Loading...
HomeMy WebLinkAboutPermit D98-0322 - SEATTLE MORTGAGE - REMODELD98 -0322 •6450 Southcenter Blvd. Seattle Mortgage City of Tukwila < Parcel No: 000320 -0011 Address: 6450 SOUTHCENTER BL Suite No: Location: SUITE 106 Category: AOFF Type: DEVPERM Zoning: 0 Const Type: V -N Gas /Elec.: Units: 001 Setbacks: North: Water: N/A Wetlands: Contractor License No: KELLYTI148CR DEVELOPMENT PERMIT .0 South: .0 Sewer: N/A Slopes: Y (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: Issued: Expires: D98 -0322 ISSUED 10/20/1998 04/18/1999 Occupancy: OFFICE UBC: 1997 Fire Protection: SPRINKLERS East: .0 West: .0 Streams: OCCUPANT SEATTLE MORTGAGE 6450 SOUTHCENTER BL, TUKWILA WA 98188 OWNER ROYAL COACHMAN ASSOCIATES 8009 SOUTH 180TH STREET, KENT WA 98032 CONTACT LEONARD BERHHOLFT Phone: 253- 274 -0244 702 BROADWAY, SUITE 201, TACOMA WA 98402 CONTRACTOR KELLY THOMAS INC Phone: 253 - 735 -3928 3402 C ST NE, SUITE 209, AUBURN WA 98002 ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INTERIOR OFFICE REMODEL, WALL CONSTRUCTION ON INTERIOR. PUBLIC WORKS ACTIVITY INCLUDE MODIFI- CATION TO THE EXISTING DDCVA INSIDE THE FIRE VAULT ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 42,515.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: JJS Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: Y No: ' Size(in) .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * TOTAL DEVELOPMENT PERMIT FEES: $ 975.03 *************************************************************** ******************* Permit Center Authorized Signature: .� Date: /a-AD -q I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development per 't Signature � _ � Date: 0? Print Name: jj d., v u This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work 1s suspended or abandoned for a period of 180 days from the last inspection. Address: 6450 SOUTHCENTER BL Suite: Tenant: Type: DEVPERM Parcel #: 000320-0011 CITY OF TUKWILA Permit No: D98-0322 Status: ISSUED Applied: 09/22/1998 Issued: 10/20/1998 *1***A k** k klt*** A A I* k* k*** k* * *** *** A k**** k ***** k****** le** k* A A***** A Ic A *A Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the-TukwiJa_Building Division. 2. Electrical permits shallOtainedthilpugp the Washington State Division of,1a6or-ind work will be inspected by that agency (24e=66#():.„ 3. 'All mechanical, wo rk shall pe by the Ci 1 a 4. All permitSOnspeCtron and"apprOV,ed,planiall be available at the 5t)6 site prior to 6*, structi*.. These documents are to be maintained and aval able until final inspection approval is granted. 5. All construction to be done In conformance with approved plans and'requirements'of the Uniform Building Code ,('1997. Edition) as amended, ,Uniform - Mechanical Code (1997 Edition). andWashington,State Energy Code (1 Edition). 6. Any' new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic , Zone 3. • 7. Partition walls attached to ceiling grid must be laterally braced if over eight (6). feet in 'length.. 8. Any : exposed ins hacking material shall have'a Flne Spread Rating of 25 or less', and . iiiiterlal'shall bear tdentl-,;; fication showing the fire perforilince 9. Validity of Permit. The issuance of ;,Perait_or aPprOal'o plans,, specifications, and computations shall 620117 : strued bea permit for, or an approval of.: any vroTation of any of the provisions of the building code: or of any other 'ordinance of,the jurisdiction. :No permit presuming to give authority, to violate or cancel the 'provisions of th'W code shall be valid. , 10. VENTILATION IS REQUIRED FOR ALL NEW ROOMS AND SPACES OF NEW OR EXISTING BUILDINGS IN CONFORMANCE WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, CHAPTER..51,13!WAC. 11. "" PAJBLIC 'WO, R'KS 12. THE APPLICANT MUST NOTIFY THE CITY UTILIT MR GREG VILLANUEVA @ (206)433-0179'01COMMENCEMENT AND COMPLETION OF WORK AT LEAST 24 HOURS IN ADVANCE, REQUIRED MODIFICATIONS TO THE EXISTING DETECTOR DOUBLE CHECK AND VAULT ASSEMBLY SHALL BE COORDINATED WITH THE CITY UTILITY INSPECTOR. 13. EXISTING DETECTOR DOUBLE CHECK VALVE ASSEMBLY AND VAULT SHALL BE MODIFIED BY INSTALLING A GRAVITY DRAIN TO PREVENT STANDING WATER INSIDE THE VAULT AND ADDING TEST-COCKS TO THE DETECTOR DOUBLE CHECK ASSEMBLY. 