Loading...
HomeMy WebLinkAboutPermit D99-0153 - Southcenter Mall - Rainforest Cafe - Storage RacksRainforest Cafe City of Tukwila t (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9004 Address: 290 SOUTHCENTER MALL Suite No: Location: Category: ARET Type: DEVPERM Zoning: Const Type: RACKS Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Contractor License No: PCLCOSI099NW Permit No: Status: Issued: Expires: D99 -0153 ISSUED 05/20/1999 11/16/1999 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERS /AFA East: .0 West: .0 Streams: OCCUPANT RAINFOREST CAFE Phone: 290 SOUTHCENTER MALL, TUKWILA WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT TODD HESSON Phone: 602 -265 -7769 2828 N CENTRAL AV, SUITE 110, PHOENIX AZ 85004 CONTRACTOR P C L CONSTRUCTION SRVC INC Phone: 425 -454 -8020 PO BOX 52868, BELLEVUE WA 98015 *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *1 Permit Description: INSTALL RACK STORAGE. *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *1 Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *, TOTAL DEVELOPMENT PERMIT FEES: $ 141.86 *************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *, Permit Center Authorized Signature: e2/ -- -Date: 6-20--Q1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development per Signature:___ Print Name:_ Date: /q%44 20%;pi This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ddre:ss 290 SOUTHCENTER MALL Permit' No:', 899.0153 Suite , { _. Tenant Status 'ISSUED Type • ;DEVPERM 1 ": Applied:! 05/04/ 1999 arcel; #::.:262304-9004 Issued :I 05/20/1999 ************************************* * * * * * * * * ** * * * * * * * * * * * * * * * * * ** ermit :Conditio.ns t .t 1 No changes will changes wi 1 Yibe made to the plans unless approved by the Engineer, and the Tukwila,,.Bu.i.1.din,g Division :All permits, inspeotiot�: >records, an d; approved plans "shall ..tom. � X .., ..,. available `at t e •job Msite prior'°tot.he :As.tart of any con- struction. 1T,h.ese° documents are :to be ma�lntained' and avai l u. k rd . ,r u� P r: h '�,. �� a . able untj;l final inspection`a.p.•p,rova1I1A granted All construction to,. :be 'done;in 53.conformance Wi.;th approved tans, and 're u,l.rements• of the Uniform rBuildin Code (1997 Editrion). as amended, Uniform Mechanica"1 ,Cb 1e :.(,19 7;Edition), an:0 Washin "gton State Energy,.Code: (1997a� :Ed i i Va :.l di.ty 'o,f Permit:: The i ssuan ' ce of a 'permi:t•. orm approval of. pfl,ans,. specifi'7cati and comp.,utatione ahal st ued Ito beta permitt; for, or °an approval of,. any''vio;la,tion' � sar r } f = o r any ;of the prov i s t onsp). of `the bu i1:d i ng. code or ohf,ki ar} o.ther orFd i riatpce of the �,�ar t sdtt ct ikon,;' No pet�m i t pr'esum.i ng ( givers' ?uihor•�t,tyU to violate or . / ?cance4l the prov9siens of ,,thys code shall• be.;va1 id: � :. I:. L1.L. ri• CITY OF TWWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Project Number: Permit Number: '11-0193 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ProjechName/Tenant: 1�r)►n)lDges� (/ FE - sip 7PIco✓7c/e/' Moil Value of Construction: 000. 