Loading...
HomeMy WebLinkAboutPermit D99-0300 - National Envelope - Storage Racks, , , • `r L•••; i.••••• 0.• National Envolope City of Tukwila ( Parcel No: Address: Suite No: Location: Category: Type: Zoning: Coast Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: OCCUPANT OWNER CONTACT CONTRACTOR 352304 -9018 18296 ANDOVER PK W AWSE DEVPERM M2 001 North: HIGHLINE Contractor License No: LAPIALP055MZ Permit Center Authorized Signature: Signature: DEVELOPMENT PERMIT Fire .0 South: .0 East: Sewer: SEPTIC Slopes: N Occupancy: UBC: Protection: .0 West: Streams: (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 T e DvA v. WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. ISSUED Permit No: Status: Issued: Expires: 03/12/2000 WZ 00 WAREHOUSE 1997 SPRINKLERED .0 Phone: Phone: (206) 575 -2000 Phone: 206 - 575 -8378 Phone: 206 575 -2000 NATIONAL ENVELOPE 18296 ANDOVER PK W, TUKWILA, WA 98188 LA PIANTA LTD PARTNERSHIP PO BOX 88050, TUKWILA WA 98138 JERRY SOIJZA 18221 ANDOVER PK W, TUKWILA, WA 98188 LA PIANTA LIMITED PARTNERSHIP P.O. BOX 88050, TUKWILA, WA 98138 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL WAREHOUSE RACKING. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Gut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Mairi Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 68.44 ************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date: 9_1'7 9 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign for and obtain this development r. mit. oits.442&_....1.446.44/AA):: Date: 9_: -7? Print Name:_ __.------------__-- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned For a period of 180 days from the last inspection. City of Tukwila Z Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: Print Name: WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Signature:___ 352304 -9018 18296 ANDOVER PK W AWSE DEVPERM M2 001 North: HIGHLINE Contractor License No: LAPIALP055MZ OCCUPANT NATIONAL ENVELOPE Phone: 18296 ANDOVER PK W, TUKWILA, WA 98188 OWNER LA PIANTA LTD PARTNERSHIP Phone: (206) 575 -2000 PO BOX 88050, TUKWILA WA 98138 CONTACT JERRY SOUZA Phone: 206- 575 -8378 18221 ANDOVER PK W, TUKWILA, WA 98188 CONTRACTOR LA PIANTA LIMITED PARTNERSHIP Phone: 206 575 -2000 P.O. BOX 88050, TUKWILA, WA 98138 *******************•********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL WAREHOUSE RACKING. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 68.44 ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Permit Center Authorized Signature: _ C�IY'NYY1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. .0 South: Sewer: Slopes: 7 DEVELOPMENT PERMIT (206) 431 -3670 Permit No: _D99 -030 Status: Issued: Expires: Occupancy: WAREHOUSE UBC: 1997 Fire Protection: SPRINKLERED .0 East: .0 West: .0 SEPTIC N Streams: '6:Q - Date: cL--3- c1(1 Date: 9 -/3.. 7? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ANDOVER pK' W Permit N Address: 18296 Tenant: ?;Type: DEVPERM Parco 1 II: 352304-9018 *** k**************'* * ***k*************** *** *�►t * *' Permit: Condi:tioris: 1 . No. changes wi 11 be made to the plans unless approved by the ,Engineer arid the Tukwila pui lding Al • ! 