HomeMy WebLinkAboutPermit D99-0093 - City of Tukwila / Municipal Court - Security Window and DoorsTukwila City Hall City of Tukwila aePrI nfed OF DI Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 359700 -0282 Address: 6200 SOUTHCENTER BL Suite No: Location: Category:_ AOFF Type: DEVPERM .. Zoning: 0 Const Type: Gas /Elec.: Units: 001 Setbacks: North:, South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: Y Contractor License No: OCCUPANT TUKWILA CITY HALL 6200 SOUTHCENTR BL, TUKWILA, . WA 98188 OWNER CITY OF TUKWILA 6200 SOUTHCENTER BLVD, TUKWILA WA 98188 CONTACT TOM PULFORD 6300 SOUTHCENTER BL, TUKWILA, . WA 98188 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** _ Permit Description: SECURITY WINDOW & DOORS__FOR TUKWILA CITY HALL COURT CLERK AREA. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation:. $ .. 6,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N . .. No: Flood Control Zone: N Hauling :. N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: _ Sanitary Side Sewer:._ N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N . Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 211.16 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:_ Signature: Print Name: � Gichar--son DEVELOPMENT PERMIT Occupancy: OFFICE UBC: 1997 Fire Protection: SPRINKLERED East: .0 West: .0 Permit No: Status: Issued: Expires: Streams: ,. 2 Phone: Phone: 206 - 433 -0179 Size(in)• _ .00 End Time: Fill: (206) 431 -3670 D99 -0093 ISSUED 09/03/1999 03/01/2000 Date : 01 1 0 al I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development perm i a t � y !JG �L L1 - - - Date: 1 - 'I 0 ' 0 ) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 359700 -0282 Address: 6200 SOUTHCENTER BL Suite No: Location: Category: AOFF Type: DEVPERM Zoning: 0 Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: Y Contractor License No: Permit Center Authorized Signature: Occupancy: OFFICE UBC: 1997 Fire Protection: SPRINKLERED East: .0 West: .0 Permit No: Status: Issued: Expires: (206) 431 -3670 D99 -0093 ISSUED 09/03/1999 03/01/2000 Streams: 2 Phone: Phone: 206 -433 -0179 OCCUPANT TUKWILA CITY HALL 6200 SOUTHCENTR BL, TUKWILA, WA 98188 OWNER CITY OF TUKWILA 6200 SOUTHCENTER BLVD, TUKWILA WA 98188 CONTACT TOM PULFORD 6300 SOUTHCENTER BL, TUKWILA, WA 98188 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: SECURITY WINDOW & DOORS FOR TUKWILA CITY HALL COURT CLERK AREA. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 6,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * ** * * * * * * ** * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 211.16 ********************************************************** * * * * * * * * * * * * * * * * * * * * * ** * * ** �..� Date : s5 � I hereby certify that I have read and examined tT is permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performan e of ork. I am authorized to sign for and obtain this development t. Signature: , L Date: Print Name: t S 1 � ' t ' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. �i0,f1 , Op: 0 JTHCEN 1 ER I;1:' Penn 1 r 4 LA N t:rli9, enanit VU t'rEVPER!"! i X661 ieti � 03 3 199 1.999 on G ! ,}( J59! t14.r 0 2ii .�. al• t 09 /it{ 1 / 1 9 444.s4h4 44444 444' 4*4Nkkh 44444444. Mk. 44444444444444444::44 4444 E a,r m l t t.torrd:i t i on . 17e ides `'wt i 1 he :rnatie':to .:,• r. i 1an,: uel I eq., aul.�r~ov . tfi t? t `rE ineer iii . 0i t` h e rsui;wi : i if3 1,.1 e,I • l 1 a • to i r fi,,l on 'recor anti .pp p i a Ma ! 1 : a. r3# lain1 at t t) ; e,;�ioU► mite cir .ior o tiy' 0ar t nv con ., rh.ee, .e'.dt, *cat e 'to oe Atk n ta anti avfal 1- • xat� u 1;. ina,( e c? � ' io rl r ap e r ova 1 :, is gr, nte T tonstr. ct,'(tvfl tFo }idoni? 