Loading...
HomeMy WebLinkAboutPermit D99-0308 - Centerplex C - Stairs)(et red Centerplex C City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 022320 -0051 Address: 331 ANDOVER PK E Suite No: Location: Category: AOFF Type: DEVPERM Zoning: TUC Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Contractor License No: Signature: Print Name: \1044C Permit No: Status: Issued: Expires: Occupancy: OFFICE UBC: 1997 Fire Protection: AUTO FIRE ALARM East: .0 West: .0 Streams: End Time: Fill: (206) 431 -3670 D99 -0308 ISSUED 09/10/1999 03/08/2000 Phone: Phone: (206)343 -0080 Phone: 206- 575 -1018 OCCUPANT CENTERPLEX C 331 ANDOVER PK E, UKWILA, WA 98188 OWNER BROADACRES PROPERTIES 1601 2ND AVE, SEATTLE WA 98101 CONTACT JOEY HASSON 331 ANDOVER PK E, TUKWILA, WA 98188 ** k************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REPLACE WOOD STAIRCASE WITH NEW STEEL STAIRCASE. ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 3,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * ** * * * * * * * * * * * * * *** TOTAL DEVELOPMENT PERMIT FEES: $ 141.86 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Size(in): .00 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performanc_of work. I am authorized to sign for and obtain this development permi Date: i0 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. - • : • 331 P.ritfti.)VEP Stfi te: e n ", • 1:JEVPER11 • Par # '022320-0()51 . • • :..' 7- ?...., • .., ,• , . .. .,••. . .• .. . . ., . . , . ' . ,• Per iii i .cOnil 1 t i on ,t.,..s.: :-. .... 2 .: : : • .. .. , • ' ' • " : ': , . . ' . : ; .. ; .. : . . . • . ' iV l iNC..i : .:010, 1 40S 'ifi i 1 1 . b'e ' i, : . made to the •':0 Faris On 1 ess : ;A 0 CA r 'by • t h&: :•:,':' . • ' .1.'. Elii.1 fileer. : ;'i n 0 the :1 i la ..:B 0•1t14:0 Cki !tf's..10/1 • : ' : • :' ' -''''.-, ' . . . . . 2 ,• . :A1 oermi t s . : insDeCt.i00-it0.6: 17) 1 ens .• s ha 1 1 be 'i : ' ' %i' ' a . ab te :at .the ,..,,V.Obi.:', or i cu . to the.fS"tet:•'.;..Of , ..' , .i, , ' • ' • , r . •, rUction,, :, 1.1 hs,e,...;;(14.5,cymeri ts :: re tci:';,be ;pia intaineOH-and a va i 1 ,.. : • - . , . 1 : . . . , . ' , „ . b•le : 'tint ill f,lii a:I''' fnp et. t:tOn ':', a P p r.OV1 I 1 ecitrii , Ca 1.• i te If. be :66 t - .ii . ii ned..'E'i.r hi. oii.4fithe 1 ,,iii,friq ton ,... . • ,, • % . . . • : • „.., . ” . • i ' tate : 0 i. ;;;iton of r and •• Industri 0 ,., a iici 13 si er:t4 1 • .. ,•. , , , - - • ;.• - ;wor k •• 31;: ,InSoeC t ed bir thlti -leen rli ''''I'''Aii ) •-''''''',' '-'-'',''''''',. • ;'• .: 4 •:,..: . i timb be • o.b In ed - t brOi.i911•:' ;t h ia S ea,tt.1 e •-:141:hci Cti•tin ty:s: tmen t Of . Pub 11 c :, 1 1 t P 1 umb i iii4 wiTT .be. ' • . `•••,''''• , - iv speCted4 - eticSc,.' ., ,I in 1,Ud i nix•:' all l • a o i'0•1 nig': ',.. •-,...., • '..:.; ::-.'