HomeMy WebLinkAboutPermit D99-0172 - Boeing Employees Credit Union (BECU) - Office and Closet.t4Ncrito-,,:otoatzW!,.8tomOthtall ,,vgaoilka*etact0::tmmttftVotemitiI*wri D99-0172 12770 Gateway Dr. Boeing Employees Credit Union City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: Address: Suite No: Location Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: 271600 -0075 12770 GATEWAY DR AOFF DEVPERM C /LI 2 -FR 001 North: TUKWILA Fire South: .0. East: Sewer: SEPTIC' Slopes: 'Y Contractor License..,No SELLEC *372N0 OCCUPANT OWNER CONTACT .. CONTRACTOR' BOEING EMPLOYEES CREDIT UNION 12:770 GATEWAY DR, TUKWILA, WA 98188 BOEING' EMPLOYEES'CREDIT UN RO'BOX 97050,'SEATTLE WA 981249750 CLAIRE MADS.EN 12770 GATEWAY DR,• TUKWILA,.WA 98168 SELL.EN CONSTRUCTION CO. .INC. P ::'0`..: BOX" 9970, :SEATTLE; WA 98109 Permit No: Status: Issued: Expires: Occupancy: UBC: Protection: .0 West: Streams: D99 -0172 ISSUED 06/01/1999 11/28/1999 OFFICE 1997' . SPRINKLERED /AFA .0 Phone: Phone: (206)439-5961 phone: 206-812-5131 Phone 206 682 -7770 **•k * **** * * *;*�k`k•k * * ** * * * * *** *** * * *•k'k * ** k * * *•k * * * ***•k•k kv. *•k *•k *•k *•k *•k k *'k * * * *.* k *•k ** k** * *•k k*1 Permit Description: DEMOLISH CLOSET; ENCLOSE ONE OFFICE AND ONE CLOSET. * * * * * *•k * * **:k ** *1( *•k * * ** * * * * * *•k * * * *•k * * * ** sk* k***** * * * * * * ** ** * ** * * * * * * *•k *k** * ***g Construction Valuation: $ 17,000.00" PUBLIC WORKS PERMITS *Water Meter Permits Listed Separate) Eng. Appr Curb Cut /Access /Sidewalk /CSS. N Fire Loop Hydrant: N No Size(in) .00 Flood Control Zone: N ;Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Movi`ng ,.Oversized Load: N Sanitary Side Sewer: N Sewer' Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N *** ** k* k * * * * * ** * *•k * ** k• k************ * * *•k * * * * *. * * **'k * *-k*. * *'k *k ** k *•k *'k** *** k•k * * * *•k* * *'*** 1 TOTAL DEVELOPMENT PERMIT FEES: $ 465.26. *********************• k' k********* **" k**********•**** k*:***** k * *k * * *'k•A *k *'k•kk * * * *k** * * *kkl Start Time:.:. No: Private: N End Time: Fill: End Time: Public: Permit Center Authorized Signature: �UVrrv►'' Q __ Date: .LJ ( --6R I hereby certify that I have read and examined this permit and know the to be true and correct. All provisions of law and ordinances governing work will be complied with, whether specified herein or not. sane this The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development ermit. Signature: Date : ////1 9 Print Name: 4:4[4 / 445 jet. ktAps6e This permit shall become null and void if the work 180 days from the date of issuance, or if the work for a period of 180 days from the last inspection. i s not coninienced within is suspended or abandoned CITY OF TLIKWILA Ad'dr ens 12770 GATEWAY; O P rmy G '.No 1799 0172 te Terjant ta.tus ISSUED. Type: ,DEVPERM : Applied 05/18/1999•` cel':. #:. 271 00 0075 Issued ,OG/0i/1999 1'k *k ** *k *. * * *k * **k*** k* *•k * **'*.*k **; *.•4'k•k *k,* r *kb*b *k*. *k•k **** *b bb *•k *k•k**•bk4'k`kkb*: Permit. rondytianc >1 ` No changes wi1.1 be.. made: to. :the 'Plan s :unless' approved' ;bv the Engineer and the TuFwil,a Bu i.1d.irxg 17 v sign L A.1 l p:er mi is inspect 1 on r t i and ap ro ed plans .sha 1 1 ;be available ;at the lob " °swi;t a fir ior, to "the : `�i ;a , any con truction • These docurnentts are: Goo be maint'a.i.,r� "edw,;and avail a�bie until: tinat i;rispect10 approval is <gfante �,'`E a Electrical er iiit,: -.