Loading...
HomeMy WebLinkAboutPermit D99-0263 - Southcenter Mall - Godiva - Kiosk• • • , • S•k'f'.. i•••;?:•.•,:-•<.•1' • • , %•17• 0 :4••1 41'5 ■17,A4.1..;;;;,:,,,.,•,;4„..„,„;••,,,, • t • • • • • • • . • • • • • • • .• • I „ • • • „ • • ••: • , ' • .••• • .• • • ..• . , • ' • , Sout center Mall Godiva Chocolates City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9004 Address: 309 SOUTHCENTER MALL Suite No: Location: Category: ARET Type: DEVPERM Zoning: Const Type: V -N Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Contractor License No: WILCOC *19400 DEVELOPMENT PERMIT Permit No: Status: Issued: Expires: (206) 431 -3670 D99 -0263 ISSUED 08/24/1999 02/20/2000 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERED /AFA East: .0 West: .0 Streams: OCCUPANT GODIVA CHOCOLATES 309 SOUTHCENTER MALL, TUKWILA,WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT DENNIS MORRISY Phone: 440 -808 -7554 25425 CENTER RIDGE ROAD, CLEVELAND, OHIO 44145 CONTRACTOR WILCOX CONSTRUCTION INC Phone: 425 774 -4185 123 4TH AVE N, EDMONDS, WA 98020 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: PREPARATION FOR MALL KIOSK AND STORAGE ROOM FOR GODIVA CHOCOLATES. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 10,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 303.56 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this developmen per t. Signatur_ / _ Date: 6 Print N y .711 0.4-e SE Date: ( V11 ( 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. • 'At '1. • I T r;)F. TUi <.W1 LA: L Per•mi t. No D99-0263 223 t•. atu: • ISSUED ANA i ed 07•`;'7/199 Issued: 0 «r "4/'199° 4444k •h * *•4M k k•4 k'k•4•k 4 *•44 khk k M•k 44*:4••4 4.4 4 k k�k* Acid e.•a: .l"r��. .M1s1 • $ ' i to :. Wrath i T b e , DEVPEP I Par't e l /r. 262304 -9UO4 •. • f • , *'k ** 444 *•k *• k, ,•k�4 :zr..:c�, s.. .n:x:nu.u^.xwi:;rus:•tsax�:t sr.<•+::•;tY�:'ti: t��•. su v��n:�sr�a:u e� ar:ziaa�:: ,.... *, J::d'a'u'.T`_`N�:a tit iS =Via" fi i ".l'.'a `. i • Peri i?t. Conditions: iNo chanties will be made to the . plans un l es appr ed by the :End ineer and the :Tutiwi to Bu:flc�ir + ±x C�tvi ^iori• Al uef mf t:c, in:,pe'.ctiorti :recor dti.` and aoor'.oyed n cans shal 1 :available,. at the ,ibb :site Ut i r to the �t any con - •, t.rur.•ticon.. Th,e: e�`documents at-e tc b'�.,maintaine't,and ava i 1- •'cable until t i al in scoet tion a is' a. nt, a,ed ctrfca1 uerrii[� : hal�1 be `obt inesci;`th :'t.he Wa.h1noton: 'State. Di0sion .oi~ Labor and Indus tr es and al ";e1ectr:i'ca1 :Ewor�t., wi 31 he .in'si)ected. -bv' that aoencv '( 7 Plumb:ina ' 'Germ7'ts "^`hai : i' be •abtaa d :th. oua`h .'the' 'Seattle i;1•6o' Countv of Pub lic ,Heal:th: Plumbirio w �l•.l be sir, e t :o ted ,�by that =�,acier.cv `includinar all . oas r,inir,o Al 1, mechanical :Wort .sha1:1 be :Under separate