Loading...
HomeMy WebLinkAboutPermit D99-0228 - Pioneer Ship Supply - Storage Racksd99-0228 1177 andover park west Pioneer Ship Supply City of Tukwila k (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 352304 -9097 Address: 1177 ANDOVER PK W Suite No: Location: Category: AWSE Type: DEVPERM Zoning: Const Type: RACKS Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: Contractor License No: EASYUSS083Q5 OCCUPANT OWNER CONTACT CONTRACTOR Permit Center Authorized Signature: cw✓ DEVELOPMENT PERMIT Permit No: Status: Issued: Expires: .0 South: .0 East: .0 West: .0 Sewer: TUKWILA Slopes: N Streams: D99 -0228 ISSUED 07/27/1999 01/23/2000 Occupancy: WAREHOUSE UBC: 1997 Fire Protection: SPRINKLERS PIONEER SHIP SUPPLY Phone: 425 -453 -1600 1177 ANDOVER PARK W BLDG. B, TUKWILA, WA 98178 WAREHOUSE PROPERTIES ASSOC Phone: (206)775 -9127 300 ADMIRAL WY, EDMONDS WA 98020 MATT PREVOST Phone: 253 - 395 -2033 8731 SOUTH 212TH., KENT, WA 98031 EASY UP STORAGE SYSTEMS Phone: 206 395 -2033 8731 S 212TH STREET, KENT, WA 98031 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL PALLET RACKS. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N . Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * *k * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 118.76 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Size(in): .00 End Time: Fill: G o i Date : 1 - DTh I hereby certify that I have read and examined his permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Date: ? Z--1 ` Signature: Print Name: J.iktk T Q,!21\ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 1t 0s •. te flkt f Ci9.9 • , „ „ , I e 1; i:e d : .ce I # ....1(14 -94.19:1 • S it e d . ••••• • - ; klckk * 444 4444444 4 4* .41. ** * * k * A it 4 if 4 4 fr 4444 k k k *.k:k *44 k k'* k 444 : . • . •:p In On 1 es ••• a ppr' hn ineer : nti t I ri.w1h3 iu11dinitiiviSiOfl. : : . • , : , • , „tic' el •••• a 6 a a ti Ut..1t9i Ed1 t ion) .;.'4.iS • •.'a c a •:, • fhia s a •. -. D • II a 11 3% ;:k e r:n) s dr) • • . • • 'a; IabI at. the "017 „ 0 ! ":1 • r • r • io an.i aa • : aL Ie utl 1 tin 1 i p spet ta • 14! L Th 1 S.'.6 tic v„.' .'• 17 b e .COfl- •: rrued t'ci. a ria t, or an a i'rrov a I • ' 11 t',31% cn d trnr ord 1 riabn'e 07 che iur 1 s d 1 cr. 1 ort, , ..No per n).1 t D um1nQ ; to ove.»3uthor1ry ro violate or cancel tfle p? 1 iOfl oi h , • I) a :1 1 ::kta':•.. 1 • • •••• • . ; • i' . • ' • • i rb; IL P. - 4.4 •••• . • , ....**.....•■••••••••■•••••,-. Projeras en�an 5 S t oh 1s` 88 Value of Cin uct3 en , ill Site j) dvis1 AN000ti. Q t-- ' a1 it. TJ wI I ZA. T sj c a - D '—R O `t — 7 . 5iyo/ eittptipti Building Square Feet: L7 /7Z� existing Ph S: 4s3' )x.00 St ress( - - _ Atm_ 6E. Wtx., GJA Cit i t e ra i Fa x j j s • Li s -.14 (. 0s c rag. i 5 �. SyS�s Pl i 3 -31S -2.03.5 S gt fr s:�.,. Ufa �.. �1�'�"� 1� 4.144 t to I l Fax 3 3 S'"43 1 0 Architect: Phone: Street Address: City State /Zip: Fax #: Eneez:ooloot evodi; ocea n; #041 Pho ir„ t 14$ ., ��iu S N , I) /1 " filial 5 f 0 e f o 5 - �s t g: it J oQ— Life 7s3(4 P . 3 s 1.0 3 3 ContWer f im cer l� Su 1 St t� e s....4.4.. I a �' K Wm C. te/ l 1. ,4 15 , 3.. 31S...0 /o Description of work to be done: Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? [71 yes ❑ no Existing fire protection features: %sprinklers CI automatic fire alarm CI none ❑ other (specify) Building Square Feet: L7 /7Z� existing t Area of Construction: (sq. ft.) 4 10 1 30 sCv ic T" Will there be storage of flammable /combustible hazardous material in the building? ❑ yes a no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Da_ _te, pplion pt6d: end: Date ' on expires: Apt c "del Taken by: (initials) — t i (/ cppl l t1j CITY OF TUWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct Cl Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous CTPERMIT.DOC 1/29/97 FOR STAFF USE ONLY Pr ct Number: Permit Number: i c.)C 1 c/a Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST. FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE.FOLLO WING:. (Addltlonal. reviews may be determined by the Public Works Department) ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107,4 of the Uniform Building Code (current edition). No application shall be extended more than once. PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AU T R/ZED AGENT: Signature: ►'yam ti , e- 1 .r {� Date: -7) — / (( Print name: i `� _ u�l v�v1 �, e ,...) ...ST- Ph � Fax tt :. 3 S X033 _ - / ()< 375 Address (6 \ . olDA- a ( a -k City /State /Zip �/ � �b°31 ALL COMMERCIAUMULTI -FA, Y TENANT IMPROVEMENT /ALT ATION PERMIT APPLICATIONS MUS1 BE SUBMITTED WITH THE FOLL ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN )> BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which Include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) • 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ M Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 3 7 1, k:F:t•ie.k.i:'r:k:l:Fk k* a:h:kki: k .FA F.1*:1 ?t #:4th *:1 h:F:Fk�: *k. ?c:F:k :t k :lk:kka* :F.1:kk:1:F:h:k. i l ? r' t1i: t ir4cu� r 11)=1,::014....