`h ,` g a4tis p ,., a 1;L1 b;�: �bt-a� #-neii §jtl�r6�►�h ��the :.l(aslt ngtan State G,ivl±�n of�, Lh'ol� anc1 Indus 1.„7,1 6S amid a1 14�e1ec�t•rticai wpr k wi 1 lx' ire i nG ye.tha+� :.a ency x(248 603(1! 11 ineciArtn6•a "worn; ,hall bit \untder .separ'ete permit ,hssued by e C1.0'061' Tti4 wi 1'a ;, f , ++ : t11 cgIstW.10ti6n td be done }in contor man66 with a rr�oved , 7 pp � r'1an. and r�eyu :ir�,einent:,�,,cif,�`4 °iie' lin�fti'r�m:Buiidi"ng�Gode (1997�h`k� 'Eiii' 0; n) as�,uaniended, Gllhi;tormz Nectar i ca l : Code. t 19 7 E�1s t i ori. , \� ands}" ashprngton5y3tate `Energy ode (:997- Edition) r r� � 1 � Valei,' ti t�i;ot, Rei�rni t pe i . The issuance of a "r nr t or app , o s : r�ora�lifds.; L p`l ans sp 'i: ifs G,a t 1 ons ; 'and computations °`''sh;a 11 nit hie, stdued :to be '`a permit far , t, or 1an;jakppfrclra•l "of, any violation of „,91: sh 61, thy bus 1 }0 }i4;g,..;372$ de or of ,ariy,„t �F oche �: ord nar ce ?at./the�.jur i dir.ttlon.1 NN.o permit pr eiumir�+ yr.to F give author iGu: to violate?or° °cancel ' °th,e r,ovision: of thls <� � nose' ha14,4;bek valid � . :' t �� ! . : }�"k! � l-� x� '� � `'t�'i {z!.•.; ' 5 ' i's.F I i .rY 1 , �. � rt i . • 1. i b1 LS '' +.t .-. t, .. F Fr':�, .,....... 5• .. ,,. Y9.... ..tl'�• '., !.t;d .� � . .CITY OF TUI'WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project Name/Tenant: 0 o a Wei e. t�(PI�r g F ' G 12a D) T. U !0101! Valhi of Construction: 's1 [ 4i Doc) '' Site Address:I City State /Zip: i r-O 4A-TM VA.-r I7P I TO4.44t1G,AW.4 Tax Parcel Number: 1-1I GOO .- tso4S -1 Pr erty Owner: jo v of 6 gm, PI-4,1( c- ,' G P IT UN' Jo/• Phone: .103 - $ f 2- -51-3) Street Address: City State /Zip: 1 z -1- 4AT� wa-r' _La.l tie, i 1) vl tea Fa #: #0 6 " 43 - 61-84 SSUU Con actor: (90s-r Building Square Feet: I existing Phone: _cca- 9 Z1 - fi'4 4 Street Address: 'L2 6 47i' A 065 ivr g 616, L City State /Zip: wa ' /Dcr Fax #: zo G _ 6 2 5 - ra z,v 4, Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: Dr /Qav► ka,l,._ /e_ (c .) ;-1'7-7 0 City State /Zip: Fax #: _Contact Person: GI-.Atie_4, L ADSt;t J r(2.0) . k4.4e. le-Li Phone: 619 -- e / z- - S 15J Street Address: 12'4.10 4 4T gWAY Oa- . T U K - k l i i & City State /Zip: t k r A r I to d Fax #: ,1-6 to - 4139 '.M/ 58 /e Description of work to be done: Gi�Ss ` t o N O ,cis 4 ot■+E._, G.A.-5tm r bit,o Al. -6�t, /- 1 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 1 Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel PrOffice ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) no Will there be rack storage? ❑ yes no Existing fire protection features: a sprinklers '1 automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: I existing Area of Construction: (sq. ft.) 2602 5 4. pr: Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST, FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW ;OP:THEFOLLOW!NG: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Data gativgpted:gq Date appllcaticc Applicj�tlQnS by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM CTPLRMIT.DOC 1/29/97 ALL COMMERCIAL/MULTI -FA r LY TENAINT IMPROVEMENT/AL •ATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ 71 Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in.the,amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include ❑ ❑ Site Plari (including existing fire hydrant location(s) 1. North,arrow and scale 2.' Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4.' Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by,size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ 0 Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ 0 Indicate proposed construction of tenant space or addition and walls being demolished ❑ 0 Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. V 'ij4 Aviv 549wx+g.ce72-60. 1q Di2 T(.Ltv4 `t- TAtvv- auk P & ❑ ❑ Washington State Non-Residential � esidential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ( %D d) I /��4. Date: d" /dg) /9 Print name: #4, f Ai /lla5 p p tae :rf /Z — 2/ 3 / t. hr31i - / e Address %1 FqU Glarawsa7, Ia12 i rV,,44.4 C.,:t u/A- City/State/Zip fyz, . CTPIRMI'T.DOC 1 /29/97 a ,c}.n•t >•••w mot • •r ***A**** ***************44* •a *Ak* An*** *•k4* **k:4k*A *'.t *A *A*,4**4** 'CITY' OF 11l.K14,1141 WA — TRANSMIT. 44,h * * *t,'**A * *A*fi * * A *k TAfi % 1k * k kk A* *l, *t.*4dk t ** .1*,k k TfkANSMIT Numter. R.9800067 nn runt ♦ 465.'26 05/18/99 .1:5:00 Pay.rent ;,tlethiod: CHECK:. Notation:.RUCXUG CREDIT .Li Init: CAS Permit: tao: 4D99:-0172 Tvpe':. t »VPERri• .DEVELOPMENT PERMIT Parcel' `,Noe 71b0040't Site ..Add► °`es5,e 127. 0 GATEWAY DR Total 465'026 Tc,ta,l ALL Pmts a :465.'26 Da.lance» .00 Account Code 000/822.100 000/845.830 000 /386.904 pe c.r1 Lion . IWILt3IN8 - NGNRES, PLAN CHECK: NONRES, CSTA.T'E HOUDING SURCHARGE Amount 279.25 18 +p 1.51. 3542 05/24 4710 TOTAL 465.26 !s INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Project; -, ��� 4, Type of In Address: / 2.77n &. rt Date called: „Special instructions: / Date wanted: �- a.m. S "VC"' ) p.m. Requester: . %4 � %-IP Phone x/2--573 Approved per applicable codes. EjCorrections required prior to approval. COMMENTS: k $47. I� REINSPECTION :REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 roec: (JCS'yykyTdpofInsp ( 644a Al 4, Cj�� 49, Date called: tr0 ! / y Special i/ istr c i (�7i�� UU e Date wanted: OM . . = *� .m. Requester: / ' i Phone%Iif 730....868z/ Approved per applicable codes. ix Corrections required prior to approval. COMMENTS: 1C7 a � a Date: q7 Ei $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 ect• • • \n U tu (4L T p f I specti n: Uck 0(19 f dress: Date called: Ai._,,, '9 4,Z__ Special 'instructions: �.CL��Q ��'f1� .tVI\e,co0emeA 1 �Z "7 . ; /'; 1 ` Date wanted: 7 a.m.. p.m. Requester: CM Phone: // �W f+ `t moved Approved per applicable codes. Corrections required prior to approval. t; COMMENTS/ 2 1:404._ /_ (4L 4Q • v�- _ /=>i )-?,a e ei,),-. 4u // Ai._,,, '9 4,Z__ G!_ ryM %( ) '7 6d�. c- 4),4 1-2-_, . 5 �w 4-41 -L.. 7;64z 7 'l) Ce 6-.•i/ moved 1.I.*I 1,9 Inspector: Aid .�� El $47.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: Receipt No: Date: ,4PAgFK''' INSPECTION RECORD Retain a copy with permit, INSPECTION NO.' , •‘, ' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter plvd;i100, Tukwila, WA 98188 PERMIT NO. • 0y," • (206)431-3670 . _ , „- 4V/PrOe-fik-( 07 Project: Type of I rgto Address: Date called: Special instructions: 1DX.. Date wanted: Re.' 4ilr P roved per applicable codes. 0 Corrections required prior to approval.: lnsp Day $47. REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA INSPECTION RECORD Retain a copy with permit PERMIT NO. )431.3 Proj� %Y% / 1-,y, n' J / f v r ess nor # ate c Iled: ^7% /per, Special instructi�/�s . /S � �r`" .�. f? �_ f. CC g Date wanted: / cwhy a� m.