
JOSEPH S SIMMONS CONST INC
P.O. BOX 9089, SEATTLE, WA 98109
JOE SIMMONS
3223 NE 125TH, SEATTLE WA 98125
LANCE MUELLER & ASSOC
Streams:
Phone: (206) 575 -1500
Phone: 206 281 -7227
Phone: 206 -362 -7227
Phone: (206)325 -2553
130 LAKESIDE, SEATTLE, WA 98122
*************************************************** * * * * * * * * *kk* * * ** * * * * * * ** * * * * * **
Permit Description:
REMODEL AND ADDITION TO OFFICE AREA TO INCLUDE
FLAMMABLE PRODUCTS STORAGE ROOM WITH AND OUTSIDE
ASPHALT EMERGENCY OVERFLOW SWALE.
**********.***************************.************* * * * * * * * * * * * * * * * * * * * * * ** * * * * * * **
Construction Valuation: $ 75,000.00
PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: JJS
Curb Cut /Access /Sidewalk /CSS: N
Fire Loop Hydrant: N No Size(in): .00
Flood Control Zone: N
Hauling: N Start Time: End Time
Land Altering: N Cut: Fill:
Landscape Irrigation: N
Moving Oversized Load: N Start Time: End Time:
Sanitary Side Sewer: N No:
Sewer Main Extension: N Private: N » Public: N
Storm Drainage: Y
Street Use: N
Water Main Extension: N Private: N Public:. N
k************************************'*************** * * * * * * * * * * * * * * * * * * * * * * ** * * * * * **
TOTAL DEVELOPMENT PERMIT FEES: $ 1,380.44
k****************************************;********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Center Authorized Signature:_
Date: is-20
1f
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
cancel the provision of any other state or local laws regulating .construction
or the performance of work. I am authorized to sign for and obtain this
development permit.
Signatur
Print Name: ( "14∎4- 1.mo!`�
Date:
61?-0/?:
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
CITY OF TUKWILA
Address: 355 TRECK DR PerMit No: D98-0306
Suite:
Tenant : Status: ISSUED
Type: DEVPERM Applied: 09/09/1998
Parcel #: 022340-0042 Issued: 10/20/1993
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Architect or Engineer and the. Tukwila Building Division.
Plumbing permits shall be obtained through the Seattle-King
County Department of Public Health, Plumbing will be
inspected bv that agency, including all gaS piping
(296-4722).
3, Electrical permits shall be obtained thrOuall the Washington
State Division of Labor and industries and all electrical
work will. be inspected by that agency (248-6630).
4. All mechanical work shall be under separate permit issued by
the City of Tukwila.
5. All permits, inspection records, and approved plans'shal1 be
available at the job site prior to the start of any con-
struction. These documents are to be maintained and avail
able until final inspection approval is granted.
6. Any new ceiling grid and light fixtUre installation is —
required to meet lateral bracing i-eq6iisements for Seismic
Zone„: 3.
7. Partition walls attached to ceiling grid must be laterally
braced if over eight (8) feet in length.
8. All construction to be done in conformance with approved
plans and requirements of the UniforM Buildina Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition)
anci,WashingtonState Eneray Code (1997 EditiOn). •
9. Notify the City of Tukwila Building Division_prior to
placing any concrete. This procedure is in addition 'to any
requirements for special inspection.
10, Validity of Permit. The issuance of a permitOr approvalbf
plans, •specifications, and computations shalt'not be con-,V
strued to 'be a permit for, or an approva)of, any violatTon
of any of the provisions of the building code or:Al.+ any:
other ordinance of the jurisdiction. No permit presuMTng to
give authority to violate or cacej the pr)visions:Of'this
code shall be valid.
11. VENTILATION Is REQUIRED FOR ALL NEW ROOMS AND: ,SPACES OF NEW
OR EXISTING BUILDINGS IN COUFORMANCE WITH THE UNIFORM
BUILDING CODE AND THE WASHINGTON -STATE VENTILATION AND.
INDOOR AIR QUALITY CODE, CHAPTER 51-13 WAC.
12. 1*** Public Works 11**
13. Temporary erosion control measures shall be implemented as
the first order of business to prevent sedimentation off-
site or into existing storm drainage facilities,
14. APPLICANT SHALL APPLY FOR A DOUBLE CHECK DETECTOR CHECK
VALVE INSTALLATION UNDER A SEPARATE PERMIT.
PLEASE NOTE THAT PW WILL NOT SIGN OFF THIS PERMIT
UNTIL DDCVA IS IN PLACE.
CITY OF TUKV(LA
Permit Center
6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188
(206) 431 -3670
R:.STAFF':USE ONL
Project Number: ` rot
Permit Number:
0 *06
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Project Narl?� /Tenant:
-, _
Value of Construction: �=
Site Address:
5,C)--- T-2
City State /Zip;
CtC -) n_ fU> :i' �i-n - rl8i��
Tax Parcel Number:
Z )_ 0 -Ll
G i o 0 -1-
Property Owner:
Fiat rvi C
` ;.•, a(-- C- _
Phone:
Z06 :7c/ L/ - S _ (C L—
Street Address: City State Zip:
s 5-.ST ti i � -n•- - 0/2- 3e: Sri i4,14 1 /5 18
Fax #:
Zo �• s -7 .S- - 13 70
Contractor:
• J , -) or t I S
—
• 5 ;,-1,-,,,,_ co., 5 C.l'J >M4,11. / ti :I; L �.
Phone:
^7 r
2.0 -- 5 � G -` 7 L.: 'Z 7
Fax #:
•Z_�.�6- •3� 2_- D 1 i fY
Street Address: City State /Zip:
"z -Z- 3 i•,'�- 125 5c -. LA A- 9')2-S
Architect:
L-141\) CC,
Mit UI.-k-- c.(L ` A c� 0 C
Phone:
-2,06 3 Z S 2.-05 3
Street Address:
i ) (� (--
City.State /Zip:
"0-4- (�- �� i 0 C7' C t^ - (-1.'1'x- r/ ,Y / -1. 2
Fax #: ,
2/,'')G 3j Z • �c5 0 S y
Engineer:
Phone:
Street Address:
City State /Zip:
Fax #:
Contact Person:
p " l m nil c. -j" p�n.J M l,k i..'v I I-i'I LL
Phone:
. ? . , 6 L j f . Z _7 2 -2_ --/
Street Address: , City City State /Zip:
7.--?-3 .5 i') L. 12-S-- , 1,:.1'1- 6/ c3 v / 2)...5
Fax #:
ZO j L Z 0 1 V. g
Description of work to be done: F-`(),.v.,,,,, F: , L L: p,w OL., (..., S T c f1,-T f2-L .,)ice
12- tr:: 1.1^ -0 PC-L- ? AO v.) TV 6/c---c / C-C- X74-
Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family 71 Warehouse Ell Hospital
❑ Church ❑ Manufacturing ❑ Motel /Hotel 71 Office
El School /College /University ❑ Other
Proposed use: El Retail El Restaurant CI Multi-family Multi- family 1,11 Warehouse ❑ Hospital
❑ Church ❑ Manufacturing El Motel /Hotel 0 Office
❑ School /College /University El Other
Will there be a change of use? ❑ yes In no
If yes, extent of change: (Attach additional sheet if necessary)
Will there be rack storage? ❑ yes 53 no
Existing fire protection features: P: sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify)
Building Square Feet: FS 1 (‘-:'% � existing
Area of Construction: (sq. ft.) -2-g3 O Sf
Will there be storage of flammable /combustible hazardous material in the building? 121 yes ❑ no .61-704„...-0
Attach list of materials and storage location on se•arate 8 1/2 X 11 •a•erindicatin• • uantities & Material Safet Data Sheets
APPLICANT REQUEST FOR PUBLIC WORKS SITEJCIVIL PLAN REVIEW OF THE FOLLOWING: :. .
(Additional reviews may be determined by the Public Works Department)
❑ Channelization /Striping ❑ Curb cuUAccess /Sidewalk ❑ Flood Control Zone ❑ Hauling
❑ Fire Loop /Hydrant (main to vault) #: Size(s):
❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Storm Drainage ❑ Street Use El Water Main Extension 0 Private 0 Public
❑ Water Meter /Exempt #t: Size(s): 0 Deduct 0 Water Only
❑ Water Meter /Permanent # Size(s):
❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule:
❑ Miscellaneous
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Date application accepted:
CTPERMI'T.DOC 1/29/97
Date application expires:
:PLEASESICN: BACK.OF.APPLLCATION -:FORM...
Apollo tl n taken by: (initials)
At.!...'COMMERCiAUMULTI- 1LY TENANT.1NIPROVE.11/IENT /A RATION PERMIT APPLICATIONS
•
Ul T:B'E: SUBMITTED .INITH`TTHE FO OWING:
ALL CIRAWI14 S` TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
'STRUCTURAL f= .NG1141EER OR CIVIL ENGINEER
`r' ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ Complete Legal Description ,� S i °r' 2-
❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Four (4) sets of working drawings (five(5) sets for structural work), which include :
❑ Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of
use only)
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of
those, identify by size and species which are to be removed and saved
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change
of use only)
11. Location and gross floor area of existing structure with dimensions and setback
12. Lowest finished floor elevation (if in flood control zone)
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H-
9).
❑ Floor plan: show location of tenant space with proposed use of each room labeled
❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
✓ any hazardous materials; dimensions of proposed tenant space.
711 L!9 Vicinity Map showing location of site
❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over.
❑ 71. Indicate proposed construction of tenant space or addition and walls being demolished
El 173 Construction details
❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of
water supply to sprinkler vault with documentation from contractor stating supply Tine will meet or
exceed sprinkler system design criteria as identified by the Fire Department.
❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings.
VJ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
r--� land use or SEPA decisions.
I ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
O Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized fetter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING_OWNER OR AUTHORIZED AGENT:
Signature: _1/")
_� 1-,
— __
Date: L,7/ L� r�/
Print name: - 5 e -r A
5 S�
0, ;s
Phone:
�Z .� -LZ-)
F'ax #: 3,2 01)g
Address 3z.,^1,-.1
4: g
)2.4". N�
City /State /Zips 9T2 l
CTPERMIT.DOC 1/29/97
fc`i 4y';�:P a': `v u' fe,::,.,�a:c >:. �.r, r,.Y�7 r$���...sr �'A� �nrrr.,}sra <r.,•a �� -...
V
5r-1"; rte, , : ai' ,y nigi ? z- r: H.... ,•,u •n
• A*0.**A.• kA** * * * *:F * *i *sF* * *•k * ** ** *A * * *. *** *>k * *. ***** *• *** *** *A•h *.'.�: *�•
CITY OF r.uKWILiA. !+!A TRANSMIT
i**•.*****• k. A*** ic* A**- %+ *.k *A• * ***•* * *• * * *•iFA *, *k *kA*A**oF*+F * ** **A * * * *A*
TRANSMIT Nursier; R9700851 Amounts 8.48.25 10/20/98 12:45
Payment Methods CHECK Notation: JOSEPH SIMMONS init: f3LH
Permit Flo: D98'0306 Type: DEVPERM DEVELOPMENT PERMIT
Parcel Not 022340' -0042
Site Address: 355 3'RECK DR
Total Fpess 1380.44
This Payment 848. 5 Total ALL Pmtfsc 1,3.80.44
Balance: .00
*** A**•***.**** 0.**** A****** ** ** * * *** *•*** * *A *k*A * * * ** ** * ** *Air * **** *•
Account Code
000 /822.100
000/343.830
000/386 904
412/342.400
Description
BUILDING - NCINRES
'PLAN CHECK - UTILITY.
STATE BUILDING SURCHARGE
INSP FEt. 7 STORM DRAIN
Amount
8'18.75
10.00,
4.50
15.:00
6977 10/21 .9717 TOTAL.: 848.25;
4M'tz'''')-"rmlYPID7411%7;NI.'1,7117=1"":1•7!'.9" ,t71."4'17,7t1,
C) •
iA.k1 A.A...4-k*.*********A71101r44..V**A.kfr******;k*kkAA**A.****.4*A*******A*.**.k:
;ITV OF TuvwILA, WA • - TRANSMIT
*k***A4.1kh“.4—A****A*A*A4********A4
TR(MSMIT Number: P9700827 Athountn 5n.19 09/09/98 1E:02'
Payment Methodn CHECK 1!otationt'30SEPH SIMMON CO Initn :BLH
Permjt No: D98-0306 Typen'.DEVPERM .DEVELOPMENT.POMIT.
Parcel No: 022340-0042
Bite Address.: 355 TRECK DR
Total Feost.,
This Payment 532.19 TOtal ALL Pmt 32..19
343 3
A4*****AA*.s.k.A4,4**kli..*.A.**A**7%.140;4s1;4*-*****-A**AA*4*.***.itY.
Account Code DescriOtion:
000/345.830 PLAN CHCP; HOWIES
Amount
532.19
• •
••
• • . . •
..,•,
•
•
•■
•
•1
•,
•
• •
'•
•
•
•
■
•
•
....•
•
5549-09/10,9717-.. TOTAL-, , '532.19
INSPECTION NO.
INSPECTION RECORL w`
Retain a copy with perms -•''
CITY OF TUKWILA BUILDING DIVISION
• . 6300 Southcenter Blvd; #1.00; Tukwila, WA 98188
NS- 03o6
PERMIT N
(2 6)431 -3670
Project: Pri+ryl e Sou 1'Ce-
Type of Inspection: , , r F-i 11 A i
Address: 35.3 r K Drive
Date called: -29-q9
9
Special instructions:
Date wante :14 y j _ 30 ,�p c - a..; m..
� /
Request r: �
Doll or Renee
Pho :206x/362 -722.7
H Approved,or applicable codes.
Corrections required prior to approval.
COMMENTS:
17,21,eS ,we 6
14 s1
C 5 C&).
Inspector:
Date: 7.
[Ti $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid.
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectior'
Receipt No:
Date:
INSPECTION. NO.
INSPECTION RECO
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
PERM.-
206)431 -3670
Pr ' av
(e.
nspe lion. •
Addr ss• �
::
Special instructions:
Dat
n
d:
�
?
a.m.
p.m.
r
Phone:
pproved per applicable codes. n Corrections required prior to approval.
COMMENTS:
Dat
❑ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
Date:
I
INSPECTIO NO.
INSPECTION RECC)
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188
?g 0306
PERMIT NO.
(206)431 -3670
Proj c :
rr1M -6
ki�e�L --�
Type of Inspection:
}--1 c :
Ad res55.
7/t...Q1 Or.
Date called: 5/y 7
Date wanted: / 5/514, / .
Sp9ci 1 instructions: 17 /j'
I / _ I Q (
l�i'r
iL '
.J.Y7 e
Requester:. --,
Phone 0 0 --3&01 --7a� 7:
nApproved per applicable codes.
COMMENTS:
corrections required prior to, approval.
/47/ Off're
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must .e paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No:
•Date:
!0
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100,• Tukwila, WA 98188
•
t' 1
P RMIT NO.
(206) 431 -3670
Proje t:
it /Y� e/J 0-1/CA
v
Type of i spe on:
001% •
Ad a s;,
DDa afite calle, c
/98 2`,31
r
rt.,
Specr
ial instructions:
/
I o/ '`
1
:: � :
;
R6q ester
—,
Pho.
-x, 3lO2- =7 12
9
p`proved per applicable codes.
Corrections required prior to approval.
COMMENTS:
_ / 3 - .wort...
Fib aoO,e 7X 57
Insp
$ .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No.:
Date:
4'
'a',r :ivy.- .:eP3:•� ,.. ,";- '=r,., ��.•�..f�_..r�,...... _- -�.r -+
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
c5-050,,
PERMIT NO.
(206) 431 -3670
Project:
1 " i� ✓0 VWIL.
Type of inspection:
:rri Ji4W_Y,.
•ate cal ed:
Address: j
J
Special instructions:
Date wanted: W
a.m,
Requester: CYL (j
-
Phone NoA-D10—Q/7 _45i
pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
/90 Aft)
Inspector: Date/)2q
Ft $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
• 7:
\
INSPECTION RECORp-I
Retain a copy with pee.,)
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 98188
pcig-o3ob
P
IT NO.
Project: pri me 0
Jou rce....
Type of inspection:
swa 1 e- a rea-
Address: 3 55 Trec.. rsk
Date called:
Special instructions:
Date wanted: a.m.
11 —
,-21 q8 El?
Requester: Leon ar j
Phone No.: 206/917- 8851 Poll'.
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
/1,/z 3 46-
c-711 00 5-9k(c/4y.f- ,eprf,;--erx
me c/ 713 CC //I
Inspector: /444
Date: a 7z .5/*
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No::
Date:
'INSPECTION RECOOT
Retain a copy with pe
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 98188
613 -0306
IT NO.
(206)431 -3670
Project:
pYi me.
Type of inspection:
-storm ciratnae.
Date called: (.� , 17 _ G J
Address: 3 5 5 T're c: O V i ve.
Special instructions:
Date wanted: GAD C,
p.m.
l P.m.
Requester:
Leona rci
Phone No.:200171'85cl Pgle•
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
N/ehP rr'f- ono' /oo /r- /f
-, 71-
Pr., i 4,1 c` , Con-4, in ikter471--
5-1,c, -4. Li/ 7/
-fi7 ✓ e / 1N Ae a .SGHO% /t'i.,
s b'c ✓e.
r cwPryyn 9,
beery- 5lDc kille J -'o
Inspector:
Date: /2_,,,,,,x697/9v,
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 9818
PERMIT NO.
(206) 431-3670
PrrAdit ,l 9 I/1 eee -
Ty Aljgrz,p2.ion:
A dtes,s- 7-06..c e......,
Date called:
.
f-'..., ZG___-a-7a /40/577-6_ 64-,..0ey-Ae
Special instructions:
wait
Date /9
a.m.
p.m.
Reziehi:76,70.0
Phone No.:
Approved per applicable codes. ..[Corrections required prior to approval.
COMMENTS:
1 f9k. S feli9P•e* 00----
f-'..., ZG___-a-7a /40/577-6_ 64-,..0ey-Ae
A7-- ‘,e7.54ias
go xif51,& 617(_( re_cc707
(QeJ,c/ ,,( /...s ,A... —
-22 A/07- (07,6„‹..
Z,(67/7/7 - 7--r-ait
ce-geol/ co0b-- ,-.6 ..;
1 21__L7J7A
/ .
Ins or:
$4200 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
7 Date:
5
F� ;'�s+gim- w;w�c-��t+zf; r.fi.<'•+.<ry � i' n T±Mr`k7rrc- 't r�+r
y1 ;
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
?-7-113o.
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 98188 }(206) 431 -3670
Pr•'ect:
(,nlrsourr41 C p
Type tze,m4, r��ir
Date called:
.4:;1.--
Special instructions:
Date wante /r 1 ! ?5 x <'a,nL..
p.m.
Requeste : , /
t..!19.0.4•;.:tle. fParar(
Phon No.:
e .x(.9 ( — e5.3'9
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Inspector:
Date: /2"1/7...4*
$42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No.:
Date:
.e:,;, '^'n'Gt+%�� .-, x^ �' �` ��;... ra'. c? �.,. y..: .i•'i°"i'7"'x„�,x•:��1"'3:b�:;r aI�Y: Frr! h. F" �!. �T"" ' +..M.rtC,.- 'S:L�•S�'FC,r'r,.ri i zc;�?••;,;..'...... �, �.�..,,,..:�'i''�: i>1
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
Project l,,,,, I'>~.e.
Soo r
Type of i ecp tir�o :
/- T - g
Add re
�js_S
"ire'
Date called: /�jiL
((
Special instructions:
Date wanted: 12
15
a.m.
p.m.
Requester:UvV.(
®141e- , Ao er,,
Phone Nolo if, 9 I...7S
,r i — 07/6 - L°.4' b ,/
4-(/
pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
A/ -L/e. -
/- T - g
®141e- , Ao er,,
,r i — 07/6 - L°.4' b ,/
4-(/
5 WZ6 s+Ere,v, 5/
-f
49 7? 6 S / .._
Zic9j0 / .. 4rfori Poss. '6c_ .,,
Inspecto .
Dat,
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
1
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
vCITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
I6,,
I '4
4 140. D%
PERMIT
(206) 431 -3670
Pro to, :
r tYl' _11. -
Ty.- of in pection:
' - -i 6.
ts• --fi= k_
Date calleilZ / ,
Date wanted: I f c'
tom" /h/ el
p.m.
Special instructions:
Reques er:
Q
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Date:
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
,_t, °.s ,..1.r.w....,m^ . Z:r4i..1.41 mtgl..-, 7,11.TF,7. -r..s .. _,-.. r-,7. .if'. roir -.-r rr1 -.1'I. yi..=:71: :45''.N4- ry.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
Pro lik,
Type 4i ectioo:
�rr !� D�
Date a I
44/
IA-
Special instructions:
f _ 3, O .i
�/
Date wan
f'i�g
a.
p.m.
Requette a -3,.,, G� -..er�
�:)
Pht�e q r _
1S J 7
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
dz
fr-
.d /
Inspector
r'i $42.00 REINSPEC4f'ON FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
4
Date: .
Receipt No.:
Date:.
INSPECTInN NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
0
PERMIT NO.
(206) 431-3670
Project: r Vy., 0.4 SL,IiircType
of inspelifl: cum j
Date called: 0 /7- on- ge
Address:
Special instructions:
2■frir
0
Date wanted: i'll
t . .
Requester:
6 oKketi
ci ....w5
Approved per applicable codes.
COMMENTS:
Corrections required prior to approval.
J.
41-zi
f s 4 117 ~-3-4-1
7 fr-711
/-%
Inspector:
Date: 41r
1 $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
.!MfrN'.;on,,,c frrt".7kt.Yyw'^q`P„.,. 1' ,.:.vr; ...n...r!Rr+c; a. ^sL!v •
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila, WA 98188
117/-030(c
PERMIT NO.
(206) 431 -3670
ect:
(, (1 k -(56 vt'r (. 2
/
COY Y ;7
Type of 'rt ecjg�y�,, /� '' /
'' aJ C.�IJ�/
Address: �,._..
?SS i r eK
,ve_
Date called:
ti /l /it
Special instructions: r
Date wanted: m.
11/11/9e
p.m.
Reque,stex: G t (or ':."(le.:( 2
Phone No.:
(-,)ca) 4) 1 - e.,W5 "1
Approved per applicable codes.
I
Corrections required prior to approval.
COMMENTS:
FAA-1146- e ocric.G. IWAir
Inspec
Date:,
$42.00 EINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
Receipt No.:
Date:
;.a
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
-11 i
PERMIT NO.
(206) 431 -3670
Project: \
yc 4 y-Q- SOU «2...
Date /f ! /1
Type of inspectiox
L S U ct. 101-
Address35 5
(i Dr.
K-
Date called:
1
t% to
(
Special instructions:
Date wanted:\
�1
6
a.m. ,
�% P.m.
Requester:
Ku
v.1 Ale
r ; o..
(
c( (7- -«
Approved per applicable codes. ( Corrections required prior to approval.
COMMENTS:
t
G, /,l /Sl,40-1-72/
insP*ZaalkA
Date /f ! /1
(96
$42.0( REINSPECTION FEE REQUIRED. Prior to irpection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
096 -0450/o
/
INSPECTION NO.
;; '; ^ »�! ^Cwe`..: F�'K.., cat .�w?;r's,
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
P ofr41. i 5 (. 6
Type aion
Date called:
Agsst , , Die.
Special instructions:
Date wanted:
a.m.
, p.m.
Request
{/
44442)
Phone
'r-
9/ "7_ X35.,
Approved per applicable codes.
ff4
Corrections required prior to approval.
COMMENTS:
-151-0 r e6A -6x
Inspector
Date:
I $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
7777V.7737,
City of Tukwila
Fire Department
Project Name
Address
John W. Rants, Mayor
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
CP& SO \-.) •C C-jk.
3S5 Tr e
Permit
Thomas P. Keefe, Fire Chief
No. C_O 9 c3
- z■ (07
P16-
)1111LARetain current inspection schedule
Needs shift inspection
Approved without correction notice
Approved with correction notice issued
Suite #
Sprinklers: -5
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre-Fire:
Permits:
NT
Authorized Signature Date
FINALAPP.FRM
Rev. 2/19/98 T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57.5-4404 • Fax (206) 575-4439
07.10.98
MATERIAL AND QUANTITY
ESTIMATES FOR H -ROOM STORAGE
3z ...
c#�ia tt i 111fT i ATE
1,4- DIOXANE
ACETONE
ACETONITRILE
ALCOHOL
ETHYL ACETATE
ETHYL ETHER
HEXANE
ISOPROPYL ALCOHOL
METHANOL
N,N- DIMETHYLFORMAMIDE
PENTANE
TETRAHYDROFURAN
TOLUENE
XYLENE
TOTAL ESTIMATE
8
179
299
14
63
14
253
164
409
20
4
28
24
6
1485
DUE TO THE CHANGING NATURE OF OUR CUSTOMERS' REQUIREMENTS,
MATERIALS AND QUANTITIES ARE ESTIMATES AND ARE SUBJECT TO
CHANGE. ALL CHANGE IN MATERIALS WOULD BE SIMILAR IN CLASS
TO THOSE ABOVE.