1 permits, inspection records, ',:arid • ::approved plans shal 'k be ava i l able at the .lob : -site prior to the st o F any con •structi on. These ' documents' are, to be maintained and avail- able until f .1 rispeati _approval is granted All construction' to ;.be dorie i n coriformanre., with approved plans and requi rements `o f .,Urii form: Bu i l d i rig :Code (1997 • Ed i t i o& as ;, amerided, Un i .Form Mechanical' Code (1997• Ed i t:i`ari) and Washington State Energy .Code `(1.997 Edition) • Val.idnt -y`;of Permit The issuance'`of a permit' or approval of p1ans, and computations shall not be `con strued to be: `a permit For, or an approval of, any ; . v i of airs on of any c � F the p r o v i s i o n s of the bu i 1 di r►g code or of any_ other or.d:inarice of the,jurisd ction. „: No permit presuming t, •give author i to violate or : canoe l : the provisions o f this ;. code`, .'shall be valid. • t.11 OF l "L11.W1,L14. .. Adclilesti;: i,329( AN(OVEFS' P. W : Perni r t No: 'ci.i ran t te :� t a t:u . • 1'v.>je: i'Eirf'EI FI AOD lied: 1- ,I.a 3t)2304-9018 '.Issued: 4k4F4'4:4. 4 44444.4' 444'k:4. 4444. 4' 44. 4444•k4.'44.4'4'44.4.4'4.4t4'4. 4444• k' 4;4k•4•4k'kk44'4F•4•4•4k.'444 4.4444.4 P .eI' illi.t {.. d •l on,t.on�. i`:: 1 '1No t: fi aftoe'"-• wi 11.,:: be inade to -- the :o,l an - ,.uri 1 es.s, aDuroved by the Erra:i iteer and the i l;ul w i °.1;a E3u:i'1.d4ni , D.;.1.i i :..i orb . tl l ..pen .m ,ins.pac:t l n records. and nr ov. d' o Van_ Hsha 1 1 be ;j,v 'al ,l; b1e:at'• i site ;Ol :zr ro;the star t`c.►t arty cOn= ,str.ucti T hetie ri6:ime.nt: are t.o b , maint,:3iri ed anci avai 1- `abt titytll tiria1 i`nsDec�,tion L i) ovLs1 , 1s Qt.:ai,te'd . Al 1 cc'nstt :toi b'e done trt ..:00t.tt�i�nian6e . °w th:� aot r.oi� ed*. i3.l.ary_; a rrc1 � r.ec.iu1r eni;ert �, t o.i the.Onit'ornr''£tug 1 dina ' i dcie (`.1,99 Ed it i on; r` aipendeid ...Llri i T onoi NNlechnn i cal Code . (1 u 97 :Ed i`t•1 on ): :: •„an 1 W,a,sh n9toni' to Ener.9v. ',Lode t:.199? Ed 7 t ion.) Va 1 t ci`;i tv : of F'er nri t , l ; �' ;uarrce s�.t' 8 uerni i t `'�r arib► "u. of :D ltiar)i..i, "De,t.if ic�atioris ! a tici 'corm ut tlrt:-'.� shall riot ti e= c ori -` 'str ued to;,be. a perm it ;for .or::. ap t. i' pt -oval of antis vt.oilation, `an of the r'rov i 1 g.ns of. the bti .ld i n9 code or` any.. ' of a' :or `or.hei,r or.d pan ce .cif;. the :.iur l'dic.tion. NO berm it ores to ai;ues<atith to ;'vi`o:la.te, or can e.t: th.e: Lir.ovi_ ion ; .o•t this : cod+ `: sha:l 1 he va'l..i d. D99 -1 00 APPROVED, a24 /19 Project Name/Tenant: / a[iona l 6 e/0 te Valueppf Construction: f OQ�� , D Site Address: J pity State/ p: i /(, 44,10.6/ Q /4- (A.). /r1y4co// T P Numbe 5 a Soy 9 a / PropertyOwner: / f i v`Slf ?PS ��✓ l C ! ,. Phonp2\ J ,S7SUDb c Street Address: / , � /City State /Zip: 1 6 I - b o ti A/L w. / U , / w m Fax #: - ( 9 - 6 ( 0 6 7 5 : - / B - 7 Contractor: Phone: Street Address: City State /Zip: Fax #: Architect , {r L ot Lone W' D s ((� ,SyS eivl e / Phor\:z 7,7.2. -5% Street Address: City fate /Zi '7 74 / li vP . I Sea /e GJa, 7R /Do Fax #: C NO 7 G-5 3 b( Engineer: `/ Pigl S. /7/7f/".5 itssbc /2 /cs Phone (IS') sc/q_6G ?Z Street Address: / Eit State /Zip: / ,22. -5 7- P . kor i-4 Ida ciiCc �fena�/ Cry_ y�z�:L Fax # ( / , �(�'- Gb7y Contact Persian : r ( n I .7€ f y JcuzC- -- IVait6 640d01 .0 Phone: t�OU5 (ploq y to be) �i"7S Y37 Street Address: y State /Zi /�'.