Loading...
HomeMy WebLinkAboutPermit D98-0354 - AZTECA MEXICAN RESTAURANT - DINING AREA AND PATIOD98 -0354 17555 Southcenter Pkwy. Azteca Mexican Restaurant City of Tukwila Parcel No: 262304 -9134 Address: 17555 SOUTHCENTER PY Suite No: Location: Category: ARST Type: DEVPERM Zoning: TUC Contractor License No: DYNATCC088CR Permit Center Authorized Signature:_ DEVELOPMENT PERMIT (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: D98 -0354 Status: ISSUED Issued: 01/14/1999 Expires: 07/13/1999 Const Type: V -N Occupancy: RESTAURANT Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: AUTO FIRE ALARM Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: N Streams: OCCUPANT AZTECA MEXICAN RESTAURANT 17555 SOUTHCENTER PY, TUKWILA WA 98188 OWNER MBK NORTHWEST Phone:`.206 575 -8090 C%0 TRAMMEL CROW COMPANY, .17560 SOUTHCENTER PY., TUKWILA WA 98188 CONTACT JRICK LENTZ • Phone: 425- 747 -3177 1800 136 PL NE SUITE 100, BELLEVUE WA 98005 CONSULTANT 'CHRISTOPHER BROWN & ASSOCIATES ' Phone: 425 772 -1188 879 RAINIER AVE'N #A -201, RENTON WA 98055 CONTRACTOR DYNA'TECH CONSTRUCTION CORP 1829 188 NE, ARLINGTON WA 98223 k*********** * * * *** * **** *.* * * * * * ** * ** * * * * *** Permit Description: CONVERSION OF AN EXSITING PATIO TO A NEW 590 SQ FT DINING.AREA AND A NEW 73550 FT UNCOVERED PATIO..PUBLIC WORKS. ACTIVITY INCLUDES STORM DRAINAGE FOR CONNECTING FOOTING DRAINS INTO THE EXISTING STORM DRAINAGE SYSTEM ON SITE, GREASE INTERCEPTOR UNDER A SEPARATE PERMIT MI98- 0241. k********************* k**************************.***** * * * ** ** * ** * ** */c * * * * * * * * * * ** * ** Construction Valuation: $ 54,766.15 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control' Zone: N • Hauling: N Start Time: :End Time: Land' Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized. Load: N Start Time:.. End Time: Sanitary Side Sewer:.. .N No,: Sewer Main Extension: N Private: N Public: N Storm Drainage: Y Street Use: N Water Main Extension: N Private: N Public: N . k.. kk' k************************************************* * ** * * ** * * * * * * ** * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 9,250.44 ****************• k************************ ' k********** * * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** Print Name: Eng. Appr: JJS I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development pernit. Signature: Date: _ _L_Ly 7 11 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUK.WILA type DEVPERM Parcel 4: 262304 -9134 •M •k •k •A 'A •A •k 1 k * A :L •A •A •k :k :k k k k :e ' A ' k k •k •k k •k - k A •k :k •k •k •k •k k :k k 'k k k k •k •k k :k •k •k • A ' A •k •k •k •k •A •k A •k 'k • k •k •k 'k • k k •k ' A •k * •k :A •k ' A •k Permit Conditions: .1. No changes will be made to the plans unless approved by the Architect or Engineer and the,TuI,.w:i;la Building Division. . Electrical permits shat- 1•- :;be' obta'::i;r ed; t:hr.,.ough the Washington State-Division of Lahor::a•nd an'd.a1� electrical: work will be inspesc ^t'ed by : that agency (243- 663t'):•._ . All mechanical :''iwor;k shall , be under ^ perm i the City of Tukwila 4. All permits,, 'inspection " ;records, an_d' approvedpl�ans .. hal l available at' the, job site prior to the start of any con struction The :documents are to be maintained and ava) r able ., ,m0 i l (A rial inspection ,appr ?oval is g ranted 5. All st.ructural concrete shal,'l be special insp`ectedr `(,UBC ;Sec 306(a)f Wheni!'specia'l inspecti,on` is required either the owner, architect-or engineer shall ,notify the Tukwila Bui)ding; Division of ' appointment of the inspection agencies prior th first 'bui, Cop.i special': insp`ectionreports:.:shal,.l b,e subm,it;t'e;d :to. Building . ?` Division in a timely manners R`ep�►rts : 'rshal:l contain addr.e ss prolect name, permit i;yp,e=`of' in being performed': 7. The speC i ail inspector shall submit 'a final signed report . stating whether the'" work requiring specia'1:�- inspection :was to the best-' the inspector's kn,owledge � ^ conformance'': with. approved Plans and specif ications• l and.. the app' icat le wor b mansh i p provisions of the UBC . ' ''. 8. Readily accessible access to roof mounted equipment is required. 9. Any exposed insulations hack ing 'materia.l ha.l`l have.` a F1.�ame Spread Rating of' ;: <25 or .less, and material. shall bear i,,den.t-i- fication showing the fire performance rating thereof.:-- 10. All construction to be done in 'conformance with approved plans and requirements of the ;Aln ifor MItBu i l d i ng Cod e" ("1997' Edition) as amended, Uniform Me'c hani'cal Code (1997 %-Edition) , and Washington State ..Energy Code J Edit,i,ori 11. Notify the City of 'Tukwila. Building Di „v.is-i:on- 'prior to placing any concrete. Th i sproced.u - e "f s in' i t i on to any requirements for special inspection. 12. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall valid. 13. VENTILATION IS REQUIRED FOR ALL NEW ROOMS AND SPACES OF NEW OR EXISTING BUILDINGS IN CONFORMANCE WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, CHAPTER 51 -13 WAC. 14. AAA PUBLIC WORKS 'k 15. The applicant must notify the City utility inspector at 206 -433 -0179 upon commencement and completion of work at Address: 17555 SOUTHCENTER PY Permit No: D98 -0354 Suite: Tenant: . Status: ISSUED Applied: 10/21: Issued: 01/14/1999 least 24 hours in advance. All inspection requests for utility work must also be made 24 hours In dvant.e 16. Teniporary erosion ; :control measures shall be implemented as the first order of business to p,reverit sedimentation .oft site or into exiatino'storm drainage facilities. 17. It is strongly recommended that storm drainage designs be c.er;tit ied by a l icensed • engineer; otherwise, the •owner 'ass"umes l i a b i l i t y for the des i,yri and any 'subsequent related ,damages .• The design and subsequent construction: shall .; b.e completed pleted in accordance with C.it..standards. Applicant shall ,submit an "A`=,_BUILT plan to Pub' i s ' Works ,prior to final sign -off. —The_ site' sha l l have permanent erosion control measures :place as soon as possible -after final grading has. been ;completed and prior. to the Final—Inspection. Project I G Y , j q 0g , , , / Value of Construction: 533 Site Adcjist� I !! fi ' )K\ rj 1 'wt ki4 �Str e /bip: rJ Tax P c �g Propert w er: azo Phone: ZO^ `((3 Street iy,l so SbI 60-1 Isitc v.tr.. rt. in SI,I eifiR 1 Fax #: Contracf 50 to ) + Phone: Street Address: City State /Zip: Fax #: Architect: CI 141 -11 •Ac 64'1'-001' (425) 7 3i1`1 Street I `0O(1 .t yy��,, PIS. f�1L' 1 1(4i IPD, '�Li LL 1(0 W� "l ottge /Zip: • Fax #:(AS) r 1 1 i _. 7 Engineer: Phone: Street Address: City State /Zip: Fax #: Contac)elrgok /0 Phone:( ) 74.,/ - ,vjl Street A tlb fl-. 4.10 51 IbD 5014 Vc)alvi 11gtta ip: Fax #: (+IA 1'fr7- ! 14 I Description of work to be done: ' jJ \ /O C.1 t,J4 5cf0 - 71)-41C? Ag -O>+gs o% ,4 4-1 g,4J yf o & f'/ ! i it To A Existing use: ❑ Retail fl Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail q Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? C_71 yes 121 no If yes, extent of change: Existing fire protection features: ❑ sprinklers 121 automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: IA -5D existing � . Wnew ,� ,p�� Area of Construction: 5 6 1 0 ►° e l Will there be storage of flammable /combustible hazardous material in the building? Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating ❑ yes CI no 5F �1U quantities & Material Safety Data Sheets CITY OF TUf Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 New Commercial / Addition / Multi - Family Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ❑ Channelization /Striping ❑ Flood Control Zone ❑ Moving an Oversized Load: ❑ Sanitary Side Sewer #: a Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous NCPERMIT,DOC 1 /29/97 APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: ❑ Hauling ❑ Land Altering 0 Cut cubic yds. End Time: ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public Size(s): 0 Deduct 0 Water Only Size(s): Size(s): Est. quantity: gal Schedule: Start Time: Size(s): 0 Fill cubic yds. Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: /0 -Z- -�B Date application expires: Appatlon taken by: (Initials) 4 PLEASE SIGN BACK OF APPLICATION FORM BUILDING OW R OOR AUTWORl ED- Signature% / / /1 ' Date: OGT. /G!' 4. Print ram : g.iG.K. i Phone: 7411„,31 t Fax ti: 'a_ 740 //mei Addresslb00 I i strgo pi,. 40 1 01 WO City /State /Zip: 1:901.4.06\100 ? Vhiel CI 005 •• y '", yt . 74,3 77 . ,. ', 4 r ' �i * *ic* *i.A * *AA *AA * *A **•A *A** *A********** A: 5• A** ** ***•kk * *•At ltA ki<_ # " * * * * *f CITY OF rul(3QILA, WA TRANSMIT *4 1,* * *tl *** *'A• * * * * * * ** ** * *.A * * * *•F•*** * * o� * * * ** * *sl * ***ickirA *'k *4. A *i* *•ki< •fttAi•lSMI : Number„ 89.500005 (imottnt: S 01/14,!99. ;10:41 Payment; Method: CHECK Notation: AZTECA RESTAURAN Irtitc BLH Permit No: '3D9€3 -•Q354 Type: DEVPERM DEVELOPMENT PCRM] Parcel No 262304•='-;134 Site .Address: 1 ?555 SOUTHCENT.ER . PY Total Fees. . This Payment 8,832.00 lotal ALL Pmts: 9 Balance: .00. ***A***** A' iit •**.AA* * ** *** *1%ilk* *•ka. * *7 iA * ** **fi*** * **ikisic4 *1 *1.ir.5l o *. AcA:aunt Code ( }00/322.1'00 000/345.830 000/345.830 000/386.904 412/342.400 104 «:367.000 Description Amount;, BUILDING - NONRES .260.21 PLAN CHECK • NONRES .441.19 PLAN CHECK - UTILITY 1Q.00. S•ft ;T.E:.33IJILGING SURCHARGE . 4. 40. INSP. FEE -• STORM DRAIN 1 .,:00 TRAFFIC MITIGATXON . FEES I3W 101 rO0 66:01/19:9717 TOTAL:., 8832.00.. 9 .1 .., 144:A*itil;1*******04—Il****44,1:* Airlei c Isitifi.*;1*****P;Icil***it*A*Ir4.4Vic**A*4i.lictk . CITY OF TUKWILA. WA . TRANSMIT TRANS \ • MIT Number: R9700852 Amount: 418.44 10/21/98 13:30 Payment t, - Method: ECK Notation: AZTECA RESTAURAN. Init: ;DLI-1 - ”---- - " - - - - - - - - - - - -- - -- - - - • - - - - - -- ---- - - - - - .... -- - - ..-- - ---- - -- - - - - - Permit No: 098-0354 Type: DEVP6,RM DEVELOPMENT 'PLRMIT Parcel No 262304-9134 Site Address: J7555 SOUTFICENTER PY , .. , • ' Total Fees: 1.101.34' This Payment 418.44 Total ALL Pmts: 418.44.- Balance: 682..90 A-.1,, Account Code Description , Amount 000/322.100 BUILDING NONRES 418'..44 Pr ject: T • • nspectioll Address: P ate al d M Special . 1 instructions: 1 PA Date : a.m. Req er: P'' 0 - - -te;sc3 — ' 5744 ( C Receipt No: I5 t' , INSPECTION RECD) Retain a copy with pt. knit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 Approved per applicable codes. n Corrections required prior to approval. COMMENTS: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. D98-0;35-r PERMIT NO. (206)431 -3670 Date: � Project: Type of inspection: sso Address: I7555 s -C. P Date called: i d Date wanted: t a.m. p.m. Special instructions: Requester: 11"4"—/Dy/LiA Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,' Tukwila, WA 98188 Approved per applicable codes. I Inspector: I I I Receipt No.: INSPECTION RECORD Retain a cops •ith per PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: q ).qqq, Neu-) -C i 'vw ctA a:M•.4 21CttH 4".o0tt.,,, ` °\4 frNil (6-m o ec t) & i Date: q $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: Aziecci Typrection: 1 i I no Address: I -- 1FF 50C:elltr P Date c II d: Li- 2.--q9 Special instructions: . Date wenied3 a.m. . . Re ique.5ter: IA rr rr It../ Phonr. -..... INSPECTION RE Retain a copy with p INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter ftivd, #100, Tukwila, WA 98188 Approved per applicable codes. ••■■111 Me-o PERMIT NO. (206)431-3670 Corrections required prior to approval. COMMENTS: e frt, MI 2? -02f f Inspector: Date: p# El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: ';•• • COMMENTS: Type of InspectiOr , r : p v - r - te_i;r1W ,.. C, 99 Special instructions: (0 --- - c lee koarskNII 1.: 64e- r ( 1 16y. . m. ( Requester: / 6) Phone:. / qic-,3ro (e732., ,.6;0' Pelees . 76=;gtx:=P-z-fop;fveiew ' 4 i; -1 0 -.. /se,e:_ 72,, ,4 44c," ProjeCt: it 71 Z■faa Type of InspectiOr , r : Addressi 7 5 _ 3 - s ._ Sc Date called: C, 99 Special instructions: (0 --- - c lee koarskNII ate wanted: . m. /7 /- P.m. Requester: / 6 f.x.0 Phone:. / qic-,3ro (e732., • ,f)r, rrrx•-•*,r‘., 'INSPECTION NO. OF TUKWILA BUILDING DIVISION 7. 6300 Southc nter Blvd, #100, Tukwila, WA 98188 INSPECTION RECO Retain a copy with pe7init 0 Approved per applicable codes. nA Corrections required prior to approval. $ .00 REINSPECTION FEE REQUIRED. Prior to inspecti n, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 3 s" PERMIT NO. • (206)431-3670 COMMENTS: f ht me ... .... Al ,e_ I Do kior Oc ctfes4 7 1 -1-1)T,Ob A*7 A 614 Pg o cor)6._ 6/5.77.cruy .2 /x.(•_s-7 7,te L rc) rie,e,- )›croe..s - Special instructions: P72(04 7 i )LtExr C:3. /_ LS/ 7 ---- • _ .a. rff , ,-- A-ror ta A ertg FM(14(„ 414 Co i D POISue, boo APPR-cun-L J i 4 .f / i / Pryiect: _.., T e bf Inspection: f ilgs s ..c. c eft...lc/ Date called37 4a , Special instructions: Date wid1 ‘- Req r: M) - -S '7 S INSPECTION NO. INSPECTION RE Retain a copy with CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 fie-0,34( PERMIT NO. (206)431-3670 LI Approved per applicable codes. rrections required prior to approval. 47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i Receipt No: Date: COMMENTS: 0. catirm jusz) OW I, Mg. OCC.00171t1 54• Rem ("Leo" rAcsve-tiPea 6 ,c/6(.(c_ (/ f ct.,?7,49-e_ a.m. p.m. rz4et fic;4._ h.9e4.- -A, Da 4--r" ---, Phone: ------------- i eti, , t_e4,27 - 704‘ .,.. /9 Project: 4 ..,, r Type d_Inspectioli: ' Address: I Date called: Special instructions: Date wa ed: a.m. p.m. Reque er: Phone: INSPECTION NO. Approved per applicable codes. INSPECTION REC Retain a copy with p Prf9-51-- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1.<5 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 orrections required prior to approval. Date: .00 REINSPECTION FfE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: COMMENTS: 1t..► o r 9- 04',1,5 7) ROLL 1> o tAJA-< Jr / poc,e..S Type��l�spe ' n: . -- cV /,4 f 4.i4w4-~ ,ir °c c0P t y . to ,00Ve 77 (/P-(I - 3o 07 - A1 e,ro ios - 4471 Nog A7 4cciES mac 6 0 c6417 $0 - rtf 0 i / /(f' We-c/-/. ".,c./ dwi',./AGr f t-(, _ ;? % /1 :" 1e.r.. t!�! '.fze:! %g ?jam 1 7� - �� -.. ; / J �4�/ �"'�. / 1... r'�.r� .� •n r /�If�,(r r'i�� {�t/'�r i11 ' 6 f/..&/..: ? .' 47 AA 4 44 - - Proje 0 ,,. Type��l�spe ' n: Ad r s: Date called: Special instructions: ! Date w 201% C� fi ^� Reques : Phone: El Approved per applicable codes. INSPECTION REC Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 D S o PERMIT NO. (206)431 -3670 rrections required prior to approval. $4 .