14. UPON COMPLETION OF REQUIRED MODIFICATIONS THE EXISTING BACKFLOW PREVENTION ASSEMBLY SHALL BE TESTED BY A CERTIFIED TESTER AND ALL TEST-COCKS SHALL BE PLUGED'AFTER THE THE TEST. THEREAFTER, ANNUAL TESTS SHALL BE PERFORMED AT OWNERS EXPENSE, AND COPIES OF TEST RESULTS SHALL BE PROVIDED TO THE CITY. Project Name/Tenant: A-11 Lc, M O R:C G A -LSE Existing use: ❑ Retail El Restaurant ❑ Multi- family El Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ® Office ❑ School /College /University ❑ Other V lue of Construction: 1- 2. CIS , v �— Site Address:, City State/Zip: : ( 0 6 1 6 ;0 ( NCt�rt✓2 e ) W > 7 ,Co I D (0 "To1 . Tax Parcel Number: 00 03 .0 - 001) --00 Property Owner: 1 LD/1C IiMl�rNI A DG, Pho : (a LIY -4200 Street A9ress: q - I eR - itit. BLv f7 , SU►lt� „acs :7 0K'Ada- )- City State /Zip: S ul li < Fax #: Contractor: Vt li-q - ro -o,-, r> -I_ tit; ff r i 1 q-56R Phone: Street Address: r City State /Zip: Fax #: Archite ►2 �Hv �� SSv�ATE ( / Ph o �e s) j 97 -0 .44 Street Address: ,A A(Ow ( oirE 0-01 •Tlkomf.vuf q - 1"0,A h City State /Zip: q 0 . )-. - Fax #: , 'Zr ;3 L 1 30( Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: LcoNio S f� �E�ft - PI1 --T Phon c2s3) ei n 4 .-61 24-4 Street Address: 1 A . v i } `1 . Su I it: 701 ri}-51 f ) . t,w City tate/Zip: Fax it 6 709'0 2 - ( (53) ' - 7 ' 30k7 e Description of work to be done: j ►J cEtt (Ogg OFF1 L E CivI00€,L- 1 "ALA- CONS-I T tLCT( OpJ i Existing use: ❑ Retail El Restaurant ❑ Multi- family El Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ® Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail El Restaurant ❑ Multi- family ❑ Warehouse ElHospital ❑ Church El Manufacturing ❑ Motel /Hotel ❑ Office El School /College /University ❑ Other Will there be a change of use? ❑ yes 171 no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑l yes 51 no I , Existing fire protection features: CA sprinklers El automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: t 4-, 524 existing Area of Construction: (sq. ft.) 6, s Sr Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 0 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKt''lLA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOL'L'OWING: (Additional reviews may be determined by the Public Works. Department) O Channelization /Striping El Curb cut /Access /Sidewalk 131 Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage El Street Use ❑ Water Main Extension in Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: El Miscellaneous ❑ Flood Control Zone El Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Data application accgpt� Date application expires: 5 Z- -iS Applicati taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM CTPE1.M1T.DOC 7/29/97 BUILDING D AG }iWNER OR AUTHOR AGENT: Signature: s^ ct.� -c� c, � , '` i , f ¢ � Date: 1)�� g Li-2,./ei Print na m� �� EL) lv � - T i Q ; /4 - 0 7 LI Y Fax #•� I 2 3 � 6 t7 1 Address•70,L 6 p - ()f1 n tti ,i - y ! Sol T ao t Cit /; b fp /4 . . lop) `) et o 7. ALL COMMERCIAUMULTI- • ILV TENANT IMPROVEMENT /A RATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ➢' ` Alt DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). El El Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THiS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPl RMl7'.DOC 1/29/97 kA **AkkAk A 1rkkA***** A* *Akk* A: hA*** Ak*A*A k** *hk*kAA *•kAhlk*A•.kA,k4:*,. CITY OF TUKWIL.A. WA TRANSMIT * Ak***** kA*/r* k 4ikh*/ Vk** l* A**•k k * ******k *:k *kAA.Akk *Fkkk *kAA: %** * * *A TRANSMIT Number: R9700851 .Amount: 602.b5 10/20/98 14 :03: Payment Method:: 4703 Notation: ROYAL 'COACHMAN Ini�t: TKF . Permit Na: D98-- 0322 Type: DEVPCRM DEVELOPMI N1 PERMIT Parcel No: 000320 -001.1 Site Address: 6450 SOU•CHCENTER BL Location: SUITE 106 Total Fees: 975.03 This Payment 602.55 Total ALL Pmts; :.. 975..03 Balance: .00 ************* ot***********. A************ iit * * *A * * **•h * * * * * * *S•ot * *sL * *•A Account Code. 000/322.100 000/345.830 000/386.904 401/342.400 Description BUILDING - NONRES .. PLAN CHECK - UTILITY STATE BUILDING SURCHARGE INSP, FEE •- FLH /LI /WM . Amount 573. 10.00 4.,50 15.00 ** k*A.** A*** A* AA** A k* A***•** A* kA* Ak A***** *+AA * *•A* *A * *A * * *:kh * * *A CITY OF TUKWILA, WA TRANSMIT .. Jc ;l ****: 5****.A ** *,i* *• *;H•**** ** 4** A• kAkk* **A *:49r•k:t.rt *A TRANSMIT Number: R9700835 Amount: • 372 „48 09/22/98 .1i i:i. Payment Method: CHECK Notation: ROYAL COACHMAN Init:::I3LH Permit Nos, D98-0322 .'f roe. DEVPERM DEVELOPMENT PERMIT Parcel No: 00032070011 Site Addr°eas: 6'450 I3OU'(HCENTER DL Total Fees:: 950 03. This Payment 372.48 • Total ALL Pmt Balance: 5x7;5!3 A *•AA *Al.