Loading...
HomeMy WebLinkAboutPermit D98-0420 - NORTH VALLEY BUSINESS PARK - WALLD98 -0420 17680 West Valley Hwy. North Valley Business Park City of Tukwila c Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 252304 -9017 Address: 17680 WEST VALLEY HY Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: Permit Center Authorized Signature:_ Signature: DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. AWSE DEVPERM 001 North: .0 South: TUKWILA Sewer: W Slopes: .0. TUKWILA Y Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: East: .0 West: Streams: End Time: Public: (206) 431 -3670 098 -0420 ISSUED 01/06/1999 07/05/1999 WAREHOUSE 1997 SPRINKLERS .0 Contractor License No: DDMORCCO55JD OCCUPANT NORTH. VALLEY BUSINESS PARK 17680 WEST VALLEY HY, TUKWILA WA 98188 OWNER NORTH VALLEY PARTNERSHIP • C/O REIS GROUP, 13221 SE 26. ST #M, BELLEVUE WA CONTACT TORVAN RONHOVDE Phone: 425- 656 -0500 6625 S 190 ST, #B -107, KENT WA 98032 CONTRACTOR D D MORRISON CONST CO INC Phone: 4257271 -9551 PO BOX 2110, RENTON WA 98056 * * *** is ***** **.************ *** e ** ****** ** * ** * * * * *** * ** ***** * ** lr* : kit *•k**: *fit ****** *•k * ** lt** Permit Description: CONSTRUCT DEMISING WALL - EXISTING TENANT EXPANDING INTO ADJACENT SPACE. ******************• k************* . ***.******************* * * * * *•k * * * * * *** *** ** * * * * * * * * * ** Construction Valuation: $ 15,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Sepa Eng:. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: 'Size(in): .00 flood Control Zone: N Hauling: N Start Time: End lime: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving'Oversized Load: N Start Time:. Sanitary Side Sewer: N No: Sewer Main Extension: Al Private: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: *******************• k• k*******************************• k * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 419.06 ***************************************** *********** * * * ** * * * * * * * * * ** * * * * * * * * * * * * ** Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development ermit. P t Date: 1 -&-97 Print Name :PU6 Ia.S �/ ofeiSci This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 17680 WEST VALLEY HY Suite: Tenant: Type: DEWERM Parcel #: 252304-9017 CITY OF TUKWILA Permit No4s1J)98-0420 (tatus:-ISSUED Applied: 12/09/:1998 Issued: 01/06/1999 *lek'k*********A*** Permit Condition: 1 - . No chances w i l l be made to the plans unless approved by the '.:Archi tett or Enaineer and the Bu l id ina Division. 2. A 1 1 permits inspect i on plans shat be . a v a i l a b l e at the job site %.-prior to the s tat1 any con- truction. Thes644OcUMents are to. be ma intatne'd.„and avail- able until tinal lripect1on approval L gv.nted . Al 1 construction to be done I 14, approved • p 1 an and .JT;e:qUi re,Ments„ Of the Ur f or 6 8ui 1 d iro Code , (a;:,97 •Ed i t ion) men d$d Uniform Mecha fc.al,,: Co Ed it fon),. • and Washing State Energy 'patie (1997 EN; - • 4 1.. Val id i,t4:/of Prm t The I sS.Uance,:of a permit or p l a n s ar spec ifi cat tons ar0/i'omputat,ions shall not be con S tr. lied to be a ,p,e'tin)i tf‘OK,' - Of an ap'prova 1 of , any violation 'of nv of the prOv'isiOns of the building .code or of any o ther ordinaice the ju isdict Ion. No. permit pre s UM'1a to o ye author 1 ty:' to v iolte or cr,ce1 the prov 1 3 IOfl of th is sha 11 . b a 1 • • •'••••,:` • • • ,! • • '•••''' .. r.' •i:r.-./.. ''•,•'•' '',....: ..' ' I ; .., • t.1 • • •'• - ••••••• 77'•:Ak, Project N e , : ll / enant qr a s , re z } emdi�l Gera, /!