00 Site Address: City State /Zip: 2.c7 0 S63uciGt eepie /22,011 g 7,1c .7"hkc,DJI 1,04 Tax Parcel Number: 2/0.2,304 - `)'DO Property Owner: the Ric lined F 3. Acr .) ti3 )-0eA.p, bur Phone: G2/6) $7/ - -#860 Street Address: City State /Zip: ..25 - .A1,25- re ✓19tete iq (ci<y, R% e /eve /A dd A// «iyq- Fax #: (/6) 87,2-a23o8 Con ctor: 0- (0lose/i'u,.y(0 u seiv /ces, /,uc Phone: C642) a88-7,6o Street Address: 559s/ City State /Zip: 953c :3,47 ✓neC 190 (9 g0 &A. 6 /,»m,.. Y.rin n1, Fax #: ((o/ a) 8'??S" /6-e r7 Architect: ' 0' eLtn,.rt)chAm MI/Y7 ;IIDIU 0c,�; `le ►eI R, Phone: (/'2) "2'5 -77(2' Street Address: City State /Zip: gSo ?g 71.1 .C'o4iav/ /4ue. STS' ) fie) A,00 n)Xi 19 z Fax #: (C2) 265- 7763 Engineer: g'S�oo.2t Relgc�s�dpd i ,Osse,c...v is Phone: (12) 29%2— / /oZ 3 Street Ad8'ress: City State /Zip: Fax #: /902 4,1,,,-i 9 cii 11 R syn 20c.. v 2z A&I p7,u c,c:&)? (6/2) 2 2 - Y0/5-- Contact Person: , ' ‘ Phone: "7-0D ° H e 5 $ QAJ Crew n, vngLiAAl *elf17iWoi[ ale /lel 14002) 165-- 7X? Street Address: City State /Zip: Fa #: 2Rifl8' M (o In ^ /r-.4 / 14o EVe 1 / /6.), PAoe.A.ly Az /X/9;1) 2(05- -776. 3 Description of work to be done: p J`'L� ` ocescc e 94 ,(_ 1�e i9i Existing use: Pi Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: rig Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes ❑ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ,® yes ❑ no Existing fire protection features: I sprinklers CRI automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: e ,jdOexisting Area of Construction: (sq. ft.) 5 one Will there be storage of flammable /combustible hazardous material in the building? ❑ yes RI no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safely Data Sheets APPLICANT REQUEST. FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW. OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, The building official may extend the tirne for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale application accepted: Date application expires: Applic lop taken by: (initials) � 1 PLEASE SIGN BACK OF APPLICATION FORM CTPLRMIT.DOC 1/29/97 ALL COMMERCIAUMULTI -FAM . TENANT IMPROVEMENT /ALTS ION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER A ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN A BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) • 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit,this permit applicatiort;and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AUT Q ,ZED AGENT: Signature: 11 17 Date: Ir1/1Fa y 1/ !�G / // Print name: in nnnn I^ �1v- 6 Phone : 2C6 ` 6 -6726 Pax II: :06 igk- l�7.25- Address 7 1 qV ,,`(tit ? YL ,/,, ,, n, / ,,l/ City /State /Zip rak u., r %1'l 1c_%;4 CTPERMIT.DOC 7/29/97 ar. ;`�`r%'ir':.•"YiS`F�: •'.R . :1; , +F,r fir: . ..• a. • �. ,�. i: a' * *,* *, * * Ik * * 7k * 1�f',, ***,*;`*:#,******; 7C y:.:f :f lk I�f: �' �t 1: 7k *.1: v:�11�;1�:f �7�f:7k 1�a 7C ****Ii.. • KWILa, WA ` r . TRANSMIT::' • * * * ** * *' * * * * * * ** * * * * *,1 * ** * ****44******* * * * * *. *:. TRANSMIT Number R980007;0 Amount. . 