Loading...
HomeMy WebLinkAboutPermit D99-0390 - Boeing - IAM - DoorBoeing /IAM City of Tukwila � Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 295490 -0425 Address: 6840 FORT DENT WY Suite No: Location: Category: AOFF Type: DEVPERM Zoning: RCMU Const Type: Gas /Elec.: Units: 000 Setbacks: North: Water: TUKWILA Wetlands: Contractor License No: GENERCCO27MA OCCUPANT BOEING /IAM Phone: 6840 SOUTHCENTER BL, TUKWILA WA 98188 OWNER RADOVICH DEVELOPMENT CO Phone: 425- 454 -6060 2000 124 AV NE, B -103, BELLEVUE, WA 98005 98005 CONTACT MICHAEL SULLIVAN Phone: 253 -657 -6427 PO BOX 3707 M/C 3U -EH, SEATTLE, WA 98124 CONTRACTOR GENERAL CONSTRUCTION COMPANY Phone: 206.368.6348 PO BOX 24506, SEATTLE, WA 98124 ****************************************************** * * * * * * * * * * * * * *** * * * ** * ** * * * * ** Permit Description: ADD DOOR IN HALLWAY. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 2,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 118.76 ***************************************************** * * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** Permit Center Authorized Signature: Print Name: t'llC/l dZ- Saw v/kJ DEVELOPMENT PERMIT Permit No: Status: Issued: Expires: Occupancy: OFFICE UBC: 1997 Fire Protection: SPRINKLERS .0 South: .0 East: .0 West: .0 Sewer: TUKWILA Slopes: N Streams: (206) 431 -3670 D99 -0390 ISSUED 11/16/1999 05/14/2000 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development perm t. Signature:_A 4 4 // Date: / / — /( - This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. t. 'C ikOdgess 6840 FORT DENT WY Permit No: D99-030 Sui to Tenan.0 Status.: ISSUED '. Type: DEVPERM Appl i ed 10/22/1999 Parcel ., #: 295490-0425 Issued 11/1641999 AAA******' A**** A*** k*A****** * *•AA *. * * *•A * ** * * * *'A **** *•A * ** fit * * ** ** * ** ** **A * * * *k* :. Permit Conditidns: 1. iNo changes wi 11 be made to the plans unless approved by the Engineer. and the Tut,wi la Building Di:vision 2 All construction to be done 'i conformance with approved plans: and requirements of the_ Uniform f3ui.=l d i ng Code (1997 Edition) as amended; Uniform Mechanical Code .(1997. Edition) , and Washington State Energy Code (1997 Edition) Al.l Perm its ;irispe?ction' :records, and approved plans shall be: :available at `the ,jib 'Site prior to the start of any coh struct i an; :-` These `documents are to be 'maintained , and `ava i l -- :able until final 'i`nspection:.'approval is granted 4 'Val idi °ty .of Permit, - The issuance, of a per mi't: or approval .of p l ans spec,i f i cat ions , and computations shall` not .6e _con strue,d to; a permit` for or an.''approva1 of any y violation of a n r . of the provisions of the.' i 1 d i n g code or ''of any other,`or dirance. of the.'...juri,sdiction No permit presuminq;to g ive ; authority to .vio.late or cancel . the provisions of :.this ,code,, sha 1 l be; TUKWILA, Project Name/Tenant: ADD noon / 8oEIN6 — 1414 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel .. Office ❑ School /College /University ❑ Other Value of Construction: .i Z000 Site Address: 6.S40 sou 7l4eeNTh. Se- fl .WiL4 City State /Zip: Tax Parcel Number: 24S¢90 o423 Property Owner: ?AoovicH 0EvEGA°rl &/l G Building Square Feet: Ia 0 , Q2 6. existing Phone: 4.2s - 6066) Street Address: _ City State /Zip: 2000 124 Auc Ail # .8-lo.2 3Eu.Evue W,4 oocr Fax #: Contractor: Phone: Street Address: City State /Zip: Fax #: Architect: BOL" / /J6 — j oB $E2Li&J Phone: LT3 - 6s7 - 6 902 Street Address: City State /Zip: P o Qox; .3767 HA 3u -eil ,E u/4 g8t24 Fax #: 23 3 - 657 - 6 6// Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: P1 w L Su cu V4,..1 Phone: 2.S3 6s 4.4-27 Street Address: City State /Zip: P 0 QOx 2707 t1.. 3u -CH 864-T7W wR gg /2 4 Fax #: 2v3 6S7 - G6 // Description of work to be done: ADO 0002 ,,) »ALLw4K Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel .. Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse C3 Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel p Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes pi no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes no Existing fire protection features: 71 sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: Ia 0 , Q2 6. existing Area of Construction: (sq. ft.) 5O Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TL" <WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST -FOR PUBLIC WORKS;SITEICIVIL PLAN REVIEW OF (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control Zone ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only ❑ Hauling gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date a�ph - accepted: 141 PLEASE SIGN BACK OF APPLICATION FORM C[PERMIT.DOC 1/29/97 Date ap cello 1 Appl o t Wats) BUILDING OWNE `, • R AUTHORIZED AGENT :: Signature: // Date: U - Z Z — Vi Print nam: e ":,.. „1�1f�ri'�)�rL uccit �.,, �r �► . Ph ,Phone .. z..: - ; G� 3 �: 7 !