1 ciint0f aiI' tia 'D 0V o Mans :and :x_! {euu 1 r ,i1 }0t' 'ot theAn i d o n( 3u3 d i n Cod 99 e ( 17 d.l i$aniendteCi li.rol-onr Co cie f'] t-, Edt;tlon) tt i1 W `I f ' n a o ; •' ,.. . , :e n e n o va t ' a t � ; e. 4 1 Y 7 Ed 4, V a i l0A, of P Yati t Tl e l s. ,O.n.c.eeZ01 a ver ml t Or aopr ov�•s 1 kot ar.3 {s. pec.i1 :l:ca.t�io.ns and rliO t.s. tziil utt ti ••anaFil.' not e corn tr ue.iix'; be' a : per mi te. •tkor t ' o ; r arl'' o t , nv ' 1 I:a41Glti o f ann : p +�Ii'sionYti oi. ..the`..,Guiiti code:. or .,oT..any , ut o r "d1n`cit ., o tit 1u7 7 i'40 'L)er`mi 0 ) : 'e Um,1II,l to rxiaV,01:0.0.0..i4,61; t V : - :to violate -`QQ :carrte'i th •p o4,r, ion_ Mirk •ittii� ._�rrefi ; na 1 1' he v (Jr. ,"'r: j • . , _ COMMENTS: Type of I pection: 11 D or at" Cr) lxr - 1 - (I .(._ C, Mtn 4e . 60 V/\n pcOQ 1e C'C'U i.A't Date wa f � / � D/ 1 3 C _ -ea r Op er i v,D U Y1 t) 4 03.3,1.3 �,. PlvI 41 / 1 'e p\4vnS . • UF/ 10 Phone: , ex-k. Itolfq Project: Type of I pection: Address: e l , , 1 C( u l :` a.rc.iA- Date called: Ilg10 1 Special instructions: t Date wa f � / � D/ a.m p.m. Requgger: OM Phone: , ex-k. Itolfq INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY. OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd, #100, Tukwila WA 9818 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Jaz. Inspector: Date : fee $47.00 REINSPECTION FEE REQUIRED. Prior to i ns p ectio must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Projet - • Type of IpspeFtioni , tOZA V i , i + , r---r w t UT: ( t) K... Icl . 140Lthp . ..1d 4 c o lso o Date . . ca lied: urzo-00 . • Special instructions: . - ... ‘. :.. . , Date wanted:Lt —7r-r0 Requester;_myy„_.1 Phone: \x„ 1 c INSPECTION RECORD Retain a copy with permit- , .4 • •.:. • , INSPECTION t'10; t • . , PERMIT NO.: C ITY BUILDING DIVISION, .• • • •.6300 Sbuthcenter Blvd; #100, Tukwila WA 98188 (206)431-3670 ••!'-; , . Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1u-it.( /44i [a mo Inspector: Date: Li 2D 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project Name/Tenant: Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel L,❑ OfffCOL4Jr 71 School/College/University Other C C 14 -L-- Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family 11 Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /Universiitt Other Cf f -L Cuc Value of Constructio If yes, extent of change: (Attach additional sheet if necessary) Site Address: 6 2203 so � Gfu fZ��,l -vo City State /Zip: Tax Parcel Number: `659 700 ”0263 Z— Property Owner: Ct c1 ., ,t_, `Ln Phone: tf 273,0ii1 Street Address: ^ (!1 200 c i , '� ry, 1 3LVD ( City State /Zip: Fax #: �,� _36 J � Contractor: Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person" rte , r PPR w 1910 t ^ Phone: (.4-2; ,0 r. Street Address: City State /Zip: Fax #: c_ ( r3cG? Description of work to be done: 5QcLt (Al I k ice. POdZ$ PO- -ruk4l ( c i1 11a-t.. ccuu0 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel L,❑ OfffCOL4Jr 71 School/College/University Other C C 14 -L-- Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family 11 Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /Universiitt Other Cf f -L Cuc Will there be a change of use? ❑ yes l:�l. no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 3 no Existing fire protection features: &sprinklers A 4446ffiatic fire alarm ❑ none ❑ other (specify) Building Square Feet: L c)U 3. F existing Area of Construction: (sq. ft.) L l q C. C. Will there be storage of flammable /combustible hazardous