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project 2 . Type of Ins ectroG i sir s3cenfcr p y Date called: Special instructions: -% * pOG.Cl \0(e , C uS‘k\ si t Date wanted: .... c f. Requester: ryc Ir. ph °I °311 E1S COMMENTS: Sr AitVE Coxix plovie SA-cL. ,,c( /8" , (y/,476 -- Afte/y z 5 4 - TX-->tccf-/. r9gerrec.7244 4E4//5/10-7LI Peak) 1 e-c.i> 0 )47e40(1 / S iei-br/406 1 o 1 (I ts'ne■t) ?_g..(/(seoA1 V P Pt,V P4( ci,--- 7 AP, 0 POW-. Ai at..4) Al it 62-4 .46 44 & / 2" 'cc e4-kter, /Afro :..,,t- K fivi4micfro IS 38. INSPECTION RE I I Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. 1:1 $47 0 REINSPECTION FEE REQUIRED. Prior to ins ection, fee must be paid . at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: TH1)- PERMIT NO. (206)431-3670 rrections required prior to approval. ' ' • COMMENTS: p ie :iz r - ii. 4 6, le."04(97:s, &4 ,411-/- /q-v,e 0 t Zg2.. -414t EAcAl C4/A e-xibbib. 1 e-xr.S7 6- al Reoc0 ,e2 4- ,g1,-(z:&709-7tr re9e. 1 iA - . p.-7WC.- ‘ G / . 77/ g L4 L7# edrrrecf /---ectced Ayr cc. P-, /4 Date want ......„. S fr, P.m. : 4 ,AeAn , , ProW Ty _af Inspection: fr9Z/Je Ad ress: ate cal)0: q4- 41 :Special instructions: Z AN ATI , ..-1 Date want ......„. S fr, P.m. : 4 Phone: ECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila WA 9818 INSPECTION Rik Retain a copy with permit PERMIT NO. . (206)431-3670 proved per applicable codes. D Corrections required prior to approval. ‘ I /Nei .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Phoject Type of IrySp�ct'on• ddr s:_ Date called? Special instructions: \(- Date w to : ! a.m..` p.m. Requ t Phone: ( 2,010 rc .c 9 7' INSPECTION N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 proved per applicable codes. INSPECTION REC Retain a copy with pe PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: 191:477- ` �.x�''�.s•�' govIA/AA7 j ?3 - 13•AC l e- /oNlz " 4t 4 67.4-7p $4 .00 REINSPECTION FEE REQUIRED. Prior to ins.ection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: commEr 4 j et 47 6-/(17 • (b ate-G cc-,e ,u 0 1 *7 0 e- iv Lc-ic, t 04-- TO Co Ift-e' Special instructions: ate wanted: / 3 t ( 7 AC (T A, 114 R.- COAJSrA./ 0 )0 k( 041 1— , 01/6 - O4r&W(71 1 Pezt/tx pc F,v wic,L ‘ .p... 1 VC Phore: A .. . A ,, Nject: . 1 C a—' T yReakfirsKV Arest Date called (17/r Special instructions: ate wanted: / 3 t ( 7 p.m. Request- . /0 0 Phore: INSPECTION RE Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 88 , PERMIT NO. (206)431-3670 pproved per applicable codes. ri Corrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No: Date: COMMENTS:. ' ' R4 e-e , 1 pp-- (#- cepotcA-rk, 22 3 -- / 13- A.,,,„.e:/ ,— , 3 _A) 7 1 ..-' .9 4 ii.p Ail ,911,, ) ,,,, L3 7 . 2 .,,,ym d (4 _I. ( r -a a- ei de .4 • ...... ....i . ; i . ,., . .. ' li.:. •' T -,--7 . .. Pr ect: Type nspection:' -;or. c cepotcA-rk, Datecal Special instructions: 1 a 4 g co ( C a.m p.m. Requ ter Phone: Oft,, STC 92(0 3" INSPECTION REC Retain a copy with p rniit INSPECTION NQ. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 0 3 5 PERMIT NO. (206)431-3670 i .Npproved per applicable codes. Corrections required prior to approval. Inspector: Dale: $47.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • COMMENTS: af:}47- 6, / 4 7 _ agegRE4__(e.(41 m2tfAi62 4 t /5 .t - //e Ae"-N /7" /5 /t.Ze 7 /9X4/.4/1- £ 9 .-,i ,v-,c717 (t/ e ---.. 4./e-to t>,to2, c4. .. . .4.. __4_, ,.: p /9-14,4ee,7.-4. le" at ae6 1) - /-ie64141f(ici(4-L 'go Or7 14 - / ic_( / Icr..ciow e- (A e 1 Project: C 6 Type of i inspectisn: 5 •.( Address: i . SS y S .(G-(c t \ Date called: . / ,.... Special instructions: ci Date want : Requester: f CI4 Phone: 3 • ,2 6 _ Inspect INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECTION RE c( Retain a copy with permit ir)S - 0 PERMIT NO. (206)431-3670 El Approved per applicable codes. -Corrections required prior to approval. El $47. 11 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No: Date: z)t( Project: Type 'Address: : r/g q 5 /y Date called: Special instructions: Date want d: 41- 7 a.m. p.m. Reques r. eiele■ie./ Phone: INSPECTION NO. Apprived per applicable codes. , INSPECTION RE Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 ..12Er.,,Corrections required prior to approval. COMMENTS: ___/Z6fee,(/ le _P€4/41 5/ AV I A° 4/2P6-4> Date: • El $47. 0 REINSPECTION E[E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: COMMENTS: Type of Inspec4ier: I J Ct Addr�s: 5 5 ` 7 S G Date called I Special instructions: tiAl /li t 7719 JU — m.�, Requester: +� vvi Phon C%' v( . G 75_ 24 1 //r 67 Z ` ,f /P /P /L .5 0//- /7 - I .4(/? 74 6 - 727 d(//‘ 4 ,e.7-4 ,e-e-- cgs /p- 9 ..8d-/ /Ti -20- 43/- 36 77 /€0019 ( ,. , Project: h z ‘ ecae Type of Inspec4ier: I J Ct Addr�s: 5 5 ` 7 S G Date called I Special instructions: Date wanted: 7r/ /"' y m.�, Requester: +� vvi Phon C%' v( . G 75_ 24 INSPECTION NO. Approved per applicable codes. INSPECTION RE Retain a copy with peP CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 .. �t..; w��... .: ° .'s.h .. !ar�i'tf= 3..w.!rolt3$S. if :i•.. .. ... ...r_ Vff23 PERMIT NO. (206)431 -3670 orrections required prior to approval. El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: COMMENTS: Type of Ireeorh poe....... Date called: l c? c.cit_rz.- .. ,e4 /r- ,4 Cyr ro g 2962 /4 /5729t,c... a.m. P.m. pe - n?" 6,0r 0e, 47 A.,C7 D 7 - .... 61490,14 e')1/612 c.14 4t-rAVIC-4_, r)i- 4f-65 .. _ _ . Pfri 431 I • ‘ INSPECTION REC Retain a copy with p mit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION .70 /- 6300 Southcenter Blvd, #100, Tukwila, WA 9818 (206)431-3670 Approved per applicable codes. ections required prior to approval. Insp /r e $4 .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dat Receipt No: Date: . ." • . ' "••■• ^••`.. ' • Type of Ireeorh poe....... Date called: Aildress: Special instructions: Date wanted: a.m. P.m. Requester: Phone: I • ‘ INSPECTION REC Retain a copy with p mit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION .70 /- 6300 Southcenter Blvd, #100, Tukwila, WA 9818 (206)431-3670 Approved per applicable codes. ections required prior to approval. Insp /r e $4 .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dat Receipt No: Date: . ." • . ' "••■• ^••`.. ' • COMMENTS: pgene.k, re /11,06_ /,,/ 4 5 1p6(444 0 2Ec 7 7 1 ( r" -3) d • l � .� 7i -‘/S Type o Inspection: CA utAct4A c-" 1 Rt7 ;L -- 47 C. 0,1-46c7 Address: 5C- R,5770.4- DA" 0--oDP WA4c 647 Date called: "9J Special instructions: A - 4 7 / 73i Od Date wanted: q 3 9? a.m. a go 0 P : 4 0 1 / / e . , 4' , '-- "Viet el ff C 6 r , Z - ,0- o , .O. 0 6t/AY/CS /CIO 7` sf C-,e1-7 I' c O - ..7 4 c E 47 c re i /19.e c - zz & et9-e- iL/07' 4 1 -We fil yelAioi/ e`rIh/z -,4.e - J( 4',eq :e4z`7 e 1.3 ie( Project: A-1....*f Q Type o Inspection: CA utAct4A Address: 5C- � Date called: "9J Special instructions: V Date wanted: q 3 9? a.m. a go Requester: Wu.4 Phone: 6.0, S 7S^ INSPECTION NO. INSPECTION RE Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved'per applicable codes. Inspectsf PERMIT NO. 206)431 -3670 rrections required prior to approval. Date: 397 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pic �, t Tg Inspection: Address: — 5C- " /75-5— i Date called: Date wan d: "f �+/ p.m. Reques er Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RE Retain a copy with /wit pys-to;5 PERMIT NO, (206)431 -3670 Corrections required prior to approval. COMMENTS: OA.. F 5 77/tc0 - DO IJOT C,tOco m. $ 7.00 REINSPECTION FEE'REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: P r ciro Type of Inspection: AOC;t #0/4/ l A c3ess: pjem i 5c. a Date called: Special instructions: Date wo7off / '. l r °°1316 1 Reques Phone: INSPECTION INSPECTION NO. • • INSPECTION R Retain a copy with ermit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 D9t3-T PERMIT NO. (206)431-3670 COMMENTS: 0 ,C /1 0 400 ,e(-&-4-77-/6-16 AP-40{2.- 7 Approved per applicable codes. n Corrections required prior to approval. 0 $47.00 REINSPECTION FEE REQUIRED. Prior to insp ction, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pro Act: , e of Inspection: , .. ' 0 - (eviS . rnecht rtirtj-r _c (6frt,.-4r i'fr". Date called:/ ( Special instructions: I Date wail e : (67 P.m. t Requ er: , arc Phon ( 6s/ .... j 9 I 0 Approved per applicable codes. INSPECTION RECO Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd, #100, Tukwila, WA 98188 g �3 9 PERMIT NO (206)431-3670 0 Corrections required prior to approval. COMMENTS: • 4 Poofev,e7 7 er Ae_cp/77,7 $47. a 0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: {H s.n..Y r .1^ m • Project Name Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: • Authorized"Signatuz'e' FINALAPP.FRM City of Tukwila Fire Department Address / 5 S, /c ?T,6- 4 ACpl CA-n/ x;7•14-uJ2I1N Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued ` � r/ rn/' /,/ 4? N A/ TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 r.� mx7F,Trie:n;tlrq°•�q ;rvmm o 5:x}.x'm FJIJfr , r I s John W. Rants, Mayor Thomas P. Keefe, Fire Chief ate Suite # T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tuk ' 1 ington_ 8188 • Phone: (206) 575.4404 • Fax (206) 575-4439 '••$. • '154e • ' )A 4z574 .5 7.7" ,1;.. , 147.: . • !: • •••• .•47 • • - .• • .3...--... • • • • ••••• ••••••,• , • a lute 12 - t •61":r 't • • .73.5f4 or Link . ,...... 7....rwidenfor n/s left turns .. -•: -., -... - 1.,...7,-.5-e....--.... , - • t/S R181 widen n/s and e/w • Andover Pk E/B akar • lefts, signal .... Andover Plc W/Minkler n/s lefts, signal • Southcenter PkWy/168 signal W Valley/Strander NB dual left turn lanes Interurban Bridge widen for dual lefts his i a "p 'nin' level" estimate. c Ye-wrjimt,,,k Future (Bera d 6 Minkler (APW - Southcenter PkWy) construct 3 lane street S 178 St (Southcenter PkWy-WCL) realign (cap/safety/transit) Andover PkWy (T PkWy-180) widen to 5 lanes' Andover Pk E (T PkWy-180) widen to 5 lanes @ ints. Southcenter PkWy (180-200) ' construct 3 and 5 lane street . 4oki/A4,),LL9- November 1993 • Mitigation Proportionate Fairshare Costs 1990 2010 Pk Vol Improvement Cost/ Pk Vol Pk Vol Duff Cost Trip 3,899 4,853 954 $134,000 $140 3,211 3,905 694 $94,000 $135 3,082 4,016 934 $296,000 $317 5,236 7,760 2,524 $1,200,000 $475 790 1,453 663 $250,000* $377 2,441 3,078 • 637 2,425 3,324 899 3,433 4,316 883 $250,000* $283 2,831 3,945 1,114 $1,250,000* $1,122 3573 t;45454giagg 1 0 1,015 1,015 789 1,424 635 1,112 1,833 721 970 1,420 450 408 1,600 1,192 $250,000* $392 o I 1/ <szA0Q021, 422 C3 123 60 121 op 1744 2 - C 1317 71 • City of Tukwila Washington . Ordinance No. / 7� AN ORDINANCE ' OF THE CITY OF TUKWILA, WASHINGTON, IMPLEMENTING THE LAND USE PERMIT CONSISTENCY AND CONCURRENCY REQUIREMENTS • OF RCW CH. 3630A, ADDING NEW CHAPTERS TO TITLES 9, 14 AND 18 OF THE TUKWILA MUNICIPAL . CODE, ;AMENDING CHAPTERS 18.66 AND 18.70 OF THE TUKWILA MUNICIPAL 'CODE, REQUIRING . s A DETERMINATION' OF CONSISTENCY WITH ADOPTED PLANS, LAWS AND POLICIES FOR ALL PERMIT • APPLICATIONS, . ESTABLISHING PROCEDURES TO DETERMINE 'WHETHER ADEQUATE. UTILITY AND TRANSPORTATION FACILITIES ARE AVAILABLE TO SERVE NEW DEVELOPMENT, AUTHORIZING THE IMPOSITION OF . MITIGATION CONDITIONS, • AMENDING STANDARDS FOR THE REVIEW AND APPROVAL OF SHORELINE SUBSTANTIAL DEVELOPMENT PERMITS, SUBDIVISIONS, AND ADOPTING STANDARDS FOR THE EXPANSION AND ENLARGEMENT OF CERTAIN UNCLASSIFIED USES. WHEREAS, RCW ch. 36.70A requires that no land use permit applications be approved until a determination has been made that the application is consistent with and carries out the-objectives of. the Comprehensive Plan, Development Regulations and other applicable laws and regulations, and WHEREAS, RCW ch. 36.70A requires that the City implement procedures to assure that utility and transportation capital .facilities necessary to • support new. development are provided in a manner which is concurrent with the occupancy and use of nevi development; and • WHEREAS, the City Council. seeks to provide more specific standards for the review of certain land use permits, . . • • NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, ORDAINS AS FOLLOWS: Statement of Purpose 3 CHAPTER 1 - STANDARDS FOR APPROVAL OF PERMITS 3 Section 18.57.010' Determination of Consistency with Adopted Plans and Regulations - Type 1 and 2 Decisions 3 • Section 18:57.020 Determination of Consistency with Adopted Plans and Regulations - Appeals of Type 2 Decisions • • Section 18.57.030 Determination of Consistency with Adopted Plans and Regulations - Type 3, 4 and 5 Decisions Section 18,57.040 Additional Findings - Reclassifications and Shoreline Redesignations Section 18.57.050 Additional Findings - Preliminary Plats CHAPTER 2 - UTILITY CONCURRENCY STANDARDS. Section 14.36.010 Water Supply - Concurrency Determination Section 14,36,020 Sewer System - Concurrency Determination Section 14.36.030 Mitigation CHAPTER 3 - TRAFFIC CONCURRENCY STANDARDS Section 9.48.010 Determination of Traffic Concurrency Required Section 9.48.020 Exemptions Section 9.48.030 Level of Service Standards Section 9.48.040 Arterial Classification System Section 9.48.050 LOS Standards for Specific Locations Section 9.48.060 Design of Arterial Improvements; Load Limits Section 9.48.070 Traffic Studies & Mitigation : Section 9.48.080 Mitigation of Traffic Safety Hazards CHAPTER 5 - MISCELLANEOUS Section 501 Severability Section 502 Effective date , Section 18.66.110 Normal upkeep, repairs, and maintenance; • replacement,of existing structures Section 18.66.120 Expansion of Existing Unclassified Use - Animal Rendering Facilities • Section TMC 18.66.130, Performance Standards for Rendering Plants Section 18.70.100 Conditional and Unclassified • Uses 3 62 7 10 CHAPTER 4 - ADDITIONAL STANDARDS FOR UNCLASSIFIED USES 10 10 10 6. 12 12 '12 Statement of Purpose CHAPTER 1- STANDARDS FOR APPROVAL OF PERMITS A new chapter 18.57 is added to TMC Title 18 as follows: • ... ...