�¢ . Fax # .. s;�► 761/ ' Address I' 0 t c)� • S ?D7 r1ic• 3m ,15/1 Cit /Slate /Zi ` "' y p eyi. TLc: tA.44. qsizzp ALL COMMERCIAL /MULTI - FAMILY TENANT IMPROVEMENT /ALTERATION PERMIT APPLICATIONS MUS SUBMITTED WITH THE FOLL I NG: ➢ A LL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, ST*UCT(JFICL'iNGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ in Complete Legal Description ❑ El Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: if adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ in SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent if the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMI'T.DOC 1/29/97 IT:F.P okrvt-wis.77, 4740;TAIMPfiryrst • .• , . • ' .• , ...-;',. -;,',..: '., :: ',..: : ..:. , •'. . , '.;`,i.. '', ,., . . ' . - . 1; •§ *. 1 ' . . ": ' . 41..4 4. :/i4c 4. * 4; It' :A * 4 "A"A"k * A * qti .k. * it ..A. A' * ic * * -A * 4 0 A: * 0 A * A trr ..4 * A * 47 * ..,ye ..1* 1E * A '.4. , - . Ci ; 1 ":6 1 it: Al ;;,',:. f-; ; ••.'• . :;•. .....-• ' • ) , 1 - : ,. • ,‘, ',:: : ' ' ._. ' T• R 6 o. s iq):, 1 4Lq '.. - i),.'.:(4:,:i, A ..,i; 4,... 4, •k : k 4* I, ,..k. .. # ; ...,k Nle 4 A .14., *.#,.. * A : Ill * A -ir * .L: * 74 * it * * * •,, 44-45 10—it le .* it T R'iNSilT, I.: NO6 ti.• ti ••: 9S.U.0 •171:,•,,Anto um t : ••: ,l : • , -.' . 11J :. 7 (.3•. I 01';'.2,./9.. ' 1•3.t: 52. •:' 6. •14 :•'•-••C Wit IC 1 14 a .. Ot.i on r S li A I( LT GER VI CF::6 • 1 il i : • ., • - 7. , . Hei 1)92-0390H; ::Tvp'et 1)g9PE1U1 , 1)1:VELOPME:tri: PERMIT S i..te'ASAcillress: 6849',S01.1THCENTER 01.. • :: .. '•-•• ,., • •.• . . •, r ':'.:•.:..: ..1 '...., „ ; ::: .; • '.." :'„ :, s• • : . ••lotal .Fel::,..:, ; : • :11.8 : 76., THisi:f) Et'..v miirit '• H . ''.: .11 8 . 76 : T cs t a I ALL. P,i(ii •.• , 11.8.76 .. '' -•'• , : : ..• .. - .. " - ' . 1) al anpe :: : . " .• ,...0 0 ,k4:1,444,1*>+4r4;44.A.h A4*.* .. . . .10 ion: '1 ' . (rnouni; 000/322.40Q . BUILDING 0.., 25 0/34 830: PLAN CHECK: 000/.38.944 : - SI AKE MUILDINO SURCHARGE - .. 41.50' 0202 10/25 9710 TOTAL 118.76 Project: Type of Ins . _ - on: Addr:ss: Date cal '*`I , r ai Special instructions. te wanted: am. Requester: _ (�` . t � Phone: , / INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ' 'v PERMIT NO. PERMIT NO. 3670 Approved per applicable codes. ❑ Corrections required prior to approval. El $47.00 REINSPECTION IEF Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: )Qe` + P�' AA 1 ; of Mr� von kk A res : /� obi)/ ( 40 cpc+ Di l‘i Date c � j lled e'� Q(] pecial instru Lions: t M ` h nP i Date wanted: a.m) �� I. -9.. m. Requester: Q ! P / h � one �j [� / !► `' / {"� f +� /� X047 llO A4!LP '"')1 ! 1A1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 Approved per applicable codes. KCorrections required prior to approval: COMMENTS:' 1/244. t^p, �, fK- k�f 17 5, ---- Inspector: Date: /a --2..7 4, El $47.00 REINSPECTION E REQU ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Prc t: ; el) L Type o InspeCtion: , c(44 027 .,. • t i_ wr Dal, ailed: 9, ----- Sp irauctio7, ., & _ . Date wanted: 1 , 7 4 0 / 9 49 a.m Request . ‘ ,4,2,. Phone; INSPECTION NO. 'INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 .• Approved per applicable codes. Corrections required prior to approv t COMMENTS: .....) Inspector: t2.4,0 .4 Date 12^'V79 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: City of Tukwila Fire Department Project Name rt P,riN Address L‘)9 Feel ck .tC Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature INALAPP.FRM TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No.` t —0 39a Suite # 1 al 1 1Cr\ Date Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 57$4439 a!i •'.r r•s-� art:.u�•.. .a�,y -nt: =- •�sv,YVe, re -rx.•i ^n'': {+d+4'i?':hd•.57 � v Y a � a.r r ...y . i k'i S '� ;:t : 3 . - "i: r,r >.�.: :;t.ti 1 ,,: � �ro�,C� . T. ...a, n r r r � 4� ";�1�;!!^yr ;;�t`r �!f. ,M; t .F'S!:,'!" ;!C' . t;,. 15•H i... e 6:' �scit:. �..•, n: ti",` r1n. L>•. �i': �t�i..,-.... i.,,. �I.:: tlLr. t; � k+: It ^.<A " � • �';.`�i.�tib..e "i:.... e,....:•.{ �. �. a, 4». r. �..t ��, J.;• h:l dt:: a. a.....,,- 1�4..... �..,,,.. r,. �..... �.,...... �., 14..J.. �..