� ii p.m. Requester: Phor3eyo ` .7563 56 8V 'Approved per applicable codes. orrections required prior to approval. COMMENTS: 941/0/°9- 5 Qom''` 7' G✓r T")-/ C& -,(-(( - C 0)4-r/ A pe- 640 c4 cc-oee Sipe_ Insp • $47.10 REINSPECTION RE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.,. Suite 100. CaII to schedule reinspection. Receipt No: Date: City of Tukwila: Fire Department :TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM .Project Name E `\) John W. Rants, Mayor Thomas P. Keefe, Fire Chief Address \ 2-1 b C3.JC.0 y a_ Retain current inspection schedule Needs shift inspection Suite .# Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: s� o ktIoN\� Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 city of Tukwila Department of Community Development Steven M. Mullet, Mayor Steve Lancaster, Director May 5, 2000 Claire Madsen 12770 Gateway Drive Tukwila Wa 98168 Permit Status D99 -0172 12770 Gateway Drive Dear Ms Madsen: In reviewing our current permit files, it appears that your permit to demolish a closet and enclose one office & closet, issued on May 1, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)433 -7165 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician Xc: Permit File No. D99 -0172 Duane Griffin, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431.3670 • Fax: 206.431.3665 b 14 : '�:�ax' 1' M . ?.L LTTf SrSwa.?782YYr?b; ?treKik. CoarA Copt PLAN REVIEW /ROUTIN SLIP DEPARTMENTS: Build of gt3ivision lig] 40c, 6--2049 Public Works BOEING :EMPLOYEES CREDIT UNIT abmittal Responseito`Incomplete Letter ►rrection Letter # _ Revision # After:'Permit is Issued Fire Prevention El tructural Planning Division Permit Coordinator • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: [ica. Incomplete DUE DATE: 5 -20 -99 Not Applicable TUES/THURS ROUTING: Please Route I Z. No further Review Required n Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditionsn REVIEWER'S INITIALS: DUE DATE: 6 -17 -99 Not Approved (attach comments) n DATE: CORRECTION DETERMINATION: Approved Approved with Conditions DUE DATE: Not Approved (attach comments) REVIEWER'S INITIALS: DATE: \PR.ROUIE.DOC W98 City of Tukwila Fire Department Fire Department Review Control #D99-0172 (512) John W. Rants, Mayor Thomas P. Keefe, Fire Chief May 24, 1999 Re: Boeing Employees Credit Union - 12770 Gateway Drive Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an operable condition. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112.2. (UFC 1207.1) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 . iW:'a� °-is'r:;Y:;,. r�Syf•�;:�ti,f i � .r'.�;F a.t?TP. =.i.Y SuJ i', ,.'f:"re"G. w4"? ' i."l :K;Ak"(' 4'` " S e» a:.i ii'�i 'nY1A ,"�'ik`b u +'i�ii i Yk,u l :� i` s> City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 City of Tukwila Fire Department John W. Rants, Mayor Thomas P. Keefe, Fire Chief ' walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) This review limited to speculative tenant space only special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 'C'nnsirrrrrinn (-nini)nnr DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL • REGIST. # EXP. DATE,. CCO1 SELLEC *372ND 06/01/1999 EFFECTIVE DATE 08/20/1963 SELLEN CONSTR CO INC PO BOX 9970 SEATTLE WA 98109 F625. 052.000 (8/97) I certify that the above registration number is true and accurate as a sworn notary in the City of Seattle, State of Washington, County of King. Gary D. H -._.. MAR 21999 Date RECEIVED CITY OF TUKWILA MAY i 8 1999 PERMIT CENTER ELECTRICAL SYMBOL LEGEND m 10750100 OUrinc TaEPT4CE ti 01010010 5017T/41.