Perm f t issued the t i tv of:;, Tut:w i la -All ;' %on_ >tf°uct:ion to. done:i, r� n cnntomance a,ith auorovr`ed' 'a l:aiis and r•eou i r.emer.t.; of the'. Un i :i r m Bu i 1'c1 i nu Code- (1997, Edtt;t!i on) as amen•de:d.,044f orm WieChan i cal - Code (1997 Ed i ti on ) arroci ' asf thoton ',tate'Ener ov .lode (1997 .Edition) t of Permit. They icranc,e of a t or aooroval,:o p Vans soecificat-ionS :and;comoutat';ions shail' not be con ,str`ut-d to be a o cr' i mi't • tar'. or-,an aoLr'.,vai...,PI. any; VlO.lat ion .`: of any ;of; the rovi_ i' ns or the' bb ildina ,coder or of an •. at. heri;, of d i :fiance of the i urn i sd i et ion', No oer•mi t o, esum i no I to :dife' to violate or cancel ..the :vrovisionS o.t thi ' Cocics' ::Si,al.;l.:= be valid. Project Name/Tenant: Kiosk PK5 & Storage Room 5 To444 Value of Construction: 10,000.00 i e ddress: Southcenter Mall Tukwila t S y9 �i Tax 2 230 00 Property Owner: Richard E. Jacobs Grou P Will there be rack storage? ❑ yes ® no Phone: 440- 808 -7554 Street Address: 25425 Center Ridge Rd. Cleveland, City ota4 F ax 1i45 #: Contractor: Wilcox Construction, Inc. Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 Phone: 425 - 774 - 4185 Street Address: 123 - 4th Ave. N. City State /Zip: Edmonds, Wa 98020 Fax #: 425 - 774 - 4187 Architect: • Center Ridge Design Services Phone: 440 -808 -7554 Street Address: 25425 Center Ridge Dr. City State /Zip: Cleveland, Ohio 44145 Fax #: Engineer: Same as Architect Phone: Street Address: City State /Zip: Fax #: Contact Person: Dennis Morrisy Phone: WO FOE(' 7,S Street Address: 25425 Center Ridge Road Cleveland, State/Zip: Fax #: Description of work to be done: ,/ 141-k-','()-12-441 4 ,t/ /..L it/CS / 9 5 To444 0 1 Existing use: ® Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse CI Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University in Other Proposed use: ® Retail ❑ Restaurant in Multi- family ❑ Warehouse CI Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? El yes ® no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes ® no Existing fire protection features: ® sprinklers ,automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 1 .6 millioaxisting Area of Construction: (sq. ft.) 426 SF Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 in the building? ❑ yes ro: no X 11 paper indicating quantities & Material Safety Data Sheets ommercial / Multi - Family Tenant Improvement / Alteration Permit Application CITY OF TL,"WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk El Fire Loop /Hydrant (main to vauit)ff: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #f: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent If Size(s): ❑ Water Meter Temp It Size(s): Est. quantity: gal ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date alicatiiacc