�,t�3�:24t _.t',�.,';. �";r t .. DEPARTMENTS: Gj BuilA Division Fire Prevention p'2fr 9 tC ∎ D'Ar4 Pu Iks Structural DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditions REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 ' IVIT.Y NUMBER: D99 -0390 DATE: 10 -22 -99 PROJECT NAME: BOEING - IAM Xx Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # . After Permit Is Issued tin • ' t Card • PL N REVI W /ROUTING CORRECTION DETERMINATION: DUE DATE Approved ❑ Approved with Conditions Planning Division Per it Coordinator IYl DUE DATE: 10 -26 -99 Not Applicable ❑ TUES /THURS ROUT NG: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE 11-18-99 Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: Not Approved (attach comments) DATE: City of Tukwila Fire Department • Fire Department Review. Control # D99 -0390 Re: T.I. at Boeing Company IAM - 6840 Southcenter Blvd. Dear Sir: John W. Rants, Mayor Thomas P. Keefe, Fire Chief The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection' was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2• Thomas P. Keefe, Fi►e Chief halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 3 required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Thomas P. Keefe, Fire Chief Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than.four feet wide. (NFPA 13- 4- 4.1.3.2.1) 7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. John W. Rants, Mayor 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 4 Thomas P. Keefe, The Chief 9. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 John W. Rants, Mayor Page number 5 City of Tukwila John W. Rants, Ma; Fire Department . Thomas P. Keefe, The Cf requirements' based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 14. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Headquarters Station: 444 Andover Park East • Tukwila Washington 98188 • Phone. (206) 57S -4404 • Fax (206) 575 4 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 John 14 Rants Mayor 77zomas P. Keefe, Rre Chief Poet -it Fax Note 7671 Dd I1i(La 14e 7- From, E C. Co. Q `` To )1A t (s:-t S u 4_1— ■ %4 CoJDept. Phone M -1_ iv 1t1 Phone a `Ss. - 5.433 Fair 7 .- 1 _ G 41 i Fax M ( S gy _ 1 ttUV71 NOV-04-1999 1:30 ( ; )neral Construction Co 17c1urh And Ai+plap L:crti!'icutc Detach AhU Utypla) Conifn.41%. REGISTERED AS PROVIDED BY LAW AS CO1+1ST CONY GENERAL REGIST.. # :,EXP. DATE CGO1 . OENERCCO27MA:10 /01/2000. 'EFFECTIVE. DATE.. 07/01/1998 GENERAL CONSTRUCTION ONSTRUCTION. COMPANY PG BOX 24506: ' • SEATTLE WA • 98124 - 0506 Signature Issued by DEPARTMENT OF., LABOR AND INDUST 3603941445 P.02/02 Please Remove And Sign kienlification Card Before Placing In Billfold • • rM14124 4 (ers7) DEPARTMENT OF LABOR AND TNDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL+ • • REGIST.:# •...EXP. DATE CC01' . GENER00027MA•'10 / Oil 2000 EFFECTIVE ..„. 07/01/19 GENERAL CONSTRUCTION COMPANY. PO BOX 24506 SEATTLE WA 98124 -0506 TOTAL P.02 n ; K i 'E)21 t T IJ I) o 9G BUILDING oq- 7-68 .03? CODE REVIEW OF THE NEW DOOR INSTALLATION Please see the attached floor plan for area designations Applicable code sections Occupant loads Code review Table 10 -A Minimum egress requirements Section 1004.2.2 Travel through intervening rooms Exception 2. Where access to only one exit is required from a space under consideration, exit access may occur through an adjoining or intervening room, which provides direct access to an exit. Exception 3. Rooms with a cumulative occupant load of less than 10 may access through more than one intervening room. Exception 4. Where access to more than one exit is required from a space under consideration, such spaces may access one required exit through an adjoining or intervening room, which in turn provides direct access to an exit or to a corridor that provides direct access to an exit. All other required access to exits shall be directly from the space under consideration to an exit or to a corridor that provides direct access to an exit. Section 1004.3.3 Hallways Section 1004.3.3.1 For exit design purposes, hallways shall be considered as intervening rooms. Section 1004.3.3.3 Hallways are not required to be of fire- resistive construction unless a building element of the hallway is required to be of fire - resistive construction by some other provision of this code. ctn OF /vco Area1- F J/1 N 1 8 20 00 single offices 792sf /100 = 8 PE e FNTER Area 2 - open office space 911sf /100 = 10 Area 3 — open office space 802sf /100 = 9 Subtotal = 27 — less than 30 - only one exit required Area 4 — single offices 362sf/l00 = 4 Area 5 — conference room 1103/15 = 74 — more than 50 - two exits required Exits required Office spaces. The single offices, areas (I) and (4) do not have a occupancy greater than 10 and may exit through two intervening rooms. Area (2) has an occupancy of 10 and may only exit through one intervening room. Office areas (I) and (3) together may only exit through one intervening room. Conference room. Two exits are required. One of the exits may be through an intervening room the other must exit directly to a rated corridor bqqo3qo F4GL 1 OF REF- Pc. ie,i i - R G Exits provided . Office spaces. The combined offices areas (1) and (3) may exit either to the west is directly into a rated corridor, or through the intervening room formed by the new door (6). Office area (2) may exit by either through office area (3) as an intervening room, or through area (6) as an intervening room. Office areas (4) can exit through area (6) as an intervening room. Conference room. The exit to the south opens directly to a rated corridor. The exit to the west goes into the intervening room (6), and then to a rated corridor. Construction requirements for area (6) 1. Area (6) is an intervening room for exits from both the offices and conference room. 2. Area (6) is not required to be a corridor, but as an exit it is a hall. Section 1004.3.3.1 states that for exit - access purposes that halls shall be considered intervening rooms. 