Permit D99-0193 - Costco - Tenant Improvement
• :".`.2: City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcetiter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 252304 -9063 Address: 1160 SAXON DR Suite No: Location: Category: ARET Type: DEVPERM Zoning: TUC Const Type: Occupancy: STORE Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: SPRINKLERED /AFA Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: Y Streams: Permit No: D99 -0193 Status: ISSUED Issued: 07/26/1999 Expires: 01/22/2000 Contractor License No: BARCLDCO25P7 OCCUPANT COSTCO WHOLESALE Phone: 1160 SAXON DR, TUKWILA, WA 98188 OWNER SADE PAUL +ELEANOR 585 POINT SAN PEDRO RD, SAN RAFAEL CA 94901 CONTACT MATTHEW JONES Phone: 425 -602 -4978 11820 NORTHRUP WY; i#E -300, BELLEVUE, WA 98005 CONTRACTOR BARCLAY DEAN CONST SRVCS INC Phone: 206- 682 -3223 4623 7 AV S, SEATTLE WA 98108 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: DEMOLISH SECOND FLOOR OF MEZZANINE AREA - TENANT IMPROVEMENT. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 125,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 1,875.19 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature: ;) _ Date: _DiZEL _ I hereby certify that I have read and examined his permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am aut,4lorized to sign for and obtain this development perm Signature: .eezer,-- Date: Print Name:_ /111 5W !4/ atS This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. +itt: i x0 r4 C t.e i x ne • L EiVPERM 'arp, + # " 25,2:304'-9063 k 4 4 ;k' F' k'k k, k k 1. 4* k''k; k 4 A 4 `'h R k 4 4 '4 k k k :4 k I ?rnl�t :t..orte#i .ion ;1 No ut� rtae r�i i,i bei.,,made: to the ^. ppr wi.eci:'btr: tide,: En' sneer ai+d the T�ikwi is Buy J ;cii.$),cr: iory oer mi to ir�oec1~ic�rt k ~1~t+ r tip,, nd �� Ear ive i pi tta Sh 1 1 I:al�ie spr; Tar .;to t ny , `cvPI tiori these L1ccu l rat, +{a e.. ta`}6 t' I11.�:Irif�tl ?[1l't�`ctr,�i aval.: .gibie ur3t71` 1 iri:a,'I in'4, et,tiC+tT al3r+rov,?aI' i ranted fi. Vas ty o SF +mot mi t. '. he i.��tl rye afi.:' �� perrni ar ��i�tC+r oval of an plan p sp.e T� icatit�rlat cnd coriputatl.gm.5 alidl I. °not l�l'4rcon- ; for . :.ear ari a1�4+r a�a:l � 1, riV t�i.oi.a Tori'. of anv ;0t `the t� Ct+ `i i,on of t11he l}cii.ltlir :rode at^ of any ti the': y u � ^ii rat l tlri ': No De t p S in' itC( t �7i`rr auth r itV to .Violate5or cance2''the: urc vi i,o11� co " 1 1 11.4' ..va�`l i d ::tuti .. t', SiJCCz . .. A'00'1 i e d 'O6!G ' y1 �1N .A. a �tle+i l!7 .t Ji.9L }Q k *'14 #'4'1,4 44 k.'k •4 •k k 4: k'k,b 4 k •,'4 * 4 4 4 4 A.44 /'i'.41' b k k k,4 k 4 b': CITY OF TU "WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: ' 'r ' Wdt��z Dat . . Existing use: CaRetail ❑ Restaurant ❑ Multi- family 3 Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other - Valuonde dd�� (() t5 Site Address: City State /Zip: /l GU ",yes. xoN tag /»' 7742,wft.4- wA 9fl/B13 Tax Parcel !lumber: Z5Z 3dQ-- q •9E, Property Owner: Phone: Street Address: City State /Zip: Fax #: Contractor: 7° Phone: ). *z- *2.2 Street Address: Z 7 -74-t .... ,& �oorw- City State /Zip: -Ace', wA, / Aro S Fax #: ‘p_eg) Aez - Z7Z 1 Architect: I`1uL.Y,s4.0 /y , R /7 7 Phone: Street Address: // ZO f /.vvC7 wvP W4.Y City State /Zip: noo B f./ Fax #: Engineer: /kAA ft; ofi 6 Phone: Street Address: City State /Zip: Fax #: Contact Person: M atti It M' ne: Ph (4 --Z�) baz - 4978 Street Address: // $20 / 1e2- P k/,a -.A 3av City State /Zip: et-Iv, Wisy- 9 005' Fax #: *4Z5) - 4,(Z? Description of work to be done: 17errt0 2r . _Ropy- oc meza. _e0. .