. .. ,.• ':':•::::-,--• - , (295-47..2) .',' - • •-, : • - .---•-', . . ' '''' ,-. „ • • 5. ....,A ;: Mecha0 ! oaf -,WOr.lf. :.slie 1 t beiH'IOn"der separate . o- lilac. I S'itse d - 4';V:' , , - • .-- theiril tii of.'.., Tukw i la : ...-;•:::' - '':••'' • r :''. .- . „. , 4Tr.'donSt.i. to:',be.,...donein conformance with api '::'•.;%.. y . , .• . ; ' P. 1 an .. and ' r e t.j.i.r i r e men ts 6 the lInti*.oi-iii -Su f i n6 rode ( 1..9 4 • s.v -'- '.;:',,H. - ' :S:-• • Ed1- ) • l'aS • a mendeit. • tIni f oriii NeChan teal ." COde" (.199/ Edi;1-1.00•T'd':. , , r' nd ,.:::Wa .shi rf0 tOn:' e -E IT4y,' (1.91 , Ed i:t i oh ), . • • •'• ' -''-- ' .:'• .,'., ,,..:...: . ;-„••• titifii ty;•,: of Perm,t t. .14i0';') s's oi Of: a•--dei r i 1 •• o a pPr oiva:fl, of: .H F...,,' • ,p.1 , vs.p.ec i f, i (....a.tipns ;ant.1):,..computa ti,oris *1-te Si i - not be cop 7 : :•,;:. (fed to be :•a • p ei ifor..... or'' apOr oval . ,of ; any. * i 0 1 t 10 ru,'. of , 'Ofi, the'!.oi-Ov is Ions of the ':.-bil l Id i ni4. „Code Or of 'any ...,.:::- : :':•,.-,•-,.; other oiYclinanCe of, t he • 1 u r is d i et i Oh::.:•.....".No ,_•,p eViiil t p'f7,es Lim1n9 tb y. i A;i'veauthotiTity violate or•canceltheorOyttions of -',.. • i.: :: •• . . ,.• code , •;;Sha, 1 be valid . , ;NO t i f . y::‘: the C i ty Of fukili •1 a Bu i 13.11n E1 i ti .,i i On'.::p r - -i or to .--... . '.' .•i • ' 0 1 eie i nrn i any' concrete . Th i s • prOcedtir'e. 1 i.ii- add i t i on to • : i • e. 1.1 u i r Oen t s f tir,,:: .s p e c' ta 1 i n s p eCt. i on Status: ISSUED APo 1 ed 0812:6/1999 Issued: 09/10/1999 Pe nn • D9.9 Project Name/Tenant: Value of Construction:4 g Site Address: City State /Zip: 33 f? A vid olie t^ Po,e 4< E &‘7 744 Gtw /er 5 " g'/ /' Tax Parcel Number: 6 aA 3ao -et%7 - CS Property Owner: Jvv< ca. t{nct vt POD( Phone: )04 S75 /O / Street Address .3( Ai4de,re N City State /Z li �a r 1< L-i 7 7'4/ 't lti `I� /ip: ASS Fax #: 2Oi ,5" 7 5` / o A T Contractor: N OVIe. - f9w ttie v wal de g+ e - wvv k. Phone: Street Address: City State /Zip: Fax #: Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: w t ;Alke' is ! r^K[t�het 4 /ct / Mitt. vz j ut'wd AsSoG % y Phone: 206 6 23 / 'IV / Street Address: C,ity State /Zip: i 1 ctoy Al 14/ At46l00 Wi °Igco Fax #: Contact Person: .7c9ey lia S.501,1 Phone: 2a6 S c /a /5( Street Address: City State /Zi 331 /ivtc /eves f olo& C4,51- rat /w1 [( y �� $ Fax #: .206 5 75' -/0.2.9 Description of work to be done: r9place- W(x'd 57ir'V'cc(SC w!' 11 el e wi ?ee- / S'7/a r'b`cGf ic- Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 521 Office ❑ School /College /University ❑ Other Proposed use: El Retail ❑ Restaurant ❑ Multi family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ® Office