• • . • .... • .... . ... The purpose of this Ordinance is to establish standards for the approval of certain land use permit applications in the City of Tukwila. This Ordinance also establish standards for. determining whether utility and transportation system improvements necessary to serve new development in the City of Tukwila will be provided concurrently with the occupancy of such new development. These standards are consistent with and adopted pursuant to RCW 36.70.070. Section 18.57.010 Determination of Consistency with Adopted Plans and Regulations - 'Type 1 and 2 Decisions When the Department issues a decision on a Type 1 or 2 decision, the Department or hearing body shall determine whether the decision is consistent with, carries out and helps implement applicable state laws and regulations and the regulations, policies, objectives and goals of the City of Tukwila Comprehensive Plan, the City of Tukwila's Development Regulations and other official laws, policies and objectives of the City of Tukwila. The Department is not required to enter findings of fact or conclusions when issuing Type 1 and 2 decisions, provided that findings of fact and conclusions are required for Shoreline Substantial Development permits. Section 18.57.020 Determination of Consistency with Adopted Plans and Regulations - Appeals of Type 2 Decisions When a hearing body renders a decision on an appeal of a Type 2 decision, the hearing body shall make and enter findings of fact and conclusions from the record which support the decision or recommendation. Such findings and conclusions shall set forth and demonstrate the manner in which the decision or recommendation is consistent with, carries out and helps implement applicable state laws and regulations and the regulations, policies, objectives and goals of the'City of Tukwila Comprehensive Plan, the City of Tukwila's Development Regulations and other official laws, policies and objectives of the City of Tukwila. • Section 18.57.030 Determination of Consistency with Adopted Plans and Regulations - Type 3, 4 and 5 Decisions When a hearing body renders a decision on a Type 3, 4 or 5 decision, and when the Planning Commission makes a recommendation on a Type 4 decision, the hearing body shall make and enter findings of fact and conclusions from the record which support the decision or recommendation. Such findings and conclusions shall set forth and demonstrate the manner in which the decision or recommendation is . consistent with, carries out and helps implement applicable state laws and regulations and the regulations, policies, objectives and goals of the City of Tukwila Comprehensive Plan, the City of Tukwila's Development Regulations and other official laws, policies and objectives of the City of Tukwila. Section 18.57.040 Additional Findings - Reclassifications and Shoreline Redesignations When the City Council makes a decision regarding an application for a reclassification of property or for a shoreline environment redesignation, the decision shall include additional findings which support the conclusion that at least one of the following circumstances applies: A. The reclassification is for the purpose of achieving consistency with the Comprehensive Plan; or interest. B. The applicant has demonstrated with substantial evidence that: 1. Since the adoption of the last version of the Comprehensive Plan or Shoreline Master Program affecting the subject property, authorized public improvements, permitted private development or other conditions or circumstances affecting the subject property have undergone substantial and material change not anticipated or contemplated in'the adopted Comprehensive Plan or Shoreline Master Program; 2, The impacts from the changed conditions or circumstances affect the subject property in a manner and to a degree different than other properties in the vicinity such that rezoning or redesignation by means of a generalized amendment to the Comprehensive Plan or Shoreline Master Program is not appropriate; and 3. The requested reclassification or redesignation is required in the public Section 18.57.050 Additional Findings - Preliminary Plats When the City Council makes a decision regarding an application for a proposed preliminary plat, the decision shall include additional findings as to whether: A. Appropriate provisions are made for the public health, safety, and general welfare and for such open spaces, drainage ways, streets or roads, alleys, other public ways, transit stops, potable water supplies, sanitary wastes, parks and recreation, playgrounds, schools and school grounds and all other relevant facts, including sidewalks and other planning features that assure safe walking conditions for students walking to and from school; and B. The public use and interest will be served by the platting of such subdivision and dedication. C. If the City Council finds that the proposed subdivision and dedication make such appropriate provisions and that the public use and interest will be served, then the City Council shall approve the proposed subdivision and dedication. Dedication of land to any public body, provision of public improvements to serve the subdivision, and/or impact fees may be required as a condition of subdivision approval. Dedications shall be clearly shown on the final plat. CHAPTER 2 - UTILITY CONCURRENCY STANDARDS. A new Chapter 14.36 is 'added to TMC Title 14 as follows: Section 14.36.010 Water Supply - Concurrency Determination A. All applicants for Type 1, 2, 3, 4 and 5 decisions involving projects which will require domestic water supply and or water for fire flow purposes shall obtain a certificate of water availability from the water purveyor serving the area in which the proposal is located, if the site is served by a purveyor other than the City of Tukwila. The certificate shall confirm that the water purveyor has the necessary water rights and the water system capacity, including such water mains, pump stations and other facilities as may be necessary, to provide domestic water service and fire flow meeting City standards or that such capacity will be available by the time a certificate of occupancy is issued or fire flow is required by the City Fire Marshal to protect combustible construction, whichever is earlier. B. Applications for Type 1, 2, 3, 4 and 5 decisions involving projects which will require domestic water supply from the City of Tukwila shall be referred by the Department of Community Development to the Department of Public Works, which shall determine whether . .. .,_... the City has the necessary water rights and the water system capacity, including such water mains, pump stations and other facilities as may be necessary, to provide domestic water service and fire flow meeting City standards or that such capacity will be available by the time a certificate of occupancy is issued or fire flow is required by the City Fire Marshal to protect combustible construction, whichever is earlier. If adequate service is not available, the Department of Public Works shall determine and shall advise the applicant of the improvements which are necessary to provide service meeting City standards. Section 14.36.020 Sewer System - Concurrency. Determination All applicants for Type 1, 2, 3, 4 and 5 decisions involving projects which will require domestic sanitary sewer service shall comply with one of the following: A. Submit proof that the applicant has received approval for an on -site sewage system design from the Seattle -King County Department of Environmental Health in accordance with the rules and regulations of the King County Board of Health. B. Obtain a certificate of sewer availability from the sewer purveyor serving the area in which the proposal is located, if the site is served by a purveyor other than the City of Tukwila. The certificate shall confirm that the sewer purveyor has the necessary sewer system capacity, including such sewer mains, pump stations and other facilities as may be necessary, to provide sewer service meeting City standards or that such capacity will be available by the time a certificate of occupancy is issued. C. Applications for Type 1, 2, 3, 4 and 5 decisions involving projects which will require sanitary sewer service from the City of Tukwila shall be referred by the Department of Community Development to the Department of Public Works, which shall determine whether the City has the necessary sewer system capacity, including such mains, pump . stations and other facilities as may be necessary, to provide sanitary sewer service meeting City standards or that such capacity will be available by the time a certificate of occupancy is issued. If adequate service is not available, the Department of Public Works shall determine and shall advise the applicant of the improvements which are necessary to provide service meeting City., standards. Section 14.36.030 Mitigation A. . If water or sewer service to a project requiring such service from the City of Tukwila cannot meet City standards with existing facilities, the applicant shall be required to either: 1. complete the improvements required to provide such level of service; or 2. if the City anticipates that the improvements necessary to meet the City's water and sewer standards will be constructed within six years by a public capital facilities project, the applicant may pay a mitigation payment equal to the applicant's fair share of the cost of the improvements necessary to meet the City's water and sewer standards ; or In appropriate cases, mitigation may consist of a combination of improvements constructed by the applicant and mitigation payments. B. In the event that the applicant agrees to complete improvements pursuant to subsection A(1), the applicant shall be entitled to apply to enter into a Latecomer Agreement with the City. 5 CHAPTER 3 - TRAFFIC CONCURRENCY STANDARDS A new Chapter 9.48 is added to TMC Title 9 as follows Section 9.48.010 Determination of Traffic Concurrency Required A. No Type 1, 2, 3, 4, or 5 decision which is subject to this chapter shall be approved unless a determination is made by the appropriate Department that the standards of this chapter have been met. B. For Type 1 and 2 decisions, the Department of Community Development shall refer the application to the Department of Public Works, which shall determine whether the application complies with City standards regarding traffic concurrency and, if not, what mitigation is required. C. For Type 3, 4, and 5 decisions, the Department of Community Development shall refer the application to the Department of Public Works, which shall determine whether the application complies with City standards regarding traffic concurrency and, if not, what mitigation is required, A statement identifying the required mitigation, if any, shall be incorporated into the staff report required by TMC 18.112.020. Section 9.48.020 Exemptions This chapter shall not apply to single family building permits, multi - family building permits for projects containing four or fewer units, short plats, or any non - residential project that is categorically exempt from SEPA pursuant to TMC 21.04.080, 100, or 110. The Department shall also waive compliance with this chapter for other projects which will not generate new traffic trips. Section 9.48.030 Level of Service Standards A. Level -of- service ( "LOS ") gradations for corridors shall be measured with volume to capacity ratios graded from LOS A to LOS F, as provided in subsection B, and intersections shall be measured in average delays at intersections or average travel speeds on corridors, as determined by the Department of Public Works. 13. Volume (V) to capacity (C) ratios shall be used to quantify LOS for corridors as follows: LOS Volume /Capacity A up to 0.6 B 0.6 - 0.7 C 0.7 - 0.8 D 0.8 - 0.9 E 0.9 - 1.0 F greater than 1.0 6 Level of Service Existing Expanded ' Access A <7.5 seconds < 7.5 seconds B 7.5 - 15 seconds 7.5 - 15 seconds ' C 15.1 - 25 seconds 15.1 - 25 seconds D 25.1 - 40 seconds 25.1 - 40 seconds E 40.1 - 60 seconds 40.1 - 60 seconds F > 60 seconds 60 - 120 seconds G 120 - 180 seconds H 180 - 240 seconds I 240 - 300 seconds J >300 seconds Street Classification Principal Use Access access to abutting property Collector Arterial between access & minor Minor Arterial ' between collector & principal Principal Arterial between communities C C. The Department of Public Works may, in its discretion, utilize either a standard LOS gradation system or, in the case of intersections that are experiencing high congestion, an expanded LOS gradation system to evaluate. The LOS gradations for intersections, based on average delays are: Section 9.48.040 Arterial Classification System ... • ....• ..... A. The Tukwila Functional Arterial Classification System, which is in accord with required Federal and Washington State arterial standards, is as follows: 13. The Department of Public Works shall classify all streets in the City in accordance with the classifications in Subsection A. Such classifications shall be reviewed and modified as necessary by the Department from time to time. 7 Section 9.48.050 LOS Standards for Specific Locations A, A minimum LOS standard of E for traffic capacity shall be maintained, based upon a calculation of average LOS, for the following arterial segments: 1. E Marginal Way (S. 112th St. to North City Limit) 2, Interurban (Southcenter Blvd. to I -5) 3. Pacific Highway S. (S. 152nd St. to Boeing Access Rd.) 4. West Valley Rd (1 -405 to S. 180th St.) 5. Southcenter Parkway south of S. 180th St. B. In the Central Business District ( "CBD ") area, a minimum average LOS level of E shall be maintained. In the CBD, LOS shall be determined by using the "link" averages for the 17 segments defined in the Transportation Element of the Comprehensive Plan. For purposes of this section, the CBD is the area bounded by 1 -5, 1 -405, the Green River, and S. 180 St.) C. A minimum LOS standard of E for traffic capacity shall be maintained, based upon a calculation of LOS for individual intersections and corridor segments for all other minor, collector and principal arterials principally serving commercially zoned property. D. A minimum LOS standard of D for traffic capacity shall be maintained, based upon a calculation of LOS for individual intersections and corridor segments for all minor and collector arterials in predominantly residential areas, provided that for the following arterials, LOS shall be calculated based on the average LOS for the arterial: 42nd Ave. S., S. 160th St., S. 164th St., Macadam, S. 124th St., S. 130th St., S. 132nd St., S. 144th St., 53rd Ave. S., and 65th Ave. S. E. Access streets which exceed 1,000 vehicles per day volume will be evaluated on a case by case basis to determine whether traffic improvements or control measures are required to reduce volumes and provide adequate safety. Section 9.48.060 Design of Arterial Improvements; Load Limits A. Arterial improvements in commercial areas shall be designed to include trucking geometric