* * * * * * *a * * *,1'A. 44*4* * * **AA +A * *' *A *k* Alt* *•kk * .A•A*4* *0 *s *Adr* Account Code Description 000/345,8:30 PLAN CHECK - NONRE” Project•?' Type o ••ection: A Z 7'O i 74/ 7,,11, ki . Date 3--Z--/9 Special instructions: /2 7 4 -y . Date wanted:�, a.m. -3— p.m Requester: Phone: ZO(a- 7B4- 7‘-i7f INSPECTION RECCC Retain a, copy with permit • INSPECTION NO. CITY OF TUKWILA BUILDING DIVI 6300 Blvd, #100,Tukwila, WA 98188 PERMIT NO. �g - a32z (206)431 -3670 P COMM ---� CV_ FrAIN Vt„ pproved per applicable codes. El Corrections required prior to approval. ❑ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project: Type of inspection: Jest, , Q Address: 61vf� Date called: y Special i n ttr uc ons. Date wanted: a.m. p.m. Requester: ,P 0 � Phone No.: INSPECTION NO. I Inspector: I I I Receipt No.: Rc'Y"f"`•m.mt 'y r'2 C3 K?!�* ti rvJi2"C �3f INSPECTION RECORD Retain a copy with per Approved per applicable codes. 1) 5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 (206) 431 -3670 Corrections required prior to approval. C MM NTS - f, C , f) k, 4 I r- S. ?/2 9g P.c E4 -cry O c M T- 3/2 /F9 Led Co p f� Agit p rimite Tri pot -ct.4 r > Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: otect: e v i s e Typg -gf Inspection: Vi v 1G1 1 Add , �� o soo h o...iter a Date cal le c y . g 1 Special instructions: Date wanten /'�Cri .myl p.m. Requester: �a iry) Phone: �/' 1 .N 0 Approved per applicable codes. INSPECTION REC Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 COMMENTS: Corrections require prior to approval. Inspector: Date: 4. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: F_ e VADAI Project: Typgnection: r -- t 1 Add - ess: er b(Vd. . Date called. 1 !, -- WI- 6 1g , Special instructions: < , .A . ,. v i 1 ilifV\ A MA Date wanted: _...‘ 6 cr a.m. Reqper: t It' - 1E3L0- -- 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: INSPECTION RECOO 996.—D3D- Retain a copy with permit i ge-41-bq re-A/4e- orrections required prior to approval. /if OMS 807719 PI-40 / 7-- C/46 PERMIT NO. (206)431-3670 El $47.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: , Pro c .6 �Y.(9 � 6 Type of �ysp ?ctj� Date called: Addr ss• f I /� i instructions: Date wanted:- / r. / 99 a.m. P.m. Requester: Phone No:: INSPECTION RED Retain a copy with rmit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 pproved per applicable codes. U COMMENTS: PERMIT NO. (206) 431 - 3670 C70-%4'-ES /77 zA/E_5?T Corrections required prior to approval. El $42.00 EINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Pr &A ,O -7A6 Type o e do A re • Date Called: Special instructions: Date wan �:/ a .. Requester: Phone No.: wrizomm Approved per applicable codes. 7.0 INSPECTION REQ"$D Retain a copy with mit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 , �J COMMENTS: 1W7? IL i 644: __ - 4, t s aAte- /7X. 000 - 5 - 0,4 G e S jQT (/is r- /1 -Tr ZAs7r Date: 9 9 Corrections required prior to approval. 7 / F $42.0 /REINSPECTION FEE REQUIRED. Prior to inspection, fee must . be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: Project: Type_of ins ectl Pah i �'. FY ', Q.z .ee 4 9 1 /1 s 6 e.. Addres ate calle Q 2 j S ecia ictons: _ Q Yw ljLv► i ��^ � f30y! ,,` Kr" „ �) f -i o Ca ij i �., si is-- ed/ Date wan Q 24(4 p.m. Requerty : Phone No.: P" 7 u .r e ' " gstii F � +Xa:+6 q a � y3 "" ?? a ; y t c� rx Rf. -3 ,sxrrev�.a f 7 f• .� 3r i - �vi M 'l. ;i': C\t.r hR� � Y ' �; ��'_ ^' "' Y �f wE' K�� S is h- ..;._.: .,u*Y1. -�. OFT - 09 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECPID Retain a copy with mit / 0) ;2Z PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: 41,64. at V.:/ dd 1 // / tee /v siv4,4 c-Pr Pry cc, }rc" frs —7% -71 5 c 7 ? /5,4 " 4e?c M1 s. sue; 6. , Date /ij l/ $4 0 REINSPECTIO EE, REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4 F ,17, "11Millrel:4147411011-TAMMIVIVir C C WOW City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name 7:-eig/771E 410/'76 6 Address yc, fve 8c. Retain,currept_inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authoriz Signature FINALAPP.FRM Rev. 2/19/98 ‘WernAgWV3MMTRM John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. 6 Suite # 4 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575•4404 • Fax (206) 57.•4439 • STORTZ PLAN VIEW .......