- _ t'i t.!.0; :m !• 1 • : F. 1,*•• k:i'k.4•k•k:i:Fh :k:lkcl .r kh:F'•t:k:lAnle 4k k4 F*: +'A* *.14k*:1•4 thrlf01 1 ,l utibti U l iHrcunt,. , O? 2 %,': {;a !. s: .: m 0 ii e t h o f1.:... t l l lr`i~ { f; ci 1� «.0 i o n : l� ra S Y Or P STORAGE:. .0 n •i t 1' L H • rvrt: i'L "PLRI' i'FULLUPI1iitd1 PLitMtr I r cH I. Now 35230A-9 :} } tr i4dilr ~� � i 17 0 4NIVER Pr •Ia rotal • i eeE,, 110.76 1'Ii f,S l /Oie.Ctl i2.1 5: :1 CALL r IJ.8 7.6 IIi.1lancn; • X00 d v* •k *•A*•kvF•k*h *;1:F•F,:1 *A it rot as ** .*A•:1iA kk * i. k�c•h •h4:t *:' :1•k**k **•k I ?esrnri r t i•'ar1.... Arno:int BUILDING UNIiES ••�': f3 13U ELl3XI4I) ::l.IRI:WI4UO 4.3Q 14cc aunt CodIi QQQ/'322. J.OQ 0'00/34. 904 5377 07 /28 9 1717 TOTAL 73.75 ,R ' #•'M7.§;'t r ' sy `, '. ti4r .tt ,4 i*1***• k* kot.* o,tt****. 4**, 1** * * *�+.A11** * * * *A ** * * ,! * *.4 *S'* � * Cl TY. OF' •T.u.KwxLH, wn ..%. 'TRANSMIT * *, * * * * ** * * *4 * *. * * * * * * ** * A*f* * * *F *,t ****,4*.A *4 *,l** TRA Number: 89800099 Amount: 4544:07/07/99-16:20. Payment Methlod: CHECK Notation: EA5Y...:IIP SHELVING .Init: Till Permit .No D99.0228 Type: DEVPERM DEVELOPMENT PERM/1 Parcel No 352304-909? Site Address: 1177 ANDOVER PK W Total Fees: Total ALL Pmts: Balance: This Payment 45.01 *. 4 ******** 4 **4*+ 4**** A+ l **** *,+ b ******* *& A * *A•A *:l *4 * *** ** *,t * * * #•A• *?*** Account Code Description Amount 000/345.830 PLAN CHECK - NOh1REa 45.01 „7G 45.01 73.7 : 4765 07/0£3 9717 TOTAL... 45 01 Project ..4(t t n a -1(113 y�; f� ion: \e1`1 a b 8- e- ( kg Special instr . I Date w ted: ri i a.m. P.m. Requester: (\ t +_ Phone: �, 1 � , ,� (( 1 � ( INSPECTION RECORD' Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, W 98188 Approved per applicable codes. roict oaag PERMIT NO. (206)431 -3670 Corrections required prior to approval. $47.1 i SPE TION FEE RE RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. OMMENTS: Receipt No: Date: :' INSPECTION. NO. CITY OF.TUKWILA BUILDING DIVISION '6300 Southcenter Blvd, #100, Tukwila, WA 98188 r7P7 otfS P4 TYp e �Hti Special instructions: Date called: Dat anted: A 4 6 t a.m. Regyester: Phone: Approved per applicable codes. 1 PECTION RECOR Retain a copy with perm (206)431 - Corrections required prior to approval. COMMENTS: Inspector- 4 . _ EI $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Pr I ct: nA ;' ' 5 / Typnf y en:W i / 1,7/Vi / , / to called: Vgl ial instructions: jr'�'_1 ... Date wanted: � 7���/ / / p.m. Requester: '� //t ; Q 2 Phon v53 3 95 ,33 PERMIT NO. INSPECTION CITY OF TUKWILA BUILDING DIVISION ;:6300 Southcenter Blvd ; - #100, Tukwila; WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: A,dtl-f -S fix.... $p . PAJAC D ;, $ 7.00 REINSPECTION FEE REQUIRED. Prior to inspection, ection,,, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project Name Address FINALAPP.FRM City of Tukwila Fire Department i 1WVe S[i; (' e p 1• , Retain current inspection schedule 4/1-C.../<s Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Approved without correction notice Approved with correction notice issued Permit .N John W. Rants, Mayor Thomas P. Keefe, Fire Suite # po (el° Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 floor plan file copy J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB SHEET NO. 99 I l , 2 0 OF CALCULATED BY -A6(- ) DATE 1/99 CHECKED BY DATE SCALE JOB NAME PIONEER SHIP SUPPLY SCOPE OF WORK DESIGN PARAMETERS Determine the anchorage and baseplate requirements of the storage racking subject to Seismic Zone III loadings per the 1997 Uniform Building Code. All racking components have been designed by others and is beyond the scope of this analysis. CONCRETE SLAB THICKNESS - CONCRETE fc - ALLOWABLE SOIL BEARING PRESS. - STEEL PLATES (A36) Fy - RAWL-STUD EXPANSION ANCHORS OR EQUAL Seismic Analysis: 97 UBC 1630.2 Seismic Zone 3 V = (2.5 *Ca / R) *I *W Z= I= C, = R= (2.5 *Ca / R) *I= F, = p= C = (2.5 *C, /R) *I* r/F, = 0.15 (Adjusted Seismic Coef.) V = 0.15 W Pi = V * (Wi *Hi) /SUM(Wx *Hx) SEE SHEETS 2- 14 FOR MORE LOADING INFO. 5.0 inches 2500.0 psi 2000.0 psf 36.0 ksi 0.30 1.0 0.36 4.4 0.20 1.40 (Working Stress Reduction Factor) 1.0 (Redundancy/Reliability Factor) C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 SHEET NO OF CALCULATED BY -3S0 0 DATE 1 / 9 9 CHECKED BY DATE SCALE JOB INPUT DATA RACK TYPE 2 Level (Case- I V) DEPTH OF RACK = # OF SHELF LEVELS LEVEL # 1 2 WEIGHT, Wi 2.00 kips 2.00 kips CASE I - ALL LEVELS LOADED 3.00 FEET 2.0 # Wi Hi WxH Pi M (kips) (feet) (kip -ft) (kips) (kip -ft) 1 2.00 11.33 22.67 0.406 4.60 2 2.00 5.00 10.00 0.179 0.89 4.00 32.67 0.58 5.49 Mot = 1.15 *SUM (M) = 6.31 kip -ft Mres. = SUM(W) *D /2 6.00 kip -ft DOWNLOAD = (Mot + Mres.)