'‘‘‘C
�detS�a
RECEIVED
'OFTUKWILA
SEP 9 1998
!'E M6T CENTER
BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
1,4- DIOXANE
REVISION BATE: DECEMBER, 1993
REVISION NO: 1
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800.424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME: 1,4-- DIOXANE MOLECULAR WEIGHT: 88.11
CHEMICAL. FAMILY: CYCLIC ETHER FORMULA: C4H802
SYNONYMS: DIOXANE, DIETHYLENE DIOXIDE, DIETHYLENE ETHER
DOT PROPER SHIPPING NAME: DIOXANE
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G. II
DOT IDENTIFICATION NUMBER: UN1165 CAS NUMBER: 123-91 -1
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM HG:
VAPOR PRESSURE AT 20 C:
X VOLATILES BY VOLUME:
FREEZING POINT:
VAPOR DENSITY (AIR =1):
SPECIFIC GRAVITY (H2O =1):
EVAPORATION RATE:
SOLUBILITY IN WATER:
STABILITY:
HAZARDOUS POLYMERIZATION:
APPEARANCE AND ODOR:
CONDITIONS TO AVOID:
MATERIALS TO AVOID:
HAZARDOUS DECOMPOSITION
PRODUCTS:
101.32 C
29 MM HG
CA 100
11.8 C
3.0
@ 20 C 1.034
(BUAC =1) CA 3
@ 20 C COMPLETE
STABLE
NOT EXPECTED TO OCCUR.
CLEAR, COLORLESS LIQUID WITH A SLIGHT ETHER -LIKE
ODOR.
HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
OXIDIZING AGENTS AND STRONG ACIDS AND BASES.
INCOMPLETE COMBUSTION CAN GENERATE CARBON MONOXIDE
AND OTHER TOXIC VAPORS. EXPLOSIVE PEROXIDES CAN
FORM AFTER STANDING OR UPON EXPOSURE TO AIR OR
DIRECT SUNLIGHT.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT(TEST METHOD): 12 C(TAG CLOSED CUP) AUTO IGNITION TEMPERATURE: 180 C
FLAMMABLE LIMITS IN AIR % BY VOLUME: LOWER L.IMIT 1.97 UPPER LIMIT: 22.5
UNUSUAL FIRE AND EXPLOSION HAZARDS: VOLATILE AND FLAMMABLE. CAN FORM HEAT
SENSITIVE PEROXIDES WHICH COULD EXPLODE
DURING CONCENTRATION OR EVAPORATION,
PAGE 1
. r ^
�
EXTINGUISHING MEDIA:
SPECIAL FIRE FIGHTING PROCEDURES:
IV. HAZARDOUS COMPONENTS
1,4-DIOXANE WT.% CA 100
V. HEALTH HAZARDS
CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL
FOAM, WATER MIST OR FOG,
WEAR FULL PROTECTIVE CLOTHING AND SELF-
CONTAINED BREATHING APPARATUS. HEAT WILL
BUILD PRESSURE AND MAY RUPTURE CLOSED
STORAGE CONTAINERS. KEEP FIRE-EXPOSED
CONTAINERS COOL WITH WATER SPRAY.
TLV 25 PPM (SKIN) CAS NO. 123-91-1
OCCUPATIONAL EXPOSURE LIMITS CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
OSHA TWA 25 PPM
STEL NOT LISTED OSHA/NIOSH 2,000
CEILING NOT LISTED
ODOR THRESHOLD
ACGIH TLV-TWA 25 PPM (SKIN)
TLV-STEL NOT LISTED NSC 150 PPM
NIOSH 2.7-170 PPM
NIOSH NOT LISTED
30-MIN.CEILING 1 PPM
CARCINOGENIC
1,4-DIOXANE IS LISTED AS A PROVEN ANIMAL CARCINOGEN BY IARC, AND NTP. 1,4-
DIOXANE IS LISTED BY ACGIH AS A SUSPECT HUMAN CARCINOGEN.
PRIMARY ROUTES OF ENTRY
1'4-DIOXANE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE/SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE IRRITATION, HEADACHE, DIZZINESS, DROWSI-
NESS, AND NAUSEA. 1,4-DIOXANE IS EASILY ABSORBED THROUGH THE
LUNGS AND CAN CAUSE DAMAGE TO THE LIVER, KIDNEYS, AND CENTRAL
NERVOUS SYSTEM.
EYE CONTACT:
SKIN CONTACT:
LIQUID AND HIGH VAPOR CONCENTRATION CAN CAUSE IRRITATION.
PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE IRRITATION AND
DERMATITIS THROUGH DEFATTING OF SKIN. ABSORPTION THROUGH THE
SKIN CAN PRODUCE TOXIC EFFECTS.
INGESTION: CAN CAUSE GASTROINTESTINAL TRACT DISCOMFORT, NAUSEA, AND BLOOD
DISORDERS.
EFFECTS
1,4-DTOXANE IS AN EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY SKIN IRRITANT, AND
CENTRAL NERVOUS SYSTEM DEPRESSANT, NEPHROTOXIN, AND HEPATOTOXIN, ACUTE
EXPOSURE CAUSES IRRITATION, HEADACHE DIZZINESS, AND NARCOSIS. CHRONIC
INHALATION EXPOSURE CAN PRODUCE DAMAGE TO THE LIVER AND KIDNEYS, AND BLOOD
DISORDERS.
PAGE 2
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS WITH DISEASE OF THE BLOOD, LIVER,
KIDNEYS, CENTRAL NERVOUS SYSTEM, AND THOSE SUSCEPTIBLE TO DERMATITIS.
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING. IF THERE IS NO PULSE,
ADMINISTER CARDIOPULMONARY RESUSCITATION (CPR), CONTACT
PHYSICIAN IMMEDIATELY,
EYE CONTACT: RINSE WITI•H COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
GET EMERGENCY MEDICAL ASSISTANCE.
SKIN CONTACT:
FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES,
WASH CLOTHING BEFORE RE -USE, AND DISCARD CONTAMINATED SHOES.
GET EMERGENCY MEDICAL ASSISTANCE.
INGESTION: CALL. LOCAL POISON CONTROL CENTER FOR ASSISTANCE, CONTACT
PHYSICIAN IMMEDIATELY. NEVER INDUCE VOMITING OR GIVE ANYTHING
BY MOUTH TO A VICTIM UNCONSCIOUS OR HAVING CONVULSIONS..
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL. VAPORS EXCEEDING THE PEI.. AND TO MINIMIZE
FIRE HAZARDS. THE CHOICE OF VENTILATION EQUIPMENT, EITHER
LOCAL OR GENERAL, WILL DEPEND ON THE CONDITIONS OF USE,
QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS,
RESPIRATORY: USE APPROVED RESPIRATOR EQUIPMENT. FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIP-
MENT (AIR- PURIFYING, AIR - SUPPLIED, OR SELF- CONTAINED BREATHING
APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR
FACE SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL
AND CONDITIONS OF USE,
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED. THE CHOICE OF
MATERIAL MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER
REQUIREMENTS, GENERALLY, NEOPRENE OFFERS ACCEPTABLE CHEMICAL
RESISTANCE, INDIVIDUALS WHO ARE ACUTELY AND SPECIFICALLY
SENSITIVE TO 1,4- DIOXANE MAY REQUIRE ADDITIONAL PROTECTIVE
EQUIPMENT.
PAGE 3
r
STORAGE:
OTHER:
i.,4- DIOXANE SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND
DIRECT SUNLIGHT. PROPER STORAGE OF 1,4- DIOXANE MUST BE
DETERMINED BASED ON OTHER MATERIALS STORED AND THEIR HAZARDS
AND POTENTIAL CHEMICAL INCOMPATIBILITY. IN GENERAL, 1,4-
DIOXANE SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND
SECURE FLAMMABLE LIQUID STORAGE ROOM. CHECK PERIODICALLY FOR
PEROXIDES IN STORED MATERIAL AND PRIOR TO USE, ESPECIALLY
BEFORE CONCENTRATING OR HEATING,, DO NOT OPEN CONTAINER IF
PEROXIDE CRYSTALS FORM IN I..IQUID OR AROUND CLOSURE. DO NOT
CONCENTRATE IF PEROXIDE CONCENTRATIONS EXCEED 0,01% OR 100 PPM,
CONTACT.THE MANUFACTURER FOR APPROPRIATE PEROXIDE TREATMENT AND
HANDLING METHODS.
EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD BE
AVAILABLE IN THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND
AND BOND METAL CONTAINERS TO MINIMIZE STATIC SPARKS,
VII. SPILL AND DISPOSAL DATA
SPILL CONTROL: PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT. AI'SORO SPILLED MATERIAL IN AN
ABSORBENT RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE
LOCATION FOR DISPOSAL BY APPROVED METHODS. IF RELEASED TO THE
ENVIRONMENT, COMPLY WITH ALL REGULATORY NOTIFICATION REQUIRE-
MENTS. CERCLA REPORTABLE QUANTITY: 100 POUNDS.
WASTE DISPOSAL: DISPOSE OF 1,4- DIOXANE AS AN EPA HAZARDOUS WASTE. CONTACT
STATE ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS
WASTE DISPOSAL FACILITIES AND APPLICABLE REGULATIONS.
HAZARDOUS WASTE NUMBER: U109 (TOXIC); DOO1. (IGNITABLE).
VIII. SARA /TITLE III DATA
HAZARD CLASSIFICATION CHEMICAL LISTINGS
IMMEDIATE HEALTH: YES (IRRITANT) EXTREMELY HAZARDOUS SUBSTANCES: NO
DELAYED HEALTH: YES CERCLA HAZARDOUS SUBSTANCES: YES
FIRE: YES TOXIC CHEMICALS: YES
SUDDEN RELEASE: NO
REACTIVE: NO
1,4- DIOXANE IS SUBJECT TO THE REPORTING REQUIRE..MENTS OF SECTION 313 OF TITLE
III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND
40CFR PART 372. THIS PRODUCT'DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE
1% CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL_ RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "fUNOAMENTAL.S OF INDUSTRIAL HYGIENE," 3R0
ED., 1988)
PAGE 4
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF, BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL, NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABIL.ITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SUCH INFORMATION REFERS. BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, Tt -IIS INFORMATION,
PAGE 5 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
# #######################################] k414#] k# # # # # ## # # # # # # # # # # # # # # # # # # # # # # # ##
f *tttt *4I *tttttt # #t #it ## CA- IDMS /DC 12.0 VERSION 00064 #ik## #i # # # # # # ##### ### #it##
t*tt*4tt t *t *4tttt# ###t## # ## #t¢# # #tt*t ## tuft* ttt *t *ttttt ##tttttt#ttttttttt4 # # ##
t *tt444#t #4 44444 USER ID = 005203 44444 # # ## # # # # ###
tttttt######tt## REPORT ID = PRRF2586 # # ##* #tt tt # # #t#
#ik # *t *tt * ### #### LTERM ID = UCLT0031. #t# # # 14t #0114 # #44
## ## ## #4 # # 444t4# INFO NAME = SOSCSIT5 # #4 #4# # # # #1h# # #4#
ttttttt$tt # ## # ## TIME AND GATE OF CREATION = 13 :37:04 98,190 # 4# #ttttitttt *4$
####t########## t***4t ikt# t#*###tt4tt Itt***# t*# 4t# #t # #t #t #tt #t##tt #11t**t#t #t #t ##
:1tttt ttttttttfttt # #t###ttttttt# 444#tt*tt$####### ## # ## ## ## #iktttt #t# #### ##4#####
################### # # # # # # # # # # # # # ##### # # # # ## # # #444f # #* # # # # # # # ## ## # # ## #4444 # # # ##
BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
ACETONE
REVISION PATE: DECEMBER, 1993
REVISION NO: 1
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800.424,9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996,6666
I. IDENTIFICATION
CHEMICAL NAME:
CHEMICAL FAMILY:
SYNONYMS:
DOT PROPER SHIPPING NAME:
DOT HAZARD CLASS:
DOT IDENTIFICATION NUMBER:
ACETONE MOLECULAR WEIGHT: 58.08
KETONE FORMULA: C3H60
DIMETHYL KETONE
ACETONE
FLAMMABLE LIQIJID, HAZARD CLASS 3, P.G. II
UN1.090 CAS NUMBER: 67 -64 -1
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM HG:
VAPOR PRESSURE AT 20 C:
Z VOLATILES BY VOLUME:
FREEZING POINT:
VAPOR DENSITY:
SPECIFIC GRAVITY (F120 =1):
EVAPORATION RATE:
SOLUBILITY IN WATER:
STABILITY:
HAZARDOUS POLYMERIZATION:
APPEARANCE AND ODOR:
CONDITIONS TO AVOID:
MATERIALS TO AVOID:
HAZARDOUS DECOMPOSITION
PRODUCTS:
56.29 C
184.5 MM HG
CA 100
-94.7
2.0
0 20 C 0.79
(BUAC =1) CA 12
20 C COMPLETE
STABLE
NOT EXPECTED TO OCCUR,
CLEAR, COLORLESS LIQUID WITH A PENETRATING, SWEET
ODOR.
HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
STRONG OXIDIZING AGENTS AND STRONG ACIDS AND BASES.
INCOMPLETE COMBUSTION CAN GENERATE CARBON MONOXIDE
AND OTHER TOXIC VAPORS.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD): -18 C (TAG CLOSED CUP)
AUTO IGNITION TEMPERATURE: 465 C
FLAMMABLE LIMITS IN AIR % BY VOLUME: L.Ot.JER LIMIT 2.6 UPPER LIMIT: 12.8
UNUSUAL FIRE AND EXPLOSION HAZARDS: VERY VOLATILE AND EXTREMELY FLAMMABLE;
MTYTIII?rR I.ITTI -1 I.IAT1=P rem Pr rl AMMefI r
SPECIAL FIRE FIGHTING PROCEDURES:
IV. HAZARDOUS COMPONENTS
...ETONE WT.% CA 100
V. HEALTH HAZARDS
WEAR FULLY PROTECTIVE CLOTHING AND SELF -
CONTAINED BREATHING APPARATUS, HEAT WILL
BUILD PRESSURE AND MAY RUPTURE CLOSED
STORAGE CONTAINERS, KEEP FIRE - EXPOSED
CONTAINERS COOL WITH WATER SPRAY.
TLV 750 PPM CAS NO. 67 -64 -1
OCCUPATIONAL EXPOSURE LIMITS
OSHA TWA 750 PPM
STEL 1,000 PPM
CEILING NOT LISTED
ACGIH TLV -TWA 750 PPM
TLV -STEL 1,000 PPM
NIOSH 10 -HOUR TWA 250 PPM
CONCENTRATION IMMEDIATELY
OANGEROUS TO HEALTH
OSHA /NIOSH 20,000 PPM
ODOR THRESHOLD
NSC 2 PPM
NIOSH NOT LISTED
CARCINOGENIC DATA
ACETONE IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACGIH.
PRIMARY ROUTES OF ENTRY
ACETONE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE /SIGNS AND SYMPTOMS.
INHALATION: EXPOSURE CAN CAUSE EYE, NOSE, AND THROAT IRRITATION, HEADACHE,
NAUSEA, DIZZINESS AND NARCOSIS,
LIQUID ANO HIGH VAPOR CONCENTRATION CAN CAUSE IRRITATION.
PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE IRRITATION AND
DERMATITIS THROUGH OEFATTING OF SKIN,
SYMPTOM INFORMATION IS INADEQUATE /UNKNOWN.
EYE CONTACT:
SKIN CONTACT:
INGESTION:
EFFECTS OF OVEREXPOSURE
ACETONE IS A MILD EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY SKIN IRRITANT, AND
CENTRAL NERVOUS SYSTEM DEPRESSANT. ACUTE EXPOSURE IRRITATES THE EYES AND UPPER
RESPIRATORY TRACT. DIRECT SKIN CONTACT PRODUCES DERMATITIS, CHARACTERIZED BY
DRYNESS AND ERYTHEMA. HIGH CONCENTRATIONS PRODUCE NARCOSIS AND HYPOGLYCEMIA.
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS SUSCEPTIBLE TO DERMATITIS.
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING, IF THERE IS NO PULSE,
ADMINISTER CARDIOPULMONARY RESUSCITATION (CPR), CONTACT
PHYSICIAN IMMEDIATELY.
PAGE 2
EYE CONTACT: RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
GET EMERGENCY MEDICAL ASSISTANCE,
SKIN CONTACT:
FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES.
WASH CLOTHING BEFORE RE-USE, AND DISCARD CONTAMINATED SHOES.
GET EMERGENCY MEDICAL ASSISTANCE,
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT
PHYSICIAN IMMEDIATELY. NEVER INDUCE VOMITING OR GIVE ANYTHING
BY MOUTH TO A VICTIM UNCONSCIOUS OR HAVING CONVULSIONS.
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE
FIRE HAZARDS. THE CHOICE OF VENTILATION EQUIPMENT, EITHER
LOCAL OR GENERAL, WILL DEPEND ON THE CONDITIONS OF USE,
QUANTITY OR MATERIAL, AND OTHER OPERATING PARAMETERS.
RESPIRATORY: USE APPROVED RESPIRATOR EQUIPMENT. FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMlNE APPROPRIATE
EQUIPMENT (AIR-PURIFYING, AIR-SUPPLIED, OR SELF-CONTAINED
BREATHING APPARATUS).
EYES: SAFETY GLASSES ARE GOGGLES OR
FACE SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL
AND CONDITIONS OF USE.
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED. THE CHOICE OF
MATERIAL MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER
REQUIREMENTS, GENERALLY, NEOPRENE OR RUBBER OFFERS ACCEPTABLE
CHEMICAL RESISTANCE. INDIVIDUALS WHO ARE ACUTELY AND
SPECIFICALLY SENSITIVE TO ACETONE MAY REQUIRE ADDITIONAL
PROTECTIVE EQUIPMENT.
STORAGE: ACETONE SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND
DIRECT SUNLIGHT. PROPER STORAGE OF ACETONE MUST BE DETERMINED
BASED ON OTHER MATERIALS STORED AND THEIR HAZARDS AND
POTENTIAL CHEMICAL INCOMPATIBILITY. IN GENERAL, ACETONE
SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND SECURE
FLAMMABLE LIQUID STORAGE ROOM,
OTHER: EMERGENCY EYEWASH NS AND SAFETY SHOWERS ULD BE
AVAILABLE IN THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND
AND BOND METAL CONTAINERS TO MINIMIZE STATIC SPARKS,
VII. SPILL AND DISPOSAL DATA
SPILL CONTROL:
PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT. ABSORB SPILLED MATERIAL IN
AN ABSORBENT RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A
SAFE LOCATION DISPOSAL BY APPROVED METHODS. IF RELEASED
TO THE ENVIRONMENT, COMPLY WITH ALL REGULATORY NOTIFICATION
REQUIREMENTS. CERCLA REPORTABLE QUANTITY: 5,000 POUNDS.
PAGE 3
WASTE DISPOSAL: DISPOSE OF ACETONE AS AN EPA HAZARDOUS WASTE. CONTACT STATE
ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS WASTE
DISPOSAL FACILITIES AND APPLICABLE REGULATIONS. HAZARDOUS
WASTE NUMBER: U003 (IGNITABLE, TOXIC); 0001 (IGNITABLE).
HAZARD CLASSIFICATION CIIEMICAL. LISTINGS
IMMEDIATE HEALTH: YES (IRRITANT) EXTREMELY HAZARDOUS SUBSTANCES: NO
DELAYED HEALTH: NO CERCLA HAZARDOUS SUBSTANCES: YES
FIRE: YES TOXIC CHEMICALS: YES
SUDDEN RELEASE: NO
REACTIVE: NO
ACETONE TS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 312 OF TITLE III OF
THE SUPERFUND AMENDMENTS AND REAIJTHORIZ_ATION ACT OF 1986 (SARA) AND 40CFR PART
372. THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE 1%
CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION.
KEY
CA APPROXIMATELY STET. SHORT TERM EXPOSURE LEVEL (15 MINUTES)
NA NOT APPLICABLE TLV THRESHOLD LIMIT VALUE
C CEILING TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "FUNDAMENTALS OF INDUSTRIAL_ HYGIENE," " 3R0
ED., 1988)
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF, BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WLIICH SUCH INFORMATION REFERS. BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
ACETONITRILE
REVISION DATE: DECEMBER, 1993
REVISION NO. 1
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800.424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME ACETONITRILE MOLECULAR IJEIGHT
CHEMICAL FAMILY NITRILE FORMULA
SYNONYMS METHYL CYANIDE, CYANOMETHANE
DOT PROPER SHIPPING NAME ACETONITRILE
DOT HAZARD CLASS FLAMMABLE LIQUID, HAZARD CLASS 3; P.G. II
DOT IDENTIFICATION NUMBER UN1648 CAS NUMBER
II. PHYSICAL AND CHEMICAL DATA
41.05
C2H3N
75--05 -8
BOILING POINT, 760MM HG 81.6 C
VAPOR PRESSURE AT 20 C 72.8 MM HG
VOLATILES BY VOLUME CA 100
FREEZING POINT -43.8 C
VAPOR DENSITY (AIR =1) 1.4.
SPECIFIC GRAVITY (H20 =1) 0 20 C 0.78
EVAPORATION RATE (BUAC =1) CA 5
SOLUBILITY IN WATER 0 20 C COMPLETE
STABILITY STABLE
HAZARDOUS POLYMERIZATION NOT EXPECTED TO OCCUR
APPEARANCE AND ODOR CLEAR, COLORLESS LIQUID WITH A SWEET, ETHER -LIKE
ODOR
CONDITIONS TO AVOID HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND
POOR VENTILATION
MATERIALS TO AVOID
HAZARDOUS DECOMPOSITION PRODUCTS
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD) 5.6 C (CLOSED CUP) AUTO IGNITION TEMPERATURE 524 C
FLAMMABLE LIMITS IN AIR X BY VOLUME: LOWER LIMIT 3.0 UPPER LIMIT 16,0
UNUSUAL FIRE AND EXPLOSION HAZARDS VERY VOLATILE AND EXTREMELY FLAMMABLE
EXTINGUISHING MEDIA CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL
FOAM, WATER MIST OR FOG
SPECIAL FIRE FIGHTING PROCEDURES WEAR FULL PROTECTIVE CLOTHING AND SELF -
CONTAINED BREATHING APPARATUS. HEAT WILL
BUILD PRESSURE AND RUPTURE CLOSED STORAGE
CONTAINERS. WATER SPRAY MAY BE INEF-
FECTIVE DIRECTLY ON FIRE, BUT SHOULD BE
USED TO COOL FIRE - •EXPOSED CONTAINERS.
PAGE 1
IV. HAZARDOUS COMPONENTS
ACETONITRILE (METHYL CYANIDE) CA 100 TLV 40 PPM (SKIN) CAS NO. 75-05-8
V. HEALTH HAZARDS
OCCUPATIONAL EXPOSURE LIMITS CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
OSHA TWA 40 PPM OSHA/NIOSH 4^000 PPM
STEL 60 PPM
CEILING NOT LISTED
ACGIH
ODOR THRESHOLD
TLV-TWA 40 PPM (SKIN)
TLV-STEL 60 PPM (SKIN) NSC
NIOSH
NIOSH 1O-HOUR TWA 20 PPM
NOT LISTED
40 PPM
CARCINOGENIC DATA
ACETONITRILE IS NOT LISTED AS A CARCINOGENIC BY IARC, NTP, OSHA, OR ACGIH.
ANIMAL TESTS HAVE INDICATED TERATOGENIC EFFECTS. RTEC REPORTS TERATOGENIC
EFFECTS IN ANIMALS,
PRIMARY ROUTES OF ENTRY
ACETONITRILE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE/SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE HEADACHE, WEAKNESS, NAUSEA, REDUCED PULSE
RATE AND BLOOD PRESSURE, PALE OR ASHEN SKIN, SUBNORMAL TEMPER-
ATURE, SHALLOW RESPIRATION, CONVULSION, COLLAPSE, AND DEATH AT
HIGH CONCENTRATIDNS,
EYE CONTACT: LIQUID AND HIGH VAPOR CONCENTRATION CAN CAUSE IRRITATION,
SKIN CONTACT: CAN CAUSE IRRITATION AND THE SAME SYSTEMIC SYMPTOMS AS
INHALATION.
INGESTION: SWALLOWING MORE THAN 2 OUNCES OF ACETONITRILE CAN HAVE AN
ADVERSE EFFECT ON THE CENTRAL NERVOUS SYSTEM,
EFFECTS OF OVEREXPOSURE
ACETONITRILE IS AN IRRITANT AND A CHEMICAL ASPHYXIANT. ACUTE EXPOSURE THROUGH
INHALATION, INGESTION, OR SKIN ABSORPTION CAUSES HEADACHE, VOMITING,
DROWSINESS, CHEST PAIN, UNCONSCIOUSNESS, SHOCK, AND DEATH. SEVERAL HOURS MAY
ELAPSE BETWEEN EXPOSURE AND INITIATION OF SYMPTOMS, DUE TO SLOW RELEASE OF
CYANIDE. CHRONIC EXPOSURES CAN PRODUCE DAMAGE TO THE LIVER AND KIDNEYS.
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS WITH DISEASE OF LIVER, KIDNEYS, SKIN,
AND CENTRAL NERVOUS SYSTEM.
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER
MOUTH-TO-MOUTH RESCUE BREATHING. IF THERE IS NO PULSE,
ADMINISTER CARDIOPULMONARY RESUSCITATION (CPR). CONTACT
PHYSICIAN IMMEDIATELY.
PAGE 2
EYE CONTACT:
SKIN CONTACT:
RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
GET EMERGENCY MEDICAL ASSISTANCE.
FLUSH R AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER, REMOVE CONTAMINATED CLOTHING AND SHOES.
WASH CLOTHING BEFORE RE-USE, AND DISCARD CONTAMINATED SHOES.