��r �i1�ovc'v //4 �� 2.1,/,,,,,/, City Fax #: ‘ zo 6 St S'�i�- Description of work to be done: h51_a.) / lea /e1 Q ut9Se /fir. c -fh Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family aWarehouse ❑ Hospital ❑ Church Cl Manufacturing Cl Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail CI Restaurant El Multi-family Warehouse CI Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes ❑ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? 71 yes ❑ no Existing fire protection features: in sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 1) existing Area of Construction: (sq. ft.) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes IP no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF T► 'KWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY ject Number: Permit Number: OOb Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ❑ Channelization /Striping ❑ Fire Loop /Hydrant (r aii CI Land Altering /(',. ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Water Meter /Exempt it: APPLICANT REQUEST PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING : .. (Additional reviews may be determined by the. Public Works Department) ❑ Curb Cut/Access /Sidewalk ❑ Flood Control Zone to vault) #: / Sizeis / ,�- i ut' , /uti y fl :i-.lcy,�ill- /- cubic yds. d/andscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Hauling Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure wflib64b(iiiived and is subject to possible revision by the Permit Center to comply with current fee schedules. CITY OF TUKWILA Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of appliclijbh714p1 f limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be ext lne{elpgp once. Date applicatioce: oaf ‘ft. "2. Date application exp s: a - Appj4tfon taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERM!T.DOC 1/29/97 BUILDING O NER OR AIrJ1 HORIZED AGENT: Signature: � A�j l rr� ( � V ►.,. , 1 fie ' + Date: r Fax # y .� �S�S SA Print name: Q- f (` ! J i �, I y U ,k z Phone' o . � �, �� .43 TL f� Address / L4 /ti/F�-�,t) p/ CityI Late /Zil! �� 9 / /11 ru cL ALL COMMERCIAUMULTI- FAMTENANT IMPROVEMENT /ALT TION PERMIT APPLICATIONS MUSITIt SUBMITTED WITH THE FOLLO ING: DRAWIN S'TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) • 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ 51 Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 ill 7k*7k*** **** **** *7k*7k** ******* (****** f1k7k**** * *7ti**** **'*** * ***1k**1k*** CITY OF TUKWILA, WA TRANSMIT * * * * * * * * * * * * * * * * * * * ** * *** * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TRANSMIT Number: R9800132 Amount: 68.44 08/24/99 11:56 Payment Method: CHECK Notation: NATIONAL ENVELOP Init: CAS Permit No: D99 -0300 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 352304 -9018 Site Address: 18296 ANDOVER PK W Total Fees: 68.44 This Payment 68.44 Total ALL Pmts: 68.44 Balance: .00 ********************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Account Code Description Amount 000/322.100 BUILDING - NONRES 38.75 000/345.830 PLAN CHECK - NONRES 25.19 000/386.904 STATE BUILDING SURCHARGE 4.50 6270 09/25 9710 'TOTAL • Project: JUATOL/AL e•ti ife-COPe Ty of Inspection: Address: Date ca : Special instructions: Date wanted: / i 15 0 0 P.m. Requryw i 1 lak A Phone: • INSPECTION RECORD Retain a copy with permit - INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Approved per applicable codes. El Corrections required prior to approval. 