pledg Date apn n expires: DIXD Application by: (initials) 3r2 PLEASE SIGN BACK OF APPLICATION FORM CTPl RMIT.DOC 1/29/97 APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THELFOLLOWING:;. (Additional reviews maybe determined by the Public Works Department) ^' ❑ Flood Control Zone El Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only Schedule* BUILD/N O R OR AUTHORIZED AGENT: Signature ,, ie , C' —,�, Date: 7 21 _i'lr Print nai A ' • Rcie I F.467710M Phone:,crn et 1 /y5.'" City /State /Zi Fax #: 7 . 79 , "7 C(J,A fd�oLt� �/ . ,4,_ ALL COMMERCIAUMULTI- FAIM TENANT IMPROVEMENT /ALT TION PERMIT APPLICATIONS MUSIF SUBMITTED WITH THE FOLL NG: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) El El Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTI'ERMIT.DOC 1 /29/97 Payment Method: CHECK Notation: WILCOX CONSTR Init: TLB '********************************* * * * * ** * * * ** * * * * * * * * * * * * * * * * * * ** CITY OF TUKWILA,.WA tiC e) TRANSMIT * * * * * * * * * * * * * * * * * * * * * * ** * *tic* * * ** ** * * * * * * * * * * * * * * * * * * * * ** TRANSMIT Number: R98OO132 Amount: Permit No: D99 -0263 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 262304-9004 Site Address: 309 SOUTHCENTER MALL Total Fees: 303.56 This Payment 185.75 ,uTotal ALL Pmts: 303.56 Balance: .00 *********************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *fir * * * * * * ** Account Code Description Amount 000/322.100 BUILDING - NONRES 181.25. 000/386.904 STATE BUILDING SURCHARGE 4.50 185.75 08/24/99 12:34 0. 1. 00/25 9710 TOTAL ' 185.75 ..•.. **4.**A**k****.A*A'*“*7'***7%******A*A.A4C***i.tAllik,***Ti'*..ki** J $41-i - “*.4*** "lekli.17 . 1: :• • • ' ).1 1 • Ivnnt Met41,c111,: WILCOX1:00;;IIWCT i hit Lli rmt [0926J, type: DEVPLAM• .DEVELOPNENT •Par.0_41-0et 26:2004-9.004,. 640 EWUTHCEN1LE MALL 1 • Thie• Favment 117.81 TctEil ALL 4,10:t: 1.17.81. Oillance:; At35..P‘1; *A. ilccount Co!le AMEcr,iption• kmount • • .000/345.0 PLAN eHECk - AOORE' ,iyjeggli,4,11,,,„,tic.1.7tr577,t777.4,777.71■,fy c!''',...'177711171,11r42.1517171r411717111"11!-14;1 ',PO 07/28 1717 TOTAL 235.62 Proj t t: 6 7/tai e ttz . Typ6<af I spection: r ress: Date S ci I i struc .1 4• .t eok I u ti j4.OWe l0.'/1t/(1 eitoco• Date wanted: / // 09 Requester: n Ph'ne: �� — x 8 5 _ '�� 5'-/ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188.(206)431 -3670 Approved per applicable codes. COMMENTS: INSPECTION,RECORD . Retain a copy, with permit PERMIT NO. Corrections required prior to approval. J $4 :01 REINSPECTI at 6300 Southcenter Receipt No: Inspector: N RFQUII(ED. Prior to inspection, fee must be paid 6 vd., Suite 100./Call to schedule reins ection. p Date: COMMENTS: P-"4" " I � F lo - 1y,— ,57. �drri /f 141,q ro P- "L I I) 1L.AW -°a `ro G "0 (A-W=4 C'o4 - w slag. mo t of 1 ort., 4 0 Lg 5 I kis P(.d?a 04-c ( Spec! instructio -meP D ate wanted: q // / 9 Requester: i., d ,/°7 t7 , I ject ��� C Fb U 2 (/ 0 — �drri /f T p f spection: 1Y In 1 y� Address: mo Date called: / q .