Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D98-0333 - MORTGAGE MARKET - PARTITIONS
D98 -0333 6840 Fort Dent Way Mortgage Market, Inc. City of Tukwila ( Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188_ Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Contractor License No: FOUSHAC1580D OCCUPANT MORTGAGE MARKET INC 6840 FORT DENT WY, TUKWILA WA 98188 OWNER RADOVICH JOHN C 2000 124TH AVE NE B -103, BELLEVUE WA 98005 CONTACT FRANK HEFFERNAN 12277 134 CT NE, #203, REDMOND WA 98052 CONTRACTOR FOUSHEE AND ASSOCIATES Phone: 206 746 -1000 BOX 3767, BELLEVUE, WA 98009 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: CONSTRUCTION OF OFFICE PARTITIONS AND DEMOLITION OF OTHER OFFICE PARTITIONS. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 20,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: :Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: ***************************************************** * * * ** * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 534.56 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. 2 Signature: Print Name:____ 295490 -0425 6840 FORT DENT WY SUITE 130 AOFF DEVPERM RCMU III -1HR 001 North: .0 South: .0 East: .0 West: .0 TUKWILA Sewer: TUKWILA Slopes: N Streams: DEVELOPMENT PERMIT ci Permit No: Status: Issued: Expires: (206) 431 -3670 D98 -0333 ISSUED 10/15/1998 04/13/1999 Occupancy: OFFICE UBC: 1997 Fire Protection: SPRINKLERS /AFA Phone: 425 -821 -3383 Date: ,/b 8 Date: _1_011S _ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 6840 :FORT DENT WY Suite: Tenant T;ype.: DEVPERM Parcel #: 295490 -0425 S k• k• k*• k**********• k**• k***;**• k*•k*• k• k*• k*• k*' k• k**• k,******• k*: k• k**** ** *••k *.4•k " k•k•k*•4* **•k'kkk;k Permit Conditions,: 1. No changer wi 11 be made to the plans unless .approved . by the ' Arch i tect or Eng i neer and t le,,..Tulww.i.,1,.a BO 1 d i ng Division . A ll 'permits, inspection reco:r ds and appr�ov.ed - plans she 11 be oval fable at the . }`ob site" TO prior • t o the ° at .an'v. con - struct ion • These ;documents ,'are. to, 'be ma in t`d1!d .,._,;and ava i 1- able until •final inspec t�ian approv'a;1 is g t anted Any new cei l �ng grid and ti, afht f °irtfir.>.e 1n i:s required to nieet lateral brae ing.,r�equirOt`s for Sei s:n ric Zone 3 r; a: , 4 ,,, en > . A - 4. Partition galls a.t.tachei to .iking. grid s `:` mu be 1 °la,ter'e. braced :i over :,feet in'�':�:l,ength. �t,' e r � 5. All cvn,str.uction t be One }i .conformance with ap,pro�,'ed Fz, plans ` and t r�equ i rements ;,cif the •Un if Bu i i di . ng `Code (;19975 Edition) as ,,a mended, 1Unif orni . y ?Mechanical Code (1997 . E .dti`�t''i,on �) .and ,Washirigtin, ;Energy ,Code (1997: Edition) $ rY�: : '',; 6. Vafldity. o .Permit:.. The isaii�ance of , perm or approv 1 plans ec i sp t i cat ions `arid conputat,ions ~shall not b ct n strued to be a'perrm.tt t'ar, ja,n• approval eti.•any violation of a',ny of the rirov,i ions of' \the'"build�tng.co Or of ,an�yr�� 4 other ord i.riance =,ot. ;'the ur i�sAi i ct t ons ;; N.o., s: pernii t preurni n9 ,n e = givauthority t v:1o1•ate'or• cance1y't .pro visions of this• codee,shal"f. valid • ..,..- u 7. VENTILATI.,ON I5 REOUIRED FOR ALL'',NEWAOOMS AND..SPACES OF NEW. OR E,f,'IST.IN,G> BUILDINGS IN CONFORMANCE: W.I'H.