7i) inspe Datu / $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project: )Ct;\\ c•, t a...l E: ► -- OrC \ "C Type of fnst�cti n: •---- • I i C C f'`i V Add e t i • � J Date called: 1 - 1 1 r - DCC Special instructions: Date wanted: _ , a a. .m. I ( -=� Requester: �21) )c(AM 1' \a■ - tC\ `�C.t /Phone• ,I .) -� I li Lt } I. - - - ..77.5 -1 .. "7 l `. INSPECTION RECORD Retain a copy with permit INSPECTION CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188, PERMIT NO. (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Oil ,nr 7216 bgess oP1'c. 5SO% c6 0 $47.00 REINSPECTION FEE REQUIRED. Prior to insp:ction, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: Project: ]'' / a 6 ii a ` t a ��,Type of Inspection: .. I Address! � r Ap Date called: Special 1 i ` nstructions Date wanted: <1 04 0 Requester: (A) h( Phone: _.,/ s _ 75 ...._ 0 7i ". INSPECTION NO. INSPECTION RECD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southc Blvd, #100, Tukwila WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspects n. Receipt No: Date: INALAPP.FRM City of Tukwila Fire Department Needs shift inspection TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name /1/1• / Cam. PJ Address ii % 9G 4 F`kJ' Retain current inspection schedule Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature /W "1 , f/• John W. Rants, Mayor Thomas P. Keefe, Flee Chief Permit No. D' 1 ,79 .--01 ,3 062 Suite # Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57S•4404 • Fax (206) 575.4439 Notic If this calculation is submitt . for calculations as listed in the : ble by all drawings listed in S• tion,l: A in ink of a contrasting cq or wit signed across this block./ REPRODUCTIONS National Envelope Republic Racks Location: 18296 Andover Park West Tukwilla, WA (Zone 3) Prepared For: National Envelope Corporation - Northwest Tukwila, WA Prepared By: Peter S. Higgins And Associates Consulting Structural Engineers 1225 -F North Pacific Ave. Glendale, CA 91202 (818) 549 -0072 Peter S. Higgins, S.E. Job Number 3888 August 19, 1999 This Document and the desiga..1 is provided as an instrumepr of service, the written permission pfPeter S. Higgi IS c right by Peter S. iggins and Associates. It all not be r • • duce in any fashion without and Asso s. 'ng Departure s g permit fipproval, / s hall contain all sheets of is on the/next page(y , and shall be accompanied ments hall bear a t t opriate seals and signatures e Job li mber Ref nee. The calculation shall be ' r COPIES ARE INVALID 5EP 0 9 1999 AS SOCED UILC�h G 17i 0 RECEIVED CITY OF TUKWILA AUG 2 4 1999 PERMIT CENTER D 99 -0300 0�3 Table of Contents PETER S. HIGGINS AND ASSOCIATES CONSULTING STRUCTURAL ENGINEERS Project: National Envelope August 19, 1999 1 Reference Data 1 1.1 Documents 1 1.1.1 Drawings 1 1.1.1.1 By Peter S. Higgins and Associates 1 1.1.1.2 By Others 1 1.2 Loads 1 1.2.1 Vertical (Dead plus Live) 1 1.2.2 Seismic 1 1.2.2.1 General (UBC 2222) 1 1.2.2.2 Short Formulation 2 2 Basic Configuration 2 2.1 Components and Geometry 2 2.2 Check Beams 2 2.2.1 Design Forces 2 2.2.2 Beam Properties 3 2.3 Check Posts (Dead plus Live Loads) 3 2.3.1 Load to Post 3 2.3.2 Post Properties (net section) 3 2.4 Longitudinal Seismic 3 2.4.1 Base Shear 3 2.4.2 Design Forces 4 2.4.3 Post - Combined Stresses 4 2.4.4 Beam Connections 4 2.4.4.1 Design Forces 4 2.4.4.2 Connection Capacity 4 2.5 Transverse Seismic 5 2.5.1 Base Shear 5 2.5.2 Design Forces 5 2.5.2.1 Stability 5 2.5.2.2 Brace 5 2.5.2.2.1 Design Force 5 2.5.2.2.2 Brace Capacity 5 • yright lig