material in the building? ❑ yes SI no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKI "'ALA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST. FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ ❑ Fire Loop /Hydrant (main to vault) #: ❑ Land Altering 0 Cut ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): ❑ Hauling Curb cut/Access /Sidewalk ❑ Flood Control Zone Size(s): cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date 1c �pled„ Dale apple ex i ...CA Appllca to y: (inItlals) PLEASE SIGN BACK OF APPLICATION FORM crpE <MIT.DOC 1/29/97 BUILDING 0 4 ;, - OR AUTHj. j�. •: , G T: Signature: ,er I I _ Date: � lS i 14. i e Print narne: , I t.O.S ?t, 1 rCk, Phone:43.y 0 I, /ci Fax #: "..2 1 ` _3 r• Address City /State /Zip ALL COMMERCIAL/MULTI -I- ILY TENANT IMPROVEMENT /A ERATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED Complete Legal Description Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ fa Floor plan: show location of tenant space with proposed use of each room labeled ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ M Map showing location of site Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. a Indicate proposed construction of tenant space or addition and walls being demolished Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the properly owner authorizing the agent to submit thls permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. CT7'ERMIT.DOC 1/29/97 • TYFL1UOULA..; ItANSMIT.'Nuatier:' R9B00 43 Amount : i j J i 09/ 14.1:P'j l'a4ment, :Method PAYN'T NcitNt ion:: ram PULF0110 Ini 1 : fLU TR(INSMJ! Permit to 099-0093 Tvoe: DEYPERM DEVELOPMENT PERmIT Pitrce I' tla : 359700 lhia Payment IrA**0.4v4c4c****4****ilic4ici.A* 4r0..A7Iiticit"ti—h3 AtWrikielk******Itici%Oci‘4ek*.h*Isic4.icit Site .Addresst t200 SOUTHCENTER 8L iota! ALL Pats: ealancet x 211.16 21i.lf, .00 Account Co Oe ' qirlotion Amount , I 000/32:!.100 BUILDING - NUNRES 000/345.830 PLAN CHECK - NONRES G1.-it 000/3E .904 ,S1 ATE BUILDING SURCHARGE 4.50 , ................“_---_-....-----.--.... et'7\a/r9c 503 Zucisc.,+ .303 CO t-/ IciD q-3-qc1 Y • • 6914 09/14 9717 TOTAL 0.00 ' Projec ---- Type of Ipspe Lion: l" � , ' 4- , —I v�..� .-N ` $ ..,1.17;4 ( I i tju j Cf ddres ,) 1. .... ,i.... ..., Date called: ,..r ,, }�,/, Special instructions: Date wanted: 77�'` I -� a.m. L 't L.(, - V Requester:_. k _ �r y;, 1 (..2 l r Phone: 1 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit IIVSPECTIOIV IJO.` ITYOF TUKWILA BUILDING DIVISION 300 Southcenter wil ` Blvd, #100, Tuka, WA 98188 PERMITNO, (206)431 -3670 Corrections required prior to approval. COMMENTS: 6 /0 C> 1710AJ or 47 P. EVE. Aidr f t r )0-0 Inspector: Date: L( •7r�;_ r $47.00 REINSPECTION HE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No: Date: SECTION 08410 PAGE 1 ALUMINUM DOORS, FRAMES AND GLAZING SYSTEMS PART 1 GENERAL 1.01 Included Work A. Finish hardware B. Glazing C. Doors and window system frames. D. Permits: Secure and pay for all building and electrical permits. 1.02 Reference Standards Conform with requirements of the following Reference Standards, as supplemented and modified hereinafter. 1. National Association of Architectural Metal Manufacturers (NAAMM) Architectural Metal Finishes Manual. 2. The Aluminum Association Designation System for Aluminum Finishes. 3. Architectural Aluminum Manufacturers Association (AAMA). RECEIVED 4. American Society for Testing and Materials (ASTM). CITY OF TUKWILA 5. Flat Glass Marketing Association (FGMA) MAR 2 3 1999 1.03 Quality Assurance A. Fabricator / installer: Must be experienced in the fabrication and working of Architectural metalwork of the highest quality; must have plant, facilities, and personnel adequate for the satisfactory production of required components. 