/ Value of C strut ion: /, Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ School /College /University ❑ Other Site Address.: ' // ,G y City State /Zip: /7 2 lam' 0 G r el 6 /� I Tax Parcel flu / 2c Jm�1 �0/ "t�?r Property Q -m G eos v a e Phone: Existing fire protection features: ,sprinklers ❑ automatic fire alarm El none El other (specify) S r t ess: r- y t to /Zi Sir1— 2 2� s T #07 ,,e7 /PGA ' Cit y Fax #: Will there be storage of flammable /combustible hazardous material in the building? ❑ yes )■'t no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Contractor: i Phone: Street Address: City State /Zip: Fax #: Architect: e /� OAL ,�^ Z4 J , d i v10C� Pho s- —OS 7 Z ,1 `LSD � C it State /Zip: v 0 -7 ,„ 8/ yam Art Addre : /c � D� Fax # .s 6 -0 / Engineer: / Phone: Street Address: City State /Zip: Fax #: Can;aet rs RoAwo e Phone: Street Address: City State /Zip: Fax #: Description of work to be done: //07Z) ,47)&.I7 -- Co0s 72(,Cr x/51/k) 6 4t'46C -- ,g ls; 1 7 -6 -- Existing use: ❑ Retail CI Restaurant ❑ Multi- family Warehouse ❑Hospital CI Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ School /College /University ❑ Other Warehouse ❑ Hospital ❑ Office Will there be a change of use? ❑ yes no no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes ano Existing fire protection features: ,sprinklers ❑ automatic fire alarm El none El other (specify) Building Square Feet: NO, existing i Area of Construction: (sq. ft.) A /A- Will there be storage of flammable /combustible hazardous material in the building? ❑ yes )■'t no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKP a ILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW.OF THE.FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ ❑ Fire Loop /Hydrant (main to vault) #: ❑ Land Altering 0 Cut El Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Curb cut/Access /Sidewalk ❑ Flood Control Zone Size(s): :ubic yds. 0 Fill cubic yds. ❑ Sewer Main Extension ❑ Water Main Extension 0 Deduct OR STAFF USE ONLY Project Number : Permit Number: -c4zo ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 1Z —q -1q Date application expires: Appl Jlon taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERM)T.DOC 1 /29/97 BU/LDIILam" , WN R UTHORIZ AGENT: Signs .f : ,� G Date: /2 -.. C 7O Print name: 70Jm.� poisityoVD P2792:3-.....66-6 —00u I Fax - 656-00f Addres 7 1 S /0 it S/ i-8l p'-. City /State /Zip A cam' geo Z ALL COMMERCIAUMULTI-FAMILY TENANT IMPROVEMENT /A R ATION PERMIT APPLICATIONS M BE SUBMITTED WITH THE FOL WING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER D. ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN Y BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Cif Floor plan: show location of tenant space with proposed use of each room labeled ❑ 11 Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ra. Vicinity Map showing location of site r ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ 11� Indicate proposed construction of tenant space or addition and walls being demolished ❑ LX! Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. 7 1 ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). 5 _ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. tf -_ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF jHE.,STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPLI<MIT.DOC 1/29/97 Account Code 000/322.100 000/3.136.904 *•t ******A* *•h*A•k* *h** *h**•A-k ** *Ask **kA *A4.*Ado;A* *** *A•.ck• * *•k•* *A CITY OF TUKWILA,, WA TRANSMII hA k;k:4•h•* ***:k•k*A*A k* *****:k;k:k:t•k* A* ky4•, Al *A4 •.t* *** A :k *** .. TRANSMIT Number: R4300000 Amount: 255.75 01/06/99 1.0 :33 Payment Method: CHLCI: Notation: D 0 34QRRISON CON Init': `RLH .: Permit No: 098 -0420. Type: DEVPERI4 DEVELOPMENT PERMIT Parcel Na: 252304 -9017 Site Address: 17680 WEST VALLEY HY Total. Fes : 419.06 This Payment 255.75 Total ALL Pmts: 41.9.06 Balance: .00 +* *•*• * * *' i1 *• * *4 *AA4r * * ** 4*** A+**• k**• k* * ***** ** *A** *** *** *A.