in School /College /University ❑ Other Will there be a change of use? ❑ yes 2 no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 71 no Existing fire protection features: ❑ sprinklers ® automatic fire alarm ❑ none El other (specify) Building Square Feet: 7 ?b existing Area of Construction: (sq. ft.) 75 Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 51 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKW►LA Permit Center (_ 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THEFOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Dale app ion accepted: Date application expires: 0CX) Applical taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1/29/97 BUILDING WNER ORIZEE AGENT: Signature: I mm AUT V�, l� � ��, � i 9 ? �, a,� Phone: t 575_0 r7 Date: �4i )� �[(A . / Fax 'gi7 r rIJ - In �� Print name: c / T���i�x��� Address • 53. ( / Vvy n ( ,,, ,, t__: _ a r, ` 1, (1 /(2 0(7 City /State /Zip ltd Av r, ALL COMMERCIAUMULTMOMILY TENANT IMPROVEMENT h TERATION PERMIT A PPLICATIONS ST BE SUBMITTED WITH THE ' LOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTP1:RMIT.DOC 1 /29/97 ;77 9r ,V,47 -il' hit e4r'fiv%+=1" F":i1" ' „ 0 • h th•: k: 4 5 • *. 144h. hhvlh :'4:4:A•dr:k:47tA:1*:1; -' S k: 1h: 4: 4: 1•: k.: 4: 5 :': 14H 4:4*:4tl:t•4:5:1k:4•t1k:1•!ct -: CITY: ,OF .TU►:Wi. ,a OA Oq - ICZO8 r: 118I1 � . h.h*h * *h* **A AAhh:4hh h•*h•k* *k4k'•fi•k **4 k.1 * *h•k:l *4**'i•k:1*•:1k4* 1.RANSMIT Nunher: t 9U00124 Amount:. 141••.86 08/ 26/n9 13:49 ►?a.v nenti Method: CASH Notation: JOU THON POOL !in i t: fLi3 Permit ;too:: I9.9 --0308 Tvoet I?I:Vf'k:ltM DEVELOPMENT NERMI .Pfrcel 022320- 0Qri1 , Site Addre "s: 3'21 ANDOVER PY, E fo•tal 141., 36 1hI � Pavment 1.4L.€16 1ctt.,l ALL Pmts: 141.86 I3titlanoe: tt00 a:* s• k*'** fi'• 51doA** 4 * ***4d•***A•k4- *'54*iS44*•A•*4 44**k.**4*'4i *9t451h*•k***4*4 {account Code 000/323.100 000/343.830 000/386.904 Deecr i oti on BUILDING,- NflNRC8 PI.Ri'! CHI:CI( •- UONlt£5 STATE UU1:I.t)I C €URC•1NUriE t.'1 '.. :S• Amount 83.2 54.:11 • 4.50 6343 08/27 9717 TOTAL 141.86 ProjectQ er Type of Inspection: .. • 1 r‘vv.„1 Adt 1 — 1 ii,,,,ithiebr ‘y...t Date called: 6 , -.). Special instructions: Cfl IS -I-' 30 w\i.."P''''. i Vi Date wanted: Requester:3d hv‘ Phone Ce 1 i ,ant o 2,,...s .car).37 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 COMMENTS: 57 /A-0)g-4/cc / 44‹ /47 ti (4, //(r •o 5. 7 g ez,(76 4;1 INSPECTION RECORD Retain a copy with permit Appro r appli codes. - 14 4,441 4: '-44.44144,-4-,444 • 'f.et Y 'IN re (206)431-3670 orrections required prior to approval. D7 $47.00 REINSPECTION FEE RE UIRED. Prior to inspec ion, fee must be paid e at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Projecto -P , (/11 rp\eX Type of Inspection: 7. 