(y Spec! instructio -meP D ate wanted: q // / 9 Requester: i., d 1' Phone: 45 '36'o cljt INSPECTION NO. `INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 0 Approved per applicable codes. 42Eorrectionsreequired prior to approval. E $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project Name Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: • )677,7 Authorized Signature FINALAPP.FRM City of Tukwila Fire Department k - \\.) , .. TUKWILA FIRE DEPARTMENT Needs shift inspection FINAL APPROVAL FORM Retain current inspection schedule Approved without correction notice Approved with correction notice issued 5/, • f'll ca, Permit No. ��1 l �zba • Thomas P. Keefe, Fire Chief John W. Rants, Mayor Address r .� , �.. � c :; LL Suite # III \<4e1 Date Rev. 2/19/98 T.F.D. Form F.P. 85 • Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 PLAN REEW R/ OUTING SLIP ACTIVITY NUMBER D99 -0263 DATE 7 -28 -99 PROJECT NAME. . KIOSK PK5 STORAGE ROOM X Original. Plan Submittal Response to Incomplete Letter Response to Correction Letter # Revision # After. Permit Is Issued DEPARTMENTS: Ven Building Division Av Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete I I Comments: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required ri REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved WRROUTB.DOC 5/99 Fire Prevention Structural A Planning Division I - 1 Permit Coordinator DUE DATE: 7 -29 -99 C 0 Not Applicable rI DUE DATE 8-26-99 Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions C Not Approved (attach comments) C REVIEWER'S INITIALS: DATE: Fire Department Review Control #D99 -0263 (512) Dear Sir: City of Tukwila Fire Department Re: Kiosk PK5 storage room - 640 Southcenter Mall July 29, 1999 John W Rants, Mayor Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 Thomas P. Keefe, Fire Chief Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) John W. Rants, Mayor 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) No articles, displays or other materials shall be hung on or from sprinkler heads or piping. Remove the Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 57$4439 Page number 3 Thomas P. Keefe, Fire Chief item(s) in violation and refrain from this practice in the future. (NFPA 13 -2- 6.1.7) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, .e v The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 r-62S- 052 -OOO (8f97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ?::REGIST: #'_ :0001 ILGO *19 45 EFFECTIVE( DAT ' iii:.. > WILCOX CONSTRUCTION INC 123 4TH AVE N 'EDMONDS WA 98020 0/ 19'99, 8 1 �y1�j20./19� The Richard