and loading parameters. B, Trucking will be allowed on all arterials as well as commercial 'area access streets unless restricted by load limits. Load limits may be used as restrictions following a traffic study. Section 9.48.070 Traffic Studies & Mitigation 8 A. TMC 9.48.050 identifies Level of Service standards for specific areas and corridors that can be maintained by making improvements identified in the Transportation Element based on 2015 "build out" development traffic projections. Level of Service standards are also established for other non - specific arterials and for access streets. B. Fairshare mitigation costs /trip for the specific areas and corridors identified in TMC 9.48.050 are provided in the Transportation Element and subsequent updates of the Capital Improvement Plan. • ;. . . . • C. Any proposed project which requires a Type 1, 2, 3, 4 or 5 decision and which will generate more than five (5) or more vehicle trips in an AM, noon, or PM peak hour period shall submit, as part of the application process, a trip generation analysis using standard generation rates published by the Institute of Transportation Engineers, other standard references, or from other documented information and surveys approved by the Department of Public Works. In addition, such projects shall submit a trip distribution study, unless .the requirement for such study is waived by the Department of Public Works. D'. If the trip generation and distribution studies demonstrate that the proposed project will generate five (5) or more additional peak hour traffic trips in a specific area or corridor prior to the, horizon year established by the Transportation Element of the Comprehensive Plan established in TMC 9.48.050,.impact mitigation fees shall be paid for the rairshare mitigation costs established in the Transportation Element of the Comprehensive Plan or subsequent Capital Improvement Plan. E. If the trip generation and distribution studies demonstrate that the proposed project will generate five (5) or more additional peak hour traffic trips on any non - specific arterial or access street such that the intersection, corridor, or area will be below the Level of Service standards established in TMC 9.48.050, prior to the horizon year established by the Transportation Element of the Comprehensive Plan, the Director of the Department of Public Works shall require, as appropriate to the particular circumstances, one of the following methods for mitigation of the project's traffic impacts: 1. Require the applicant to pay a mitigation payment equal to the applicant's proportionate fair share of the cost of the improvements necessary to restore the intersection(s) arterial(s) or access street(s) to (1) the level of service chat would exist at the time the project is completed, but without project traffic, or (2) the level of service standard established in TMC 9.48.050; or 2. Require the applicant to complete the improvements required to restore the intersection(s) arterial(s) or access street(s) to (1) the level of service that would exist at the time the project is completed, but without project traffic, or (2) the level of service standard established in TMC 9.48.050; or 3. In appropriate cases, mitigation may consist of a combination of improvements constructed by the applicant and mitigation payments. If the proposed project does not generate five (5) or more additional peak hour traffic trips at an intersection or corridor.which will be below the Level of Service standards established in TMC 9.48.050 prior to the horizon year for the Transportation Element of the Comprehensive Plan, no mitigation under this section will be required. F. A project applicant shall have the right to mitigate all or a portion of the capacity impacts of a project by . utilizing capacity mitigation measures, including but not limited to, carpooling and rideshare programs, widenings (roadway, lane, radius), signal improvements, and other capacity improvements. In the event that mitigation measures such as carpooling and rideshare programs are proposed, the applicant shall execute such agreements with the City as are necessary to assure the permanent availability of such programs. G. In the event that the applicant completes improvements which are part of the Circulation System adopted in the Comprehensive Plan and the cost of such improvements exceeds the applicant's proportionate fair share of the cost of such improvements, the applicant shall be entitled to apply to enter into a Latecomer Agreement with the City. Section 9.48.080 Mitigation of Traffic Safety Hazards H. The Mitigation Payment Schedule for the Transportation Element of the Comprehensive Plan shall be updated every three years or with the annual Capital Improvement Plan update. A. If the Department of Public Works determines that a hazard to safety could reasonably exist as a result of traffic generated by a project, the applicant shall be required to construct the improvements necessary to mitigate the traffic safety hazard regardless of whether the roadway corridor or intersection meets the capacity standards of this chapter. B. If the Department of Public Works determines that there is an existing hazard to safety affecting a traffic corridor or intersection which will be impacted by traffic from a proposed project and that the improvements necessary to resolve the safety hazard are not a funded project in the Capital Improvement Program and are not already funded for correction from other sources, the applicant shall have the option of (1) constructing the improvements necessary to mitigate the traffic safety hazard, subject to the right to apply to enter into a Latecomer Agreement regarding such project, or (2) postponing the project until such time as a project to correct the safety hazard has been fully funded. CHAPTER 4 - ADDITIONAL STANDARDS FOR UNCLASSIFIED USES A new section TMC 18.66.110 is added to TMC ch. 18.66 as follows: Section 18.66.110 Normal upkeep, repairs, and maintenance; replacement of existing structures Normal upkeep, repairs, maintenance, strengthening, or restoration to a safe condition of any building or structure being used as part of an unclassified use shall not require a new or revised unclassified use permit. The replacement of existing structures with either new structures of equivalent size and/or capacity, or with new structures which do not change the use and do not constitute an expansion or enlargement as described below, shall not require a new or revised unclassified use permit; provided that, in any event, any structure that is non - conforming by reason of its height, bulk, or setbacks shall not be re- constructed in a manner which increases the extent of the nonconformity. Nothing in this section shall modify applicable requirements that such construction work may require a building permit or other construction permits pursuant to TMC ch. 16 (construction codes). A new section 18.66.120 is added to TMC ch. 18.66 as follows: Section 18.66.120 Expansion of Existing Unclassified Use - Animal Rendering Facilities In addition to the structures permitted pursuant to TMC 18.66.110, existing animal rendering facilities shall be allowed to construct new facilities to update and/or modernize such use without needing to obtain a new :or revised unclassified use permit if such construction involves an intensification of the permitted existing facility. For purposes of this section, "facilities" shall refer to all structures, including tanks, processing equipment, buildings and other improvements used in the rendering operation, and "intensification" shall mean new construction shall meet all of the requirements below. Any proposed new construction which fails to meet one or more of the requirements of intensification shall be considered an enlargement or expansion, and shall require an application for a new or revised unclassified use permit for the facilities which constitute the enlargement or expansion: A. The construction of new facilities shall be considered an intensification and may be permitted without the need to obtain an Unclassified Use Permit (UUP) if: 1. The total area of the site is not increased. 10 2. The construction of new facilities does not generate more than ten new vehicle trips at' peak hour, as determined pursuant to TMC ch. 9.48, related to traffic concurrency. 3. No new facilities are located in the River Environment or Low Impact portion of the Shoreline. 4. The new facilities will comply with the performance standards set forth in TMC 18.66.130. 5. The construction of new manufacturing facilities does not result in more than a 5% cumulative increase in the manufacturing capacity of the processing facility. 6. The construction will not increase the extent of any nonconformity of any' structure by reason of its height, bulk or setbacks. B. Any proposed new facility which does not meet criteria Al through A6, above, hall be considered an enlargement or expansion, and shall comply with the provisions of TMC Ch, 18.66, Unclassified Use Permits. C. Whether or not a proposed new facility is considered an intensification or an expansion/enlargement, all other applicable codes such as construction codes, SEPA, etc., shall continue to apply. A new section TMC 18.66.130 is added to TMC ch. 18.66 as follows: Section TMC 18.66.130 Performance Standards for Rendering Plants The following performance standards shall apply to rendering plants, in addition to the performance standards for the applicable zoning district.: A. Any new facilities constructed at a rendering plant which will be used for storage or transmission of liquid or semi - liquid products will be protected by containment facilities capable of preventing the release of any product into surface or ground waters in the event of a spill or breakage. If more than one storage or transmission facility is protected by a containment facility, such containment facility shall be of sufficient size to contain a spill of the largest storage or transmission facility so protected. B. Any new facilities will utilize the best feasible odor abatement control equipment and shall be designed, constructed and operated so that the new facilities will not increase the risk of odor emissions from the site. C. The facility, including both existing and new facilities, shall comply with applicable air pollution control requirements of the Puget Sound Air Pollution Control Agency, including both procedural and substantive standards. . D. A copy of the current Spill Prevention Control and Countermeasure Plan (SPCCP) for the new facilities required by the Puget Sound Air Pollution Control Agency shall be on file with the DCD. TMC 18.70.100 and Ordinance 1758, §1(part) are amended as follows: . Section 18.70.100 Conditional and Unclassified Uses .--,•-••*^... A legal use does not become nonconforming because the zone in which it is located is changed to a zone which requires a conditional or unclassified use permit for the use, or because the use is changed from an allowed use to a conditional or unclassified use within the same zone; provided, however, the use may not be allowed or buildings may not be enlarged without first obtaining a conditional or unclassified use permit if required pursuant to requirements of TMC ch. 1 8.64 or TMC ch. 18.66. the Gonda ienal e-ge vies- chapter- ef4his title. CHAPTER 5 - MISCELLANEOUS Section 501 Severability Should any section, subsection, paragraph, sentence, clause or phrase of this ordinance be declared unconstitutional or invalid for any reason, such decisions shall not affect the validity of the remaining portion of this ordinance. Section 502 Effective date ' This ordinance shall apply to all land use permit applications filed on and after April 1, 1996, except applications for road vacations, landmark designations, and approvals related to the use of public areas or facilities. PASSED BY THE CITY COUNCIL OF HE TTY OF TUKWILA, WASHINGTON, at a Regular Meeting thereof this / day of , 1996. ATTEST /AUTHENTICATED ,. w lane E. Cantu ty Clerk APPRO D AS TO FORM: Of ►�e of the City A WO FILED WITH THE CITY CLERK: - 9 q PASSED BY THE CITY COUNCIL: 9— /-- ?t. PUBLISHED: 7-. 6— 9 EFFECTIVE DATE: April 1, 1996 ORDINANCE NO.: 74 John W. R ts, Mayor 12 1, ) CITY OF TUKWILA SUMMARY OF ORDINANCE NO. / 9 AN ORDINANCE OF THE CITY OF TUKWILA, WASHINGTON, IMPLEMENTING THE LAND USE PERMIT CONSISTENCY AND CONCURRENCY REQUIREMENTS OF RCW 3H. 36.70A, ADDING NEW CHAPTERS TO TITLES 9, 14 AND 18 OF THE TUKWILA MUNICIPAL CODE, AMENDING CHAPTERS 18.66 AND 18.70 OF THE TUKWILA MUNICIPAL CODE, REQUIRING A DETERMINATION OF CONSISTENCY WITH ADOPTED PLANS, LAWS AND POLICIES FOR ALL PERMIT APPLICATIONS, , ESTABLISHING PROCEDURES TO DETERMINE WHETHER ADEQUATE UTILITY AND TRANSPORTATION FACILITIES ARE AVAILABLE TO SERVE NEW DEVELOPMENT, AUTHORIZING THE IMPOSITION OF MITIQATION CONDITIONS, AMENDING STANDARDS FOR THE REVIEW AND APPROVAL OF SHORELINE SUBSTANTIAL DEVELOPMENT PERMITS, SUBDIVISIONS, AND ADOPTING STANDARDS FOR THE EXPANSION AND ENLARGEMENT OF CERTAIN UNCLASSIFIED USES. On f f f , the City Council of the City of Tukwila passed Ordinance No. )7Z, , i plementing the concurrency requirements of RCW 30.70A. The full text of this ordinance will be mailed without charge to anyone who submits a written request to the City Clerk of the City of Tukwila for a copy of the text. • APPROVED by. the City Council at its meeting of Published Seattle Times: .. . -.... .. Po - Jane E. Cant 1 ity Clerk /79'4 ..r SCALE: 1 -1/2" = 1' -0" n I I 12" O.C., TYP. DRILL EXISTING SLAB, EMBED 6" MIN. (TYP) RE -POUR 6" CONC. OVER COMPACTED BASE WIRE TIES '4 REINFORCED ROD .12" O.C. EA. WAY LAP MIN 6" EDGE OF CONCRETE CUT NOTE: APPLICABLE TO ALL FLOOR AREAS PENETRATED FOR PLUMBING LINE REPAIR. TYPICAL STRUCTURAL SLAB REPAIR Space Heat Type 0 Electric resistance ig( All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Area if they are insulated to the level reqruired d for opaque ue walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing I I R • A (� P _ 51 n• � X 1 00 = Z . +_ ! v"S Concrete/Masonry Option 0 yes Check here if using this option and if project meets all requirements for the ConcretelMasonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying g no assembly below. Envelope Requirements (enter values as applicable) Fully heated /cooled space Minimum Insulation R- values Roofs Over Attic For Building Department Use - 50 All Other Roofs Applicant Address: 1&00 1544 ii,. i4e. 3 yrV., 1C0 eloF J iboos Applicant Phone: ( 5)71}- 7.g)`r7 Opaque Walls g- - I _I Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade g Radiant Floors Maximum U- factors Opaque Doors , 6 Vertical Glazing -(QO Overhead. Glazing Maximum SHGC (or SC) Vertical /Overhead Glazing I I. 0 Project Info Project Address 1155 0 11'1' 1 fle_ v� 1 Date I 001 /GM; 1 I' -\ /IJ-, 7 *A q'�) f.