£ 001 1®cwnr? ww.. MALT n to MAME 1550a5 TECIWT5Ca 0 iT:! VLL RI5Ca -15 IRNnURE TEC. 2E 0 SDCATNN , 0155•4. roc arIB.c Amato • SWRCN • Epto SWITCH S GANGED SNITCH • LIGHT SWITCH • DIMMER LIGHT SWITOI Dm x CAMERA T5054105T0 FLOOR JUNGT04 105 C1O00 .51000174 e0i TPA11 mown*. W5 ' meow memo 015004 40N01 001013 w • 407135 COIWE TON FAN CAR4DfAat 'D CEILING SYMBOL LEGEND REMOVE EXISTING 2X4 FIXTURE EXISTING 2X4 FIXTURE Lure mra suracsww ! SITE FLAN 12 6A. SPLAY WIRE - VERTIGLE AT , BAR CROSSIH& TO STRUCTURE ABOVE LEGAL DESGRIFTION GEILIN6 SUSPENSION 4 BRAGIN6 NO 904E Address: 12710 Gateway Drive, Tukwila, WA All that certain real property situate in the City of Tukwila, County of King, State of Washington, Being a portion of Lot 7 as shown on the plat of Gateway Corporate Center, Recorded in Volume 144 of Plats, Pages 23 -25, under recording number 8901230879, records of King County, Washington, and being more particularly described as follows. Beginning at the most Easterly corner of said Lot 7; thence from said point of beginning, along the boundry line of said Lot 7, S41' 46'16 "W 424.58 Feet; Thence from a Tangent that bears N28'15'14 "E, along the arc of a curve to the left having a radius of 180.50 Feet and a central angle of 76'28'58 ", an Arc length of 240.54 Feet; curve Thence tangent to the ds N48•13 44"W g a 250.43 Feet; Thence to the preceding course along the arc of a cuve to the left having a radius of 180.50 feet and a central angle of 46'18'05 ", an Arc length of 145.86 Feet; Thence leaving the Boundarx line of said Lot 7, N04•31'49 "W 41.60 Feet; Thence N41'46 E Feet; Thence N48'13' 44 "W 31.00 Feet; Thence N16'58'14 "E 333.84 Feet; To the bank of the Duwomish River. of the mean high water line as shown on said plat, thence along the said Bank of the Duwamish River, Er;sterly and Southerly to the point of Beginning. Contains 350,666 Square Feet ;�?. - - -. =j c` 1..nd more or less. 3 1/2 X 25 bAU6E STRUT ATTACH ON MAIN RUNNER O 12' -0' O.G. TO STRICTURE ABOVE 12 &A. WIRES EA IN PLANE W/RUMNER AT O 4515 ANGLE TO STRUCTURE ABOVE. 90 DEGREES APART O 12' -0' O.G. EACH WAY 4 WITHIN 4' -0' OF ALL WALLS. SUSPENDED ACOUSTICAL TILE CEILING 'T' BAR &RID NOTE. INSTALL Pow use STD. 4T -1012 (G) 1,10 UBC STANDARDS VICINITY MAC' EAGON SC,OFE OF JNORK Demo existing storage room and build new office in NW corner of the First Floor. Building standard door, hardware and relite assembly. Repair Grid and Install new building standard 2x4 ceiling tile and relocate light fixtures and power. TYP. INTERIOR WALL SECTION INDEX OF Di:AININOS A.1 COVER AN DETAILS A.2 GENERAL NOTES, CONSTRUCTION AND REFLECTED CEILiNG PLAN EUILDINO CLASSIFICATION Construction Type: Type 2, F.R. Fully Sprinkler (exist) OCCUPANCY GROUP: B, Office (exist) APPLICATION CODE: 1 .1.17 UBC with State of Washington Amendments and Tukwila Municipie Code Amendments Seismic: 3 Proposed Use: Office - No Change Land Use Zone: MI Light Industrial Tenant Improvement Approx. Floor Are First Floor 262 SF Building Square Footage 14.1233 sq, ft f FILE COPY rst,nd that the Plan Check i to.•r rnr, and Onti55 nd a; crnval of ��= .1..i�=.5 r.,. at:iht:r,'_H il'e v�Ui:!Ilot:.,` a�l• .a.Tt t_ :40 FOR_ f _0 4r ? qo1D/ 7Z -on vim RECEIVED CITY OF TUKWILA MAY 1 8 1999 PERMIT CENTER i/2 �� � b ?2 1 1 Ni RAL NOTES: All =- _w construction shall be built in accordance with the prev:ril'mg codes adopted by the City of Tukwila, riashington, including ADA requirements. • Contractor to provide 011 safety requirements of State and City, provide barriers. signs and warnings, and mairciain a safe enviroment for public. and workers 5. 1'o/terials and equipment must be kept picked up and stored out of a!II corridors, foyers and public areas. All areas not under construction must be kept free from dust noise and /or interference. 