3. Halls are not required to rated. Other I. The building has an automatic sprinkler system throughout. 2 Area (6) has all of the correct exit signs. DAR- 0 390 PO-GE 2 oP NORTHEAST QUADRANT FIRST FLOOR DOOR AND RELITE UNDER CODE REVIEW 1 /a =r -o 0 5 10 15 20 FEET 2E F i kJc) . I) — 90 P,oE 3oF3 INDEX OF DRAWINGS INCLUDED IN SET DRAWING NO. SHEET NO. DRAWING TITLE REV DATE ARCHITECTURAL • 7.68 -G1 G1 COVER SHEET /INDEX k 10.11.99 0 7.68 -2A1OR 2A1OR WEST SECOND FLOOR PLAN - 10.07.98 0 7.68- 2A280R 2A280R WEST SEC. FLR. REFLECTED CEILING - 10.07.98 0 7.68 -A501R A501R INTERIOR ELEVATIONS & DETAILS - 10.07.98 • 7.68 -1A10 1A11 EAST FIRST FLOOR PLAN B 10.11.96 0 7.68 -2A10 2A10 WEST SECOND FLOOR PLAN F 10.20,98 0 7.68 -2A11 2A11 EAST SECOND FLOOR PLAN B 1.24.94 0 7.68 -A200 A200 PARTITION & WALL TYPES A 7.15.92 0 7.68 -1A281 1A281 EAST SEC. FLR. REFLECTED CEILING B 10.07.98 0 7.68 -2A280 2A280 EAST SEC. FLR. REFLECTED CEILING B 10.07.98 0 7.68 -2A281 2A281 EAST SEC. FLR. REFLECTED CEILING B 1.24.94 • 7.68 -A350 A350 SCHEDULES E 10.11.99 0 7.68 -A500 A500 MISC. DOOR DETAILS G 10.07.98 0 7.68 -A501 A501 INTERIOR ELEVATIONS & DETAILS E 10.07.98 O 7.68 -A502 A502 INTERIOR DETAILS A 7.15.92 • 7.68 -A503 A503 DETAILS C 10.11.99 MECHANICAL 0 7.68 -M1 M1 HVAC LEGEND C 10.07.98 0 7.68 -M2 M2 PIPING LEGEND A 7.15.92 0 7.68 -M3 M3 EQUIPMENT SCHEDULE C 10.07.98 0 7.68 -2M1OR 2M1OR HVAC DEMOLITION - SECOND FLOOR WEST B 1.24.94 0 7.68 -2M10 2M10 HVAC - SECOND FLOOR WEST D 10.07.98 0 7.68 -2M11R 2M11R HVAC DEMOLITION - SECOND FLOOR EAST B 1.24.94 0 7.68 -2M11 2M11 HVAC - SECOND FLOOR EAST B 1.24.94 0 7.68 -2M110 2M110 PLUMBING - SECOND FLOOR WEST A 7.15.92 0 7.68 -2M111 2M111 PLUMBING- SECOND FLOOR EAST A 7.15.92 0 7.68 -M260 M260 FIRE PROTECTION - NOTES,SECTIONS ,Sc DETAILS ORIG 7.31.91 0 7.68 -2M261 2M261 FIRE PROTECTION - SECOND FLOOR PIPING PLAN ORIG 7.31.91 0 7.68 -2M262 2M262 FIRE PROTECTION -SEC. FLR. REFLECTED CEIL'G ORIG 7.31.91 0 7.68 -M310 M310 TEMPERATURE CONTROLS A 7.15.92 0 7.68 -M500 M500 SECTIONS & DETAILS A 7.15.92 ELECTRICAL 0 7.68 -E1 El SYMBOLS,ABBREVIATIONS AND INDEX B 02.06.95 0 7.68 -2E1OR 2E1OR 'LIGHTING - SECOND FLOOR WEST E 10.07.98 Q 7.68 -2E10 2E10 LIGHTING - SECOND FLOOR WEST E 10.07.98 0 7.68 -2E11R 2E11R LIGHTING - SECOND FLOOR EAST B 1.24.94 0 7.68 -2E11 2E11 LIGHTING- SECOND FLOOR EAST B 1.24.94 0 7.68 -1 E61 R 1E6 R 1E61 208Y/120 VOLT POWER -FIRST FLOOR EAST 208Y/120 VOLT POWER -FIRST FLOOR EAST A A 02.06.95 02.06.95 0 7.68 -1E61 0 7.68 -2E6OR 2E60R 2080/120 VOLT POWER- SECOND FLOOR WEST E 10.07.98 O 7.68 -2E60 2E60 208Y/120 VOLT POWER- SECOND FLOOR WEST E 10.07.98 0 7.68 -2E61R 2E6 1R 208Y/120 VOLT POWER- SECOND FLOOR EAST B 1.24.94 0 7.68 -2E61 2E61 208Y/120 VOLT POWER- SECOND FLOOR EAST B 1.24.94 0 7.68 -2E110 2E110 480Y/277 VOLT POWER- SECOND FLOOR WEST C 10.07.98 0 7.68 -2E111 2E111 2E1108 480Y/277 VOLT POWER- SECOND FLOOR EAST 480Y/277 VOLT POWER- SECOND FLOOR WEST A A 7.15.92 7.15.92 0 7.68- 2E11OR 0 7.68- 2E111R 2E111R 480Y/277 VOLT POWER- SECOND FLOOR EAST A 7.15.92 0 7.68 -2E210 2E210 SECURITY- SECOND FLOOR WEST A 7.15.92 0 7.68 -2E260 2E260 FIRE PROTECTION - SECOND FLOOR WEST C 10.07.98 0 7.68 -2E261 2E261 FIRE PROTECTION - SECOND FLOOR EAST A 7.15.92 O 7.68 -2E360 2E360 TELECOMMUNICATIONS - SECOND FLOOR WEST D 1.24.94 0 7.68 -2E361 2E361 TELECOMMUNICATIONS - SECOND FLOOR EAST A 7.15.92 0 7.68 -E500 E500 DETAILS- LIGHTING D 10.07.98 0 7.68 -E501 E501 DETAILS -POWER A 1.24.94 BUILDING 7 -68.2 PROJECT SITE. NO SCALE REVISION RECORD DRAWING ENLARGE CONFERENCE ROOM REARRANGE QTTP CLASSROOM ( 000010) MOVE DOOR ( #J00816) ENCLOSE HALLWAY ( #K00899) TO TACOMA JP LMW JSW LMW RB RBB APPROVED GC CL MW LF MW BC MW BC KENT AUBURN ALGONA DATE 7.15.92 1.24.94 02.06.95 9.29.95 9.29.96 DEKT I C rc D 1 8 KING CO. PIERCE CO. SAM G 6840 SOUTHCENTER BLVD. TUKWILA, WASHINGTON 98188 TO SEA -TAC AIRPORT 4 MILES TO TACOMA 25 MILES REVISION NO SCALE RELOCATE WALL ( #L00060 -100) NEW OFFICES /CONF. RM. ( #L00622) BUILD OFFICES ( #M04061) ADD RELITE ADD DOOR ( #NO2125 -000) RBB RBB RBB RBB RBB BY APPROVED REM REM JTM JTM PSV DATE 02.06.97 02.14.97 10.07.98 10.22.98 10.11.99 B®E®AW FACILITIES DEPARTMENT 0 p NO SCALE SITE PLAN FR, TILE COPY flan Choc: .:f omissions I amnia*. Os viola A or Crowns aW . coot . ; ? AAA asraillmodg ed. VV 9 E ✓ I I- ( - - 7 9 0c ....a ISSUE LEGEND NOT YET ISSUED O PREVIOUSLY ISSUED, NOT IN THIS ISSUE • IN THIS ISSUE ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98007 1 1 ❑ EVERETT, WA. 98201 -� 2855 UI ' OF II?UI'rIIf P.I.I" I)'11'0 ❑ KENT, WA. 98031 • TUKWILA, WA. 98188 ❑ RENTON, WA. 98055 �'����� �� �:nslio:GYCA ❑ SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED AY DEPT. DATE 7.68 -E502 CODE DATA LAND USE ZONE: 02 (GENERAL OFFICE) BUILDING CODE: 1997 UBC OCCUPANCY GROUP: B CONSTRUCTION TYPE: III, 1 HR.