Associates. Provided as an instrument of service. Copying by written permission only. M Job No. Sheet ii Project: National Envelope August 19, 1999 PETER S. HIGGINS AND ASSOCIATES CONSULTING STRUCTURAL ENGINEERS 1 Reference Data This calculation reviews the installation of storage racks for structural adequacy. The sealing of draw- ings is for the structural review of the storage racks only. Other information is not reviewed, nor approved. This is a relocation of storage racks originally reviewed by this office in October, 1995 (Job No. 1981) and installed under permit. They are being moved to another building within the City of Tukwila. This calculation reviews this material to current code. 1.1 Documents 1.1.1 Drawings 1.1.1.1 By Peter S. Hiegins and Associates RP - 1 1.2 Loads 1.1.1.2 By Others Conesco NATE129 (7- 21 -99) Approved as noted (for material) 1.2.1 Vertical (Dead plus Live) Loads per level = 3.6 kips Design beams for 25% impact 1.2.2 Seismic 1.2.2.1 General (UBC 2222) 0.11C a lit/ 51/ = R T 11 < 2. SC a l Where: For default soils: C =0.36 Cv =0.54 Soil Profile Type =SD 1 =1.00 Substitution yields: _l 0.069 9 0.02811 1,�<_ 0.115W < / ton — 0.0281i/ <_l/ — 0 'T 8 trans 0. rans 14' < _ 0.146l✓ For working stress designs: R= (1.4)(5.6) =7.84 Longitudinal (moment frame) (1.4)(4.4) =6.16 Transverse (braced) T= Structure Period (sec) W= Rack +Contents per 2228.5.1 °Copyright by Peter S. Higgins and Associates. Provided as an instrument of service. Copying by written permission only. Job No. Sheet 1 RECEIVED CITY OF TUKWILA AUG 2 4 1999 PERMIT CENTER Project: National Envelope August 19, 1999 PETER 5. HIGGINS AND ASSOCIATES CONSULTING STRUCTURAL ENGINEERS Job No. Sheet 2 1.2.2.2 Short Formulation If racks are interconnected such that 4 posts in each direction resist lateral load, then using code maximum loads, and W =rack rated capacity: V 1ang 5_0 .11514/= 0.115(DL +LL /2) . 0.06014/ 1I trans � 0. 1461-,/= 0.146(DL + 0.075!V (since DL < < LL) This condition is usually satisfied by interconnecting back to back rows of rack, or by tieing single rows across the aisles. 2 Basic Configuration 2.1 Components and Geometry W W =131" a =78" b =78" Beam Type G 2.2 Check Beams 2.2.1 Design Forces L M (2)(8) =36.8 inch kips 1 1 H =156" D =42" 1 = 44" 1d =58" Upright Type Min. C < M Smin 30 =1.46 in °Copyright by Peter S. Higgins and Associates. Provided as an instrument of service. Copying by written permission only. r Project: National Envelope August 19, 1999 2.2.2 Beam Properties 2.4 Longitudinal Seismic 1 T> 2300 V II/L3 1 (2n2 +2n+ 1) PETER S. HIGGINS AND ASSOCIATES' CONSULTING STRUCTURAL ENGINEERS G Beam t =14 ga S =1.70 in I =5.24 in 2.3 Check Posts (Dead plus Live Loads) 2.3.1 Load to Post 2.3.2 Post Properties (net section) [PICTURE] P < (tl of levels)(L) 2 =3.6 kips C Column t =14 ga A =0.63 in S =0.75 in r =1.33 in r =1.10 in 1 /ry =40 as /rx =59 F =20.0 ksi P =12.6k 11 Xa = 18.9a Where: W = Load per level L = Spacing between levels I = Moment of inertia of post n = Number of levels O.K. 2.4.1 Base Shear Determine Period - Rayleigh Method - UBC Method B. Derivation supplied upon request. Units: kips, inches, seconds RECEIVED CITY OF TUKWILA AUG 2 41999 PERMIT CENTER °Copyright by Peter S. Higgins and Associates. Provided as an instrument of service. Copying by written permission only. Job No. Sheet 3 i.4 • Project: National Envelope August 19, 1999 2.4.4 Beam Connections ( -) PETER S. HIGGINS AND ASSOCIATES CONSULTING STRUCTURAL ENGINEERS Substituting yields: T> 1.9 sec Thus: V <0.045W 2.4.2 Design Forces P <3.6k; V<0.16k M < Va- (1.3)P < (0.16)(78) - (1.3)(3.6) = 8.1 inch kips 2.4.3 Post - Combined Stresses 2.4.4.1 Design Forces Mconn < 8 . 