- 'THE..UNIF.ORr'I ,.._. BUILLDING . ,CODE AND THE WASHINGTON ; STATE;,•VENTILATION' ANC INDOOR'.. '7UALITY, CODE, CHARTER?51 : -13 ;WPC. } CITY OF, TUKWILA Permit .No: .D98 -0333 Status: ISSUED Applied: 10/02/J998 Issued: 10115!1998 Project Name/Tenant: MORTGAGE MARKET INC. Tenant Improvement Value of Construction: $20,000.00 Site Address: v j30 City State /Zip: 6840 Fort Dent Way - Tukwila, WA 98188 Tax Parcel Number: 295 - 490 -0425 Property Owner: John Radovich Development Corp. Will there be rack storage? ❑ yes X a no Phone: 425 - 454 -6060 Street Address: 2000 124th Ave _ NF 18103 - BP11P_VIIP_ City State /Zip: WA 98009 Fax #: 425 453 - 9740 Contractor: Foushee and Associates Inc. Phone: 425 - 746 - 1000 Street Address: 3260 SE 118th Ave. Bellevue, WA 98009 City State /Zip: Fax #: 425 - 746 -3737 Architect: FERRARI DESIGN GROUP PS ARCHITECTS Phone: 425 - 821 -3383 Street Address: 12277 134th ft_ NE #203 Redmond_ WA City State /Zip: 98052 Fax #: 425 - 821 -3213 Engineer: N / A Phone: Street Address: City State /Zip: Fax #: Contact Person: Frank Heffernan AIA Architect Phone: 425 - 821 -3383 Street Address: 12277 134th Ct. NE #203 Redmond, WA City State /Zip: 98052 Fax #: 425 - 821 -3213 Description of work to be done: Construction of office partitions and demolition of other office partitions. Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel X X 471 Office . ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel X X Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes X ri no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes X a no Existing fire protection features: X aX sprinklersX x113 automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 39,275 existing 1 Area of Construction: (sq. ft.) 3,000 S f ± Will there be storage of flammable /combustible hazardous material in the building? ❑ yes X X® no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Commercial / Multi - Family Tenant Improvement / Alteration Permit Application CITY OF TUI Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVILiPLAN REVIEWEOF.THE:FOLLOWIN (Additional reviews may be determined by'the'Publlc Works•Departnient) :` ` ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone Size(s)* cubic yds. 0 Fill cubic yds. ❑ Sewer Main Extension ❑ Water Main Extension 0 Deduct ❑ Channelization /Striping ❑ Fire Loop /Hydrant (main to vault) #: ❑ Land Altering 0 Cut ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous Date application accepted: /o - z-9 CTPERM!T.DOC 1/29/97 Date application expires: 1-. — 99 FOR STAFF USE ONLY ProJeci Number Permit Number: : ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Apply aken by: (Initials) I PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AUTHO'I 1 , GENT: OIL Signature: ii _ , , . / .... Date: • IraPa- 2. i 1 R$ Print name: tf K N ,,. / Ai Ph 532 City 1 383 F130 g2 1 1 32L Address 12 � t 134 G' ,.. L r 3 �tv , AO` M � /State /Zip �(�002 ALL COMMERCIAUMULTI -F/ LY TENANT IMPROVEMENT /AL i 'ATION PERMIT APPLICATIONS MUS BE SUBMITTED WITH THE FOL • WING: WI b ➢ ;1 13 E STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, 'TRUCTURAL tNGI EER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ a' Complete Legal Description Tr ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Tr Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names'of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). Floor