1 Address: A t It, \ rha( P11- Date called: 5 - 20 - 00 Special instructions: eCt 11 1 30 yrtAS CON eoci 1-0 m fel- Date wanted: 5-2 / -00 a.m. 41 Requester: 1 301A vi Phone: ii 201°— 23223 ( / • INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 PERMIT NO. (206)431-3670 Ej Approved per applicable codes. WCorrections required prior to approval. COMMENTS: Date 5 - Ce) fp $47.00 REINSPECTION E REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: -�-" F11' a ;s are appr of Plan Check approval d that the pla ;sswns an d ap oi any ► ;r�cla ° � the violat 0 ( can' ize ec t ; ;��i?)ec not aothot pe• $ a � � Ors does d o f or dinan ce. / .�t r' code ovedpla C��a.tnt� Gaily oS a .1 /Al . Scale 1:125 / Area of Detail U ((`� i i`(�I �� R O E D (Y 1 EP 9 1999 COSION 00 of eirrn. ps pocc e r, R 4r 1st floor SEPARATE PERMIT REQUIRED FOR: ❑ MECHANICAL ❑ ELECTRICAL ❑ PLUMBING ❑ GAS PIPING CITY OF ThKWILA E'J LDING DIVISION Vig-o3ce Scale 1:45 ito r Iij APPROVED SEP 9 1999 I • • DIVISION r -- • 1 { * WELD�- 11.11 TO.2 S - . s. s 4 11' a 0•t 11 v.iI. !I L. r•Ml4. I 8 ] flRl. LJ:N61N 7i q SELD TI 4I.1 I w T, J E4.EVAZI1*i wiz W-Ite „7:71 t] YIELDED •,.. 1 •TJE !OWE — u' -- W AAL 5E0101.4 Ei SCALE A'•L•S' TREADS I EO LTS µ � L¢ MAO. SPA14 I • I . I :• $• sOLT1 }-•r 1 i 1344w WAN 1 DOLTS ` WOOL SPAN} ( - (I T • . • 3 DOTS I 1 i ; .i I i 22=i'MAL Sr A• N DOLTS E . R DON OIIWAL 44 r : e 43' 7'•2.44x 04. /t0 MAY. 2=0' MAI[. *5 FILL LENMMN� f I WEL1 TO 1C 1C 5.144.— •-... t 6 . Q a. - K 5ECT ALC R ■`I' 5TRU4TURAL T q* 4 4A/AR Wth. LYE t.e %:at ni LsWORM MAINS eat diet. LIvE LOAD 100 Cs, DEAD LOAD: I5i LI PER TREAD FouNDATIONS: EXTEND F00T4465 TO NOM UI4Pt3T1,WOEP SOIL JP 2COO fMF WARW. CAPACITY. A MIN1MWA Of r0 OELON Mao WADE. CONCRETE= r. -2600 P51. MM . OF 5 SACKS 9F CEMENT rut CisCIC tAP9 • A CCl1CRETe• MAIL If 61t SALLONS OF 1NATM PER 44 Le . SACK OF aEA AF.MM. IeCAgT LAw9 44S ANP TREADS CAST • IN A CE W)Es PLANT N -1125 LSD. EILOWA11214 It-843[5i uw• STEEL: sTRUCI ATM A•7 6.44.000 FS OR ASTAL k3i f.47.2001 F1FE COLUMN' ASTIR A•53 LRAM 'O• 4.33.000 ?St ALL NEWS SHALL 0E AY till OP SEATTLE CERTIWIEP WELDERS USING ASTM A•233 aAss e•so ELCtatopal. - ALL WELP5 SHALL • M3 %Le CONT. FILLET WELDS :1uIeSS OTHERWISE mow RE/JF0444•14 STEEL; ASIA. A i15 i&AOE 10 f..20,000 LSS - • - -- • LENERAL: - • -- xi♦ LNPEFORMEP 15AR RAIL DIfEKT WELD TO 4C eEND LIP 44TO TREADS 5711147101161, PRAWNS Al IlUIU 1W. 140f ?ART aF DNS 10.1M*I4 7114 sumo ID REVIEW M REWIRED 51 THE 5UILDM6 DEPARTMENT FOR ADESUATE LATERAL. AND TERTICA. Spiag rat ma STAIR LAPS 71A111AUM FISTANCs 5ETWEEW LANwIi5 mat. 1401 E7CEEI/ R tM tALLY. • I . LS■ 0- u3 sTAl2■17 VAS X TAIL4 SIKWAY atiNgiira. • "lux G23-'4" NAM ac14.NSTa 1s 1 wuw4Y A. 00 O • attOOATZ8 • SO PULL WELV W 4G r>1d.O.O7t MIN RAIL lDST E i•OG•MAX. I ME NWT SUL WIRT Ort'1r. £ W2-I • 4' WOE 2 lir FMK TOP OF TICIMP alkOk St? 1S* t tiC. ONO& IAM HE I 5 MIN: p ELEVATION SCALE ;'4o 44x 5.4 04 itzralk x L .' wu. PERIMETER, WSW TO G4 O'-O" TO 049" 115E 4x 4 j'U, @1 48' 1K D�% Mtn . 