/D = 4.10 kip UPLIFT = (Mot - Mres.) /D 0.10 kip HEIGHT, Hi 11.33 feet 5.00 feet C PRODUCT 207 • J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468-7626 FAX: (509) 468-7534 907) 7 0 JOB OF SHEET NO .3 CALCULATED BY 6C..v DATE 7 /9 CHECKED BY DATE SCALE Mot = Mres. = - ALL LEVELS LOADED EXCEPT BOTTOM Wi Hi W x H Pi M (kips) (feet) (kip-ft) (kips) (kip-ft) 2.00 11.33 22.67 0.292 3.31 5.00 1.15*SUM (M) = SUM(W)D/2 DOWNLOAD = (Mot + Mres.)/D = UPLIFT = (Mot-Mres.)/D 22.67 3.31 3.81 kip-ft 3.00 kip-ft 2.27 kip 0.27 kip C PRODUCT 207 V / .— - Lmax Ypi Lmax / / IX ti O J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 II. 20 JOB SHEET NO. CALCULATED BY .16 h DATE 7/ CHECKED BY DATE SCALE 4 / OF BASEPLATE CASE IV RACK TYPE: 2 -level MAX DOWNLOAD = MAX UPLIFT = COLUMN DIMENSIONS X= Y= PLATE DIMENSIONS X= y 4.10 kips SLAB ANALYSIS 0.27 kips 1.63 inches 3.00 inches 5.00 inches 8.00 inches SLAB THICKNESS = 5.0 inches F'c = 2500 psi SOIL BRG = 2000 psf Fy = 36 ksi Ft = 3.5'SQRT(F'c) 175.00 psi S = 50.00 in ^3 Ma = 729.17 #' SOIL BRG = 2666.67 psf M = 1 /2(SOIL)L ^2 Lmax = 8.87 inches SOIL Areq'd = 1.54 feet ^2 X slab = 22.75 inches Y slab = 25.75 inches SOIL A prov = 4.07 feet ^2 SLAB OK BASEPLATE ANALYSIS TRY pLw /t= S= Fb= MpL = MpL = 1/2'fp'l ^2 ApL =x' y le max = a prov. = b prov. = 0.375 inches 0.023 in ^3 36.0 ksi 0.844 kip" 5.279 inches 1.688 inches 2.500 inches a eff, = 1.688 inches b eff. = 2.500 inches 1 eff = 2.500 inches ApL eff. = 40.000 inches ^2 fp = P/A = 0.103 ksi MpL = ,. 0.321 _ kip". ___- t req'd = !, 0.231 inches ) BASEPLATE OK .__.._. - _..._ - -- CASE IV SLAB ANALYSIS BASEPLATE ANALYSIS C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB ! /C /, 2 0 SHEET NO. 6 OF CALCULATED BY DATE 7/91 CHECKED BY DATE SCALE RACK ELEVATION (CASE I) C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB SHEET NO. OF CALCULATED BY J GG DATE 7 /9 CHECKED BY DATE SCALE C PRODUCT 207 • C� J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468-7626 FAX: (509) 468 -7534 4 +5' -4" A:F.F 1/2" =V -0" JOB SHEET NO 2000# 2000 # qL /Irzo 7 OF CALCULATED BY 166 DATE 7 CHECKED BY DATE SCALE 1 RACK ELEVATION (CASE III) C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB . f zo SHEET NO. OF �j b CALCULATED BY J GC7 DATE ` y / / / CHECKED BY DATE SCALE C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468-7626 FAX: (509) 468-7534 JOB SHEET NO OF CALCULATED BY ,OS DATE CHECKED BY DATE SCALE C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB , ... .; 7/ • ZO /0 OF 1/9 9 BY _366 DATE CHECKED BY DATE SCALE SHEET N0. INPUT DATA RACK TYPE 3- Level C Cctse DEPTH OF RACK = # OF SHELF LEVELS LEVEL # 1 2 3 WEIGHT, Wi 2.00 kips 2.00 kips 2.00 kips CASE I - ALL LEVELS LOADED 3.00 FEET 3.0 HEIGHT, Hi 11.33 feet 8.00 feet 4.42 feet # Wi Hi WxH Pi M (kips) (feet) (kip -ft) (kips) (kip -ft) 1 2.00 11.33 22.67 0.418 4.74 2 2.00 8.00 16.00 0.295 2.36 3 2.00 4.42 8.83 0.163 0.72 6.00 47.50 0.88 7.82 Mot = 1.15 *SUM (M) = 9.00 kip -ft Mres. = SUM(W) *D /2 9.00 kip -ft DOWNLOAD = (Mot + Mres.)/D = 6.00 kip 0.00 kip UPLIFT = (Mot- Mres.)/D C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 SHEET NO / I OF CALCULATED BY _1661 7/ DATE ?? CHECKED BY DATE SCALE CASE II Mot = Mres. _ - ALL LEVELS LOADED EXCEPT BOTTOM 1.15'SUM (M) = SUM(W)''D /2 DOWNLOAD = (Mot + Mres.)/D = UPLIFT = (Mot - Mres.)/D Wi Hi WxH Pi (kips) (feet) (kip-ft) (kips) 2.00 11.33 22.67 0.343 2.00 8.00 16.00 0.242 4.42 38.67 6.69 kip -ft 6.00 kip -ft 4.23 kip 0.23 kip C PRODUCT 207 4 L / 7 , ._.__ Lmax Ypi Lmax / / / IX J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB . ZO SHEET NO OF CALCULATED BY — 166 DATE -// Q CHECKED BY DATE SCALE BASEPLATE CASE IV RACK TYPE: 3 - level MAX DOWNLOAD = 6.00 kips MAX UPLIFT = 0.27 kips COLUMN DIMENSIONS X= Y= PLATE DIMENSIONS x = 5.00 inches 8.00 inches SLAB THICKNESS = — 5:OTh es Fc = SOIL BRG = Fy = SLAB ANALYSIS BASEPLATE ANALYSIS TRY pLw /t= S= Fb= MpL MpL = 1/2 *fp +i^2 ApL =x *y le max = a prov. = b prov. = a eff. = beff.= l eff = ApL eff. _ fp = P/A = MpL t req'd = BASEPLATE OK 1.63 inches 3.00 inches 2500 psi 2000 psf 36 ksi Ft = 3.5 *SQRT(F'c) 175.00 psi S = 50.00 in ^3 Ma = 729.17 #' SOIL BRG = 2666.67 psf M = 1 /2(SOIL)L ^2 Lmax = 8.87 inches SOIL Areq'd = 2.25 feetA2 X slab = 22.75 inches Y slab = 25.75 inches SOIL A prov = 4.07 feetA2 SLAB OK 0.375 inches 0.023 in ^3 36.0 ksi 0.844 kip" 3.896 inches 1.688 inches 2.500 inches 1.688 inches 2.500 inches 2.500 inches 40.000 inches ^2 0.150 ksi 0.279 Inches Inches CASE I V SLAB ANALYSIS BASEPLATE ANALYSIS C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB 99t: , , Zo Y l3 OF SHEET NO CALCULATED BY J 667 DATE 7/ CHECKED BY DATE SCALE C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468 -7534 JOB ! ek_:' /. 