\ Existing use: CaRetail ❑ Restaurant ❑ Multi- family 3 Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other - ��11 Proposed use: 11 Retail El Restaurant ❑ Multi- family Warehouse 171 Hospital ❑ Church 51 Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University in Other Will there be a change of use? p yes Cl no If yes, extent of change: (Attach additional sheet if necessary) -rerw. 4O47/7742 f a Ac- Vl r> -tz._ M,Q.i8.,Fae7-1.17 -04.G- P.P- oGY.t7Y4y - Will there be rack storage? ❑ yes 10 no Existing fire protection features: SI sprinklers ta automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: /`IO► `s.56, existing Area of Construction: (sq. ft.) 24 07� Will there be storage of flammable /combustible hazardous material in the building? ❑ yes gi no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST. FOR PUBLIC WORKS.SITE/CIVIL PLAN REVIEW OF THE FOLLOWING:. (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation Cl Sanitary Side Sewer It: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt 1!: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent f! Size(s): ❑ Water Meter Tempi! Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dafp applin accl�cj: Date application expires: la. -S -9g Appli ionnaken by: (Initials) PLEASE SIGN BACK OF APPLICA ION FORM CTPERMIT.DOC 7/29/97 ALL COMMERCIAUMULTI -FA . TENANT IMPROVEMENT /ALT: TION PERMIT APPLICA TIONS MUS BE SUBMITTED WITH THE FOLLOWING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Forn1 H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include • ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer,0or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THt STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWIy2R OR AUTHORIZED GENT: Signature: , �/ te.. �',ac - Date: //r 7 Print name: Phone: Fax N , f4z.,!�looZ.�7f�i 1425 BZZ — 41g9 M.err L ��, b= Address !I g2o Na,e7'xi��P w.�-�r. E 300 City/State/Zip j ffl e—Ervn. ,WA fleatlS CTPI:RMIT.DOC 1/29/97 ;iY.rri;.'yw; f v nP.n; INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, ' :188 11TNO. )431 -3670 Pr ject: Type aspect' Mt Ca<C7001C7 C ,12/Z? Kral" Ariress° 54x es Date cal ed: Special instructions: Date wxI1 ddq �C,C�f a.m. p.m. Rp s r etr–c.vitn e. Phone: -42 /26(--- 6 UV Approved per applicable codes. Corrections required prior to approval. COMMENTS: Mt Ca<C7001C7 C ,12/Z? Kral" (ifs l<9, 4 v eil/1de'...b //t (S PPc776tAi5 77'16 GCi — /S C651 °,46?" 4.41t> 7''y ,ce V44e ei e9' -42 /26(--- 6 %i iv /t.. '4c- ) __s __1, E - Date /X, $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No: Date: City of Tukwila • John'.W. Rants, Mayor. •Department of Community Development Steve Lancaster, Director PLANNING DIVISION COMMENTS DATE:: June 17, 1999 APPLICANT: . Mulvanny Architects RE:.:. D99 -0193, COSTCO Wholesale ADDRESS: 1160 Saxon Drive This memo is to revise my previous comments on D99 -0193, COSTCO demolition permit. The application is complete and may be routed for review. The parking plan I requested will be submitted with the actual building permit application, which will be submitted next week. c:\carol \general \d99193 -2.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 roil GO .77 1J• 4b r•rt LUJ I l.0 LGUr1L ea•BJHd May- 24.99 • • 12 r b6P r •N.i'QrmL -: w. `tt}".ti C ?- $' LW .7 "%:1.3 ::^j7",�; 4QJ JJJ 0114 IU vote-mlLJ WW2 • C.It• YJJ 6t:4T 66, PE AdW FA . 02' c-•, Pl 4J144tLN1 Crow-0 (uVIJo.atnY .) May 7, 1999 Writers Direst u Via Airborne Express Robert M, Miler COLLIERS INTERNATIONAL. 