4. Cont-actor to verify existing building conditions. • All permits necessary for construction will be supplied by the City of Tukwila. 6. Contractor shall consult Boeing Employees Credit Union B.E.CU.) Project Manager for clarification of questions that arise or conditions that are encountered which ore not covered by or ore in conflict with the construction documents_ All construction shall occur between 6:30 PM and 6:50 AM during rreekClays and anytime during weekends, unless pre- approved by the $ .E.G_U. Project Manager. • Sequencing and/or phasing of wcrk shoji be coordinated with the SE.G.IU_ Project Manager. • Commencement of work b+i am! trade signifies acceptance of the sustrate work CS satisfactory. Correct previous work W later found unsatisfactory for such purposes. lrrtall o products in o workmanlike manner per manvfact- vrer' recommendations. Repair existing building surfaces where damaged or changed by new construction or demolition. Remove from site all debris related to the work and clean for occupancy on daily basis. Approval for parking and storage use must be pre- arranged with B.E.C.U. Project Manager. Gontroctor shall heave project vacuumed, dusted, glass cleaned and ready for occupancy. Contractor shall provide new ceiling tile where necessary, USG 2'X4' ONMi lilusan Two /24, Auratone, White,. Shadowline Tapered. All wood in the wall shall be of fire retardant materials. Conduit runs for electrical outlets shall be removed to Panel. Contactor to provide one marked -up set of as -built drawings prior to furl payment. All work is to be performed under prevailing wage requirements. Ali finishes to match adjacent existing finishes. FLAN A FLOOR FLAN SCALE: 1/4 = 1 _0 11 Patch anlil Repaiq'Soffit Paint al clecd corner Wail 2 1/2 ", 25 GA. MTL ;y uds 0 24" O.G. to Bottom o€ Cig Grill at I -O" appx. Type "X" GAS each side. Mat4i BIB. Std finish KEY FLAN: I 5 FOOR TUKNILA 5.E.C.U. Not to 5C-ale AREA OF WORK PLAN A ELECTRICAL FLAN NOTES: ® Remove existing 1IOv Receptacle ® New 110v Receptacle, 0 IS" AFF Two Locations New 4 Port Data Jack / Mud Ring Pull Mire ® Remove and Relocate 2x4 Fixture Two Locations ® a and b Move Stobe to new wall ® Relocate thermostats ® Remove UPS circuits from existing IIOv Receptacle ® Change existing UPS to standard house circuit ® Remove existing light and install in new closet E Existin wall to be Removed. Patch Wall a Gar et Paint to Match djacent Surface. RELOCATE FIRE XTINE ISIER Provide New and New or New or Exisitn Fire Rated As Provide Stand move Existlyg Do mo walls uildin Standard Mood Door Fror use o ar Existing 4 I He ware for d45 min. ambl . rd lite Assembly Per elevation r Frame Stain Frame, P or and Relites to Motch Buiding 4tondard I7RAJN1 NO LEENT=7 E = Approx. Exist Location R = Aporox. Relocated Position N = Approx. New Location FINISHES Replace new ceiling grid and tile 8' -6" typical ceiling height EXISTING WALLS TO BE REMOVED NEW WALLS TO 14' HEIGHT EXISTING WALLS TO REMAIN 1. CARPET F.O.I.C. 2. PAINT - Parker 5420!^= Eggshell (to match) 5. WOOD BASE - Building standard Oak, stained to match 6" H. Fix CA 11 1=1 11\ RELOGA = FIRE I 11 ■ E mil _ AF E A E -tino Sprinkler Head, is im1 0 e Relocated I. j _ :■ \ I i1 t Eiii 40 irlillRA . Alf '1 i -- a E 1 Arai IR I 14' -0° CEILING CAMERA Reuse ezistinqq Lid Connect td Exr R = RE FLAN 15 CEILIN0 FLAN SCALE: I/4 =11=011 FLAN C ELECTRICAL FLAN SCALE: 1 /411 ®I ®011 1/2