1 " k 2.4.4.2 Connection Capacity P M P M M =0.72 <1.33 O.K. Standard Connection M (1.33)(2.3)(4)= 12.3in k O.K. Job No. Sheet 4 `. (fixity due to width of base plate). Effective throat of hook = 0.875" X 0.188" = 0.164 in Allowable Shear on Hook = 2.3 kips °Copyright by Peter S. Higgins and Associates. Provided as an instrument of service. Copying by written permission only, Project: National Envelope August 19, 1999 2.5 Transverse Seismic 2.5.1 Base Shear Use Short Formulation V= 0.075W =0.54k 2.5.2 Design Forces 0 ± P EQ 2.5.2.1 Stability Peg < PD +L - Stable -No Uplift. Anchors provide added Factor of Safety. Use min. 3/8" diam. ICBO approved expansion anchors. Minimum embedment 2" into slab. O.K. 2,5.2.2 Brace 2.5.2.2.1 Design Force Pb <0.8k 2.5.2.2.2 Brace Capacity V 1 1.50 PETER S. HIGGINS AND ASSOCIATE CONSULTING STRUCTURAL ENGINEERS _ V /z' PQq D h' =117 inches P =1.5 kips Note: Bracing shown is schematic - see this section, subsec- tion .2 for actual geometry. t =14 ga Anet = in r =0.33 in Job No. Sheet 5 RECEIVED CITY OF TUKWIIA AUG 2 41999 CCopyright by Peter S. Higgins and Associates. Provided as an instrument of service. Copying by written permission only. PERMIT CENTER • •, • t 1 1, • , • 1 • • . "•• ' • . - , :,„ • , ••• „ • „.• ( — PETER S. IIIGGINS AND ASSOCIATES CONSULTING STRUCTURAL ENGINEERS Project: National Envelope August 19, 1999 °Copyright by Peter S. Higgins and Associates. Provided as an instrument of service. Copying by written permission only. Job' Sheet 6' e W 1 Type C e A -F 1.50 1.00 G-J 2.44 1.00 Type W D (ga) As Sx rx ry A 3.00 1.63 14 0.44 0.47 1.26 0.63 B 3.00 1.63 13 0.51 0.54 1.26 0.62 C 3.00 3.00 14 0.63 0.75 1.33 1.10 D 3.00 3.00 13 0.74 0.87 1.32 1.09 E 3.00 3.00 12 0.86 1.00 1.32 1.08 F 3.00 3.00 10 1.08 1.22 1.30 1.06 G 4.00 3.00 14 0.71 1.08 1.74 1.12 H 4.00 3.00 12 0.83 1.25 1.74 1.12 J 4.00 3.00 10 1.21 1.78 1.71 1.09 , i Type A B d t (ga) Sx Ix A 3.50 2.75 1.63 14 0.74 1.37 B 3.75 2.75 1.63 14 0.82 1.62 C 4.25 2.75 1.63 14 0.99 2.21 D 4.75 2.75 1.63 14 1.18 2.91 E 5.25 2.75 1.63 14 1.38 3.74 F 5.25 2.75 1.63 13 1.60 4.35 .. G 6.00 2.75 1.63 14 1.70 5.24 , GENERAL NOTES CONN. -U c 1 BRACE DIMENSIONS 14ga 1. This drawing shows standard details of the rack product line only. See engineer approved installation drawings (same Job number) for components used, special details, arrangement, and site specific information. 2. The installation drawings govem over this drawing. 3. MATERIAL Steel -ASTM A570 Grade 42 UNO Welding Electrodes -AWS E70 -XX (all welds single pass fillet welds designed at 50% stress levels) 4. Expansion Anchors shall be ICBO approved types. e.g. Hilti Kwik Bolt (ICBO RR #2156, 4627) ITW Ramset/Red Head JS type (ICBO RR#1372) Gunnebo Taper -Bolt Sup-R -Stud (ICBO RR #3219) Rawl-Stud (ICBO RR #4514) Embedment shall be minimum 5X Bolt Diameter. Other similar anchors may be used if ICBO approved. The anchor types, sizes, and embedments shown on the installation drawing govem over the sizes shown on this drawing. Special inspections are not required unless noted on the installation drawings. 