GET EMERGENCY MEDICAL ASSISTANCE.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT
PHYSICIAN IMMEDIATELY. NEVER INDUCE VOMITING OR GIVE ANYTHING
BY MOUTH TO A VICTIM UNCONSCIOUS OR HAVING CONVULSIONS.
NOTE TO PHYS
MAXIMUM ACUTE EFFECTS MAY BE DELAYED SEVERAL HOURS. ANY EXPOSED PERSON SHOULD
BE KEPT UNDER SURVEILLANCE. FOR SEVERE EXPOSURE, TREAT AS CYANIDE POISONING.
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION; ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE
FIRE HA7ARDS, THE CHOICE OF VENTILATION EQUIPMENT, EITHER
LOCAL OR GENERAL, WILL DEPEND ON THE CONDITIONS OF USE,
QUANTITY OR MATERIAL, AND OTHER OPERATING PARAMETERS.
RESPIRATORY: USE APPROVED IPM[NT. FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIP-
MENT (AIR-PURIFYING, AIR-SUPPLIED, OR SELF-CONTAINED BREATHING
APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION, GOGGLES OR
FACE SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL
AND CONDITIONS OF USE.
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED. THE CHOICE OF
MATERIAL MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER
REQUIREMENTS. GENERALLY, NEOPRENE OR RUBBER OFFERS ACCEPTABLE
CHEMICAL RESISTANCE. INDIVIDUALS WHO ARE ACUTELY AND SPECI-
FICALLY SENSITIVE TO ACETONITRILE MAY REQUIRE ADDITIONAL
PROTECTIVE EQUIPMENT.
STORAGE: ACETONITRILE SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND
DIRECT SUNLIGHT. PROPER STORAGE OF ACETONITRILE MUST BE
DETERMINED BASED ON OTHER MATERIALS STORED AND THEIR HAZARDS
AND POTENTIAL CHEMICAL INCOMPATIBILITY. IN GENERAL, ACETONI-
TRILE SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND SECURE
FLAMMABLE LIQUID STORAGE ROOM,
OTHER: EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS LD BE
AVAILABLE IN THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND
AND BOND METAL CONTAINERS TO MINIMIZE STATIC SPARKS.
PAGE 3
. VII. SPILL AND DISPOSAL_ DATA
SPILL CONTROL: PROTECT FROM IGNITION, WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT, ABSORB SPILLED MATERIAL IN AN
ABSORBENT RECOMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE
LOCATION FOR DISPOSAL BY APPROVED METHODS, IF RELEASED TO THE
ENVIRONMENT, COMPLY WITH ALL REGULATORY NOTIFICATION REQUIRE -
MENTS. CERCLA REPORTABLE QUANTITY: 5000 POUNDS
WASTE DISPOSAL: DISPOSE OF ACETONTTRIL.E AS AN EPA HAZARDOUS WASTE. CONTACT
STATE ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS
WASTE DISPOSAL FACILITIES AND APPLICABLE REGULATIONS,
HAZARDOUS WASTE NUMBER: U003 (IGNITABLE, TOXIC)) D001
(IGNITABLE).
HAZARD CLASSIFICATION CHEMICAL. LISTINGS
IMMEDIATE HEALTH YES EXTREMELY HAZARDOUS SUBSTANCES NO
DELAYED HEALTH YES CERCLA HAZARDOUS SUBSTANCES YES
FIRE YES TOXIC CHEMICALS YES
SUDDEN RELEASE NO
REACTIVE NO
ACETONITRILE IS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF THE
SUPERFUND AMENDMENTS AND REAUTH-IORIZATION ACT OF 1986 (SARA) AND 40CFR PART 372.
THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE ]% CONCENTRATION
OR A CARCINOGEN ABOVE 0.1% CONCENTRATION,
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABIL.ITY ACT
OF 1980
NSC NATIONAL SAFETY COUNCIL. ( "FUNDAMENTALS OF INDUSTRIAL HYGIENE," 3R0
ED., 1988
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF. BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY, IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS'INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL, NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESSED
OR IMPLIED, OF MERCI- IANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SUCH INFORMATION REFERS, BURDICK
& JACKSON NEITHER ASSUMES NO AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
MATERIAL. SAFETY DATA SHEET
EM SCIENCE
11. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
MANUFACTURER
EM SCIENCE
A DIVISION OF EM INDUSTRIES
P.O. BOX 70
480 DEMOCRAT RD.
GIBBSTOWN, N.J. 08027
CATALOG NUMBER(S):
AX0441 AX0441T AX0445
PRODUCT NAME..,..:
ALCOHOL, REAGENT, ANHYDROUS
SYNQNYMS,,.,.,,,,:
ETHYL ALCOHOL; DENATURED ALCOHOL
CHEMICAL FAMILY,.:
ALIPHATIC ALCOHOL
FORMULA
C2H5OH
MOLECULAR WEIGHT,:
46,07
PREPARATION DATE.: 04/05/95
DATE MSDS PRINTED,: OCT 19, 1995
INFORMATION PHONE NUMBER.: 609 -423 -6300
HOURS: MON, TO FRI. 8:30 -5
CHEMTREC EMERGENCY NUMBER: 800 -424 -9300
HOURS: 24 HRS A DAY
2. COMPOSITION / INFORMATION ON INGREDIENTS
COMPONENT CAS *
ETHYL ALCOHOL
METHANOL
ISO - PROPYL ALCOHOL
13, HAZARDS IDENTIFICATION
64 -17 -5
67 -56 -1
67 -63 -0
APPR
90%
5%
5%
EMERGENCY OVERVIEW
FLAMMABLE LIQUID AND VAPOR.
VAPOR HARMFUL.
MAY BE FATAL OR CAUSE BLINDNESS IF SWALLOWED.
CANNOT BE MADE NON - POISONOUS.
MAY CAUSE DAMAGE TO LIVER, KIDNEYS, GASTROINTESTINAL TRACT AND
CARDIOVASCUL.AR SYSTEM.
MSDS (CONNTINUED) - AX0441 PAGE 0 1
APPEARANCE
COLORLESS LIQUID, CHARACTERISTIC ODOR
•
POTENTIAL HEALTH EFFECTS (ACUTE AND CHRONIC)
SYMPTOMS OF EXPOSURE:
CAN BE FATAL OR CAUSE BLINDNESS IF SWALLOWED IN QUANTITY,
CAUSES HEADACHE, NAUSEA, DIZZINESS, NARCOSIS,
CHRONIC OVEREXPOSURE'(INHAL.ATI'ON OR INGESTION) CAN CAUSE DAMAGE
TO GASTROINTESTINAL TRACT, LIVER, KIDNEYS AND CARDIOVASCULAR SYSTEM.
PROLONGED CONTACT CAUSES IRRITATION TO SKIN AND EYES.
MEDICAL COND. AGGRAVATED BY EXPOSURE:
KIDNEY, LIVER, HEART AND GI CONDITIONS.
ROUTES OF ENTRY..
INHALATION, INGESTION OR SKIN CONTACT,
CARCINOGENICITY...,..,, . ..:
THE MATERIAL IS NOT LISTED (IARC, NTP, OSIIA) AS CANCER CAUSING
AGENT.
4. FIRST AID MEASURES
EMERGENCY FIRST AID:
GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE.
SKIN: AWASH THOROUGHLY IJITH SOAP AND WATER.
EYES: IMMEDIATELY FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15
MINUTES.
INHALATION: REMOVE TO FRESH AIR; GIVE ARTIFICIAL_ RESPIRATION IF
BREATHING HAS STOPPED,
INGESTION: IF CONSCIOUS, DRINK WATER AND INDUCE VOMITING
IMMEDIATELY AS DIRECTED BY MEDICAL PERSONNEL, NEVER GIVE ANYTHING
BY MOUTH TO AN UNCONSCIOUS PERSON.
5. FIRE FIGHTING MEASURES
FLASH POINT (F)..........: 54F (CC)
FLAMMABLE LIMITS LEL (X).: 3;30
FLAMMABLE LIMITS UEL (Y.).: 19.00
EXTINGUISHING MEDIA
ALCOHOL" FOAM, CO2, DRY CHEMICAL
FIRE FIGHTING PROCEDURES.:
WEAR SELF - CONTAINED BREATHING APPARATUS AND PROTECTIVE CLOTHING.
FIRE & EXPLOSION HAZARDS.:
VAPOR CAN TRAVEL DISTANCES TO IGNITION SOURCE AND FLASH BACK.
6. ACCIDENTAL RELEASE MEASURES
MSDS (CONTINUED) - AX0441 PAGE t 2
SPILL RESPONSE:
EVACUATE THE AREA OF ALL UNNECESSARY PERSONNEL.
WEAR SUITABLE PROTECTIVE EQUIPMENT LISTED UNDER EXPOSURE /
PERSONAL PROTECTION.
ELIMINATE ANY IGNITION SOURCES UNTIL THE AREA IS DETERMINED TO BE
FREE FROM EXPLOSION OR FIRE HAZARDS.
CONTAIN THE RELEASE AND ELIMINATE ITS SOURCE, IF THIS CAN B.F. DONE
WITHOUT RISK.
TAKE UP AND CONTAINERIZE FOR PROPER DISPOSAL AS DESCRIBED UNDER
DISPOSAL.
COMPLY WITH FEDERAL,' STATE, AND LOCAL REGULATIONS ON REPORTING
RELEASES, REFER TO REGULATORY INFORMATION FOR REPORTABLE
QUANTITY AND OTI -IER REGULATORY DATA.
EM SCIENCE RECOMMENDS SPILL -X ABSORBENT AGENTS FOR VARIOUS TYPES
OF SPILLS. ADDITIONAL INFORMATION ON THE SPILL -X PRODUCTS CAN BE
PROVIDED THROUGH THE EM SCIENCE TECHNICAL SERVICE DEPARTMENT
(609) 354 -9200.
THE FOLLOWING EM SCIENCE SPILL-•X ABSORBENT IS RECOMMENDED FOR
THIS PRODUCT:
SX0863 SOLVENT SPILL TREATMENT KIT
7. HANDLING AND STORAGE
HANDLING & STORAGE:
KEEP CONTAINER CLOSED.
STORE IN A COOL AREA AWAY FROM IGNITION SOURCES AND OXIDIZERS.
DO NOT BREATHE VAPOR,
DO NOT GET IN EYES,
AVOID PROLONGED, OR REPEATED, SKIN CONTACT.
ELECTRICALLY GROUND ALL EQUIPMENT WHEN HANDLING THIS PRODUCT.
RETAINED RESIDUE MAY MAKE EMPTY CONTAINERS HAZARDOUS; USE
CAUTION!
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS AND PERSONAL PROTECTIVE EQUIPMENT:
VENTILATION, RESPIRATORY PROTECTION, PROTECTIVE CLOTHING, EYE PROTECTION
MATERIAL SHOULD BE HANDLED OR TRANSFERRED IN AN APPROVED FUME
HOOD OR WITH ADEQUATE VENTIL.ATION.
PROTECTIVE GLOVES (NEOPRENE, NITRILE OR EQUIVALENT) SHOULD. BE
WORN TO PREVENT SKIN CONTACT.
SAFETY GLASSES IJITI-I SIDE SHIELDS SHOULD BE WORN AT ALL TIMES.
WORK / HYGENIC PRACTICES:
WASH THOROUGHLY AFTER HANDLING.
DO NOT TAKE INTERNALLY.
EYE WASH AND SAFETY EQUIPMENT SHOULD BE READILY AVAILABLE.
MSDS (CONTINUED) - AX0441 PAGE 4 3
• EXPOSURE GUIDELINES
OSHA — PEL:
COMPONENT PPM TWA Mr, PPM STEL /M3 CL
ETHYL ALCOHOL
1000 1900
METHANOL
200 260 250 325
ISO — PROPYL ALCOHOL
400 980 500 1225
PPM MG /M3 SKIN
ACGIH — TLV:
TWA STEL CL
COMPONENT PPM MG /M3 PPM MG /M3 PPM MG /M3 SKIN
ETHYL ALCOHOL
1000 1880
METHANOL
200 262 250 328
ISO— PROPYL ALCOHOL
400 983 500 1230
•
•
9, PHYSICAL AND CHEMICAL PROPERTIES
BOILING POINT (C 760 MMHG) , 77C
MELTING POINT (C) • c -144C
SPECIFIC GRAVITY (H20 = 1).: 0.79.
VAPOR PRESSURE (MM HG),.. , : 48 20C
PERCENT VOLATILE BY VOL (X): 99 +X
VAPOR DENSITY (AIR = 1) 1.6
EVAPORATION RATE (BOAC = 1): 3,1
SOLUBILITY IN WATER (X) MISCIBLE
APPEARANCE
COLORLESS LIQUID, CHARACTERISTIC ODOR
10, STABILITY AND REACTIVITY'
STABILITY ' YES
HAZARDOUS POLYMERIZATION:
DOES NOT OCCUR
HAZARDOUS DECOMPOSITION,:
COX
MSDS (CONTINUED)_ - AX0441: PAGE 4 4
CONDITIONS TO AVOID....,:
HEAT; CONTACT WITH IGNITION SOURCES.
MATERIALS TO AVOID
( ) WATER
( ) ACIDS
( ) BASES
( ) CORROSIVES
(X) OXIDIZERS
( ) OTHER
11, TOXICOLOGICAL INFORMATION
TOXICITY DATA:
ORL -HMN LDLO: 1400 MG /I <G
TOXICOLOGICAL FINDINGS:
TESTS ON LABORATORY ANIMALS INDICATE MATERIAL MAY CAUSE TUMORS
AND PRODUCE ADVERSE MUTAGENIC AND REPRODUCTIVE EFFECTS.
CITED IN REGISTRY OF TOXIC EFFECTS OF CHEMICAL SUBSTANCES (RTECS)
12, DISPOSAL CONSIDERATIONS
EPA WASTE NUMBERS: D001
TREATMENT:
INCINERATION, FUELS BLENDING OR RECYCLE. CONTACT YOUR LOCAL
PERMITTED WASTE DISPOSAL SITE (TSD) FOR PERMISSIBLE TREATMENT
SITES.
ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE
COMPLIANCE WITH ALL CURRENT LOCAL, STATE AND FEDERAL REGULATIONS.
13. TRANSPORT INFORMATION
DOT PROPER SHIPPING NAME...:
DENATURED ALCOHOL
DOT ID NUMBER
NA1986
14. REGULATORY INFORMATION
TSCA STATEMENT
.
THIS PRODUCT IS A "MIXTURE "; THE CAS NUMBERS OF ALL COMPONENTS
ARE LISTED ON THE TSCA INVENTORY,
MSDS (CONTINUED) - AX0441 PAGE 4 5
COMPONENT
SARA SARA CERCLA
EHS EHS TPQ RQ
(302) (LBS) (LDS)
ETHYL ALCOHOL
METHANOL
ISO-PROPYL ALCOHOL
5000
OSHA SARA DEMINIMIS
COMPONENT FLOOR LIST 313 FOR SARA 313
' . (%)
ETHYL ALCOHOL
Y
METHANOL
` Y Y 1.0
ISO-PROPYL ALCOHOL
0.1
15, OTHER INFORMATION
COMMENTS:
NONE
NEPA HAZARD RATINGS:
HEALTH : 0
FLAMMABILITY : 3
REACTIVITY : 0
SPECIAL HAZARDS �
REVISION HISTORY:
08/01/81 08/01/83 01y17/87 10/27/87 01/20/88 05/26/88 12/15/88
08/28/90 03/01/91
= REVISED SECTION
N/A = NOT AVAILABLE
N/E = NONE ESTABLISHED . '
THE STATEMENTS CONTAINED HEREIN ARE OFFERED FOR INFORMATIONAL PURPOSES
ONLY AND ARE BASED UPON TECHNICAL DATA THAT EM SCIENCE BELIEVES TO BE
ACCURATE. G THE NECESSARY
TECHNICAL SKILL AND AT THEIR UUN OESCRETION AND RISK. SINCE CONDITIONS
AND MANNER OF USE ARE OUTSIDE OUR CONTROL, U[ MAKE NO WARRANTY' EXPRESS
OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE.
PORTIONS COPYRIGHT ARIEL RESEARCH CORPORATION, 1993. RESTRICTED
USE CONDITIONS APPLY. SELECTED REGULATORY INFORMATION IN EMCIS
MSD8 (CONTINUED) - AX0441 PAGE # 6
HAS BEEN DERIVED FROM ARIEL RESEARCH CORP'S, INTERNATIONAL
CHEMICAL REGULATORY MONITORING SYSTEM (ICRMS). USE OF THIS DATA
IS SUBJECT TO THE TERMS OF A LICENSE AGREEMENT BETWEEN EM
INDUSTRIES AND ARIEL RESEARCH CORP, FURTHER DISTRIBUTION
WITHOUT AUTHORIZATION IS PROHIBITED.
MSDS - AX0441 PAGE t 7
"ISSUED BY VWR 07/09/98"
•
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
ETHYL ACETATE
REVISION DATE: JANUARY, 1995
REVISION NO: 1
INFORMATION/EMERGENCY EPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800.424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME: ETHYL ACETATE MOLECULAR WEIGHT/ 88.11
CHEMICAL FAMILY: ESTER FORMULA: C4H802
SYNONYMS: ETHYL ET||ANOATE, ACETIC ACID ETHYL ESTER
DOT PROPER SHIPPING NAME: ETHYL ACETATE
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G. II
DOT IDENTIFICATION NUMBER: UN1173 CAS NUMBER: 141-78-6
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM HG:
VAPOR PRESSURE AT 20 C:
% VOLATILES BY VOLUME:
FREEZING POINT:
VAPOR DENSITY (AIR=1):
SPECIFIC GRAVITY (H2O=1)/
EVAPORATION RATE:
SOLUBILITY IN WATER:
STABILITY:
HAZARDOUS POLYMERIZATION:
APPEARANCE AND ODOR:
CONDITIONS TO AVOID:
MATERIALS TO AVOID:
HAZARDOUS DECOMPOSITION
PRODUCTS:
77.11 C C
73,0 MM HG
CA 100
-83,97 C
3.0
@ 20 C 0.901
(BUAC=1) CA 5
@ 20 C 8.7%
STABLE
NOT EXPECTED TO OCCUR
CLEAR, COLORLESS LIQUID WITH A CHARACTERISTIC FRUITY
ODOR
HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION
STRONG OXIDIZING AGENTS AND STRONG ACIDS AND BASES
INCOMPLETE COMBUSTION CAN GENERATE CARBON MONOXIDE
AND OTHER TOXIC VAPORS
III, FIRE AND EXPLOSION HAZARD DATA
FLASH POINT(TEST METHOD): -4 C(TAG CLOSED CUP) AUTO IGNITION ' PERATURE: 426 C
FLAMMABLE LIMITS IN AIR % BY VOLUME: LOWER LIMIT 2.2 UPPER LIMIT: 11,5
UNUSUAL FIRE AND EXPLOSION HAZARDS: VOLATILE AND FLAMMABLE
EXTINGUISHING MEDIA: CARBON DIOXIDE, DRY CHEMICAL, OR ALCOHOL
FOAM
SPECIAL FIRE FIGHTING PROCEDURES: WEAR FULL PROTECTIVE CLOTHING AND SELF-
CONTAINED BREATHING APPARATUS. HEAT WILL
BUILD PRESSURE AND RUPTURE CLOSED STORAGE
CONTAINERS. KEEP FIRE-EXPOSED CONTAINERS
COOL WITH WATER SPRAY.
PAGE 1
IV, HAZARDOUS COMPONENTS
ETHYL ACETATE
V, HEALTH HAZARDS
WT,% CA 100
TLV 400 PPM CAS NO, 141-78-6
OCCUPATIONAL EXPOSURE LIMITS CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
OSHA TWA 400 PPM
STEL NOT LISTED OSHA /NIOSH 10,000 PPM
CEILING NOT'LISTED
ACGIH TLV -TWA 400 PPM
TLV -STEL NOT LISTED
ODOR THRESHOLD
NIOSH 50 PPM
CARCINOGENIC DATA
ETHYL ACETATE IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACGIH,
PRIMARY ROUTES OF ENTRY
ETHYL ACETATE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ADSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE RESPIRATORY IRRITATION, HEADACHE, NAUSEA,
LIVER AND KIDNEY DAMAGE, AND PULMONARY EDEMA,
LIQUID AND HIGH VAPOR CONCENTRATION CAN CAUSE IRRITATION,
CONJUNCTIVITIS, AND CORNEAL CLOUDING.
EYE CONTACT:
SKIN CONTACT:
INGESTION:
PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE IRRITATION AND
DERMATITIS THROUGH DEFATTING OF SKIN,
CAN CAUSE IRRITATION OF GASTROINTESTINAL TRACT.
EFFECTS OF OVEREXPOSURE
ETHYL ACETATE I5 A MILD EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY SKIN
IRRITANT, AND CENTRAL NERVOUS SYSTEM DEPRESSANT. REPEATED CONTACT WITH ETHYL
ACETATE PRODUCES ECZEMATTOUS AND SENSITIZATION DERMATITIS, ACUTE INHALATION
MAY PRODUCE NARCOSIS, ANEMIA, LIVER AND KIDNEY DAMAGE, AND PULMONARY EDEMA.
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS WITH DISEASES OF EYES, LIVER,
KIDNEYS, LUNGS, AND THOSE SUSCEPTIBLE TO DERMATITIS,
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING,, T.F THERE IS NO PULSE,
ADMINISTER CARDIOPULMONARY RESUSCITATION (CPR). CONTACT
PHYSICIAN IMMEDIATELY,
EYE CONTACT: RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
GET EMERGENCY MEDICAL ASSISTANCE.
PAGE
SKIN CONTACT:
FLUSH THOROUGHLY FOR Al LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES.
WASH CLOTHING BEFORE RE -USE, AND DISCARD CONTAMINATED SHOES.
GET EMERGENCY MEDICAL ASSISTANCE_.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT
PHYSICIAN IMMEDIATELY. NEVER INDUCE VOMITING OR GIVE ANYTHING
BY MOUTH TO A VICTIM UNCONSCIOUS OR HAVING CONVULSIONS.
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL. VAPORS EXCEEDING THE PEL AND TO MINIMIZE
FIRE HAZARDS. THE CHOICE OF VENTILATION EQUIPMENT, EITHER
LOCAL OR GENERAL, WILL DEPEND ON THE CONDITIONS OF USE,
QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS,
RESPIRATORY: USE APPROVED RESPIRATOR EQUIPMENT. FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE
EQUIPMENT (AIR - PURIFYING, AIR - SUPPLIED, OR SELF - CONTAINED
BREATHING, APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR
FACE SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL
AND CONDITIONS OF USE,
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED, THE CHOICE OF
MATERIAL MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER
REQUIREMENTS. GENERALLY, NEOPRENE OR NATURAL RUBBER OFFERS
ACCEPTABLE CHEMICAL RESISTANCE. INDIVIDUALS WHO ARE ACUTELY
AND SPECIFICALLY SENSITIVE TO ETHYL ACETATE MAY REQUIRE
ADDITIONAL PROTECTIVE EQUIPMENT,
STORAGE:
OTHER:
ETHYL ACETATE SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND
DIRECT SUNLIGHT. PROPER STORAGE OF ETHYL ACETATE MUST BE
DETERMINED BASED ON OTHER MATERIALS STORED AND TI -IEIR HAZARDS
AND POTENTIAL CHEMICAL INCOMPATIBILITY. IN GENERAL, ETHYL
ACETATE SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND
SECURE FLAMMABLE LIQUID STORAGE ROOM,
EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD BE
AVAILABLE IN THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND
AND BOND METAL CONTAINERS TO MINIMIZE STATIC SPARKS.
VII. SPILL AND DISPOSAL DATA
SPILL CONTROL: PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT. ADSORB SPILLED MATERIAL_ IN AN
ABSORBENT RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE
LOCATION FOR DISPOSAL BY APPROVED METHODS, IF RELEASED TO THE
ENVIRONMENT, COMPLY WITH ALL REGULATORY NOTIFICATION REQUIRE-
MENTS, CERCLA REPORTABLE QUANTITY: 5,000 POUNDS.
PAGE 3
WASTE DISPOSAL: DISPOSE OF ETHYL ACETATE AS AN EPA HAZARDOUS WASTE. CONTACT
STATE ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS
WASTE DISPOSAL FACILITIES AND APPLICABLE REGULATIONS,
HAZARDOUS WASTE NUMBER: U112 (IGNITABLE); 0001 (IGNITABLE);
F003 (IGNITABLE).
VIII. SARA /TITLE III DATA
HAZARD CLASSIFICATION CHEMICAL LISTINGS
IMMEDIATE HEALTH: YES (IRRITANT) EXTREMELY HAZARDOUS SUBSTANCES: NO
DELAYED HEALTH: 'NO CERCLA HAZARDOUS SUBSTANCES: YES
FIRE: YES TOXIC CHEMICALS: YES
SUDDEN RELEASE: NO
REACTIVE: NO
ETHYL ACETATE IS SUBJECT TO THE REPORTING REGIUIREMENTS OF SECTION 313 OF TITLE
III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND
40CFR PART 372, THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE
1% CONCENTRATION OR A CARCINOGEN ABOVE 0,1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "FUNDAMENTALS OF INDUSTRIAL. HYGIENE," 3R0
ED., 1988)
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF. BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, TIME PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL, NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A (ARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SUCH INFORMATION REFERS, BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION,
PAGE 4 (LAST PAGE)
"ISSUED BY VIM 07/09/98"
BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
ETHYL ETHER
REVISION DATE: DECEMBER, 1993
REVISION NO: 1
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800.424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME: ETHYL ETHER
CHEMICAL FAMILY: ETHER
SYNONYMS: DIETHYL ETHER, ETHER, ETHOXYETHANE
DOT PROPER SHIPPING NAME: ETHYL ETHER
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G. I
DOT IDENTIFICATION NUMBER: UN1155
MOLECULAR WEIGHT: 74,12
FORMULA: C4H100
CAS NUMBER: 60 -29 -7
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM HG: 34.55 C
VAPOR PRESSURE AT 20 C: 442 MM HG
X VOLATILES BY VOLUME: CA 100
FREEZING POINT: -117.4 C
VAPOR DENSITY (AIR =1): 2.6
SPECIFIC GRAVITY (H20 =1): 20 C 0.713
EVAPORATION RATE: (BIJAC =1) > 10
SOLUBILITY IN WATER: 8 20 C 6.89%
STABILITY: UNSTABLE
HAZARDOUS POLYMERIZATION: NOT EXPECTED TO OCCUR.