10 SHEET NO, 1 OF CALCULATED BY -16 C7► DATE 7/9 ? CHECKED BY DATE SCALE C PRODUCT 207 J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468-7534 it) G 1/2 " =1 BASEPLATE DETAIL 1/8 STEEL POST BY OTHERS. PL 3/8" W/ (2) 1 /2 "0 RAWL STUD EXP. ANCH. W/ 3" EMBED. (SPECIAL INSP. NOT REQ'D.) CITY Of WO APPROVED JUL 23 1999 AS NOTED JOB .. 7/, SHEET NO ` M/ / /� CALCULATED BY 16ST DATE ( CHECKED BY DATE SCALE IS OF C PRODUCT 207 2. 1/2" 3 „ 2 1/2" 1 U / TYP. I 03 A Ow 1 i � J.R. BONNETT ENGINEERING 9306 North Newport Highway SPOKANE, WA 99218 TEL: (509) 468 -7626 FAX: (509) 468-7534 it) G 1/2 " =1 BASEPLATE DETAIL 1/8 STEEL POST BY OTHERS. PL 3/8" W/ (2) 1 /2 "0 RAWL STUD EXP. ANCH. W/ 3" EMBED. (SPECIAL INSP. NOT REQ'D.) CITY Of WO APPROVED JUL 23 1999 AS NOTED JOB .. 7/, SHEET NO ` M/ / /� CALCULATED BY 16ST DATE ( CHECKED BY DATE SCALE IS OF C PRODUCT 207 appendix ,„ ANCHOR DIAMETER (Inches) EMBEDMENT DEPTH (Inches) INSTALLATION TORQUE (Ft. Lbs.) r. ■ 2000 psI r' c 4000 M r' a 6000 psi Tension MIICaut SP &upsetIon° Tension 1/4 Tension 850 With Sp. hap! Without Sp.Insp? Sheer With Sp. Insp! Without Sp.lnsp? . Sheer Sp. Insp.' Without Sp. Insp.s Shear 1 /4 1 2250 1125 8 420 210 365 570 285 520 570 285 . 520 1 /1 1 •: , 8 530 265 415 645 • 325 520 640 320 520 1 4 2 8 680 340 480 720 360 ' 520 765 380 '520 3 /a 13/4 28 890 445 960 1030 515 1295 ' 1040 520 1450 3 4 2 28 975 490 1065 1075 540 1355 1100 530 1480 3 4 3 • 28 1200 600 1350 1200 ' 600 1510 . 1335 665 1560 1 /2 2 60 1630 815 1600 1655 830 1735 1655 830 1745 1 /2 3 60 1785 890 1655 2015 1005 1800 2015 1005 1825 1 /2 4 ' 60 • 1985 ' 995 1725 2485 ' 1245 1885. • 2485 1245. 1930 s /a 2 90 1910 955 2215 2090 1045 2215 2100 1050 2525 s /a 4 90 2345 1170 2305 2535 1270 2420 2890 1445 2595 5 /1 5 90 2755 1375 2375 2890 1445. 2585 3525 1765 2566 3 /4 3 175 2685 1345 3665 2685 1345 3665 3880 1940 3815 3 /4 5 175 3715 1855 3945 3925 - 1960 4280 4845 2425 4510 3 /4 6 • •175 4345 2175 4115 4685 2345 4655 5400 2720 4940 7 /11 3 250 3085 1540 — 3955 1980 ' — 4820 2410 — 7 /a 4 250 3575 1790 — 4405 2205 — 5250 2625 — 7 /5 5 250 4560 2280 — 5305 2655 — 6110 3055 — 1 43/4 300 3470 1735 — 5000 2500 — 6845 3420 — 1 5 300 4565 2285 — 5680 2840 — 7475 3755 — 1 6 300 5845 • 2920 — 6365 3180 — '7800 3900 — 1 53/4 450 5P60 2530 — 6830 3415 — 1 8750 4375 — 1 7 450 5060 2530 — 7000 3500 — 9050 4525 — ANCHOR (Inches) HOLE SIZE (Inclee) EMBEDMENT DEPTH (Inches) r,. x000 pet limbo Sheer Muth SPeclal Inspection' MIICaut SP &upsetIon° 1/4 1/4 1 850 425 455 3 /a I/2 1 1600 800 1055 1/ 3/s 23/4 2250 1125 1660 3 /1 3 /1 3 2615 1310 3100 3 /4 I 3 3480 1740 4400 Page 4 of 10 TABLE NO..II —RAWL -STUD ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (Pounds) 1 The tabulated shear and tensile values are for anchors installed in stone - aggregate concrete having the designs ed ultimate compressive strength at the time of installation. 2 The tabulated values are for anchors installed a minimum of 12 diameters on center and a minimum edge distance of six diameters for 100 percent anchor efficiency. Spacing and edge distance may be reduced to six - diameter spacing and three diameter edge distance, provided the values are reduced 50 percent. Linear interpolation may be used for intermediate spacings and edge margins. ) These tension values are applicable only when the anchors are installed without special inspection as set forth in Section 306 of the code. 'These tension values are applicable when the anchors are installed with special inspection as set forth in Section 306 of the code. 5 The allowable loads may not be increased for duration of loading such as for wind or seismic loads. TABLE NO. 111 —BAWL STEEL DROP -IN ALLOWABLE SHEAR AND TENSION VALUES (Pounds) The tabulated shear and tensile values are for anchors installed in stone- aggregate concrete having the designated ultimate compressive strength at the time of insta lation. 2 The tabulated values are for anchors installed a minimum of 12 diameters on center and a minimum edge distance of six diameters for 100 percent anchor efficiency. Spacing and edge distance may be reduced to six - diameter spacing and throe-diameter edge distance, provided the values are reduced 50 percent. Linear interpolation may be used for interme- diate spacings and edge margins. 3 These tension values are applicable only when the anchors are installed without special in- spection as set forth in Section 306 of the code. 4 These tension values are applicable when the anchors are installed with special inspection as set forth in Section 306 of the code. Slite allowable loads may not be increased for duration of loading such as for wind or seis- mic loads. t '11te Drop -In anchor must be completely embedded within the concrete. r CHAP. 16, DIV. IV 1630.1.2 1630.3.2 and strength of elements, which are significant to the distribution of forces, and shall represent the spatial distribution of the mass and stiffness of the structure. In addition, the model shall comply with the following: 1. Stiffness properties of reinforced concrete and masonry ele- ments shall consider the effects of cracked sections. 