••.••.....•.•.•••••.•..• COMPACTED FOUNDATION GRAVEL UNDER VAULT 1 6' MIN. -- 12 MIN. • 6' MIN. t IN 50' OF HYDRANT ............... .... s L2' MIN. 12' MIN. ELBOW DOWN 30' -45' BEND , TO BUILDING NOTES: 1. DESIGN FOR 4" THRU 10' DDCV. 2. SEE ATTACHED NOTES AND MATERIAL LISTING. ■ City of Tukwila DETECTOR DOUBLE CHECK VALVE ASSEMBLY AND VAULT Not to wile. DATE: 11/26/96 WS-1 1 i MATERIAL LISTING; 1. 3 SHACKLE RODS WITH STAR BOLTS AND ASPHALT EMULSION COATING. 2. 4 MIN. D.I. CLASS 52 PIPE. 3. PRECAST CONCRETE VAULT WITH HINGED STEEL PLATE COVER, DIMENSION TO VARY WITH SIZE OF ASSEMBLY. 4. O.S.HA APPROVED LADDER IF OVER 30" DEEP. 5. PIPE SUPPORT STAND UNDER EACH CHECK VALVE. 6. COPeER OR BRONZE BYPASS WITH AN APPROVED OCVA. 7. 3/4 WATER METER. 8. APPROVED ODCVA IN MAIN LINE WITH TWO RESILIENT SEATED SHUTOFF VALVES AND TEST COCKS. g, 10 ", 8', 6" OR 4" COUPLING ADAPTER, FL 10. 10 ", 8 ", 6' OR 4 "FL•PE D.I. CLASS 52 PIPE LENGTH TO FIT. 11. GROUT INTERIOR AND EXTERIOR ALL AROUND PIPE USING NON- SHRINK GROUT. 12. 10', 8 ", 6" OR 4" GATE VALVE FL•MJ WITH POST INDICATOR VALVE. 13. FLANGE TEE ASSEMBLY SIZED ACCORDINGLY. 14. FLANGED 90' BEND. 15. 4" OR 6" D.I. CLASS 52 PIPE FL•FL 16. 4" OR 6" 90' BEND, FL 17. 4" OR 6" 0.1. CLASS 52 PIPE, FL•FL 18. 6' 90' BEND, FL 19. UL LISTED 5" STORTZ CONNECTION WITH 30 OR 45 DEGREE ELBOW. 20. 6' D.I. CLASS 52 PIPE LENGTH AS REQUIRED FL•FL 21. 6" 90' BEND FL 22. SWING TYPE GRAVITY OPERATED CHECK VALVE WITH BALL DRIP VALVE TO BE INSTALLED HORIZONTALLY. DETECTOR DOUBLE CHECK AND VAULT ASSEMBLY NOTES; 1. BACKFLOW PREVENTORS SHALL BE FEBCO #806 OR APPROVED EQUAL. 2. SIZE VAULT BASED ON SIZE OF APPARATUS AND MEETING MINIMUM CLEARANCES. 3 . A SEPARATE DETAIL PLAN FOR VAULT INSTALATION AND SPRINKLER UNE MUST BE SUBMITTED AND APPROVED BY THE FIRE MARSHALL PROIR TO INSTALLATION. 4. MINIMUM APPARATUS SIZE SHALL BE 4 ". 5. VAULT SHALL BE SEALED TO PREVENT WATER LEAKAGE. 6. LADDERS SHALL BE REQUIRED WHEN DEPTH FROM TOP OF LID TO FLOOR OF VAULT EXCEEDS 30 ". INSTALLATION OF ALL LADDERS SHALL BE IN COMPLIANCE TO O.S.HA 7. LOCATE VAULT IN PLANTING AREA AND NOT IN PAVING AREA, UNLESS APPROVED BY THE ENGINEER. 8. FITTINGS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE REQUIREMENTS OF ANSI /AWWA C110/A21.10 AND CEMENT LINED (SEE APWA & AWWA). 9. PIPE SHALL BE DUCTILE IRON MEETING ANSI A21.51, CL52 & CEMENT LINED. 10. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION. AFTER COMPLETE INSTALLATION INSTALL PERMANENT PIPE SUPPORT STAND. 11. PROVIDE BALL DRIP VALVES ON F.O.C. CHECK VALVE ASSEMBLY OR AT BOTTOM OF F.D.C. RISER. 12. FIRE DEPARTMENT CONNECTION TO BE PROVIDED WITH ONE (1) 5" STORTZ CONNECTIONS AND TWO 30 DEGREE ELBOW. 13. ALL UNDERGROUND PIPING TO BE INSPECTED, FLUSHED, PRESSURE TESTED IN THE PRESENCE OF AN INSPECTOR PRIOR TO COVER AND CONNECTION TO THE OVERHEAD SYSTEM. 14. UPON INSTALLATION, BACKFLOW PREVENTION ASSEMBLIES ARE TO BE TESTED BY A CERTIFIED TESTER AND ALL TEST -COCKS ARE TO BE PLUGED AFTER THE TEST. THEREAFTER, ANNUAL TESTS SHALL BE PERFORMED AT OWNER'S EXPENSE. AND COPIES OF TESTS RESULTS SHALL BE PROVIDED. 15. CONCRETE VAULT SHALL HAVE ONE 4'4'4' OR TWO 3' STEEL HINGED DOORS. ■ City of Tukwila MATERIAL LISTING & DETECTOR DOUBLE CHECK & VAULT ASSEMBLY NOTEa t DATE: 11/22/96 WS -11 NOTE OCT -21 -9e 02:22 AM Re: KELLY - THOMAS, INC. 3402 C St. NE Suite #209 Auburn, WA 98002 (253) 735 -3928 FAX (253) 735 -5144 Fax AI �.U. I�Ia'Al2 01. 1.ARROi2 AND INDUS'IR1tS REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGISTRATION NUMBER CCO1 KELLYTI149CR 01/29/1999 EFFECTIVE DATE 02/19/1986 KELLY THOMAS INC 3402 C ST N E STE 209 AUBURN WA 98002 Fax: c ') C ~4_, ✓ (J L/ 0, h Pages: 1 of f Phone: Date: jp / e s ) Time: f2 , 0 Urgent 0 For Review 0 Please Comment 0 Please Reply 0 Please Recycles P.01 — -r TO: FROM: DATE: SUBJECT: City of Tukwila Public Works Engineering October 16, 1998 Seattle Mortgage 6450 Southcenter Blvd., Suite 106 Permit Number: D98 -0322 Contact Person: Leonard S. Bernhoft Phone: (253) 274 -0244 Department of Public Works NOTIFICATION OF UTILITY PERMIT AC ION Permit Center John W. Rants, Mayor Ross A. Earnst, P. E., Director THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON OCTOBER 16, 1998: Two copies of the confirmed Utility Permit Application and plans are attached for inclusion in the permit file. JJS /tkf CF: PERMIT FEE Fire Loop (Modify to exist DDCVA Only) $25.00 TOTAL: $25.00 Development File (with copy of application and plans) PW Utilities Inspector (with copy of application and plans) Finance Dept. (with copy of application) 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 • Fax (206) 431 3665 City of Tukwila John W. Rants, Mayor Department of Public Works Ross A. Eamst, P. E., Director NOTIFICATION TO RECIPIENTS OF PUBLIC WORKS UTILITY PERMITS All Public Works utility permits have a standard requirement listed on the first sheet: "THE APPLICANT MUST NOTIFY THE CITY INSPECTOR OF COMMENCEMENT AND COMPLETION OF WORK AT LEAST 24 HOURS IN ADVANCE. FOR AN INSPECTION CALL (206) 433 - 0179." This is being emphasized and brought to your attention due to an increasing number of developments where this action is not occurring. In some cases, construction has not been completed in accordance with permit conditions and City standards. In situations where required notification has not been given to the City Inspector, the developer is proceeding at their own risk and may be required to remove and replace non - conforming construction. You are urged to review each permit and set of approved plans thoroughly and comply with any conditions or requirements stipulated. For clarification, the City Inspector referred to above is the PUBLIC WORKS UTILITIES INSPECTOR, GREG VILLANUEVA, WHO CAN BE REACHED AT (206) 433-0179. Your cooperation in this matter is required and appreciated. ,A2r`/1 Cn..rf.rp..•�. An..lpa...� (,.i�p l /In • T.•� il� 1f�4C�r....n.. o01:R • pF....p. /9(7A1 417.0!7Q • C31,.,l10i: ACTIVITY NUMBER: D98 -0322 DATE: 10 -23 -98 PROJECT NAME: SEATTLE MORTGAGE Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # 1 After Permit Is Issued DEPARTMENTS: Bing Division Pub is 1Norll n DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete n Comments: TUES /THURS ROUTING: Please Route Routed by Staff Approved \PR- ROUTE.DOC 6/98 PLA I�EVI SLIP APPROVALS OR CORRECTIONS: (ten days) Fire Prevention Structural Incomplete (if routed by staff, make copy to master file and enter into Sierra) Planning Division Permit Coordinator No further Review Required DUE DATE: 10 - 27 - 98 Not Applicable ❑ REVIEWERS INITIALS: DATE: DUE DATE: 11 - 24 - 98 Approved with Conditions Not Approved (attach comments) REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE. ACTIVITY NUMBER: D98 -0322 PROJECT NAME: SEATTLE MORTGAGE X Original Plan Submittal Response to Incomplete: Letter Response to Correction Letter # DATE: 9 - 22 - 98 Revision # After Permit Is Issued DEPARTMENTS: B� Id ing Division b- z �g P ublic Works lbw G Complete TUES /THURS ROUTING: APPROVALS OR CORRECTIONS: (ten days) Approved _ Approved with Conditions ❑ APR - ROUTE.DOC 6/98 l PL N tRIEWRO SLIP Fir Prevention PT- 9 -7,-4 Structural Incomplete Please Route ❑ CORRECTION DETERMINATION: Approved ❑ Approved with Conditions ❑ AEG-- ❑ DETERMINATION OF COMPLETENESS: (Tues, Thurs) REVIEWERS INITIALS: REVIEWERS INITIALS. Planning Division Permi "t'Coordinator DUE DATE: 9 - 24 - 98 Not Applicable ❑ Comments: Routed by Staff ❑ (if routed by staff, make.copy to master file and enter into Sierra) No further Review Required DATE: DUE DATE: 10 - 22 - 98 E Not Approved (attach comments) ❑ DATE: DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: DATE: October 23, 1998 CITY OF` WKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, .Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL PROJECT NAME: TI Seattle Mortgage PROJECT ADDRESS: 6450 Southcenter Blvd. CONTACT PERSON: Linda M o e s c h SHEET NUMBER(S) 2 of 3 and 3 of 3 PLAN CHECK/PERMIT NUMBER: 098 "0322 REVISION SUMMARY: Reduce demolition of exti sti ng office space to opening two spaces of demising wall between the suites. Adding a hallway using one now existing wall and construction of an additional wall. "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: PHONE: 206x244.4200 RECEIVED CITY OF TUKWILA OCT 2 1993 PPAMIT (;ENTER kriAid 114 CITY USE ONLY Bldg. Planning Fire REVISION NO.1... Public Works 3/19/96 City of Tukwila Fire Department Fire Department Review Control if D98 -0322 Re: T. I. at Seattle Mortgage - 6450 Southcenter Blvd'.. Suite 41106 Dear Sir: The attached set of building plans have been reviewed by. The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for • your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 