Loading...
HomeMy WebLinkAboutOrd 0652 - Requirements for Emergency Service for Elevators (Repealed by Ord 2703)City of Tukwila Washington Cover page to Ordinance 652 The full text of the ordinance follows this cover page. AN ORDINANCE adding Chapter ., 20 to the re- quiroments fox emergencyservice .ator Ordinance 652 was amended or repealed by the following ordinances. ion(s) Repealer Repealed by Ord #� 2703 CITY OF TUKWILA WASHINGTON ORDINANCE NO. 4Q_ AN ORDINANCE adding Chapter 16.20 to the Tukwila Municipal Code, establishing re- quirements for emergency service for elevators. THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON DO ORDAIN AS FOLLOWS: Title 16 of the Tukwila Municipal Code is hereby amended to include Chapter 16,20, as follows: 16.20.010 Application This chapter shall apply to every elevator in all new buildings in excess of six stories or Sixty Five (65) feet and in all existing buildings in excess of eight stories or Eighty Five (85) feet in height above the highest street level providing practical access to fire fighting equipment, in which buildings all elevators have automatic operation. 16.20.020 Requirements Every elevator to which this chapter applies shall be designed and equipped to operate as an emergency service elevator, as follows: A manually operated "ON -OFF" switch shall be provided inside the car, on the same wall as, or adjacent to, the operating panel. Such switch shall be enclosed in a fixture with a "break- glass" cover, shall be located not less than five (5) feet, nor more than six (6) feet, six (6) inches above the floor, and shall be clearly labeled, "FIRE EMERGENCY SERVICE" The switch, when operated and placed in the "ON" position, shall remove the car from normal service and place it on emergency service whereby the car shall then be only manually operable from the car station buttons until the emergency service switch is returned to the "OFF" position. In elevators equipped with a photoelectric cell device which controls the closing of automatic power- operated elevator doors, the emergency service switch, when actuated, shall also render the photoelectric device inoperative. 16.20.030 Waiver The chief of the Tukwila Fire Department may waive the above requirements for any elevator designed for limited or restricted use, serving only specific floors or a special function. this ATTEST: APPROVED AS TO FORM: PASSED B THE CITY COUNCIL AND APPROVED BY THE MAYOR day of 1970. d CITY CLERK CITY ATTORNEY PUBLISHED IN THE RECORD CHRONICLE f)eae-YYL b 1/ 74 MAYOR