plan: show location of tenant space with proposed use of each room labeled Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. Vicinity Map showing location of site Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. Indicate proposed construction of tenant space or addition and walls being demolished Construction details a ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. Tr ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance other land use or SEPA decisions. Pr ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) Er ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1 /29/97 j1b ".4 e!, , 4:1=olg7 . kkA:****:ahkhk*A *A* *:h * ** k ** A***: 4+* A** *A* ** ** ** *h* *** * * ****Jlk *l.;; CITY Or T.UKWILA. WA T RANSN:::... ** * **•k. *A** *•krtirz4k: :l It **** A* A * *;.* * **A *A *A• *•A * ***** *•F ** *:t :kAk:l* TRANSMIT Number: 89700848 Amount: '325M75 t0/15/98'1.3 Payment Method: CHECK Not.ti.on: JOHN C RADOVICH Init 131 Permit No D98•-0333 Type: DEVPEItM .DEVELOPMENT . PERMI ` Parcel No: 295490- 0425 Site 'Address: 6840 FORT PENT WY. Location: SUITE 130 Total Fees: 534.54, PW DCD 321.25. This Payment 325.75 Total ALL Pmts: 534.5'e..: F'W DCD 4.50 I3 al a n c e . CHECK 325.75 * *.A k * *A * * * **.** A**** A** AA**** A**; A* * * ** * * * *+1 * * * *A * * * *4*.*4 *•k* *"A 'b Account Code 000/322.100 000/386.904 Description Amount:.. ,. ; 10/19/98 .19 13 — NONRES 321.2' 16.41 0097 .6885. 8TAYE t3UILt'ING SURCHARGE 4185 .10. ,'., •,,,. •.. •, • CITY OF TUKWILA. WA TRANSMIT 1RANSMIT Number: R9700841 Amount: 208.81 10/02/98 13355 Payment Method: CHECK Notation: JOHN C RADOVICH Init BLH Permit No: D99-0333 Type: DEVPERM DEVELOPMENT PERMIT. Parcel No 295490-0425 Site Address: 6640 FORT. DENT WY Location: SUITE 130 • Total Fees: 534.56 This Payment 208.81 Total ALL Pmts: 208.81 Balance: 325.75 *itic Account Code Description Amount 000/345.830 PLAN CHECK - NOMRVS 200.81 •-- ---• t336 10/05 9717 'TOTAL P o'e : Iasi Lt../ - If Type o f ' • - : io • • • a. �1�0� Date ca = • . + - , _ / Special instructions: v . ,., Date wanted. a.m. Requester: DO 610 I Phone ( , -7 7 INSPECTION RECD r) Retain a copy with pi . lit INSPEC NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 ra Approved per applicable codes. COMMENTS: D4 -6333 PERMIT NO. Corrections required prior to approval. 206) 431 -3670 i Inspector, Date: $42.0, - EINSPECTI •J' - FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No.: Date: Pr ect: Pr yy < �" /arI �. T of i spection: ( �P,�; cov'.e.,✓. .Addy s 0 .t � Li 444444 W Dafe called / I f �3 /7 d Special instructions: f Date wanted: ti / j C, ID a.m. Z 1 < ( p.m. nn R eque r: 1 Wv0 Phon o : L) 1"" " y ' M n^ res.'A 'terrk - ci+ri;' 8 ;scrii*'3", ila3rs,S c4 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspec INSPECTION RECO ?' Retain a copy with p wit Date: Jqb' -a33 PERMIT NO. (206) 431-3670 Approved per applicable codes. G,PC'orrections required prior to approval. .: $42.Qb' REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.. Receipt No.: Date: u � (, j Type of inspernG Ain Project:( A s Date called: 1C Special instruct ons: t 1 Date wanted: W. ' (/ ( P.m. nester: 0 Pht .: v01/1310 INSPECTION RECOQ Retain a copy with p it INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS:. _ n Approved per applicable codes. Receipt No.: 1D o33? y'1 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTIOK FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: -- L1 i Type of inspection:p� Address: ccccccJJJJJJ Date called: Special instructions: Date wanted: / e 6 Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,' Tukwila, WA 9818 Approved per applicable codes. INSPECTION RECO Retain a copy with p it I PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: • Date: f6 $42,00 REINSPECT! Qfi1 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Receipt No.: Date: COMMENTS: Type of ins Fypection: n `� D • L e- e /c 44 i'y'7�, d Date calleido q / Special instructions: 0 S� ! 3o �Q� nn 1 . -- 'Z 179 r9 7"" 5. jr— t/4/6j 7 , / :`'= (C 7 6 - Z)( 4 77/e u �� Reques �: 0 M e aL�iL-1L. �-- Phone No (4 2.5)g6 q'1 0 S/ / -UGC Ce fl7S/ ehA ( c 1 ( 'ba. D i& '/ . 43 6 7/ T-toty / ,r'? O Proje t: OV fQ e I�'�C� -Y lLe�f ��►C. Type of ins Fypection: n `� L _ ! w Addre :g, 4 Fov '� Date calleido q / Special instructions: 0 S� ! 3o �Q� nn 1 . -- �.1 Date wa t lye Reques �: 0 M e aL�iL-1L. �-- Phone No (4 2.5)g6 q'1 0 ,JAS -o333 INSPECTION REC Retain a ci g py with p hit CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ] l,[ (206) 431 -3670 INSPECTION NO. PERMIT NO. Approved per applicable codes. p }- Corrections required prior to approval. Date: /0 $42.10 REINSPECTIQN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name P)� ' / 64c7t r7 tee T 2Nc. Address i 9{O c /(7 D T Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM i 4, Permit N John W. Rants, Mayor Thomas P. Keefe, Fire Chief :333 Suite # Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 11 -1S -1995 2:09PM I Y I FROI.1 JOHN C RADOV I CH DEVE 206 453 9740 32 - �•.�• -•• N'Jf 0 •.L .;1. .i t %, a I It0 ■ t ,t � n -, 1 II v ■ ; l `. 1 11' i . 1 II _. II t 0635 P. 2 Iii RECEIVED CITY OF TUKWILA OCT 02 1998 PERMIT CENTER 11-18-1995 2:09PM FROM JOHN C RAOOVICH DEVE 206 453 9740 C. ■ l' 7 7 - C i r ., Li.•;:. • ,. .. : . 1 er,". ,,,,, '..;. 47;771 r „ . g• 4 •tf • ! ] li, El ., g t. ..I; —1...--.7,...,.....150.•.... . r . I . 1 .---- i., '..,:, •:v.4:1, .... 1g, n / (..• • • • 1 i • t•■• — ? 'i •.: l'.• .... ao....—..• . 1.1 1 a r N--• Y / t • 4 ; . ,q* . I g 1 1 o '.. V?, ,... — b .............., : • ,••,... s ,,.. 11 v 0-. . ..., : r-- El; ■ .11%.1:', ' :. 4 ,' i:':, . _ ) ;.. e.....' : . , % 4 ::.: Yi t! .... .• P :, ., 1,;.,.., 1 .2. , t; ? J , , '••l' • ' .: ',,!? O t . ',.. .17,1 11 ;.',. 1 ;I'd %:0!' • - .‘ ii '''' ; s : r. . ! III ii ▪ i ht 1 ..— e l, [';......... I.11 wr j 1 : = ia 1 ii mno t r H. 1t • P . h t •,, . 111 i!! 1.1 113 a" • ri fit 1 I • 11 5 I .1 7 , RECEIVE CITY OF TUK OCT 0 2 PEW' P. 3 II.A 998 0 0 Li ac • • vomit um D018 3311J0 IMO AU VIVO NOISIO30 L__, ....„............,..„,...___ .., :. a or.. •■••", .....t • 3.... vc re? '.4 StAirCKTV !us rd • ▪ •- re 7.44 • t Use% " rip - • ••••■•••:. • 41 sr, ; • 2 -••••.,.. 44 I:e1---- - ':4 ' 1••.,::"...n.. • * •••••• • 1 ___1.---.• ---9--- c ................. • = ... • ,-,...-..1..,...-- 0 -f ...." 53:41744141arrtlii•27t4 14 44utc..” 4.1.441 CAA •14.141.01.4 4 . - 4:14 4* *111•10•2 4.116.m. ••••••:•••1 ma.r "tf."1.72.1.