� For Building Department Use Applicant Name: gjG'k Vv Applicant Address: 1&00 1544 ii,. i4e. 3 yrV., 1C0 eloF J iboos Applicant Phone: ( 5)71}- 7.g)`r7 Envelope Summa Climate Zo e 1 ENV -SUM 1994 Washington State Nonresidential Energy Code Compliance Forms Project Description ❑ New Building ®,Addition ❑ Alteration ❑ Change of Use Compliance Option IR Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ ENVSTD O Systems Analysis Seml- heated space' Roofs Over Semi - Heated Spaces' Minimum Insulation R- values 'Refer to Section 1310 for qualifications and requirements Notes: Opaque Concrete /Masonry Wall Requirements Insulation on interior - maximum U- factor is 0.19 Insulation on exterior or integral - maximum U- factor is 0.25 If project qualifies for Concrete /Masonry Option, list walls with HC >_ 9.0 Btulft'• °F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 20 -5b in the Code. Wall Description (including insulation R -value & position) U- factor Dqe -o351• RECEIVED CITY OF TUKWILA OCT 2 1998 PERMIT CENTER June, 1995 1 Building Permit Plans Checklist ENV -CHK 1994 Washington State Energy Code Compliance Forms June, 1995 Project Address I7a55 4001 K� � ir 1 �u , � � qd Igsate I f1, /Y1' loft _I The following information is necessary to check ,a building permit application for compliance with the building envelope requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component { `Location Information Required I on Plans I Building Department Notes GENERAL REQUIREMENTS (Sections 1301 -1314) 1301 Scope Unconditioned spaces identified on plans if allowed 1302 Space heal type: a I n - If "Other", indicate on plans that electric resistance heal is not allowed 1310.2 Semi - heated spaces Semi - heated spaces identified on plans if allowed 1311 Insulation 1311.1 Insul. installation Indicate densities and clearances Y 0i- �? 1311.2 Roof /ceiling insul. Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced baits x � A j YES 1311.3 Wall insulation Indicate R -value on wall sections; Indicate face stapling of faced baits; Indicate above grade exterior insulation is protected; Indicate loose -fill core insulation for masonry walls as necess; Indicate heat capacity of masonry walls if masonry option is used or if credit taken in ENVSTD; � y C 1311.4 Floor insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents N i 1311.5 Slab -on -grade floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 24" from top; Indicate above grade exterior insulation is protected 1311.6 Radiant floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; Indicate insulation also under entire slab where req'd. by Official . 1312 Glazing and doors Provide calculation of glazing area (including both vertical vertical and overhead) as percent of gross wall area ��f ‘r9 1312.1 U- factors Indicate glazing and door U- factors on glazing and door Indicate (provide area - weighted calculations as necessary); Indicate if values are NFRC or default, if values are default then specify frame type, glazing layers, gapwidth, low -e coatings, gas fillings —I • Y 5 1312.2 SHGC & SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area - weighted calculations as necessary) A -I 1313 . Moisture control ! � 1313.1 Vapor retarders Indicate vapor retarders on warm side A- .( 1313.2 11 Roof /ceiling vap.ret. Indicate vapor retarder on roof section; Indicate yap, retard. with sealed seams for non -wood strut. /( / ��' 5 ] e 1313.3 Wall vapor retarder Indicate vapor retarder on wall section �3 1313.4 Floor vapor retarder Indicate vapor retarder on floor section 1313.5 Crawl space yap. ref. Indicate six mil black polyethylene overlapped 12" on ground 1314 Air leakage 1314.1 Bldg. envoi. sealing Indicate sealing, caulking, gasketing, and weatherstripping Al2 1314.2 Glazing /door sealing Indicate weatherstripping A-0 1314.3 Assemb. as ducts Indicate sealing, caulking and gaskeling PRESCRIPTIVE /COMPONENT PERFORMANCE (Sections 1320 -23 or 1330 -34) Envelope Sum. Form Completed and attached. Provide component performance worksheet if necessary Provide ENVSTD screen 1 output if necessary If "no" Is shown for any question, provide explanation: 1994 Washington State Nonre" 1ential Energy Code Compliance Form Lighting Permit Plans Checklist 1994 Washington State Energy Code Complance Fora LTG -CHK June, 1995 Project Address t7E5 J t., )0114. 43-'' _ ?pa ... r 04 9Sl Sti Date le 7'C 15 'I The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) 1513.1 Local control/access Schedule with type, indicate locations A,,'I -' 1513.2 Area controls Maximum limit per switch At—I " 1513.3 Daylight zone control Schedule with type and features, indicate locations S,,S vertical glazing Indicate vertical glazing on plans ilcI 14. ik• overhead glazing Indicate overhead glazing on plans /4 A • 1513.4 Display /exhib/special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (5' (a) timer w/backup Indicate location • .► 3 4 ,A. (b) photocell. Indicate location -/-.I. A 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto, switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans �sS Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency If "no" is circled for any question, provide explanation: 1994 Washington State Nonrejdential Energy Code Compliance Form Z. Project Info Project Address 17555 500 -1T fie-W Date It, o % '` /cis GJ TO J i. ? VI � qS 10. For Building Department Use Covered Parking Applicant Name: F.-i4 . 4417.. Applicant Address :IVOO fPdM 'tg∎ 1-0.7 *M. UV, eal,OVM,VOC cel0 Applicant Phone: ('j5) 7y -31'17 Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft2 Allowed x Area Covered Parking PIi■l. r+- I 5z5. y- 5z5. 4-- Open Parking x/051 i t afi 14.5 53.52. Outdoor Areas IM-- ' D �-1 I LIGHT' 2 1p 7. 1 1 n/ Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking G- FA1- 1.17x.1.- (0- 1 3Z(:2 3 fJ Open Parking C r I Ill 12 Outdoor Areas IM-- ' D �-1 I LIGHT' 2 1p Location Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) Covered Parking 0.2 W/ft Open Parking 0.2 W/f1 Outdoor Areas .141.\4-1 MI) t2 0.2 W/ft 7 Z 7. 1 1 n/ Bldg. (by facade) 0.25 W/ft Bldg. (by perim) 7.5 W/lf W 4 Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed iJ vi pT o WAPOI4t i-11'� .teat/ - i 1.16014--r ' I �t� ---. 6w 2 ii 130 Lighting Summary LTG -SUM 1994 Washington State Nonresidential Energy Code Compliance Forma Project Description Alteration Exceptions (check appropriate box) 1994 Washington State Nonre ❑ New Building ❑ Addition ❑ No changes are being made to the lighting Maximum Allowed Lighting Wattage (Interior) ❑ Alteration Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) ❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1 f �j, Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Total Proposed Watts may not exceed Total Allowed Watts for Interior Maximum Allowed Lighting Wattage (Exterior) Note: for building exterior, choose either the facade area or the perimeter method, but not hot Proposed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior)• Total Proposed Watts may not exceed Total Allowed Watts for Exterior ntial Energy Code Compliance Form Total Proposed Watts June. 1995 otalAllowe a otat Proposed Watts Lighting Summary LTG -SUM 1994 Washington State Nonresidential Energy Code Compliance Forma Project Description Alteration Exceptions (check appropriate box) 1994 Washington State Nonre ❑ New Building ❑ Addition ❑ No changes are being made to the lighting Maximum Allowed Lighting Wattage (Interior) ❑ Alteration Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) ❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1 f �j, Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Total Proposed Watts may not exceed Total Allowed Watts for Interior Maximum Allowed Lighting Wattage (Exterior) Note: for building exterior, choose either the facade area or the perimeter method, but not hot Proposed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior)• Total Proposed Watts may not exceed Total Allowed Watts for Exterior ntial Energy Code Compliance Form Total Proposed Watts June. 1995 otalAllowe a otat Proposed Watts Mr. Rick Lentz Merrick Lentz Architects 1800 - 136th Place N.E., Bellevue, WA 98005 Re: Suite 100 Azteca Restaurant Expansion Program City Project File D98 -0354 Trip Generation & Distribution Christopher brown Cn Associates 9688 12ainier Ave. 8. Seattle, WA 98118 -5981 (206) 722 -1910 Fax (206) 722 -1909 December 30, 1998 Dear Mr. Lentz Per the City of Tukwila's memorandum dated December 9th, under Item 4, we are providing the following trip generation for the . additional seating capacity of the Azteca Restaurant. In addition, the trip distribution is also appended in terms of . the percentage of site generated traffic and, likewise, the noon and p.m. peak hour traffic assignment. The following table describes the trip generation for the "before case ", namely as now built and the "after case" which is with the.additional 28 seats. TABLE I Azteca Restaurant Total Trip Generation: "Before" versus "After" Before After AWDT 1,340 1,439 veh. /day Noon inbound 57 68 veh. /hour Noon outbound 53 57 veh. /hour Combined noon hour traffic 110 125 veh. /hour p.m. inbound 66 73 veh: /hour p.m. outbound 47 52 veh. /hour Combined p.m. traffic 113 125 veh. /hour Traffic Engineers CAS Transportation Planners CITY OF TQKWIIA JAN 0 PuriMrT CENTER rO �'�'' Mr. Rick Lentz December 30, 1998 page 2 It is my understanding that the restaurant is not open for the morning breakfast interval and so the a.m. peak hour is not included in the above table. If, on the other hand, the a.m. peak hour is to be served, and in this case please understand it is for the a.m. peak of the street or the 7:00 -9:00 interval, then its trip generation would be as shown below in Table II. TABLE II Azteca Restaurant A.M. Total Trip Generation: "Before" versus "After" Before . After a.m. inbound 66 73 veh. /hour a.m. outbound 61 .67.veh. /hour Combined a.m. traffic 127 140 veh. /hour Since the possible mitigation fees are based on the change or added traffic from the restaurant expansion, the data of Table III is used. This data is replicated on the appended traffic assignments of Figures 2 and 3. TABLE III Azteca Restaurant New Traffic Added the Network Time Interval Volume a.m. peak hour noon peak hour p.m. peak hour 13 veh. /hour • 15 veh. /hour 12 veh. /hour Please note that the added trips are based, on the internal seating capacity increase and not on the new patio dining. This is because no patio dining takes.place until the summer and, even then, is a table- for - table exchange according to our sources. Mr. Rick Lentz ... December 30, 1998 page 3 Last, as you will see form the trip assignment figures (2 and 3) no intersection has an hourly volume increase above the common threshold of 10-trips per hour. Accordingly, we have not computed changes in Levels of Service at the intersections shown on Figures 1 through 3. I trust you will find the above useful in your deliberations: If you have any questions, please feel free to.call. Yours truly, encl. cvb/s p.s. I am also including a print of, the Parkway ,Supercenter plan since it also notes the location of the. Azteca , Restaurant. Trip generation data is also provided as, referende material. . , Strander Boulevard FIGURE 1 Klickitat Drive Site Trips in Percent Christopher Brown CK Associate& 9688 1ainier Ave. 8. (Seattle, WA 98118 -5981 (206) 7224910 Fax (206) 7224910 Klickitat Drive FIGURE 2 Noon Peak Hour Trip Assignment • Strander Boulevard . 180th Street Christopher Brown of Associates 9688 Painier Ave, 8, (Seattle, ' WA 98118.5981 (206) 722 -1910 Fax (206) 722 -1910 . :Strander Boulevard 180th-Street Christopher 6rovn U Associates 9688 rainier Ave. 8, (Seattle, WA 98118 -5981 (206) 722 -1910 Fax (206) 722.1910 FIGURE 3 P.M. Paek Hour Trip Assignment Klickitat Drive • Note: The restaurant is not , open ,for the morning .peak hour. .The A.M. peak hour trip assignment is 4P• v - 1N\1YJA\1 4 rA411 \ \Yr'.� ,rrr.lr: rremwer:.■• e TTiTTm) 114111M " a ORIIHHlIID al1HHHH0m �? aCfffHI0fI1HHH� ' flltl3, 41111101NIK : V'1 L4 HIIOIHHI01IH4J a QHlI0fHH1011HIf1 �t4fHI01HHf01IIHf01� aOIHIOI11III0IHH115 �fllflllllllflllllll� a0111I01N101H1110 a11111IOII411I11111HI0 iM101111iI0610 441I0I141I011H110 ,`..1..+� 41= .011MI0IIII11O11H14IO 414}11+H1H aO 11HH O HlH I0 }HH 10.0 1110 1IHHIOIIIHI0I11Nf0 11110 411 ti jmmi.111 11 (1111(6 1(II1IuIIIIIIITIIIUEllllll] I(IIIIIII➢IIIIIIUIIIIR . 01IIIHIOIHHIOIHHIO .OHIHION11o111O 'O1IHHI01IHHO1HHI01 IIIHIOIHHi0IH0 IIiiii111I 1 ,41111111111lllinluO (1111111111 • antill J W U CC a. _1 III- � , I � r 8 4 , e J k .1 ¢ g w a . a 7 t EL fi CC cn a� .. c Q 33 E 000 GE s L• o MT H an • T1 Trip Generation per Seat Data Plot and Equation Trip Generation, 6th Edition High Turnover (Sit -Down) ict staurant (832) Average Vehicle Trip Ends vs: Seats On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a.m. Number of Studies: 10 Average Number of Seats: 150 Directional Distribution: 52% entering, 48% exiting Average Rate Range of Rates Standard Deviation 0.47 0.30 - 0.76 0.70 130 120 110 100 90 80 ; 70 60 X 50 • 40 —x 30 i Fitted Curve Equation: Not given X Y �- x X X I 100 110 120 130 140 150 160 170 180 190 200 X = Number of Seats X Actual Data Points Average Rate R2 = •••• X 1386 Institute of Transportation Engineers High - Turnover (Sit -Down) Restaurant (832) Trip Generation per Seat Number of Studies: 14 Average Number of Seats: 145 Directional Distribution: 58% entering, 42% exiting Average Vehicle Trip Ends vs: Seats On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. Average Rate Range of Rates Standard Deviation 0.42 0.14 - 1.73 0.75 Data Plot and Equation 160 150 140 130 120 110 100 90 80 — 70 60 — 60 "' 40 30 20 10 X Actual Data Points X X K Fitted Curve Equation: Not given X X X X :. I I X = Number of Seats X X • I F 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 Average Rate R2 ...