5050 Hopyard Road SUlto 100 Pleasanton, CA 94480 Ateent;On: Robert M. Miller, Vice President Re: REVISED Proposed Costco Wholesale t•Cos Dear Bob: Isaslsta.it :• too') Remodel Qs we discussed, Costco would like to make certa warehouse, including the demolition of the second floor being used as a Costco supply room, AB you have wen previously sent to you on ft/larch 23, 1999. the majority are in the area where Coatco previously operated its op In this area, Costco would like to alter the buiidln� eouIc mcnt for a new test concept, The new concept in�C and tea bottling operation whore Costoo would bottle an water, Soda and tea to its membera• The new concept tortilla, potato chip and burrito operation where Como Its Own tortillas, potato chips and burritos to its own me in alterativrra to the which is currently from the plans we of the alterations cal lab. We are excited to test this new concept and wou appreciate the Sides approval of the alterations rc allow concept et rho Southcenter warehouse. Also as you req will serve as Casten's acknawledyrnent and contlrmatior the lease term and at Landlord'S option. Cot wilt res the condition In which it was prior to the inutulletion of It the Sides approve of our propused plan, please indicate their approval by eignIng below end return the c to accommodate ludas a watery sods sell its own lap includes a vouid make ana sell ambers. Certainly V6 to tariff this new +vsted, this letter that at he end of Ire the building to ese improvements• have the Sides �iginat to ma. 999 Coke Drive, Issaquah, Washington 98027 • 42 (313 -8100 I 241 ? :ei 66151; ra 'K@w t 'ON 3101,41 :3'1'11W 'N Lidami : WOW 1 PA W.4CT •hGl CGGT ►,9 •if1011 031.* l'IFIT ' 413 h-t< Lt.UHL cleD .11J 0114 FRum ROBERT M. MILLER gr PHONE NO. 1141:; may- 24 -12. 1 SSP u 70444414v r . it Mai . 25. 1999 07: 051H 2,01,010 1140.• - Awe it "MY 7. ties • Please 'feel fro, to ol% me if you hove env questions or need theiditiortal information. Velar prompt attention to MIS setter Is certainly • appreciated. Thank you. • • • Very truly yoUrs, COSTCO WHOLESALE • Gail E. Taubol Director 01 Property Management ACCEPTED AND APPROilED PAUL SADE AND ELEIOR SADE, AS T THE RUSTEES OF AUL AND ELEANOR 55 TRUST E4 Waia1Z1 4,0 P flu MAY 25 '99 08:09 darniw •w .1.414Cid Tniol17617.P l ve* �rttie'i" ukF��. d 15;sAmm f a l.:e,. • Prrn'14-- Onorci PLAN REVIEW /ROUTIN LIP TIVITY NUMBER: D:99 -0193 DATE: 6- XX Original Plan Submittal Response to Correction. Letter # Response =to:: Incomplete; Letter Revision #: _ After' Permit Is Issued, DEPARTMENTS: Building Division 0 17-iiq Public Works kgm Ala G -lo Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete `it''] Incomplete Comments: TUES /THURS ROUTING: Please Route Routed by Staff n (if routed by staff, make copy to master file and enter into Sierra) DUE DATE: 6 -10 -99 n Not Applicable No further Review Required n REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWERS INITIALS: DUE DATE: 7 -8 -99 Not Approved (attach comments) n DATE: CORRECTION DETERMINATION: Approved n Approved with Conditions DUE DATE: Not Approved (attach comments) n REVIEWERS INITIALS: DATE: 1PR•ROUTr.DOC 6/98 Wee 0�"V� ea fe City of Tukwila Fire Department. Fire Department Review Control #D99-0193 (512) John W. Rants, Mayor Thomas P.14efe, Fire Chief • June 16, 1999 Re: Costco Wholesale - 1160 Saxon Drive Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Gates and barriers shall be openable without the use of a key or any special knowledge or effort. Gates and barriers in an exit shall not be locked, chained, bolted, barred, latched or otherwise rendered unopenable at times when the building or area served by the exit is occupied. (UFC 1208.2) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 ?5«ita e'r'r Uf.�t eeaYti"act'.i tigAtN,Y, City of Tukwila Fire Department Page number 2 L�f John W. Rants, Mayor Thomas P. I eefe, Fire Chief 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or part)rtions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (UFC 8509.3) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 City of Tukwila Fire Department John W. Rants, Mayor Thomas P. Xeefe, Fire Chief ' 5. Required fire resistive construction, including occupancy separations, area separation walls,.'exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 • ••••r:•••4,0 Department of Community Development Steve Lancaster, Director 1908 PLANNING DIVISION COMMENTS DATE: June 10, 1999 • APPLICANT: Mulvanny Architects RE: D99-0193, COSTCO Wholesale • ADDRESS: 1160 Saxon Drive Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revision, Carol Lumb is the planner assigned to the file and can be reached at 206-431-3661. 