^-itglideVM112 • Wa , 11•11•11111 ..7.3:normnimmor.r.rxr4 - *VW 14 m, 'SU ear 1.11t.o• Wes •444w4 was fte •1 W WHOM Ws itta. • M••••••••C 4104■Nal StIPW 11111) .4 tins. Assiftio • ..• •-1 --. • — .. , i . --,........ 17J 1 LAW* * .41 ri ••-;.:=" •••• 1=1 a1)31 /1 11011 \Yr'. 10,00 010:011 3.1011111313k P bI3tdJ33iJ 31flO3S VOW • ▪ • - N••••• • 17 rrL .rtprie.10• •• • ■• • • - 510Za••_ ., ••=g1t •••ati..■••••■JtWaty ••••••,* ..44•••-•0•1•44,. T4..11 14111 - 2 =r:rr a *. rr•W•444:7‘. 103140 ' L V'0-- == a•••us- "••2/112112 • :•15.22110 riaT •••■••••■ >arr. 4 1.•411,s 11_±_bay AFt,.._41414.st itat 4 • i • J F 4. 1" 3 e v f . . , t ', - / 4 .. . .*.e 1 - •.SX - 4 - . .... XI ...,': . • . .. ...., i , .../.:4:7;- i . Tait *. - • - 1 Fz4 4„. y. „.• • .••■ . ...." • e.e._••••■•• • ..... - - 7 •-=--=. - - -7 . ;a -- -;=-;-.. - ;==" 7 - -- ---•-- — I --. - r es 4. • I _. " .,,, . ; 1. I : —t--'-..-- _=4.-- - -z , - - r 1 .. . -7.-.:1:..; -. - - -1 5 c° CC CD in OE F1 tff IL 'X t 7 iv -Ray ----- -% " - , 2%.••■•• • =•2,-C= •-•••••• ATI ir......." AO, ,•••••••. 1 •105111 Ol taa 4103 • 11 -19 -1995 2:10PM FROM JOHN C RADOVICH DEVE 206 453 9740 • • mai snow ono laoa _.ter 4. r___i:,:j 6 y \~ 1 • (j : it NO.OMNSVM 'V1IMW11 ONIC 1Uf8 3 O 1N90 11iOd HOIAOOVa •3 NHOr • ..w_ � IMF � nliJ.l I h t i' " • S \ . I • M \, • 1 ,dl �i Am. Ovelp■ N •/ .,. M Wit ".' 1 • t wa' ••.4. . • •- P. 5 • RECEI` ED CITY OF UMILA OCT o , 8 19 PERMIT oENTER DEPARTMENTS: ding Division C® V ( Cv. ( ublic TUES /THURS ROUTING: WR•ROUTE.DOC 6/98 C PtvmiF • C0yd PLAN REVIEW /ROUTIN ACTIVITY NUMBER: D98-0333 DATE: 10-2-98 PROJECT NAME: MORTGAGE MARKET INC X Original Plan Submittal Response to Incomplete Letter Response` to Correction Letter # Revision # :After Permit Is Issued Fire Prevention e. (0 —g-1 Structural DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Incomplete LI Comments: Approved n Approved with Conditions Approved ❑ Approved with Conditions E] Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) LIP Planning Division Permit Coordinator 5 DUE DATE: 10 - - 98 Not Applicable n Please Route n No further Review Required APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 11 - - 98 REVIEWERS INITIALS: DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: Dear Sir: c City of Tukwila Fire Department Fire Department Review Control #D98 -0333 (512) October 8, 1998 Re: Mortgage Market, Inc. - 6840 Fort Dent Way, Suite #130 Combustible material shall not be stored in exits or John W. Rants, Mayor Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the . following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 C City of Tukwila Fire Department Page number 2 Thomas P. Keefe, Fire Chief exit enclosures. (UFC 1103.3.2.3) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 A .•• .9 Page number 3 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property,' fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as . specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does.not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 ZO'd 900' ZS :ZT 86'ST 1 • • DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ;';; °••: J•,t. EXP {' "DATE': CCO ..; '!.. FOU8HAC15,8,OD. •08/12/1999 EFlEC�'PIVE "'DAT "' X09/0 . i• � .. .... �. • �;,:.' a �:•. ..�..,.> •.�w•..