APPEARANCE AND ODOR: CLEAR, COLORLESS LIQUID WITH A SWEET, PUNGENT ODOR,
CONDITIONS TO AVOID: HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION
MATERIALS TO AVOID: OXIDIZING AGENTS AND STRONG ACIDS
HAZARDOUS DECOMPOSITION PRODUCTS: INCOMPLETE COMBUSTION CAN GENERATE CARBON
MONOXIDE AND OTHER TOXIC VAPORS, EXPLOSIVE PEROXIDES CAN FORM AFTER STANDING
OR UPON EXPOSURE TO AIR OR DIRECT SUNLIGHT.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD): -45 C (TAG CLOSED CUP)
AUTO IGNITION TEMPERATURE: 160 C
FLAMMABLE LIMITS IN AIR X BY VOLUME: LOWER LIMIT: 1.8 UPPER LIMIT 48.0
UNUSUAL FIRE AND EXPLOSION HAZARDS: EXTREMELY VOLATILE AND EXTREMELY
FLAMMABLE. CAN FORM HEAT- SENSITIVE PEROXIDES WHICH MAY EXPLODE ON
CONCENTRATING OR EVAPORATING, STORAGE UNDER HOT CONDITIONS ( >34.6 C) WILL
CAUSE BOILING. COOL. CONTENTS TO ROOM TEMPERATURE (22 C) BEFORE OPENING
CONTAINERS.
PAGE 1
EXTINGUISHING MEDIA: CARBON DIOXIDE, DRY CHEMICAL OR FOAM,
SPECIAL FIRE FIGHTING PROCEDURES: WEAR FULL PROTECTIVE CLOTHING AND SELF -
CONTAINED BREATHING APPARATUS. HEAT WILL BUILD PRESSURE AND MAY RUPTURE CLOSED
STORAGE CONTAINERS, KEEP FIRE - EXPOSED CONTAINERS COOL WITH WATER SPRAY, TREAT
AS FLAMMABLE GAS, SURROUNDINGS MUST BE KEPT COOLED BELOW 160 C TO EXTINGUISH
AN ETHER FIRE AND PREVENT REIGNITION,
IV, HAZARDOUS COMPONENTS
ETHYL ETHER WT.X. CA 100
V. HEALTH HAZARDS
TLV 400 PPM CAS NO. 60 -29 -7
OCCUPATIONAL EXPOSURE LIMITS CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
OSHA TWA 400 PPM
STEL 500 PPM OSHA /NIOSH 19,000 PPM
CEILING NOT LISTED
ODOR THRESHOLD
ACGIH TLV -TWA 400 PPM
TLV -STEL 500 PPM NSC 1.0 PPM
NIOSH 0.33 PPM
CARCINOGENIC DATA
ETHYL ETHER IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACGIH,
PRIMARY ROUTES OF ENTRY
ETHYL ETHER MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTE or EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE HEADACHE, NAUSEA, VOMITING, LOSS OF
CONSCIOUSNESS, AND, IN VERY HIGH CONCENTRATIONS, DEATH DUE TO RESPIRATORY
PARALYSIS.
EYE CONTACT: LIQUID AND HIGH VAPOR CONCENTRATION CAN CAUSE IRRITATION.
SKIN CONTACT: PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE IRRITATION AND
DERMATITIS THROUGH DEFATTING OF SKIN.
INGESTION: SYMPTOM INFORMATION IS INADEQUATE /UNKNOWN,
EFFECTS OF OVEREXPOSURE
ETHYL ETHER IS A MILD EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY SI(IN IRRITANT,
AND CENTRAL NERVOUS SYSTEM DEPRESSANT, ACUTE EXPOSURE CAN CAUSE ANESTHETIC
EFFECTS SUCH AS VOMITING, EXCITEMENT, UNCONSCIOUSNESS, COMA, RESPIRATORY
PARALYSIS, AND DEATH, CHRONIC EXPOSURES MAY PRODUCE CENTRAL NERVOUS SYSTEM
DISTURBANCES.
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS SUSCEPTIBLE TO DERMATITIS,
EMERGENCY FIRST AID
INHALATION: IMMEDIATEL.Y REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING, IF THERE IS NO PULSE, ADMINISTER
CARDIOPULMONARY RESUSCITATION (CPR). CONTACT PHYSICIAN IMMEDIATELY.
PAGE 2
EYE CONTACT: RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
EMERGENCY MEDICAL ASGISTANCE,
SKIN CONTACT: FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES, WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES. WASH CLOTHING
BEFORE RE-USE, AND DISCARD CONTAMINATED SHOES. GET EMERGENCY MEDICAL
ASSISTANCE.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT PHYSICIAN
IMMEDIATELY. NEVER INDUCE VOMITING OR GIVE ANYTHING BY MOUTH TO A VICTIM
UNCONSCIOUS OR HAVING CONVULSIONS.
VI, SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE ETRE HAZARDS.
THE CHOICE OF VENTILATION EQUIPMENT, EITHER LOCAL OR GENERAL, WILL DEPEND ON
THE CONDITIONS OF USE, QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS.
USE APPROVED RESPIRATOR D EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIPMENT (AIR-
PURIFYING, AIR-SUPPLIED, OR SELF-CONTAINED BREATHING APPARATUS).
EYES: SAFETY A ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR FACE
SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL AND CONDITIONS OF
USE.
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED, THE CHOICE OF MATERIAL
MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER REQUIREMENTS. GENERALLY
NEOPRENE OR NITRILE RUBBER OFFERS ACCEPTABLE CHEMICAL RESISTANCE. INDIVIDUALS
WHO ARE ACUTELY AND SPECIFICALLY SENSITIVE TO ETHYL ETHER MAY REQUIRE
ADDITIONAL PROTECTIVE EQUIPMENT.
STORAGE: ETHYL ETHER SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND DIRECT
SUNLIGHT. PROPER STORAGE OF ETHYL ETHER MUST BE DETERMINED BASED ON OTHER
MATERIALS STORED AND THEIR HAZARDS AND POTENTIAL CHEMICAL INCOMPATIBILITY. IN
GENERAL, ETHYL ETHER SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND SECURE
FLAMMABLE LIQUID STORAGE ROOM, DO NOT OPEN CONTAINER IF PEROXIDE CRYSTALS FORM
IN LIQUID OR AROUND CLOSURE. DO NOT CONCENTRATE IF PEROXIDE CONCENTRATIONS
EXCEED 0.01% OR 100 PPM. CONTACT THE MANUFACTURER FOR APPROPRIATE PEROXIDE
TREATMENT AND HANDLING METHODS. STORAGE OF ETHYL ETHER UNDER HOT CONDITIONS 0
34 C) WILL CAUSE THE LIQUID TO BOIL, IF THE CONTAINER IS OPENED BEFORE
ALLOWING TO COOL TO ROOM TEMPERATURE (22 C), THE LIQUID COULD BOIL OVER OUT OF
THE CONT#INER,
OTHER: EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD DE AVAILABLE IN
THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND AND BOND METAL CONTAINERS TO
MINIMIZE STATIC SPARKS,
VII. SPILL AND DISPOSAL DATA
SPILL N PROTECT FROM IGNITION, WEAR PROTECTIVE CLOTHING
APPROVED RESPIRATOR EQUIPMENT. ABSORB SPILLED MATERIAL IN AN ABSORBENT
RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE LOCATION FOR DISPOSAL BY
APPROVED METHODS. IF RELEASED TO THE ENVIRONMENT, COMPLY WITH ALL REGULATORY
NOTIFICATION REQUIREMENTS. CERCLA REPORTABLE QUANTITY: 100 POUNDS.
PAGE 3
J
WASTE DISPOSAL: DISPOSE OF ETHYL ETHER AS AN EPA HAZARDOUS WASTE. CONTACT
STATE ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS WASTE DISPOSAL
FACILITIES AND APPLICABLE REGULATIONS. HAZARDOUS WASTE NUMBER: U117
(IGNITABLE); F003 (IGNITABLE).
HAZARD CLASSIFICATION
IMMEDIATE HEALTH: YES (IRRITANT)
DELAYED HEALTH: NO
FIRE: YES
SUDDEN RELEASE: NO
REACTIVE: NO
CHEMICAL_ LISTINGS
EXTREMELY HAZARDOUS SUBSTANCES: NO
CERCLA HAZARDOUS SUBSTANCES: YES
TOXIC CHEMICALS: NO
ETHYL ETHER IS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE
III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND
40CFR PART 372. THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE
1% CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION,
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL. (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL. RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "FUNDAMENTALS OF INDUSTRIAL. HYGIENE," 3R0
ED., 1988
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF. BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR LJARRANTIES, EITI -IER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SUCH INFORMATION REFERS. BURDICK
& JACKSON NEITFIER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VUR 07/09/98"
• BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
HEXANE
REVISION DATE: DECEMBER, 1993
REVISION NO: 1 .
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800,424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME: HEXANE
CHEMICAL FAMILY: ALIPHATIC HYDROCARBON
SYNONYMS: N- HEXANE
DOT PROPER SHIPPING NAME: HEXANE
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G, II.
DOT IDENTIFICATION NUMBER: UN1208
MOLECULAR WEIGHT: 86.18
FORMULA: C6H14
CAS NUMBER: 110 -54 -3
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM HG: 68.7 C
VAPOR PRESSURE AT 20 C: 124 MM HG
VOLATILES BY VOLUME: CA 100
FREEZING POINT: -95.3 C
VAPOR DENSITY (AIR =1): 3.0
SPECIFIC GRAVITY (H20 =1): e 20 C 0.659
EVAPORATION RATE: (BUAC =1) CA 16
SOLUBILITY IN WATER: @ 20 C 0.014%
STABILITY: STABLE
HAZARDOUS POLYMERIZATION: NOT EXPECTED TO OCCUR.
APPEARANCE AND ODOR: CLEAR, COLORLESS LIQUID WITH A MILD HYDROCARBON ODOR.
CONDITIONS TO AVOID: HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
MATERIALS TO AVOID: STRONG OXIDIZING AGENTS.
HAZARDOUS DECOMPOSITION PRODUCTS: INCOMPLETE COMBUSTION CAN GENERATE CARBON
MONOXIDE AND OTHER TOXIC VAPORS.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD): -26 C (TAG CLOSED CUP)
AUTO IGNITION TEMPERATURE: 225 C
FLAMMABLE LIMITS IN AIR X BY VOLUME: LOWER LIMIT: 1.1 UPPER LIMIT: 7.5
UNUSUAL FIRE AND EXPLOSION HAZARDS: VERY VOLATILE AND EXTREMELY FLAMMABLE.
EXTINGUISHING MEDIA: CARBON DIOXIDE, DRY CHEMICAL. OR FOAM.
PAGE 1
SPECIAL FIRE FIGHTING PROCEDURES: WATER WELL NOT BE EFFECTIVE IN EXTINGUISHING
A FIRE AND MAY SPREAD IT, BUT A WATER SPRAY CAN BE USED TO COOL EXPOSED
CONTAINERS. WEAR FULL PROTECTIVE CLOTHING AND SELF - CONTAINED BREATHING
APPARATUS. HEAT WILL BUILD PRESSURE AND MAY RUPTURE CLOSED STORAGE CONTAINERS.
IV, HAZARDOUS COMPONENTS
HEXANE & ISOMERS
V. HEALTH HAZARDS
WT.% CA 100
TLV 50 PPM CAS NO. 110-54-3
OCCUPATIONAL EXPOSURE LIMITS CONCENTRATION IMMEDIATELY DANGEROUS TO
HEALTH
OSHA TWA 50 PPM OSHA /NIOSH 5,000 PPM
STEL NOT LISTED
CEILING NOT LISTED
ACGIH TLV -TWA 50 PPM
TLV -STEL NOT LISTED NSC NOT LISTED
NIOSH NOT LISTED
NIOSH 10 -HOUR TWA 50 PPM
CEILING NOT LISTED
ODOR THRESHOLD
CARCINOGENIC DATA
HEXANE IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACGIH,
PRIMARY ROUTES OF ENTRY
HEXANE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTES OF EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE DIZZINESS, NUMBNESS OF EXTREMITIES, AND
INTOXICATION,
EYE CONTACT: LIQUID AND HIGH VAPOR CONCENTRATION CAN CAUSE IRRITATION,
SKIN CONTACT: PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE IRRITATION AND
DERMATITIS THROUGH OEFATTING OF SKIN.
INGESTION: CAN CAUSE GASTROINTESTINAL TRACT DISCOMFORT,
EFFECTS OF OVEREXPOSURE
HEXANE IS A MILD EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY SKIN IRRITANT, AND
CENTRAL NERVOUS SYSTEM DEPRESSANT AND NEUROTOXIN, ACUTE EXPOSURE CAUSES
IRRITATION, NARCOSIS, AND GASTROINTESTINAL_ TRACT IRRITATION, CHRONIC INHALATION
CAUSES PERIPHERAL NEUROPATHY, NO SYSTEMIC TOXICITY HAS BEEN REPORTED,
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS SUSCEPTIBLE TO DERMATITIS,
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING,, IF THERE IS NO PULSE, ADMINISTER
CARDIOPULMONARY RESUSCITATION (CPR). CONTACT PHYSICIAN IMMEDIATELY.
EYE CONTACT: RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
EMERGENCY MEDICAL ASSISTANCE.
PAGE 2
~SKIN CONTACT: FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES. WASH CLOTHING
BEFORE RE-USE, AND DISCARD CONTAMINATED SHOES, GET EMERGENCY MEDICAL
ASSISTANCE.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT PHYSICIAN
IMMEDIATELY. ASPIRATION HAZARD - DO NOT INDUCE VOMITING.
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE FIRE HAZARDS.
THE CHOICE OF VENTILATION EQUIPMENT, EITHER LOCAL OR GENERAL, WILL DEPEND ON
THE CONDITIONS OF USE, QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS.
RESPIRATORY: USE APPROVED RESPIRATOR EQUIPMENT, FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIPMENT (AIR-
PURIFYING, AIR-SUPPLIED, OR SELF-CONTAINED BREATHING APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR FACE
SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL AND CONDITIONS OF
USE.
SKIN: PROTECTIVE L
MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER REQUIREMENTS.
NEOPRENE OR NITRILE RUBBER OFFERS ACCEPTABLE CHEMICAL RESISTANCE, INDIVIDUALS
WHO ARE ACUTELY AND SPECIFICALLY SENSITIVE TO HEXANE MAY REQUIRE ADDITIONAL
PROTECTIVE EQUIPMENT.
STORAGE: HEXANE SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND DIRECT
SUNLIGHT. PROPER T E OF HEXANE MUST BE DETERMINED AS OTHER MATERIALS
STORED AND THEIR HAZARDS AND POTENTIAL CHEMICAL INCOMPATIBILITY. IN GENERAL,
HEXANE SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND SECURE FLAMMABLE LIQUID
STORAGE ROOM.
OTHER: EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD BE AVAILABLE IN
THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND AND BOND METAL CONTAINERS TO
MINIMIZE STATIC SPARKS,
VII. SPILL AND DISPOSAL DATA
SPILL FROM IGNITION. WEAR PROTECTIVE CLOTHING
APPROVED RESPIRATOR EQUIPMENT: ABSORB SPILLED MATERIAL IN AN ABSORBENT
RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE LOCATION FOR DISPOSAL BY
APPROVED METHODS. IF RELEASED TO THE ENVIRONMENT, COMPLY WITH ALL REGULATORY
NOTIFICATION CERCLA REPORTABLE QUANTITY: NONE.
WASTE DISPOSAL: DISPOSE OF HEXANE AS AN EPA HAZARDOUS WASTE, CONTACT STATE
ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS WASTE DISPOSAL
FACILITIES AND APPLICABLE REGULATIONS. HAZARDOUS WASTE NUMBER: 0001
(IGNITABLE),
HAZARD CLASSIFICATION
IMMEDIATE HEALTH: YES (IRRITANT)
DELAYED HEALTH: YES
FIRE: YES
SUDDEN RELEASE: NO
REACTIVE: NO
CHEMICAL LISTINGS
EXTREMELY HAZARDOUS SUBSTANCES: NO
CERCLA HAZARDOUS SUBSTANCES: NO
TOXIC CHEMICALS: NO
PAGE 3
'HEXANE IS NOT SUBJECT TO TFIE REPORTING REQUIREMENTS or SECTION 313 OF TITLE III
OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND 40CFR
PART 372. THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE 1%
CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "FUNDAMENTALS OF INDUSTRIAL HYGIENE," 3R0
ED., 1988)
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
HE DATE HEREOF, BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY, IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SLICII INFORMATION REFERS. BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
'BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
. MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
ISOPROPYL ALCOHOL
REVISION DATE: JIJNE, 1995
REVISION NO 2
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800,424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME: ISOPROPYL_ ALCOHOL
CHEMICAL. FAMILY: ALCOHOL
SYNONYMS: 2- PROPANOL, ISOPROPANOL, LACTOL
DOT PROPER SHIPPING NAME: ISOPROPANOL
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G. II
DOT IDENTIFICATION NUMBER: UN1219
MOLECULAR WEIGHT: 60.09
FORMULA: C3H80
CAS NUMBER: 67 -63 -0
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM HG: 82.26 C
VAPOR PRESSURE AT 20 C: 32.4 MM HG
X VOLATILES BY VOLUME: CA 100
FREEZING POINT: -88.0 C
VAPOR DENSITY (AIR =1): 2.1
SPECIFIC GRAVITY (H20 =1): @ 20 C 0,785
EVAPORATION RATE: (BUAC =1) CA 3
SOLUBILITY IN WATER: 0 20 C COMPLETE
STABILITY: STABLE
HAZARDOUS POLYMERIZATION: NOT EXPECTED TO OCCUR.
APPEARANCE AND ODOR: CLEAR, COLORLESS LIQUID WITH A SLIGHT ALCOHIOLIC ODOR.
CONDITIONS TO AVOID: HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
MATERIALS TO AVOID: STRONG OXIDIZING AGENTS, STRONG ACIDS, AND REACTIVE
METALS, INCLUDING ALUMINUM, WHICH WILL DISPLACE HYDROGEN.
HAZARDOUS DECOMPOSITION PRODUCTS: INCOMPLETE COMBUSTION CAN GENERATE CARBON
MONOXIDE AND OTHER TOXIC VAPORS.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD): 12 C (TAO, CLOSED CUP)
AUTO IGNITION TEMPERATURE: 399 C
FLAMMABLE LIMITS IN AIR X BY VOLUME: LOWER LIMIT: 2.0 UPPER LIMIT: 12.0
UNUSUAL FIRE AND EXPLOSION HAZARDS: VOLATILE AND FLAMMABLE.
EXTINGUISHING MEDIA: CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL FOAM, WATER MIST OR
FOG.
PAGE 1
SPECIAL FIRE FIGHTING PROCEDURES: WEAR FULL PROTECTIVE CLOTHING ANO SELF -
CONTAINED BREATHING APPARATUS, HEAT WILL BUILD PRESSURE AND RUPTURE CLOSED
STORAGE CONTAINERS, KEEP FIRE - EXPOSED CONTAINERS COOL WITH WATER SPRAY.
IV. HAZARDOUS COMPONENTS
ISOPROPYL ALCOHOL
V. HEALTH HAZARDS
WT.% CA 100
OCCUPATIONAL EXPOSIJRE'LIMITS
OSHA TWA
STEL
CEILING
ACGIH TLV -TWA
TLV -STEL
NIOSH 10 -HOUR TWA
STEL
TLV 400 PPM CAS NO. 67 -63 -0
CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
400 PPM
500 PPM OSHA /NIOSH 12,000 PPM
NOT LISTED
ODOR THRESHOLD
400 PPM
500 PPM NSC 50 PPM
400 PPM
500 PPM
CARCINOGENIC DATA
ISOPROPYL ALCOHOL IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACGIH,
PRIMARY ROUTES OF ENTRY
ISOPROPYL ALCOHOL MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION,
AND INGESTION.
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE COUGHING, SHORTNESS OF BREATH, DIZZINESS, ANO
INTOXICATION.
EYE CONTACT: LIQUID AND HIGH VAPOR CONCENTRATION CAN CAUSE MODERATE BURNING,
WATERING, SWELLING, AND REDNESS.
SKIN CONTACT: EXTENSIVE, REPEATED AND /OR PROLONGED SKIN CONTACT CAN CAUSE
BURNING, ITCHING, REDNESS, AND DERMATITIS.
INGESTION: CAUSES BURNING OF THE GASTROINTESTINAL TRACT AND TOXIC EFFECTS,
SWALLOWING MORE THAN 250 ML OF ISOPROPYL ALCOHOL CAN CAUSE DEATH,
EFFECTS OF OVEREXPOSURE
ISOPROPYL ALCOHOL IS A MILD EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY SKIN
IRRITANT, AND CENTRAL NERVOUS SYSTEM DEPRESSANT, ACUTE EXPOSURE CAN CAUSE
GASTROINTESTINAL TRACT UPSET AND NARCOSIS.
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS SUSCEPTIBLE TO DERMATITIS.
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR, IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING, IF THERE IS NO PULSE, ADMINISTER.
CARDIOPULMONARY RESUSCITATION (CPR). CONTACT PHYSICIAN IMMEDIATELY,
EYE CONTACT: RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
EMERGENCY MEDICAL ASSISTANCE,
PAGE
SKIN CONTACT: FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES. WASH CLOTHING
BEFORE RE —USE, AND DISCARD CONTAMINATED SHOES. GET EMERGENCY MEDICAL
ASSISTANCE.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT PHYSICIAN
IMMEDIATELY. NEVER INDUCE VOMITING OR GIVE ANYTHING BY MOUTH TO A VICTIM
UNCONSCIOUS OR HAVING CONVULSIONS.
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION I5 REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE FIRE HAZARDS.
THE CHOICE OF VENTIL.ATION EQUIPMENT, EITHER LOCAL OR GENERAL, WILL DEPEND ON
THE CONDITIONS OF USE, QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS,
RESPIRATORY: USE APPROVED RESPIRATOR EQUIPMENT, FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIPMENT (AIR —
PURIFYING, AIR — SUPPLIED, OR SELF— CONTAINED BREATHING APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR FACE
SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL AND CONDITIONS OF
USE,
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED. THE CHOICE OF MATERIAL
MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER REQUIREMENTS, GENERALLY,
NEOPRENE, NITRILE RUBBER, OR NATURAL RUBBER OFFERS ACCEPTABLE CHEMICAL
RESISTANCE. INDIVIDUALS WHO ARE ACUTELY AND SPECIFICALLY SENSITIVE TO
ISOPROPYL ALCOHOL MAY REQUIRE ADDITIONAL PROTECTIVE EQUIPMENT.
STORAGE: ISOPROPYL ALCOHOL SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND
DIRECT SUNLIGHT. PROPER STORAGE OF ISOPROPYL. ALCOHOL MUST DE DETERMINED BASED
ON OTHER MATERIALS STORED AND THEIR HAZARDS AND POTENTIAL CHEMICAL
INCOMPATIBILITY. IN GENERAL, ISOPROPYL. ALCOHOL SHOULD BE STORED IN AN
ACCEPTABLY PROTECTED AND SECURE FLAMMABLE LIQUID STORAGE ROOM.
OTHER: EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD DE AVAILABLE IN
THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND AND BOND METAL CONTAINERS TO
MINIMIZE STATIC SPARKS.
VII. SPILL AND DISPOSAL DATA "a
SPILL CONTROL: PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT. ABSORB SPILLED MATERIAL IN AN ABSORBENT
RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE LOCATION FOR DISPOSAL BY
APPROVED METHODS. IF RELEASED TO THE ENVIRONMENT, COMPLY WITH ALL REGULATORY
NOTIFICATION REQUIREMENTS. CERCLA REPORTABLE QUANTITY: NONE.
WASTE DISPOSAL: DISPOSE OF ISOPROPYL ALCOHOL AS AN EPA HAZARDOUS WASTE.
CONTACT STATE ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS WASTE
DISPOSAL FACILITIES AND APPLICABLE REGULATIONS. HAZARDOUS WASTE NUMBER: D001
(IGNITABLE).
PAGE 3
'HAZARD CLASSIFICATION
IMMEDIATE HEALTH: YES (IRRITANT)
DELAYED HEALTH: NO
FIRE: YES
SUDDEN RELEASE: NO
REACTIVE: NO
CHEMICAL LISTINGS
EXTREMELY HAZARDOUS SUBSTANCES: NO
CERCLA HAZARDOUS SUBSTANCES: NO
TOXIC CHEMICALS: NO
ISOPROPYL ALCOHOL IS NOT SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313.