2. For steel moment frame systems, the contribution of panel zone deformations to overall story drift shall be included. 1630.13 PA effects. The resulting member forces and moments and the story drifts induced by PA effects shall be considered in the evaluation of overall structural frame stability and shall be evaluated using the forces producing the displacements of As. PA need not be considered when the ratio of secondary moment to pri- mary moment does not exceed 0.10; the ratio may be evaluated for any story as the product of the total dead, floor live and snow load, as required in Section 1612, above the story times the seismic drift in that story divided by the product of the seismic shear in that story times the height of that story. In Seismic Zones 3 and 4, PA need not be considered when the story drift ratio does not exceed 0.02/R. 1630.2 Static Force Procedure. 1630.2.1 Design base shear. The total design base shear in a given direction shall be determined from the following formula: V = R = T W (30 The total design base shear need not exceed the following: V = 2 R ' f w (30 The total design base shear shall not be less than the following: V = 0.11 C, C W (30 -6) In addition, for Seismic Zone 4, the total base shear shall also not be less than the following: V — 0.8 ZN,. I lV (30 1630.2.2 Structure period. The value of T shall be determined from one of the following methods: 1. Method A: For all buildings, the value T may be approxi- mated from the following formula: T = C, (h,) (3(1-8) WHERE: C = 0.035 (0.0853) for steel moment - resisting frames. C = 0.030 (0.0731) for reinforced concrete moment- resist- ing frames and eccentrically braced frames. Cr = 0.020 (0.0488) for all other buildings. Alternatively, the value of C for structures with concrete or ma- sonry shear walls may be taken as 0.1/J (For SI: 0.0743/ g for A in m The value of shall be determined from the following for- mula: A = EA, [0.2 + (Del h.)2] (30 - 9) The value of D /b„ used in Formula (30 -9) shall not exceed 0.9. 2 -14 T = 1997 UNIFORM BUILDING CODE 2. Method B: The fundamental period T may be calculated us- ing the structural properties and deformational characteristics of the resisting elements in a properly substantiated analysis. The analysis shall be in accordance with the requirements of Section 1630.1.2. The value of T from Method B shall not exceed a value 30 percent greater than the value of T obtained from Method A in Seismic Zone 4, and 40 percent in Seismic Zones 1, 2 and 3. The fundamental period T may be computed by using the fol- lowing formula: w 61 z s (g fr 6 (30 -10) r -r The values ofj represent any lateral force distributed approxi- mately in accordance with the principles of Formulas (30 - 13), (30 -14) and (30 -15) or any other rational distribution. The elastic deflections, , shall be calculated using the applied lateral forces, j. 1630.23 Simplified design base shear. 1630.2.3.1 General. Structures conforming to the requirements of Section 1629.8.2 may be designed using this procedure. 1630.23.2 Base shear. The total design base shear in a given direction shall be determined from the following formula: V = 3.0 Ca W (30 -11) where the value of C shall be based on Table 16-Q for the soil pro- file type. When the soil properties are not known in sufficient detail to determine the soil profile type, Type SD, shall be used in Seismic Zones 3 and 4, and Type SE shall be used in Seismic Zones 1, 2A and 213. In Seismic Zone 4, the Near -Source Factor, N need not be greater than 1.3 if none of the following structural irregular- ities are present: Type 1, 4 or 5 of Table 16 -L, or Type 1 or 4 of Table *6-M. 1630.233 Vertical distribution. The forces at each level shall be calculated using the following formula: 3. (30 -12) where the value of Ca shall be determined in Section 1630.2.3.2. 1630.2.3.4 Applicability. Sections 1630.1.2, 1630.1.3, 1630.2.1, 1630.2.2, 1630.5, 1630.9, 1630.10 and 1631 shall not apply when using the simplified procedure. EXCEPTION: For buildings with relatively flexible structural systems, the building official may require consideration of PD effects and drift in accordance with Sections 1630.1.3,1630.9 and 1630.10. e shall be prepared using design seismic forces from Section 1630.2.3.2. Where used, Au shall be taken equal to 0.01 times the story height of all stories. In Section 1633.2.9, Formula (33 -1) shall read F = 3.0 R C ' w and need not exceed 1.0 C w but shall not be less than 0.5 C w . R and (2 shall be taken from Table 16 - 16303 Determination of Seismic Factors. 