�• FOUSHEE & ASSOCIATES CO INC PO BOX •3767 BELLEVUE WA 98009 REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. * EXP. DATE CCOl FOUSRAC1580D'08/12/1999 EFFECTIVE DATE .09/04/1985 FOUSHEE & ASSOCIATES •,CO ;NC . PO BOX '37.7' :• BELL . 98'0' ' . Signature Issued by DEPAWIME OF LABOR AND INDUSTRIES TO966179SZt" °N 131 aaysno.r e-eIInf D`15-0333 A,ERSE- - 77555N OR FROOFTE5e OF 7,R, - OT° A T A ANN A.F-O45-E A, ORO 4. . CAS O CON SHA__ OR TO -5 FRA OE L9G A. NDEO AN: MOOTEE TO, T O. R_ 5FRIF AND A FIRE 5 . OTECTON TA AND AP RED, RED 5`" A_L CODES AND REG._4 - IONS ACCORDANCE CON'P, WITH REQ. .RE cNTS ,N T -SSE SPEC PCAT'C\- F OR STANDARD OF wOR<MANSTIP PERFORMANCE A, G.A., WHERE M.ATERIAL°_ ° D.IPNENT IS NOT 5°EC S.CALLY DENTIFED, THE ON WI 5'E R_ 7 TO SVBMN SAP LES 0 IN - DETERM N NS 0.54•AND PERFORMANCE TO TENANT/05.ER PRIOR TO ANY WORK. COORDINATE SLPP'_:ERS AND SSCONT , -ORS FOR SEOVENCE O= OFERATONS: PREVENT =LPL CA ON OF EFV Y FRO V DE ORDERLY °ROGR_°55 O< M' 2< F MANTA 'N STR.C,RA_ NTEGRI, OF BUILDING YEL' L ST...TIRE ANY IMPOSITION OF NBN LOADS ON EXISTING 55LONG STR:K -ERE SHALL BE RENEGED APPROVED B" A WASH `4570 STATE L'CEN5ED ETRUC:VRAL ENGINEER. CALCULATION'S AN© DE FALLS G.A_L BE PROVIDED FOR °B x1EM-AL P APOSES . ALL NN5' BE REMOVED - NORK VAS - KEE B,ILDING Omm E, ,, AREAS CLEAN AT ALL 711 ,c_ DURING INS COURSE OF CONSTRUCDON I.F. SCOPE OF CONTRACTORS NOR, TO 5E A COMPLETE TURNKEY CLEAN, OF THE ENTIRE TENANT SFAGE NcLUDNE, 54T NOT LNIITEP 70. NTERIOR In4 5 AND GLAZING A 1E OP Ex ER.OR GLAZING AND DOORS. CLEAN, N55NNO' _I,FAC= - . D TO THE N EDIATS WA.RK AREA. 5 - SRS TO PROTECT A5° -ALT S,FEACES et-x.0 E:.00KS OR S' ,DS FREEVENT DAMAGE TO PAVED 5, 2. SITE ROR - NONE 505) 6E, - AL_ '45R5 TG BE W.L 5 IN'TER'OR TO AN E,5 BOLD', 3. CONCRETE 4 ANT R_ 'R- A3 N^AN SLUMP OO PSI 23 5. ACKS PER C., XD. CO ¢� RE N SHAM- .IF ERT FA CE E= 311 MA -,NRY, NONE R= O'..R =D 5. METALS, FRAmNG GRABBER DR E2:IVALE.N- AS DETAILED DN DRANNGS F GOOK,. AS RELY RED BY CODE AST A 24 O_ °EN_ - RATE N. CONCRETE -,a MN M.M '5RASBER R OR - AANGS - _ _ _ ASTERS COLLT AND SH :M�CONNECTOF -E .� G AS R_CV.RED , COVER ATDN BE - AEEN D e,NLAR b. CARPENTRY e NG .N 01_. A__E_SOR 5 GRAB BARS ETC ... _ rOOD. NON_ RE, RED. ../S - OM -B1 LT L451NE'5 AS .E A_O ON DRAsINGS. ON __ L T NIERIORS OOEN S-E NG A NM NE AM NATE DRAFTSTOPS. N ✓NE R_OHIRED SHONE C.R BOARDS. N THERMAL AND MOISTURE PROTECTION. 15X'571440 - NO NSA DOORS .. 3 -3. CORE OAK E E NLESS NO _D OT,RASE /ER A N B. .-NG STANDARDS. INSIDE , ALL EX, DOORS O. O ¢ T 5 DG OR'. ST.OUT .SE O,N6 eTANOARD FRAY wRE GENERAL NOTES MORTGAGE MARKET INC. ER ES c DR , ARE _4E_' \ E 6z LD NOE AND F AD _'.TEE � H A_ CO F ORM �-O NS REGARENENTS °ER ON 5'AT CUES am REC., FOR BARRIER VERIFY NEY REGERESENTS ,- EMS AND G: FOR r CO . _ ._ N_ ALL,. O ON PR OR ANY nGRC. -O AND GLA5 N6 S.BCONTRA_ OR 5.ALL. Se R_ FOR ,DHE.RENCE TO -HE REDUREMENTS o' CHAPTER 24 OBC. 2 AN MODISCAT-ON OR ADD,. TO STOREFRONT FRAMING AND GLAZNG .lL C.. EXISTING STOREFRONT SYSTEM A. FINISHES, A. ELWR'.NG CONTRACTOR HILL BE REQ.., PED TO PELT "/ER F_.N ST,NG 5'_A5/51BFLOOR CONDIT O.NS A u AB;S:B�L JR .RE.ARATION REQUIRED °R'0.4 O I.NSTALLATON O< FINS, _OCR R. AL s W. tH n THE SCOPE OF ...RN. 2. CARFETNG E.NST N6 O RE AN. NC NEW NARK ,DER 1,1.5 FERMIT 3 CO. O_ TIO.N NC .NEW K5,<. T'DER THIS _R UT. 5. BAS. NO FEN NOP, UNDER THIS PER : - GONCRETE ,45 ALL AREAS OF CONCRETE SLAB THAT DO NOT RECEIVE A FLOORING MATERIAL SHALL LAVE BEEN SEALED NI, A CONCRETE SEALER. 