OF TITLE III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA)
AND 40CFR PART 372, THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL
ABOVE 1% CONCENTRATION OR A CARCINOGEN ABOVE 0,1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL_ RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL. SAFETY COUNCIL. ( "FUNDAMENTALS OF INDUSTRIAL HYGIENE," 3RD
ED„ 1988)
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF. BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY, IT IS THE USER'S RESPONSIBILITY TO DETERMINE_ THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICI -I SUCH INFORMATION REFERS. BURDICK
& JACKSON NEITHER ASSUMES NOR AUTIIORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
,BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
METHANOL
REVISION DATE: DECEMBER, 1993
REVISION NO: 1
INFORMATION /EMERGENCY TELEPHONE NUMBER
CHEMTREC TELEPHONE NUMBER
CANADIAN EMERGENCY TELEPHONE NUMBER
I. IDENTIFICATION
616.726.3171
800.424.9300
613.996.6666
CHEMICAL NAME: METHANOL
CHEMICAL FAMILY: ALCOHOL
SYNONYMS: CARBINOL, METHYL ALCOHOL, WOOD ALCOHOL
DOT PROPER SHIPPING NAME: METHANOL
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G. II
DOT IDENTIFICATION NUMBER: UN1230
MOLECULAR WEIGHT: 32.04
FORMULA: CH40
CAS NUMBER: 67 -56 -1
II. PHYSICAL AND CHEMICAL. DATA
BOILING POINT, 760 MM HG: 64.7 C
VAPOR PRESSURE AT 20 C: 97 MM HG
VOLATILES BY VOLUME: CA 100
FREEZING POINT: -97.7 C
VAPOR DENSITY (AIR =1): 1.11
SPECIFIC GRAVITY (H20 -1): @ 20 C 0.792
EVAPORATION RATE: (BUAC =1) CA 5
SOLUBILITY IN WATER: O 20 C COMPLETE
STABILITY: STABLE
HAZARDOUS POLYMERIZATION: NOT EXPECTED TO OCCUR,
APPEARANCE AND ODOR: A CLEAR, COLORLESS LIQUID WITH A SLIGHT ALCOHOLIC ODOR
CONDITIONS TO AVOID: HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
MATERIALS TO AVOID: STRONG OXIDIZING AGENTS AND REACTIVE METALS WHICH WILL
DISPLACE HYDROGEN.
HAZARDOUS DECOMPOSITION PRODUCTS: INCOMPLETE COMBUSTION CAN GENERATE CARBON
MONOXIDE AND OTHER TOXIC VAPORS SUCH AS FORI4ALDEHYDE,
III, FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD): 12 C (TAG CLOSED CUP)
AUTO IGNITION TEMPERATURE: 385 C
FLAMMABLE LIMITS IN AIR % BY VOLUME: LOWER LIMIT: 6.0 UPPER LIMIT: 36.5
UNUSUAL FIRE AND EXPLOSION HAZARDS: MAY BURN WITH AN INVISIBLE FLAME.
MIXTURES WITH WATER AS LOW AS 21% BY VOLUME ARE STILL FLAMMABLE (FLASH POINT
BELOW 37.8 C). UNDER SOME CIRCUMSTANCES CAN CORRODE CERTAIN METALS, INCLUDING
ALUMINUM AND ZINC, AND GENERATE HYDROGEN GAS.
PAGE 1
-EXTINGUISHING MEDIA: CARBON DIOXIDE, [IRY CHEMICAL, ALCOHOL FOAM, WATER MIST,
OR FOG.
SPECIAL FIRE FIGHTING PROCEDURES: WEAR FULL PROTECTIVE CLOTHING AND SELF -
CONTAINED BREATHING APPARATUS, HEAT WILL BUILD PRESSURE AND MAY RUPTURE CLOSED
STORAGE CONTAINERS. KEEP FIRE - EXPOSED CONTAINERS COOL WITH WATER SPRAY,
IV. HAZARDOUS COMPONENTS
METHANOL WT.% CA 100 TLV 200 PPM (SKIN) CAS NO. 67--56 -1
V. HEALTH HAZARDS
OCCUPATIONAL EXPOSURE LIMITS
OSHA TWA
STEL
CEILING
ACGIH TLV -TWA
TLV -STEL
NIOSH 10 -HOUR TWA
STEL
CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
200 PPM (SKIN)
250 PPM OSHA / NIOSH 25,000 PPM
NOT LISTED
ODOR THRESHOLD
200 PPM (SKIN)
250 PPM NSC 10 PPM
NIOSH 2,000 PPM
200 PPM (SKIN)
250 PPM
CARCINOGENIC DATA
METHANOL IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACCIH._
PRIMARY ROUTES OF ENTRY
METHANOL MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION,
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE DROWSINESS AND INTOXICATION, HEADACHE, VISUAL
DISTURBANCE LEADING TO BLINDNESS, COUGHING AND SHORTNESS OF BREATH, COLLAPSE
AND DEATH AT HIGH CONCENTRATIONS.
EYE CONTACT: LIQUID CAN CAUSE MODERATE BURNING, WATERING, SWELLING, AND
REDNESS; HIGH VAPOR CONCENTRATION (GREATER THAN 2,000 PPM) MAY CAUSE SAME
SYMPTOMS.
SKIN CONTACT: THIS SUBSTANCE MAY BE ABSORBED THROUGH INTACT SKIN AND PRODUCE
TOXIC EFFECTS. EXTENSIVE, REPEATED AND /OR PROLONGED SKIN CONTACT CAN CAUSE
BURNING, ITCHING, REDNESS, OR BLISTERS,
INGESTION: CAUSES BURNING OF THE GASTROINTESTINAL TRACT AND TOXIC EFFECTS.
SWALLOWING MORE THAN 2 OUNCES OF METHANOL CAN CAUSE DEATH.
EFFECTS OF OVEREXPOSURE
MILD POISONING IS CHARACTERIZED BY FATIGUE, NAUSEA, HEADACHE, AND DELAYED
VISUAL BLURRING. MODERATE INTOXICATION RESULTS IN SEVERE DEPRESSION.
TEMPORARY OR PERMANENT BLINDNESS MAY FOLLOW IN 2 -6 DAYS, IN SEVERE POISONING,
SYMPTOMS PROGRESS TO RAPID, SHALLOW RESPIRATION, CYANOSIS, COMA, HYPOTENSION,
DILATED PUPILS, AND VISUAL DISTURBANCE. DEATH MAY RESULT FROM RESPIRATORY
FAILURE.
PAGE 2
~MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS WITH DISEASES OF EYES, LIVER, KIDNEYS,
AND LUNGS.
EMERGENCY
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR, IF NOT BREATHING, ADMINISTER
MOUTH-TO-MOUTH RESCUE BREATHING. IF THERE IS NO PULSE, ADMINISTER
CARDIOPULMONARY RESUSCITATION (CPR). CONTACT PHYSICIAN IMMEDIATELY.
EYE CONTACT: RINSE IOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
EMERGENCY MEDICAL ASSISTANCE,
SKIN CONTACT: FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER, REMOVE CONTAMINATED CLOTHING AND SHOES. WASH CLOTHING
BEFORE RE-USE, AND DISCARD CONTAMINATED SHOES. GET EMERGENCY MEDICAL
ASSISTANCE.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT PHYSICIAN
IMMEDIATELY, NEVER INDUCE VOMITING OR GIVE ANYTHING BY MOUTH TO A VICTIM
UNCONSCIOUS OR HAVING CONVULSIONS.
NOTE TO OR MASSIVE ' OBSERVE VICTIM
AS AN INPATIENT BECAUSE SLOW METABOLISM CAUSES A LATENT PERIOD OF 24 HOURS
BETWEEN EXPOSURE AND ACIDOSIS AND BLINDNESS.
VI, SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE FIRE HAZARDS.
THE CHOICE OF VENTILATION EQUIPMENT, EITHER LOCAL OR GENERAL, WILL DEPEND ON
THE CONDITIONS OF USE, QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS,
RESPIRATORY: USE APPROVED RESPIRATOR EQUIPMENT. FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIPMENT (AIR-
PURIFYING, AIR-SUPPLIED, OR SELF-CONTAINED BREATHING APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR FACE
SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL AND CONDITIONS OF
USE.
SKIN: PROTECTIVE OF MATERIAL
MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER REQUIREMENTS, GENERALLY,
NEOPRENE, NITRILE RUBBER, OR RUBBER OFFERS ACCEPTABLE CHEMICAL RESISTANCE.
INDIVIDUALS WHO ARE SPECIFICALLY SENSITIVE TO METHANOL MAY REQUIRE
ADDITIONAL PROTECTIVE EQUIPMENT.
STORAGE: METHANOL SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND DIRECT
SUNLIGHT, PROPER STORAGE OF METHANOL MUST BE DETERMINED BASED ON OTHER
MATERIALS STORED AND THEIR HAZARDS AND POTENTIAL CHEMICAL INCOMPATIBILITY, IN
GENERAL, METHANOL SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND SECURE
FLAMMABLE LIQUID STORAGE ROOM.
OTHER: EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD DE AVAILABLE IN
THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND AND BOND METAL CONTAINERS TO
MINIMIZE STATIC SPARKS.
PAGE 3
•VII. SPILL AND DISPOSAL DATA
SPILL CONTROL: PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT. ABSORB SPILLED MATERIAL IN AN ABSORBENT
RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE LOCATION FOR DISPOSAL BY
APPROVED METHODS. IF RELEASED TO THE ENVIRONMENT, COMPLY WITH ALL REGULATORY
NOTIFICATION REQUIREMENTS, CERCLA REPORTABLE QUANTITY: 5,000 POUNDS,
WASTE DISPOSAL: DISPOSE OF METHANOL AS AN EPA HAZARDOUS WASTE. CONTACT STATE
ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS WASTE DISPOSAL
FACILITIES AND APPLICABLE REGULATIONS. HAZARDOUS WASTE NUMBER: Ui54
(IGNITABLE); F003 (IGNITABLE).
HAZARD CLASSIFICATION
IMMEDIATE HEALTH: YES
DELAYED HEALTH: YES
FIRE: YES
SUDDEN RELEASE: NO
REACTIVE: NO
CHEMICAL LISTINGS
EXTREMELY HAZARDOUS SUBSTANCES: NO
CERCLA HAZARDOUS SUBSTANCES: YES
TOXIC CHEMICALS: YES
METHANOL IS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III
OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND 40CFR
PART 372, THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE 1%
CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "FUNDAMENTALS OF INDUSTRIAL HYGIENE," 3RD
ED., 1988)
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF. BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY, IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SUCH INFORMATION. REFERS, BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VIM 07/09/98"
y
,,, BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
• MATERIAL SAFETY DATA SHEET
DIMETHYL FORMAMIDE
REVISION DATE: DECEMBER, 1993
REVISION NO: 1
INFORMATION /EMERGENCY TELEPHONE NUMBER 616,726.3171
CHEMTREC TELEPHONE NUMBER 800.424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME:
CHEMICAL FAMILY:
SYNONYMS:
DOT PROPER SHIPPING NAME:
DOT HAZARD CLASS:
DOT IDENTIFICATION NUMBER:
II. PHYSICAL AND CHEMICAL
BOILING POINT, 760 MM MG:
VAPOR PRESSURE AT 20 C:
X VOLATILES BY VOLUME:
FREEZING POINT:
VAPOR DENSITY (AIR =1):
SPECIFIC GRAVITY (H20 =1):
EVAPORATION RATE:
SOLUBILITY IN WATER:
STABILITY:
HAZARDOUS POLYMERIZATION:
APPEARANCE AND ODOR:
CONDITIONS TO AVOID:
MATERIALS TO AVOID:
HAZARDOUS DECOMPOSITION
PRODUCTS:
DIMETHYL FORMAMIDE MOLECULAR WEIGHT: 73.10
ALKYL AMIDE FORMULA: C3H7NO
DMF, N,N- DIMETI- IYLFORMAMIDE
N,N- DIMETHYLFORMAMIDE
FLAMMABLE LIQUID, HAZARD CLASS 3, P.G. III
UN2265 CAS NUMBER: 68 -12 -2
DATA
153 C
2.7 MM HG
CA 100
-60.4 C
2.5
e 20 C 0.949
(BUAC =1) CA 0.2
@ 20 C COMPLETE
STABLE
NOT EXPECTED TO OCCUR
CLEAR, COLORLESS LIQUID WITH A SLIGHT AMINE -LIKE
ODOR.
HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
STRONG OXIDIZERS, HALOGENATED COMPOUNDS AND IRON,
ALKYL ALUMINUMS, INORGANIC NITRATES, AND CARRON
TETRACHLORIDE.
INCOMPLETE COMBUSTION CAN GENERATE CARBON MONOXIDE,
DIMETI- IYLAMINE, NITROGEN OXIDES, AND OTHER TOXIC
VAPORS. THERMAL. DECOMPOSITION MAY OCCUR AT
TEMPERATURES EXCEEDING 350 C.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT(TEST METHOD): 58 C(TAG CLOSED CUP) AUTO IGNITION TEMPERATURE: 445 C
FLAMMABLE LIMITS IN AIR X BY VOLUME: LOWER LIMIT 2.2 UPPER LIMIT: 15.2
UNUSUAL FIRE AND EXPLOSION HAZARDS: NONE, OTHER THAN COMBUSTIBILITY.
PAGE 1
' EXTINGUISHING MEDIA:
SPECIAL FIRE FIGHTING PROCEDURES:
IV. HAZARDOUS COMPONENTS
DIMETHYL FORMAMIDE
V. HEALTH HAZARDS
CARBON DIOXIDE, DRY CHEMICAL OR ALCOHOL
FOAM.
WEAR FULL PROTECTIVE CLOTHING AND SELF-
CONTAINED BREATHING APPARATUS, HEAT WILL
BUILD PRESSURE AND MAY RUPTURE CLOSED
STORAGE CONTAINERS. KEEP FIRE - EXPOSED
CONTAINERS COOL WITH WATER SPRAY.
LJT . % CA 100
TLV 10 PPM (SKIN)
CAS NO. 68 -12 -2
OCCUPATIONAL EXPOSURE LIMITS CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
OSHA /NIOSH 3,500 PPM
ODOR THRESHOLD
OSHA TWA 10 PPM (SKIN)
STEL NOT LISTED
CEILING NOT LISTED
ACGIH TLV -TWA 10 PPM (SKIN)
TLV -STEL NOT LISTED
NIOSH TWA 10 PPM (SKIN)
NSC 20 PPM
NIOSH 100 PPM
CARCINOGENIC DATA
DIMETHYL FORMAMIDE IS LISTED AS A SUSPECTED CARCINOGEN BY IARC,
PRIMARY ROUTES OF ENTRY
DIMETHYL FORMAMIDE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION,
AND INGESTION,
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN DIZZINESS, HEADACHE, NAUSEA, FLUSHING OF THE FACE,
ABDOMINAL_ SPASMS, AND IRRITATION TO THE UPPER RESPIRATORY
TRACT. LIVER AND KIDNEY INJURY IS POSSIBLE FROM REPEATED OR
PROLONGED EXPOSURES,
EYE CONTACT:
SKIN CONTACT:
LIQUID AND HIGH VAPOR CONCENTRATION WILL BE IRRITATING, .
PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE IRRITATION AND
DERMATITIS. 3IMETHYL FORMAMIDE IS READILY ABSORBED THROUGH THE
SKIN WITH SYSTEMIC EFFECTS SIMILAR TO INHALATION.
INGESTION: CAN CAUSE GASTROINTESTINAL TRACT DISCOMFORT, SWALLOWING MORE
THAN 50 GRAMS OF DIMETHYL FORMAMIDE CAN CAUSE DEATH.
EFFECTS OF OVEREXPOSURE
DIMETHYL FORMAMIDE IS AN EYE AND MUCOUS MEMBRANE IRRITANT, PRIMARY. SKIN
IRRITANT, AND HEPATOTOXIN, ACUTE EXPOSURE CAUSES DIZZINESS, NAUSEA, VOMITING,
AND SEVERE ABDOMINAL_ SPASMS, CHRONIC INHALATION CAN CAUSE LIVER, KIDNEY., AND
CARDIOVASCULAR DAMAGE.
PAGE 2
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS WITH DISEASE OF THE LIVER AND KIDNEY,
AND THOSE SUSCEPTIBLE TO DERMATITIS, SIMULTANEOUS EXPOSURE TO DIMETHYL
FORMAMIDE AND ALCOHOL CAUSES FACIAL FLUSHING AND PALPITATION.
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR, IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING, IF THERE IS NO PULSE,
ADMINISTER CARDIOPULMONARY RESUSCITATION (CPR), CONTACT
PHYSICIAN IMMEDIATELY.
RINSE WITH COPIOUS AMOUN1S OF WATER FOR AT LEAST 15 MINUTES,
GET EMERGENCY MEDICAL ASSISTANCE.
EYE CONTACT:
SKIN CONTACT:
INGESTION
FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN.
WITH SOAP AND WATER, REMOVE CONTAMINATED CLOTHING AND SHOES.
WASH CLOTHING BEFORE RE -USE, AND DISCARD CONTAMINATED SHOES.
GET EMERGENCY MEDICAL ASSISTANCE.
CALL. LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT
PHYSICIAN IMMEDIATELY, NEVER INDUCE VOMITENG OR GIVE ANYTHING
BY MOUTH TO A VICTIM UNCONSCIOUS OR HAVING CONVULSIONS,
VI. SAFETY MEASURES AND EQUIPMENT
VENTILATION:
RESPIRATORY:
EYES:
SKIN:
STORAGE:
OTHER:
ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE
FIRE HAZARDS. THE CHOICE OF VENTILATION EQUIPMENT, EITHER
LOCAL OR GENERAL, WILL DEPEND ON THE CONDITIONS OF USE,
QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS.
USE APPROVED RESPIRATOR EQUIPMENT. FOLLOW NIOSH AND EQ.LIIPMENT
MANUFACTURER'S RECOMMENOATIONS TO OETERMTNE APPROPRIATE EQUIP-
MENT (AIR- PURIFYING, AIR - SUPPLIED, OR SELF- CONTAINED BREATHING
APPARATUS).
SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR
FACE SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL
AND CONDITIONS OF USE.
PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED. THE CHOICE OF
MATERIAL MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER
REQUIREMENTS.' GENERALLY, BUTYL RUBBER, NATURAL RUBBER, OR
NEOPRENE OFFERS ACCEPTABLE CHEMICAL RESISTANCE. INDIVIDUALS
WHO ARE ACUTELY AND SPECIFICALLY SENSITIVE TO. DIMETHYL_
FORMAMIDE MAY REQUIRE ADDITIONAL PROTECTIVE EQUIPMENT.
DIMETHYL FORMAMIOE SHOULD BE PROTECTED FROM TEMPERATURE
EXTREMES AND DIRECT SUNL.IGHT. PROPER STORAGE OF DIMETHYL
FORMAMIDE MUST BE DETERMINED BASED ON OTHER MATERIALS STORED
AND THEIR HAZARDS AND POTENTIAL CHEMICAL INCOMPATIBILITY, IN
GENERAL, DIMETHYL FORMAMIDE SHOULD BE STORED IN AN ACCEPTABLY
PROTECTED AND SECURE TOXIC STORAGE ROOM,
EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD BE
AVAILABLE IN THE VICINITY OF ANY POTENTIAL EXPOSURE, GROUND
AND BONO METAL CONTAINERS TO MINIMIZE STATIC SPARKS.
PAGE 3
- VII. SPILL AND DISPOSAL DATA
SPILL CONTROL: PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQ.UIPMF.NT, ABSORB SPILLED MATERIAL IN AN
ABSORBENT RECOMMENDED FOR SOLVENT SPILLS AND REMOVE TO A SAFE
LOCATION FOR DISPOSAL BY APPROVED METHODS, IF RELEASED TO THE
ENVIRONMENT, COMPLY WITH ALL REGULATORY NOTIFICATION REQUIRE-
MENTS, CERCLA REPORTABLE QUANTITY:
WASTE DISPOSAL: DISPOSE OF DIMETHYL FORMAMIDE AS AN EPA HAZARDOUS WASTE.
CONTACT'STATE ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED
HAZARDOUS WASTE DISPOSAL FACILITIES AND APPLICABLE REGULATIONS.
HAZARDOUS WASTE NUMBER: 0001 (IGNITABLE).
HAZARD CLASSIFICATION CHEMICAL LISTINGS
IMMEDIATE HEALTH: YES EXTREMELY HAZARDOUS SUBSTANCES: NO
DELAYED HEALTH: YES CERCLA HAZARDOUS SUBSTANCES: NO
FIRE: YES TOXIC CHEMICALS: NO
SUDDEN RELEASE: NO
REACTIVE: NO
DIMETHYL_ FORMAMIDE IS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF
TITLE III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA)
AND 40CFR PART 372. THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL
ABOVE 1% CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ( "FUNDAMENTALS OF INDUSTRIAL HYGIENE," 3RD
ED., 1988)
BURDICK & JACKSON'S DISCLAIMER: THE II.IFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF. BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, TIIE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS
OR IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY
OTHER NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED TN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WIIICII SUCI•I INFORMATION REFERS. BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT,
ANY OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THL USE OF,
OR RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
MATERIAL SAFETY DATA SHEET
EM SCIENCE
11. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
MANUFACTURER
EM SCIENCE
A DIVISION OF EM INDUSTRIES
P.O. BOX 70
480 DEMOCRAT RD.
GIBBSTOWN, N.J. 08027
CATALOG NUMBER(S):
TX0277 TX0278
TX0280P TX0280T
TX0284
TX0279
TX0281
PREPARATION DATE.: 02/11/97
DATE WAS PRINTED.: MAY 15, 1997
INFORMATION PHONE NUMBER.: 609- 423 -6300
HOURS: MON. TO FRI. 8 :30 -5
CHEMTREC EMERGENCY NUMBER: 800 -424 -9300
HOURS: 24 HRS A DAY
TX0279AP
TX0202
PRODUCT
TETRAHYDROFURAN
SYNONYMS
THF; DIETHYLENE OXIDE; TETRAMETHYLENE OXIDE
CHEMICAL FAMILY..:
CYCLIC ETHER
FORMULA
C4H80
MOLECULAR WEIGHT.:
72.11
2. COMPOSITION / INFORMATION ON INGREDIENTS
COMPONENT CAS 1
TX0200 TX0280AG
TX0282AG TX0282P
APPRZ
TETRAHYOROFURAN
109 -99 -9 100X
3. HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
EXTREMELY FLAMMABLE LIQUID AND VAPOR.
TENDS TO FORM EXPLOSIVE PEROXIDES ESPECIALLY WHEN ANHYDROUS.
CAUSES IRRITATION OF EYES, NOSE AND THROAT.
MAY CAUSE EYE INJURY.
MAY CAUSE DAMAGE TO NERVOUS AND RESPIRATORY SYSTEMS, KIDNEYS AND
LIVER.
APPEARANCE
MSDS (CONTINUED) - TX0278 PAGE 4 1
• COLORLESS LIQUID; ETHEREAL ODOR
POTENTIAL HEALTH EFFECTS (ACUTE AND CHRONIC)
SYMPTOMS OF EXPOSURE:
IRRITATING TO EYES (CAUSING BLURRED VISION), SKIN, RESPIRATORY
TRACT (ANESTHETIC EFFECT, HEADACHE)
MAY CAUSE DAMAGE TO NERVOUS AND RESPIRATORY SYSTEMS, KIDNEYS AND
LIVER.
MAY CAUSE EYE BURNS, .
MEDICAL_ COND. AGGRAVATED BY EXPOSURE:
PRE - EXISTING SKIN DISORDERS OR EYE
PROBLEMS OR IMPAIRED LIVER OR KIDNEY FUNCTIONS,
ROUTES OF ENTRY
INHALATION, INGESTION
CARCINOGENICITY............ ....... O
THE MATERIAL IS NOT LISTED (IARC, NTP, OSHA) AS CANCER CAUSING
AGENT.
4. FIRST AID MEASURES
EMERGENCY FIRST AID:
GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE.
SKIN: IMMEDIATELY FLUSH THOROUGHLY WITH LARGE AMOUNTS OF WATER.
EYES: IMMEDIATELY FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15
MINUTES.
INHALATION: REMOVE TO FRESH AIR; GIVE ARTIFICIAL RESPIRATION IF
BREATHING HAS STOPPED.
INGESTION: DO NOT INDUCE VOMITING; IF CONSCIOUS, GIVE WATER
FREELY AND GET MEDICAL ATTENTION,
15. FIRE FIGHTING MEASURES
FLASH POINT (F)..........: 6F (TCC)
FLAMMABLE LIMITS LEL (X).: 2
FLAMMABLE LIMITS UEL (X).: 11.8
EXTINGUISHING MEDIA
USE CARBON DIOXIDE OR DRY CHEMICAL. USE WATER TO COOL FIRE- EXPOSED
CONTAINERS AND DISPERSE VAPORS,
FIRE FIGHTING PROCEDURES.:
WEAR SELF - CONTAINED BREATHING APPARATUS AND PROTECTIVE CLOTHING..
FIRE & EXPLOSION HAZARDS.:
DANGEROUS FIRE AND EXPLOSIVE HAZARD.
MSDS (CONTINUED) - TX0278
PAGE 1 2
EXPLOSIVE PEROXIDES MAY FORM AFTER LONG STORAGE OR EXPOSURE
TO AIR AND LIGHT.
THF CAN FORM HEAT SENSITIVE PEROXIDE WHICH MAY EXPLODE ON
CONCENTRATION BY DISTILLATION OR DRYING, DO NOT DISTILL OR
ALLOW THF, OR SOLUTIONS CONTAINING THF, TO DRY IF TESTS SHOW
MORE THAN 0.05% THF PEROXIDE PRESENT, TO AVOID A POSSIBLE
EXPLOSION, THF SHOULD NEVER BE DISTILLED TO DRYNESS.