87..75 05/2.0/99 14 53?•. ayment Method: CHE`CKi `Notation.: DOUGLAS .ORGAN snit TLS L 2. ermi;t :No D99 -0153 Type DEVPERM'DEVELOPMENT PERMITT:` Parcel No S s 2623 0S4- 9004:.' to Addres 290' OUTHCEN TER MALL i Total .Fees: 141.:86 This Payment {87 75 Total .ALL :Pmts 141.86 'Hal'ance '00 *' *. *' * *. *. *: * * * * *. *. ** a****;*********:*.***.**** * * * * *. * * * * * * * * * * * * * * " *` * * *. * * *. • • Account Code " Description Amount 060 /322..10.0 BUILDING - NONRES 83.25 000/3.86 904 STATE BUILDING SURCHARGE 4`. 50 '3558 45/24 9710 TOTAL 152.4 • •,, .'• • • ••• .••• .••• 35500/24 9710 TOTAL 152.01: ** *k *:lk *A*k **#r.t /. * *yt 4 **4 **k * *A*hkk:* *A t * *A *tt4k *kkk4t*.*•A* * *A•*t* M.TY 'OE: TU "tO. Li. A WA 1J4'q-' I. TRAN ►lIT *' ** 3: * * *'hk* l * *0 .i0; ik+.4r.gr•kk'h *:t *tit :h *11•.k*A•1 4.11 —f :4A*Akh*'1.k* ** **4.*•a.lt*lsk•k: 4* RANSSMIT Number.,: P98000 r9 `Amount: 54. i i. 05/04/99.1006 Pavne:nl..14ethod: 'CHE:Ctf. Nottion: DOUGLA5 .ORSAN. Ini.t: 13LH Pai?in1t t.lct: ;_D99-0153: ' Twpe:: O> VPFUt4 DEVELAPMEt 1 PEUMI7• Psirc a 1 :;Nb :.:262304- 9004 13 1 te: Ad33ress z :•296 :GOUTHCENTER MALL 'Total Fees. 141.136 `4 11 Total ALL Pmts,: 54.13. Rail an6e: 137.75 stir * *k *d* 4. * *4 .irit4. *+;ic'Rle.A. *:t Or It. * l• sl * *' *slrtof4— A * *A * *st;4lt' *4r st. * * 'dF * * *. *•k.. �1��nunt . Code Uescr.i p.t.i on -.000/.345.830', PI.E'iW.CUECV -• .NONRES Amount 54.11 1120 05/079717 TOTAL 54..1 INSPECTION RL..JRD Retain a copy with permit INSPECTION NO.. CITY.. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 1 PERMIT NO. P 'ec ::. RLt �v es—r- T oop<p/t-ti) Add ss: Special instructions: Date wanted: _ . G.P / , a.m. P.m. Reqr: Phone: ►i, . pproved per applicable codes. Corrections required prior to approval. COMME Inspector• 4"/ El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: INSPECTION NO. INSPECTION _RED Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-367D Project: ' (reSt- Type of Insp on Address: 0 stai jot 4 Date called: 4 Special instructions: Date wanted: (/ Z 9c1 MO p.m: Requester . Phone: Q� p� / _ I0 01z. W proved per applicable codes. Corrections required prior to approval. ,. COMMENTS:. Date $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: i-t •`1:N•4•4" • y • City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Permit N •U - l i \ j .1k- LOX Address ac=\ t- R.rktC" M LL Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signa ure Date FINALAPP.FRM Rev. 2/19/98 , T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 57S 4439 FOX ENGINEERING 8060 Telegraph Road Downey, CA 90240 (562) 806.1337 (562) 927.2500 Fax (562) 927.2509 Joe ZA SHEET NO OF CALCULATED BY CHECKED BY DATE SCALE DATE { I I i t + Z I i I 1 t i STORAGE EQUIPMENT INC: j ! 1 1 ; ~ , ^ I i 1 1 I 1 I ! SEISMIC! DESIGN FOR FLOOK ANCt O '6E . OF PROPOSED • I j__.1.__ STORAGE SHELVING AT BISHOP FIkTURE I . 