5. GYPS, WALLBOARD. 5/5" 6YP55+ SOAR? TAPED AND READY FOR PANT. E. ATTACH TO OL. A A.EL ND ' l o< A, INTERID.R SUPPORTS. B 3" ,DE . . RESET. GYPS, BDARD REM:RED A A_L 5_9 5:0" TYPE ,. P BOARD AT A; RATE ' ASSHaL.ES ,DEN, FED ON oinr.IV65. LATEX F ND' COAT LA �. °RIMER A - AO COA N _ RIOR L _ F ' _ ENA n0E✓C_ _Ex •STUNG- NO NEW' HARK'✓:DER 10. SFR:IALTIES, NO NEN NOR‹ TD=F T »IS °EWA. II. EOUIRi41T - NONE REQUIRED 12. FURNISHINGS - NONE REOU.RED 15. SPECIAL WAGTRUCTION, 90. RE W RE T 14. CONVEYING SYSTEMS, \ONE R_WRED 15. MECHANICAL, 3. SEPARATE RM•T, A. ELECTRIC,. ISY SEPARATE ENERGY CODE INFO. THE AGRI, 0 TINS PERMIT IS SEINE PERFORMED A. TH;N AN EX STING ED BUILDING. 'rWICH BUILDING AAS'NSI,:AED IN EWASH WASHINGTON STA NON' RE_S'DEN' A- INGTON T CODE REONREVENTS TIME OF ITS CEIA5,,GTIO.N LAGER AN EARLIER 54ILDIN'5 4 ERN , LIGHTING T-E WORK OF THIS PERM, OF T ON EXCEPTION pNERGY COD I E.- SS THAN 60% OF L16HTING FIxTURE5 ARE NEW FIX,RES: IN A6 OF L EMT INE SERVING THIS 7i SPACE IS NOT INCREASED TENANT IMPROVEMENTS FOR: 6840 FORT DENT WAY , SUITE #130 TUKWILA, WASHINGTON 98188 LEGAL DESCRI PTION ATAN PORTON OF STREETS J ACJO.. v � SEC ON 23 AND 24 GNNS AORTA ORTA RANEE A EAST W M D S_RSEO BEGINNING AT HIGHWAY E'EER'S STATION v.Or. (121 i2,.0 45 T LINE SHOWN ON 004 THE STATE :MARY STATE REARAT .,. ( R 0 GREEN RIVER EXCHANGE. SHEETS. ESTABLISHED BY CO U555ON ,SOLUTION WW2. FEET,,, W. 1 THENCE NORTHEASTERLY AT RENT ANGLES TO 2TO'W EAST 2 536 FEET TO A POINT On r LINE A A D 214 LINE NORTH PARALLEL KAN AND 160 HT FEET WARRED A ANGLES NOR 0604 PLACE 05 5 THE SW W THAESTERLY MARE. OF VACATED KENNEDY STET (6130 5) OF AS SHOWN ON THE PLAT OF WAD../75 INTERURBAN ADDITION TO SEATTLE AS PER PLAT RECORDED IN VOLUME N OF PLATS, PAGE A6, RECORDS OF RNG C POINT BENS TIE TRUE PORT OF SEG.', OF THE PARCEL TO BE DESCRI HEREIN; THENCE FROM SAD TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59 EVEST TO THE SANK OF GREEN RIVER: THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOAING COURSES: NORTH 35 2' FAST TO A POINT LYING SOLTPH 30 NEST 33455 FEET FROM THE SOUTHWESTERLY L. OF THE LANDS CONVEYED TO KING CO.M, , STATUTORY WARRWARRANTY DEED RECORDED UNDER RECORDING NO. 7507300411 000 503 A, NORTH 50 EAST 53435 FEET TO SAID SOUTHWESTERLY LINE; THENCE ALONG SAID SOUTHWESTERLY LINE SW TH 59•5045" EAST 103.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LNUE CONVEYED TO THE WY OFT IT, BY CRATE CLAIM DEED RECORDED UNDER RECORDING NO. 1610230105: THENCE ALONG LAST SAID NORTHESTERLT LINE THE FOLLOWING COURSES: FROM A TANGENT THAT BEARS SOUTH 50 WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF be CO FEET AND A CENTRAL ANGLE OF 39'721•, AN ARC LEN2TN OF 5494 FEET; TNECE TANGENT TO THE PRECEDING 50,7 CURVE 50H 02 EAST 5269 FEET; I EEC£ TAN WIT TO THE PRECEDING COURSE ALONG THE ARCH OF A CURVE TO THE RIGHT HAVING A RADIUS OF 3200 ET AND A CENTRAL ANGLE OF 24•24'42•, AN ARC LENGTH OF 15.63 FEET: THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22 NEST 223.43 FEET; THENCE TANGENT O A RAO F 0000 FEET AND A CENTRAL ANGLE 0 TO 4060706 RIGHT AN ARC LENGTH OF 5910 FEET; THENCE TANGENT TO PRECEDING CARVE SOUTH 50 WEST 6632 FEET TO THE PRE POINT OF BEGINNING: XCEPT THAT PORTION CONVEYED TO THE CITY G TLN BY DEE0 RECORDED UNDER RECORDING NO. 705040599; SITUATED IN THE CITY OF RTGAILA. COUNT OF KING, STATE OF WASHINGTON. OWNER / AGENT, TENANT, ARCHITECT, CONTRACTOR, PROJECT CONTACTS JOHN RAWVICE DEVELDFIGENT COMPANY 20.00 A NE, SUITE 3103 04051. I.