1OB:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10; 1 -6.9) Extinguishers shall be located so as to be in ,plain view (if at all possible), or if not in plain view, • they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and John W. Rants, Mayor Thomas P. Keefe, The Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phones (206) 57544O4 • Far (206) 575 4439 City of Tukwila . John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be. more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All.locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 5754404 • Fax (206) 57$443; City of Tukwila Fire Department Page number 3 required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. • Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 4.1.3.2.1) .7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. Thomas P. Keefe, R,e Chief 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) John W. Rang Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone.• (206) 575-4404 , • Fax (206) S7S 4439 (_. City of Tukwila Fire Department Page number 4 9. All new sprinkler systems and all modifications to existing sprinkler systems shall fiave fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submi to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. • (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The • Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone :: (206) 575-4404 • Fax (206) 57$4439 C City of Tukwila Fire Department Page number 5 Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) requirements based on type of.construction, draft stop partitions and 'roof coverings shaft be' maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) . • In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Thomas P Keefe, Fire Chief This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 Page number CC.: Fire Department Thomas P. Keefe, Ike.Chlef The Tukwila. Fire Prevention Bureau TFD file ncd X 5/ 0 1 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 ' Phone: (206) 57544404 • Fax (206) 57$4439 LANDSCAPE ¢ SOUi1ICENTEIE BOULEVARD Ex.r.srrNo. pO EGI' , VALve 45SEM 64 r}1. VAut-r 6 H.464. BE riara to THE SAT r$ PAGrr6,0 of rite c 'Ty (AI p.IsP£cro4 - 5 L4£ SEATTLE MORTSAGE 6450 SOUTHGENTER BLVD SUITE *106 SEATTLE, WA. 98188 - EXISTING SITE PLAN SCALE I" = 20 45E EenCT co..orrzoFIS 3 SCALE N.T.S. LEGAL DESCRIPTION PARCEL •A• THAT PORTION OF THE TAI. li 61WAM DONATION CLAIM NO. 40 IN TOWNSHIP 23 NORTH, 10446E 4 EAST, MM., IN KIN& CCttlr(, WAEIINSTON, LYING NORTHERLY OF TIE R81TON TIRE TREE POINT ROAD, AND LYING SOUTHERLY No SOUTH - EAGERLY EASTERLY OF MACADAM ROAD AND LYING WESTERLY OF 65TH AVENE SOUTH AS CONVEYED TO THE CITY OF T113'ILA 131" DEED RECORDED UNDER AUDITORS FILE NO. 1105100426; TOSETEER KIN THAT PORTION OF VACETED MACADAM ROAD ADJOINING AS VACATED BY CITY OF TUKWILA ORDIIVJGE NO. 61', RECORDED 110152 AUDITOR'S HOLE NO. 7103120429 AID VACATED BY CITY OF 11.KNLA ORDINANCE NO. 1129; RECORONS N0.1910130505. PARCEL 9' THAT PORTION OF THE {-H4. N. 61LLIAM DONATION CLAIM NO. 40 IN TOWER. 23 NORTH, RANGE 4 EAST, MM., DESCRIBED AS FOLLOWS, 55533a146 AT A POINT ON THE G@Ir62 LEE OF ME REITON -THREE TREE PONY ROAD MINER 2644 AT ITS UII61ISECTION WaTH THE MEET LINE OP SECTION 23, TOWNSHIP 23 NORTH, RANEE 4 EAST, WM, SAID POINT BEING IMEMEE25 STATION 05429.92 FROM WWT04 TFE SOTTSttST CORNER OF SAID SECTION 23 °.. EARS 501144 011'42' EAST 204406 FEET, THENCE SLUE 34'51'43' EAST 164124 FEET; THENCE ON A CURVE TO TIE RENT HHAVIN6 A RADIOS OF 45537 FEET; 360.00 FEET; DEICE SCUM/ 63'15'48' EAST 35918 FEET; THENCE ON A CURVE TO TIE LET H AVIV& A RAMIE OF 572485 FEET, 31000 PET; THENCE SOWN 66•51'48' EAST 116253 FEET; THENCE ON A CARVE TO TE LEFT HAVING A RADIUS OF11634 FEET 442.40 FEET; THENCE NORTH 7 EAST 20168 FEET; THENCE LEAVING SAD GEYER LINE OF SAID ROAD AND RUNNING NI1RT4I 0 EAST 27203 FEET TO TIE TILE POINT OF 6EAN1@IS, THENCE 69•:0' EAST 16500 FEET, MORE OR LESS, TO THE WESTERLY MARGN OF 65TH AVBLE SOUTH, AS CONVEYED TO TEE CITY OF TI.f1ILA BY DEED RECORDED ILNGER AUDITOR'S FILE NO7201O70345: THENCE SOUTHEASTERLY ALONG SAID Ii51E L,14AR61N OF 65111 AVENUE 5011114 TO THE NORTHERLY MARGIN OF TEE MACADAM ROAD; THENCE WESTERLY AND SLVTYES1E RLY ALONE SAID NORTHERLY KAREN OF 71E MACADAM ROAD 20000 FEET MORE OF LEST, TO A POINT FROM WATCH THE TRIG PONT OF 81152807158114446410161 