1.04 Submittals CITY OF TUKWILA APPROVED APR 0 1 1999 AS NOTED BUILDING DIVISICiN PERMIT CENTER B. Warranty: Aluminum door, window and frame fabrication, installation and glazing shall be warranted for 1 years. Shop Drawings: Submit for approval; show full -size detail of sections, complete NUCeD details of fabrication. Show clearances with other items of work. covtvrclog Ofd GAN Indicate the following: 1. Elevation of each door and frame type. 2. Condition at openings with various wall and counter connections and materials. 3. Location and installation requirements for hardware. 4. Connections and trim. n: \96crflspecs \08410 04/22/1996 p cyc GO'? SECTION 08410 PAGE 2 ALUMINUM DOORS, FRAMES AND GLAZING SYSTEMS B. Samples: Submit samples of metal members for aluminum doors and frame sections; full size by 24" length showing profiles and finishes. Include one set of color chips represented specified color and finishes. C. Product Data: Submit manufacturers' published literature for specified products and accessories as applicable, including manufacturers' specifications, physical characteristics and performance data. Submit as a supplement, manufacturers' instructions and directions for application if not included in manufacturers' published literature. PART 2 PRODUCTS 2.01 Materials A. Aluminum: Extruded shapes shall be 6063 -T5 or T5 alloy and temper; sizes and shapes as indicated; 1/8" minimum wall thickness. Trim, beads and stops shall be .050 minimum. Cut corners square and fasten with extruded corners brackets and stainless steel screws. Black anodic coating; AA- M12C22A34 Class II mechanical finish, non- specular as fabricated, with medium -matte etch and minimum thichness 0.4 mil. B. Fasteners: All exposed fasteners shall be stainless steel. C. Glazing: Clear 1/4" tempered or laminated safety glass meeting UBC Standard 54 -2 with manufacturer's name and glass quality permanently etched at corner. 2.02 Doors, Frames 1. Narrow Stile Entrance Aluminum Doors 1 3/4 ", by 4 1/2" or approved. Sizes as indicated. 2. Counter window system with pass thru and speak holes. Aluminum frame assembly 1 3/4 "square or approved. 2.03 Glazing system A. Safety glass(all glass) ASTM C1048, Kind FT fully tempered, Condition A uncoated, type 1 transparent flat, Class 1 clear, Quality q3 glazing select; conforming to ANZI Z97.1; 1/4 inch thick minimum. B. Glazing accessories 1. Glazing splines: Resilient silicone extruded to suit glazing retaining slots; black color. 2. Glazing clips: Manufacturer's standard type. n: \96crf\specs \08410 04/22/1996 2.04 Hardware SECTION 08410 PAGE 3 ALUMINUM DOORS, FRAMES AND GLAZING SYSTEMS A. Hardware for Aluminum Entrances shall be furnished and installed by the door manufacturer and shall include the following or approved. a. Hinges: b. Locks : c. CYLINDERS: OFFSET PIVOTS by Door Manufacturer Pushbutton Locks Ilco - Unican L1000 series w/ matching faceplates one each: court clerk counter- LRP 1020 S 26D 41 back court area- LLP 1020 S 26D 41 Schlage E series All keyed cylinders shall be subject to the existing Schlage E series. Owner will install the permanent cores. All cylinder items shall be furnished with visual key control with key code stamped on the face of the keys and marked on the back or side of the cylinders. d. Panic Devices: Adam Rite Life Safety series 8400 e. Threshold: none f. Emergency Exit Lights -120 volt fixtures provided by owner. 