1. The materials submitted do not indicate compliance with the City's parking standards for the new manufacturing space. This issue was discussed at the Pre-application meeting on May 5, 1999. Please provide calculations on the number of parking spaces - needed for the new manufacturing use (including loading spaces) and distinguish these identified spaces from the number of spaces needed for the retail use on the site. A copy of the parking standards is attached. cAcarohgeneral\c199193.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (2061 431-3670 • Fax (206) 4313665 June 14, 1999 City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director Matthew Jones Mulvanny Architects 11820 Northup Wy, #E -300 Bellevue, WA 98005 RE: Letter of Incomplete Application #1 Development Permit Application Number D99 -0193 ' Costco Wholesale 1160 Saxon Drive Dear Mr. Jones: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on June 8, 1999 is determined to be incomplete. Before your permit application can begin the plan review process the following items need to be addressed. Planning Division: Carol Lumb, Associate Planner, at (206)431 -3661, if you have any questions regarding the attached. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit four (4) copies of each document. In order to better expedite your resubmittal a `Revision Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206)431 -3672. Sincerely, GC_ Brenda Holt Permit Coordinator encl File: Permit File No. D99 -0193 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL RECEIVED my - 3 1993 1 REGIST. # EXP. DATE CCO1 BARCLDCO25P7 10/01/1999 EFFECTIVE DATE 10/27/1998 BARCLAY DEAN CONST SRVCS INC 4623 7TH AVE S SEATTLE WA 98108-1719 AGO9. ACOUSTICAL ADJ ADJSTABE, ADJACENT A. , ANODIZED APPROX. APPROXIMAT D, HOARD H✓-DG. BOLDING BL ELOCK 51.K0. .0 04.1. HM SEAM HOT, BOTTOM HTK $E7WENi LE CATCH BASIN CA. CAST IRON CAP, CAST M PLACE C CORER 111. C.AR, a& CEILING CMJ ATE MASONRY WIT COL. C41I194 GC'.C. CO'NGRVE AN, CORM.. COST. corism TION CONTR. CONTRACTOR C.T. CERAMIC TILE DO- DO,JHLE DTI. DETAIL DP. DRRKRG POUNTAN D5. DOYAt9POJf DRY., DRAW. EACH EFS, EXTERIOR FN. SYSTE35 EAF5, EXTMOR TOM F+7Ti5H 515755 S3.BV, ELEVATION, ELEVATOR ELEG. ELECTS.. VOL EfiGL05,R. EQ. DUAL E., EXHNY-T EXP. EXPANSION EXT. EXTERIOR FD. FLOOR DRAIN r FONLATION FF FACTORY FINISH F. FLAT HEAD SCREW 3, FLOOR F1D. PJRNISFED 1 INSTALLED BY ONNER PAPP. FIEER REINFORCED PLASTIC PANB.(5) FT6. FOOT@. GA GA16E SAL, GALVANIZED GT GALVANIZED IRON GIP 611 LATH ! PLASTER GY8 GYPSUM WALLBOARD, GYPS'.M BOARD HH. HOSE BIBS HC. HANDICAPPED HM. HOLLOW PETAL f JZ. HORIZONTAL HR, HaE16NT KR. HEATER INSLL, 1161.1ATION JTJJTS. JOINTJOINTS LAM. LF, LID MAC. MAX H95. MECH, MEZZ, AATAP ME6. ABBREVIATIONS CON., LENGTH LAMINATE, LAMINATED LINEAR FOOT, LINEAL FOOT LORD LIGHT ?EIGHT Mh5Oarr MAXIMA METAL WILDING SUPPLIER MECHANICAL MEZZANINE METAL MAhUFACTU RING MAMIFA/TDFO MN, MIN MISC. M.O. MR MAIL. MT. MTG. N.I.C. NOM, NITS. OA. O.G. ON. OP'6. OFP, PRl P.P. PERPENDICULAR PL. FATE, PROPERTY LINE FLASIAM. PLASTIC LAMINATE PLY/D. PLYWOOD BEG. PLIF581N6 PNL PR FROJ. FRV MANHOLE S.G. MINIMfM SFR. MISCELLANEOUS SIM. MASONRY OPENING SAO MOISTURE RESISTANT MULLION 5,1.0. MOUNTED S.I.V. MOUNT. S.O.IC. NOT IN CONTRACT NOMINAL SPECD. NOT TO .ALE SO, OVERALL 55. ON CENTER SST OVERHEAD STv. OPENING STL. OPPOSITE STRWT. PARTITION SUfiP. SYS. T L TEL. T TA6 PANEL, PANELING PAIR PRO -FLT PRE`.RE F'ibTAJG:F. VALVE PT. POINT