1630.3.1 Determination of 6?,. For specific elements of the structure, as specifically identified in this code, the minimum design strength shall be the product of the seismic force over - strength factor (2,, and the design seismic forces set forth in Sec- tion 1630. For both Allowable Stress Design and Strength Design, the Seismic Force Overstrength Factor, f2,, shall be taken from Table 16 -N. 1630.3.2 Determination of R. The notation R shall be taken from Table 16 -N. 1997 UNIFORM BUILDING CODE SECTION 1636 — SITE CATEGORIZATION PROCEDURE 1636.1 Scope. This division describes the procedure for deter- mining Soil Profile Types SA through SF in accordance with Table 16 -J. 1636.2 Definitions. Soil profile types are defined as follows: Hard rock with measured shear wave velocity, V 5,000 ft. /sec. (1500 m/s). Rock with 2,500 ft./sec. < V, 5 5,000 ft./sec. (760 m/s < V, 5 1500 m/s). Sc Very dense soil and soft rock with 1,200 ft. /sec. < V, 5 2,500 ft. /sec. (360 m/s V, 5 760 m/s) or with either 11> 50 or Y z 2,000 psf (100 kPa). SD Stiff soil with 600 ft./sec. s V, 5 1,200 ft. /sec. (180 m/s 5 V, 5 360 m/s) or with 15 5 N s 50 or 1,000 psf s Y 5 2,000 psf (50 kPa s 3%, 5 100 kPa). SE A soil profile with V,< 600 ft. /sec. (180 m/s) or any pro- file with more than 10 ft. (3048 mm) of soft clay defined as soil with PI > 20, w,,,, z 40 percent and s < 500 psf (25 kPa). SF Soils requiring site - specific evaluation: 1. Soils vulnerable to potential failure or collapse under seis- mic loading such as liquefiable soils, quick and highly sensitive clays, collapsible weakly cemented soils. • 2. Feats and/or highly organic clays [H > 10 ft. (3048 mm) of peat and/or highly organic clay where H = thickness of soil]. 3. Very high plasticity clays [11 > 25 ft. (7620 mm) with PI > 75]. 4. Very thick soft/medium stiff clays [11 > 120 ft. (36 580 mm)]. SA SB Division V —SOIL PROFILE TYPES EXCEPTION: When the soil properties axe not known In sufficient detail to determine the soil profile type, Type SD shall be used. Soil Pro - '"liie Type SE need not be assumed unless the building official deter- mines that Soil Profile Type SE maybe present at the site or in the event that Type SE Is established by geotechnical data. The cn eria set fo ttt ' e ' finrtion or . , Profile Type SF requiring site - specific evaluation shall be considered. If the site corresponds to this criteria, the site shall be classified as Soil Pro- file Type SF and a site - specific evaluation shall be conducted. 1636.2.1 V„ Average shear wave velocity. V, shall be deter- mined in accordance with the following formula: V, = Ed t-1 " d "s WIIERE: d; = thickness of Layer i in feet (m). vst = shear wave velocity in Layer i in ft. /sec. (rn/sec). 1636.2.2 N, average field standard penetration resistance and Ncn, avera g standard penetration resistance for cohesionless soil layers. N and Ncyr shall be determined in accordance with the following formula: and N E dt 1 -1 " d !V1 r -1 d, Nee = E N 1 -1 — CHAP. 16, DIV. V 1636 1636.2.6 (36 -2) (36 -3) WHERE: d; = thickness of Layer i in feet (mm). d, = the total thickness of cohesionless soil layers in the top 100 feet (30 480 mm). Nr = the standard penetration resistance of soil layer in accordance with approved nationally recognized stand- ards. 1636.2.3 8„ Average undrained shear strength. 3', shall be determined in accordance with the following formula: d� A s,, r -1 (36-4) WHERE: 4 = the total thickness (100 - d,) of cohesive soil layers in the top 100 feet (30 480 mm). S,,; = the undrained shear strength in accordance with approved nationally recognized standards, not to exceed 5,000 psf (250 kPa). 1636.2.4. Soft day profile, SE. The existence of a total thickness of soft tlay greater than 10 feet (3048 mm) shall be investigated where a soft clay layer is defined by s, < 500 psf (24 kPa), 40 percent and P1 > 20. If these criteria are met, the site shall be classified as Soil Profile Type SE. 1636.25 Soil profiles Sc, SD and SE. Sites with Soil Profile Types So SD and SE shall be classified by using one of the follow- ing three methods with V, Nand 3, computed in all cases as speci- fied in Section 1636.2. 1. V, for the top 100 feet (30 480 mm) (V, method). 2. N for the top 100 feet (30 480 mm) (A7 method). 3. Ncif for cohesionless soil layers (PI < 20) in the top 100 feet (30 480 mm) and average Y. for cohesive soil layers (PI > 20) in the top 100 feet (30 480 mm) (S method). 