4 x 4/4, 11 J O'-O" 10 0 U4C4x4x4 (, >Ll fir• 1KBAP5 OK GR4 W CO' MAX. .4.O�o WELDED TO STRIN4E . 6 4K 54 1Y3 WELD TO 4G OEM 19 P INTO TREAD 2 MAX. -0' MAX. xr I0 MUN. an .r 5TRIN6ER SECTION SCALE 4'•I =0' . 7' ' ..5 " IYe 1G' 2=O MAX. e SECTION SCALE %.I:0. • !T /! T 'U - 3' MIN • I5 way TO OS eOND I INTO imp :90U6LA ' FIR - LARGN HEADER f� II 4 -%8 M.6 VARIES FOR 7THER SPECIE' 1 OF WOOD 4 - %M. '. NO.OF BOLTS VAKIES FOR OTHER Specie OF WOO VP MODUT RAIL WORT • y 24;1)44,06'e W /4*' x VAK 1V�I.VW ¶0 Iifr'TMAW IEI4 4 6rUD5 04" 54 x d-b' wWw M. To It. PIM *Ill 11115E 5TRINbIEK IZ' I 3 3 -I 4" SECTION II 56ALE 34 =I.0' 6601101.1 tr,Z7si ruIY,FED 4LaT5 a 1RFAD WELDI114 SAO LWGHW FROM 14 OUT 51E11. CODE ENERAL STRUCTURAL WOTE5 THE SEATTLE BUILDING CODE (5$CJOK THE UNIFORM BUILDING GORE LIVE LOAD: 100 P5F DEAD LOAD: 156 LB. PER 48 . 14(, L°.' PEK 34'TREAD CONCRETE Pc. 2500 P5.1. MN. OF 5'h 5ACK5 OF CEMENT PER CUBIC YARD OF CONCRETE. MAX. OF 6 GALLONS OF WATER PER 94 L8- SALK OF CEMENT. PRECAST "TK.FJ175 444T W A GEKfiroE, r .rr fc.' I I25 P5.1. STRUCTURAL STEEL: 45.T•M. A-54 fs. r4600 P5I. nrs COLUMNS ASTM k34 OR A-53 GRADE '6' =56 000 PS.I. ALL WELDS SHAW OE 1,Y GnY OF 4EA?TI.E ALA W�L tai S HAW, 17E ' �GO�rr FlIAXT IM1,17& UUt, KODEs O(HFRW15E NOTED REINFORCIKIG STEEL: A.S.T.M. A -6I5 GRADE 40 Fs= 20,000 PS1 FOR TREAD& Pn6A5' N A GEICTIrIED PL,At4T. STRUCTURAL FRAMING AT BUILDIN6 I5 MOT A PART',FINK MO M& AMP 1551115.1501 TO REVIEW AS REQUIRED BY THE BUILDING DEPARTMENT FOR ADEQUATE LATERAL AND VERTICAL SUPPORT FOR THE STAIR LOADS. RAMON STAIR STRINGER tti FOOTING POE WIC MTN ADEN CANTILEVER TREADS 14040 INTILIMPUMN 5 WTol MATT WA3M�MrtiY HARVEY R. D000 • ASSOCIATES awns wn+.a+a. I'3x MIN RAIL We 40'04. MAx. +7 FULL PER iETeir.. WEt.P TO 46 5DE MOUNT WAIL IIISERr IrZ'x3'x IC W2-49's 4' HEAPED Lo !L Xe FRUI TO OF TRW r'kT: ts,t‘IUS1 °1\1 ,. L�RGU� H APPER1 • Q 3 MIN: ELEVATION SCALE % %I=0' �D FULL ? E4M WELD TO 64 G4s5.4x Kelm. ® 1 r O:0" TO V0" USE 4x 4,3'Ur 9413. TICEADS OKGA 4%4'i, Up 0=0' TO 0.0' WM 4x4x4'w x' 1R'EAPS OK GR4'146 1 \ G4x5.4x0�o' WELDED TO STRINGED it, WOW TO 46 BEND .UP INTO TREAD 4-O" MAX. tie 2 =0" MAX. 2 MAX. STRINGER 5ELTION 5CALE %' =I =O' I0' MIN. Ok. 13" 7" .3 Vz' • I IG' SECTION 5CALE TKINGER :DOUGLAS FIR - LARLH HEADER --3" MIN REINFORGIIJG 5TEEL: GENERAL: traif maw 6L716 WITS TIP WSUALI4 6.4114 I)IGNEG FRON 14 •• BUT 5101. ASTM. A-6I5 GR IN A GEKTIrIED STRUCTURAL Fit AND I55UDJCG'T TC DEPARTMENT