- SPRINKLERED SEISMIC ZONE 3 EXISTING PARKING STALLS: 387 TENENT AREA OF FLOOR: 16,871 SF GROSS AREA OF BUILDING: 60,926 SF THIS PROPOSED T.I. 1870 SF qq MitIO GP CULTUM MP735LEY 5.6.91 DRAWING INDEX /CODE DATA E502 DETAILS -LAN & TELECOMMUNICATIONS TITLE DTRLE BLDG. 7 -68.2 COL LOTS 1 AND 2 OF SHORT PLAT NO. 79 -7 -55 ACCORDING TO SHORT PLAT SURVEY RECORDED UNDER KING COUNTY RECORDING NO. 7908210370; SITUATE IN THE CITY OF TUKWILA,COUNTY OF KING,STATE OF WASHINGTON. PROJECT SUMMARY NEW OFFICES AND RECONFIGURED CONF. ROOM. D941- 0-310 LEGAL DESCRIPTION COVER SHEET /INDEX ARCHITECTURAL MASTER C 02.06.95 TUKWILA BE &C ENGINEERS LAST RE`ASION SHEET G1 JOB NO. DWO NO 91090 7,68 -G1 K SYMBOL 10.11 .99 DATE 190G001 X BERL/10.14.99/14:16 EAST FIRST FLOOR PLAN CONFERENCE CONFERENCE 1114 REMOVE EXISTING DOOR CLOSER. FILL HOLES IN DOOR AND FRAME WITH MATCHING PUTTY. DELIVER CLOSER TO CONSTRUCTION MANAGEMENT. NEW DOOR AND RELITE. SEE DETAIL 10 ON SHEET A503. FOR HARDWARE SEE SHEET A350 NEW DEMOUNTABLE WALL. FINISH TO MATCH ADJACENT WALLS. EXISTING CLOSER TO BE RELOCATED TO NEW DOOR. t:ec 0390 LEGEND OFFICE K21A5> GENERAL NOTES EXISTING CONSTRUCTION FIRE RATED G.W.B. PARTITION DEMOUNTABLE PARTITION ROOM NUMBER DOOR NUMBER 1. ALL DIMENSIONS TO FACE OF STUDS,FACE OF EXISTING FINISH AND CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED. 2. ALL DEMOUNTABLE PARTITIONS AND G.W.B. PARTITIONS SHALL BE CENTERED ON COLUMN LINES, WINDOW MULLIONS OR COLUMN ENCLOSURES UNLESS OTHERWISE NOTED. > REMOVE EXISTING DEMOUNTABLE PARTITION WALL COMPLETE. SAVE PANELS FOR REUSE. RAISE CARPET TUFT BY STEAM CLEANING AREAS WHERE PARTITION WALLS WERE REMOVED. REPAIR, PATCH AND PREPARE READY FOR PAINTING, GYPSUM WALLBOARD DAMAGED BY THE WORK OF THIS CONTRACT. PAINT AND BLEND TO SEAMLESS CONDITION. WHEN SEAMLESS CONDITION CANNOT BE ATTAINED AS DETERMINED BY THE CONSTRUCTION MANAGER, PAINT ENTIRE WALL SURFACE. IF EXISTING SOUTH WALL OF STORAGE ROOM IS NOT ALIGNED WITH EXISTING SOUTH WALL OF CONFERENCE ROOM, INSTALL FABRIC COVERED PANELS FROM DEMOLITION AREA ON STORAGE ROOM SOUTH WALL TO ALIGN WALL. 5. SEE DETAIL 8 /A200 FOR ALL WALL PENETRATIONS. 6. ALL EXISTING WALLS AND COLUMN ENCLOSURES IN TENANT SPACE SHALL BE TAPED, FINISHED AND PAINTED. PROVIDE METAL COVER BEAD AT ALL CORNERS. 12. REPAIR PARTITION, CEILING AND FLOOR SYSTEMS AND FINISHES DUE TO REMOVAL OF MECHANICAL AND ELECTRICAL WORK SO THAT PARTITION, CEILING AND FLOOR SYSTEMS ARE RETURNED TO FULL CAPACITY OF SYSTEM AND TO SEAMLESS CONDITION. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS. NEW DOOR 13H4 TO MATCH EXISTING DOOR 1114. DOOR AND HARDWARE TO MATCH EXISTING EXCEPT FOR HARDWARE. SEE SHEET A350 FOR DOOR AND ROOM FINISH SCHEDULES, AND SHEET A500 FOR DOOR /WALL DETAILS. REMOVE ARTWORK /POSTERS PRIOR TO THE START OF WORK. REINSTALL BY DIRECTION OF THE CONSTRUCTION MANAGER. is RELOCATE THE EXIT SIGN TO THE INSIDE OF THE CORRIDOR AS INDICATED. KEY PLAN NO SCALE 5 0 5 10 15 20 190A0111 BERL/10.14.99/14:21 1/8"=1'-0" FEET BE &C ENGINEERS Dp LJ 10.11 .99 Sri REVISION BY APPROVED DATE SAM REVISION BY APPROVED DATE ®off //� /fir FACILITIES DEPARTMENT ❑ AUBURN, ❑ BE LLEVUE, ❑ EVERETT, ❑ KENT, ❑ SEATTLE, WA. 98002 WA. 98007 WA. 98201 WA. 98031 WA. 98124 _ zoc '' Ill;" m `- dr erirreCl \ j / ki / /, Cr Vr ARCHITECTURAL " ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION Is APPROVED DRAWN BY DATE SUBTRLE EAST FIRST FLOOR PLAN LAST RDAS. SYMBOL DATE A ENCLOSE HALLWAY ( #K00899) RBB BC 6.29.96 C HE CKED SHEET 1 A 1 B ADD DOOR (NO2125 -000) RBB PSV 0.1 .99 APPROVED BY DEPT DATE R TITLE BLDG. 7 -68.1 MASTER COL F -0/1 -7 TUKWILA :: PROVED JOB NO. 91090 DWG NO. 7.6B -1A10 EAST FIRST FLOOR PLAN CONFERENCE CONFERENCE 1114 REMOVE EXISTING DOOR CLOSER. FILL HOLES IN DOOR AND FRAME WITH MATCHING PUTTY. DELIVER CLOSER TO CONSTRUCTION MANAGEMENT. NEW DOOR AND RELITE. SEE DETAIL 10 ON SHEET A503. FOR HARDWARE SEE SHEET A350 NEW DEMOUNTABLE WALL. FINISH TO MATCH ADJACENT WALLS. EXISTING CLOSER TO BE RELOCATED TO NEW DOOR. t:ec 0390 LEGEND OFFICE K21A5> GENERAL NOTES EXISTING CONSTRUCTION FIRE RATED G.W.B. PARTITION DEMOUNTABLE PARTITION ROOM NUMBER DOOR NUMBER 1. ALL