Loading...
HomeMy WebLinkAboutPermit D99-0092 - Business Interiors NW - Office and RestroomsD99-0092 Business Interiors NW City of Tukwila � Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 032304 -9164 Address: 10848 EAST MARGINAL WY 5 Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: AOFF DEVPERM 001 North: SEATTLE DEVELOPMENT PERMIT Fire .0 South: .0. ,East: Sewer: VAL :VUE' Slopes: N Contractor License o: SEATTCR101BZ OCCUPANT BUSINESS INTERIORS NW 10848 EAST MARGINAL WY 5, TUKWILA, OWNER MCCONKEY DEVELOPMENT CO 3006 NORTHUP .WY #101, BELLEVUE WA CONTACT STEVE DONA 12425 93rd PL NE, KIRKLAND, WA 98034 CONTRACTOR'» SEATTLE CONST RESOURCES. INC Permit Center Authorized Signature:_ 2' (206) 431 -3670 Permit No: Status: Issued: Expires: Occupancy: UBC: Protection: .0 West: WA-98168. Phone: End End Time: Fill: Time: Public: D99 -0092 ISSUED 04/09/1999 10/06/1999 OFFICE 1997 SPRINKLERED/ .0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of wo I am authorized to sign for and obtain this development permit. Signature: "�/�c9 -� Date: 1g19 Print Name: ` 9 . 1 � ; Cwt 1 S 5 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ct Streams: Phone: Phone: 425- 820 -1753 206- 282 -7500 1.414 .,ELLIOTT AV . W, SEATTLE, WA 98119 k******` k* * * * * * * * * ** * * * .: * * ***** * * * k*******'**** * * * * * *•k * *•k* **** * * ***** *k ***t Permit Description: TENANT IMPROVEMENT TO AN EISTING OFFICE SPACE INCLUDING BARRIER: FREE"RESTROOMS. ALSO, DEMO WALLS * k*• k• k****************************************• k**** k**• k* * * * * * * * * * * *k * * * * *k * * * * * * *kk *' Construction Valuation: $ . 40,000.00 PUBLIC WORKS PERMITS: *(Water Meter. Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS :. ,'.': Fire.:Loop Hydrant: No: Size(in) .00 loud :,Control Zone: Hauling: Start Time: Land Altering: Cut: Landscape Irrigation: Moving Oversized Load: Start Time: - San`i•tary Side: Sewer: No: Sewer Main Extension: Private: Storm Drainage: Street Use: Water Main' Extension: Private: Public: *************'***********:**.*.******************* * *.* *•k * *•k **** * * * * * *** * * * * ** **qtr' TOTAL DEVELOPMENT PERMIT FEES: $ 900.04' *** k**** k*************** k* k***** k***** * * * * ** * * *•k * * * * * * ** * *k * * k**rk *,***4*k*1 k*k, k*** *k**kk * k'kkkk'kkkkk**kik.kkkd kkkkkkkd kkkkFkkkh i'****k,kFkFF Perini t .`Conti i ti'ons 1`,, No'`.changes wi1.1 be niade •to the plans ,unles, approved by t he Er gineer and titie TLi kw11 a Bui 1d„inv D visi i nspec ti on r cov ds Fy ndKapprov'd plans shall be av,'ailable at the jobr^si. °e "pjrior' to ":t e"G �rt�ktt'}yf� an ,y con traction T he �i.?eVment..s etje toAbe mai'nta 'nyerk and avail. „4 ab' u . tit ti saltt :111se p a ii ti ut} t iun ,pp ro Ne 1s gY nt e, le 1a cts ,c.a1 e ",,, i s s he bta•�iner�: thr0,4,5h, the :W V h 1ngtpn State ..:D i v r -ion of,; L r`:2n.d •••• indus tr . i es a0 ar1`i ,re1 ecirr iki a f'..': :' wo w1 • e itrs d by tat "ag ency f C, 4B e. 3 , i t ,�K , fi hs rr . i'• t �i .,� �. Pl:iin►bii7 p�,ec m ts�, � h4l •l .be ob "ta,i d through � the,4,.e g t�tl e i l.o'un l � aefil0,n� c ot P u b11c"+Hea*ti. .,Pluiimbing 1 J be, • in pe d 'y that , gency! = ` n,cru ng: d a1.1 g 'as• pifng, pi 