0 EAST; THRICE NORTH O'14' EAST 9621 FEET, MORE OR LE55 TO TEE IRIS POINT OF BESINNING; TOSETER WITH THAT PORTION OF VACATED MACADAM ROAD ADJOINING A5 VACATED BY THE CITY OF TI.KW4LA ORDINANCE NO. 611, RECORDED UNDER AUDITORS FILE NO 1108120429, AND VACATED Bl' crlY OF TU.YNLA ORDINANCE NO. 1129, RECORDED LTDER RECORDING ND. 1410130 PARCEL NO. 000320- OOII -0O VICINITY MAP •:pARATE PERMrt aEnUSED FOR: ECHANICAL ELECTRICAL PROJECT SITE} 0 PLUMBING 1 ❑ GAS PIPING CR't op Neu BUILDING woos 501 fIHLENIER o..._- _- FILE COPY I understand that the Plan Check approvals are 5ublect to 111015 and omissions and approval Of plans does ds authorize Receiptn hector Co of approvedl�lans acknowledged. tracmYscoPV eve Date Permit No. CITY OF TUKWILA APPROVED p T 1 9 1998 BOIL ING DIVISION �O FTU IA APPROVED PER PUBLIC WORKS SEP 2 2 }998 L�TER DATED to /6 - YS' /4 PERAI 221998 FAN C E0 a , ODCl/A 1'1400 tr c4rioN -s, '`,* 4 18 0322- O client THE MADISON CO. 415 BAKER BOULEVARD SUITE *200 TUKWILA, HA. 98188 (206)244 -4200 Project SEATTLE MORTGAGE 6450 SOUTHGENTER BLVD. SUITE #106 SEATTLE HA. 98188 I -800 -959 -0122 e � escrip Ion VICINITY SITE LEGAL drawn by MWP check by LSE scale . AS` SHOWN discipline date l - Ii -98 job. number SEATTLE MORTSASE 6450 SOUTHGENTER BLVD SUITE #106 SEATTLE, WA. 48186 DEMOLITION PLAN SCALE I /B° = I' CO OF 'MANILA APPROVED NOV 5 1998 e 7 .1 1:4 ON CITY OFETUKWILA O CT 2 3 19B PERMIT CENTER RE /.ZED ''O -2!-98 MYF Sheet Number client THE MADISON GO. 415 BAKER BOULEVARD SUITE #200 TUKWILA, WA. 46186 (206)244 -4200 Project SEATTLE MORTGAGE 6450 SOUTHGENTER BLVD, SUITE *106 SEATTLE WA. 48166 I -800 -959 -0122 Sheet Description DEMOLITION PLAN drawn by MWF check by LSE scale date AS SHOWN N -17 -98 discipline 5/0' TYPE -X 61JB. - --.I EXISTING TEE BAR ALE. 2x4 511.5 I6' O.G. — - 5/b' TYPE -X OlOS. O TYFIGA- WALL SCALE 3/4" = I' ELECTRICAL SYMBOLS ter DUPLEX OUTLET It WEATHERPROOF OUTLET 1&- 220 VOLT OUTLET AS REd'D. IL�6.F.I. GROUND FAULT INTERRUPT 1 SPECIAL DUTY RECEPTACLE 5 SWITCH 5 THREE WAY SWITCH CEILING OUTLET CEILING LIGHT FIXTURE P WALL LIGHT FIXTURE • RECESSED CEILING LIGHT FIXTURE O EXTERIOR LIGHT FIXTURE Q SMOKE DETECTOR IIOV W/ BATTERY BACKUP 100 GFM EXHAUST FAN (V.T.O.) G2 tRT INDIVIDUAL STYLE HEATER 9 FLUORESCENT LIGHT FLOOD LIGHT THERMOSTAT ........:: OF WORK AREA c•MNT HALLS TO RE REMOVED IFJN HALLS SEATTLE MORTSASE 6450 SOUTHCENTER BLVD SUITE #I06 SEATTLE, A. 98188 NEW FLOOR PLAN SCALE I /8• = I' GENERAL NOTES: 'NESE GENERAL NOTES ARE TO BE USED A5 A GPPLEVENT TO THE SPECIFICATIOr6. ANY DISCREPANCIES FCRD ANC LING THE DRAWW6. THESE GENERAL NUTET AND TIE SITE CONDITION SHALL BE REPORTED TO THE ENGINEER ARE' WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT TIE CONTRACTORS RISK. TIE CONTRACTOR SHALL. VERIFY ALL AND COORDINATE DU-ENSIGNS ANON. ALL DRAWINGS PRIOR TO PROCEEDING WITH ANT WORK OR FABRICATION. Tie CONTRACTOR IS RESPONSIBLE FOR ALL BRACING AND SHORING PURR. CONSTRUCTION. STADARD, ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 1994 UNIFORM BUILDING CODE NBGI AS AMENDED A1.0 ADOPTED BY THE LOCAL GOVERN). FLIIC/PALITY. DESIST) CRITERIA: VERTICAL LOADS. ROOF. DEAD LOAD IS ESE LIVE LOAD 25 P5F (SNOW) LATERAL FORCES, LATERAL FORCES ARE TRANSMITTED FROM Tie ROOF DIAPHRAM TO SE SITAR WALLS. THE LOADS ARE TEN: TRAM® TO TIE FOUNDATION WHERE ULTIMATE DISPLACB'TNT IS RESISTED BY PASSIVE PRESSURE OF EARTH AND / OR SLIDING FRICTION. OVERTURNING 15 RESISTED BY DEAD LOAD OF TIE STRICTURE. 2. 11110. P= C0C5GTI, DESIGN HIND SPEED = 60 YR.!. EXPOSURE CLASSIFICATION B, IMPORTANCE COEFFICIENT 10. F DETERMINED BY 1151115 CR EQUAL TO 13 . METHOD 2 !PROJECTED AREA USED FOR CALCULATION Co EQUAL TO 061 Os ECOIAL TO 16.4 PSI. P = O0tx13z16.41ID = 14.1E PSF. 3. SEISMIC. ZONE 3 PER 1994 LIC. Fp= ZIC0p, Z =O3, 1 =1.0, Cp =0.75, Wp =DEAD LOAD OF PORTION OF BUILDING. SOIL BEARING PRESSURE, 2000 P5 ALL FOO5N166 SHALL BEAR ON FIRM, UNDISTURBED EARTH OR STRICTURL BACKFILL. AREAS OVER - EXCAVATED SHALL BE BACKFILLEP WITH LEAN CONCRETE (F0=2000 PSI) OR STRUCTURAL BACKFILL'. AREAS DESIGNATED STRUCTURAL BACKFILL' SHALL BE FILLED WIT) APPROVED WELL GRADED BAIKRIM MATERIAL. NANKIN DENSITY AS DETERMINED BY ASTM D- 1557 -70. CONTRACTOR SHALL EXERCISE E TREME CARE DURING EXCAVATION TO AVOID DAMAGE TO EARED LINES, TANKS, AND OTTER CONCEALED ITEMS. UPON DISCOVERY, DO NOT PROCEED WITH WORK