DIMENSIONS TO FACE OF STUDS,FACE OF EXISTING FINISH AND CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED. 2. ALL DEMOUNTABLE PARTITIONS AND G.W.B. PARTITIONS SHALL BE CENTERED ON COLUMN LINES, WINDOW MULLIONS OR COLUMN ENCLOSURES UNLESS OTHERWISE NOTED. > REMOVE EXISTING DEMOUNTABLE PARTITION WALL COMPLETE. SAVE PANELS FOR REUSE. RAISE CARPET TUFT BY STEAM CLEANING AREAS WHERE PARTITION WALLS WERE REMOVED. REPAIR, PATCH AND PREPARE READY FOR PAINTING, GYPSUM WALLBOARD DAMAGED BY THE WORK OF THIS CONTRACT. PAINT AND BLEND TO SEAMLESS CONDITION. WHEN SEAMLESS CONDITION CANNOT BE ATTAINED AS DETERMINED BY THE CONSTRUCTION MANAGER, PAINT ENTIRE WALL SURFACE. IF EXISTING SOUTH WALL OF STORAGE ROOM IS NOT ALIGNED WITH EXISTING SOUTH WALL OF CONFERENCE ROOM, INSTALL FABRIC COVERED PANELS FROM DEMOLITION AREA ON STORAGE ROOM SOUTH WALL TO ALIGN WALL. 5. SEE DETAIL 8 /A200 FOR ALL WALL PENETRATIONS. 6. ALL EXISTING WALLS AND COLUMN ENCLOSURES IN TENANT SPACE SHALL BE TAPED, FINISHED AND PAINTED. PROVIDE METAL COVER BEAD AT ALL CORNERS. 12. REPAIR PARTITION, CEILING AND FLOOR SYSTEMS AND FINISHES DUE TO REMOVAL OF MECHANICAL AND ELECTRICAL WORK SO THAT PARTITION, CEILING AND FLOOR SYSTEMS ARE RETURNED TO FULL CAPACITY OF SYSTEM AND TO SEAMLESS CONDITION. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS. NEW DOOR 13H4 TO MATCH EXISTING DOOR 1114. DOOR AND HARDWARE TO MATCH EXISTING EXCEPT FOR HARDWARE. SEE SHEET A350 FOR DOOR AND ROOM FINISH SCHEDULES, AND SHEET A500 FOR DOOR /WALL DETAILS. REMOVE ARTWORK /POSTERS PRIOR TO THE START OF WORK. REINSTALL BY DIRECTION OF THE CONSTRUCTION MANAGER. is RELOCATE THE EXIT SIGN TO THE INSIDE OF THE CORRIDOR AS INDICATED. KEY PLAN NO SCALE 5 0 5 10 15 20 190A0111 BERL/10.14.99/14:21 DOOR SCHEDULE DOOR DOOR SIZE TYPE THKNS MAT FINISH FRAME FRAME RATING OUP CLOSER NOTES SECOND FLOOR 2'x4' ACOUSTICAL CEILING TILE 11 3/4" D -1 1 3/4" ® M -1 F -1 FR -1 ®MIN • B -1 21A4 21A5 3'- 0 "X8' -4" EA 3'- 0 "X8' -4" FABRIC COVERED TACKABLE DEMOUNTABLE PANELS F -1 FR -1 F -1 - 2 • NEW CARPET 23A5 3'- 0 "X8' -4" D -1 1 3/4" M -1 F -1 FR -1 F -1 20 MIN 17 • 24A5 IMII 2'- 0 "X7' -O" 2 EA 3'- 0 "X8' -4" 3'-0"X8'-4" D -2 10111=31® 11311111=1® EIMEEMIMI ®� U EIMINII® M11131211111111111111 1 3/8" 1 3/4" M -1 L5I• ®® ® ® alli M -1 M - 1 M -1 M -1 F -1 •1113111 ®311 ®� WM= ®IRIII®ECEIMI© ®Eig � ® ®0®Earmin F -1 FR -3 1 FR -1 FR -1 FR -1 FR -1 FR -1 F -1 F -2 F -1 F -1 FMI ® 1111111111113121•011111111:111 F -1 - 0 0 2D MIN 20 MIN 0 - 13 4 ©_ ©0 ©0 ©_ ©M 6 _ IEMI 21B4 3'-0"X8'-4" 3'- 0 "X8' -4" EDE ® 3 - 0 "X8' -4" 3 - 0"X8' -4" 3'- 0 "X8' -4" 23C5 3'- 0 "X8' -4" 21C7 3'- 0 "X8' -4" 3'- 0 "X8' -4" 1 D -1 D -1 D -1 mum MEM D -1 1 3/4' 1 3/4 1 3/4" 1 3/4" 1 3/4 F -1 F -1 F -1 - - 20 MIN 6 6 17 . 1.1 3'- 0 "X8' -4" 21D4 2204 3'- 0 "X8' -4" 3'- 0 "X8' -4" FR -1 FR -1 FR -1 F -1 20 MIN Erammg - 17 6 3'- 0 "X8' -4" F -1 F -1 3'- 0 "X8' -4" SEE NOTES 5, 6 &7 206 3'- 0 "X8' -4" 2206 3'- 0 "X8' -4" D -1 1 3/4" M -1 F -1 FR -1 F -1 - 4 ■ 21D7 3'- 0 "X8' -4" D -1 1 3/4" M -1 F -1 FR -1 F -1 - 6 2207 3' 0 "(8' - 4" D -1 1 3/4" M -1 F -1 FR -1 F -1 - 6 21E5 3'- 0 "X8' -4" EA D -3 1 3/4 M -1 F -1 FR -5 F -1 20 MIN 9 • 21E6 3'-0"X8'-4" EA D -4 1 3/4" M -2 F -2 - F -2 20 MIN 8 • SEE NOTE 7 21F5 3'- 0 "X8' -4" D -1 1 3/4 M -1, F -1 - F -2 20 MIN 16 • SEE NOTES 4 & 6 22F5 3'- 0 "X8' -4" D -1 EIIII111111111® D -1 1 3/4" 1 3/4' M -1 M -1 '', F-1 F -1 F -1 FR -4 FR -11 F -1 ®ECEIII® F -1 20 MIN 3 15 ' • 23F5 3'- 0 "X8' -4" 24F5 3'-0"X8'74" � 21F6 3- 0"X8' - 4" D -1 1 3/4 ° M -1 ' F -1 FR -1 F -1 20 MIN 10 6 21F7 3- 0 "X8' -4" D -1 1 3/4 M -1 F -1 FR -4 F -1 20 MIN 7 22F7 3'-0"X8'-4" D -1 D -1 D -1 D -1 1 3/4 IIIMIE111111=11131111 1 3/4" M -1 ®® ®® M -1 F -1 F -1 FR -4 FR -2 FR -1 FR -1 F -1 F -1 11E11 •00_ F -1 20 MIN MillE111111111 20 MIN 7 ®0 3 • . 3 0'X8' -4" 22G3 3'-0"X8'- 4" 23G3 • 3'- 0'X8' -4" 111111I 21G4 3 0'X8' -4" 22G4 2'-0"X7'-0" EA D -2 1 3/8" M -1 F -1 FR -3 F -1 - 13 3'-0"X8'-4" D -1 EgImm® D -1 1 3/4" 1 3/4" M -1 M -1 F -1 ®0 F -1 FR -1 FR -1 F -2 F -2 F -1 - Eco0 -- 4 4 24G5 3'-0"X 8 " -4" EA 3'- 0 "58' -4" SEE NOTE 7 2565 2'- 0 "x7' -0" 2 EA. D -2 1 3/8" M -1 F -1 FR -3 F -1 -- 13 21G7 3'- 0 "X8' -4" 131111331w �� D -1 1 3/4" M -1 . F -1 F -1 FR -4 FR -4 FR -1 ® F -1 F -1 20 MIN 0 m 22G7 3'- 0 "X8' -4" 20 MIN - ® 22H2 3'- 0 "X8' -4" 3'- 0 "X8' -4" D -1 1 3/4" M -1 F -1 FR -1 F -1 - 211-14 2'- 0 "X7' -0" 2 EA D -2 1 3/8 M -1 F -1 FR -3 F -1 - 13 22H4 2'- 0 "X7' -0" 2 EA D -2 1 3/8" M -1 F -1 FR -3 iggin® - F -1 F -2 - - 20 MIN 13 5 8 22H5 3'- 0 "X8' -4" D -1 1 3/4" mEss 1 3/4" 1 3/4" 1 3/4" 1 3/4" M -1 M -2 F -1 F -2 21H5 ERN 3' -0 "X 8 " -4" EA 3'- 0 "58' -4" D -4 mum D -1' D -1 D -1 D -1 SEE NOTE 7 M -1 M -1 ®® ® M -1 F -1 ®nsi F -1 F -1 FR -1 FR -1 F -1 F -1 F -1 20 MIN ®0 11 6 ® 3'- 0"X8' -4" ® 3'- 0 "X8' -4" 3'- 0 "58' -4" FR -1, FR -1', F -1 F -1 6 3'- 0 "X8' -4" ® 3'- 0 "X8' - D -1 no MEM 1 ' 1 3/4" 1 3/4" 1 3/4" 1 3/4" M -1 M -1 F -1 FR -1 FR -1 F -1 F -1 3'- 0 "X8' -4" Ego 3'- 0 "X8' -4" M -1 ® 11111111111111111,11111111111111111=1 Egg F -1 ®ME®a ®EM®MEll 6 6 6 2235 3'- 0 "X8' -4" 21 J5 3'- 0 "58' -4" IMIIIIIIMIIIIIIMIIIIMMII _ KEY MATERIAL I C -1 2'x4' ACOUSTICAL CEILING TILE GYPSUM WALLBOARD; LOW SHEEN LATEX PAINT W -1 GYPSUM WALLBOARD, PAINTED V -1 VINYL COVERED GYPSUM WALLBOARD PANELS B -1 2 1/2" RESILIENT BASE /4" ® CABINETS FT -1 FABRIC COVERED TACKABLE DEMOUNTABLE PANELS FT -2 FABRIC COVERED TACKABLE ACOUSTICAL PANELS FL -1 NEW CARPET FL -2 EXISTING CARPET FL -3 SEALED CONCRETE FL -4 EXISTING CONCRETE FL -5 RESILIENT FLOORING FL -6 NEW CARPET BORDER sYu A D 3' -0 "X 8 " -4 EA 3' -0 "X 8 " -4" 3'- "X ; " -4 " EA ISTIYG SEE NOTE 2 SEE NOTES 1,2 FMS F OO R HARDWARE NOTES GROUP 5 2 PR. HINGES BB1279 4 1/2 X 4 1/2 US26 HAGER 1 EA. LOCKSET 5408PB US26 YALE 1 EA. DOORSTOP 50C US26 GLYNN - JOHNSON GROUP 20 1 CLOSER TO MATCH EXISTING ALL OTHER HARDWARE TO REMAIN. REVISION RECORD DRAWING MOVE DOOR (1300816) ENCLOSE HALLWAY (1/K00899) NEW OFFICES /CONF. RM. (#L00622) ADD DOOR BY JFP RB RBB RBB RBB APPROVED RBB BC MW BC REM PSV DOTE 7.15.92 9.29.95 9.26.96 02.14.97 10.11.99 GROUP 21 2 PR. HINGES BB1279 4 1/2 X 4 1/2 US26 HAGER 1 EA. LOCKSET 5408PB US26 YALE 1 EA. DOOR STOP 50C US26 GLYNN- JOHNSON 1 EA. DOOR CLOSER - FROM DOOR 11 G6 1 EA. SMOKE SEAL S88D PEMKO SPA REVISION APPROVED DATE DOOR TYPES FLUSH D -1 FLUSH M -1 WOOD VENEER M -2 HOLLOW METAL TYPES D -2 F -1 VARNISH F -2 PAINT ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98007 BOEZAI ❑ EVERETT, WA. 98201 FACILITIES DEPARTMENT ❑ KENT, WA. 98031 ® TUKWILA, WA. 98188 ❑ RENTON, WA. 98055 ❑ SEATTLE, WA. 98124 D -3 AND D -4 FLUSH DOOR MATERIAL TYPICAL DOOR AND FRAME NOTES 1. SEE SHEET A500 FOR TYPICAL DOOR FRAMING DETAILS. 2. ALL HARDWARE SHALL COMPLY WITH WASHINGTON BARRIER FREE CODE. 3. DOOR TYPE D -4 IS BY THE "TOTAL DOOR" MFR 4. EXISTING STEEL JAMBS 5. NOT USED 6. RELOCATED EXISTING DOOR 7 ALL JAMBS & HARDWARE BY DOOR MFR. ROOM FINISH LEGEND ROOM FINISH NOTES 1.) ALL ACOUSTICAL CEILING TILE & CEILING GRID SUPPLIED BY, OWNER AND INSTALLED BY CONTACTOR 2.) SEE SHT A200 FOR WALL TYPES 3.) ALL WALL COVERINGS SHALL HAVE A FLAME SPREAD RATING OF 25' OR LESS 4.) ALL EXISTING GWB WALLS AND COLUMN ENCLOSURES SHALL BE TAPED, FINISHED AND PAINTED. 5.) NEW WALLS AND BASE TO MATCH EXISTING. 6.) NEW WALLS AND BASE TO MATCH EXISTING. rFGISTERED ARCHITECT L/ 4 ^'IiIFRT IT. DERLIEN STATE OF IYASIINIGTON 21C7 22C7 IEEE 21E6 22F5 EMI 25G5 21G7 21H2 22H2 21H4 22H4 22H5 21H5 21H6 2113 2115 2132 22J2 2133 22J3 2134 2234 23J4 2135 22J5 STORAGE OFFICE CLASSROOM CONFERENCE FL- FL- 5 23A5 24A5 2184 2165 24C5 2106 22D4 2304 24D4 2106 21 F7 22F7 COPY ROOM DATA ROOM CORRIDOR OFFICE OFFICE OFFICE OFFICE CLASSROOM LIBRARY CLASSROOM CORRIDOR OFFICE STORAGE OFFICE OFFICE RECEPTION OFFICE COPY ROOM STORAGE OFFICE OFFICE OFFICE STORAGE OFFICE CORRIDOR CLOSET FL -2 FL -1 EMI KIIIIIIMON FL -1 11:111® FL-1 ®M ® �® � i SEEM -1 iM B - 1 M ill B -1 V -1 B -1 V -1 B -1 W -1 FL -1 FL -1 FL -1 FL -1 FL -1 FL -1 FL -1 con ®I ®11:1101 FL -1 FL -1 FL -1 FL -1 FL -1 FL -1 FL -1 B -1 V -1 V -1 V -1 B -1 B -1 8 -1 B -1 W -1 B -1 B -1 B -1 B -1 B -1 B -1 V -1 V -1W -1 W -1 W -1V -1 V -1 W -1 V -1 W -1 W -1 W -1 V -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B - 1 B -1 B -1 B- B- I B -1 B -1 B -1 B -1 8 -1 B -1 B- B-1 B -1 B -1 B - i B -1 B B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 W -1 W -1 W -1 V- V-1 W -1 W -1 W- V -1 V -1 V -1 FT -1 W -1 W -1 W -1 - i W -1 V -1 W -1 V -1 W -1 W -1 W -1 W -1 W- W -1 W -1 FT1FT2 W -1 W -1 V -1 W -1 W -1 W -1 W- W- 1 V -1 W -1 V -1 V -1 V -1 W -1 W -1 B -1 B -1 8 - 1 B -1 B -1 B -1 B -1 FL -1 FL -1 _ B -1 W -1 W -1 8 -1 RI V -1 B -1 Ii L I 1121111132111171111110111111111111 1121111132111171111110111111111111 ® 1 ® B - 1 L B -1 E 113211® B -1 ®. ® B -1 ®11:11811® 11351111111111111111111591 W - 1 V -1W -1 ROOM 13H4 ROOM NAME SECOND FLOOR 21A4 CLASSROOM 21A5 22A5 SERVICE APPROVED BY BREAK ROOM CORRIDOR CLOSET STOCK ROOM CORRIDOR STORAGE CLOSET OFFICE OFFICE OFFICE OFFICE CLOSET CLOSET OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE FIRST FLOOR CORRIDOR ACCEPTABILITY DRAWN T RI CH THIS DESIGN AND /OR SPECIFICATION IS APPROVED DEPT. DATE L .WO9 E APP RO G FLOOR FL1 &FL6 B -1 W -1V - ®� B -1 W -1 WE ® _�_I�_ WI �® ®ui®® � U. W -1 W -1 •3111111111111121M11 •3111111111111121M11 @ -1 ®U.U 112111&11111111111131111111:111 112111&11111111111131111111:111 112111&11111111111131111111:111 ®ME _ 11111111311111111111M- ® W -1 FL-1 FL -1 U. W -1 B -1 V -1 W -1 B -1 W -1 FL -1 8 -1 FL -1 B -1 FL -1 B -1 FL -1 B -1 FL -1 B -1 FL -2 FL -1 FL -1 FL -1 FL -1 DATE M