VAPOR CAN TRAVEL DISTANCES TO IGNITION SOURCE AND FLASH BACK,
6. ACCIDENTAL RELEASE MEASURES
SPILL RESPONSE:
EVACUATE THE AREA OF ALL UNNECESSARY PERSONNEL.
WEAR SUITABLE PROTECTIVE EQUIPMENT LISTED UNDER EXPOSURE /
PERSONAL PROTECTION.
ELIMINATE ANY IGNITION SOURCES UNTIL THE AREA I5 DETERMINED TO BE
FREE FROM EXPLOSION OR FIRE HAZARDS.
CONTAIN THE RELEASE AND ELIMINATE ITS SOURCE, IF THIS CAN BE DONE
WITHOUT RISK.
TAKE UP AND CONTAINERIZE FOR PROPER DISPOSAL AS DESCRIBED UNDER
DISPOSAL.
COMPLY WITH FEDERAL, STATE, AND LOCAL REGULATIONS ON REPORTING
RELEASES, REFER TO REGULATORY INFORMATION FOR REPORTABLE
QUANTITY AND OTHER REGULATORY DATA.
EM SCIENCE RECOMMENDS SPILL -X ABSORBENT AGENTS FOR VARIOUS TYPES
OF SPILLS. ADDITIONAL INFORMATION ON THE SPILL -X PRODUCTS CAN BE
PROVIDED THROUGH THE EM SCIENCE TECHNICAL SERVICE DEPARTMENT
(609) 423 -6300,
THE FOLLOWING EM SCIENCE SPILL. -X ABSORBENT IS RECOMMENDED FOR
THIS PRODUCT:
SX0863 SOLVENT SPILL TREATMENT KIT
7. HANDLING AND STORAGE
HANDLING & STORAGE:
KEEP CONTAINER CLOSED.
STORE IN A COOL AREA AWAY FROM IGNITION SOURCES AND OXIDIZERS,
CHECK PEROXIDE CONTENT BEFORE HEATING MATERIAL,
00 NOT GET IN EYES, ON SKIN, OR ON CLOTHING.
DO NOT BREATHE VAPOR.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
ENGINEERING CONTROLS AND PERSONAL PROTECTIVE EQUIPMENT:
VENTILATION, RESPIRATORY PROTECTION, PROTECTIVE CLOTHING, EYE PROTECTION
RESPIRATORY PROTECTION: IF WORKPLACE EXPOSURE LIMIT(S) OF PRODUCT
MSDS (CONTINUED) - TX0 270 PAGE 1 3
OR ANY COMPONENT IS EXCEEDED (SEE TLV /PEL), A NIOSH /MSI-IA APPROVED
AIR SUPPLIED RESPIRATOR IS ADVISED IN ABSENCE OF PROPER
ENVIRONMENTAL CONTROL. OSHA REGULATIONS ALSO PERMIT OTHER
NIOSH /MSHA RESPIRATORS (NEGATIVE PRESSURE TYPE) UNDER SPECIFIED
CONDITIONS (SEE YOUR SAFETY EQUIPMENT SUPPLIER), ENGINEERING
AND /OR ADMINISTRATIVE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE
EXPOSURE.
MATERIAL SHOULD BE HANDLED OR TRANSFERRED IN AN APPROVED FUME
HOOD OR WITH ADEQUATE VENTILATION.
PROTECTIVE GLOVES (PVA OR EQUIVALENT) SHOULD
BE WORN TO PREVENT SKIN CONTACT.
COVERALL CHEMICAL SPLASH GOGGLES MUST BE WORN AT ALL TIMES.
WORK / HYGENIC PRACTICES:
WASH THOROUGHLY AFTER HANDLING.
DO NOT TAKE INTERNALLY.
EYE WASH AND SAFETY EQUIPMENT SHOULD DE READILY AVAILABLE,
EXPOSURE GUIDELINES
OSHA - PEL:
TWA STEL . CL
COMPONENT PPM MG /M3 PPM MG /M3 PPM MG /M3 SKIN
TETRAHYDROFURAN
200 590 250 735
ACGIH - TLV:
TWA STEL CL
COMPONENT PPM MG /M3 PPM MG /M3 PPM MG /M3 SKIN
TETRAHYDROFURAN
200 590 250 737
9. PHYSICAL AND CHEMICAL PROPERTIES
BOILING POINT (C 760 MMHG).: 65C
MELTING POINT (C) -108.5C
SPECIFIC GRAVITY (H20 = 1).: 0,888
VAPOR PRESSURE (MM HG)..... :' 114 15C
PERCENT VOLATILE BY VOL (X) : 100X
VAPOR DENSITY (AIR = 1) '' 5
EVAPORATION RATE (BOAC = 1): 8.0
SOLUBILITY IN WATER (%) • SOLUBLE
APPEARANCE
COLORLESS LIQUID; ETHEREAL ODOR
10. STABILITY AND REACTIVITY
MSDS (CONTINUED) - TX0278 PAGE t 4
STABILITY YES
HAZARDOUS POLYMERIZATION:
DOES NOT OCCUR
HAZARDOUS DECOMPOSITION,
COX
CONDITIONS TO AVOID
HEAT; CONTACT WITH IGNITION SOURCES; EVAPORATION TO DRYNESS OR
NEAR DRYNESS
MATERIALS TO AVOID
( ) WATER
( ) ACIDS
( ) BASES
( ) CORROSIVES
( ) OXIDIZERS
(X) OTHER :
STRONG OXIDIZERS, SODIUM ALUMINUM HYDRIDE, EXCESS OF STRONG
CAUSTIC, LITHIUM ALUMINUM HYDRIDE
11. TOXICOLOGICAL INFORMATION
TOXICITY DATA:
IHL -HMN TCLO: 25000 PPM
ORL -RAT LD50: 1650 MG /KG
IHL -RAT LD50: 21000 PPM /3H
TOXICOLOGICAL FINDINGS:
TESTS ON LABORATORY ANIMALS INDICATE MATERIAL MAY PRODUCE ADVERSE
MUTAGENIC AND REPRODUCTIVE EFFECTS.
CITED IN REGISTRY OF TOXIC EFFECTS OF CHEMICAL SUBSTANCES.(RTECS)
12, DISPOSAL CONSIDERATIONS
EPA WASTE NUMBERS: U213 D001
TREATMENT:
INCINERATION, FUELS BLENDING OR RECYCLE. CONTACT YOUR LOCAL
PERMITTED WASTE DISPOSAL SITE (TSO) FOR PERMISSIBLE TREATMENT
SITES.
ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSO) TO ASSURE
COMPLIANCE WITH ALL CURRENT LOCAL, STATE AND FEDERAL REGULATIONS.
13. TRANSPORT INFORMMATION
DOT PROPER SHIPPING NAME,..:
MSDS (CONTINUED) - TX0278
PAGE t 5
' TETRAHYDROFURAN
DOT ID NUMBER
UN2056
14. REGULATORY INFORMATION
TSCA STATEMENT ...
.
THE CAS NUMBER OF THIS PRODUCT IS LISTED ON THE TSCA INVENTORY.
COMPONENT
SARA SARA CERCLA
EHS EHS TPQ RQ
(302) (LBS) (LBS)
TETRAHYDROFURAN
1000
OSHA SARA (EMINIMIS
COMPONENT FLOOR LIST 313 FOR SARA 313
(X)
TETRAHYDROFURAN
15. OTHER INFORMATION
COMMENTS:
NONE
NFPA HAZARD RATINGS:
HEALTH : 2
FLAMMABILITY : 3
REACTIVITY : 1
SPECIAL HAZARDS
REVISION HISTORY:
08/01/81 04/15/86 06/08/87 10/27/89 01/30/91 03/01/91 07 /26/94
04/05/95 07/07/95 08/28495 02/15/96
= REVISED SECTION
N/A = NOT AVAILABLE
N/E = NONE ESTABLISHED
THE STATEMENTS CONTAINED HEREIN ARE OFFERED FOR INFORMATIONAL PURPOSES
ONLY AND ARE BASED UPON TECI•HNICAL DATA THAT EM SCIENCE BELIEVES TO BE
ACCURATE. TT IS INTENDED FOR USE ONLY BY PERSONS HAVING THE NECESSARY
TECHNICAL SKILL AND AT THEIR OWN DESCRETTON AND RISK. SINCE CONDITIONS
AND MANNER OF USE ARE OUTSIDE OUR CONTROL, WE MAKE NO WARRANTY, EXPRESS
MSDS (CONTINUED) - TX0278 PAGE t 6
-- OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE.
MSOS - TX0278 PAGE t 7
"ISSUED BY VWR 07/09/98"
- BURDICK & JACKSON, INC.
1953 SOUTH HARVEY STREET
MUSKEGON, MI 49442 USA
MATERIAL SAFETY DATA SHEET
TOLUENE
REVISION DATE: DECEMBER, 1993
REVISION NO: 1
INFORMATION /EMERGENCY TELEPHONE NUMBER 616.726.3171
CHEMTREC TELEPHONE NUMBER 800.424.9300
CANADIAN EMERGENCY TELEPHONE NUMBER 613.996.6666
I. IDENTIFICATION
CHEMICAL NAME: TOLUENE
CHEMICAL FAMILY: AROMATIC HYDROCARBON
SYNONYMS: TOLUOL, METHYLBENZENE
DOT PROPER SHIPPING NAME: TOLUENE
DOT HAZARD CLASS: FLAMMABLE LIQUID, HAZARD CLASS 3, P.G, II
DOT IDENTIFICATION.NUMBER: UN1294
MOLECULAR WEIGHT: 92.14
FORMULA: C7H8
CAS NUMBER: 108 -88 -3
II. PHYSICAL AND CHEMICAL DATA
BOILING POINT, 760 MM 116: 110.62 C
VAPOR PRESSURE AT 20 C: 28.5 MM HG
VOLATILES BY VOLUME: CA 100
FREEZING POINT: -94.99 C
VAPOR DENSITY (AIR =1): 3.2
SPECIFIC GRAVITY (H20 =1): O 20 C 0.867
EVAPORATION RATE: (BUAC =1) CA 2
SOLUBILITY IN WATER: 0 20 C 0.074%
STABILITY: STABLE
HAZARDOUS POLYMERIZATION: NO EXPECTED TO OCCUR.
APPEARANCE AND ODOR: CLEAR, COLORLESS LIQUID WITI -I A SWEET, PUNGENT ODOR,
CONDITIONS TO AVOID: HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS, AND POOR
VENTILATION.
MATERIALS TO AVOID: STRONG OXIDIZING AGENTS AND STRONG ACIDS.
HAZARDOUS DECOMPOSITION PRODUCTS: INCOMPLETE COMBUSTION CAN GENERATE CARBON
MONOXIDE AND OTHER TOXIC VAPORS.
III. FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (TEST METHOD): 2 C (TAG CLOSED CUP)
AUTO IGNITION TEMPERATURE: 480 C
FLAMMABLE LIMITS IN AIR X BY VOLUME: LOWER LIMIT: 1.2 UPPER LIMIT: 7.1
UNUSUAL FIRE AND EXPLOSION HAZARDS: VOLATILE AND FLAMMABLE.
EXTINGUISHING MEDIA: CARBON DIOXIDE, DRY CHEMICAL, AND FOAM,
SPECIAL FIRE FIGHTING PROCEDURES: WATER WILL NOT BE EFFECTIVE IN EXTINGUISHING
A FIRE AND MAY SPREAD IT, BUT A WATER SPRAY CAN RE USED TO COOL EXPOSED
CONTAINERS, WEAR FULL PROTECTIVE CLOTHING AND SELF - CONTAINED BREATHING
APPARATUS. HEAT WILL BUILD PRESSURE AND RUPTURE CLOSED STORAGE CONTAINERS.
PAGE 1
IV. HAZARDOUS COMPONENTS
TOLUENE WT.% CA 100
V. HEALTH HAZARDS
OCCUPATIONAL EXPOSURE LIMITS
OSHA TWA
STEL
CEILING
ACGIH TLV -TWA
TLV -STEL
NIOSH 10 -HOUR TWA
STEL
100 PPM
150 PPM
NOT LISTED
100 PPM
150 PPM
100 PPM
150 PPM
TLV 100 PPM CAS NO. 108 -88 -3
CONCENTRATION IMMEDIATELY
DANGEROUS TO HEALTH
OSHA / NIOSH 2,000 PPM
ODOR THRESHOLD
NSC 1 PPM
NIOSH 10 -15 PPM
CARCINOGENIC DATA
TOLUENE IS NOT LISTED AS A CARCINOGEN BY IARC, NTP, OSHA, OR ACGIH. RTEC
REPORTS MUTAGENIC EFFECTS ON HUMANS AND TERATOGENIC EFFECTS ON ANIMALS.
PRIMARY ROUTES OF ENTRY
TOLUENE MAY EXERT ITS EFFECTS THROUGH INHALATION, SKIN ABSORPTION, AND
INGESTION.
INDUSTRIAL EXPOSURE: ROUTE OF EXPOSURE /SIGNS AND SYMPTOMS
INHALATION: EXPOSURE CAN CAUSE ANESTHESIA, NAUSEA, DIZZINESS AND RESPIRATORY
TRACT IRRITATION,
EYE CONTACT: LIQUID AND HIGH VAPOR CONCENTRATION WILL CAUSE IRRITATION AND
POSSIBLE CORNEAL DAMAGE,
SKIN CONTACT: PROLONGED OR REPEATED SKIP! CONTACT CAN CAUSE IRRITATION AND
DERMATITIS THROUGH DEFATTING OF SKIN.
INGESTION: CAUSES IRRITATION OF THE GASTROINTESTINAL. TRACT AND MAY CAUSE
SYSTEMIC EFFECTS FROM ABSORPTION.
EFFECTS OF OVEREXPOSURE
TOLUENE IS A PRIMARY SI(IN IRRITANT AND A CENTRAL NERVOUS SYSTEM DEPRESSANT.
ACUTE POISONING AFFECTS THE NERVOUS SYSTEM LEADING TO COMA. CHRONIC EXPOSURE
DEPRESSES THE BONE MARROW, BUT WITHOUT THE SEVERE OR FATAL DAMAGE PRESENT IN
BENZENE POISONING, LIVER ENLARGEMENT IS ALSO POSSIBLE. DELIBERATE
CONCENTRATION AND INHALATION CAN CAUSE LIVER, KIDNEY, AND BRAIN DAMAGE.
MEDICAL CONDITION AGGRAVATED BY EXPOSURE
PRECLUDE FROM EXPOSURE THOSE INDIVIDUALS WITH DISEASE OF EYES, LIVER, AND
CENTRAL NERVOUS SYSTEM; AND THOSE SUSCEPTIBLE TO DERMATITIS.
EMERGENCY FIRST AID
INHALATION: IMMEDIATELY REMOVE TO FRESH AIR, IF NOT BREATHING, ADMINISTER
MOUTH -TO -MOUTH RESCUE BREATHING. IF THERE IS NO PULSE, ADMINISTER
CARDIOPULMONARY RESUSCITATION (CPR), CONTACT PHYSICIAN IMMEDIATELY.
EYE CONTACT: RINSE WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
EMERGENCY MEDICAL ASSISTANCE.
PAGE 2
SKIN CONTACT: FLUSH THOROUGHLY FOR AT LEAST 15 MINUTES. WASH AFFECTED SKIN
WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND SHOES, WASH CLOTHING
BEFORE RE-USE, AND DISCARD CONTAMINATED SHOES. GET EMERGENCY MEDICAL
ASSISTANCE.
INGESTION: CALL LOCAL POISON CONTROL CENTER FOR ASSISTANCE. CONTACT PHYSICIAN
IMMEDIATELY, ASPIRATION HAZARD - 00 NOT INDUCE VOMITING.
VI, SAFETY MEASURES AND EQUIPMENT
VENTILATION: ADEQUATE VENTILATION IS REQUIRED TO PROTECT PERSONNEL FROM
EXPOSURE TO CHEMICAL VAPORS EXCEEDING THE PEL AND TO MINIMIZE FIRE HAZARDS.
THE CHOICE OF VENTILATION EQUIPMENT, EITHER LOCAL OR GENERAL, WILL DEPEND ON
THE CONDITIONS OF USE, QUANTITY OF MATERIAL, AND OTHER OPERATING PARAMETERS.
R USE APPROVED RESPIRATOR EQUIPMENT, FOLLOW NIOSH AND EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS TO DETERMINE APPROPRIATE EQUIPMENT (AIR-
PURIFYING, AIR-SUPPLIED, OR SELF-CONTAINED BREATHING APPARATUS).
EYES: SAFETY GLASSES ARE CONSIDERED MINIMUM PROTECTION. GOGGLES OR FACE
SHIELD MAY BE NECESSARY DEPENDING ON QUANTITY OF MATERIAL AND CONDITIONS OF
USE.
SKIN: PROTECTIVE GLOVES AND CLOTHING ARE RECOMMENDED. THE O MATERIAL
MUST BE BASED ON CHEMICAL RESISTANCE AND OTHER USER REQUIREMENTS, GENERALLY,
VITON OR NITRILE RUBBER OFFERS ACCEPTABLE CHEMICAL RESISTANCE. INDIVIDUALS WHO
ARE ACUTELY AND SPECIFICALLY SENSITIVE TO TOLUENE MAY REQUIRE ADDITIONAL
PROTECTIVE EQUIPMENT,
STORAGE: TOLUENE SHOULD BE PROTECTED FROM TEMPERATURE EXTREMES AND DIRECT
SUNLIGHT. PROPER STORAGE OF TOLUENE MUST BE DETERMINED BASED ON OTHER
MATERIALS STORED AND THEIR HAZARDS AND POTENTIAL CHEMICAL INCOMPATIBILITY, IN
GENERAL, TOLUENE SHOULD BE STORED IN AN ACCEPTABLY PROTECTED AND SECURE
FLAMMABLE LIQUID STORAGE ROOM.
OTHER/ EMERGENCY EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD BE AVAILABLE IN
THE VICINITY OF ANY POTENTIAL EXPOSURE. GROUND AND BOND METAL CONTAINERS TO
MINIMIZE STATIC SPARKS.
VII. SPILL AND DISPOSAL DATA
SPILL CONTROL: PROTECT FROM IGNITION. WEAR PROTECTIVE CLOTHING AND USE
APPROVED RESPIRATOR EQUIPMENT. ABSORB SPILLED MATERIAL IN AN ABSORBENT
RECOMMENDED FOR SOLVENT SPILLS AND REMOVE
APPROVED METHODS. IF RELEASED TO THE ENVIRONMENT, COMPLY WITH ALL REGULATORY
NOTIFICATION REQUIREMENTS. CERCLA REPORTABLE QUANTITY: 1,000 POUNDS,
WASTE DISPOSAL: DISPOSE OF TOLUENE AS AN EPA HAZARDOUS WASTE, CONTACT STATE
ENVIRONMENTAL AGENCY FOR LISTING OF LICENSED HAZARDOUS WASTE DISPOSAL
FACILITIES _AND _APPLICABLE ncouLA/Iono, HAZARDOUS WASTE NUMBER: U220 (TOXIC);
M005 (TOXIC, IGNITABLE),
HAZARD CLASSIFICATION
IMMEDIATE HEALTH: YES (IRRITANT)
DELAYED HEALTH: YES
FIRE: YES
SUDDEN RELEASE: NO
REACTIVE: NO
CHEMICAL LISTINGS
EXTREMELY HAZARDOUS SUBSTANCES: NO
CERCLA HAZARDOUS SUBSTANCES: YES
TOXIC CHEMICALS: YES
PAGE 3
TOLUENE IS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III OF
THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND 4OCFR PART
372, THIS PRODUCT DOES NOT CONTAIN ANY OTHER TOXIC CHEMICAL ABOVE 1X
CONCENTRATION OR A CARCINOGEN ABOVE 0.1% CONCENTRATION.
KEY
CA APPROXIMATELY
NA NOT APPLICABLE
C CEILING
STEL SHORT TERM EXPOSURE LEVEL (15 MINUTES)
TLV THRESHOLD LIMIT VALUE •
TWA TIME WEIGHTED AVERAGE
BUAC BUTYL ACETATE
CERCLA COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF
1980
NSC NATIONAL SAFETY COUNCIL ("FUNDAMENTALS OF INDUSTRIAL HYGIENE," 3RD
ED., 1988)
BURDICK & JACKSON'S DISCLAIMER: THE INFORMATION AND RECOMMENDATIONS PRESENTED
IN THIS MATERIAL SAFETY DATA SHEET ARE BASED ON SOURCES BELIEVED TO BE RELIABLE
ON THE DATE HEREOF, BURDICK & JACKSON MAKES NO REPRESENTATION ON ITS
COMPLETENESS OR ACCURACY. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE
PRODUCT'S SUITABILITY FOR ITS INTENDED USE, THE PRODUCT'S SAFE USE, AND THE
PRODUCT'S PROPER DISPOSAL. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR
IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER
NATURE ARE MADE WITH RESPECT TO THE INFORMATION PROVIDED IN THIS MATERIAL
SAFETY DATA SHEET OR TO THE PRODUCT TO WHICH SUCH INFORMATION REFERS. BURDICK
& JACKSON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT, ANY
OTHER OR ADDITIONAL LIABILITY OR RESPONSIBILITY RESULTING FROM THE USE OF, OR
RELIANCE UPON, THIS INFORMATION.
PAGE 4 (LAST PAGE)
"ISSUED BY VWR 07/09/98"
* 4441 # #t # #tik#tt #ttt0t # #t #t #t # #t 4440: P40t #04tttttt4t444 #t #iki<04ttttt# #4440 #4tt #t ##
tilt#tttfltttMttt#tt44 CA- IDMS /DC 12.0 VERSION 00062 tUtttMttMtt #1'41#1#
# #tttttttttf #t #ttf tilt# iF t #tt#111t *tttf #ftt # #t. #Ci#tti tttftt# 44tt*ttt #t #tt #4tt # ##
##tt #tilt ## #fttt$ USER ID = 000203 #tt #4041:441# #t###
#f #t #$#t#t ## #t## REPORT ID = PRLS3146 t#t #t## # #i<#tt# #t
#tilt* #4411 ## #4141 LTERM ID = UCLT(3002 # ## #t ##fi=t #t # # #t#
#t##### #111#1$1* INFO NAME = SDCCSITO 4144 #4ir4tttttttt
t #tt #tilt # ## #tilt# TIME AND DATE OF CREATION = 17:32:49 98.190 tttttttt4 #tttttt
##### tt*t t# t ttttttt #tttt$tt.tttt#tttttttt.t 1t##t tttttt°tttt #t *.ttt #ttttt°tttttt
# #tt #hilt* # # # # # #tt tilt tilt# tt# tt# t###### tt# t# tt# t# #tt#tttttt #t ##tt#tt#t## #t # # #ftf
tttttt ##tilt##' # #t # #i 4t #41 #4 # #1tt4ttif# #011440 #hilt04000 4144140414 410 #tiF4t # # # # ##
MATERIAL SAFETY DATA SHEET
EM SCIENCE
11. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
MANUFACTURER
EM SCIENCE
A DIVISION OF EM INDUSTRIES
P.O. 00X 70
480 [DEMOCRAT RD,
GIBBSTOWN, N.J. 08027
CATALOG NUMBER(S):
XX0055 XX0055E XX0055P
PRODUCT NAME
XYLENE
SYNONYMS,.......:
XYLOL, DIMETHYLDENZENE
CHEMICAL FAMILY..:
AROMATIC HYDROCARBON
FORMULA
C6H4(CH3)2
MOLECULAR WEIGHT.:
106.17
PREPARATION DATE,: 10/10/95
DATE MSOS PRINTED.: DEC 18, 1995
INFORMATION PHONE NUMBER.: 609- 423-6300
HOURS: MON. TO FRI. 8 :30 -5
CNIr:MTREC EMERGENCY NUMBER: 0800- 424.9300
HOURS: 24 MRS A DAY
XX0055S XX0057 XX0060
2. COMPOSITION / INFORMATION ON INGREDIENTS
COMPONENT
CAS t
M- XYLENE
O- XYLENE
P- XYLENE
ETHYL BENZENE
108-38-3
95-47-6
106 -42.3
100. 41.••4
XYLENE HAS BEEN ASSIGNED CAS# 1330 - •20-7.
3. HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
APPR
42/.
19%
18%
21%
•
,FLAMMABLE LIQUID AND VAPOR,
VAPOR HARMFUL.
MAY CAUSE DAMAGE TO LUNGS, THORAX, OR SENSE ORGANS.
IRRITATING TO SKIN, EYES AND MUCOUS MEMBRANES.
APPEARANCE.....,.. . „ :
COLORLESS LIQUID; AROMATIC ODOR
POTENTIAL HEALTH EFFECTS (ACUTE AND CHRONIC)
SYMPTOMS OF EXPOSURE:
HARMFUL OR FATAL IF SWALLOWED, VAPOR HARMFUL.
CAUSES TEARING, BLURRED VISION, DIZZINESS, FATIGUE, LOSS OF APPETITE,
NAUSEA, IRRITATION OF MUCOUS MEMBRANES.
NARCOTIC AT HIGH CONCENTRATIONS,
IRRITATING TO SKIN ON PROLONGED CONTACT CAUSING FLAKY DERMATITIS
AND DEFATTING.
LIQUID AND VAPOR IRRITATING. TO EYES,
MEDICAL COND, AGGRAVATED BY EXPOSURE:
DATA NOT AVAILABLE.