5. Unless noted otherwise on the installation drawings, the allowable soil bearing value is 1.0 KSF. 1_ Min. 9/16" net throat per hook Hooks at 3" C-C DIMENSIONS AND PROPERTIES UNITS: INCHES UNO BEAM - COLUMN CONN. ( 5 `) 7 ga t - PETER ASSOCIA STR URAL E 1 5 -F NORTH P LENDAL ,CA 818- 9- i RAWINGAN ,COPYING BY 'WErSIGNE C OPT DE BUILDING ERA MUST SIG D t COLUMNS DIMENSIONS AND PROPERTIES NET SECTION - UNITS: INCHES UNO 118 CCTV of To( v 4 A Nob 2){ lggg rim , .nT CENTER Min. 3/8" Anchor (1 per post) STANDARD T=11 ga ti FRONT TYPICAL ELEVATIONS SEE INSTALLATION DRAWNGS FOR SITE SPECIFIC INFORMATION �mAP KWRA PRO ED SEP 0 9 1999 IBS ttO r €D BUILDING D BASE PLATES COMMON SIZES ONLY SEE INSTALLATION DRAWINGS FOR CUSTOM SIZES AND ANCHORAGE 7.01 Issue Date: REPUBLIC STORAGE RACKS STANDARD DETAILS pqq - 0.30 4 Type A B d t (ga) Sx Ix A 3.50 2.75 1.63 14 0.74 1.37 B 3.75 2.75 1.63 14 0.82 1.62 C 4.25 2.75 1.63 14 0.99 2.21 D 4.75 2.75 1.63 14 1.18 2.91 E 5.25 2.75 1.63 14 1.38 3.74 F 5.25 2.75 1.63 13 1.60 4.35 G 6.00 2.75 1.63 14 1.70 5.24 , Type W D (ga) As Sx nc ry A 3.00 1.63 14 0.44 0.47 1.26 0.63 B 3.00 1.63 13 0.51 0.54 1.26 0.62 C 3.00 3.00 14 0.63 0.75 1.33 1.10 D 3.00 3.00 13 0.74 0.87 1.32 1.09 E 3.00 3.00 12 0.86 1.00 1.32 1.08 F 3.00 3.00 10 1.08 1.22 1.30 1.06 G 4.00 3.00 14 0.71 1.08 1.74 1.12 H 4.00 3.00 12 0.83 1.25 1.74 1.12 ` J 4.00 3.00 10 1.21 1.78 1.71 1.09 , e.g. 19) ?d. m Iwn on the ,the 0.75 B BEAMS t DIMENSIONS AND PROPERTIES UNITS: INCHES UNO -1 _ ;� I. Min. 9/16" net throat per hook Hooks at 3" C-C BEAM - COLUMN CONN. 7 ga D COLUMNS DIMENSIONS AND PROPERTIES NET SECTION - UNITS: INCHES UNO I E„PIRES MAR 3 1 /DUO - 1 ASSOCIA S STR ' TURAL E NEE S 1 5 -F NORTH P.' FIC / GLENDAL , CA / 818- 9- FLAWING DE • Y ,C OPYING BY f' E' 0 ONLY. SIGNE COP . LY D FOR BUILDING ERM P CA D WING MUST SIG % AC OSS - BLOC 1/8 art ° ' itA i 2. 41999 e ,.u-r (:ENTER STANDARD T =11 ga L Min. 3/8" Anchor (1 per post) trI of TYPICAL ELEVATIONS SEE INSTALLATION DRAWINGS FOR SITE SPECIFIC INFORMATION UV Of TliNtUk ARMED SEP 0 9 1999 AS NO [EQ ci BASE PLATES COMMON SIZES ONLY SEE INSTALLATION DRAWINGS FOR CUSTOM SIZES AND ANCHORAGE Min. 1/2" Anchor (2 per post) FRONT SIDE 7.00" SEISMIC (t-318 ") Issue Date: August 18, 1999 Job # 3888 Drawing # Added Welds REPUBLIC STORAGE RACKS STANDARD DETAILS RP -1 pqq-o� DEPARTMENTS: B}'ifdt Division Public Works Pern Coo Yot. CDPO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D99 -0300 DATE: 8 -24 -99 PROJECT NAME: NATIONAL ENVELOPE XX Original. Plan. Submittal Response to Incomplete Letter # _ Response to Correction Letter # _ Revision # After Permit Is Issued DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route lin Structural Review Required APPROVALS OR CORRECTIONS: (ten days) Approved \PRROUTE DOC 5/99 Approved with Conditions 00 Fire Prevention >C-' 1 '11 Structural n Planning Division Permit Coordinator No further Review Required DUE DATE: 8-26-99 Complete Incomplete n Not Applicable Comments: DUE DATE 9-23-99 REVIEWER'S INITIALS: DATE: Not Approved (attach comments)( REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Fire Department Review Control #D99 -0300 (510) Dear Sir: City of Tukwila Fire Department Thomas P. Keefe, Fire Chief September 7, 1999 Re: National Envelope - 18296 Andover Park West The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. • (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57.