1 I 4 . ._._ ._...__. , I i i + r, : M\ i I 1 I i R EIS PONS I!B I L I;TIY ; • -FOX; ENGINEERING !WAS ENGAGED - -• -.. TO ----PROVIDE-1---CALCULATIONS ---1--AND .-1---t-td--- CONSULTATION IN !CONNECTION WITH THE ABOVE DESCRIBED PROJECT.1 WE1 ; HAVE IlO AUTHORITY INSOFAR AS CONTRACTOR'SIOR OWNER'S PERSONNEL, ARE! --------- —CONCERNED . -•� -• «- OWNER •;- AND.... CONTRACTOR .- •- ARE..1-ADMONISHED -TO - .;OBSERVE; --ALL SAFETY ORDINANCES FOR PROTECTION OR 'PERSONNEL .! t i l t i 1 I ; I ; I 1 ' I i i I IN MAKING - USE-OF- ••••THESE•- DOCUMENTS, -; CONTRACTOR/ OWNER ••AGREES...•TO HOLD ••• FOX I ENGINEERING! HARMLESS FROM ALL COSTS OF LITIGATION ? THAT ; MAY ARISE OUT OF ALLEGED 'DAMAGES ;OR INJURIES ASSOCIATED WITH THE WORK •DEFINED •BY ••• ..- THESE ----DOCUMENTS - DOCUMENTS INCLUDING • •• ATTORNEY-'• S....- .•FEES - .!....AND • -t JUDGEMENTS, UNLESS; IT IS PROVEN; THAT; SAID INJURIES OR DAMAGES RESULTED i FROM ERRORS'INOR OMISSIONS FROM THE DOCUMENTS.' i t 1 i t j • RECEIVED ; -CITY OF TUKWIL'A` • • • MAY 0 411999 I PERMIT CSNTER, � f E.. t I t MOW tad 001 sn«ai rat thew) FOX ENGINEL_.iNG 8060 Telegraph Road Downey, CA 90240 (562) 806.1337 Fax (562) 927 -2509 JOB 91- SHEET NO. CALCULATED BY CHECKED BY DATE SCALE �. fbX OF 2 DATE 4 - 1 / - , 1 1.•. ^.. yfs� Vsrrc -lc.o �tY ii•A=Kf l c, licaa.-t , lac ' -p. yN 1 ! o (,1�: -+ 9.1-71. 1. 1, cr1- 9Dom. . +.4.K:4..2.7)- .loo(Cox.7y).. ?x l:ry! e• i /klfi - 4 Li ...... ram ..........:...........',.... 1-+).< a. ( ...................:........... (.7c?) (.z-"7. ) - =osV x r Ic) !......`.........>5.1 1 ......i.,.11 .. .1 .:� 4�1c,F 1' D1 ..... .tom...... � l�i%....J►.11'Tr -�.. '(p. -f� i ii ... V, • •..............:........... : f V /c4 . -7.. V1-,1. (12a.)(21.Cpa) -loo(' 2:k 1.51 1 ov + • 2-y� ; = 0 I o S`75' oft ", . V /.) ''1 . .T • ?....1. --1- 0.2`x) .o PROOUCT 201•I (OW Shwa) 201 IPadd.di .f Ztf. S:ni; 3.%) li f;.J. 1•(!Y°' hKwr av�,Z!CS';S' •a:,•,',aW '.)„en.... < +c�?„f, aaet /A. a2::°.:?' �',; ieid'^ siii `�•.r <,ti.bti.`aii:'{�ii�L..li �eilny..., trr, 7i.: PL: s�rtu'.: 4. Yv.' r% �hx.. ,,.,..`,'.%.�.�.V.+'.•i3�..00l ?edrrn\4 CooYd. r,„, AZ, PLAN REVIEW/ROUTINd SLIP 5,t.a .h. ia't• IlY`NUMBER:. D99 -0:153 'ROJECT; NAME:,.. RAINFOREST CAFE .: XX Original PIan;Submittal • Response to Incomplete:; Letter. • ' Response to'Correction Letter .:# Revision #' After Permit.Is Issued• DEPARTMENTS: Bui ding Division Public Work Fire Prevention DK 420° 3-12q�n Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 5 -6 -99 Complete kt Incomplete n Not Applicable Comments: TUES /THURS ROUTING: Please Route L No further Review Required n Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions DUE DATE: 6 -3 -99 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: \PR•ROUTE.DOC 6/98 City of Tukwila John W. Rants, Mayor Fire Department Fire Department Review Control #D99 -0153 (510) Thomas P. Keefe, Fire Chief May 11, 1999 Re: Rainforest Cafe - 290 Southcenter Mall Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number John W. Rants, Mayor Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 2. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) When two or more exits from a story are required and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 John W. Rants, Mayor Thomas P. Keefe, Fire Chief when two or more exits froma room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) Manually operated edge- or surface - mounted flush bolts and surface bolts are prohibited. When exit doors are used in pairs and approved automatic flush bolts are used, the door leaf having the automatic flush bolts shall have no door knob or surface - mounted hardware. The unlatching of any leaf shall not require more than one operation. (UFC 1207.3) All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) 4. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7S•4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Page number 4 Thomas P. Keefe, Fire Chief ' (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 6. Storage may not be closer than 36 inches in all directions to ceiling -hung "Space or Unit" heaters. (UFC 1109.2) 7. Storage may not be closer than 18 inches below sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) 8. To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) 9. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) 10. Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) 11. Racks designed for high -piled storage must comply with section 2207 of The Uniform Building Code. Please contact The Tukwila Building Department for details pertaining to design and installation standards. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 1908 ohn W. Rants, Mayor 77zomas P. h'eefe, Fire Chief Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. . - ,Yours • " 5 /0 The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station.. 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 E". '••• • ' • • • . •.t REGISTERED AS PROVIDED BY LAtIAVASIF:A;d.:, CONST CONT GENERAL REGIST . # EXP DATE CCO1 PCLCOSI099Mff 06/01/1999 EFFECTIVE DATE 08/16/1991 i Signatu Issued by DEPARTMENT OF LABOR AND INDUSTRIES PC L CONSTRUCTION SRVC INC PO BOX 52868 BELLEVUE WA 98015-2868 .; .; , ; ..„ ; -; • •• • • " ;;• ; • 7, ' ' • • ! •:} ••.1. ;: : . . .• .7 : FULL PERIMETER O.D.R.'S SCALE: 3 FULL PERIMETER O.D.R.'9 SCALE: ANGLE POST ANGLE POSTS / • STARTER t Y INTERMEDIATE SHELVES INTERMEDITE 0 SNEL B © pp 8 F.02 / 1 1 SCALE: 3 TO SUPPORT HANGRD LOCATION T.B.D. HANGMOD UN TEE POS • CONTINUI OF 0011A A? ?ROVE 4A3/ 9 1999 I Underatend that the Plan Check approvalsare sublact 10 errata and omissions and approval of plans Boas not authorize the vialatron of any anoplatl soda or ordinance. Receipt r c o L 6 . , vector . 5 oopv of apps p• n roo, — Iw o a5• �,VIL 3 q �o�cnuFO� ' RECEIVED CITYOFTOKWIk.Aiwi MAY PS9MITCENTP TYP. U.N.O. 1 17 :. A 4'_0" M FH 1' k •.