• Trip Generation, 6th Edition 1387 institute of Transportation Engineers Trip Generation per Seat Data Plot and Equation Trip Generation, 6th Edition High- Turnover (Sit -Down) Restaurant (832) Average Vehicle Trip Ends vs: Seats On a: Weekday Number of Studies: 2 Average Number of Seats: 125 Directional Distribution: 50% entering, 50% exiting Average Rate Range of Rates Standard Deviation 4.83 4.37 - 5.49 Caution - Use Carefully - Small Sample Size 100 X Actual Data Points Fitted Curve Equation: Not given 110 120 X = Number of Seats 130 140 Average Rate H2 = .... 150 1385 Institute of Transportation Engineers Additional Data Land Use: 832 High- Turnover (Sit -Down) Restaurant Description This and use consists of sit -down eating establishments with turnover rates of approximately one hour or less. This type of restaurant is usually moderately priced and frequently belongs to a restaurant chain. Generally, these restaurants serve lunch and dinner; they may also be open for breakfast and are sometimes open 24 hours per day. Some facilities contained within this land use may also contain a bar area for serving food and alcoholic drinks. Quality restaurant (land use 831), fast -food restaurant without drive - through window (land use 833), fast -food restaurant with drive - through window (land use 834), fast -food restaurant with drive - through window and no indoor seating (land use 835), and drinking place (land use 836) are related uses. Vehicle occupancy ranged from 1.39 to 1.69 persons per automobile on an average weekday. The average for the sites that were surveyed was approximately 1.52. A significant number of the studies in this land use were conducted prior to 1980. A study was conducted to test the sensitivity of the older versus newer data. It was determined that there is no statistically significant difference between the pre- and post -1980 data, therefore, all of the data . points were retained to maximize the size of the data base. Users should exercise caution when applying statistics during the A.M. peak period as the sites contained in the data base for this land use may or may not be open for breakfast. The sites were surveyed from the 1960s to the 1990s throughout the United States. Source Numbers 2, 4, 5, 72, 90000, 126, 269, 275, 280, 300, 301, 305, 338, 340, 341, 358, 384, 424, 432, 437, 438, 444 Trip Generation, 6th Edition 1375 Institute of Transportation Engineers 01/04/99 11:12 206 772 4321 f • JA 04 '99 10:50 BROId ASSOCIATES • Dear Mr. Lentz: •Thank you for providing me with a copy of the city's Transport ;tion E].yment, Table '12, MI.ti,gation proportionate Fa.rahare Costs attendant to the above restaurant. 1 have taken the trip data provided to you by my letter dated December 30, 1998 and, with than data, derived the following costs for Azteca Restaurant expansion program. These costs are as follows. Christopher Drown IC Associates 9688 Rainier Ave. 8. (Seattle, WA 981184981 206 222-1910 hut. s - 7224909 Mr. .Rick Lentz Merrick Lentz Architects 1800 - 136th Place N.E., Bellevue, WA 98005 Re: Suite 100 Azteca Restaurant Expansion Program City Project File D98 -0304 • Trip Generation & Distribution Traffic Mitigation Fair Share Cost Estimate Aztec4,Rutaprant Traffic Mitigation' Fair Share Cost Estimate Intersection or Link S. Center /Strander Andover E. /Strander Andover W• /Strander S 180th /SR 181 Andover E. /Baker Andover W. /Minkler S. Center /168th W. Valley / Strander Interurban Br. Mi 1 Widen WALT $ 140 Widen NSLT $ 135 Widen NSLT $ 317 Widen NS /LAW $ 476 Signal NSLT $ 377 Signal NSLT $ 377 January 4, 1999 Cost /Trip Trips Signal $ 167 9 $1,503 Widen :2 -LT $ 283 3 $ 849 Widen 2 -LT $1,122 0 0 Grand Total, Mitigation Fees $8,101 Traffic Eksinecrr Cpl Transportation Planners P.1 CHRISTOPHER BROWN, P.E. FAX: (206) 722 -1909 PH: (206) 722 -1910 70: FAX* C" .: PAGES, _- .DATL Cost 9 $1,260 3 $ 405 3 $ 951 4 $1,900 0 $ 0 0 $ 0 ,, JAN 04 '99 10:50 BROWN &ASSOCIATES. Mr, Rick Lentz January 4, 1999 page 2 From the attached table by the city DPw you will see other projects in the post 6 -year interval. Only one has a per trip fee but there are no site related trips and so this project is not shown in the above table. The other post 6 -year projects do not have per trip fee estimates and so are not shown, either. I trust you will find the traffic mitigation fairshare estimates adequate for your project submittal. r - B rown .,. " :' " Yours truly, P.2 - -- " ° JAN 04 '99 10:51 BROWN &ASSOCIATES : ,(, ‘4•4‘_ rvtcta Ns and e/w :. ' . - �ti• '�; Andover Pk EfB ter , signal , - { ;Andover Pk W/Mi kler n/s lefts signal Southcenter PkWy /168 . ;' ' , • • •• W Valley /Strander NB dual left turn lanes Interurban Bridge widen for dual lefts , • • signal his i a "filnit level" estimate. .c r :s e -- Wit N, I. u ure (Beyo d 6 yea Minkler (APW , Southcenter PkWy) construct 31ane street S 178 St (Southcenter pkwy -WC'L) real3� (cap /safety /transit) Andover PkWy (T PkWy -1130) widen to 5 lanes ' Andover Pk E (T PkWy -180) widen to 5 lanes 4 intsr Southeenter PkWy (180-200) ' construct 3 and 5 lane street . November 1993 or Link Pk Vol Plc Vol 3,899 4,853 3,211 3,905 694 S94,000 $135 5 3,082 4,016 934 5296,000 5317 5,236 7,760 2,524 51,200,000 5475 790 1,453 . 663 5250,000* . 2,441 3,078 637 . S250,000* 5392 2,425 3,324 3,433 4,316 899 2,831 3,945 ,57 .3 9 ' 47 . • 0 1,015 1,015 •789 1,424 635 1,112 • 1,833 721 970 1,420 450 408, 1,600 1,192 DiPf Cost 954 $134,000 50 dIA 1,114 51,250,000* 1214 z 671- , 3bfl l 2 f P'D ;,f/e r' Cost/ Trig 5140 7 5377 0 O 883 S250,000* 5233 S 51.122 tle°7 1z 3,9 6 c 71 ell 0* To: Kelcie Peterson, Permit Coordinator From: Gary Barnett, Public Works Re: Azteca Restaurant traffic mitigation fe (permit D98-0354) Date: 1.8.99 Please collect $8101.00 from the applicant when the building permit is issued. These traffic mitigation fees are based upon the city's concurrency ordinance. The fee amounts are as specified by the applicant's traffic engineer in letter dated 12.30.98 from Chris Brown to Rick Lentz. Public Works concurs with the calculation results. TO: FROM: DATE: SUBJECT: c City of Tukwila Public Works Engineering January 7, 1999 AZTECA Restaurant 17555 Southcenter Pkwy Project Number: P98 -0059 Permit Number: D98 -0354 Contact Person: Rick Lentz Phone: (425)747 -7177 Department of Public Works NOTIFICATION OF UTILITY PERMIT ACTION Permit Center John W. Rants, Mayor Ross A. Earnst, P. E., Director THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON JANUARY 7, 1999: Storm Drainage PERMIT FEE 25.00 TOTAL: $ 25.00 Two copies of the confirmed Utility Permit Application and plans are attached for inclusion in the permit file. JJS /jjs CF: Development File (with copy of application and plans). PW Utilities Inspector (with copy of application and plans) Finance Dept. (with copy of application) 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 • Fax (206) 4313665 January 4, 1999 Joanna Spencer Department of Public Works City of Tukwila 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington (98188) RE: Plan Review #D98 -0354 Dear Ms. Spencer: MERRICK LENTZ ARC ECT Per your plan review comment letter dated December 9, 1998 (received by us via fax on December 21), the following is submitted to address the comments. The numbers refer to your letter of December 9, copy attached. 1. There are no existing utility lines in the area of the proposed building addition. 2. After further review, there will be no need to add new downspouts to the building. The new roof will be sloped to drain to the existing downspouts on the lower roof section immediately adjacent to the proposed addition. 3. This comment does not identify the pole in question. Azteca has no knowledge of the problem referrenced by this item. Azteca has done no sitework construction in recent years. Since the construction work around the Azteca site was recently completed by others, those are the people that should be contacted about any corrective action needed. 4. A traffic study has been prepared to address the comments of this item. A mitigation fee is proposed. 5. There are no civil engineering drawings included with this proposal. All plans are stamped and signed by the architect of record. RECEIVED CITY OF TUKWILA JAN 9 4 1998 PERMIT CENTER 1800 - 136th Place N.E., Suite 100 Bellevue, Washington 98005 425/747 -3177 • FAX 425/747 -7149 E -Mail mlarchitect @isomedia.com Page Two Department of Public Works January 4, 1999 Sincerely, MERRICK LENTZ ARCHITECT Merrick D. Lentz Principle Architect The contractor had hoped to begin construction on this project on January 4. If there is any to expedite this review it would be appreciated: Thank you for your help - - JAN 04 '99 10:50 BROWN &ASSOCIATES. Christopher Brown CS Associates 9688 Rainier Ave. 8. Beattie, WA 98118.3981 206 722 -1910 flax . s - 722-1909 Mr. .Rick Lentz Merrick Lentz Architects 1800 - 136th Place N.E., Bellevue, WA 98005 Re: Aztecs Restaurant Expansion Program City Project File D98 -0354 . • Trip Generation & Distribution Traffic Mitigation Fair Share Cost Estimate Dear Mr. Lentz: C Intersection or Link ' S. Center /Strander Andover E. /Strander Andover W. /Strander S 180th /SR 181 Andover E. /Baker Andover W. /Minkler S. Center /168th W. Valley /Strander Interurban Br. r Mi,kl Suite 100 Grand Total, Mitigation Fees Widen WALT $ 140 Widen NSLT $ 135 Widen NSLT $ 317 Widen NS /EW $ 476 Signal NSLT $ 377 Signal NSLT $ 377 Signal $ 167 Widen;2 -LT $ 283 Widen 2 -LT $1,122 U 13 January 4, 1999 Traffic En8inecrs a Transportation Planners CHRISTOPHER BROWN, P.E. FAX: (206) 722 -1909 PH: (206) 722-1910 TO: FAX# PAGES - 5:7 DAM L .l.L Thank you for providing me with a copy of the city's T ;ansportation Elsment, Table • 12, Mitg atiQ0 Proportionate Ta,irsh attendant to the above restaurant. Azteca Restaurant Traffic Mitigation' Fair Share Cost Estimate I have taken the trip data provided to you by my letter dated December 30, 1998 and, with that data, derived the following costs for Azteca Restaurant expansion program. These costs are as follows. Cost /Trip Trips Cost 9 $1,260 3 $ 405 3 $ 951 4 $1,900 0 $ :0 0 $ 0 9 $1,503 3 $ 849 0 0 9 1 2 $8,101 P.1 Mr. Rick Lentz Merrick Lentz Architects 1800 - 136th Place N.E., Suite 100 Bellevue, WA 98005 Dear Mr. Lentz: Christopher Brown Cn Associates 9688 Rainier Ave. o. (kettle, WA 98118 -5981 (206) 722 -1910 Fax (206) 722 -1909 December 30, 1998 .1 /4/91 Re: Azteca Restaurant - Expansion Program City Project File D98 -0354 Trip Generation & Distribution 1 0/d $ 11.4 Per the City of Tukwila's memorandum dated December 9th, under Item 4, we are providing the following trip generation for the additional seating capacity of the Azteca Restaurant. In addition, the trip distribution is also appended in terms of the percentage of site generated traffic and, likewise, the noon and p.m. peak hour traffic assignment. The following table describes the trip generation for the "before case ", namely as now built and the "after case" which is with the additional 28 seats. TABLE I Azteca Restaurant Total Trip Generation: "Before" versus "After ". Before After AWDT 1,340 1,439 veh. /day Noon inbound 57 68 veh. /hour Noon outbound 53 57 veh. /hour Combined noon hour traffic 110 125 veh. /hour p.m. inbound p.m. outbound Combined p.m. traffic Traffic Engineers C4 Transportation Planners 66 73 veh. /hour 47 52 veh. /hour. 113 125 veh. /hour RECENED OITY OF TUKWILA JAN 0 4 1998 P RM17 CENTER OCt11-0354fg December 18, 1998 Dear Mr. Lentz: City of Tukwila Department of Community Development Steve Lancaster, Director Rick Lentz 1800 - 136th Place NE, Suite 100 Bellevue, WA 98005 SUBJECT: CORRECTION LETTER #1 Development Permit Application Number D98 -0354 Azteca Mexican Restaurant 17555 Southcenter Py John W. Rants, Mayor This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Public Works Department. At this time the Building Division, Fire Department and Planning Division have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your review does not require revised plans but requires additional reports or other documentation, please submit four (4) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431- 3671. Sincerely, zwriazA. ich_er Brenda Holt Permit Technician Enclosures File; D98 -0354 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 41313670 • Fax (206) 431.3665 City of Tukwila John W. Rants, Mayor Department of Public Works Ross A. Eamst, P. E., Director PUBLIC WORKS DEPARTMENT COMMENTS DATE: December 9, 1998 PROJECT NAME: Azteca Mexican Restaurant PERMIT NUMBER: D98 -0354 PLAN REVIEWER: Contact Joanna Spencer at (206) 433 -0179 if you have any questions regarding the following comments. The Public Works Dept. has determined that this application is incomplete, please provide us with the following information: 1. Are there any existing utility lines that require relocation due to proposed building addition and construction of new patio. 2. Show o the civil site plan how the roof drain down spouts will be connected to the existing perimeter drain that runs around the building and is already connected to the existing storm drainage system. 3. It appears that during previous construction project lighting pole was augured through the state storm drainage system. Since it is a pressure storm drainage system Public Works has observed water coming out from underneath the light. Applicant shall contact Mr. Ted Freemire, Public Works Operations Manager at 206 - 433 -1860 to coordinate and resolve this problem. 4. Proposed development will add 28 more restaurant seats inside the building and 50 on the new patio. Applicant shall submit a traffic study addressing trip generation and distribution analysis for ADT, AM, Noon, and PM peaks using standard generation rates published by the Institute of Transportation Engineers 2015 horizon year shall be used for "build out" development traffic projections. Level -of- Service ( "LOS ") graduations shall be evaluated - see attached traffic concurrency ordinance #1769 and Mitigation Proportional Fair Share Cost. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 • Fax (206) 4313665 - = ,,,..:.