O.T. QUARRY T. OTR QUARTER R RADIUS RD. POOP DRAIN R.L. RAIN LEADER RECD. RECEIVED REF, REFRIGERATOR REINF, REINFORCING RFbD, REWIRE R.O. RCV5/1 OPENING v,HFD VAR,II T. W/O Hi. WP WR WT. KKK Yhn SOLID CORE SHEET SIMILAR SUPPLIED 4 INSTALLED BY CONTRACTOR . LIED / INSTNJ.FD BY OWNER .PPLIED / 06TALLED BY VENDOR SUPPLIED BY 0141ER INSTALLED BY CONTRACTOR SPECIFIED SO ARE SERVICE SINK, SANITARY SEWER STAINLESS STEEL STANDARD 51E. STRUCTURE, STRUCTURAL SU5PGDED SYSTEM TREAD, TOP TOP t BOTTOM TELEF.. TEMPERED TONGUE 4 GROOVE 'YaTr. ,47 UTILITY U!.IFORM WILDING CODE vii/.COMPOSITION 711E VERTICAL WITH WITFi,.T WOOD WINDOW WATERPROOF WATER RESISTANT WEIGHT YELDED WIRE MESH WELDED WIRE FABRIC TAM" r:aAIM a 1NflOL E 1160 SAXON DRIVE TUKWILA, WA 98188 NORTH ARROW DOOR MARK -Dew rntt - REFER TD SCHEDULE WINDOW MARK /�- D \/ FAIL IL ENT IF MAT Iw <2> MARK SCREEN /LOUVER SHEET MERE DRAWN WALL SETION / - \ DETAIL IDENT SHEET WHERE DRAWN BUILDING SECTION DETAIL hDEMIFIGTIOI SHEET AWERE DRAWN FAD VIBUINCATION AW CQO RDINATIOl. GENERAL NOTES I. SURVEY DIMENSION. D1140610. OF SITE CONDITIONS ARE FROM SURVEY BY OT}E196. TIE ARCHITECT BEARS NO RESPONSIBILTY FOR ACCURACY OF SAME, 2 EXISTING UTILITY LOCATIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE SIZE AND LOCATOR OF ALL EXIST. UNDERGROUND AND ABOVE GROND UTILITIES, EXISTS UTILITIES a YYN HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AtD ARE SHOWN FOR CONVENIENCE OH-Y, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL RUNTY LOCATIONS NOT Sii0XN. CARE SHO.LD BE TAKEN TO AVOID DAMAGE OR DISTURBANCE TO B OST. UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE TO THE UTILITY. 3. THE CONTRACTOR SMALL NIN T THE ERMINE& OF ALL TRADES FOR OPEG$ THROUGH SUBS, ROOK , PALLS CEILINGS, O D ROOFS FOR CULTS, PIPES, CONDUIT, CABINETS, AND 6O11PFEFIT AHD SMALL vexFY THE SIXES AM LOCATORS WTH SUBCONTRACTORS. 4. MAINTAIN STORE OPERATION WRING SELECTIVE DEMOLITION 5. MAINTAIN UTILITIES, COMMUNICATION AND SECURITY DURING TE DEMOLITON PROLE%. 6. ALL SALVAGED MATERIAL IS TI£ POxFSION OF THE MI ER. 7. PROVIDE TEMORARY CLOSUR-S FOR ANY OPBNIN6/ENPOSURE OF THE WILDING EXTT3210R. COORDINATE WITH BUILDING SECURITY, I. DO NOT SCALE. THE DRAWINGS TO OBTAIN DI 136IOt6. WRITTEN DimetsIONS 60`!F - USE ACTUAL FIELD F€A°.UREMENTS. NOTIFY TtE A.RCiPTECT P ANY D6CF.PAPCIES ARE FOUND. 2. DIMENSION. ARE TO TE: ROOM, MARK - A - ROOI NUMER COLUMN GRID - CENTERLINE CF COUR416 OR GRID - CENTERLNE OF °PERIN. - CENTERLINE OF PARTITIONS - FACE OF CONCRETE OR MASONRY RNOMMNALJ - FACE OF SHEATHING AT EXTERIOR STUD WALLS - FACE OF FINISH AT EXISTING FINISHES J GENERAL DEMO NOTES FIELD VE4KCATION AND COGRDMNA110% I. CONTRACTOR SHALL INCLUDE AND PERFORM ALL DEMOLMON WORK REQUIRED TO ACCOMODATE NEW WORK 2. CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING REQUIRED DURING DEMOLM. WORK AND UNTIL NEW WORK 15 IN PLACE. 3. UNLESS DETAILED OF SGFEDULED OTHERWISE, ALL AREAS AFFECTED BY DEMOLITION WORK SHALL BE PATCHED AND /OR REPAIRED TO MATCH EXISTING ADJACENT. - AGES AND FINISH. REPAIR AFFECTED AREEAS A5 REQUIRED TO RECEIVE NEW WORK 4. PROTECT ADJACENT SURFACES NOT SCFEDIILED FOR DEMOLITION 5. CONTRACTOR TO VERIFY ACCURACY AND EXTENT OF CONDITIONS PRIOR TO BIDDING DEMOLITION WORK WHOM ON THE DRAWL.. 6. COORDINATE WITH OMER THE SALVAGING OF ANY MATERIAL. LEGEND OF SYMBOLS , DIMENSION i aF AUSDVRY R CONLPETE r�.ERL�E STRUCTURE. INCANDESCENT LIGHT FIXTURES CE IL LNG MOUNTED CH WALL IAD.TED GRAVEL GRADE ELEVAT ION ® RE... 1250 PLASTER a LATH NEW OR FINISH GRADE aw UPICC ' Ex 1ST hxG GRADE FLUORE rJI LIGHT FIXTURESD PLYAOOD REVISION DI ACCESS PANEL RIGID INSULATION SPRINKLER MAIN SUPPLY DIFFUSER BATT INSULT I ON mug, ESTER O xaDD LELBER PROPERTY LINE El FENC, OS SPEAKER WOOD OLaaKlxc l � • -• -• -. 