•J - VP 01 SCALE 1' - LOC. OF HANGROD UNITS NOTE: ANCHOR ALL NALL UNITS TO THE NALL. / FULL PERIMETER O.D.R.'S SCALE: 3 FULL PERIMETER O.D.R.'9 SCALE: ANGLE POST ANGLE POSTS / • STARTER t Y INTERMEDIATE SHELVES INTERMEDITE 0 SNEL B © pp 8 F.02 / 1 1 SCALE: 3 TO SUPPORT HANGRD LOCATION T.B.D. HANGMOD UN TEE POS • CONTINUI OF 0011A A? ?ROVE 4A3/ 9 1999 I Underatend that the Plan Check approvalsare sublact 10 errata and omissions and approval of plans Boas not authorize the vialatron of any anoplatl soda or ordinance. Receipt r c o L 6 . , vector . 5 oopv of apps p• n roo, — Iw o a5• �,VIL 3 q �o�cnuFO� ' RECEIVED CITYOFTOKWIk.Aiwi MAY PS9MITCENTP TYP. U.N.O. 1 17 :. A 4'_0" M FH 1' k •.•J - VP 01 SCALE 1' - LOC. OF HANGROD UNITS NOTE: ANCHOR ALL NALL UNITS TO THE NALL. NO 14 GAUGE NOTE' 14 GAUGE SCALE, N.T.S. 5/16' 0 RIVETS (TOP.) TEE POST IYP. 0 ALL CONTINUING UNITS NOTE' 14 GAUGE NOTE' SCAR 14 GAUGE TTF. 0 PLL STARTER/ENO UNITS NSEF: USE WHERE FOOTPLATES' ARE REQUIRED ` (2) -1/2 DLA M1111 BOLTS I (2 1/4" ERB.) © io • !•I • 0 All CONTINUING UNITS 1 /2" O.C. TEE POST WELDED TO FOOTPLATE. (FULL FACE PERIMETER WELD) 3 -1/4" x 4" x 3/16" FOOTPLATE W/ 9/16' M0. ANCHOR HOLE USE WHERE FOOTPLATES ARE REWIRED (1) -1/2" DU. MK BOLT (2 1/4' EMB.) TEE POST WELDED TO FOOTPLATE. (FULL FACE PERIMETER WELD) 2 -1/2" X 3 -1/4' X 3/16" FOOTPLATE W/ 9/16" D10. ANCHOR HOLE ANGLE POST W/ FOOT PLATE SCALE: N.T.S. TS 0 All STARTER /END UN NOTE" 14 GAUGE OP. TEE-POST BGWa -NOG( RISC TE/ ABLE 9PPCRT BEAN TX BOUM TO TEE -POP a01BIE WET BUDS ITu PEIOE,TR © II DI" -i!- ...... .9 !. SCALE NOTE" I4 GAUGE ANGLE -POST 0 EACH AISLE EN0/ CORNER (STARTER) 91EVANG UNNS Ark SCALE: N.T.S pqq -oi53 Ta-a¢R RITE M/ SUPPORT CHANNEL BTAUI BOLTED TO CORNER ON POST DOUBLE POET BEANS PAL PERMEIER USED AS NCIPLAIE 0 DECK LEVEL CUE SHELF SYSTEM SCHEDULE 1O -O" 6 3 3 TOTAL UPRIGHT HEIGHT TOTAL SHELVES PER UNIT TOTAL END Q.D.R.'S PER UNIT TOTAL FRONT Q.D.R.'S PER UNIT NOTE: SEE PLAN FOR SHELF AND AISLE SIZES. GENERAL NOTES:I 1. � O JJJO N BC{ (,1@� O VE U 11R . 2. 14 . , ASD AWN. SEEig4i Plc.; LELE t9Ef - SPECIFICATIONS. BARS E IS FASTENS N W/ SADDLE CLIPS 3. ALL SHELVING/ CUE COMPONENTS 14 GA. STEEL 4. ALL SHELF SIZES ARE SHOWN WITH 1/2 "x3/4" GROWTH 5. ALL COLUMN DIMENSIONS ARE ON CENTER, UNLESS NOTED OTHERWISE 6. U.N.O. DENOTES "UNLESS NOTED OTHERWISE" 7. O.C. DENOTES "ON CENTER" 8. IN -IN DENOTES "INSIDE TO INSIDE" 9. 0. -0.. DENOTES "OUTSIDE TO OUTSIDE" 10. O.H. DENOTES "OVERHEAD" 11. T.B.D. DENOTES "TO BE DETERMINED" 12 A.F.F. DENOTES "ABOVE FINISHED FLOOR" 13. B.O. DENOTES "BY OTHERS" 14. N.T.S. DENOTES "NOT TO SCALE" 15. EQ. DENOTES "EQUAL" CT1Y pTUDILA 16 Ck DENOTES "CENTER LINE" MAY 0 4.1999'. 17 4 P` DENOTES "NOT APPLICABLE" PERMITCENTEW 18. ALL CALLED OUT SIZES ARE GIVEN: #1 WIDE #2 HIGH! 93 DEEP FROM THAT "VIEWPOINT : :a: NOTE: I 1. SEE ,P FOR E�DS AND Talk 2. D L AND S N I. IGNS ULT M HOP DRA I` .FOR AC 11 3. STEEL SHAPES YIELD Fy =40 KSI U.N.O.' 5/16 "0 RIVET ASTM C1008, Fy =40 691. 4. STRUCTURAL STEEL RECTANGULAR OR SQUARE TUBES SHALL CONFORM TO ASTM 0500, GRADE G (FY = 46 KSI) CONFIRM ALL QUANTITIES WI PROJECT MGR Ii