-- - ' 5. Please note that plans for commercial development with the City of Tukwila shall be prepared and stamped by a Professional Engineer, licensed y the State of Washington. All plans shall be drawn to scale, maximum plan size shall be 24" x 36". November 23, 1998 City of Tukwila Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, Washington (98188) RE: Permit Application #D98-0354 Azteca Mexican Restaurant 17555 Southcenter Parkway Building Division: • MERRICK LENTZ ARCIjIJECT Dear Sirs: The following information is in response to your letter of October 27-regarding additional information needed to continue the plan review: Public Works: 1. The roof drains from the proposed addition will be connected into the existing perimeter drain that runs around the building and is already connected to the site drainage system.. (Note added to new Sheet A-1.1) 2. The building will not be fire-sprinkled. (see building department note below) 1. The overall floor plan is provided, showing rooms'and areas labeled along with the existing and proposed exits. (New Sheet A-1.1) 2. The occupancy count is provided. (New Sheet A-1,,1) 3. The building is proposed to be separated by a one-hour assembly into two areas, each less than 5000. Separation includes fire-rated drop-down doors with fusable links at the existing openings between the two areas. Separation will extend from the floor (concrete slab) to the bottom of the roof sheathing above. The wall proposed for providing the separation is existing 1800 - 136th Place N.E., Suite 100 Bellevue, Washington 98005 425/747-3177 • FAX 425/747-7149 E-Mail mlarchitect@isomedia.com and will -be reviewed in the field during the construction phase to assure compliance with the one -hour requirement. If you have other comments or questions, - please let me know.. DATE: PROJECT NAME: APPLICATION NO: PLAN REVIEWER: Determination of incomplete application. BUILDING DIVISION REVIEW Oct. 27, 1998 Azteca Mexican Restaurant addition permit application D98 -0354 Ken Nelsen, Plans Examiner (206) 431 - 3670. 1. An overall building floor plan is required. Floor plans must show all rooms labeled for occupancy use and identify the means of egress. The floor plan will be reviewed for the impact to the existing occupancy and exit systems. 2. Regardless of the chair count noted in the fax memo by Mike Bracher of King County Health, an occupancy count per U.B.C. 1003.2.2 should be provided. 3. The existing un- sprinklered occupancy may be an existing non complying use. U.B.C. Section 904.2.3.1 requires unseparated rooms used for the consumption of alcohol in assembly occupancies exceeding 5,000 square feet to be sprinldered. The existing non compliance may not be increased by the addition without addressing the referenced U.B.C. Section 904. No further comments at this time. October 27, 1998 Rick Lentz 1800 - 136th Place NE, Suite 100 Bellevue, WA 98005 Dear Mr. Lentz: SUBJECT: LETTER OF INCOMPLETE APPLICATION Development Permit Application Number D98 -0354 Azteca Mexican Restaurant 17555 Southcenter Py This letter is to inform you that your permit application received at the City of Tukwila Permit Center on October 21, 1998, was determined to be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Building Division: Contact Ken Nelsen, Plans Examiner, at (206)431 -3670 if you have any questions regarding the attached items. Public Works Department: Contact Joanna Spencer, Associate Engineer, at (206)433 -0179 if you have any questions regarding the following items. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation please submit four (4) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3671. Sincerely, renda Holt Permit Technician end File: D98 -0354 C City of Tukwila iLke/— John W. Rants, Mayor Department of Community Development Steve Lancaster, Director 1. Show how roof drains will be tied to the existing storm drainage system. 2. If the building is going to be sprinklered, a double detector check valve assembly will be required. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431.3670 • Fax (206) 4313665 10/21/96 10:03 206 296 4919 OCT -21 -98 WED 10:13 AM EASTT"TE ENVIRON. HEALTH FAX NO. 2 l.. FAX To: Rick Lentz (425) 747 -7149 (fax) From: Mike Bratcher Seattle -King County Health Dept. Plan Reviewer 296 4919 P. 01/01 Re: Azteca Mexican Restaurant (Applies to both the Tukwilla and Federal Way Stores) The enclosure of the patio area to create more indoor seating (a change of 270 to 298 total chairs) will not require our review. These additional chairs will not increase the permit classification, nor will they require any additional restroom fixtures. Please send us a copy of the changes for our files. Thanks Pls .039, RECEIVED CITY OF TUKWILA OCT 2 1 1998 PERMIT CENTER C � Q!flr'd+ Cvorct CON PLAN REVIEW /ROU I G SLIP DEPARTMENTS: B P �n Division , � Fire Pre ntion Public orks ❑ Structural ACTIVITY NUMBER: D98 -0354 PROJECT NAME: AZTECA RESTAURANT DATE: 2 -5 -99 Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # XX Revision # 1 After Permit Is Issued Planning Division Permit Coordinator ■ DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 2 -9 -99 Complete d rf Incomplete ❑ Comments: TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 3 -9 -99 Approved ❑ \PR•ROUTE.DOC 6/98 Not Applicable ❑ REVIEWERS INITIALS: DATE: Approved with Conditions Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: ..... frn,+ C Coerd. Cop (" PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D98 -0354 PROJECT NAME: AZTECA MEXICAN RESTAURANT Response to Incomplete Letter _ x Response to Correction Letter # 1 Revision # After Permit Is Issued Original Plan Submittal DATE: 01 -04 -99 DEPARTMENTS: BuildJng Division Public Works S RW C.. I -1 ‘tz CI I DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Incomplete C Comments: TUES /THURS ROUTING: Fire FTreiention Attz. 2i Structural Please Route n No further Review Required Routed by Staff El (if routed by staff, make copy to master file and enter into Sierra) Planning I - �j Permit Coo DUE DATE: 01 - 05 - 99 Not Applicable REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 02 - 02 - 99 Approved ❑ Approved with Condition Not Approved (attach comments) n REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved C REVIEWERS INITIALS: DATE. \PR•ROUTE.DOC 6/98 Approved with Conditions 0 Not Approved (attach comments) ❑ ACTIVITY NUMBER: D98 -0354 DATE: 11 -23 -98 PROJECT NAME: AZTECA MEXICAN RESTAURANT Original Plan Submittal Response to Correction Letter # XX Response to Incomplete Letter Revision # After. Permit Is Issued DEPARTMENTS: B i ding Divi ion (X. (z-et- lic Works A` �dct 1z DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete ❑ Comments: TUES /THURS ROUTING: Please Route CORRECTION DETERMINATION: \PR•ROUTE.DOC 6/98 alma &»4 eo,ii PLAN REVIEW /ROUTINL Fire kbUC IO-Z' '6j C Structural Incomplete C CPL - Planning goticrVor Divisin Permit Routed by Staff C (if routed by staff, make copy to master file and enter into Sierra) DUE DATE: 12 1 Not Applicable No further Review Required REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 12 - 1 - 98 Approved ❑ Approved with Conditionsn Not Approved (attach comments) i c ❑ C�V r•e.c — Fi c UY iota bd f(2 REVIEWERS INITIALS: DATE: DUE DATE: Approved ❑ Approved with Conditions 0 Not Approved (attach comments) 0 REVIEWERS INITIALS: DATE. C (. eon PLAN R�W /RO T NrI SLIP : TIVITY NUMBER: D98 -0354 ROJECT NAME: AZTECA M EXICAN `RESTAURA T Original Plan. Submittal Response to..Correction Letter.# DATE . 10 -21 -98 Re to Incomplete, Letter: Revision #; After PermitIs Issued DEPARTMENTS: uilding Division P blic orks y �S t i i)Q& Ib z Complete Comments: DETERMINATION OF COMPLETENESS: (Tues, Thurs) Fire Prev ention (0-2-g1Y tructural kl� Incomplete fr TUES /THURS ROUTING: Please Route a Routed by Staff (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved a Approved with Conditions CORRECTION DETERMINATION: V'R•ROUTE.DOC G/90 REVIEWERS INITIALS: Approved Approved with Conditions a Plartining Division Permit Coordinator DUE DATE: 10 - 22 - 98 Not Applicable LI fiaharkinA kg r io4 /o - Z7 - 1 P Ji No further Review Required a DATE: DUE DATE: 11 -19 -98 Not Approved (attach comments) a DATE: DUE DATE: Not Approved (attach comments) a REVIEWERS INITIALS: DATE: Revision, . • No. Date Received Staff Initials Date Issued Staff Initials I 1 2,-5 -Jq I Or3 Q35-1q Summary of Revision: Summary of Revision: lfl ;nor -- „Structural d dz2J I r6061't • 20.3 e errd - t?) G . Received By: (261A4 C ne / r M Revision No. Date Received Staff Initials Date Issued Staff Initials I Summary of Revision: Summary of Revision: Summary of Revision: Received By: Received By: Revision No. Date Received Staff Initials Date Issued Staff Initials I I I I Summary of Revision: Summary of Revision: Received By: Revision No. Date Received Staff Initials Date Issued Staff Initials I I 1 Summary of Revision: Summary of Revision: Received By: Revision No. Date Received Staff Initials Date Issued Staff Initials I 1 Summary of Revision: Received By: PROJECT NAME: O. ►'1 a.UrZZJ7 f" PER NO:. c8 -U35 Site Address: M1& S I� Pa.rkwa Origl ...4 Issue Date: �J REVISION LOG (please print) (please print) (please print) (please print) (please print i1 REVISION SUBMITTAL DATE: 2, 4 % 9 PLAN CHECK/PERMIT NUMBER: / 5 '5;1 PROJECT NAME: Ar �' �rL;‘9, > PROJECT ADDRESS: , CONTACT PERSON: ,C �C2 �' f7 REVISION SUMMARY: !t)e 2 g cris --- 5 SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: Bldg. •z/V CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 CITY USE ONLY Planning: Fire. PHONE: 4 ?S 7 74t 7, 3/ 7 7 A �• ? too Public Works 3/19/96 02/04/99' 11:14 CMA RESTAURANT SUPPLY * 2064313665 To City of Tukwila Fax 9: 431.3665 Mu Ray Cuieur - Building Inspector Franc Rick Lentz Daft February 4, 1999 loe Aztec, Southcenter - Framing Inspection Pap= 4 including cover sheet Rick Lentz MERRICK LENTZ AR "' p9S Please don't hesitate to call if you have any questions or comments. 1800 • l36' Place N.1", Suite 100 Rallovue, Washington 98005 425,747.3177 FAX 425.747.7149 E Mall miarch ®lsom ia,cam Dear Ray, The contractor called us yesterday and Informed us that a portion of the new parapet and mansard was not built according to the plans, We performed a site observation this morning and confirmed that a portion of the construction is not according to the plans. However the as -built condition appears to be a satisfactory alternative. The construction method performed is adequate to provide equivalent performance. At the contractor's request we have produced an alternate detail showing the revised construction and have enclosed the detail. In addition, we've enclosed structural calculations showing the adequacy of the installed 4X10 DF 01 header. FAXt ran Sm ittal N0 :2132' 701 REVISION Na s-o�f- 0244/99 11:14 CMA RESTAURANT SUPPLY 9 2064313665 MERRICK LENTZ ARC ITECT WOO - 196th Place N.B„ Suite 100 Bellevue, Washington 98006' ' 1906) 747 -3177 FAX (306) 747 -7149 NO.282 D02 JOB NAME AVTIOdk �.OI�T'�ICF•f.? . WfNDotN fro+ • • ( • ► ► �,� ,_.-__. f • , ... u.i 5'* 60 . 1457 / Z . 2 i • • .; 141. * -I- ■. s - .1 .2q • S'!' /ft- c . , t.P' E :DATE' SHEET j OF 1 ( 4 t q -- J ,1- .' Rte g6dDD 0() - TlW(v 4x10 D: t }-0NoV& t tsizo. 3g, , OK-1 r . 6)41TIW.0 4g-10 'bP 1 146Peet 15 O1 E t • 02/04/99 11:14 CMA RESTAURANT SUPPLY 4 2064313665 C ' BLOCKING HEADER CITY tig RgXIS71O FOUNDATION FEB U 9 1999 NO 1 'ED L UILUNG oIV? oN • 1131135MENIL ll• II 7 rjr p.� fl 4 r ' " 7X BRAIN STEL PLATES • CUCTIO -PLY ROOING, ▪ UILDING PAP °_R 1/2' CDX PLYWD, SHEATHNG, 7X17 JOISTa Ib" O.G. -30 BATT INSUL, (FACED STALIOR FACD BATTS), PLYW, SHETHIG. vAPR RETAER, STUCCO OYE MTAL LATU (FINIH TO MATH EXISTIN NEW CERAMIC TILE FLOORING PARAET CA (MATCH EXISTING - NEON TUE A) Ibd NAIL 2X17 LEDGER W/ I/7' DIA LAG BOLTS o 32" DC. TILE OER 1) 4 SAC - 6 cEILI - 0 • SI I mmum ^ NEW CONTE WALK ANCHOR 1501-TS • 60` OrC. R.10 RIGID INSULATION WALL SeGTION SCALE, 1/2" • 1'.0" ' IT •0• TOP OF CUM ED PARAPET 13'•6" TGP CV LOW PARAPET NO.282 D03 MONO T13JS9 • 24'O,C, 7X FASCIA g' -o HEADER 5/13" GLUE, SOFFIT 1X4 TRIM (ARO1JND WINDOW • SEE ELEvS) INSUL. GLAZIIt r W 1/7• AIR SPACE EXTERIOR WALLS STUCCO (FINISH TO MATCH EXISTING) , OYER METAL LATH. Ii• WILDING PAPER PLYWD. SHEATHING, 2X2( STUDS • IV O.C. R -19 BATT INSULlPACED STAPLING OF PAGED BATTS). S/6' *WA,. vAPOJ! TO MATTCH RETARDER. L sINTERIOR FINISH) 0' -0" FINISH FLOOR • 02/04/99' 11:02 CMA RESTAURANT SUPPLY 4 2064313665 Tae City of Tukwila Fax* 431.3665 Albs Ray Culler - Building Inspector Irons Rick Lentz Data February 4, 1999 Rat Azteca, Southoenter - Framing Inspection nig= /; induding cover sheet Rick Lentz MERRICK LENTZ ARCHITECT FAXtransmitta.I Please don't hesitate to call If you have any questions or comments. 1800.136Th Place N.E., Suito 100 Bellevue, Wwrhintgon 98005 425.747.3177 FAX 425.747,7149 E•Mail: mlorchisomediacom Dear Ray. The oontracta called us yesterday and informed us that a portion d the new parapet and mansard was not built according to the plans. We performed a site observation this morning and confirmed that a portion of the construction is not according to the plans. However the as -built condition appears to be a satisfactory alternative. The construction method performed is adequate to provide equivalent performance. At the contractors request we have produced an alternate detail sheering the revised construction and have enclosed the detail. In addition, we've enclosed structural calculations showing the adequacy of the installed 4X10 DF *1 header. NO.280 D01 • 02/04/99 • 11:02 CIA RESTPURANT SLPPLY 9 2064313665 MERRICK LENTZ ARC ITECT JOB NAME r -7044 -' c-J01j1 40.KYCV. W1t &1J {4 10 ,Ifectwic4. CgIkl'S /A *'40.0 1X1.7 , ) OieK tfc2:...... . j' ... J Q r`l, 5# 60. 3,:) : 1457 2 . �'.., 1Gzs��15-:'— 14s? • I , * . (. q7) 14. o iuy rReA RJD C11 C- . (IyT)N& 1 4-X . 10 V., 1 IDe Plfrotir c*. 3z.vb Z o. OK-AM DATE._ : SHEET OF • �� 52Q� Sri t C1 Nlo 4 %d o ...17,P 4 ( H6Pd R i 5 Dgfrti v 1800 - 186th Place I1.E., Snits. 100 Bellevue, Washington 98006 1806) 7474177 FAX 1906) 747-7149 NO. 280 CO2 • 02/04/99 11:02 CMA RESTAURANT SUPPLY 4 2064313665 1 2X GRACING STEEL PLATES BLOCKING BLOCKING WEAR =R linfinfriEffr ROOF CONSTRUCTION: SINGLE -PLY ROOFING, BUILDING PAPER 1/2" COX PLTWD. SWEATWING, 1X12 JOISTS • IS" O.C. R -30 BATT INSUL. (FACED STAPLING OP PACED HAM). PL•WD. SHEATWING, VAPOR RETARZER 6TUGCO OYER METAL LATH (PINISH TO MATCH EXISTING) NEW CERAMIC TILE FLOORING EXI5TRJG CONC, FLOOR SLAP CImIINCT lllilh'iLA Artiliwto E" E E3 0 9 1999 Ati NOM) P3i.11i_.l)rN(•A DR? OPd tb): r \/ NEW CONCRETE WALK ANCHOR BOLTS • AB' O. R•10 RIGID INSULATION WALL SECTION SCALE. 