** * * * * **** De scription BUILDING - NON US STATE BUILDING SURCHARGE 9212 "A1 /07 9717, Amount 251.25 '4,50 •t* * * :1t:l ; I f 1 ;t :A* * c :l: *klk:k•h*•+- k *;1i -A h * *A ,if *1'jrh:kcl *1r *::4 °lkk41. * k. CITY OF TUI WIL.A.. 1RAN"Nl:T *k * *h *h* * * *:1 k :4 :1' =. *4A *•A:4h *AN *k*A•rA * * *•A *A*IrAh h:1* *A*A*A*A•A.A •AA TRANSMIT Number: t <9700080 ;Amount: 1.60.31 L2/09/98 1Ca57 Payment Method:, CHCCKI( Notation: THE RONHQVOC ARC tnit: Il.H Permit No D98'-0420 • Type: DEVPERM TDEVI LOPMEtd'f: PE }U4I'f Parcel Mc;. 252304-9017 S i tc Address: 176130 WEST VALLEY HY Total bees: 41).06 1Mria ; Payment 1C3u31 Total ALL Pmts. 163.31 Balance: 2”.75 ******* A* A*** AlSkA****: 1** k* A0/k**** J 1* rlr AA* **** * * * **AA *h *A4** *4 ***•* Account Code 0O0/345..830 Deticr i pt i on • PLAN CHECK NCINRES Amount 163..31•: Pr '&a ,,, ( , e o s e �ioft �/"'' /) A ) '7(8O — (k )v 414r' Da Special instructions: �� Date w n /� 7 9 pm. Reques r: Phone: COMMENT Insp ed per applicable codes. INSPECTION ') RECU Retain a copy with p , mit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ac Tr) .-c^ -/.C Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, f e must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: I Date: Corrections required prior to approval. (206)431 -3670 Pr Oak— i , ) Typ Inspe on / C ' L 7 r ssb0 V kt Date c� l �! q t Special instructions: ti � ✓ 10 O`P V \o Date wantdl e ft 'y _ l � 1 Reques P: � Phon 7d 9, _ ?S63 INSPECTION_RE D Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 C proved per applicable codes. PERMIT NO. (206)431 -3670 Corrections required prior to approval. $4 .00 REINSPECTION FEE REQUIRED. Prior to inspe tion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Receipt No: Date: g jeyt:toYt/1 Wit (? • Ty of lnspecti9nn: re ss: t , �J } Date etl: J 2 Special instructions: e •_- Date w , / cf a.m. P.m. Request Phone ^ , 4_ Li .c7/02_ C INSPECTION NO. INSPECTION RE( D Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tu•wila PERMIT NO. (206)431 -3670 proved per applicable codes. 0 Corrections required prior to approval. COMMENTS: �.� Z.,#45 G ,ccl"2/64 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No: City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name c \ - `C 7""1 Address 1 CUu \)C`, k-\\\ Retain current inspection schedule Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: vvvr.rwey Q Approved without correction notice Approved with correction notice issued FINALAPP.FRM Permit No. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Suite # Authorized Signature Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 C C City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name iN\beAN\34\1 % US () (5 Address \ eA3 \1c‘\\t \-L` a Retain current inspection schedule - Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: :4 Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM Rev. 2/19/98 Permit N John W Rants, Mayor Thomas P. Keefe, File Chief Suite # Date T.F.D. Form F.F. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 0, Phone: (206) 575-4404 • Fax: (206) 575-4439 ?err Ai* Coolti• PLAN REVIEW/ROU SLIP ACTIVITY NUMBER: D98 -0420 DATE: 12 -9 -98 PROJECT NAME: NORTH VALLEY BUSINESS PARK Original Plan Submittal Response to Incomplete. Letter Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: din Division '� Fire revention Planning ivision licWorks ❑ tS ructural yu ❑ Permit Coordinator Complete n \PR•ROUTE.DOC 6/98 DETERMINATION OF COMPLETENESS: (rues, Thurs) Incomplete DUE DATE: 12 -15 -98 TUES /THURS ROUTING: Please Route n No further Review Required Routed by Staff E (if routed by staff, make copy to master file and enter into Sierra) is Not Applicable ❑ Comments: REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 1 -12 -99 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION,: DUE DATE. Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: Dear Sir: City of f Tukwila Fire Department Thomas P. Keefe, Fire Chief Fire Department Review Control #D98 -0420 (510) December 18, 1998 Re: North Valley Business Park - 17620 West Valley Highway The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is, required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 • Page number 2 Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 2. No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.2) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 Thomas P. Keefe, Fire Chief purposes. (UBC 1004.2.2) When two or more exits from a story are required and when two or more exits froma room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112.2. (UFC 1207.1) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 4 Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Thomas P. Keefe, Fire Chief working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) 6. Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 7. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 8. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) 9. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax• (206) 5754439 C CL U7 1 w LL DEPAIUNiliNT 01. I.A11()R AM) iNIA.ISTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ' REG I ST . # EXP • DT CCO1 DDMORCCO55 EFFECTIVE DATE D D MORRISON CONST CO INC PO BOX 2110 RENTON WA 980 5 6 J7 — • — • 1).•—a.l. 1.41 I h.10.ek tow., .th D 11102-R.160L) 6,75 e•v I2 ? rI 21: zik." 12'c9" c.'"- STS. NE .4 ( GREJ"T6D ARSA 1 IREMA11Jp,S S- STo1S E PAGI 131215 ./serfPoX, 1 i 4F lX.r. LOA° = 2 1•OXI R 117 r — L_1 ) 1 .1Et.4 17E1✓11SII.G LIALL U p T r o �o?.LRH •. ENRY USE 6 IL -14 s 1 e I i ac.aiz I4— PGeQ2¢uou o�t Cou 14 e,11IIaO. LI / S /SU G 1<4'6 I,t l Ima9 T1'1 I1:Ecv ..ve 6t<.S VRE Imo _A i F+K 44C4A E F . *Fd7C�TlfS a K 1 9T. U d LL 54 IT 14RL E�lST,1 iAgz.H' U BIZ 2 tz e `t7 (:,d T I R U 1004 ,2 Exf. #4 , r — � '3 fcaat.SPAS_ (s-c . 25.-9" 19.-.9'- ° e�M f ee-P l c, " TYP. WALL 1 -114" RAM -SET CONC- /P1NWa24"O.C- 11.1591,. la�lz evrte CONC. FLOOR ° WALL / FLOOR CONNECTION _2Ce ls2 ° OEMiSING W ALL I.GbiQ FLAW 1 /I4uoppn �cr�- sTtztJG'flJ RE ' Lee , I 6.GATWO uoT ATTAGI-I calA 5 AT oEFLEoTIOti `ng hc.IC LEG II STUD pep. NOT ,0.113 'TYI°e l44 5 /b tl o•TN Sloss :O W L ?of? DGFLE cTIo1J TR,- 11 /W:Il _ yo11 PAR S I✓ kIIII.etelS 2 LE4-AP 12E G IPrioH " 4 " • l t I -_7 1121 _mL Iw'�8 Il 2c9' c2` I i i I � OJEC T {Ja1t U13�; 1.1-11 (SHELL upx. G,:7NST: 5 -0 spRINIcL6D GGat1PANt 1 s -I (NODE -t TE NHZb(zp SITE) le NO ut3t 0 a 6 LJPA.1. Le.'. .24 (AT NE3-d ' ,�3' ) ( /coo 2 ExI15 {aL`Q'D , 3 L'- -XIi'S �T V L. ij '17 •TV ILET pAo l L.171 E . P1Q.a/I oW (sAtvia 1 uua OG.L.UFi 6h151aer c,oI7L HO GHANGSs To 6N ISLL,LIGHTI1 4 G ) HvPG T♦iE S. 3z9.8s FF_FT of THAI P .Li vETNNTFN7 Lo 7 IN SEcrLN 2s Nv211 -I 24J1LTE 4 EaSr, N KINLi- CoLNTY 1,IE4.T. • PVGreT SvvND . 1Z& TIUN, 1- I4rIT 4 P�wEK T!4HT-c* LAY 4ND , x.A.TiE STFRLY of 4\ LINE CvM\\/hYFD To THE SLATE oG - 1446HINLTFzN R,( 1 Nrr.. - 12ECvRDEt7 1/NO22_..IUN4 GW)UN 1`f TECOfCD1NL1._.NV :7427X,3• EXGEPr TkE E/ ;7 IS F£eT rrE l off : 't "A D tiNt2 LtaNE', 'vf ft> 1 .1- --4 H. 5..1�►i H11t�t(� THIS '?Y - _- F L r — r - roPERTY Fs: 1/M1ZY pa.(2Ti.) S \/ IG I N I - Ty !; 4f • CITY OF TUKWILA APPROVED s1-n Q /NoX.LE SHEET CONTENTS: PLAN & DETAILS REVISIONS NO. DATE JOB NO.: 9843 DRALLN BY: TJR CHECKED BY: TJR DATE: 12 - - •8 DESCRIPTION CITY OF DEC - 9 1996 I QrI I I CI1h I, i D'1oqzo 6625 S. 190th St. Suite S -101 KENT, WASHINGTON 98032 (425) 656 -0500 • FAX (425) 656 -0501 c-9 omisswns rc auth the veolatIcn cf . :..! ccde or ordnance. Receipt of c_r. Wor's s rovod plena� a l diIO/w/Jledgec T H E RONHOVDE ARCHITECTS I NC- I TOR —JFfi RGNHOVDE I SATE Cr WASHINGTON I� SHEET NO. Al