ROUTES OF ENTRY
INHALATION, INGESTION
CARCINOGENICITY.. .,,
THE MATERIAL IS NOT LISTED�(IARC, NTP, OSHA) AS CANCER CAUSING
AGENT,
4, FIRST AID MEASURES
EMERGENCY FIRST AID:
GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE,.
SKIN: WASH THOROUGHLY WITH SOAP AND WATER,
EYES: IMMEDIATELY FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15
MINUTES.
INHAL.ATION: REMOVE TO FRESH AIR; GIVE ARTIFICIAL RESPIRATION IF
BREATHING, HAS STOPPED,
INGESTION: CALL A PHYSICIAN IMMEDIATELY. ONLY INDUCE VOMITING AT THE
INSTRUCTIONS OF A PHYSICIAN. NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON,
REMOVE CONTAMINATED CLOTHING AND WASH BEFORE REUSE,
5, FIRE FIGHTING MEASURES
FLASH POINT (F).,,,,,,.,,: 85F (CC)
FLAMMABLE LIMITS LEL (X).: 1.00
FLAMMABLE LIMITS UEL (X),: 7.00
MSDS (CONTINUED) •° XX0055
PAGE 4 2
. E,XTINGUISHING MEDIA
FOAM, DRY CHEMICAL, CO2 ; WATER SPRAY TO COOL FIRE - EXPOSED
CONTAINERS,
FIRE FIGHTING PROCEDURES.:
WEAR SELF - CONTAINED BREATHING APPARATUS.
FIRE & EXPLOSION HAZARDS.:
VAPOR CAN TRAVEL DISTANCES TO IGNITION SOURCE AND FLASH BACK,
6, ACCIDENTAL RELEASE HEASURES
SPILL RESPONSE:
EVACUATE THE AREA OF ALL UNNECESSARY PERSONNEL,
WEAR SUITABLE PROTECTIVE EQUIPMENT LISTED UNDER EXPOSURE /
PERSONAL PROTECTION.
ELIMINATE ANY IGNITION SOURCES UNTIL THE AREA IS DETERMINED TO BE
FREE FROM EXPLOSION OR FIRE HAZARDS.
CONTAIN THE RELEASE AND ELIMINATE ITS SOURCE, IF THIS CAN BE DONE
WITHOUT RISK.
TAKE UP AND CONTAINERIZE FOR PROPER DISPOSAL AS DESCRIDED UNDER
DISPOSAL.
COMPLY WITH FEDERAL., STATE, AND LOCAL REGULATIONS ON REPORTING
RELEASES, REFER TO REGULATORY INFORMATION FOR REPORTABLE
QUANTITY AND OTHER REGULATORY DATA.
EM SCIENCE RECOMMENDS SPILL -X ABSORBENT AGENTS FOR VARIOUS TYPES
OF SPILLS. ADDITIONAL INFORMATION ON THE SPILL -X PRODUCTS CAN BE
PROVIDED THROUGH THE EM SCIENCE TECHNICAL SERVICE DEPARTMENT
(609) 354 -9200.
THE FOLLOWING EM SCIENCE SPILL. -X ABSORBENT IS RECOMMENDED FOR
THIS PRODUCT:
SX0863 SOLVENT Sr]L.L TREATMENT KIT
7, HANDLING AND STORAGE
HANDLING & STORAGE:
KEEP CONTAINER TIIGHTLY CLOSED.
STORE IN A COOL, WELL- VENTILATED AREA AWAY FROM IGNITION SOURCES
AND OXIDIZERS.
DO NOT BREATHE VAPOR.
DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING
NEVER USE WELDING OR CUTTING TORCH ON OR NEAR DRUM (EVEN EMPTY)
BECAUSE PRODUCT (OR RESIDUE) MAY IGNITE EXPLOSIVELY.
ELECTRICALLY GROUND ALL EQUIPMENT WHEN HANIII..]NG THIS PRODUCT.
RETAINED RESIDUE MAY MAKE EMPTY CONTAINERS HAZARDOUS; USE
CAUTION!
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
MSDS (CONTINUED) - XX0055 PAGE It 3
ENGINEERING CONTROLS AND PERSONAL PROTECTIVE EQUIPMENT:
VENTILATION! RESPIRATORY PROTECTION, PROTECTIVE CLOTHING, EYE PROTECTION
RESPIRATORY PROTECTION: IF WORKPLACE EXPOSURE LIMIT(S) OF PRODUCT
OR ANY COMPONENT IS EXCEEDED (SEE TLV /PEL), A NIOSH /MSHA APPROVED
AIR SUPPLIED RESPIRATOR ]S ADVISED IN ABSENCE OF PROPER
ENVIRONMENTAL CONTROL. OSIIA REGULATIONS ALSO PERMIT OTHER
NIOSH /MSHA RESPIRATORS (NEGAT]'VE PRESSURE TYPE) UNDER SPECIFIED
CONDITIONS (SEE YOUR SAFETY EQUIPMENT SUPPLIER), ENGINEERING
AND /OR ADMINISTRATIVE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE
EXPOSURE,
MATERIAL MUST BE HANDLED OR TRANSFERRED IN AN APPROVED FUME HOOD
OR WITH ADEQUATE VENTILATION
PROTECTIVE GLOVES (PVA, VITON OR EQUIVALENT) SHOULD BE WORN TO
PREVENT SKIN CONTACT.
SAFETY GLASSES WITH SIDE SHIELDS MUST BE WORN AT ALL TIMES.
WORK / HYGENIC PRACTICES:
WASH THOROUGHLY AFTER HANDLING.
DO NOT TAKE INTERNALLY,
EYE WASH AND SAFETY EQUIPMENT SHOULD BE READILY AVAILABLE,
EXPOSURE GUIDELINES
OSHA - PEL:
TWA STEL CL
• COMPONENT PPM • MG /M3 PPM MG /M3 PPM • MG /M3. SKIN
M- XYLENE
0- XYLENE
P- XYLENE
ETHYLBENZENE
ACGIH - TLV:
COMPONENT
100 435 150 655
100 435 150 655
100 435 150 655
100 435 125. 545
TWA STEL CL
PPM MG /M3 PPM MGYM3 PPM- MG /M3 SKIN
M- XYLENE.
0- XYLENE
P- XYLENE
ETHYLBENZENE
100 434 i 150 651
100 434 150 651
100 434 150 651
100 434 125 543
PHYSICAL AND CHEMICAL PROPERTIES
MSDS (CONTINUED) - XX0055 PAGE t 4
BOILING POINT (C 760 MMI•IG).: i38C
MELTING POINT (C) N/A
SPECIFIC GRAVITY (H20 = 1).; 0.872
VAPOR PRESSURE (MM HG).....: 5.1 20C
PERCENT VOLATILE BY VOL (X); 99 +X
VAPOR DENSITY (AIR = 1) • 3.6
EVAPORATION RATE (OUAC = 1): 0.61
SOLUBILITY IN WATER (X) 0,02X
APPEARANCE
COLORLESS LIQUID; AROMATIC ODOR
•
10. STABILITY AND REACTIVITY
STABILITY ' YES
HAZARDOUS POLYMERIZATION;
DOES NOT OCCUR
HAZARDOUS DECOMPOSITION,;
COX AND VARIOUS" HYDROCARBONS
CONDITIONS TO AVOID...,.;
HEAT, CONTACT WITH IGNITION SOURCE
MATERIALS TO AVOID
( ) WATER
( ) ACIDS
( ) BASES
( ) CORROSIVES
(X) OXIDIZERS
( ) OTHER :
11. TOXICOLOGICAL INFORMATION
TOXICITY DATA;
ORL -RAT LD50: 4300 MG /KG IHI_ -HMN TCL.O; 200 PPM
TOXICOLOGICAL FINDINGS:
TESTS ON LABORATORY ANIMALS INDICATE MATERIAL MAY PRODUCE ADVERSE
MUTAGENIC EFFECTS.
CITED IN REGISTRY OF TOXIC EFFECTS OF CHEMICAL SUBSTANCES .(RTECS)
12, DISPOSAL CONSIDERATIONS
EPA WASTE NUMBERS: 0001 U239
TREATMENT:
INCINERATION, FUELS BLENDING OR RECYCLE. CONTACT YOUR LOCAL
MSOS (CONTINUED) - XX0055 PAGE * 5
�~PERMITTED WASTE DISPOSAL SITE (TSD) FOR PERMISSIBLE TREATMENT
• SITES,
ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE
COMPLIANCE WITH ALL CURRENT LOCAL, STATE AND FEDERAL REGULATIONS.
113. TRANSPORT INFORMATION
DOT R SHIPPING NAME..,:
XYLENES
DOT ID NUMBER
UN1307
14. REGULATORY INFORMATION
. .�
TSCA . . . �.....
THIS PRODUCT IS A MIXTURE " . THE CAS NUMBERS OF ALL COMPONENTS •
ARE LISTED ON THE TSCA INVENTORY.
COMPONENT
M-XYLENE
O-XYLENE
P-XYLENE
ETHYLBENZENE
SARA
EHS -
(302)
SARA CERCLA
EHS`TPQ 'RQ
(LRS) (LBS)
1000
1000
100
1000
COMPUNENT`�
OSHA `� ` OSHA
-
,FLOOR LIST
..^^~`^'
O-XYLENE
P-XYLENE `-
ETHYLBENZENE
SARA � � DEMINIMIS
313 FOR SARA 313
(%),�
| .' �`�`'�` � �`.'� '� �/. ��� ' � ` '' . 1.0 -
`
Y, �.' ` �y � � ' 1.O
'� ' ' ' '�
'
Y �� '� Y � � � ` � 1.O
`
v . Y �� ` '` 1.0
:.15. OTHER INFORMATION ^ �
MqDS (CONTINUED) -`XX0O55� PAGE #6
titMMENTS:
NONE
NFPA HAZARD RATINGS:
HEALTH : 2
FLAMMABILITY : 3
REACTIVITY : 0
SPECIAL HAZARDS
REVISION HISTORY:
03/01/78 03/07/86 12/08/86. 06/09/87 10/27/87 08/25/88 03/01/91
07/15/91 09/08/95
1 = REVISED SECTION
N/A = NOT AVAILABLE
N/E = NONE ESTABLISHED
THE STATEMENTS CONTAINED HEREIN ARE OFFERED FOR INFORMATIONAL PURPOSES
ONLY ANO ARE RASED UPON TECHNICAL DATA THAT EM SCIENCE BELIEVES TO BE
ACCURATE, IT IS INTENDED FOR USE ONLY BY PERSONS HAVING THE NECESSARY
TECHNICAL SKILL AND AT THEIR OWN DESCRETION AND RISK. SINCE CONDITIONS
AND MANNER OF USE ARE OUTSIDE OUR CONTROL, WE MAKE NO WARRANTY, EXPRESS
OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE.
MSOS - XX0055 PAGE 4 7
"ISSUED DY VWR 07/09/98"
5- 0 tt
0
• 7
5
t
• DIA f7491.46,
; - 64(5461)
. _
/ "4 •
3-S-P-3E)10
VASE-. a'idV3V
IF
•
• •
XrflJc3 e;F-FIE/
0
It/ 14,61 iMTP
&Jae,' c-r-m EA-tow-T
1 F-Ar4
Ri-
FieF51-1 -5-upft_y
deG.F. pi F z92..
T;LiC.-7151) T1 w flH' 1-4
i
\:
t5r--17e3.1
•
to".6Repl-
----
1 ■■••••■•■•■nos.••••-•••••
-1,046.1F
Yiz1iLt.,hI •
• 4.
OVRFLaN/
Witsi cs-V1/4
Eviat
em4nev;i-Vist.
--1GoGe7 fad,
x0.
4:129-41, s---rt9Teklq
I7-2' z. •
//km A A t L 4 06 is 74 w
• •
REGISTERED JO" 7-7
2390
E
fII
BNCE
1171401(4-- Datitty:- 5,4-141
STATE GF 'oV.ASH;1GTON
PROJECT NAME : Primesource Corporation
PERMIT NUMBER : D98 - 0305
Telefon -Memo : With reference to the comments as a draft by the Public
Works Department, dated : September 17, 1998 1 had a
telefon- meeting with Ms. Joanna Spencer on : 10 /5 /98.
As to item (3 a : We are providing for the Flammable
Liquid Storage Room an Automatic AFFF - Water
Protection System and have the secondary containment
within the Storage Room with a capacity of approx.
1,324 cu.ft. As overflow are 2 x 8" pipes available, more
than necessary for liquids, but it is unknown, haw the
flowability of the foam-water mixture of the sprinkler
system will be, when activated.
The drainage-smile Is closed-in on three sides and open
towards West for rainwater to flow out. In case of an
emergency for the collection of the over -flow from the
Storage - Room, Sand bags will be placed for closure on
the West -End of the swole. The sand bags will be located
below the stairway of the emergency-exit at the Southest
corner of the building.
Before we designed the above system, we had a general
site -visit together with Chief Nick Olives of the Tukwila
Fire Dept.
Guenter Zimmer ( Engineering Consultant )
. -" DEC.16.1998 4:00PM
LANCE MUELLER
NO.269 P.2/2
• 2 Li AzY4544s . F0P
.�� -�-r
` ATTdA -t) -rev
• ._...a 1361=.K.1 N4a. C uy
Tr'r - wALl.., G -
lam. E.Ig5
L 41..J e -t..a.r As
Fa/ 1C9 pEc qb
12/14/98 08:22
2063627227
J.Simmons Constr
JOSEPH. S. SIMMONS CONSTRUCTION, INC.
FACSIMILE '/RANSi 77A1,
1)A'FE: 12 -14 -98
TO: City of Tukwila
A'1-1'N.: Dave Larson
J013: Prime Source; <.:D98 =0306 `.
TOTAL PAGES SENT: G?,
INC. THIS PAGE
FAX 1/ 206- 431 -3665 PHONE
FROM: DANJE1, MUI.VIHI1.1.
WE ARE S1:NNI)1NG:
1) copy of Inspection Record dated 12.9 -98
P.01
"E1VED
CFI, 1 4 1998
E::' ;v MUN1TY'
OPMENT
COMMENTS:
NTS:
We are proposing to cover the insulation with FSK paper. 1.)o the joints have to be taped.
Please call me at 206 -362 -7227.
DANIEL MULVIHILL
3223 Nf. 125TIi STithkT P.U. 110X 27089 SJ'sAT'I'I.R. WA 98125
P11ONF: 206.362. 722.7 ) AX: 206.362-0118 JOSEPSS )53 J
12/14/98 08:23
• . . .•, . •
a 2063627227
. •
• • .•. ••
;ant by: VOIR SCIENTIFIC SEATTLE • 206 575 4064;
NNO.
CITY OF TUKWILA BUILDINCt DIVISION
6300 Southcanier Blvd., #100, Tukwila, WA 98188 (206) 1131-3670
• .
J.Sirimons Constr P.02
• ( •
•
4.19• 8
9: 29AM; )91606ei pagi11
.
12/14198
INSPECTION' RECORD
Retain a copy With permit
Project:
r;IA-12 Stir
Address:
Special lnarUctions:
1 Approved per applicable codes.
COMMENTS:
.--1...
Type 01 insrele_eCtir)k Cyy
Date called: .0 f
....
Dale wanted:O.;
Requester:
Corrections requited prior to approval.
s.ez-iv22-xn.
_ -(
• ..... •••
. . .
!Inspector: 441 j
S42,00 RE114SPOCTIO FEE REQUIliED. Prior to Inspection. fee must
paid at 6300 Southconter Diva, Suite 100. Cell to schedule rolapection.
I Date:
Receipt Nc.:
TO:
FROM:
DATE:
SUBJECT:
City of Tukwila
Department of Public Works
NOTIFICATION OF UTILITY PERMIT ACTION
Permit Center
Public Works Engineering
OCTogge. 14 ,1998
Prime Source
355 Treck Drive
Permit Number: D98 -0306
Contact Person: Joe Simmons /Dan Mulvihill
Phone: (206) 362 -7227
John W. Rants, Mayor
Ross A. Earnst, P. E., Director
THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE
IN ACCORDANCE WITH THE PLANS APPROVED ON . OcroSER t ., 1998:
5TORM O2fMNA6,E
PERMIT FEE
2.5.00
TOTAL: $25.00
Two copies of the confirmed Utility Permit Application and plans are attached for inclusion in the
permit file.
JJS /tkf
CF: Development File (with copy of application and plans)
PW Utilities Inspector (with copy of application and plans)
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433 -0179 • Fax (206) 4313665
t .
October 7, 1998
Brenda Holt
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, WA 98188
Re: Correction Letter #1, Permit #D98 -0306
Dear Ms. Holt,
'JOSEPH S.
SIMMONS
CONSTRUCTION NC.
In The City of Tukwila Department of Public Works Comments dated 9- 17 -98, there are
three items listed that need to be addressed. They are as follows:
1) The fire sprinkler system single check valve should be changed to a double check
valve. Primesource has contracted with Patriot Fire Protection Inc. to complete this
work. Patriot Fire will obtain their own permit for this work. The contact there is Mark
Fromong, his phone number is 253- 926 -2290.
2) The Business Declaration form is completed and attached.
3) Please see the attached letter from Guenter Zimmer dated 10 -7 -98, this letter addresses
most of the issues of item #3. Also attached is a section of the drainage swale drawn by
Lance Mueller and dated 10 -7 -98.
I believe we have addressed all of your concerns. Please call if you have any questions.
Sincerely yours,
fAL,A,4-4.:(7
Daniel Mulvihill
3223 NE 125TH STREE
A 0. BOX 27089
SEATTLE, WA 98125
(206) 362 -7227
FAX (206) 362 -0118
JOSEPSS 153 JD
RECEIVED
CITY OF TUKWILA
OCT p 8 1998
PERMIT CENTER
ooreoroo
•
✓EP 21
7CL•L S o t t o r�: j =00 o r.o 107.0
09/29/9e 141
'98 03 :23Pt"1 7LIJ IJ1Lk ric•rrr:•:
rnincaoL•ncc
zo6se2�zz�
anon,
,.(— t. bimmon5 Lori Lr
Business Declaration
P,?
r. o� i7oot
Part 1
Fill out this form, fold it so the business -reply portion is showing and return if to Metro's industrial
Waste section, 11. you need to use additional sheets of paper, please mail the entire package of information
in a separate envelope. Mail to: Metro, Water Pollution Control Department, Industrial blasts Section, 130
Nickerson Street, Suite 200, Seattle, WA 98109 -1658.
Company nasrtet
Contact person at your company;
Title; Vice, £stde'n,t
Telephone; b . 3c q_ss -) 2
Mailing address: 35S -1 . ?1 Ills
Type of business (Whet does your firm :manufacture or produce?): bisgn);v h0\ 0d P rtylfit.
Nvsnber of business sites: J Sfyjje
Address of each busine s cite No. of c:ployees at site:
LcialLg
•••_._ _._.■._
z,_
"'`e additional sheets if necessary.
•
Part 11
Please circle the correct answer as it applies to the business site given below. If you have tiore'thar► one
business site,please copy this page and fill out a forte: for etch site,
Company name:, PilArrie:60/1/1.re
Site address; 35.E I r -c- . Or-We
Contact person: t %nGi,aW t
Title: V i Ce A „ _,-i ..L L/
nlephone:cOD6› 3q 1t--5S Z
Does your cowpony use water for cooling, production, manufacturing, washing, rinsing or
cleaning floors in prod Lion areas?
Cl Yes (.1J No
2. Does your buiidirig have floor drains, catch basins, sumps or sinks Ln production areas or any
other out to the sanitary sewers?
Yea CD No wE kciAQ > a
IA* pretkidc t/02- lAfrdit:b4 64/ 61'. ffri/er
kWh- 0(7C .2u4_ .
voe-cot-oo
'r�•a iv. oo rni coo or- ioro
qy /ZVeyd ( '4L
rnx rstovL nca
$ LCbJbLfLLf
5EP E1 's5 03 :1EPII TUKNILR DCD'PN
S. Does your business store or mix liquid chemicals?
Ye'
k' fn No
ey for resale?
Yes 0 No
4. 'Does your company use solvents or flammable substances?
Yes No
If yes, do you recycle them?
CI Yes C1NI()
5, Toes your company process food or anima) matter?
0 Yes No
6. Does your company use metals or metal solution; in manufacturing, processing, treating
waste, etc.7
Yes ,' LI No
?, Does yot3r'cohpany pump or 'discharge groundwater for constnittior dewatering or
groundwater remedi /ation7
tYes rt No
8. Does your company have uncovered storage areas or outdoor activities, such as vehicle
rriaintenance,equiprne asking and drrm•rieAnSng?
Dn000
4- ,. 31'1nof1s LOn!tt•
® Yea ...f�
4
9. How may gallons 01 industrial wastewater dots your company discharge each day?
(check one
None
Less than 5,000 gallons
0 5,000 - 25,000 gallops
i� More than 25,000 gallons Thank you
S u S I CHESS REPLY MAI L
FIRST C{ASSI pERldeT No, fosse sEATTL{i• WA
PC8TAOC WILL an PAID by ADOIMEBdgE
r. of q23 OOO
oliednETplo
INDUSTRIAL WASTE SECTION
WATER POLLUTION CONTROL DEPARTMENT
KING COUNTY DEPARTMENT OF METROPOLITAN SERVICES
MS IHW
821 2N0 AVE
SE/ TT a WA 98104.995C
( l�l��l��l�l, Ililticl1l ►t1111�1111��11�1�111 111
NO POMOE
NECESSARY
IF MAILED
IN TN8
UNITED CUT'S
liniamonom
MIKISISINIMMINt
r
D
9 -25-98 BCM
ATLANTA/East
3905 Steve Reynolds Blvd. Ste. 100
Norcross, GA 30093
Tel: (770)279 -8900; 800 - 992 -4897
Fax: (770)279 -9852
Gary Kirchner, Branch Manager
Ed Winnicki, Office Manager
Bob Forrest, GM Systems, East
Bob's pager 800 - 307 -6068
Bob's car 404- 680 -0691
BIRMINGHAM /East
124 Citation Court
Birmingham, AL 35209
Tel: 800 - 733 -8216; (205)942 -3181
Fax: (205)941 -1048
Cliff Grinnell, Branch Manager
Nell Smith, Operations Manager
Fred Kilgooe, Environ. Manager
Janelle Thomas, Accounting
Jack I'rugh, Regional VP
Jack's fax (205)942 -9295
Jack's voicemail 800 -827 -8973 ext. 132
BOSTON /East
80 Research Road
Hingham, MA 02043
Tel: 800 -654 -6016; (781)740 -4422
Fax: (781)740- 0433/0434
John Fitzwater, Branch Manager
John's pager 888 - 691 -9632
CIIICAGO /East
700 District Drive
Itasca, IL 60143
Tel: 800 - 621 -1049; (630)875-2200
Fax: (630)875 -2222
Systems Tel: 800 - 211 -1734
Mark Gianneschi, Branch Manager - 2295
Arnie Cogan, VP National Sales-2220
Dan Lehman, Credit — 2276
Joel Esparta, -2239, Joel's fax - 2240
Mike Fox, GM Systems, Central - 2295
Mike Fox Voicemail: 800-224-3430 x295
1j:corpor re records:psclocations
PR1MESOURCE CORPORATION
Branches/Divisions
CINCINNATI/East Headquarters
1650 Magnolia Drive
Cincinnati, 011 45215
TcI: (513)563 -6700
Fax: (513)563 -0377
Ray Rafalowski, Branch Manager
Pam Robinson - Helton, Office Manager
Jim Purcell, VP & GM - East
Jim's voicemail (513)881 -0416
Jim's fax (513)563 -4859
Karen Krum!, Director Bus. Support -East
DALLAS /Central
3304 Manor Way
Dallas, '1'X 75235
Tel: (214)358 -1456
Night: (214)358 -1459
Fax: (214)351 -1756 & 358 -0840
Dave Friedholm, Branch Manager
Dave's pager (214)359 -1500
Dave's car (214)616 -2931
Kevin Nation, Office Manager
DENVER/West
4100 Jackson Street
Denver, CO 80216
Tel: (303)321 -0460
Fax: (303)321 -1417
Gene Kandt, Branch Manager
Doug Nickel, Customer Service
DES MOINES /Central
1513 SE Cortina Drive
Ankeny, IA 50021
Tel: 800- 767 -8421; (515)964-5706
Fax: (515)964 -0198
Ed Stewart, Branch Manager
Marlene McClintock, Office Manager
DES MOINES /Central
10730 Rickman Road
Des Moines, IA 50325
Tel: (515)270 -8090
Fax: (515)27016989
Jerry Parker, Brancli Manager
HOUSTON/Central .