1n" • r -m" n'-e TOP OP CURVED PARAPET PARAPET CAP (MATCH EXISTING - TTP) NEON TUBE (4) I60 NAILS 2X12 LEDGER I11) 1!2' DIA LAG BOLTS • 32" O.C. TILE OVER Dfm SPACERS s a'- A•CEILM NO.280 D03 MONO TI2155 • 24•0C. 2X FASCIA 4 -0" WEADER Sig" auto. SOFFIT 1x4 TRIM /AROUND WINDOW - 58E nLEVS) INBUL. GLAZING tJ I/1" AIR SPACE 3' - O' SILL EXTERfOR WALL. STUCCO (FINIS) TO MATCW EXISTING) OVER METAL LAtW, 15• BUILDING PAPER. PLTIUD. SHEATHING, 2X• STUDS • K` O.C. R•19 BATT INSULJFAC`O STAPLING OF PACED BATTS), 5(b' (11118, v4POR TO MATTCIEX 5 P( INTE FINISI4) m'•O" FINISH FLOOR 02/04/99 ' 11:02 CM A RESTAURANT SUPPLY 4 2064313665 coy. 52.9Ti I,LU CONT. CONCRETE FOUNDATION WALL — errat). =.4FIRF1 — EXISTING CITY OF TUKWItil APPROVED FEB 0 9 1999 NOILIJ t31.11LOING oFt1170f4 SEE FLOOR PLAN FOR DOOR AND WINDOW INFORMATION ROOM Argl40441 ifeilAN SOALEt s NO.280 D04 02/,O4/99 11:14 CMA RESTAURANT SUPPLY 4 2064313665 C N CITY OF TLJKWILA APPROVED FEB 0 9 1999 WILL L.C., CiV -X1611NerCONCREIV — GLAD ON cliRAVE -- tCONPIRrfeXI6TINO7 sE LoOR PLAN FOR 000* AND WINDOW INSOlirtATION SCALE' I/4 • 1 TExi5TING NEW aXIN coNT. FOOT WI 6" CONT. CONCRETE FOUNDATION WALL rTY'req. coNrifer1 CX16TINCS — 242 J016T6 • 16" OW II" ROIVID NE WON I tfith RN. A NI NO.282 DO4 CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: JAM . � t 1411 PLAN CHECK/PERMIT NUMBER: • PROJECT NAME: PROJECT ADDRESS: 11351 10(1414 ry CONTACT PERSON: Witt PHONE: REVISION SUMMARY: ft5 folJCE GET-lee. To Po iSt lC, w ()US FwS 1W W. ANA;u &t'S PcS wet5zro ,CNo DOsoOLY 0011s lo/i S LJ I✓ RECEIVED CITY OP TUKWILA JAN 0 'I 1998 PERMIT CENTER SUBMITTED TO: SHEET NUMBER(S) INt/k "Cloud" or highlight all areas of revisions and date revisions. CITY USE ONLY 3/19/96 CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard,. Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL PLAN CHECK/PERMIT NUMBER: pia_ 0 DATE: Nov �� rile PROJECT NAME: f PROJECT ADDRESS: (•16 5041 py CONTACT PERSON: Ri (ii4t PHONE: ( 7 - 7 - 3977 • REVISION SUMMARY: NOM A990 04 I a7F L f r' (tiJAiCGTaJ• I30/u7n J4 w l U. ohs( l& noe sPpinl t✓I-60 - o1JE kkvk 5E49,4-pl. WA-LC,, tin Lou. -powr\J Agra Un11 Pi R' PooRS AWE ' Ato.4 wvr/- NEkl � (I DIN IN 6 KooNl . D(GVPAr1 o ( 1SBD7 imi sEPIT Cou&T( )t) D /N�NZj '1 (12 e ANA aq tiA-P2 frvrica, VA wA - notJ i 1 Look4r. DM A4) . Fwae, 7(/Igf\) 1 11v - tui pi1J4 t Is rpothseio ? T 0 4 0 0 y9 a FpMt � cF 98 SHEET NUMBER(S) IS A NN' S ETT 1N ITS 6N1'l '1 "Cloud" or highlight all areas of revisions and date revisions. Bldg. Planning Flre; SUBMITTED TO: CITY USE ONLY Public. Works 3/19/96 cf Dear Sir: c City of Tukwila Fire Department Fire Department Review Control #D98 -0354 (511) October 29, 1998 Thomas P. Keefe, Fire Chief Re: Azteca Mexican Restaurant - 17555 Southcenter Parkway The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57.5-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1003.3.1.5) Exit doors from a group A, E or I occupancy having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. (UBC 1007.2.5, 1007 -3.10, 1007.5.8) 3. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) When two or more exits from a story are required and when two or more exits froma room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57$.4404 • Fax (206) 57$.4439 C City of Tukwila Fire Department Page number 3 All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) 4. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.4.2) 5. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 6. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 7. When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of Uniform Building Code 803. The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax: (206) 5754439 Page number City of Tukwila Fire Department Ordinance #1742) Any overlooked hazardous condition and /or violation of adopted Fire or Building Codes does not imply approval such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station; 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 01/17/1995 04:58 360652805 F623-052.000 (8/97) DEPARTMENT OF LA8012 AND INDUSTRIES • REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL • to • DYNATECH DYNA "TECH CONSTRUCTICORD • 1829 188TH N E ARLINGTON WA 98223.'; PAGE 01 �1s / I / NO REVISION TO EXISTING PARKING CR006 ACCESS / RECIPROCAL PARKING AGREEMENT WITH ADJACENT PARK PLACE SHOPPING CENTER PROJECT NOTES: PROJECT TENANT: PROJECT ADDRESS: GOVERNG CODE: ENERGY CODE: AZTECA MEXICAN RESTAURANT 11555 SOUTHCENTER PINEY. TUKWILA, WA 58185 1991 158051 BUILDING CODE 1995 WASHINGTON STATE ENERGY CODE OCCUPANCY A -3 CONSTIHICTICN TYPE: V -N (505-40155550) TAX ACCOUNT N8EER 4200-316341-40 SCOPE OF WORK: 800 ea T. ADDITION TO AN EXISTING 1.450 SG FT. 55814URA4T LEGAL 17ESCRIPTION: THAT PORTION OF TIE SOUTHEAST I/4 OT THE 40TTFWEST 1/4 OF SECTION 26, 10161514140 23 NORTH, RANGE 4 EAST, WM. AND THE NORTHEAST 34 OF THE NORTHWEST I/4 CF SECTION 38, TAM/SHIP 13 NORTH, RAGE 4 EAST, WM. M KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS, DE INNING AT THE NORTHEAST CORNER OF SAID NORTHEAST V4 CF THE NORTHWEST V4, THENCE NORTH 81 45' 51" 4.E51 ALONG 114E NORTH LINE OF SAID NORTHEAST 1/4 CF THE 504014 4541 1/4, A DISTANCE OF 481335 PEET TO THE ILEST MARGIN CF 60UTHCENTER PARKUJAY AND 114E POINT CF BEG5ING: THENCE SMITH II 59' 33" EAST 10NG SAID WEST MARGIN A DISTANCE OF 2421 FAT, THENCE NORTH 61 49' 51° WEST A DISTANCE OF 21000 FEET, THENCE NORTH II 59' 33° I453T A DISTANCE OF 24945 FEET. MENDE 6015TH 81 45' 51° EAST A 0181410E OF 21000 FEET TO SAID 4.891 MARGIN OP SOUTIICENTER PARKWAY, TL4e4CE SOUTH II 65' 33" EAST ALONG SAID 4887 MARGIN A DISTANCE OF 21.321 FEET TO THE TRJE POINT OF BOWMEN5, ENERGY NOTES: ELECTRIC RESISTANCE 14EA1 IS NOT ALLOWED. ALL EXTERIOR DOORS TO BE IL8ATHER5TRIPPED. ALL SEAMS AND JOINTS TO 85 SEALED, CAULKED OR G4&CETED. OWNER: TENANT: TRA'R'ELL 040010 COMPANY 11900 5OU13=41819.0 AY, 811178 215 1IYtl19LA, 15.4.90100 AZTECS 8591AU4ANT ENTERPRISES, INC. 133 NIA 14614 875557 SEATTI.8, W4 55166 ARCH I T EC 4'.585090 LEMZ 45544,19417 ° 1500 - 134TH 40L 4>C8 NE, 8887E 100 BELLEWE, 154 98@03 I understand that the Plan Check approvals are subject to errors and omissions and approval of tans does not authorize the violation of any dopted code or ordinance. Receipt of con - 410104'0 copy of approved plans acknowledged. By Date /` � -` � Permit No SEPARATE PERMIT RE IRED FOR: MECHANICAL ELECTRICAL PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION cl CY OF TUKWILA APPROVED AN i Y 0999 8 7 1LDING DIVISION UNPUBLISHED. WORK 01998 IERRiiCCK LENTZ A4014IT£CT MERRICK Lenz ARC : C' 1800 - 138th Place N.B.. Suite 100 Bellevue, Washis(ton 98005 425/747 -9177 808 425/747 -7149 B -mail: miarchOlsomedla.com PROJECT NAME AZTEC A MEXICAN RESTAURANT 41555 $$UT+ LA c1NY TER Pi FILE _ CONY -. TUKWILA, A4 4 alEiI & D4* OCT 6411N RECEIVED .CITY OF TUKWILA 0 C 2 1 1998 PERMIT CENTEIT UJINDOUJ SCHEDULE LE'I1ERW 510E (W AWN / TYPE MATERIAL GLAZING U- VALUE SHGC REMARKS O e' -0° x 5' -0" / ARCED VINYL DOUBLE 40 10 HEAD • e' -0° O K -4" x 9' -0" / ARCHED AMYL DOUBLE 50 10 HEAD • S' -0• O 6'- V x K -0" / ARCHED VINYL DOUBLE •0 10 HEAD • e' -0" pO e' -0" G 9' -0" / ARCED VINYL DOUBLE 50 It 1 • 8' -0° O 4'-0 . x 5' -0" / NEC T. VINYL DOUBLE 60 NA LEAD • 8' -0" U RELOCATED - USE EXISTENT ENTRY WINDOW 4,101 EAST WALL (El EXISTING, TO REMAIN LIGI -STING SCHEDULE STNBOL TYPE T WATTAGE 0 RECESSED CAN • 13 9 ITT TOTAL • 190 SF WALL- MQI1IED DECORATING LIGHT A 60 WATTS 2 420 BH CHANDELIER • 320 WATTS I 320 TOTAL • 551 GLAZING AREA CALC. WINDOW AREA WALL AREA , O B • 31A SF IEIGAT • 10' - 6" OC • 31.4 EF LENGTH • 28' - 3° • 2I' - I" DO • 44A SF . 49'•4' TOTAL • 190 SF • RS SF GLAZING • 192 /515 3 100 • 235. DOOR DOOR FRAM CRIER W SIZE T xLItt MAIL. FE) TYPE NATL. WIDTH THR CLOSER R B REMARKS O 3' -0" x 0-0,1 3/0 SC WOOD STAIN A HP1 2° YES YES A O 3' -0 x S' -0" x 1 3/4" SC WOOD STAIN A HM 2° YES YES A O RELOCATED - USE EXISTING ENTRY DOOR (REFER TO ELEVATION CHANDELIER ADOVE DINING (FLOORING - TILE) (CEILING - GW®) D MOUNTED DECORATIVE GHT (rr P L ) LIGHT (N) RECESSED CAN (MEP) VESTIBULE a TILE ROOF ABOVE NEW CONCRETE WALK 40' HIGH FURRED COLUMN 35" HIGH RAILING AROUND NEW PATIO (SEE SWEET A -2) EXISTING CONCRETE WALK (TYPE TILE ROOF ABOVE P1S -03 EMERGENCY EXIT NO LOCKING MECHANISM (SPRING HINGES) EXISTING LOUNGE REPLACE WINDOW WITH WALL .36" LEGEND EIOSTK3 TO RB•AN REIGNS EERIE WALL NEE WALL DOOR H ERASE SE DOOR POQILE FOR IFORHATICE. ENDOW STI"BOL SEE SCHEDULE FOR BEORWTEN HOSTESS E- (RELOCATE TO E RDOL FO REFER TO EC4'EDILE) (RELOCATED REFER TO SCHEDULE) NIGHT LOSIT WAITINS (RELOCATED REFER NEW CONCRETE WALK NOTES I. ALL EXTERIOR WALLS ARE 5 V2° STUDS 020 2. ALL NTERIOR BALLS ARE 3 1/2 STUDS Uri0 3. PROVIDE THREE SILENCERS PER DOOR 4. PRONDE WALL WIPERS OR 0.3OR manna, DOOR STOPS FOR EACH DOOR AS REal1RI. 5. ELECTRIC RESISTANCE NEAT IS NOT ALLOWED. 6. PR VIDE VAPOR RETARDERS ON WW1 SIDE GERE APPLCAaLE hLOOR/REFLEGTW GE I L I NO FLAN I/4 ".I -0 DOOR SCHEDULE LIGHTING CONTROLS SCHEDULE: SR®0L 9 TYPE SWITCH SWITCH SWITCH SWITCH SWITCH TT'IE CLOCK FIXTURE(5) CONTROLLED (NUMBER CF LIGHTS) RECESSED CANS (S AT TABLES - MGR TO KAKI RECESSED CANS AT SOUTH END CF ADDITION (3 LIGHTS - REFER TO PLAN) INTERIOR MALL- MOUNTED DECOR LIGHTS (2) CHANDELIER II EXTERIOR WALL- MONTED DECOR LIGHTS IS) NEON SAND AROUND BUILDING LOCATION HOSTESS HOSTESS HOSTESS HOSTESS HOSTESS HOSTESS HARDWARE SETS A CYLINDER LOCK PANIC DEVICE, THRESHOLD, CLOSER WFATHEER- STRPPMG,I IC PAIR BUTT HINGES. DOOR TYPES ENE ENE ENE ••• . A . �'. �Y IJI IIII���I�F APPROVE JAN I tD99 d 0∎NG DArtsloN UNPUBLISHED WORK 01998 MERRICK LENTZ ARCHITECT MERRICK LENTZ ARC ITECT 1800 - 130th Place N.B.. Suite 100 Bellevue, Washington 98005 425/747 -3177 FAX 425/747 -7149 B -mall: mlercho/somedla.00m SERRICK D. STATE GE WABIOGTON PROJECT NAME DRAWING TITLE AZTEGJA MEXICAN RESTAURANT I'1555 SOUTHGENTER PKWY TUKWILA, WA 4 18188 FLOOR PLAN 4 SCHEDULES DATE OCTOBER IS, 1995 DRAWN BY NG CHECKED BY " REVISIONS OFT CITY OF TU KWIIA OCT 2 1 1998 YEAST CENTER ,� Aa- LOUNGE (1245 8F) (000 a LAS •83) DINING (550 SF) (FIXED SEATS .22) WAITING MIS SF) (OCC. • Ins •35) PORTION ION 8 - 4660 e DROP DOW 11A2 FIRE ve. M STEEL FRAME (FIXED SEATS .501 DROP DOA DINING B I HR FIRE DR. (508 SF) (FIXED SEATS .44) STOR. (T6 SF) DINING C (130 SF) (FIXED SEATS .82) NEW 3'- 0"xT -0• EXIT DO RIW PANIC Wale E REMOVE LANDBCAPNG TO ACCOMODATE NEW 5' -0' WIDE CONC. WALK - REMOVE QJE --) BOOTH TO ACCOMODATE NEW Exit EXISTING PATIO SgGOND FLOOR (SIX SF) )OCC. • I/700 .4) NEW CONC WALK LEGEND 4 NOTE acmcaramcm -FIGUR FIRE WALL CONNECT DCUNSPOUT$ TO EXISTING 8701 DRAINAGE SYSTEM. 1$ —x354 KITCHEN STOR. DROP DOM STORAGE I HR FIRE DR (333 85- FOR 2 STORAGE SPACES N STA880AY) NEW 00140. WALK FLOOR D I AGRAM SCALE: I/8" • I' -0" FIRE DOOR DETA SCALE: 1" • 1.-0" FASCIA LINE ABOVE FASCIA M0VI4TNG °HAN EL AEKXVE TRASH ENCLOSURE SCALE 1" • I' -0• EXIT DOOR IIV PANIC HOUR REMOVE LANDSCAPMG TO ACCOMODATE NEW 5' -0" WIDE COLIC. WALK 54 PHILLIPS PAN 14EA0 TAPPING SCREWS 3" L01K W STEEL 4 FIBER WASHERS, IS" 00 MAX FIRE DOOR PETAL PLAN OCCUPANCY pownct4 I A I WAITING • 35 NEW DINING • 22 LOUNGE • 53 5ECCND PLR = 4 TOTAL • 144 IreT9rlaN • 50 DINING A DINING 15 DINING C = 52 KITCHEN • 9 TOTAL • 185 These Plans have been revise-ter by the Public Works I - gent for cc- , a 12)1)1 C'p F. _ rors ads ccrcc e t 'Cly the the, _ c ' fte ecceptcnee and 4. I . . tal of realsed Cr... n - I r cuL,�_;_ . he /royal Flnr' 't ocl to' - 'd inspection by ih� ! 1.:,. :. ins , i qq 'yy cos i W 5D U I'#}S- but ILE Mau IMP SilOI.J' MN 96 GA HOW J)OIANSPOUTS ARe STEEL "'De. CONNECTEC) "f17 c.xlsTla4 4 1 I BILL AT JAM STofR-1'l tk P IPA6e SYSTEM. STEEL ET PLATS ABOVE ppp0000 308 2 •L ,9 atdC DIVISION AECEIVED CITVOFNKWI NOV PERMIT CENTER P1& -0354 UNPUBLISHED WORK 01998 MERRICK LENTZ ARCHITECT MERRICK LENTZ ARC ITECT 1800 - 13858. Mee N-H-, Suite 100 Revue. VFeebin/Wn 88000 425 PAX 488/747 -7168 na111 mierohOlaomedia.eem PROJECT NAME AZTEGA MEXICAN RESTAU1RAWT IT555 SOUTHGENTCR 1mK8MY TUKNIILA, INA 98188 DRAWING TITLE FLOOR DIASR/ M 4 DETAILS DATE NOvEMESE R 23,.198E6 DRAWN BY NG CHECKED BY RE ISIONS A-1a m SSIGNASE BY OTHERS BUILDING BEYOND BRICK (TIP) CERAMIC TILE (TIP) NEW WINDOW (TIP, UNA) (REFER TO SCHEDULE- TYP) NORTH ELEVATION REMOVED SECOND FLOOR WINDOW BUILDING BEY01D— EXISTING WINDOW RAILING AROUND NEIN PATIO (BLOCKED OUT FOR CLARITY) C in EAST ELEVATION I/4•.I' -0" NEW ADDITION EX151198 RELOCATED WINDOW I AILING 1Eatyg_ c 1 NEW DOOR (REFER TO SCHEDULE - TYP) EXISTING NEW ADDITION NEW POOR' NEW WINDOW (TIP, U.ND) 4' O -o MEM ._ ..o HEW FURRED COLUMN (TIP) STUCCO (TYP) TILE ROOF (TIP) STUCCO (TIP) REVEALS (TIP) iV Or Ilil(I I A APPROVED JAN 1 2 1999 RDING DIVISION UNPUBLISHED WORK 01998 MERRICK LENTS ARCHITECT MERRICK LENTZ ARCHITECT 1800 - 136th Place N.E.. Butte 100 Bellevue, Wealaluston 96005 206/747 -9177 Y42 206/747 -7149 PROJECT NAME 1 /S' REGISTERED I ORGITECT MERRICK D. LBlT? STATE a WASI/IGROI AZTECA MEXICAN CAN RESTAURANT 11666 SOUTNCIENTER PION TUKWILA, WA 98188 DRAWING TITLE ExTsitioNt 4 IE�4Il.INGr M VATION DATE OCTODER IS, 19QB DRAWN BY ML CHEC BY REVISIONS CITY OF TUKWILA ULI C 11190 fun DOOR SEE E UFOR ATI ON 2E12 JOISTS • IS" O.C. FLOOR PLAN FOR \4 POUMPATION PLAN SCALE 1/4" , 1' -0" EXISTING CONCRETE SLAB ON GRADE (CUBISM EXISTING) 2X BRACING STEEL PLATES BLOCKING ROOF CONSTRUCTION. SINGLE -PLY ROOFING, BUILD NG PAPER DE' COX PLYUO. SHEATHING, 2XI2 JOISTS II•N �IR .0 IR 0 � ,q . ,�� pp ,,�qpLL V BATT8 APOR RETARDER, VAPOR TUCCO OVER METAL LATH (FINISH TO MATCH EXISTING) BLOCKING HEADER NEW CERAMIC TILE FLOORING— EXISTING CONC. FLOOR SLAB EXISTING POA4DATION TOP OP PARAPET SCALE- 1 -1/2" *11 TOP Of CtW VED PARAPET PARAPET CAP (MATCH EXISTNG - TYP) NEON THE 'AXIS) LEDGER W/ 52" DA LAG BOLTS • 32" DC. TILE OVER DC4 SPACERS A IO'- b "OEILIF* MONO TRIES • 24 "OC. 2X FASCIA 2 HEADER 5/8" GLUE. SOFFIT 5)4 TRRM (AROUND WRDCW - SEE ELEVSJ MSUL. GLAZING W I/U" AIR SPACE 3'-0" SILL EXTERIOR WALL: ST' (F E i TO MATCH EXISTING) OVER PETAL LATH, FJ BUIIL� DING PAPER, R PLYUL -IS SA *IUFACED STAPLING O" .C. PAC AB BATTS), S/S" G. VAPOR RETRDER, METAL LA_,_114 STUCCO (FINISH TO MATCH EXISTING NTEMOR FINISH) 0 FROSN FLOOR NEW CONCRETE WALK ANCHOR BOLTS • 40 R -10 RIGID INSULATION !, k%4 1 SECTION Q PU RREi7 COLUMN PLAN A-3 SCALE- 1 -1,2" , 1' -0" EXISTING WALL PURRED COLUMN nAN SCALE: 1 -1/2" • P -0" PARAPET SEE N CAP ABOVE SEE UN%1BUSKED' WORK 01998 MEERICI( LENTZ AP HITECT MERRICK ''N ARC • ECT 1800 - 138th Pleas P3. BuR4 100 aitifseet 429 0 -3177 -8177 P /'P0 - 11-91811: adatehOteenx4418.oesn PROJECT NAME AZTECA MEXICAN RESTAURANT rt555 WU »1Gt$N' t MAW TL*'4 -/A, WPt 40106 DRAWING ? LE out