E. Jacobs Group 25425 Center Ridge Road Cleveland. Ohio 44145-4122 Phone: 218-871-4800 TITLE SHEET GENERAL NOTES KEY PLAN K K rn 11 > 0 0 E E > (f) Z Z rn Z 0 r Z rnni rn rn " • 0 0 (r) r 70 t 0 0 L; 1 cn - I) m > Z 11 - ncn > 1 0 71 1 F I SOUTHCENTER MALL TUKILA, WASHINGTON Center Ridge Design Services, Inc. Architects - Engineers 25425 Center Ridge Road C1,7eland, Ohio 44145-4122 Phone: 218-971-.00 RICIIP110 WR6 STATE OF WASHINGTON CO 0 rn z rn NJ rn -A ru O. A g o 2 g ji . . Wi 7.1 4 cn 0 V WO gPgWPM qiNW 4 PM 0 !g0 ugA k RO 5 . 4 q pi 4 Ntge R,, 5 btu 01 qp64 P g 4 ih e " Ppagp plo q g 4 IP 644 , 41 q 01 00 t490 5 1 0 i 4 0114 PAPp 01 1 4 , gi i g AO lel A r Iii IPL 4 g V?4g 8' P 4 . Ng V a t 11/ _ ggl. k 6 11 g g40 44 f Ink 1 44 _ P _ .‹., rt . 41 2 10 pA . ' r 0 O4 -1 (0 t. N gg > g Y1 14 °g g 11 1° IP' gII 6%8 ;J g, gre 11$ q 1,01 151 11,0 Wgi A 2 0 1 Oil i2g -§g g 1 ii I d 2 1"E 1; 1Pgi 10 4 g m > ;10 'i $I Npg 0 14 I 1 0 11 rl R I g s h 141 i g ! h p 1 g s, P bll 11 hilkol ige 1 11 Fiq "I; gilg§gi 4 41 $ 141griX P'g 2 g 1 gm i 1 8 9 ilEA R gloglig 54 40 Ogil 1 1143 2 i 1 ggi §0,0144144 V114;10% pi la ii P40 Iii 111 ;11 -g Pi t 9 i g i li 11,1 I li 1 4 011111 if k iit 8 g 1 41 , 8 z 0 0 rn 7c) 0 0 - n r 0 0 r 1; z 8 z 111 0 24 2N-0* I The Richard E Jacobs Croup Nemeor masear Nair 25425 Center Ridge Road Cleveland, Ohio 44145-4122 Phone: 218-871-4800 T N KIOSK FLOOR PLAN ( PK5 ) STORAGE ROOM FLOOR PLAN ii r- 0 0 0 0 rn cn 0 0 rn SOUTHCENTER MALL TUKWILA (SEATTLE), WASHINGTON Center Ridge Design Services Inc. Architects — Engineers 25425 Center Ridge Road Clevelend, Ohio 4-4145-4122 Phone: 216-871-4800 cn 24 STATE OF WASHINGTON 0 a\ 1 STI.b''S. r WALL AT DOWN RIB - WALL AT (P RIB SECTION AT WALLS LOCATED PARALLE - TO ROOF DECK RIBS 6' -0' 0/C MAX, 6•-0• O/C MAX, ' ` l 6 O/C MAX. SECTION A-A SECTION 8-B SIMTION AT WALLS LOCA 1 aD MiRMENDICLILAR TO ROOF DECK PBS MIN. 3' X 20 GA METAL STUD- B DO NOT ATTAO-I BED FLANGES TO FIT INTO DECK RIB. TO N ETAL SLIP JOINT DETAIL AT DECK DIAGONAL LATERAL BRACING IS SIMILAR TO 14-NG AND PARTITION WALLS. 5/8 F.R. GYP, ED. TO DECK ABOVE PROVIDE 3/4 SPACE, AS SHOWN, FOR DEFLECTION PROVIDE METAL STUDS ( 20 GA. ) AT 7 -O' OC. W/ I- )ORIZONTAL STIFFENERS AT 10' -O O.C. (MAX) ( DO NOT ATTACH TO TOP TRACK ) DO NOT TAPE TOGTI-ER CONTWJOUS COLD ROLLED STEEL CHANNEL, SNAPPED INTO SLOT W METAL STUDS. LOCATE AS FOLLOWS A) 7-0' (MAX) BELOW TOP SUPPORT TO HOLD STUDS VERTICAL B) IO'-O' 0. C. (MAX) TO DISTRIBUTE LATERAL LOADS THIS CONTRACTOR S -LAIN- PROVIDE DEMISING WALL FULL I- EIGHT, INCLUDING SLIP JOINT, WITH 5/8' FR. GYP BD FROM FINISH FLOOR TO SUP JOINT ABOVE PROVIDE DIAGONAL BRACING WI-EN HEIGHT OF WALL EXCEEDS .MFG. 1-EIGHT REQUIREMENTS. WALL ASSEMBLY 6' 20 GA. METAL STUDS AT 24 O.C.WITH MID - SPAN STIFFENERS AND 5/8' FR. GYP BD 8011-4 SIDES. I HOUR FIRE RATED ASSEMBLY. SECURE BOTTOM TRACK TO FLOOR. CONCRETE FLOOR. VERIFY IF EXISTING. SCALE 3° -r -O° CLEAT k � 3' MN. B DEEP SLIDE TRACK AT ROOF DECK 0R BOTTOM CF JOISTS. see PLAN FOR LOCATION ROOF STRUCTURE ABOVE VERIFY ELEVATION. NONA:E. A,. DECK CONSTRUCTION. 