3.48 Garden Oaks Blvd.
Houston, TX 77018
Tel: (713)699 -5959 or 0323
Fax: (713)699 -9916
Dave Friedholm, Branch Manager
Brenda Redman, Office Manager
llOUSTON /Central
1303 N. First Street
Bellaire, TX 77401
Tel: (713)664 -5678
Fax: (713)661 -9145
Jordan Fischman, Branch Manager
Sherri Griffin, Customer Service
JACKSON /East
199 Interstate Drive, Suite N
Richland, MS 39218
Tel: 800 - 488 -6429; (601)932 -3847
Fax: (601)932 -2571
David Winnett, Branch Manager
James Thurman, Office Manager
KALAMAZOO /East
3700 E. Kilgore Road
Kalamazoo, MI 49002
Tel: 800-632-7832;(616)381-2640
Fax: (616)381 -9428
Dan Schultz, Branch Manager
Mike Miles, Operations Manager
KANSAS CITY /Central
1146 Booth
Kansas City, KS 66103
Tel: (913)342 -1234
Fax: (913)342 -1222
Pat Fairley, Branch Manager/VP
Kim Robinson, Customer Service
LANCASTER/East
123 W. Airport Road
Lititz, PA 17543
Tel: 800 - 457 -8356; (717)569 -4581
Fax: (717)569 -5749
Andy Brubaker, Branch Manager
Donna Meikrantz, Office Manager
Bonnie Frommeyer, 800 - 779 -4650
Mike Borne, Dir. Pressroom Products
(717)569 -7311
Mike's fax: (717)569 -7312
Mike's address: Suite 211
1821 Oregon Pike
Lancaster, PA 17601
LAS VEGAS/West
3620 W. Reno, Unit
Las Vegas, NV 89118
Tel: (702)384 -9988
Fax: (702)739 -9030
Phil Trifunac, Branch Manager
Vicki Elliott, Customer Service
SE LOS ANGELES/West
16870 Valley View Avenue
La Mirada, CA 90638
Tel: 800 -753 -9500
Fax: (714)739 -7909
LOS ANGELES/West
4425 Sheila Street
I.os Angeles, CA 90023
Tel: 800 -879 -2355; (213)268 -9500
Fax: (2I3)268 -2370
Larry Roghair, Branch Manager
Kim Zeigler, Operations Administrator
Jim Stoker, GM Los Angeles
LOS ANGELES/West
13430 Alondra Blvd.
Cerritos, CA 90703
Tel: 800-634-5041; (562)802-1866
Fax: (562)404 -2781
Dan Freedland, Branch Manager
Tom Horan, Digital l'rinting
'T'om's car (805)338 -7783
MIAMI/East
3991 Commerce Parkway
Miramar, FL 33025
Tel: (305)625 -4488 (Dade)
(954)431 -1000 (Broward)
Fax: (954)435 -5206
Greg Furlong, Branch Manager
Linda Grogan, Office Manager
Greg's car (954)980 -4178
MILWAUKEE/East
2236 So. 162nd Street Mail must go to
New Berlin, WI 53151 P.O. Box 510891
Tel: 800-597-8421; (414)796-1250
Fax: (414)796 -2921
John Solwold, Branch Manager
John's car (414)313 -9531
John's voicemail 800 -224 -3430 ext. 265
Tom Roemke, Assoc. Branch Manager
Vickie Alioto, Customer Service
0
D
D
D
D
0
D
c
a
u
D
D
r.
D
a•
9 -25-98 BCM
4 MINNEAPOLIS /Central Headquarters
;1395 Commerce
Mendota Ileights, MN 55120
Tel: (612)452 -9320; 800 - 758 -8421
Fax: (612)688 -1439
Ted Padley, VP & GM — Central -1400
Ted & Rick's fax (612)688 -1424
Rick Guy, Dir. Bus. Support, Central
(612) 688-1402
Jim Menne, VP Sales 688 -1429
Jim Manna's car (612) 750-7912
Tom Murray, Operations Manager
(Printed Circuit & Service Dept.)
2822 So. Anthony Lane
Minneapolis, MN 55418
Tel: (612)781 -4874
Fax: (612)782-2702; (612)788-1920
John Carnahan, VP, ext. 712
MOBILE/Fast
5252 Halls Mill Road 131dg. 2 -A
Mobile, AL 36619
1e1: 800- 755 -6560; (334)666 -8070
Fax: (334)666 -8085
Greg Kennedy, Branch Manager
Melissa Schleigh, Office Manager
NASHVILLFJEast
1878 Air Lane Drive
Nashville, TN 37210
Tel: (615)885 -7777
Fax: (615)883 -5853
Paul Clinton, Branch Manager
Paul's pager (615)780 -6662
Earl Snider, Office Manager
NEW ORLEANS/East
5717 Salmen Street
llarahan,LA 70123
Tel: 800-452-7214; (504)733-4181
Fax: (504)733 -4186
Randy Osmon, Branch Manager
Randy's pager 800 - 999 -6710, #9990806
Randy's voicemail 800- 827 -8973, 11180
Gayle Lorio, Operations Manager
lj:corpr ;.,, records:psdocations
• �L:
PRIMESOURCE CORPORATION
Branches/Divisions
OMAHA /Central
14920 Grover Street
Omaha, NE 68144
Tel: (402)697 -9013
Fax: (402)697 -4999
Bob Bloemer, Branch Manager
Dick Weithoner, Operations Manager
OMAHA /Central
4110 8. 52nd Street
Omaha, NE 68117
Tel: (402)731 -5252
Fax: (402)731 -8558
Jerry Vogel, Branch Manager
Mark Perkins, Customer Service
ORLANDO /East
3800 Commerce Loop
Orlando, FL 32808
Tel: (407)290 -5723
Fax: (407)290 -3447
13;11 Langston, Branch Manager
Ellen Watko, Office Manager
I' I I ILADELPI l I A /East
15 Twinbridge Drive
Pennsauken, NJ 08110
'1'd: (609)488 -7200; 800- 726 -2642
Fax: (609)488 -7255
John McDevitt, Branch Manager — 7213
John's pager (610)303 -5866
John's home fax (610)259 -7634
Mike Quaranta, 011ice Manager
Bob Kurclic, Regional Saks Manager
Mike Silverman (609)488 -7206
PIIOENIX/West
3321 E. Atlanta Avenue
Phoenix, AZ 85040
Tel: (602)243 -9191
Fax: (602)268 -6015
Caul Stevens, Brandh Manager
Thad Ryan, Operations Manager
PITTSBURGII /East
1020 Alcon Street
Pittsburgh, PA 15220
Tel: (412)922 -1333
Fax: (412)922 -0510
Bill Brindle, Branch Manager
Karen Stoddart, Office Manager
PO1U'LAND/West
5410 S.E. International Way
Portland, OR 97222
Tel: 800- 452 -8756 (503)653 -8300
Fax: (503)653 -0953
John Vanderkin, Branch Manager
Cindy Comctt, Operations Manager
PORTLAND/West
26100 SW 95111 Ave. Suite 200
Wilsonville, OR 97070
Tel: (503)570 -0500
Fax: (503)685-9588
John Vandcrkin, Branch Manager
'Pony Boynton, Operations Manager
SACRAMENTO/West
1700 Enterprise Blvd., Suite D
West Sacramento, CA 95689
Tel: (916)371 -1100
Fax: (916)371 -2438
Jim Tracey, Branch Manager
flobbii Wright, Operations Manager
ST. LOUIS /Central
1919 S. Broadway
St. Louis, MO 63104
Tel: (314)231-9770; 800-899-8897
Fax: (314)231 -9774•
Chaz Chastain, Branch Manager
Sean Parker, Customer Service
SAN DIECO/West
6160 Marindustry Drive
San Diego, CA 92121
Tel: (619)452 -6115
Fax: (619)452 -6636
Carl Stevens, Branch Manager
Thad Ryan, Operations Manager
SAN FRANCISCOA'Vest
342 Ilarbor Way
So. San Francisco, CA 94080
Tel: (650)875 -3888
Fax: (650)873 -0291
Mark Harley, Branch Manager
& GM Systems, West
Mark's car (510)914 -0456
Mark's voice mail (650)253 -0757
Mike Calegari, Customer Service
SAN FRANCISCO/West
2955 3rd Street
San Francisco, CA 94107
Td: (415)647 -807I
Fax: (415)282 -4109
Sales office.
SAN JOSE/West
615 Dado Street
San Jose, CA 95131
't'eI: (408)435 -1901
Fax: (408)435 -2724
Jim Tracey, Branch Manager
Cindy Parmiter, Customer Service
Paul Heine, Regional VP
SEATTLE/West
1226 37111 Street NW, Suite A
Auburn, WA 98001
Tel: (253)833 -2733
Fax: (253)833 -4473
Ron Wilson, Branch Manager
D
D
D
9 -25-98 BCM
,SEATTLE/West Headquarters
'355 Treck Drive
Seattle, WA 98188
Tel: (206)575 -9494
Fax: (206)575 -1370
Ron Wilson, Branch Manager
Elaine Woodrow, Operations Manager
John Goddard, Exec VP & GM - West
Gerry Cooper, Dir. Bus. Support -West
Allan Feeney, Dir. Business Systems
Barry Maulding, VP & General Counsel
Bob Miller, Treasurer
Steve Greenstein, Systems, 601 -0949
ST. PAULICentral
2446 University
St. Paul, MN 55114
Tel: (612)645 -9301
Fax: (612)645 -1602
Bob Johnson, Branch Manager
Kathy Skrce, Customer Service
D
D
l
D
u
1
D
D
1j: records:psclocations
PRIMESOURCE CORPORATION
Branches/Divisions
CM GRAPHICS — Headquarters
112 Iladdontowne Court, Suite 204
Cherry Hill, NJ 08034
Tel: (609)795 -2100
Fax: (609)795 -6411
Frank Matteo, Vice President & GM
Frank's car (609)634 -4786
Chris's car (609)458 -8928
PRIMESOURCE CORPORATION
Corporate Headquarters
4350 Haddonfield Road, Suite 222
Pennsauken, NJ 08109
Tel: (609)488 -4888
Fax: (609)486 -2999
Jim Mullan, President & CEO
13111 DeMarco, VP & CFO
Fred Heinkel, Sr., VP Sales & Marketing
Sue McBride, Dir. Corporate Accounting
Joel Saftlas, Dir. Procurement & Ali'
Al Skalisky, Dir. Human Resources
Howard Wilson, Dir. Administration
PROJECT MAIN/1E : Primesource Corporation
PERMIT TIMBER : D9B - 0306
Telefon -Memo : With reference to the comments as a draft by the Public
Works Department, dated : September 17, 1993 i had a
telefon- meeting with Ms. Joanna Spencer on : 10 /5 /98.
As to item (3, : We are providing for the Flammable
Liquid Storage Room an Automatic AFFF - Water
Protection System and have the secondary containment
within the Storage Room with a capacity of approx.
1,324 cu.ft. As overflow are 2 x 5" pipes mailable, more
than necessary for liquids, but it is unknown, how the
flowability of the foam -water mixture of the sprinkler
system will be, when activated.
The drainage -swale Is closed -ire on three sides and open
towards West for rainwater to flow out. In case of an
emergency for the collection of the over -flow from the
Storage -Room, Sand bags will be placed for closure on
the West -End of the swale. The send bags will be located
below the stairway of the ernergency --exit at the Southest
corner of the building.
Before we designed the above system, we had a general
site -visit together with Chief Nick Olives of the Tukwila
Fire Dept.
Guenter Zimmer ( Engineering Consultant )
YA.a. ps..vrt46:
eAtRileral 604100
Fevicli4o
iXISflG ,r--9i/.
.•■••••••• •■■■.. roam. ...M....
0'
laVacvie.-1-TY1 .9410415T
FgF9-1 6-uppL.y
dt9r zaz.
I 1- 1g
Att
•rve-1122.1 _--`1"
p‘t-PHALri- .-.1EE2F LOW
W-1
1.•
—.•
-VAL) -t.o.,64.s
ytar. . •
• •
PAKact-- 9TAN1
II= f
KI -
//kW Mdstikuit-4 Mra-/.4t2A
23O
REGISTERED
vIl
rt it NCE JaLER
STATE GF WASH:NGTON
tt'')elAAXT., Ne' tr‘ Atity4Tr%
•C.11 E
City of Tukwila
John W. Rants, Mayor
Department of Community Development Steve Lancaster, Director
October 6, 1998
Joe Simmons
3223 NE 125th
Seattle, WA 98125
Dear Mr. Simmons:
SUBIECT: CORRECTION LETTER #1
Development Permit Application Number D98 -0306
PrimeSource Corporation
355 Treck Drive
This letter is to inform you of corrections that must be addressed before your application for
development permit can be approved. All correction requests from each department must be
addressed at the same time and reflected on your drawings. I have enclosed review comments
from the Public Works Department. At this time the Building Division, Fire Department and
Planning Division have no comments regarding your application for permit.
The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate
revision block. If your review does not require revised plans but requires additional reports or
other documentation, please submit four (4) copies of each document.
In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I
have enclosed one for your convenience. Corrections /revisions must be made in person and will
not be accepted through the mail or by a messenger service.
If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431-
3671.
Sincerely,
Brenda Holt
Permit Technician
Enclosures
File: D98 -0306
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665
City of Tukwila
Department of Public Works
John W. Rants, Mayor
PUBLIC WORKS D F.2 A R M E L COMMENTS
Ross A. Earnst, P. E., Director
DATE: September 17, 1998
PROJECT NAME: Primesource Corporation
PERMIT NUMBER: D98 -0306
PLAN REVIEWER: Contact Joanna Spencer at (206) 433 -0179 if you have any questions
regarding the following comments.
1. The existing single check valve inside the fire vault shall be replaced with a State Dept. of
Health approved detector double check valve assembly. The existing fire vault is located west
of the driveway in the landscaped area. (Public Works detail enclosed). Please contact Chief
Nick Olivas at (206) 433 -1859, Tukwila Fire Dept., regarding any other requirements or
calculations for DDCVA replacement. The plan shall be prepared by a Washington State
licensed Fire Prevention Designer.
2. Please fill out the attached Business Declaration Form.
3. Please explain the function of the two 8" metal pipe overflows, quantify possible overflow,
show cross - section of proposed asphalt overflow drainage swale. Please show how flows from
the swale will be conveyed to the existing storm drainage system.
uQ4-e. Itit4 -t9-� �u— e e�� eat P L,io . c. (.v cic-s
7� R
I's c t.t s 5 .
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433 -0179 • Fax (206) 431-3665
PLAN SLIP
ACTIVITY NUMBER: D98 -0306 DATE: 10 -8 -98
PROJECT. NAME: PRIMESOURCE`CORPORATION
Original Plan Submittal Response to ,Incomplete Letter
XX Response to Correction Letter .#
Revision �# After: Permit Is Issued
DEPARTMENTS:
Buie Division
P blic Works SI&
5/0
Fire Prevention
MA, !, G1'lq-4y
Structural
n
Planning Division '®
t1/or
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 10 -13 -98
Complete Incomplete n Not Applicable
Comments:
1 1
TUES /THURS ROUTING:
Please Route n No further Review Required
Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra)
REVIEWERS INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days)
Approved
Approved with Conditions
REVIEWERS INITIALS:
DUE DATE: 11 -10 -98
Not Approved (attach comments) n
DATE:
CORRECTION DETERMINATION:
Approved
DUE DATE:
Approved with Conditions Not Approved (attach comments) n
REVIEWERS INITIALS: DATE:
\PR- ROUTE.DOC
6/98
?emit d PLAN REV W /ROUTIN SLIP
ACTIVITY NUMBER: D98 -0306 DATE: 9 -9 -98
PROJECT NAME: PRIMESOURCE CORPORATION
XX Original Plan Submittal Response to Incomplete Letter
Response to Correction Letter #
Revision # After Permit Is Issued
DEPARTMENTS:
B iid'n Divisio
ublic Works
Fire I-'rvention
1 .-ae
Structural � l�
P1 anrt Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues, Thurs)
Complete
DUE DATE: 9 -10 -98
Incomplete Not Applicable n
Comments:
TUES /THURS ROUTING:
Please Route n No further Review Required
Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra)
REVIEWERS INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 10 -8 -98
Approved n Approved with Conditions El Not Approved (attach comments)
e' bvve ovl 1 • maii J em.
REVIEWERS INITIALS: DATE:
PtJ
CORRECTION DETERMINATION:
Approved
DUE DATE:
Approved with Conditions E Not Approved (attach comments)
REVIEWERS INITIALS:
DATE:
\PR•ROUTE.DOC
6/98
CITY OF TUKWILA
Department of Community Development
Building Division - Permit Center
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431 -3670
DATE: /0` (9 79 PLAN CHECK/PERMIT NUMBER:
PROJECT NAME: me. .u/
PROJECT ADDRESS:
CONTACT PERSON: ra1 %ifcc k, •
PHONE: ,; .OLo- 3 C-;4-- 7ZZ 7-
REVISION SUMMARY: Hfr .),\ -3`iC. V 10 -s \ - ?v -er
c1c7.c- ct -17- ( 9
CKw\ u,r s 1 ‘1,:1.v--cc, v 'Che \r-e 43Y\r\1sc■-er EyS'�-em w■ \1
\-\04\c -we by fig _ o\Nrvec Mkt- C:v.cet c\-o (At\��r
‘:? i..,• 31! \0 \T- t LYN ' \(SCOA 5 \a \V x7_ \<_
`,V\ (A- �1�� Cd -t. Y- \ avvf `� C�CG;;v�C�c SI�.tCt� \'�_.
•
•
SHEET NUMBER(S)
"Cloud" or highlight all areas of revisions and date revisions. C@1VED
CVr( OF TUKV`111A
SUBMITTED TO: wog cegreR
sioed Ua
• Plannin
llc�}Vi%orks
3/19/96
City of Tukwila
Fire Department
Fire Department Review
Control #D98-0306
(510)
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
September 29, 1998
Re: Prime Source Corporation - 355 Treck Drive
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3 -1.1)
2. One or more portable fire extinguishers having a
rating of not less than 20 -B shall be located not less than
10 feet (3048 mm) or more than 50 feet (15240 mm) from any
Class I or II liquid storage area located outside of a
liquid storage room. (UFC 7902.5.11.5.2)
Portable fire extinguishers shall be securely
installed on the hanger or in the bracket supplied,
placed in cabinets or wall recesses. The hanger or
bracket shall be securely and properly anchored to the
mounting surface in accordance with the manufacturer's
instructions. The extinguisher shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor and the clearance between the
bottom of the extinguisher and the floor shall not be
less than 4 inches.
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 575-4439
City of Tukwila
Fire Department
Page number 2
John W. Rants, Mayor
Thomas P. Keefe, Fin; Chief
(NFPA 10, 1 -6.3) (UFC Standard 10 -1)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1 -6.5)
Fire extinguishers require monthly and yearly
inspections. They must have a tag or label securely
attached that indicates the month and year that the
inspection was performed and shall identify the
company or person performing the service. (NFPA 10,
4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and
halon type fire extinguishers shall be emptied and
subjected to the applicable recharge procedures.
(NFPA 10, 4 -4.1) If the required monthly and yearly
inspections of the fire extinguisher(s) are not
accomplished or the inspection tag is not completed, a
reputable fire extinguisher service company will be
required to conduct these required surveys. (NFPA 10,
4 -3, 4 -4)
3. No point in a sprinklered building may be more than
250 feet from an exit, measured along the path of travel.
(UBC 1004.2.5.2.2)
Exit doors shall swing in the direction of exit travel,
when serving any hazardous area or when serving an
occupant load of 50 or more. (UBC 1003.3.1.5)
Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort.
Exit doors shall not be locked, chained, bolted,
barred, latched or otherwise rendered unusable. All
locking devices shall be of an approved type. (UFC
1207.3)
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space. (UFC 1207.3)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
Fire Department
Page number 3
John W Rants, Mayor
Thomas P. Keefe, Fire Chief
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 1207 -1212)
When two or more exits from a story are required, exit
signs shall be installed at the required exits and
where otherwise necessary to clearly indicate the
direction of egress. (UBC 1003.2.8.2)
Exits shall not pass through kitchens, storerooms,
restrooms, closets or spaces used for similar
purposes. (UBC 1004.2.2)
4. Maintain sprinkler coverage per N.F.P.A. 13.
Addition /relocation of walls, closets or partitions may
require relocating and /or adding sprinkler heads.
All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation
or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than
50 heads shall have the written approval of the
W.S.R.B., Factory Mutual, Industrial Risk Insurers,
Kemper or any other representative designated and /or
recognized by The City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler ,
work shall commence without approved drawings. (City
Ordinance #1742)
Contact The Tukwila Fire Prevention Bureau to witness
all required inspections and tests. (UFC 10.503)
(City Ordinance #1742)
Fire sprinkler density shall comply with 1997 U.F.C.
article 79, for flammable liquid storage room.
5. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
6. "No Smoking" signs shall be conspicuously posted
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
Page number 4
within and at all entrances to hazardous materials storage
areas.
7. Only non - sparking tools shall be used in hazardous
areas where the presence of a spark could result in an
explosion or fire.
8. Satisfactory provisions shall be made for containing
or neutralizing spills or leakage of hazardous materials.
(UFC 8001.5.2.3)
9. Hazardous materials shall not be released into a
sewer, storm drain, ditch, drainage canal, lake, river or
tidal waterway, or upon the ground, sidewalk, street,
highway or into the atmosphere. (UFC 8001.5.1)
10. Fire doors, fire windows and fire dampers shall have
a label or other identification showing the fire protection
rating. Such label shall be approved and shall be
permanently affixed. (UBC 713.3)
11. There shall be no enclosed usable space under
stairways in an exit enclosure, nor shall the open space
under such stairways be used for any purpose. (UFC 1210.3)
12. Your street address must be conspicuously posted on
the building and shall be plainly visible and legible from
the street. (UFC 901.4.4)
13. Accumulation of combustible waste material is
prohibited during the demolition phase of this project.
Remove and properly dispose of all waste material prior to
the close of the working day and as often throughout the
day as needed.
14. "NO SMOKING" areas shall be designated in warehouses,
stores, industrial plants, institutions, schools, places of
assembly or where combustible materials are stored or
handled, when conditions are such as to make smoking a
hazard. Please post the following area(s) with no smoking
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439
City of Tukwila
Fire Department
Page number 5
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
signs with lettering, size, and location to be clearly
visible from adjacent areas. (UFC 1109.4.1) (in warehouse)
Smoking is not allowed in designated "NO SMOKING"
areas. Please assure that the area is posted and
implement a company policy for enforcement of this
requirement. (UFC 1109.4)
15. A permit is required for the use, storage, handling
or sale of flammable or combustible liquids. (UFC 105.8 -
F.3, article 79)
A permit application is enclosed for your convenience.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
516
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57$4404 • Fax (206) 57$4439
DEPARTMENT OF LABOR AND INr STRIES
'REGISTERED AS PROVIDED BY LAW AS
'CONST CONT GENERAL
,.::,•_, . -,, REG I ST .• # .. , . ,, . ; EXP` , ::DATE
'.CCO1 JOSEPSS153JDI04/04/1999
EFFECTIVE; ;DATE.*: :_;::; ;.,:04/04/1985 r
JOSEPH S SIMMONS CONST INC.
PO BOX 27089
SEATTLE WA 98125
F62.M52.00O (S /97)
Detach And Display Certificate
1REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST. # EXP. DATE
CCO1 JOSEPSS153JD 04/04/1999
EFFECTIVE DATE 04/04/1985
JOSEPH S SIMMONS CONST INC
PO BOX 27089 '
SEATTLE WA 98125
Signature
Issued by DEPARTMENT OF LABOR AND INDUSTRIES
Please Remove
And Sign
Identification
Card Before
Placing In
Billfold
NSW ffitgaVr
LeNG
O H�
&K15
•
M
NEU✓
- li./tA1%LF
STOp2p rrc
iize94 /NR SdPRY
rtpp - ry WITrVn1 12•
14a."r ti'L2n411>a
s lfM CfrFtaysT
E SC Iv 1 I k f /WA en-I $UI LF7E 1
1 I I
I ? I 1
Wei c8PFI
e . Rf
G M. ZZ
wwean fps
FILE COPY
understand that the Plan Check appr
suclact toerrorsandomissionsandapProva
plans does not authorize the
adopted code or ordinance. Rece of
ttatIOP sCOPV Oi appr0"edplan
1MIC
Parts
iaXf llNG ?f"KKI
J
WSW
EXIS iI .CO
ARGP.
•
I T P lip. N
SEPARATE PERMIT
REOUIREO FOR:
^� 0 1CAL
ECTRICAL
PLUM8ING
❑ GAS PIPING
CITY OF T.11O° -A
F:UILDIPIG 1'01`•'! =IO''I
pv9yiu�.
pCl 19 ryaa
1"
Thu portion of Lot 4, Andover Industrial Park No. 5,.as recorded
in :'came 83 of Plats, Pages 22 and 23, Records of King County,
Was;ington, described as follows: •
Beginning at a point on the south line of said Lot 4, which is
North 88 12'32" west of the southeast corner of Lot 4,a distance
of 86.17 feet; thence north 88 12'32" west 387.73 feet to the
sorthwest corner of said Lot 4; thence north O1 47'28" east along
the west line of Lot 4, a distance of 124.79 feet; thence coetin- -
wing along said west line along a curve to the right having a radius
of 110.28 feet, an arc distance of 74.70 feet to "a point front which
the center of said curve bears south 77 ° 46'39" east; thence sou E1ve0
88 16'T7" east 380.95 feet to a point from which the point of TUKW8.4
beginning bears south 01° 42'28" west; thence south 01° 47'28
151.49 feet tc the point of beginning. Subject to a utilities S 9 1998
eas -ment over the north 15 feet thereof. PEnMRCENfER
D 'Ys -U3a
• a
N
a
el 6
I9
10
0
a
N
a
ti
m
• 0
11
^ } v
L o 9
rr 0
ie i
W M
sheet
" r101011. ims
0
5
c.
z
-4
° j 5
UP
r)
�
0 Cl � i
•
0
a
N
K.4
x
z
N a
lance mueller
& associates
architects aia
130 lakeside • seattle wash. 98122 • 209 325 2553
1>UII.t7f 1--.1G R�MOD�I.
PI�I '1 OURC CCRPORAT
5 TREGK P i / TUKWII—A kV
° REGISTERED
y
'CF P. MUE115
ITECT
aac or WASHINGTON
job no.
drawn
checked
7. 9.'75
data no
revision
date