Fd FOR THE 5TAIR RE w June 9, 2000 Joey Hasson 331 Andover Park E Tukwila Wa 98188 RE: Permit Status'D990301 331 Andover Park E Dear Mr. Hasson: Sincerely, C City of Tukwila Bill Rambo Permit Technician Xc: Permit File No. D99 -0308 Duane Griffin, Building Official Department of Community Development Steve Lancaster, Director In reviewing our current permit files, it appears that your permit to replace a wood staircase with a steel staircase, issued on September 10, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 433 -7165 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Steven M Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206.431.3665 Complete 1 [4 Comments: U'RROUTE.DOC 5/99 .r�F 14 .• .t .,.-9•:�r.. " „'c. x ",; , n� : 'r' ,- ;enx•. .g;..r ...Y.• •aye ,`". �4' 7r, ,,it:+<;tr ":'t ?'.^`t;T... , • .... ,. n....t.. ..,. S:b'r.,..;dP, .. N..w. ._. .._4"... . +'!.F_',u....:N +. t...r . ... Pexvy Cco �t/1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D99 -0308 DATE: 8 -26 -99 PROJECT NAME: CENTERPLEX BLDG. C - STAIRCASE XX Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # Revision # _ After Permit Is Issued DEPARTMENTS: Building AR Division . W Public Lana "VA R N 0 Fire Prevention e z-qy Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES /THURS ROUTING: Please Route 2 Structural Review Required Approved ri Approved with Conditions Plan in Division IA Permit Coordinator DUE DATE: 8 -31 -99 Not Applicable No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE 9-28-99 CORRECTION DETERMINATION: DUE DATE Approved C Approved with Conditions ri Not Approved (attach comments) Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: REVIEWER'S INITIALS: DATE: AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON ) ) ) COUNTY OF KING Cede l 8x 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. 13 , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform co `ruction work. AFFCONT.DOC 5/29/96 CITY OF TUI� 'ILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 SS. , states as follows: Signed and sworn to before me this � residing at day of CLUVAAZ H -4 RECEIVED CITY OF TUKWILA L. PERMIT CENTER , 19_9_9_. NOTARY P f IC i and for the State of Washington, '1' I PXe1L. County. Name as commissioned: L My commission expires: 6-Q 6 Efloece 18.27.090 Exemptions. This chapter s -1 I not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when perforrhed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT.DOC 5/29/96 of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors highway projects who have been prequalified as'rec aired by chapter 13 of the Laws of 1961, RCW 47.28,070 With ■ the department of transportation to' perform highway construction, reconstruction; or maintenance work.