29644' j 1.1 fi n t chan'i al. wwori :sDa beg01.e.t s eparate permi th e / t}r F "t'4 1a ti " , --: -<~ •; a ,, � � ,. u � ,. � �.man , . A11I„°'urtstr ucti',0n t,o ,, be ? ion,er in - , .conforce w ith a p pn Dyed n� pid1 ! arnc regij'fir en►en `� o ttTe 3U n1foc�iii ' Buii,1 i1n+g C'o,de f i�997 E 't ion ate(4 amendedx Uniform _\11 �ci1 ai f i , pal ; ,�.:o e ' (1997 irt -- A . ti ' w � � � vti . Y di ) . ari� a�hrngtcih'�State En gi''kc• de 'Nc199; Ed tian7 i lity o Petmit T,he �1s.suance' uf1a•� r penr nt'of ap prroval of T . gy : 01C ' cit a nj °vlkiputa Yron� rhal1 no be. c`irti`:'r tr d.:,t )b- f a " :p er m tf' t°o�. , ,,Mor an. & e,ppr ~eta 1s' at t . • an y vi o !,t ton t ;\a►h. f ` o +G ': e` *.pt a v 1 i� `i arl r'=o`t t'13,' e bu i 1.1 tgr caci.e o r of¢' arm : • 't , h ` pr d �nance of the .iu i ,di cy� ori , , `' : 1'0 ',�erm,i t .p 'su t �\ • i:v e au thiar�ity tb , •v la t . a r. car.ceirgr ;; prov1,4i.onsJ of rtti, s:� • t�iiN 's.Ita :),1 0. •01 i. • .,. y .h ,z F ',; N.4:?..,-,,, n te y `Status ISC UED: 401 led 0,3122/1999 Issued 04/09/1999 .. ' .•. •.:„ •,, I.., ,„ , , „ ,, . , , . . .. •• . • , . ...' .,• . ...,, _ • . ,,,. , ... •• r'' o . ,. .... • . .., ." , : • - ='''.... . .. +'** A'1*.:k:10 : - ;it il.#4'..ily li'.'lli-fr **.k A- - is •A A '.*:.•?; • J *.k•.7.-:-/s41? '.k• ii tA ;.k., ir ..4• : , '.:. '• ' • .i" 4:0'-:, .:. '': .';:' :;::- -.1 '-':: - :..--"':':...:::.:','. -:. , I PA USA 3:T • .. . . .; **404:11-4; 4 A ik%k ' ''' — . . - ..... -.,-.•,. , . .... - ... „, .. , .• . . . ... ,..„..,,..6iie. , ,t4 .,. i.ti... ,,,. ,: ,..... : .. f . ; .. : • 1 ,,.6''.....•':''i--,:i :i::,..,114'141;,.r:;-: : R. 0 (0046 '41 M 6 1.1.11t c :;1'..2.','t.,::7,.:;:.:.. ,..: • i i.,... :- .. - .• . 7 Y .!$.` .`'.i..-!.'".4',,:.'t.'..-k-',*...**..)t :::::: : - i.: - '''.. ,.,..,.........,..-..--,;,..-......--,...:.-..y...---,..;-.:,;„;:..:„..;;;,........,..........;;;;:s..;:.:,,,...;,,....::„_.....,,,,,....,-,...",..__. ,., ... . , ;,.;,;:::;',.:, (10:1:.,.., 2. ':,.',...--'t}i :;'... DE Y ( E ft M .., DEYE;LOPtitita. ' PER MIT :::.‘;,... iNIO i : ',,••,; •• ...: -... ....',. ,...;.. ,. • ':.''..''':131to'...',AddrOsr..:.10848...'Elitht:A41.411OINAL:.14V fi•' ..• - - ' ' ' ' '', •i.. ‘• -... :::.:•.:',I.h,i 4",...1 : . .' ::5 •' Total (LL. , IIM't4i.'•' . 1,••.:. .. . 9.00f.; 04 —,-..• •■ ' , • .. . .', : .,' ' .• ..1• .' ' ,• . , .. r.• .. • . ' .. .. -.. , • .. • ....:, .. ' . .,. '. . .: :''''''.;.: '''': : ''' ' •i l.. ....; ' .: ' ' '.: ':' . H . . " .....: ..... ' ... -. '.: ' .' ' ' ' ,.. ' . '' . ' . , ..-, •...B.al ant; e . . . - . • :. .. . . ,, 00. , *.**', Irk ffAlfic.A tt:* A * A ***..A-k .A.**464 11-A4.A :It A• * 4 iv.k:7 3-**4 .11. 4.4 It- A .a • 7c • 14. .4.. A * * * * 'A .* A. -A * 46.i.jatt'6 i Code • '...: 2 .• 1Yep.cr.:i'pt.iori'.• •.• ••• - , .. • • 'Amount' • 006/6 i00 • •.• ': .. '..13Iii Lbi NG .• NO.NI3E3 .• '.', . . — ..- ,•!-. 542.75' 0,90/38 - . , ..: -:. ST AT:E ...,',BUY;LP.Ififi. -.SURCHARGE ..', '. '.,.,:4;50 . . • .• 2296 04/12 9717 TOTAL 547.25 • ••• , • • • : " • **)‘..:*4.:t:" * b* 1" R. R800017 Amount. 03122199 • .'.:13USI 1)1 E h • GIN • 04 ta1 :•:141..1.