•4404 • Fax (206) 5754439 Page number 2 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 2. No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.2) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 3. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Maintain a 3' clear space around the sprinkler John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 City of Tukwila Page number 3 Fire Department Thomas P. Keefe, Fire chief riser(s) for emergency access. (NFPA 13 4 -1.2) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. Hose racks must remain unobstructed to allow the rack to swing freely. (UFC 1001.7.3) 5. Sprinklers subject to mechanical injury shall be protected with listed guards. (NFPA 13- 2.2.7) 6. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. 7. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 8. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) 9. To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) In double row racks with heights of storage up to and John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 4 including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 231c 4 -3.1) Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 231C, 3 -2.3) 10. Smoke venting and curtain boards required by Table 81 -A of the 1997 edition of the Uniform Fire Code, shall be provided and installed per section 8102.7 and Table 81 -B of the 1997 edition of the Uniform Fire Code. 11. Racks designed for high -piled storage must comply with section 2207 of The Uniform Building Code. Please contact The Tukwila Building Department for details pertaining to design and installation standards. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7S•4404 • Fax (206) 5754439 Yours truly, cc: TFD file ncd City of Tukwila Fire Department 5 10 The Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fire Chief This review limited to speculative tenant space only special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 375-4404 • Fax (206) 575-4439 Detach And Display Certificate Detach And Display Ceniticaie, RE GISTERED CONST AS PROV CONT GENERAL PATR', CCOI EFFEC LA 44/01/20W . TIVE.-2,DATE PIANTA LIMITED PARTNERSHIP PO BOX TUKWILA 88028 WA 98/38-2028 13' END ELEVATI ❑N SCALE 1/2 "= 42"-- 16' FRONT ELEVATI ❑N 78" 130 1/2" 24 "— - EXISTING REPUBLIC RACK 10' 9' - 1/2" TYPICAL AISLE SEAL_ c B A REV REVISIONS 10' -10 1/2 BY 50' DATE CUSTOMER A SCALE 1/4"= DATE_ / - 21 -99 Q SC , STORAGE SYSTEMS INC. 0 \AL - \V APPROVALS TITLE PROJECT PLAN VIEW H REVIEWED and APPROVED PETER S. HIGGINS & ASSOCIATES CONSULTING STRUCTURAL ENGINEEPS 38 8u AUG 201999 JOB NUMBER HATE 9' -10 1/2 OP WHEN PLOTTED 24" X 36" 7745, 1ST AVE SOUTH SEATTLE, WA 98108 (206) 762 -569 FAX (206) 762 -6538 RECEIVED AUG PETERS. HIGGINS & ASSOC. 'c _ and plans does not authorial VW MolMlon of c r ordinal" "VW of cont,,._:cr's ed plane 11111111111Idaed. MIRES, RANI 3I 2000. APPROVED SEP 0 9 1999 As NO ILO DRAWN KEN WHEELER REVISION 15660 EAST HINSDALE DR ENGLEWOOD, CO 80112 (303) 690 -9591 FAX (303) 690 -4663 DRAWING NO. NATE129A THIS DRAWING AND THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF CONESCO STORAGE SYSTEMS INC. AND SHALL NOT BE USED OR DISCLOSED WITHOUT THE EXPRESS WRITTEN PERMISSION gOitRaCO, DRAWING SUBJECT TO RETURN UPON DEMAND. 499 2 II t999 EERWT CENTER 2 1 999 SHEET 1 SHT OF SHT