2.05 Fabrication A. Fabricate doors and window frames systems with extruded section stiles and rails with corners rigidly joined and welded; make provisions for other hardware to template. B. Workmanship: Free from mars and buckles; angles clean, sharp and true with all joints precision fitted. Make connections with concealed fastenings wherever possible. Fabricate all work with allowance for expansion and contraction; assemble to be permanently watertight. C. Fit and assemble component parts in the shop insofar as practicable; fit, assemble, mark, and disassemble work that cannot be permanently assembled in the shop to assure proper fitting in the field; mark assembled components to correspond with shop drawings for placement location and erection on the site. D. Form all exposed exterior joints with concealed fastenings; miter exposed perimeter corner joints and butt other exposed exterior joints. Form all exterior joints to hairline machine accuracy; seal from back permanently water and weatherproof, unless otherwise approved; match adjoining surfaces for continuity of line, profile, and finish; all surfaces flush. n: \96crf\specs \08410 04/22/1996 SECTION 08410 PAGE 4 ALUMINUM DOORS, FRAMES AND GLAZING SYSTEMS E. Provide rigid reinforcement at all corners and joints on interior of frames; make connections to inside of frames with spot welding or concealed mechanical fastening. F. Fabricate frames for accurate fit. Fabricate framing members to allow no more than plus or minus 1/16" tolerance in variation from indicated width at sealed joints with building construction. G. Fabricate components to allow for thermal expansion and contraction and to maintain watertight integrity of system; design for noiseless movement that may be caused by 120 - degree ambient temperature and its resulting surface temperature; fabricate so as to prevent buckling, opening of joints, failure of seals, undue stress on fasteners and anchorages, or other detrimental effects. H. Protection of Aluminum: Apply zinc - chromate primer to contact surfaces of aluminum in contact with wood, concrete or masonry. Provide 2 heavy coats of zinc - chromate primer to contact surfaces of aluminum in contact with dissimilar metals; 1 coat may be applied to each surface at Contractor's option; paint is in addition to shop coat on steel; where isolating or gasketing tape is indicated, or where factory applied coating is applied on aluminum, primer may be omitted. PART 3 EXECUTION 3.01 Installation A. After removal of existng glazing system at clerk counter and basic carpentry preparation , erect members where indicated with all members level, square, plumb, at proper elevations as indicated and in true alignment with other construction; rigidly attached to structural elements of the building; install hardware to template as indicated as required for satisfactory operation. B. Install glass per FMGA Manual, Chapters VIII and IX. C. Provide all necessary electrical equiptment and basic materials (wire, conduit, boxes, switches etc for a complete, safe, installation per NEC. Connect to exisitng emergency lighting circuits. 3.02 Cleaning and protection. Upon completion, clean all surfaces free from dirt, stains, or other defacing marks and materials; leave all exposed surfaces free from scratches, dents, and other defects, free from soil, and polished. END OF SECTION 08410 n: \96crt\specs \08410 04/22/1996 0 Im J ED , gcoF I A IIRII 1111111111M ir wcstsft& 1 aIIV'Mr: (man (=.c.2) rot.E .sir • .411:P e CI • •k- ANA0Alsain-IPetE 1,:lz.