1636.2.6 Rock profiles, SA and SR. The shear wave velocity for rock, Soil Profile Type SB, shall be either measured on site or esti- (36-1) mated by a geotechnical engineer, engineering geologist or seismologist for competent rock with moderate fracturing and weathering. Softer and more highly fractured and weathered rock shall either be measured on site for shear wave velocity or classi- fied as Soil Profile Type Sc. The hard rock, Soil Profile Type SA, category shall be supported by shear wave velocity measurement either on site or on profiles of the same rock type in the same formation with an equal or greater degree of weathering and fracturing. Where hard rock con- ditions are known to be continuous to a depth of 100 feet (30 480 mm), surficial shear wave velocity measurements may be extrap- olated to assess V,. The rock categories, Soil Profile Types SA and 2 -23 TABLE 164 =SEISMIC COEFFICIENT C, SEISMIC ZONE FACTOR, Z sOLPROf,.ETYPE Z ■0075 ZuatS Z. 0.2 Zr' Z. OA 54 0.06 0.12 0.16 0.24 0.32M, SB 0.Q8 0.15 0.20 0.30 0.40N, Sc 0.09 0.18 0.24 0.33 0.40N, S0 0.12' • 0.22 0.28 N, 0.44 0.19 0.30; 0.34 0.36 0.36N, SF See Footnote 1 1 1997 UNIFORM BUILDING C' Devices acting as bumpers to stop moving equipment shall be considered in the design. Forces described in this section need not act concurrently with those described in Sections 2228.3.2 and 2228.5.1. 2228.4 Wind Loads. Outdoor racks exposed to wind shall be de- signed for the wind loads prescribed by Chapter 16 acting on the horizontal projection of rack plus contents. For stability, consider- ation shall be given to loading conditions that produce large wind forces combined with small stabilizing gravity forces, such as racks fully loaded, but with unit loads of much smaller weight than the maximum posted unit load. Forces described in Sections 2228.3.2 and 2228.5.1 need not act concurrently with wind loads. Forces described in Section 2228.3.3 shall act concurrently with wind forces for design pur- poses. 2228.5 Earthquake Loads. 2228.5.1 General. Steel storage racks which are not connected to buildings or other structures shall be designed to resist seismic forces in conformance with this standard. 2228.5.2 Minimum earthquake forces. The total minimum lateral force at strength design levels shall be determined in ac- cordance with Section 1630.2.1: r racks or portions thereof where lateral stability is dependent on diagonal or x- bracing. Connections for bracing members shall be capable of developing the re- quired strength of the members. R = 5.6 for racks where the lateral stability is wholly depen- dent on moment - resisting frame action. W = weight of rack stricture plus contents. Where a number of storage rack units are interconnected so there are a minimum of four columns in any direction on each col- umn line designed to resist horizontal forces, W may be equal to the total dead load plus 50 percent of the rack - rated capacity. In Seismic Zones 3 and 4, wholesale and retail areas, the 50 percent may only be used when com- bined with C,JRT taken equal to 0.70C in Formula (30-4) and with 2.5/R taken equal to 0.70 in Formula (30 -5). lbtal seismic force shall be assumed to act nonconcurrently in the direction of each of the main axes of the rack. For racks having more than two storage levels, the total lateral force, V shall be dis- tributed over the height of the rack in accordance with Ft = A E Wihi i -r in which F is the lateral force applied at Level i; IN is the portion of the total weight; W, which is assigned to Level i; h is the height CHAP. 22, DIV. x 2228.3.3 2229.3 of Level i above the base of the rack; and n is the total number of storage levels. The lateral force, V, shall be distributed in propor- tion to the total weight, W. Other R values may be considered based on submission of substantiating data. 2228.6 Storage Racks in Buildings. Storage racks located in buildings at levels above the ground level, rack buildings or racks that depend on attachments to buildings or other structures at other than the floor level for their lateral stability, shall be designed to resist earthquake forces that consider the responses of the building and storage rack to earthquake ground motions as specified in Chapter 16, Division III. 2228.7 Other Considerations. 2228.7.1 Overturning. In determining overturning moments, the total weight shall be assumed to act at a height equal to 1.15 times the distance from the floor to the actual center of gravity of all the horizontal forces. Equal safety against an overturning moment shall be provided when only the top level of the rack is loaded, in which case it is to be assumed that the force acts through the center of gravity of the top load. 2228.7.2 Torsional forces. Torsional forces shall be considered based on the critical combination of loaded and unloaded storage spaces. 