-*' Prnt 32 "3 • • .54725:', * * * * * * * * * * * * * k*, .k* * * * • • .".Descr • N 0 N It E S • • , ■ • •, • 1738 03/23 9717 TOTAL 352.79 ' Project Name/T nant: / �J!'d /CGS 4rhaela�s AL Existing use: DI Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel p Office ❑ School /College /University ❑ Other Val a of Construction: d1 p s0. etc. Site Address: City State /Zip: Fg,E►lcef r_ q I 1 i " Pro erty Owner: K. 78�b$ Phone: Street Address: .0'4110 eiRfi i° .19r SvIT& icy ��tate /Zip: Yaa wA Fax #: Contractor: 715 001 Phone: Street Address: City State /Zip: Fax #: Architect: S J po Af2C./i176c4c! eG on 4Z gab 17....S t Str et Address: '/ Iztee C 93 4 30 eik-e, pia City State /Zip: robin (sit ax 4 F' f�elill L) Engineer: .9,8 Phon s4t1G Street Address: City State /Zip: Fax #: Contact Person: 7;4074. 7El/6 Phone: Street Address: City State /Zip: Fax #: Description of work to be done: l 9 R A ve'G R 7 fj�. S - pen v 4.9k (,G, S J 7NtlAd 7 J fl• ewiz ' 1 l '/ 7 A r) F>4:37.11 4�A16- i!'r9Cs Existing use: DI Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel p Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse r:1 Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Fil Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes p. no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes ❑ no Existing fire protection features: Ft sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: A C44tt44 ' existing Area of Construction: (sq. ft.) . , Sea Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Commercial / Multi - Family Tenant Improvement / Alteration Permit Application CITY OF TIP'WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date aplylsatio=1: Date Er ca�e�es:�..�� Ap tik r5ken by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM CrPLRMIT,DOC 1/29/97 ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: BUILDING OWNS R TH R/ZED A ENT: Signature: Date: 2 z Print name: 7-a' r 4 • lo e: • 20 7 - Fax II: Address22 ��go pzdoczy Al g City /State /Zip l gK. _ i UA ALL COMMERCIAUMUL TI-FA A Y TENANT IMPROVEMENT /ALT -ATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a.change in the amount of plumbing - fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) - 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved, 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site El ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY F THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPI:R1111T,DOC 1 /29/97 Project: 5 ..—.— 4J -c Type of Inspec To'63 -- "/ Ayliosy cr.,. _ ......... ft. M/240 . cgate called: Special instructions: Date wanted: 6 Requester: Phone: INSPECTION RECORD Retain a copy with permit INSPECTION No. : CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per codes. Corrections required prior to approval. PERMIT NO. (206)431-3670 COMMENTS: e Le (45 /7 • (-6a- M 7r2 9 / • 14 b--/-3\c s rni ), Li 4e64 S pv 0 .eLd 111 List $47.00 REINSPECTIONfE REQUIRED. Prior to inspection, fee must be paid Receipt No: Date: at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD; Retain a copy with permit. INSPECTION NO. • - CITY. OF TUKWILA BUILDING DIVISION • 6300 Southcenter BlVd, #100, Tukwila, WA 98188 • (206)431-3670 .Apkoved.perapplicable codes; .•• 0 Corrections required prior to approval. COMMENTS: ,z() 409-getee,/ ftsc; roc, T7 Ccif ‘7. 