0 60 WOKE DET..CTN. E FINISPEO ,- - -- FINISHED ® ACOUSTICAL TILE EXIT Slat ELEVATION DETAIL IDENTIFICATION CONTOURS O • SPR I KKLER HEAD STEEL SHEET NNERE DRAWN I 50' -0 t FL. ' OR WORK CONTROL TUM POI NT / / CONTOURS 0( EXISTING ExIGw NC � ALLAN MAI loA sxRIKKLER HEAD ARCHITECTURAL T'8-I Sw GNU QID CIVIL ENGINEER TITLE SHEET SITE FLAN DEMOLMON PLAN BMAAGED DEMOLITION FLAN (FAN FLOOR / OPTICAL AREA) ENLARGED DEMOLITION FLAN (BAKERY / BREAK ROOM) 1 -5 OWNER ARCHITECT STRUCTURAL ENGINEER MECHANICAL ENGINEER ELECTRICAL ENGINEER FIRE SPRINKLER ENGINEER REFRIGERATION ENERGY MANAGEMENT INDEX OF DRAWINGS VICINITY MAP STRANDLOR BL St 5 180th St TUKWI PKY ENGINEERS NORTHVEST 6869 WOODLAWAN AVE. NE SEATTLE, WA 98115 ph. (2O6) 525 -7560 FUSSMMAI CORPBRAT1. 7272 1ST AVE. SOUTH SEATTLE, WA 98108 ph. (206) 163 LOCAL CONTACT, MANE COMPANY 2021 152ND AVE. NE REDMOND, WA 90052 ph. (4251 643 -4310 BLVD SAXON COSTCO WHOLESALE 999 LAKE DRIVE 155A0UAH, WA 98027 ph. (4251 313 -6704 MRVANNY PARTNERSHIP 11820 NORTHAP WAY, NE -300 BELLEVUE, WA 98005 ph. (4251 822 -0444 PROJECT MANAGER: T.E. 14900 INTERURBAN AVE. S. T,KWILA WA 98168 ph. (2061 241 -2012 TE. LNG. 14900 IN'TERIRBAN AVE. 5. TUKWILA WA 98168 ph. (2061 241 -2012 TVA 2820 CANING DE1 RIO 50U111 51117E 200 SAN DIEGO, GA 92108 ph. (619) 296.5666 BARGHPL.iEN .01111 ERS 1821572ND AVE. 5, KENT, WA 98032 ph. (425) 2514222 ORILLA SW 27th St S PROJECT DIRECTORY SW 34th 5t PA %3 A Tat portion of 6overmmnt Lot I of Section 35 are Government Lct I a< _actin 36 and 6wernmanc Lot 8 of Sectonn 25 0Lnd Sat parton of the southeast quater of the southeast quarter of Section 26, all n Toe tshlp 23 North, Rage 4 East, KM, In Kng Country Washington desalbed as follows: Begiming at the northeast corner of said Government L. 1 of 5ectbn 35; thence south OI°941° west along to east Ina of Government Lot I of sold Section 35 a distance of 8238 feet to Mo true Pont of beg6ng; thence north 88°06'21° west a distance of 16724 feet; thence north 01 °513W east a distance of 8355 feet; :.once na l& 01 °4729' east a distance of 515.60 Peet; thence along a veva to the right having a rod. of 300.00 feet, on arc distance of 99.43 feet trough a central Mhgle of 18°5976 ° ; trance south 68123P east a dbtonce of 72322 feet; thence south 0I °47'29° west a distance of 47187 feet to the west margin of the Janes Orbtereen Rood; thence 8065 30°24 west along sold west margn a distance oP 6048 feet; thence south41°3221° west along sold west mcrgn a dist.. of 17448 feet these rar. 68°0821° west a distance of 52622 Feet N tlha true poDt oP Segmng. TOGETHER WITH a penes d aid Irrevocable Tian- exclus56 easement over the 501lowng described 30 foot strip of lend, camorctg at the east Me of Andover Park East, proceeding easterly to the cast Iina of the gent 's (Parcel A) property, said 30 foot strip of land Is described as Pollo. That parton of the southeast quarter d the southeast quarter of SeOtbn 26 and Goverment Lot 8 al Seaton 25 all In Towrlshp 23 North, Rase 4 East, RIM., n the Olt, a1 Tukwila, King C unty, Washington, described as Wk.: Begimng ot 0 sostheast caner of *Oki southeast gaerter of the southeast ovator of Sect. 26; thence north 8744.° west along the south Ina of sold southeast gucrter of the southeast quater of Seaton 26 a dlstonce of 166.45 feet; thence north 01°4729° cost a db.. of 515.60 feet; thence along a cave to the right haying a radws oP 300.00 feet, arc Olsten. of 99.43 Peet Seough a central ogle of 166926° to to true point oP bagirning; Thence mirth 88 °1231° west a distance of 257.91 Fact W to easterly nergn of Andover Pak East; thence along sold easterly margin along a curve to the right the center of whisk bear so. 71729'01° east Meng a rad. of 270.00 feet, on arc distance of 2033 feet to a pout of reverse curve; thence along a curve to to left having a rad. of 550.00 feet, an arc distance of 11.46 feet; thence seMh 88 °1231° east a dot Yee of 97083 feet; thence south O° 4729' Host a distance of 30.00 feet to the northeast corner of the drove desr.r .ed parcel; thence north 869231° west along north Ina of the dove desalted parcel a distance of 72322 feet . the thus poet of bagvesg, PARCEL B. That portbn of Goverment Lot I in Seatlen 35, To ooNIp 23 North, Range 4 East, RIM., 3 the 05 of Tues.,, KRig 02206 .. 