UNTIL RECEIVES WRITTEN INSTRUCTIONS FROM EN611KER A COMPETENT REPRESENTATIVE OF lit 014ER SHALL INSPECT ALL ROOTING EXCAVATIONS FOR SOITABLITY OF BEARING PRIOR TO PLACEMENT' OF REINFORCING STEEL PROVIDE DRAINAGE AROUND ALL WORK TO AVOID WATER- OFTENED FOOTINGS. CONCRETE, CONCRETE. SHALL BE MADE WTH PORTLAND CEMENT ASTI' 0-150 TYPE I CR TYPE II, COARSE AND FINE AGGREGATE A554 C-33, CLEAN HATER AND POTABLE, AND TYPE A (HATER REDUCING), TYPED (WATER REDUCING AND RETARDING) OR TYPE E (WATER REDUCING AND ACCELERATING) ADMIXTURE ASTM C- 444 -SO AND SHALL BE READY MUTED PER ASTM L -04 UNLESS OTHERWISE MATERIALS: ITEM MINIMUM f ' c NORM1AL SLUMP 25 DAYS INCHES. MAXIMUM FOOTINGS 2500 PSI 5 ABS 2500 PSI 5 SLABS ALL OTHER CONCRETE 2500 PSI 5 • AT CONTRACTORS OPTION CONTRACTOR MAY USE MASTER SOLDERS SYNERSYOW PERFORMANCE SYSTEMS USING POZZOLITH ADMIXTURES TO PRODUCE PLOWABLE CONCRETE. MAXIMUM 5LWP SHALL NOT EXCEED MASTER BUILDERS CONCRETE TECHNICIAN SHALL ASSIST IN DETERMINING PROPORTIONS FOR 5F5 CONCRETE AND SHALL OBTRIN APPROVAL OF ENGINEER PRIOR TO EMPLOYING THIS PROCEDURE PLACE CONCRETE PER ACI 304 AND CONFORM TO ACI 60 (506) WINNER CONCRETING AND ACI 605 (305) FOR HOT NEATER CONCRETING. USE INTERIOR FEGHANICAL VIBRATORS WITH 7000 RPM MMINMI FREQUENCY. DO NOT OVER - VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION JOINTS OR EXPANSION JOINTS. PROTECT ALL FT4H.Y PLACED CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN DAYS AFTER POURING. PROVIDE CONTROL JOINTS AT 26' O.C. MAXIMUM FOR UNEXPO =NFD SLABS, INCLUDING TOPPING SLABS, I6' 0C. MAXIMM FOR EXPOSED WEBS. SUBMIT DRAWINGS WITH CONTROL JOINT PATTERN FOR ENGINEERS APPROVAL PRIOR TO PLACING. NON - SHRINK GROUT. MAKE FROM ONE PART ASTM 6-150 TYPE I PORTLAND CEMENT, ONE PART FINE SAND ASTM C-55, AND ONE PART 'MASTER -FLOW 713' BY MASTER BUILDERS OR EQUAL. MIX DRY AS CAN BE WORKED, OR MIX TO A FLUID CONSISTENCY AND PACK OR POUR SOLID TO FILL SPACE UNDER PLATES OR SHAPES. USE 'EFEEGO 636• FOR NONEXPOSED WORK FETAL RBNFOROEI'OlT (CONCRETE: ALL REINFORCING SHALL CONFORM TO ASTM A-615, GRADE 40 FOR •5 AND SMALLER, GRADE 60 FOR 56 AND LARGER DETAIL FABRICATE AND PLACE PER ACI 315 AND ACI 31b. SPLICES SHALL BE 24' DIAMETERS OR INK MINIMM FOR CONCRETE. NELDEP WIRE FABRIC SHALL CONFORM TO ASTM A-62 AND A -I65. LAP ONE FU L1 MESH ON SIDES AND ENDS. PLACE AT MIDDEPTH OF SLAB, OR AS SHOWN. STRUCTURAL STEEL, MACHINE BOLTS (MB) AND ANCHOR BOLTS (MB). ASTM A-307. DRILLED IN ANCHORS, 'PARABOLT' BY USM, INC., MOLLY FASTENER DIVISION 'RAHL BOLT', OR APPROVED EQUAL. EMBED BOLT INTO CONCRETE 1' DIAMETER MINIMUM, EXCEPT AS 5110141. CARPENTRY: PLYWOOD STRUCTURAL), SHALL BE GROUP I OR .RCM II SPECIES, CA GRADE EXPOSURE -I CONFORMING TO P5 -I-83. EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF SE AMERICAN PLYWOOD ASSOCIATION. FRAMING LUMBER: CONFORM TO HEST COAST LUMBER INSPECTION BUREAU (NCLIB), OR IESTERN WOOD PRODUCTS ASSOCIATION (WWPA). EACH PIECE SHALL BEAR THE YtCLIB OR KEA GRADE TRADEMARK. SPECIES AND GRADE: I. BEAMS: AND HEADERS: 'DONS FIR / LARCH' No. I 2. BLOCKING: 'DOUS FIR / LARCH' No3 OR N EM FIR Not 3. EXTERIOR STD WALLS: 'DOUS FIR / LARCH' Not OR 'HEM FIR' Not 4. THE MNfM ALL OF L OTHER STRUCTURAL FRAMING, .DOUG FIR' Not CITY Of jNKWILR GENERAL GERAL REQUIREMENTS: PROVIDE MINIMUM NAILING FER 1994 NBC. TABLE 23-1-6 P P R ° V �.�9 oR MORE, AS OTHERWISE SHOWN. ALL 000 IN CONTACT WITH CONCRETE NOV 5 OR MASONRY SHALL BE PRESSURE TREATED MATERIAL. PROVIDE GUT ' HASHERS WHERE BOLT HEADS, NT. AND LAG SCREW HEAD BEAR ON WOOD. FRAMING CONNECTORS. ALL FRAMING CONNECTORS SHALL BE ICBO J APPROVED. TYPE OF CONNECTORS SHALL CONFORM TO THOSE GAZED OUT Ot gJILDING DIVISION DRAWINGS OR AND APPROVED EQUAL. 'CONTRACTORS CALLED OUT ARE SIMPSON STRONG TIE CONNECTORS AS MADE BY SIMPSON STRONG PE COMPANY INC. SUBSTITUTION. SISST1MIONS MAY BE ALLOWED ONLY IF THEY MEET THE REQUIREMENTS OF THE GENERAL NOTES AND SPECIFICATIONS, AND APPROVED BY TIE ENGINEER- RECEIVED CITY OF TUKNIE..5 OCT 2 3 1993 PERMIT CENTER pc18-O3) tE /USED :0 -2'-9E MI-IF cc Descrip Ion DETAIL NEW IMPROVEMENT NOTES client THE MADISON GO. 415 BAKER BOULEVARD SUITE *200 TUKWILA, WA. 48188 (206)244 -4200 Project SEATTLE MORTGAGE 6450 SOUTHGENTER BLVD. SUITE #106 SEATTLE NA. 98188 I -800- 959 -0122 drawn by MWF check by LSB date � -17 -98 scale AS SHOWN discipline Job number 98 -53 Sheet Number 5 3 —of 3