7zA efi 1.1 hf )7- -- Lt e 'rgnr ey,(0-rizy 1]( 4-"44f 0 $47.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: p j Ty of Ins ectioti: ere ..-- • Date c led: • Special instructions: P.m. Pi c :p6 7..... ... 7 4 ., l INSPECTION RECORD; Retain a copy with permit. INSPECTION NO. • - CITY. OF TUKWILA BUILDING DIVISION • 6300 Southcenter BlVd, #100, Tukwila, WA 98188 • (206)431-3670 .Apkoved.perapplicable codes; .•• 0 Corrections required prior to approval. COMMENTS: ,z() 409-getee,/ ftsc; roc, T7 Ccif ‘7. 7zA efi 1.1 hf )7- -- Lt e 'rgnr ey,(0-rizy 1]( 4-"44f 0 $47.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pct: .. i Type of ecti s -71 pedal instructions: Date wanted; 1°91(4°.-.11, R Z r Pho7i /vs I f e9.45(0 Approved per applicable codes. INSPECTION RECORD • Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd, #100, Tukwila, WA 98188 Now, ... ' ""*" • •4 „ . . OR Corrections required prior to approval. COMMENTS: ) ab7 77-7 etOt .4E r.o4il 4 1" .2) ileled 4, 4k7z)i-t} 4 -4.. Mad-d 4 4 t4' 0, J9W+t-n 164 - El $47.00 REINSPECT' • FEE R QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: .to3t0m.r. WV.WPAV/a144 4144 • '.1iVlillefFi'd4Vi,t41"11., W. PERMIT NO (206)431-3670 !rojeA /At m • TIof,inspectiod: ,. 11/ c.:Az4 Ad z... / 9/ 6 i ,.. E-i t i -Date called: 5 --/ - d ■ .... ...e.r , "..... \ Special instructions: • - • -,, ss.., Date wanted:/,/9 i 9 P.m. Requesteril 1 w Phone: A)647/4 • INSPECTION RECORD Retain 'a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 7'6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NC04_ (206)431-3670 A pproved per applicable cOdes . tagLorrections required prior to approval. COMMENTS: c-rits>7(./ t.r/2, d/c A65 /0 a,,0 72ch o /ZIS SI 7'(.Cizg 7 ,7e (Y(G Date: 5 6 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pr t: k ic i fA AA t,t,.• Type of Ins I ec‘ , , . tr7 ..."■Il V Ad d rrlyezig 6: fil D ate called: 5 A,„ /9 Special instructions: J Date wanted: . 67 / c at) P.m. Requester: Pm .INSPECTION RECORD • Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300iSouthcenter Blvd, #100, Tukwila, WA 98188 , • . • ' • ' • .• 00-00 g-- PERMIT NO. (206)431-3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: • DI $47.00 REINSPECTION : REQUIR ED: Prior to inspection, fee must e paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • ' • City of Tukwila John W. Rants, Mayor Fire Department Thomas P Keefe, Fire Chief ,Project Name C/ $'i /1d // F �1 iC /? 'Address' e' ,f )1 (t-) ' schedule:... Permit No. Suite .# Retain current inspection Needs shift inspection ,‹ Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: / f Authorized Signature 2INALAPP . FRM ($4,./ /c/ Dete Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754449 April 14, 2000 Steve Dona 12425 93 Place NE Kirkland Wa 98034 City of Tukwila Department of Community Development Permit Status D99 -0092 10848 East Marginal Way S Dear Mr Dona: In reviewing our current permit files, it appears that your permit for a tenant improvement, issued on April 9 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, j Bill Rambo Permit Technician Xc: Permit File No. D99 -0092 Duane Griffin, Building Official Steven M. Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206.431 -3665 March 26, 1999 Steve Dona Steven Dona Architecture 12425 93rd Place NE Kirkland, WA 98034 Dear Mr. Dona: City of Tukwila RE: CORRECTION LETTER #1 Development Permit Application Number D99 -0092 Business Interiors Northwest 18848 East Marginal Wy S The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit two (2) copies of each document. John W. Rants, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. The following corrections need to be address: Building Division: Contact Bob Benedicto, Senior Plans Examiner, (206)431 -3676 regarding the following: 1. Show compliance with Uniform Building Code 1106.11.2 and 807. At this time, the Fire Department, Planning Division and Public Works Department have no comments regarding your application for permit. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 ACTIVITY NUMBER: D99 -0092 PROJECT NAME: BUSINESS INTERIORS NW Original Plan Submittal Response to Correction Letter # DATE:. 3 -22 -99 Response to Incomplete Letter Revision # After Permit Is Issued DEPARTMENTS: B ildin Division o uec -z3 Public Wokk ❑ Fire Preventi.on 400 3-Z Structural T tb4=Wci PLAN REVIEW/ROU SLIP DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 3 -23 -99 Complete tl Incomplete ❑ Not Applicable ❑ Comments: TUES /THURS ROUTING: Please Route �. Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions ❑ UW&4 W Waled REVIEWERS INITIALS: CORRECTION DETERMINATION: Approved E Approved with Conditions ❑ \PR•ROUTE.DOC 6/98 Planning Division ❑ Permit Coordinator a No further Review Required a DATE: DUE DATE: 4 - 20 - 99 Not Approved (attach co nts) 02.4 DATE: DUE DATE: Not Approved (attach comments) ❑ REVIEWERS INITIALS. DATE: Date: 0 Response to Incomplete Letter 14,1 Response to Correction Letter 0 Revision after Permit Issued Project Name: 73 S•444 Cal 1\1694t4 e CS7 Project Address: e 'K024441- £i,ij4. S Contact Person: 1/44— Phone Number:CO..5) 42° 1 Summary of Revision: — i £4 t4J . .1)i6- 12fg Ardidib Sheet Number(s) RECEIVED eitY "Cloud" or highlight all areas of revisions and date revisions. Submitted to City of Tukwila Permit Center Entered in Sierra on CITY OF OF TUKWILA Department of Community Development Permit Center 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670 Plan Check/Permit Number: 1)99 — 0 e APR - 7 1999 pErour (ENTER 3/4/99 Subject: Northwest Pages: 1 of 2 Thanks, Sincerely, Steven Dona A na Wednesday, March 31, 1999 TO City of Tukwilla Fax (206)431-3665 Attn.: Mr. Bob Benedicto Senior Plans Examiner From: Steve Dona Revisions to T.I Permit #D99-0092 Business Interiors Enclosed: Revisions to Restroom/Shower plan showing tile flooring and sidewalls and showing 5'dia wheelchair turn-around in shower area. (as per our phone conversation). Remarks: Bob, Please give me a call if you have any questions about this revision. ven hitect and Planning 12425 93 4 place N.E. Kirkland, Washington 98034 (425) 820-1753 ApR - 7 09 rr NOTE: PROVIDE TILE FLOORING IN ALL RESTROOMS AND SHOWER ROOM INCLUDING SHOWER PAN. SLOPE SHOWER PAN NO MORE THAN 1/4" PER 1' -0" SCALE: 1/4" = I' -O" CONTROLS ON SIDE WALL REACHABLE FR/ SEAT SIDE WALL 1 1 I Ii !' I 2T ' 1 1 1 SOAP