00653505 d.scrlbed as follows: Beglrnvg at the northeast comer of sold Goverment Lot 1 of rxctlon 35, thence south 01'19'01' west along the east Nine of sold 6overnme t Lot I a 40tahce of 8238 feet; thence north 68°0621° west a dn.,. of 16724 feet to the true point of beginning; thence continw1g north 68 °0621' west a dbta1ce of 253.00 feet to Se east Ilse of Andover Park East; thence north 9' east along said east line a distance of 48.00 feet; thence sot& O00O0 68°0821' east a db.. of 253.00 Feet to the west line of Parcel thence south 016139° west along said west line a distance of 48.00 Feet to the true point of bsgmng. PARCEL. C. That pardon of Government Lot I, h Section 35, Township 23 North, Range 4 East, WM., In King County, Washington, described as foliows: Beglmng o the northeast carton of sold 6ovemment Lot I, thence Thoth 81°44'06° west along the na-S Ina thereof 166.45 feet to the centerline of CMST. P P RR RAN easement; Nonce south 1°5139' west along sold centerl52 8355 feet; thence north 88°0821' west 25340 feet to the true point of beginnIng of this description; thence south 88 4 08'21° east 226.00 Feet; thence south 86 °25'18° west 211,95 feet; thence south 37°4351° west 25 feet to a point from which the Also paint of beginnng bears north I °51' 39' east; Lorne north I acct to the true poet oP 609101ng. BUILDING DATA EXIST, BUILD. AREA EXIST, ABANDONED OPTICAL- 1ST FUR, CONVERTED TO STORAGE RM. (DEMO) 400000/26 OPTCAL 2ND ELIXIR TOTAL M3+4 WILDING RACK COUNT: GROCERY RACKS CENTER SECTION HAPDLINE RACKS NOTE . EXISTING CONDITIONS TO BE FIELD VERIFIED. q LEGAL DESCRIPTION SITE & BLDG. STATISTICS SCOPE OF WORK 190,956 SF. 13212 5F. (15212 5F) 204228 5F. 250 I8,�80 S.F. 208 CITY OF TUKWILA APPROVED D' E 0 7 33 TTDSG D1VTIXTN AS NOTED SELECTIVE DEMOLITION IN RREPARATION TENANT IMPROVEMENTS FOR NEW PRODUCTION LINE, MUINANN A 2 C w 1 - _ C T_ ARCHITECT: 3760 PROJECT NUMBER: PROJECT MANAGER: DRAWING DATE: DRAWING FILENAME: DECEIVED CENTER REGISTER SLAY QUINN LEE STATE OF WASHINGTON COSTCO WHOLESALE 1160 SAXON ROAD i,!CWIA, WA 9818R- JERRY Q. LEE 93 -04 <d MATTHEW JONES 5 -17 -99 30 «DTS -1 REMODEL DEMOLITION PLAN C �QIG� TS -1 EXIST. TO REMAIN FEN WATER TOYER ENTRY EXIT EXIST. BUILDING AREA EXIST. ABANDON OPTICAL 15T FLOOR CONVERTED TO SUPPLY ROOM (DEMO) ABANDONED OPTICAL 2ND FLOOR TIRE CENTER NEW TOTAL BUILDING 1 S.F. AREAS OF WORK TYP. L EXISTTNG RECEIVING DOCK EXIST. TIRE INSTALL. ABANDONED RECEIVING DO`K7 o 4 E11 LOADING DOCK7 EXIST. CURBS STRIPING TO DE REMOVED TUKWILA , WASHINGTON EXISTING REGIONAL OPTICAL FACILITY 6x941 .BB' 08'3i'W I COSTCO WHOLESALE SAXON DRIVE - ASTTNG LANDSCAPE ISLANDS AND PARKING STRIPES TO REMAIN, YEP. # CFNOO l EXIST. PAVED /GREEN RIVER TRAIL j ■ DD Iq CITY OF TUKNILA APPROVED JUL II 7 1995 AS ROIEU BUILD PIC ,VISION COSTCO TUKWILA, WA WHSE #6 1 160 SAXON DRIVE TUKWILA, WA 98188 MU LVANNY A R C H I T E C T S RECEIVED Clrt - 1131 , :ILA PERMIT CENTER 0 20 40' 80 :,. Va SCALE: 1" = 40' -0" BUILDING REMODEL CONCEPT SITE PLAN so -, JUNE 8, 1 9 9 9 93 -044 D SALE V = 20 FIRST FLR DEMO FLAN SGTLE: I " = 20'-0" NORTH Q SE FLR DEMO FLAN pp NORTH 59' 50' 50' T U (a) 50' 50' (c� • • • • p D0'0 Iq3 0 ■O' 20' 40' 80' CITY TU &A AN PROYED JUL 71999 AS NOTED BUILDING DIV1310N E MU A ERMIT CENTER ARC,ITECT: .ERR Q. LEE 3766 REG:SHR`D { AIVE1Efi l �f ! ' �/ 7ERdY QU1NN L'cE I S'Ait