£, ETON P5005 PHO NE, (425) 5) 454 454.6060 (425) 453 -9140 CONTACT. CHRIS 5CALDO mown. E MARKET INC. 34515 PACIFIC Nhm 3,04 FEDERAL WAY , on NS 4 PHONE. (2336 6 23-2212 FAY (253) 250002 CONTACT, 6114 SOP AN 1 LAM. BROW 12? COAT NE... 20_- 3. NE.. (625)521 -5505 FAX (425) 521 -5215 CONTACT. FRANK HEFFERNAN, AIA FO)51C2 a 0550010TS5 T, WASHINGTON 91 O 5U 645 -LD PHONE. OU , (425)746 -5791 LICENSE NO.. FOJSHAC1500D CONTACT, DAVE MATIAS PROJECT DATA PROTECT ADDRESS, SUITE 9 190 65AOLA WA5NINOTOIN F ORT DENT WAY T ON 4 TYPE OF CONSTRUCTION, V -N' 5FRINKLERED OCCUPANCY CLASSIFICATION, B - EPEE TOTAL WILDING AREA, 36214 S.F. TENANT AREA, 1000 5,1. z SONS, HOREL:NE TAX PARCEL NO., 295.490.0425 DRAWING INDEX VICINITY P. SITE RAN. LEGAL DESCRIPTION, TAX PARCEL .NO. PROJECT DATA, PROJECT CONTACTS, AND GENERAL NOTES. PLAN,REFLE CEILING PLAN. KE DES. AND LE I, • VICINITY MAP PERMIT SEPARATE Ep FOR d MECHANIC AL ELECTPICAL 0 PLUMBING ❑ GAS PIPING RY OF TUI(WIIA EIU1LpING DiViSio I. t 1 1 1E .. aci;ls FILE COPY Printed DGT 0 2 1998 FERRARI DESIGN GROUP ri FERRARI DESIGN GROUP ARG111E01e, Pe Kin 203 RE MO%WMINciON 425 x.54123 )2065 .N1b42528( MORTGAGE MARKET INC. 8840 Fog Dant Way Suite 1/130 Tukwila, Washington 98188 !HOST IXFCRMA11E11: GENERAL NOTES; LEGAL DESCRIP.; PRJCT. CONTACTS; PRJCT. DATA; DRAWING INDEX; VICINITY MAP -JCR ' DEVELOPMENT 2000 1245 Avenue N.E. Sub OS-103 SNbrue, W22hln9lon 98005 MORTGAGE MARKET INC. 34815 Pacific FBA/. South 8uhe4104 Federal Way, Washington 98003 QRM By. D.n Oy H.raRawro OCT 9 2 PERMIT CENTER FH b98-o333 LEGEND KEYNOTES I. ZNIST, 3 -O -0' DOOR , REmA 2. , EONS 3 -C -, -0 DOOR NES _DCA' Oh S. NE6 3-0 3 T •-•O SG DOOR A, NRA, TO vATS- BALD, S A 3,, Ex S NS .ExITE TC• SE P. REAA ,, GARPET NEGESSARM PY NOTE , , XSGESBART 2 ! A-3 MATAL STUD FOR LA,RAL. SUPPORT ATTACH A/ 12) .6 ,RESS ,RE, TAB. EXTEND STD T O STRLDT3IRE VE BM GODS ' AGOSTIGAL GEIS,. BOARD x • ,Ao. TOP - RAGA TO MAX RUM3E32 OR CROSS TEE sOINT OF INTERSECTION 6/ (I, T s 3 6 5/6' 66B ENG. SIDE ATTACH Ai TYPE • SCREWS 0 6' PA,L EDDES FIELD. I/S X 25 SA MET, STUD 2 0.G. ATTAL. 90770^1 TRACK. 31/ I - INS DIAMETER RAY, DRIVE a 24'' AT GO, SLAB 3 VV 24 AT WOC70 VELA OFFICE PARTITION • • • FLOOR PLAN SCALE 1/36 3 REFLECTED CEILING PLAN NOM 50 08055505 ARE PROPOSED TO 1888 02151850 OEILINS/LIOHTII. LAYOUT (&A0 AND wn..1NK.Laz 5297E1-1 MOMFICATIONS (IF ANY ARE 551)11.72:0) HILL BE EIT EEPARATE PEWIT. 81.7011.0141.1014: FLOOR PLAN; REFLECTED CEILING PLAN; KEYNOTES; LEGEND Printnd OCT 02 1998 FERRARI DES,N OnUtln N 7 I -V FERRARI DESIGN GROUP 12177 13■111 suss au REINIOX0.1.0.610101 BK62-2.1.12 20018185 e5tit1.12121.X1 PROJECT MORTGAGE MARKET INC. 6840 Fort Dant Way Suite #130 Tulasila, Washington 98188 JCR DEVELOPMENT 2000 124th Avenue NE. 8280 88-103 Bellevue, Washington 98005 MORTGAGE MARKET INC. 34815 Pacific Haw South Suite #104 Federal Way, Washington 98003 cAvESADassaussoseloors OCTODFA 2.1900 2 CONSTIMMOX DRAMS A2