2228.7.3 Concurrent forces. Forces described in Sections 2228.3.2, 2228.3.3 and 2228.4 need not be assumed to act concur- rently with earthquake loads. SECTION 2229 — SPECIAL RACK DESIGN PROVISIONS 2229.1 Stability of Truss- braced Upright Frames. The maxi- mum allowable compression stress in the posts of truss- braced up- right frames shall be determined from Divisions I and IV. 2229.2 Overturning and Height -to -depth Ratio. Overturning shall be based on the critical combination of vertical and horizon- tal bads. Stabilizing forces provided by anchor bolts to the floor shall not be considered to resist overturning unless the anchors are specifically designed and installed to resist the uplift forces. Un- less all columns are so anchored, the minimum ratio between righting moment and overturning moment shall be 1.5. Sections 2228.4 and 2228.7 shall be considered iri the design. The height -to -depth ratio of a storage rack shall not exceed 6 to 1 measuring to the top of the topmost load unless the rack is an- chored or braced externally. 2229.3 Connections to Buildings. Connections of racks to buildings, if any, shall be designed and installed to prevent reac- tions or displacements of the buildings or racks from damaging one another. Section 2228.5 shall be considered. 2 -271 ja R • - 1,30NNETT ENGINLERING • CIVIL & STRUCTURAL ENGINEERING/CONSULTING 9306 N. NEWPORT HIGHWAY SPOKANE, WA. 99218 (509) 468-7626 July 6, 1999 Matt Prevost •Easy-Up Storage Systems 8731 S 212th Kent, WA 98031 • RE: Seismic Anchoring for Storage Racking for: Pioneer Ship Supply 1177 Andover Pk. W. Bldg. B Tukwila, WA 98188 (JRBE Job # 99171.20) • Dear Mr. Prevost, Review of the information relating to the storage racking at the above location revealed two basic loading conditions with seven geometries. The various loading conditions are illustrated within the attached seismic analysis. Based on the information you provided, calculations have been performed for the rack types and loading conditions with respect to overturning due to lateral seismic forces. It has been determined that the racking will require baseplates and anchoring per sheet 15 of the attached seismic analysis. This method of anchoring will accept a resistive force deemed adequate per the 1997 Uniform Building Code requirements for seismic loading with respect to overturning. Please contact us if you have any question. Sincerely, J.R. Bonnett Engineering Jim Gradwohl, P.E. CITY JUL 0 7 1999 PERMIT CENTER D61411.0228 -:r. � t+ �.' ,' ;r . •N�yt 'r >; •Nit,*"' ro tt . �','� . %' �"ft rte i.'• .t.,y,• } r a r 1 ".w`iwr n, - :: kl"'C�✓s.'ii�ail' 1,. {,�i?:�.u�zt��' +"�.rxo :r.4di}kh�!t V:- fJ: ✓�i�:"'SwkiS�t: }L .l,E l r.1 , . cd�� r.., ��a'i�n:Ed, r. �.�sU. i;d'+y E: - - ►_ PROJECT:: NAME:. ~ PIONEER SHIP SUPPLY XX` Original: Plan Submittal: • Response to Incomplete Letter Response to Correction Letter.,# Revision.# . :After Permit 'Is Issued ITY NUMBER D99 -0228 DA DEPARTMENTS: Build'i`ng`Division file 1 -8-Rq Public Works C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete kl Incomplete Not Applicable n Comments: APPROVALS OR CORRECTIONS: (ten days) Approved U'RROUTE.DOC 5/99 Prt Ccorci PLAN REVIEW/ROUTING SLIP NU Fire Prevention El Structural Approved with Conditions Planning Division Permit Coordinator DUE DATE: 7 -8-99 TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required DUE DATE 8 -5-99 n REVIEWER'S INITIALS: DATE: Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved 1111 Approved with Conditions El Not Approved (attach comments) El REVIEWER'S INITIALS: DATE: Dear Sir: Fire Department Review Control #D99 -0228 510 July 13, 1999 Re: Pioneer Ship Supply - 1177 Andover Park West Bldg. B Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) 2. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) 3. High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) 4. Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) 5. Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 Page number determined by the Tukwila Fire Prevention Bureau. (NFPA 231C, 3 -2.3) 6. Smoke venting and curtain boards required by Table 81 -A of the 1997 edition of the Uniform Fire Code, shall be provided and installed per section 8102.7 and Table 81 -B of the 1997 edition of the Uniform Fire Code. 7. Racks designed for high -piled storage must comply with section 2207 of The Uniform Building Code. Please contact The Tukwila Building Department for details pertaining to design and installation standards. 8. Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 231c 4 -3.1) 9. A permit is required to use any building or portion thereof exceeding 500 square feet for high -piled combustible storage. (UFC 105.8 -h.3, article 81) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, City of Tukwila Fire Department 6s, The Tukwila Fire Prevention Bureau cc: T.F.D. file dm John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575 4439 106) 395-2033 FAX (206) 395-0108 300-426-9234