• Pr Cc:: sul); b errcrs and omissions and s1 I,. d :not authorize Ms violation of GC)NIIL I ) I N ± 0 r aCciel" el e7ke-44Ki COPY --- z'Affer Ibosipt of co CITY OF Pin APPROVE PIECE' CITY OF • 0 E'RMIT ifkr/ALAODLA4 rr\ Villa 7. - - --. I3 BLACK • . y. � �JCTN. 'mil;_:_• EAF ; C% • . 7 i$ENIQN JUN.CTI.ON. V J, wa�c RM. MLA aq • ,! • / // N � s U® j ° /., 1 . ` 2 (] VE cc _gr/aJAcIL CFtAMigEf E /'QI Fog. •P.I d DCiVLS man • r:LE CO:=Y 1 lInc:. not out/today the violation of any •�� or NIMolpt of contractor's a1G -�3 1'GTS "Z _S1�XLT 4 111 elect .. ILL_ qg- CITY OF TUKWILA APPROVED APR 0 1 1:909 RECEIVED CITY OF TUKWILA P %3ig9 n EF MiT CENTEF ' PERMIT CENTER 4 FA-c . or . GOUKr PT. PERMIT CEM ER 1 - SCAL6.0 v .s."0= V-0 Nr4s1 --- AC - 0 - viircevwkcci-L:RIPPED -- tv PrOvit7L akato.16 !V X 7 Doe.: Fame- "ThUtS6.0 111.4tr_ wow cf APrirrioNkt.,_wi ZIIJ u - - -- 15 41. pp, .. aQ 01.0c,kiNca CITY OF TUKWILA APPROVED APR 0 1 1999 RECEIVED CITY OF TUKWILA MAR 2 3 19 PERMIT CENTER /- ir PROVO. '3 X 7 Sr't , 0o: * reAME- w/o 1V-4- ?Yu- w +noj cf APrli noNAL- t4Hpoo --i-K Z "- ALt tMINv ' FI?Am_p . �- . 2.!' cemr! Tom ..,. _--411C -311/_"-*N i7ARIPPS" r FRoVRA, wn 4L August 6, 2001 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Mr. Tom Pulford 6300 Souticenter. Blvd Tukwila, WA 98188 Dear Mr. Pulford: RE: Permit Status D99 -0093 6200 Southcenter Boulevard In reviewing our current permit files, it appears that your permit to install security doors and windows, issued on September 3, 1999, has not received a final inspection by the City of Tukwila Building Division as of the date of this letter. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and • void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if the final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit rile No. D99-0093 Dunne Griffin, Building Official 6300 Southcenter Boulevard, Suite 1/100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 April 14, 2000 Tom Pulford 6300 Southcenter Blvd Tukwila Wa 98188 . Permit Status D99 -0093 6200 Southcenter Blvd Dear Mr Pulford: Department of Community Development Steve Lancaster, Director In reviewing our current permit files, it appears that your permit to install security doors & window, issued on September 3 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, G at.tr- Bill Rambo Permit Technician Xc: Permit File No. D99 -0092 Duane Griffin, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206.431.3665 \PR-ROUTE,DOC 6/98 C'eteier;•+ l ; Coo /L '_ ` 109 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D99 -0093 PROJECT NAME: gx Original. Plan Submittal Response to Correction Letter.* CITY°;OF`:TUKWILA— COURT, CLERK SECURITY WINDOWS. DATE: 3-23-99 Response to Incomplete: Letter Revision # After Permit Is Issued DEPARTMENTS: B Idifig Division Fire Prevention l 410 c �'9 +L 3 - Pu Ii W rks Structural ❑ DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 3 -25 -99 Complete J1 Incomplete ❑ Comments: TUES /THURS ROUTING: Please Route Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) Planning Division X Permit Coordinator Not Applicable ❑ No further Review Required REVIEWERS INITIALS: DATE: APPROVALS OR CQRRECTIONS: (ten days) DUE DATE: 4 -22 -99 Approved 111 Approved with Conditions Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: City of Tukwila Fire Department Fire Department Review Control #D99 -0093 (511) March 30, 1999 Re: City of Tukwila Court Clerk Security Windows - 6200 Southcenter Blvd. Dear Sir: Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1003.3.1.5) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439