fE QEY 5.6.91 ROOM FINISH SCHEDULE NORTH BASE I WALL B -1 B -1 B -1 SDBRTLE V1 &W1 B -1 V -1 B -1 W -1 V -1 B -1 V -1 V -1 B -1 V -1 B -1 W -1 V -1 EAST BASE I WALL B -1 B -1 W -1 V -1 BLDG. 7 -68.2 COL SCHEDULES SOUTH BASE I WALL B -1 V -1 B -1 V -1 B -1 V -1 V -1 C -1 8' -10 "AFF C -1 8' -10 "AFF C -1 8' -0 "AFF C -2 8' -10 "AFF B -1 W -1 C -2 8' -10 "AFF B -1 W -1 C -1 8' -10 "AFF B -1 W -1V -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 W -1V -1 C -1 8' -10 "AFF 6 B -1 W -1 C -1 8' -10 "AFF B -1 W -1V -1 C -1 8' -10 "AFF B -1 W -1 C -2 8' -10 "AFF B -1 W -1V -1 C -1 8' -10 "AFF B -1 W -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 W -1 C -1 8' -10 " AFF B -1 V -1 C -1 8' -10 "AFF B -1 W -1 C -2 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 "AFF B -1 V -1 C -1 8' -10 'AFF B -1 W -1 C -2 8' -6 "AFF B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B -1 B - 1 B - 1 B -1 B -1 B -1 B -1 B - 1 B- B- B- B -1 tq 4O3o I I I Y A NOV .O ARCHITECTURAL MASTER WEST BASE I WALL B -1 B -1 B -1 B -1 1 V- FT -1 W -1 W -1 W -1 V -1 W -1 W -1 W -1' C -1 8' -10 "AFF V -1W -1 C -1 8' -10 "AFF W -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF W -1 C -1 8' -10 "AFF W -1 C -2 8' -10 "AFF W -1 C -1 8' -10 "AFF W -1 C -2 8' -6 "AFF W -1 C -2 8' -6 "AFF FT -2 C -1 8' -10 "AFF W -1 C -2 8' -6 "AFF V -1 C -1 8' -10 "AFF W -1 C -2 8' -6 "AFF V -1 C - 8' -10 "AFF V -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF W -1 C -2 8' -6 "AFF W -1 C -2 8' -6 "AFF V -1 C -1 8' -10 "AFF 6 W -1 C -1 8' -10 "AFF W -1 C -1 6' -10 "AFF 6 W -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF V -1 C -1 8' -10 "AFF 8' -10 "AFF C -1 8' -10 "AFF C -1 8' -10 "AFF V -1 C - 8' -10 "AFF V -1 C - 8' -10 "AFF V -1 C -1 8' -10 "AFF V -1 C - 8' -10 "AFF TUKWILA CEILING MAT'L I HEIGHT C -1 8' -10 "AFF OCT 'EI [I+TTA SHEET A350 J08 NO. 91090 DWG NO. 7.68 -A350 NOTES 190A350N BERL/10.14.99/14:26 68 -A503 BERL/10.14.99/14:32 EXISTING RELITE AND TRIM 8 1/2' 1' -7" i-8 1/2" EXISTING WINDOW EXIST ALUMINUM MULLION EXIST. JOG AT CEILING FOGONAL BRACE BEYOND. - EXISTING 1 HR WALL WITH 2 1/2 STUDS AND 5/8" \ , TYPE X GWB BOTH SIDES. EXISTING CEILING WITH 6" JOISTS AND 5/8' TYPE X GWB BOTH SIDES. FACE OF WALL BEYOND. ATTACH NEW 6" RIM JOIST TO EXIS ING. NEW 6" JOISTS AND 5/8" TYPE X GWB CEILING. NEW 2 1/2" 1 HR WALL TO MATCH EXISTING NEW DOOR. PROVIDE SAFETY GLASING AT NEW ENTRY DOORS. DOORS TO BE 20 MIN. / \ / I NEW 5/8" GWB AT BOTH SIDES I � BLDG. STD BLINDS 1/4" FOAM GASKET I ri 7 �- NEW 2 1/2" STUD FRAMING ,wi EXIST'G ALUM SILL CEILING RUNNER AT WALL ..... END OF EXISTING WALL DEMOUNTABLE PARTITION SYSTEM 4 1/4" DETAIL AT MULLION 3 NEW WALL AT RELITE 1 ELEVATION AT ENTRY DOORS n SECTION AT CORRIDOR 1A10 A502 SCALE: 1/2" = 1' -0" 2A10 A503 SCALE: 1 1/2" = 1' -0° 2A10 A503 4 SCALE: 1/2" = 1' -0" 2A10 A503 1/2„ ALL WOOD TRIM AND FRAME TO BE OAK TO MATCH EXIST. 2 1/2'` ALIGN WITH FACE OF COLUMN ENCLOSURE. PROVIDE SAFETY GLASING AT RECITE. 6" HEADER 5/8., GWB 5/8 -, 5/8'- FRAMING. 3/4" x 2 1/2" TRIM In i II _ / / / A503 A503 REMOVE EXISTING WALL AS REQUIRED 1 -7" l�� DEMOUNTABLE WALL � � / I�4I * _ 4 4 1 � I �III GG r� ' � �- %►�" � 'a� � 11 % I � IAt \ \VNZ �� ' POC KET DOOR GUIDE TO CONSTRUCT NEW 1 HR ENCLOSURE. REPLACE AT ROOM SIDE. IM ` \ \ EXTEND GWB TO FACE OF EXISTING DETAIL AT RECESS GLAZING STOPS 5/8" TRIM 1/8" SAFETY GLAZING 1/2" PLYWOOD TYPICAL DOOR FRAME ELEVATION AT RELITE o I -- 5/8" OAK TRIM T v-7" i DOOR TO MATCH EXIST. SOLID CORE DETAIL AT POCKET DOOR 7 : ELEVATION AT RELITE SCALE: 1/2" = 1' -0" 2A10 A 503 SCALE: 1/4" = 1' -0" A503 A503 SCALE: 3" = 1' -0° A501 A503 SCALE: 1/2" = 1' -0" 13 T FIT TRIM TO FACE OF EXIST! G COL. PROVIDE SAFETY GLAZING A RELITE. :.,:,v FIT TRIM TO FACE OF EXISTING COL. PROVIDE SAFETY GLAZING AT RELITE. ■ 0 3 1. I r:, Iy 71 In(f �. -. III! A503 A503 IiI�I 4503 A503 a o I I oo o .� ELEVATION AT RELITE E LE ATION AT RELITE SCALE: 1/2" = 1' -0" 2A10 A503 ... SCALE: 1/2" = 1' -0" 1A1 A50 BE &C ENGINEERS C H . ) 99 1 Sri - REVISION BY APPROVED DATE S YM REVISI•. B! - APPROY D DATE - � UBURN, WA. 98002 ❑ B ELLEVUE BELLEVUE, WA 98007 DRAWN BY DAM SMIELE DETAILS ITLE ARCHITECTURAL MASTER LAST REVISION SHEET sr�+BOL .99 DATE RELOCATE DOOR (# L00060 -1 RBB REM 2.17.97 zBRS RCGISTERED "`j \ H: TEC T ACCEPTABILITY THIS DESIGN I ON I APPRO AND /OR SP f CIFIC4T D.SPRINGER {�j�,�y. J ,P ETRICH A BUILD OFFICES (0M04061) RBB JTM 10.07.98 ®®E /ACC ❑ EVERETT, WA: 98201 A503 JOB N°. 91090 B ADD RELITE RBB JTM 102298 FACILITIES DEPARTMENT 0 KENT WA. 98031 % � , Q`' RO D. SH srnr E Of uFwnsliINGT wcroN APPROVED 8Y DEPT, DATE e;► mom APPR C ADD DOOR (002125 -000) RBB PSV 10.11.99 TU KWILA, WA. 98188' ❑ RENTON, WA. 98055 ❑ SEATTLE, WA. 98124 5.9.91 B 7 6 BLDG. -8.2 COL TUKWILA °WG N0 7.68 -A503 68 -A503 BERL/10.14.99/14:32