DISH TILE TYP. m OPTIONAL / FOLD DOWN SEAT ROLL IN SH0V4!R SCALE: 1/4" = I' -O" NOTE: SHOWER PAN MUST BE FLUSH WITH FINISH FLOOR (NO THRESHOLD) BARRIER FREE RESTROOM S T E V EN ARCHITECTURE & PLANNING 12425 93RD Place NE Kirkland, WA 98034 Phone: (425) 820 -1753 ADJUSTABLE HAND HELD SHO. HEAD ON FLEXIBLE HOSE BACK WALL ifs/ BUSINESS INTERIORS NORTHWEST TUKWILLA, WA m 54" OM NS E NOTE: PROVIDE TILE FLOORING IN ALL RESTROOMS AND SHOWER ROOM INCLUDING SHOWER PAN. SLOPE SHOWER PAN NO MORE THAN 1/4" PER I -O " 6008 STE SCALE: 1/4" = I -O" o t -n0 m Cm li �o G STERED ARCHITECT E P. DOHA STATE OF WASHINGTON // CONTROLS ON SIDE WALL REACHABLE FR/ SEAT SIDE WALL SAIRRIER FREE .ESTWOM S T E V EN A R C H I T E C T U R E & P L A N N I N G 12425 93RD Place NE Kirkland, WA 98034 Phone: (425) 820 -1753 ADJUSTABLE HAND HELD SHO. HEAD ON FLEXIBLE HOSE BACK WALL OPTIONAL FOLD DOWN SEAT ROLL IN SHOWER SCALE: 1/4" = I -O" NOTE: SHOWER PAN MUST BE FLUSH WITH FINISH FLOOR (NO THRESHOLD) BUSINESS INTERIORS NORTHWEST TUKWILLA, WA Fire Department Review Control #D99 -0092 (512) Dear Sir: C= City of Tukwila Fire Department March 26, 1999 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Re: Business Interiors Northwest - 10848 East Marginal Way South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 3. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Page number City of Tukwila Fire Department representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-44,39 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax: (206) 5754439 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL 7REGIST ' #_ = _-'EXP. ' DATE: CCO1 ? ' S EATTCR101!W10 /17/1999: EFFECTIVE DATE W 01/09/1990: _ 3 ,.- =')„ - .... • - ''. .t 3 L y r•_•. Y�i« ° «/ SEATTLE CONST RESOURCES INC 1414 ELLIOTT AVE W SEATTLE WA 98119 6 LJ GENERAL NOTES L ALL WORK. SHALL CONFORM TO APPLICABLE CODES, INCLUDING BUT NOT LIMITED TO THE 1994 L61IFOR'1 BUILDING CODE, THE 1994 WASHINGTON STATE ENERGY CODE, THE 1992 WASHINGTON STATE BUILDING CODE, CHAPTER V -20 AND V -21 WAC, THE AMERICANS WITH DISABILITIES ACT, AND ALL RILES, REGULATIONS AND ORDINANCES OF THE GOVERNING AUTHORITY. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, AND SITE CONDITIONS, AND SHALL NOTIFY THE ARCHITECT IMMEDIATELY IN WRITING OF ANY DISCREPANCIES, ERRORS, OR OMISSIONS PRIOR TO PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS FOR CRITICAL DIMENSIONS. DIMENSIONS ARE SNOU.N TO FACE OF SNDS UNLESS INDICATED OTHERWISE. THE PROJECT SHALL BE SCHEDULED AND INSTALLATION OF ELEMENTS COORDINATED AS NECESSARY TO PERMIT WORK BETWEEN DIFFERENT TRADES TO PROCEED WITHOUT UPSETTING PROPER CONSTRUCTION SEQUENCES OR DELAYING THE PROJECT SCHEDULE. PLUMBING, ELECTRICAL AND MECHANICAL CONTRACTORS SHALL VERIFY ALL REQUIREMENTS FOR THIS PROJECT AND COMPLY WITH ALL LOCAL CODES, SUBMIT PLANS FOR APPROVAL AND OBTAIN PERMIT BEFORE STARTING WORK DO NOT VARY OR MODIFY THE WORK SHOILN WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT. DETAILS WHICH OCCUR BOTH RIGHT - AND LEFT -HAND ARE 6HoWN ONLY ONCE. TYPICAL DETAILS ARE NOT REFERENCED AT ALL LOCATION. THE INTENT 16 THAT THEY CARRY THROW BOUT THE PROJECT UNLESS OTHERWISE NOTED. ALL REQUIRED SHOP DRAWINGS AND SUBMITTALS