20 GA GALS METAL FIRE TRACK SHADOWLIN= W/ SJP OJP W/2 WAFER kEAD FSC.EEWS AT F.A cm SLP CUP. 2 CLIPS ON EACH METAL STUD. MFG. PRE CORP. 1-80 OR EQUAL UL S :'STEM NO. 1-1W-S0012 PROVIDE ADDITIONAL SCREWS STUDS DO NOT F INIT E WITH fA WALL MIN 31/7 METAL STUD O/C MAX. MK 9 V?1.1 . Gl0 WSW MO COM HUNG SOFFITS SUPPORTED SIMILARLY, WITH ADDITIONAL HANGER WIRES FROM WALL BRIDGING LP TO ROOF JOIST BOTTOM CHOR AT 6' -0' 0 /C. DETAIL AT METAL DECK SCALE 3' -I' -O' ONE 1 -1OUR FIRE RATED. PK5 SLIP JOINT IET441..AT NON-METAL TAL DECK DETAIL AT NON-METAL DECK ONE HOUR FIRE RATED. PK5 WI-BJ 5/8' F.R. GYP. ED. RUMS PARALLEL TO META. DECK I NONMETAL DECK FLUTES, EXTEND 5/8' FR. GYP. ED. TO TO P OF DECK. PROVIDE FIRE SHIELD SEALANT AT JOINT. AND WIEN 5/8' F.R. GYP. BD. RUNS PERPENDICULAR TO METAL DECK / NONMETAL DECK FLUTES, EXTEND 5/8' FR. GYP. B4). TO TOP OF DECK, AND CUT GYP. ED. TO CONFORM TO PROFILE OF DECK PROVIDE FIRE SHIELD SEALANT AT JOINT. VERIFY EXISTING ROOF ASSEMBLY CONSTRUCTION. IF ROOF STRUCTURE IS A METAL DECK, USE METAL DECK DETAILS ON THIS SHEET, IF ROOF STRUCTURE IS A NONMETAL DECK, IjSE NONMETAL DECK DETAILS ON THIS SHEET. LANDLORD'S CONTRACTOR SHALL PROVIDE DEMISING WALL. FULL I- EIGHT, INCLUDING SUP JOINT DETAIL AT LEAD. PROVIDE 5/8' FIRE RATED GYPSUM BOARD FROM FINISH FLOOR TO SLIP JOINT ABOVE AS DETAILED. METAL STLD WALL TO LW 6' X 20 GA. STUDS AT I6' O.C. WITH MID SPAN STIFFENERS. PROVIDE DIAGONAL BRACING WI-EN FIGHT OF WALL EXCEEDS TI-S RECOMMENDED MANLFACTI'S HEIGHT REQUIREMENTS. EXISTING OR NEW CONCRETE SLAB ON GRADE OR CONC ETE TOPPING ON STRUCTURAL DECKING. SEE FLOOR PLAN VERIFY IN TI-E FIELD, IF FLOOR NOT EXISTING PROVIDE NEW CONCRETE FOR WALL SUPPORT PER DETAILS AND TO MATCH EXISTING. IF NEW CONCRETE SLAB ON GRADE IS REQUIRED. PROVIDE 4' CONCRETE SLAB WITH EX6 10 /10 W.WM. OVER 6 MILLIMET VAPOR BARRIER OVER MINIMUM 4' WAS-ED GRANULAR FILL, OVEN WELL COMPACTED EARTH. FIRST CONSTRUCTION POUR TO EXTEND W.WM Z -6' BEYOND END OF CONSTRUCTION AT DEMISING WALL, AND EXTEND CONCRETE POUR 7 BEYOND CENTER LINE OF DEMISING WALL I SECOND CONSTRUCTION POUR TO EXTEND CONCRETE FROM SLAB LNOM DEMISING WALL IN70 TENANT SPACE. TIE INTO AND EXTEND W.W.M. WHEN EMENDING CONCRETE POUR. WALL CONSTRUCTION SHOWN SHALL BE A ONE HOUR FIRE RATED ASSEMBLY. U.L DESIGN NUMBER U465. SEE DETAILS. EXISTING CONSTRUCTION VERIFY MATERIALS FIRE RATED SEALANT COM 20 GA GALV. METAL FIRE TRACK WWI W/ ILE SCR T SCREWS AT EAOI-I SLIP OJP, 2 CLIPS ON EACH METAL SILO ( FUZE TRACK CORP. I- 800 394 -9875) OR EQUAL, U. SYSTEM NO. MN - S - 0013 5/8' FR. GYP. 80. W/ METAL BEADS ON CORNERS. BOTH SIDES FIRE TAPE AND CONFOUND (30TH SIDES r GYP BD. SCREWS •7 -O O.C. TIE TO MTL STUDS COM'. COLD ROLLED STEEL 04AN EL SNAPPED O � SLOT IN METAL STUDS AS A. 7 -0' ( MAX ) BELOW TOP SUPPORT TO HOLD STUDS VERTICAL a )10'0' 0/C ( MAX.) TO DISTRIBUTE LATERAL LOADS ( HORIZ, STIFFENERS ) 5/8' FR. GYP. BD. /LLL JOINTS TO BE TAPED AND SANDED. 11-RS FIRE RATED ASSEMI3LY ( UL NO. U465 ) WHERE REQUIRED. DETAIL AT STEEL BEAM SCALE 3' •I'-O' ONE 1-1OUR FIRE RATED. PK5 DO NOT TAPE TOGETHER �— METAL STUDS. NESTED INTO THE FLUTES OEM SPANNING GETWEEN JOISTS /f ' tL TO LATERALLY ILPFORT TOP CF WALL. BEND TO PIT DECK FLUTES. PROVIDE CLEATS AT 0A0H END TO KEEP FROM SHIFTING. SECTION A ROOFING OVER INSULATION, OVER METAL DECK ROOFING OVER INSULATION, OVER METAL DECK —FILL VOID SPACES WITH COMPRESSIBLE TI- ERMAFIBER INSLLATION 20 GA GALV. METAL FIRE TRACK SHADOWLINE W/ SLIP CLIP W/2 WAFER I-EAD SCREWS AT EACH SLIP CLIP, 2 CLIPS ON EACH METAL STUD. MFG. FEE TRAK CORP. 1 -800 -394 -9875 OR EQUAL. U.L. SYSTEM NO. NW- S -0012 PROVIDE ADDITIONAL SCREWS 13FTWEEN STUDS. DO NOT INTERFERE WITH COMPRESSION ACTION OF WALL WALL ASSEMBLY 6' 20 GA. METAL STUDS AT 7 -0' O.C. WITH MID - SPAN STIFFENERS AND 5/8' FR. GYP BD ON BOTH SIDES. ONE HOUR FIRE RATED ASSEMBLY. 5/8' F.R. GYP. BD. TO DECK ABOVE PROVIDE 3/4' SPACE. AS SHOWN. FOR DEFLECTION. PROVIDE METAL STUDS ( 20 GA. I AT 7 -0' O.C., W/ HORIZONTAL STIFFENERS AT IO'-0' O.C. ( MAX I ( 00 NOT ATTACH TO TOP TRACK ) CONTINUOUS COLD ROLLED STEEL CHANNEL, SNAPPED INTO SLOT IN METAL STUDS. LOCATE AS FOLLOWS A) 7 -0' (MAX) BELOW TOP SUPPORT TO HOLD STUDS VERTICAL. B) IO' -0' O. C. (MAX.) TO DISTRIBUTE LATERAL LOADS. THIS CONTRACTOR SHALL PROVIDE DEMISING WALL FULL I- EIGHT, INCLUDING SLIP JOINT, WITH 5/8' FR. GYP BD FROM P02514 FLOOR TO SLI^ JOINT ABOVE. PROVIDE DIAGONAL BRACING WHEN I - EIGHT OF WALL EXCEEDS MFG I -E151-IT REOUIREMENTS. oECLRE BOTTOM TRACK TO FLOOR SLIP JOINT DETAIL AT DECK DETAIL AT METAL DECK SCALE 3'-1'0' ONE HOUR FIRE RATED. PK5 WI-EN 5/8' FR. GYP, BC. RUNS PARALf3 TO METAL DECK NONMETAL DECK FLUTES, EXTEND 5/8' FR. GYP. BD. TO TOP OF DECK. PROVIDE FIRE SHIELD SEALANT AT JOINT. AND WI-EN 5/8' FR. GYP. 80. PANS PERPENDICULAR TO METAL DECK / NONMETAL DECK FLUTES, EXTEND 5/8' FR. GYP. 90. TO TOP OF DECK. AND CUT GYP. BD. TO CONFORM TO PROFILE OF DECK PROVIDE FIRE SHIELD SEALANT AT JOINT. FIRE RATED SEALANT, CONT. STEEL BEAM, OR JOISTS fo I-5/8' STL RUN 046/4 BRACKETS • 24' O.C. W/ I -3 /8'X7 /8' CORNER ANGLES ATT. TO CHAN. BRACKETS ( U. NO. N5OI ) WI-ERE REQUIRED. FIRE TAPE AND COMPOUND BOTH SIDES DO NOT TAPE TOGETHER PROVIDE 6'X20 GA. METAL STUDS • I6' O.C. W/ 1-IOR7 STIFFENERS AT IO'-O' O.C. WITHOUT TOP CIAN/-0L A-2 SOUTFHCENTER PK5 0