WASHINGTDY PROJECT,MBER_ 93 -04, PROJECT MANAGER: MA EW:ONES DRAV,FIG DA DRAW NG FILENAME: 3044,1 -1 COSTCO WHOLESALE 1160 SAXON :ROAD TUCWIA, WA 9818E REMODEL DEMOLITION PLAN D-1.1 O EXISTING OPTICAL ‘,2,) FIRST FLOOR DEMO PLAN a NORTH 50 TO GRID LINE 5 24 50' 15 -7 I/2' EXISTING OPTICAL n SECOND FLOOR DEMO PLAN e-N / SCALE: 1116" = 1'-6" NORTH 50' 104' -2' -b 45, 42 -21, 17-5' 50' O �J 50 HAU S TO EE DEMOLI5:100 VOU.S TD RLWIN DEMO KEY NOTES 1,51645 STEEL RACKS REMOVED B' OWETR 065TINS IRE SALES RACKS REMOVED BY OWf3R DEMO MO DL _-_ OF 0.650146 OYER.. METAL DOORS AND APFMTVWL^ES. GEM AtO DLR _-_ OF PESTI. FETAL STAIRS. ANDD CFal5014S STUD HALL MTN 511 YWlBOARD EACH SIDE OLIO AtO DISPOSE OF FJGSTING SSSPE.ED ACOUSTICAL COONS TILE, FETAL T{AR5 AND ALL PFPHtnNANC.. DEMO Ato DIS OF EXISTING FETAL TOILET PARTITIONS. DEAD Mo DISPOSE OF EXISTING WOOD STARS. REMOVE D ISINS 5OL10 CORE WOOD VOLRS A,b WCGO FRAMES. 17810 AND DL:POSE OF D IMINS WALL HAG HATER CLOSETS. DEMO MD DISPOSE OF EXISTING WALL HAG URINALS. DEMO Al. OW,.E OF EXISTING WALL RAG LAVATOw6. GeV A. DISPOSE OF EXISTING LAVATORY/OOINiHR NOT USED RE . MO RELOCATE EXISTING COFFRU OR PER OMERS INSTRUCTIONS. DEMO A. 0ISP05E OF oasn1L cHRAMC TILE TO FACE OF CONCRETE FLOOR De. AND DISPOSE OF EXISTING COLL.. 0540 MD 0,05E CF EXIST. WOOD STAGE AND STAIRS. DLO AM DISPOSE OF EXISTING CONCRETE STAIRS. DEMO MD DIB.C5E CF EXISTING STOREFRONT FRAME AND GLAM.. DO. AND DISPOSE OF EXISTING LOW WALL MTh St. EACH SIDE g DEMO AND DISPOSE OF EtlSTRG OtD PLOP) CONCRETE FLOOR SLAB, EEGTRICAL WIRING s MIMES AND FN.'04HO RX7LRLS CAP ALL REHM.. LIKE. FLT 20 6IBB SE!/. FLOOR CONCRETE SLAB IS TO REMAIN , SOT USED ® NOT U60 d=1 DEMO MO DISPOSE OF EXISTING PLYWOOD FLOOR MD VCT (AND ALL THE B/PPORTINtS STRICTURE BELOW) • Dto ANO p.'_P6:E OF FJGSTNS SID W.., HO, 6,0 EKH SIDE TO :0 ABOVE FIWSH ROM • DEMO LC/21%7:F EXISTING YKf WUCAL sY5Tert ING.IAIN6 ow, PIPES R7 F T OP UdT TO RHNVN g RELOCATE MD HAINTMN OPERATION OF EASTM6 BOILER ATV 001.0.RUSORS IN PREPARATION FOR RE.TALLATION ON PRO/PO.0 MEIIANRE (COORDINATE WIN PS;H®LlE FOR RIME REMODEL) RELOCATE ANC; MAINTAIN OPERATION OF EXISTING ELECTRICAL PANELS IN PREPARATION FCR RENSTALLATI, ON PROPOSED MEZZANINE WALL LEGEND Casrca MU LVANNY A R C - I r P C T S ARCHITECT: RECEIVED cm o =ruff' +1'�' PROJECT NUMBER: 93 - «d PROJECT MANAGER: MATTHEW JONES ]RAW0ICI DATE: 4.14.99 DRAWING FILENAME: 304,60-2 COSTCO WHOLESALE 1160 SAXON ROAD TUKWIW, WA 98188 JERRY O. LEE CITY Of TUI(WILA - APPROVED JUL 0 7 199 REMODEL AS N0IED EXIST. FLOOR. PLAN 'U"IIl DVt lON & OPTICAL AREA DEMO. PLAN q3 D1.2 DEMO KEY NOTES p ems - rt. STEEL RACKS TO. REMTlED (GOOfmMATE WI 4 ow.. E2 SALVAGE Darn. CXMPF@4T FOR POSSIBLE REIIGTALLATIOH Aro USE (COORDINATE HIM OWER) ® D GSTRL GHARUIK FENCE TO. REMOVED. (COORDINATE WITH OW Q Ix. AM DST'S.OF Darr. SILO WALL NITH arr^ 4 WALLBOARD EACH SIDE 5❑ RE.VE AND SALVAGE EXISTIHS SOLID GORE MOD DOORS AND moo FRAH6. © DO40 MD oar,.:E OF earn. mini. DOOR AND FRAM El DEMO A. DISPOSE OF EXIST. LAVATORY MD COUNTER El NOTE ❑5 DE. AND DSPOSE OF FADERS FEL/4WD, AND EL...TRIG. FIXER. AND RIMS TO SORGE. GAF ALL ADTIVE LRLS TO REMAIN WALL LEGEND WALLS TO BE DEMOLIS' ®. WALLS TO REMAIN SCALE, VS" = 1 -0« EXISTING BAKERY DEMOLITION PLAN irN NORTH EXISTING BREAK ROOM DEMOLITION PLAN r SCALE: V8" = NORTH H f H LL —L1 n 1 ± ± H L_I —LJ ,CT-0 TO ERIO UNE IO I II EXISTING LUMBER AREA DEMOLITION PLAN SCALE: I/8" = I' -O" NORTH GIP, OF TUNWI11 APPROVED JUL 071999 AS NOTED U107OIL E MUL'VANNY n i C I T E C T S .f FECcI4E CIT' OE TDIC.':1V� ARCHITECT: JERRY Q. LEE PROJECT NUMBER: 93.04 PROJECT MANAGER: MATTHEW JONES DRAWING DATE: 4 -14 -99 DRAWING FILENAME: 304 -3 COSTCO WHOLESALE /�//��/L� 1160 SAXON ROAD D C0( TUKWI A, WA ?9188 /Vl' ✓7 REMODEL ENLARGED DEMOLITION 1.,1,13.0t; PLAN D -1 a3