SHALL BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK ALL SHOP DRAWING DIMENSIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR GENERAL CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY HIMSELF OR OTHER TRADES. EXISTING BUILDING TO REMAIN J • EXISTING PARKING AREA AND LANDSCAPING TO REMAIN UNCHANGED EAST MARGINAL WAY (STATE HIGHWAY 5 -M) SA'MI NG 5`1•s0L5 S I TE PLAN SCALE: I "•40' -0" REFERENCE TO DETAILS CALL OUT SYMBOL USED ON CONSTRUCTION PLAN NUMBER ABOVE - DETAIL NUMBER OR LETTER NUMBER BELOW - SHEET NUMBER PROJECT NOTES PROJECT NAME: PROJECT ADDRESS: GOVERNING CODE: ENERGY CODE: CONSTRUCTION TYPE: OCCUPANCY: SITE AREA: NOTE: NO CHANGES ARE PROPOSED TO EXISTING SQUARE FOOTAGES OR TO BUILDING PERIMETER CANER: TENANT: ARCH IT!GT: BUSINESS INTERIORS NORTHWEST APPROX. 10838 EAST MARGINAL WAY SOUTH TUKWILLA, WA 98168 UNIFORM BUILDING CODE WASHINGTON STATE ENERGY CODE III -N (FULLY SPRINKLERED) 52 UNCHANGED McCONKEY DEVELOPMENT COMPANY 3006 NORTHUP WAY, SUITE 101 BELLEVUE, WA 98004 (425) 889 - 1180 BUSINESS INTERIORS NORTHWEST 10838 EAST MARGINAL WAY SOUTH TUKWILLA, WA 98168 LEGAL 1,!SGRIPTION BEGIN(. AT THE POINT IN THE EASTERLY MARGIN OF EAST MARGINAL WAY AND THE SOUTH LINE OF SECTION 5, TOWNSHIP 25 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY WASHINGTON, SAID POINT BEING 811.792 FEET, MORE OR LESS EASTER, OF THE SOUTHWEST CORNER OF SAID SECTION, THENCE SOUTH 88 20" EAST ALONG SAID SECTION LINE 524.788 FEET, MORE OR LESS, TO THE WESTERLY BOUNDARY LINE OF PUGET SOUND POWER AND LIGHT COMPANY RIGHT OF WAY, FORMERLY SEATLE TACOMA INTERURBAN RAILWAY RIGHT OF WAY, THENCE FOLLOWING SAID WESTERLY BOUNDARY ON AN ARO OF A CURVE TO THE LEFT HAVING A RADIUS OF 2814.93 FEET AND THE LONG CHORD OF WHICH BEARS NORTH 0 WCST 359.985 TO A POINT OF TAHGENCY; THENCE CONTINUING ALONG SAID BOUNDARY NORTH 21 53' 50" WEST 53350 'i-ECT TO A POINT ON A CURVE - BE"NCE ALONG SAID BOUNDARY ON THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 2914.93 FEET AND THE LONG CHORD OF WHICH BEARS NORTH 16 ° 28' 55" VAST 551586 FPT TO THE NORTI, MARGIN TO PLACE OF BIGINNINS; EXCEPT THAT PORTION DESCRIBED AS FOLLOWS: COMMENCING AT A POINT OP THE EASTR( -T BOUNDARY L. OF EAST MARGINAL WAY, SAID POINT BEARS NORTH 16 50" WEST 1557.128 FEET FROM THE POINT WHERE THE SAID BOUNDARY LINE INTERSECTS THE SOUTH BOUNDARY LINE OF SAID SECTION 3; RUNNING THENCE SOUTH 16 30" EAST ALONG SAID EAST MARGINAL LNE 192329 FEET; THENCE SOUTH 89 NO EAST 232.103 FEET TO A POINT 70 FEET DISTANT FROM THE CENTER LINE OF SEATTLE TACOMA INTERURBAN RAILWAY; THENCE ON THE ARC OF A CURVE HAVING A RADIUS OF 2954.93 FEET ALONG THE WEST BOUNDARY LINE OF A CERTAIN LINE AND PARALLEL TO SAID CENTER LINE, THE LONE CHORD OF WHICH ARC BEARS NORTH 13°24' 13" WEST 189.402 FEET; THENCE NORTH 89 50" WEST ALONG THE SOUTH BOUNDARY LINE OF A CERTAIN PRIVATE ROAD 243.SM FEET TO THE PLACE OF BEGINNING. i�fi�f�V�tl NG I N!X A -I SITE PLAN 4 PF + -..T NOTES A -2 CONSTRUCTION PLAN AND DETAILS STEVEN DONA ARCHITECTURE AND PLANNING 12425 931RD PLACE NE KIRKLAND,WA 98034 (425) 820 -1153 coat of appiwed G'I* 7 ) B° ► (1- Data r 19 1 `l 4, SEPARATE PEP " "!T R. rt_D „ MACHANIC;,L itrEJ I�PLUMBiNG ❑ GAS PIPING CITY OF TUKIN LA BUILDING DIVISION "TTY Cr TU11WILi APPRCPED APR f;7SO "r?: cJ SCOPE i TENANT IMPROVEMENT TO AN EXISTING OFFICE s'.'.:,. ;: ;T cTcra and omissions 17.7d ; - -- ... SPACE piar.; +ices not authorize the violaticn of z-.y AREA IS ALAEAAY OFFICE USE PROPOSED AREA OF REMODEL IS 2220 S.F. *- adapted GCd4 M Oldi=lOR pt Of contractor's S T E V EN PROJECT NAME NA A R C H I T E C T U R E & P L A N N I N G 12425 93RD Place NE Kirkland, WA 98034 (425) 820 -1753 MOBILE (425) 466 -9197 BUSINESS INTERIORS NORTHWEST TUKWILLA, WA DRAWING TITLE S I TE PLAN FRO.1ECT NOTES DATE 1 -10 -98 DRAWN BY STEVE DONA CHECKED BY SD FILE: .1.106/51N-S1 TE REVISIONS Al Dcil-ooTI— RECEW CIN CF TUK wILA ilAR 2 2 1949 PERMIT CENTER (2. z w NOTE: PROVIDE TILE FLOORING IN ALL RESTROOMS AND SHOWER ROOM .NGLUDING SHONER PAN. SLOPE SHOWER PAN NO MORE THAN 1/4" PER l'-0" RI GiS.TERED ARCHITECT STE E P.___00 A STATE OF WASHIPiGTON CONTROLS ON SIDE WALL REACHABLE FR/ SEAT IN SHOVES 5ARRIES FREE RESTROOM SCALE: 1/4" = l'-0" NOTE: SHOWER PAN MUST BE FLUSH NTH FINISH FLOOR (NO THRESHOLD) S T E V EN CITY OF TUKWILA APPROVED APR 0 7 1999 AS NO ED ARCHITECTUR13 & PLAN 19 N G nt-fil-DrNG C"; 12925 9381) Place NE Kirkland, WA 98034 Phone: (425) 829-1759 ADJUSTABLE HAND HELD SRO. HEAD ON FLEXIBLE HOSE BACK WALL OPTIONAL FOLD DOWN SEAT BUSINESS INTERIORS NORTHWEST TUKINILLA, INA SCALE: 5/4" = 1' -0" EXISTING T -BAR SUSPENDED CEILING WITH 2x2 GRID REPAIR OR REPLACE AS REQUIRED TO MATCH EXISTING SHEET METAL SCREWS ® 24" O.G. TO ATTACH TOP RUNNER TO T -BAR CEILING EXISTING 2x2 CEILING TILES REPLACE AS REQUIRED 5/0 TYPE X GYB EACH SIDE 2 1/2 x 25 GAGE STUDS ® 24" O.G. TYPICAL 25 GAGE RUNNER TYP TOP AND BTM. POWER ACTUATED FASTENERS co 24" O.G. INTO EXIST.G SUBFLOOR BASE TRIM TO MATCH EXISTING TYPICAL. NEIN WALL EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED NEW WALL TO BE CONSTRUCTED kNALL LEG!N9 CONSTRUCTION PLAN SCALE: I /8" =1 -O" SCALE: 1/4" = 1' -0" NOTE: REPLACE OR CLEAN CLG. TILES WHERE NEEDED. CLEAN OR REPLACE LIGHT LENSES WHERE NEEDED. MODIFY HvAC, SPRINKLERS 4 LIGHTS AS NEEDED. PATCH 4 REPAIR WHERE DEMO /CONSTRUCTION OCCURS. KEEP ALL EXISTING WALL COVERING UNLESS DEMO /CONSTRUCTION REQUIRES PATCH/REPAIR /AND PAINT. REPAINT ALL EXISTING WALLS CURRENTLY PAINTED. REPLACE ALL EXISTING CARPETING WHERE THERE 15 EXISTING CARPETING. CONTRACTOR TO BID ON CARPET INSTALLATION, BASE 4 ADHESIVE. EINW WILL FURNISH CARPET. 6" BACK SPLASH PROTECT PLUMBING TRASH �o)$pE MEcM4t4I( 4 JENti :AT ' rot Tatgr Promfrkie tee iz .0 A A A2 SARRIER FREE i7 TAILS SIDE WALL X 2"1" TOILET TISSUE DISPENSER NOTE: CENTER TOILET IS FROM WALL BACK WALL OL.L. I N SHOlist!R SARR I ER FREE R!ST ROO A2 NOTE ESHO'NER PAN MUST BE FLL'-. - '•N!iH FINISH FLOOR (NO THRESHOLD) GRAB BAR ADJUSTABLE HAND HELD 5 HEAD ON FLEXIBLE HOSE CONTROLS ON 510E WALL REACHABLE FR/ SEAT GRAB BAR OPTIONAL FOLD DOWN SEAT DRAWN BY STEVE DONA S T E V E N A R C H I T E C T U R E NA & P L A N N I N G 12425 93RD Place NE Kirkland, WA 98034 (425) 820 -1753 MOBILE (425) 466 -9197 PROJECT NAME DATE 5 -16 -9G REVISIONS . BUSINESS INTERIORS NORT('W]EST �UKWI DRAWING TITLE ONSTRUOTI O'N f:1-.il `l FILE: 99O6 —BIN /O —PLAN RECEIVED [`ITY (1F TIIKWLA PERMIT CENTE ^: DV DCP7-